Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “IONIZATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

Experimental and theoretical study of the gas-phase interaction between ionized nitrile sulfides and pyridine.

The gas-phase reactivity of ionized nitrile sulfides, R-C[triple bond]N(+)-S*, towards neutral pyridine was studied both experimentally (six sector hybrid mass spectrometer) and theoretically (density functional theory and Møller-Plesset ab initio calculations). An ionized sulfur atom transfer and a cycloaddition process respectively yielding ionized pyridine N-thioxide and a thiazolopyridinium cation were observed. Whereas the very efficient S*+ transfer reaction probably involves the intermediacy of several ion-molecule complexes, the thiazolopyridinium ion formation is likely to be initiated by an electrophilic attack of the R-C[triple bond]N(+)-S* ion on the nitrogen atom of pyridine; the resulting intermediate then undergo an intramolecular substitution of an alpha-hydrogen atom by the sulfur atom.

Journal Article↗

[Pulmonary and cardiac late effects of ionizing radiations alone or combined with chemotherapy].

High doses of ionizing radiation (> 40 Gy) cause severe lung fibrosis in approximately 5% of the cases. There is a twofold increase when chemotherapy is added to ionizing radiation. Lung fibrosis is due to the destruction of lung tissue by ionizing radiation but also to various cytokine effects (PDGF-beta, TGF-beta). Only a minority of patients (approximately 10%) with abnormal X-rays will experience clinical symptoms. The most important radiobiological parameters which accounts for pulmonary tolerance is the fraction size. Irradiation of the heart begets multifarious late sequelae which are often left unrecognized. Chronic pericarditis affects approximately 5% of the patients when the irradiation dose exceeds 40 Gy. Coronary artery disease can be diagnosed in 5 to 10% of the patients. This late complication is more likely to occur if the patient was young at the time of the irradiation or if other risk factors are associated. Valvular defects can be found in 15 to 30% of the patients. However, the mortality rate is very low (0.5%). Finally, conduction defects can also be seen in approximately 5% of the patients. It is very likely that the radiation dose given to the heart should not exceed 30 Gy if late sequelae are to be avoided.

Antineoplastic Combined Chemotherapy Protocols↗

Application of gas chromatography-surface ionization organic mass spectrometry to forensic toxicology.

Surface ionization (SI), which consists in the formation of positive and negative ions along the course of thermal desorption of particles from a solid surface, was first applied as a detector for gas chromatography (GC), GC-surface ionization detection (SID); we developed many new sensitive methods for the determination of abused and other drugs by GC-SID. Recently, Fujii has devised a combination of SI and a quadrupole mass spectrometer and named this system a surface ionization organic mass spectrometer (SIOMS), which is highly selective and sensitive for organic compounds containing tertiary amino groups. We have tried to apply this mass spectrometer to forensic toxicological study; so far we have succeeded in determining important drugs-of-abuse and toxic compounds, such as phencyclidine (PCP), pethidine, pentazocine, MPTP and its derivatives from human body fluids with high sensitivity and selectivity. In this review, we describe our recent studies on the application of GC-SIOMS to forensic toxicology.

Forensic Medicine↗

Optimization of protein precipitation based upon effectiveness of protein removal and ionization effect in liquid chromatography-tandem mass spectrometry.

Four categories of protein precipitation techniques (organic solvent, acid, salt and metal ion) were tested in plasma using spectrophotometry to assess protein removal efficiency across a range of volumes, species and lots. Acetonitrile, trichloroacetic acid (TCA) and zinc sulfate were found to be optimal at removing protein in their categories (>96, 92 and 91% protein precipitation efficiency at a 2:1 ratio of precipitant to plasma, respectively). A post-column infusion LC-MS/MS system was used to assess ionization effect of a protein-bound drug caused by the endogenous components remaining after using various protein precipitants. The extent of ionization effect varied with mobile phase (-20 to 93%), protein precipitant (0.3-86%), but only slightly with species (86-93%). The optimal bioanalytical methodologies for removal of plasma proteins and minimal ionization effect for the probe molecule in positive ion turboionspray LC-MS/MS involve the use of TCA for precipitation with mobile phases consisting of either pure organic solvents (methanol:water or acetonitrile:water) or precipitation with all of the mass spectrometer compatible precipitants evaluated with a methanol:aqueous 0.1% formic acid mobile phase.

Animals↗

Ionizing radiation attracts soil fungi.

During the last 15 years, about 2000 strains of 200 species of 98 genera of fungi have been isolated from around the Chernobyl Atomic Energy Station. Many of these microfungi are capable of growing into and decomposing 'hot particles'; carbon based radioactive graphite from the reactor and there are suggestions that some fungi actively direct their growth toward sources of radioactivity, possibly attracted to the carbon skeleton of these structures. In our experiments, we eliminated the confounding effects of carbon as a fungal resource, by developing experimental protocols that expose fungal spores and their germinating hyphae to directional sources of ionizing radiation allowing us to measure fungal response to ionizing radiation per se. We show that both beta and gamma radiation promote directional growth of hyphae towards the source of ionizing radiation.

Beta Particles↗

Electron ionization cross sections for atomic subshells.

Ionization of atoms is the first step in many analytical procedures. The cross section for ionizing a particular atomic shell is essential for calculating the magnitude of analytical signals. Calculations using atomic wave functions for various shells of all elements relevant for X-ray microanalysis over a range of electron energies up to 400 keV were performed. The calculations for high energies above threshold can be considerably simplified by using the mathematical form of the Bethe ridge that dominates the scattering in this region. Corrections for exchange at low energies above threshold are incorporated in these calculations. A selection of results showing the effects of different approximations on ionization cross sections for K, L, and M shells is presented.

Electron Probe Microanalysis↗

High-pressure ion source combined with an in-axis ion trap mass spectrometer. 2. Application of selective low-pressure negative ion chemical ionization

Negative ion chemical ionization was carried out using a quadrupole ion trap mass spectrometer with selected reactant negative ions, primarily injected from a homemade dual EI/CI external ion source. Hence, selective ion/molecule reactions were provided according to the reaction time, which induce a greater control over bimolecular ionization mechanisms than in conventional a high-pressure ion source combined with beam instruments, where several competitive ionization processes take place mainly due to source conditions (e.g., temperature, pressure, and repeller). By selecting the reactant ions, ion/molecule reactions were specifically produced (i.e., charge exchange, proton transfer, nucleophilic substitution, and/or alpha-beta elimination) with several organic target compounds. Gas-phase reactivity of phosphorus- and nitrogen-containing compounds (such as phosphonates as representative for chemical warfare agents and phosphorothionates, phosphorodithionates, and triazines for pesticides) as well as dinitro aromatic compounds (for pesticides) has been explored, in the present work, to ensure further unambiguous detection.

Journal Article↗

Surface ionization organic mass spectrometry of imipramine, desipramine, clomipramine, and lidocaine.

Surface ionization organic mass spectrometry (SIOMS) has been performed on some clinically important drugs (imipramine, desipramine, clomipramine, lidocaine) by using quadrupole mass spectroscopy in which the thermal ion source has a rhenium oxide emitter. The mass spectra were presented, interpreted in a purely empirical way, by means of evidence from previous investigations, and then compared to conventional EI techniques. Sensitivity and selectivity have also been studied, demonstrating that (a) these drug compounds are efficiently surface-ionized, (b) experimental results rationalize the high sensitivity of the surface ionization detector (SID) of gas chromatography (GC) for the examined drugs, and (c) the GC/SIOMS coupling can be used for sensitive and selective detection of the drugs in the serum. An approach to detection of these drugs in serum by GC/SIOMS and GC with SID is described. The characteristics of both methods provide a reliable, sensitive, and selective method, which is needed for low concentration level measurements in complex mixtures.

Clomipramine↗

Effects of anions on the positive ion electrospray ionization mass spectra of peptides and proteins.

Positive ion electrospray ionization mass spectra of polypeptides are usually obtained from solutions that are acidified and therefore contain relatively high concentrations of anions. The present study describes an investigation of the effects of these ubiquitous anions on the positive ion electrospray ionization mass spectra of peptides and proteins. Certain anionic species in the spray solutions were observed to cause a marked decrease in the net average charge of peptide and protein ions in the mass spectra compared to the average charge measured in the absence of these anions. This charge neutralization effect was found to depend solely on the nature of the anionic species and was independent of the source of the anion (acid or salt), with the propensity for neutralization following the order: CCl3COO- > CF3COO- > CH3COO- approximately Cl-. A mechanism for the observed charge reduction effect is proposed that involves two steps. The first step occurs in solution, where an anion pairs with a positively charged basic group on the peptide. The second step occurs during the process of desolvation or in the gas phase, where the ion pair dissociates to yield the neutral acid and the peptide with reduced charge state. The different propensities for charge neutralization of the different anionic species is presumed to reflect the avidity of the anion-peptide interaction. These findings demonstrate that any attempt to correlate the distribution of charge states observed on proteins in the gas phase (by positive ion electrospray ionization mass spectrometry) with the net charge residing on the protein in solution will require that the described anion effect be taken into account. In addition, it appears that some control over the distribution of charge states on peptides and protein ions can be exercised by an appropriate choice of anion in the electrospray solution.

Acetates↗

Prompt fragmentation of disulfide-linked peptides during matrix-assisted laser desorption ionization mass spectrometry.

During the analysis of an Asp-N digest of a recombinant hematopoietic growth factor by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS), we observed pseudomolecular ions corresponding to reduced forms of peptides known to be present only in single disulfide linkages. Chromatographic fractionation of the peptide digest, followed by MALDI-MS and electrospray ionization (ESI) MS, confirmed that the reduced peptides were not present in the map. Fragmentation of the disulfide-linked peptides into their reduced forms occurred upon ionization from different matrices (alpha-cyano-4-hydroxycinnamic acid,2,5-dihydroxybenzoic acid, and in some instances sinapinic acid) but only after increasing the laser fluence to above threshold. Analysis of the disulfide-linked peptide fractions by ESI-MS, before and after mixing and drying with matrix, indicated that the matrix did not cause reduction. In a low-energy tandem mass spectrometric experiment with one of the cystinyl peptides, fragmentation did not occur preferentially at the disulfide bond. The pseudomolecular ions exhibited the same m/z values by MALDI-MS as their chemically reduced counterparts, indicating that they arose due to prompt fragmentation or "in-source decay" rather than "post-source decay". This finding is important for MALDI-MS analysis of peptide maps of proteins and peptide fractions with intact disulfides.

Amino Acid Sequence↗

Determination of iodine in oyster tissue by isotope dilution laser resonance ionization mass spectrometry.

The technique of laser resonance ionization mass spectrometry has been combined with isotope dilution analysis to determine iodine in oyster tissue. The long-lived radioisotope, 129I, was used to spike the samples. Samples were equilibrated with the 129I, wet ashed under controlled conditions, and iodine separated by coprecipitation with silver chloride. The analyte was dried as silver ammonium iodide upon a tantalum filament from which iodine was thermally desorbed in the resonance ionization mass spectrometry instrument. A single-color, two-photon resonant plus one-photon ionization scheme was used to form positive iodine ions. Long-lived iodine signals were achieved from 100 ng of iodine. The precision of 127I/129I measurement has been evaluated by replicate determinations of the spike, the spike calibration samples, and the oyster tissue samples and was 1.0%. Measurement precision among samples was 1.9% for the spike calibration and 1.4% for the oyster tissue. The concentration of iodine determined in SRM 1566a, Oyster Tissue, was 4.44 micrograms/g with an estimate of the overall uncertainty for the analysis of +/- 0.12 microgram/g.

Animals↗

Molecular weight distributions of heavy aromatic petroleum fractions by Ag+ electrospray ionization mass spectrometry.

The ability of electrospray ionization mass spectrometry (ESI MS) to analyze heavy aromatic petroleum fractions using silver nitrate as a reagent compound to form characteristic adduct ions has been examined. The complexation of aromatic compounds containing long alkyl substituents with the silver ion leads to the formation of abundant adduct ions such as [M + Ag]+ and [2M + Ag]+. The concentration of the [2M + Ag]+ ions can be reduced by increasing the sampling cone voltage. Molecular ions and other adduct ions may also be formed depending on the structure of the aromatic molecule. Results obtained from the analysis of representative heavy petroleum fractions and vacuum residues by the Ag+ ESI MS method and conventional ionization methods were in good agreement. The current method extends the applicability of electrospray ionization to the analysis of neutral hydrocarbons in heavy aromatic petroleum fractions. It is simple and compatible with widely available LC/MS instrumentation. The extreme complexity of the Ag

Journal Article↗

Collection of airborne fluorinated organics and analysis by gas chromatography/chemical ionization mass spectrometry.

The ubiquitous detection of perfluorooctane sulfonate (PFOS) in humans and animals has produced a need for sensitive and compound-specific analytical methods to determine the environmental distribution of fluorinated organic contaminants. A suite of potential PFOS precursors (sulfonamides) and fluorotelomer alcohols (FTOHs) were separated by gas chromatography and detected by chemical ionization mass spectrometry (GC/CI-MS). Full-scan spectra were collected in both positive and negative chemical ionization (PCI and NCI, respectively) mode to determine retention time windows and fragmentation patterns. In selected ion monitoring (SIM) mode, instrumental detection limits ranged from 0.2 to 20 pg for individual analytes, depending on ionization mode. PCI mode was preferred for routine analysis because of the simple mass spectra produced, typified by the presence of a major molecular ion [M + H]+. High-volume air samplers collected gaseous and particle-bound fluoroorganics on composite media consisting of XAD-2, polyurethane foam (PUF), and quartz-fiber filters. The combined collection efficiency for individual analytes was 87 to 136% in breakthrough experiments. Application of the method to the analysis of ambient air from urban and rural sites confirmed the presence of six novel fluorinated atmospheric contaminants at picogram per meter3 concentrations. Low concentrations of fluoroorganics were consistently detected in blanks (<4 pg m(-3)); however, this did not prevent confirmation or quantification of environmental concentrations.

Air Pollutants↗

Retention of ionizable compounds on HPLC. 12. The properties of liquid chromatography buffers in acetonitrile-water mobile phases that influence HPLC retention.

The addition of acetonitrile to aqueous buffers to prepare RP HPLC mobile phases changes the buffer properties (pH and buffer capacity). This variation is studied for ace tate, phosphate, phthalate, citrate, and ammonia buffers in acetonitrile-water mixtures up to 60% in acetonitrile (v/v). Equations are proposed to relate pH and buffer capacity change of these buffers to the initial aqueous pH value and to the volume fraction of acetonitrile added. It is demonstrated that the pH change of the buffer depends not only on the initial aqueous pH of the buffer and on the percentage of acetonitrile added but also on the particular buffer used. The proposed equations allow an accurate prediction of this ionization for the studied buffers. Since the retention of acid/base compounds shows a strong dependence of their degree of ionization, the equations are used to predict the change in this ionization with addition of acetonitrile when the RP HPLC mobile phase is prepared. This prediction allows estimation of the retention of an acid/base compound in a particular acetonitrile-water buffered mobile phase.

Journal Article↗

Stacking ionizable analytes in a sample matrix with high salt by a transient moving chemical reaction boundary method in capillary zone electrophoresis.

The paper presents a novel on-line transient moving chemical reaction boundary method (tMCRBM) for simply but efficiently stacking ionizable analytes in high-salt matrix in capillary zone electrophoresis (CZE). The powerful function and stability of the tMCRBM are elucidated with the ionizable test analytes of L-phenylalanine (Phe) and L-tryptophan (Trp) in the matrix with 85.6-165.6 mM sodium ion and further compared with the normal CZE of Phe and Trp samples dissolved in running buffer. The results verify that (1) the on-line tMCRBM mode can evidently increase separation efficiency, peak height, and resolution, (2) with the mode, the analytes in a 28-cm high-salt matrix plug can be stacked successfully and further separated well, (3) the values of relative standard deviation of peak height, peak area, and migrating time range from 3.9% to 6.1%; the results indicate the high stability of the technique of tMCRBM-CZE. The techniques implies obvious potential significance for those ionizable analytes, e.g., protein, peptide, and weak alkaline or acidic compound, in such matrixes as serum, urine, seawater, and wastewater, with high salt, which has a deleterious effect on isotachophoresis (ITP) and especially on electrostacking and field-amplified sample injection (FASI). The mechanism of stacking of zwitterionic analytes in a high-salt matrix by the tMCRBM relies on non-steady-state isoelectric focusing (IEF) but not on transient ITP, electrostacking, and FASI.

Amino Acids↗

Incorporation of a venturi device in electrospray ionization.

Electrospray ionization has grown to be one of the most commonly used ionization techniques for mass spectrometry, and efforts continue to improve its performance. Typically, the sprayer tip must be very close to the entrance orifice of the mass spectrometer in order to maximize the conduction of ions from the sprayer into the mass spectrometer. However, because of space-charge repulsion, most ions never reach the sampling orifice. In this work, an industrial air amplifier, for which the working mechanism is based on venturi and coanda effects, was added between an electrospray ionization source and a time-of-flight mass spectrometer. When a series of reserpine solutions (0.5, 1.0, 5.0, and 10.0 microM) were monitored using mass spectrometry, an over 5-fold increase in m/z 609.3 ion intensity was measured for a separation distance of 14 mm between the electrospray tip and interface capillary inlet, as compared to when the electrospray tip was in its normal position 1 mm in front of the inlet without the amplifier. When a voltage was applied to the air amplifier to further assist in focusing the electrosprayed ions, an approximately 18-fold increase in m/z 609.3 ion intensity was obtained. In addition, a 34-fold reduction in method detection limit was observed.

Journal Article↗

A sample introduction technique for obtaining a multiphoton ionization spectrum using picogram quantities of analyte in supersonic jet spectrometry.

A new sample introduction techniquefor ensuring the safety of a researcher during the measurement of hazardous compounds, such as dioxins, by supersonic jet spectrometry is described. The solution containing the analyte is introduced beneath the nozzle through a narrow capillary with a glass frit at the end, which is formed to vaporize only the solvent and to deposit the analyte. The first laser, that is, the second harmonic emission of a Nd: YAG laser, vaporizes the analyte and entrains it into a supersonic jet. The analyte molecule is ionized by the second laser, that is, an optical parametric oscillator. Ion measurement is achieved by a time-of-flight mass spectrometer. The analyte molecule is localized in the jet, thus permitting the amount of sample to be minimized. The minimum amount of phenol necessary for measurement of a multiphoton ionization spectrum by scanning the wavelength of the ionization laser in the 3-nm range was 180 pg, which is similar to or slightly less than the tolerable daily intake (TDI) of dioxin.

Journal Article↗

Development of LC/MS/MS methods for cocktail dosed Caco-2 samples using atmospheric pressure photoionization and electrospray ionization.

Good reliability of Caco-2 permeability studies requires competent sampling and analytical methods to ensure the comparability of day-to-day experiments. In this work, two n-in-one LC/MS/MS methods based on two different ionization techniques were developed and validated for a group of reference compounds; eight of them are recommended by the Food and Drug Administration (FDA) for the evaluation of oral drug permeability. The performance of a new ionization technique, atmospheric pressure photoionization (APPI), as an interface for quantitative LC/MS analysis was evaluated in comparison to the electrospray ionization (ESI). Generally, the validation parameters, including sensitivity, accuracy, and repeatability, were comparable for the APPI and ESI methods. The main difference was that the linear quantitative range of APPI was 3-4 orders of magnitude (r(2) >/= 0.998) whereas in ESI it was typically 2-3 orders of magnitude (r(2) >/= 0.990). By the APPI and ESI methods, the simultaneous analysis of nine highly heterogeneous compounds was achieved within 5.5-7 min, which leads to significant savings in time and cost of the analyses. The successful validation data indicate the usefulness of both the methods for the rapid and sensitive (LOD values typically </=5 nM) testing of drug transport across the Caco-2 monolayers, and after case-specific modification, the methods enable the permeability screening of new drug candidates. The applicability and reliability of both methods was demonstrated with a real batch of Caco-2 samples, each providing similar values of apparent permeability (P(app)). In addition, the individual permeabilities of the compounds in the cocktail experiments correlated closely to the ones obtained from single-compound experiments.

Journal Article↗