Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

Chemiluminescence detection for hybridization assays on the flow-thru chip, a three-dimensional microchannel biochip.

Chemiluminescence (CL) detection is seldom used in two-dimensional solid support microarray platforms because adequate sensitivity and spatial resolution is difficult to achieve. The three-dimensional ordered microchannels of the Flow-thru Chip increase both the sensitivity and spatial resolution required for quantitative CL measurements on microarrays. Enzyme-catalyzed CL reactions for the detection of hybridizations on microchannel glass were imaged using a CCD camera. Signal uniformity, sensitivity, and dynamic range of the detection method were determined. The relative standard deviation of signal intensities across an array of 64 spots was 8.1%. A detection limit of 250 amol of target with a linear dynamic range of 3 orders of magnitude was obtained for a 3-h assay. Similar to two-color fluorescence measurements, multiple enzyme labels were employed to demonstrate two-channel chemiluminescence. A unique method for measuring the relaxation time of a chemiluminescent species is also described.

Calibration↗

Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device.

Microfabricated lab-on-a-chip devices employing a fully integrated electrochemical (EC) detection system have been developed and evaluated. Both capillary electrophoresis (CE) channels and all CE/EC electrodes were incorporated directly onto glass substrates via traditional microfabrication techniques, including photolithographic patterning, wet chemical etching, DC sputtering, and thermal wafer bonding. Unlike analogous CE/EC devices previously reported, no external electrodes were required, and critical electrode characteristics, including size, shape, and placement on the microchip, were established absolutely by the photolithography process. For the model analytes dopamine and catechol, detection limits in the 4-5 microM range (approximately 200 amol injected) were obtained with the Pt EC electrodes employed here, and devices gave stable analytical performance over months of usage.

Catechols↗

Complementary metal oxide semiconductor cantilever arrays on a single chip: mass-sensitive detection of volatile organic compounds.

The sensing behavior of polymer-coated resonant cantilevers for mass-sensitive detection of volatile organic compounds was investigated. Industrial complementary metal oxide semiconductor (CMOS) technology combined with subsequent CMOS-compatible micromachining was used to fabricate a single-chip system comprising the transducers and all necessary driving and signal-conditioning circuitry. An analytical model was developed to describe the mass-sensing mechanism of polymer-coated resonant cantilevers. The model was validated by measurements of various gaseous analytes. As an exemplary application, the quantitative analysis of a binary mixture using an array of four cantilevers is described. Experimental results are given for the concentration prediction of a mixture of n-octane and toluene. Finally, it was established that the limit of detection achieved with cantilever sensors is comparable to that of other acoustic wave-based gas sensors.

Journal Article↗

Microfabricated electrophoresis chip for bioassay of renal markers.

A novel capillary electrophoresis chip-based detection system for simultaneous measurements of the renal markers creatine, creatinine, p-aminohippuric acid, and uric acid is described. Fluid control is used for mixing the sample with the enzymes creatininase (CA), creatinase (CI), and sarcosine oxidase (SOx) and for separating the neutral hydrogen peroxide end product from the anionic p-aminohippuric and urate species. The 'total' (creatinine and creatine) signal was measured with the running buffer containing all three enzymes, while the creatine signal alone was recorded by mixing the sample with the CI-SOx solution. Creatinine concentrations are measured by comparing the response in the presence and absence of CA. The peroxide product and the oxidizable p-aminohippuric and uric acids are detected electrochemically at a downstream gold-coated thick-film amperometric detector. The four renal markers are readily measured within 5 min, while creatinine/creatine within less than 2 min. Factors influencing the performance, including the level of three enzymes, separation voltage, and detection potential, are optimized. Applicability to urine samples is demonstrated. Such a multianalyte microchip detection device would allow renal function testing to be performed more rapidly, easily, and economically in the point-of-care setting.

Biomarkers↗

Separation high voltage field driven on-chip amperometric detection in capillary electrophoresis.

A new potentiostatless detection scheme for amperometric detection in capillary electrophoresis is presented based on the use of microband array electrodes positioned in the capillary electrophoresis electric field. In the present study, the spatial potential difference in the CE separation high-voltage field was measured using two gold microband electrodes positioned in the proximity of the capillary outlet. The induced potential difference between the two electrodes was recorded as a function of the applied separation high voltage and the dependence of the electrochemically generated current on the high-voltage field, and the concentration of a redox couple (Fe(CN)6(4-)/Fe(CN)6(3-)) was investigated. The results show that plots of the generated current versus the CE separation voltage have the same shape as cyclic voltammograms obtained with the same electrodes in a traditional potentiostatic setup and that the current is proportional to the concentration of the redox couple. As a decoupling device is not needed, the described potentiostatless approach significantly simplifies the instrumental setup for amperometric detection. This approach consequently holds great promise for application in inexpensive portable chip-based CE devices.

Journal Article↗

Microarrays assembled in microfluidic chips fabricated from poly(methyl methacrylate) for the detection of low-abundant DNA mutations.

Low-density arrays were assembled into microfluidic channels hot-embossed in poly(methyl methacrylate) (PMMA) to allow the detection of low-abundant mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. Following spotting, the chip was assembled with a cover plate and the array accessed using microfluidics in order to enhance the kinetics associated with hybridization. The array was configured with zip code sequences (24-mers) that were complementary to sequences present on the target. The hybridization targets were generated using an allele-specific ligase detection reaction (LDR), in which two primers (discriminating primer that carriers the complement base to the mutation being interrogated and a common primer) that flank the point mutation and were ligated joined together) only when the particular mutation was present in the genomic DNA. The discriminating primer contained on its 5'-end the zip code complement (directs the LDR product to the appropriate site of the array), and the common primer carried on its 3' end a fluorescent dye (near-IR dye IRD-800). The coupling chemistry (5'-amine-containing oligonucleotide tethered to PMMA surface) was optimized to maximize the loading level of the zip code oligonucleotide, improve hybridization sensitivity (detection of low-abundant mutant DNAs in high copy numbers of normal sequences), and increase the stability of the linkage chemistry to permit re-interrogation of the array. It was found that microfluidic addressing of the array reduced the hybridization time from 3 h for a conventional array to less than 1 min. In addition, the coupling chemistry allowed reuse of the array > 12 times before noticing significant loss of hybridization signal. The array was used to detect a point mutation in a K-ras oncogene at a level of 1 mutant DNA in 10,000 wild-type sequences.

DNA↗

Amperometric detection of quantal catecholamine secretion from individual cells on micromachined silicon chips.

We have fabricated electrochemical electrodes in picolitersized wells for measuring catecholamine release from individual cells with millisecond resolution. Each well-electrode roughly conforms to the shape of the cell in order to capture a large fraction of released catecholamine with high time resolution. Using this device, we can resolve spikes in amperometric current corresponding to quantal catecholamine release via exocytosis. In addition, we have combined amperometric recording on the chip with patch-clamp recordings of membrane capacitance as an assay of exocytosis. A quantitative comparison of the two methods suggests that a large fraction of catecholamine release is oxidized on the surface of the well-electrode. This technology has applications in cell-based biosensor development, high-throughput screening of drugs, and basic science investigations.

Animals↗

Reusable platforms for high-throughput on-chip temperature gradient assays.

This paper describes a reusable platform that can apply a linear temperature gradient to a lab-on-a-chip device. When a planar microfluidic device with a series of microchannels is placed on top of the platform with the channels perpendicular to the gradient, each channel is held at a discrete temperature. This allows temperature-dependent data for chemical or biochemical species flowed into the device to be obtained in a concurrent fashion. As a demonstration, a melting curve for dsDNA is performed by collecting all the data simultaneously. The gradient is stable enough to easily distinguish between 30-mers where the complement strand contains a single C-A mismatch or a single T-G mismatch or is a perfect match. On the other hand, a temperature gradient can be formed parallel to the direction of flow of the microchannels. This allows the temperature in each channel to vary continuously as the liquid flows downstream. If each microchannel in the array contains a distinct pH value, ionic strength, species concentration, or chemical composition, then a high-throughput two-variable experiment can be performed. We demonstrate this mode of data collection by measuring the fluorescence yield of fluorescein dye molecules in aqueous solution simultaneously as a function of concentration and temperature.

Journal Article↗

Hydrodynamic micromanipulation of individual cells onto patterned attachment sites on biomicroelectromechanical system chips.

We report on a simple methodology to move selected single live cells to a desired location on a flat substrate, such as a patterned biomicroelectromechanical system chip. A macroscopic syringe-and-tube-based hydrodynamic manipulation system is used to achieve controlled cell navigation onto hydrophilic sites for cell attachment. Centimeter-per-second flow velocities generated by the system get downgraded to micrometers-per-second flow at the height of settled cells as a result of viscous flow in the medium. By pushing/pulling two syringes that produce two orthogonal flows, fine manipulation in any horizontal direction is feasible. After attachment of the desired cell(s) onto the selected hydrophilic site, all other unwanted cells are washed away from the surrounding hydrophobic surface with faster flow. This simple methodology is applicable for rapid cell pattern formation with high precision.

Animals↗

Solving the "world-to-chip" interface problem with a microfluidic matrix.

We report an effective solution to the macroscopic/microfluidic interface issue and demonstrate how microfluidics can achieve impressive economies of scale in reducing the complexity of pipetting operations. Using an N x N microfluidic matrix with N = 20, we performed N2 = 400 distinct PCR reactions with only 2N + 1 = 41 pipetting steps, compared with the 3N2 = 1200 steps required with conventional fluid handling. Each vertex of the matrix has a 3-nL reactor, and a single 2-microL aliquot of polymerase is amortized over all 400 independent reactions, thus dramatically reducing sample overhead and minimizing reagent consumption. Beyond PCR, the matrix chip provides a general method to perform chemical and biological experiments with precious reagents in a highly automated fashion.

Journal Article↗

Microfluidic chip for continuous monitoring of hormone secretion from live cells using an electrophoresis-based immunoassay.

A microfluidic device has been developed for the determination of insulin secreted from islets of Langerhans by a capillary electrophoresis competitive immunoassay. Online assays were performed by electrophoretically sampling anti-insulin antibody (Ab), fluorescein isothiocyanate-labeled insulin (FITC-insulin), and insulin from separate reservoirs and allowing them to mix as they traveled through a 4-cm reaction channel heated to 38 degrees C. From the reaction channel, samples were injected onto a 1.5-cm-long electrophoresis channel where the FITC-insulin and FITC-insulin-Ab complex were separated in 5 s using an electric field of 500 V/cm. Detection limits for insulin were 3 nM in this mode of operation. Assays could be collected at 15-s intervals with continuous sampling and online mixing for up to 30 min with no intervention. Relative standard deviation was 2-6% depending on the insulin concentration. Response time to a step change in insulin concentration was 30 s. For live cell monitoring, single islets were placed into a reservoir on the chip and fluid in the immediate vicinity was continuously sampled to detect insulin secretion from the islet. Monitoring of insulin secretion with electropherograms taken at 15-s intervals resolved secretory profiles characteristic of first- and second-phase insulin secretion. The method should be amenable to other cell or tissue types for measurements of release with high temporal resolution.

Animals↗

An electrochemical pumping system for on-chip gradient generation.

Within the context of microfluidic systems, it has been difficult to devise pumping systems that can deliver adequate flow rates at high pressure for applications such as HPLC. An on-chip electrochemical pumping system based on electrolysis that offers certain advantages over designs that utilize electroosmotic driven flow has been fabricated and tested. The pump was fabricated on both silicon and glass substrates using photolithography. The electrolysis electrodes were formed from either platinum or gold, and SU8, an epoxy-based photoresist, was used to form the pump chambers. A glass cover plate and a poly(dimethylsiloxane) (PDMS) gasket were used to seal the chambers. Filling of the chambers was accomplished by using a syringe to inject liquid via filling ports, which were later sealed using a glass cover plate. The current supplied to the electrodes controlled the rate of gas formation and, thus, the resulting fluid flow rate. At low backpressures, flow rates >1 microL/min have been demonstrated using <1 mW of power. Pumping at backpressures as high as 200 psi have been demonstrated, with 20 nL/min having been observed using <4 mW. By integrating two electrochemical pumps with a polymer electrospray nozzle, we have confirmed the successful generation of a solvent gradient via a mass spectrometer.

Coated Materials, Biocompatible↗

Surface modification of the channels of poly(dimethylsiloxane) microfluidic chips with polyacrylamide for fast electrophoretic separations of proteins.

The electrophoresis of proteins was investigated using poly(dimethylsiloxane) (PDMS) microfluidic chips whose surfaces were modified with polyacrylamide through atom-transfer radical polymerization. PDMS microchips were made using a glass replica to mold channels 10 microm high and 30 microm wide, with a T-intersection. The surface modification of the channels involved surface oxidation, followed by the formation of a self-assembled monolayer of benzyl chloride initiators, and then atom-transfer radical polymerization to grow a thin layer of covalently bonded polyacrylamide. The channels filled spontaneously with aqueous buffer due to the hydrophilicity of the coating. The resistance to protein adsorption was studied by open-channel electrophoresis for bovine serum albumin labeled with fluorophor. A plate height of 30 microm, corresponding to an efficiency of 33 000 plates/m, was obtained for field strengths from 18 to 889 V/cm. The lack of dependence of plate height on field strength indicates that there is no detectable contribution to broadening from adsorption. A 2- to 3-fold larger plate height was obtained for electrophoresis in a 50-cm polyacrylamide-coated silica capillary, and the shape of the electropherogram indicated the efficiency is limited by a distribution of species. The commercial capillary exhibited both reversible and irreversible adsorption of protein, whereas the PDMS microchip exhibited neither. A separation of lysozyme and cytochrome c in 35 s was demonstrated for the PDMS microchip.

Acrylic Resins↗

Capillary electrophoresis chips with a sheath-flow supported electrochemical detection system.

Microfabricated capillary electrophoresis chips containing an integrated sheath-flow electrochemical detector are developed with the goal of minimizing the influence of separation voltages on end-column detection while maintaining optimum performance. The microdevice consists of an upper glass wafer carrying the etched separation, injection, and sheath-flow channels and a lower glass wafer on which gold- and silver-plated electrodes have been fabricated. The sheath-flow channels join the end of the separation channel from each side, and gravity-driven flow carries the analytes to the electrochemical detector placed at working distances of 100, 150, 200, and 250 microm from the separation channel exit. The performance of this detector is evaluated using catechol and a detection limit of 4.1 microM obtained at a working distance of 250 microm. Detection of DNA restriction fragments and PCR product sizing is demonstrated using the electroactive intercalating dye, iron phenanthroline. Additionally, an allele-specific, PCR-based single-nucleotide polymorphism typing assay for the C282Y substitution diagnostic for hereditary hemochromatosis is developed and evaluated using ferrocene-labeled primers. This study advances the feasibility of high-speed, high-throughput chemical and genetic analysis using microchip electrochemical detection.

Electrochemistry↗

Cytometry and velocimetry on a microfluidic chip using polyelectrolytic salt bridges.

This paper reports a polyelectrolytic salt bridge-based electrode (PSBE), which is a key embedded unit in a microchip device that can size-selectively count microparticles and measure their velocities. The construction of salt bridges at specific locations within a microfluidic chip enables dc-driven electrical detection to be performed successfully. This is expected to be a competitive alternative to the optical methods currently used in conventional cell sorters. The PSBEs were fabricated by irradiating ultraviolet light over a patterned mask on the parts of interest, which were filled with an aqueous monomer solution containing diallyldimethylammonium chloride. A pair of such PSBEs was easily formed at the two lateral branches perpendicular to the main microchannel and was found to be very useful for dc impedometry. The human blood cells as well as the fluorescent microbeads passing between the two PSBEs produced impedance signals in proportional to their size. The information about the velocity of a microparticle was extracted from a doublet of the dc impedance signals, which were generated when cells or microbeads sequentially passed through two PSBE pairs separated from each other by a fixed distance. The plot of peak amplitude versus velocity of the moving microbeads and cells indicated only a slight correlation between the size and the velocity, which means that the peak amplitude of the dc impedance signals alone can provide information about the size of the cells in a mixture. The experimental results showed a screening rate of over 1000 cells s(-1) and a velocity of the cells of over 100 mm s(-1). Compared with the previously suggested electrical detection system based on metal electrodes, the sensitivity and selectivity in cell detection were remarkably improved. In addition, the detection unit including the operating circuit became innovatively simple and the whole device could be miniaturized.

Blood Cell Count↗

Isoelectric focusing in a poly(dimethylsiloxane) microfluidic chip.

This paper reports the application of ampholyte-based isoelectric focusing in poly(dimethylsiloxane) (PDMS) using methylcellulose (MC) to reduce electroosmosis and peak drift. Although the characteristics of PDMS make it possible to fabricate microfluidic chips using soft lithography, unstable electroosmotic flow (EOF) and cathodic drift are significant problems when this medium is used. This paper demonstrates that EOF is greatly reduced in PDMS by applying a dynamic coat of MC to the channel walls and that higher concentrations of MC can be used to increase the viscosity of the electrode solutions in order to suppress pH gradient drift and reduce "compression"of the pH gradient. To illustrate the effect of MC on performance, several fluorescent proteins were focused in microchip channels 5 microm deep by 300 microm wide by 2 cm long in 3-10 min using broad-range ampholytes at electric field strengths ranging from 25 to 100 V/cm.

Ampholyte Mixtures↗

On-chip native gel electrophoresis-based immunoassays for tetanus antibody and toxin.

By integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device, we have developed a microanalytical platform for performing electrophoresis-based immunoassays. The microfluidic immunoassays are performed by gel electrophoretic separation and quantitation of bound and unbound antibody or antigen. To retain biological activity of proteins and maintain intact immune complexes, nondenaturing polyacrylamide gel electrophoresis conditions were investigated. Both direct (noncompetitive) and competitive immunoassay formats are demonstrated in microchips. A direct immunoassay was developed for detection of tetanus antibodies in buffer as well as diluted serum samples. After an off-chip incubation step, the immunoassay was completed in less than 3 min and the sigmoidal dose-response curve spanned an antibody concentration range from 0.17 to 260 nM. The minimum detectable antibody concentration was 0.68 nM. A competitive immunoassay was also developed for tetanus toxin C-fragment by allowing unlabeled and fluorescently labeled tetanus toxin C-fragment compete to bind to a limited fixed concentration of tetanus antibody. The immunoassay technique described in this work shows promise as a component of an integrated microfluidic device amenable to automation and relevant to development of clinical diagnostic devices.

Antibodies↗

On-chip free-flow magnetophoresis: continuous flow separation of magnetic particles and agglomerates.

The separation of magnetic microparticles was achieved by on-chip free-flow magnetophoresis. In continuous flow, magnetic particles were deflected from the direction of laminar flow by a perpendicular magnetic field depending on their magnetic susceptibility and size and on the flow rate. Magnetic particles could thus be separated from each other and from nonmagnetic materials. Magnetic and nonmagnetic particles were introduced into a microfluidic separation chamber, and their deflection was studied under the microscope. The magnetic particles were 2.0 and 4.5 microm in diameter with magnetic susceptibilities of 1.12 x 10(-4) and 1.6 x 10(-4) m(3) kg(-1), respectively. The 4.5-microm particles with the larger susceptibility were deflected further from the direction of laminar flow than the 2.0-microm magnetic particles. Nonmagnetic 6-microm polystyrene beads, however, were not deflected at all. Furthermore, agglomerates of magnetic particles were found to be deflected to a larger extent than single magnetic particles. The applied flow rate and the strength and gradient of the applied magnetic field were the key parameters in controlling the deflection. This separation method has a wide applicability since magnetic particles are commonly used in bioanalysis as a solid support material for antigens, antibodies, DNA, and even cells. Free-flow magnetophoretic separations could be hyphenated with other microfluidic devices for reaction and analysis steps to form a micro total analysis system.

Antibodies↗