Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

High perfomance liquid chromatography in pharmaceutical analyses.

In testing the pre-sale procedure the marketing of drugs and their control in the last ten years, high performance liquid chromatography replaced numerous spectroscopic methods and gas chromatography in the quantitative and qualitative analysis. In the first period of HPLC application it was thought that it would become a complementary method of gas chromatography, however, today it has nearly completely replaced gas chromatography in pharmaceutical analysis. The application of the liquid mobile phase with the possibility of transformation of mobilized polarity during chromatography and all other modifications of mobile phase depending upon the characteristics of substance which are being tested, is a great advantage in the process of separation in comparison to other methods. The greater choice of stationary phase is the next factor which enables realization of good separation. The separation line is connected to specific and sensitive detector systems, spectrafluorimeter, diode detector, electrochemical detector as other hyphernated systems HPLC-MS and HPLC-NMR, are the basic elements on which is based such wide and effective application of the HPLC method. The purpose high performance liquid chromatography (HPLC) analysis of any drugs is to confirm the identity of a drug and provide quantitative results and also to monitor the progress of the therapy of a disease.1) Measuring presented on the Fig. 1. is chromatogram obtained for the plasma of depressed patients 12 h before oral administration of dexamethasone. It may also be used to further our understanding of the normal and disease process in the human body trough biomedical and therapeutically research during investigation before of the drugs registration. The analyses of drugs and metabolites in biological fluids, particularly plasma, serum or urine is one of the most demanding but one of the most common uses of high performance of liquid chromatography. Blood, plasma or serum contains numerous endogenous compounds often present in concentrations much greater than those of analyte. Analiyte concentrations are often low, and in the case of drugs, the endogenous compounds are sometimes structurally very similar to the drug to be measured. The binding of drugs to the plasma protein also may occur which decreases the amount of free compound that is measured. To undertake the analyses of drugs and metabolites in body fluids the analyst is facet with several problems. The first problem is due to the complex nature of the body fluid, the drugs must be isolated by an extraction technique, which ideally should provide a relatively clean extract, and the separation system must be capable of resolving the drugs of interest from co extractives. All mentioned when we are using high performance liquid chromatography require good selections of detectors, good stationary phase, eluents and adequate program during separation. UV/VIS detector is the most versatile detector used in high performance liquid chromatography it is not always ideal since it is lack of specificity means high resolution of the analyte that may be required. UV detection is preferred since it offers excellent linearity and rapid quantitative analyses can be performed against a single standard of the drug being determined. Diode array and rapid scanning detector are useful for peak identification and monitoring peak purity but they are somewhat less sensitive then single wavelength detectors. In liquid chromatography some components may have a poor UV chromophores if UV detection is being used or be completely retained on the liquid chromatography column. Fluorescence and electrochemical detector are not only considerably more sensitive towed appropriate analytes but also more selective than UV detectors for many compounds. If at all possible fluorescence detectors are sensitive, stable, selective and easy to operate. It is selectivity shows itself in the lack of frontal components observed in plasma extract whereas electrochemical detection is nearly always associated with a major frontal peak than tails considerably. To date, the most sensitive method has been the reductive electrochemical detection and giving the excellent results in the investigation on some classes of drugs. Several high performance liquid chromatography oxidative electrochemical methods have been developed for the analyses of drugs and metabolites in body fluids. Mass spectrometer as specific detector with all variation of ionisation and interface (thermo spray, moving belt etc. ) or liquid chromatography-tandem mass spectrometry2,3,4,5). NMR as selective and specific detector in high performance liquid chromatography today is also in used. The development of a non-aqueous eluent for ion-exchange separation on silica has provided an excellent system which, when used in conjugation with an electrochemical detector, permits the analyses of an extensive range of especially basic drugs and metabolites. New packing materials such as polymeric, base deactivated silica's, pyrolysed carbon and the internal surface packing should offer the improved stability and higher efficiencies for certain classes of the compounds such as basic drugs. Microbore columns should become more accepted since they offer not only improved sensitivity but also a lower solvent consumption and consequently the reduced needs to dispose of noxious solvents. Many analyses of basic drugs are still performed by the same method of the ion-exchange chromatography on unmodified silica columns with an eluent buffered to about pH 9. Neutral or weakly acidic drugs for instance barbiturates can be chromatographed on a reversed phase system whilst acidic drugs for example paracetamol, cannabis are separated either by ion suppression or ion-pair chromatography on a reversed-phase packing material. In micelar liquid chromatography micelar mobile phases in reversed-phase instead of conventional hydro organic mobile phase is used. In micelar liquid chromatography complex electrostatic hydrophobic and steric interactions exist between the solute and both stationary and mobile phases. These enable the effective separation of samples of different nature. The main advantages of the use of a micelar solution in reversed-phase liquid chromatography are the solvent and the lower cost and toxicity, the biodegradability of the solvent and the easy dissolution of analytical samples, that enables the determination of drugs in physiological fluids without the need for previous separation of the proteins present in the samples. Using tetrabutylammonium phosphate as a competing base in the investigation of sulphonamides and heptanes sulfonate as ion pairing reagent. Ion pairing reagent is term used to describe enhanced retention as the result of the addition to the mobile phase of a large ion opposite charge to the molecular ions to be separated. For molecular cations alkyl sulphates or sulfonates are generally utilised.

Chromatography, High Pressure Liquid↗

Isolation and quantification of dinucleoside polyphosphates by using monolithic reversed phase chromatography columns.

In former studies, dinucleoside polyphosphates were quantified using ion-pair reversed-phase perfusion chromatography columns, which allows a detection limit in the micromolar range. The aim of this study was both to describe a chromatographic assay with an increased efficiency of the dinucleoside separation, which enables the reduction of analytical run times, and to establish a chromatographic assay using conditions, which allow MALDI-mass spectrometric analysis of the resulting fractions. We compared the performance of conventional silica reversed phase chromatography columns, a perfusion chromatography column and a monolithic reversed-phase C18 chromatography column. The effects of different ion-pair reagents, flow-rates and gradients on the separation of synthetic diadenosine polyphosphates as well as of diadenosine polyphosphates isolated from human platelets were analysed. Sensitivity and resolution of the monolithic reversed-phase chromatography column were both higher than that of the perfusion chromatography and the conventional reversed phase chromatography columns. Using a monolithic reversed-phase C18 chromatography column, diadenosine polyphosphates were separable baseline not only in the presence of tetrabutylammonium hydrogensulfate (TBA) but also in the presence of triethylammonium acetate (TEAA) as ion-pair reagent. The later reagent is useful because, in contrast to TBA, it is compatible with MALDI mass-spectrometric methods. This makes TEAA particularly suitable for identification of unknown nucleoside polyphosphates. Furthermore, because of the lower backpressure of monolithic reversed-phase chromatography columns, we were able to significantly increase the flow rate, decreasing the amount of time for the analysis close to 50%, especially using TBA as ion-pair reagent. In summary, monolithic reversed phase C18 columns markedly increase the sensitivity and resolution of dinucleoside polyphosphate analysis in a time-efficient manner compared to reversed-phase perfusion chromatography columns or conventional reversed-phase columns. Therefore, further dinucleoside polyphosphate analytic assays should be based on monolithic silica C18 columns instead of perfusion chromatography or conventional silica reversed phase chromatography columns. In conclusion, the use of monolithic silica C18 columns will lead to isolation and quantification of up to now unknown dinucleoside polyphosphates. These chromatography columns may facilitate further research on the biological roles of dinucleoside polyphosphates.

Blood Platelets↗

Immune chromatography: a quantitative radioimmunological assay.

Immune chromatography, a radioimmunological binding assay, employs paper chromatography to separate immune complexes from free antigen and antibodies. During chromatography free antigen and antibodies become distributed throughout the paper, while immune complexes remain near the bottoms of the strips. The chromatographic differences can be made quantitative by using either iodinated antigens or antibodies. Under these conditions nanogram quantities of antigen can be detected or antibodies in sera diluted several 1000-fold. The immune chromatography assay can also be performed as an indirect assay, since the paper strips are cut from nitrocellulose paper. In this case the immune components are absorbed by the paper during chromatography. Antigen is then detected with an iodinated second antibody. The indirect immune chromatography assay is particularly useful for identifying different sera that react with the same antigen. Reaction with the first serum before chromatography reduces the amount of antigen available to the second serum following chromatography. In addition to characterizing the immune chromatography procedure, we discuss the possible applications of chromatography assays for the quantitation of other types of molecular binding interactions.

Animals↗

Rapid miniaturized chromatography for technetium-99m-tetrofosmin.

UNLABELLED: The purpose of this investigation was to develop and evaluate a new and rapid miniaturized chromatography system that would accurately assess the radiochemical purity of 99mTc-tetrofosmin without the problems of solvent ratios and time requirements associated with the manufacturer's recommended procedure. METHODS: The migration of the radiochemical components of 99mTc-tetrofosmin was evaluated using various chromatography media with ethyl acetate as the solvent. After optimization of the miniaturized system, radiochemical purity assessments were performed simultaneously on 23 99mTc-tetrofosmin preparations using both recommended and miniaturized chromatography systems. RESULTS: A miniaturized chromatography system consisting of Whatman 1 chromatography paper with ethyl acetate was developed for the radiochemical purity assessment of 99mTc-tetrofosmin. Radiochemical purity results for 99mTc-tetrofosmin preparations were similar with both recommended and miniaturized chromatography methods, with a mean difference of 1.5% +/- 1.2% (s.d.). Differences in radiochemical purity results between the two chromatography systems were less than 2% (20 of 23 evaluations) with most preparations. CONCLUSION: Radiochemical purity results for 99mTc-tetrofosmin preparations were similar with both the manufacturer's recommended chromatography and miniaturized chromatography systems. The miniaturized chromatography system is easier to use, and the time required to perform radiochemical purity assessments is substantially reduced.

Acetates↗

Early milestones in the development of ion-exchange chromatography: a personal account.

Ion chromatography as we know it today was built on a foundation of knowledge accumulated over a period of many years. Here, we review some of the outstanding earlier achievements in ion-exchange chromatography. Beginning about 1947. Spedding and Powell at Iowa State published a series of papers describing practical methods for preparative separation of the rare earths by displacement ion-exchange chromatography. The same group then demonstrated the ion-exchange separation of 14N and 15N isotopes in ammonia. Beginning in the 1950s. Kraus and Nelson at Oak Ridge published numerous analytical methods for metal ions based on separation of their chloride, fluoride, nitrate or sulfate complexes by anion chromatography. In the period from about 1960 to 1980 many clever chromatographic methods for metal ion separations were reported by researchers throughout the world and automatic in-line detection was gradually introduced. A truly innovative method by Small, Stevens and Bauman at Dow Chemical Co. marked the birth of modern ion chromatography. Anions, as well as cations, could now be separated quickly and conveniently by a system of suppressed conductivity detection. A method for anion chromatography with non-suppressed conductivity detection was published by Gjerde et al. in 1979. This was followed by a similar method for cation chromatography in 1980. Ion chromatography as we know it today did not just happen. It was built on a solid foundation of knowledge that has accumulated over a period of many years. Revisiting the older ion-exchange chromatography serves not only to pay tribute to some remarkable accomplishments, but it can also be a learning experience. Trends and ideas in science tend to run in repeating cycles. Thus, an awareness of older work may provide inspiration for new research using improved contemporary technology. Selection of milestones is a rather personal matter. I chose to write about subjects of which I came to have a firsthand knowledge during my career. The topics selected are in roughly chronological order and cover the period from about 1945 to 1980. An effort has been made to explain the chemical principles as well as to recount the major accomplishments of the various research projects.

Chromatography, Ion Exchange↗

Wrong gas/liquid partition data by gas chromatography.

In a paper published in 1992 [K.S. Reddy, J.-Cl. Dutoit, E.sz. Kováts, Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr. 609 (1992) 229] retention indices and standard chemical potential differences (SPOT-s) are given for about 160 solutes on a liquid branched paraffin hydrocarbon of the carbon number, z = 78. For the temperature dependence of the SPOT-s the proposal of Kirchhoff was accepted i.e. that at higher temperatures the molar heat capacity difference of the solute between the gas phase and the solution is nearly constant in a broad temperature range. The data were determined under conditions where the effect of adsorption could be neglected. By comparing the published data with those determined on another branched paraffin of the carbon number, z = 87 [F. Riedo, D. Fritz, G. Tarján, E.sz. Kováts, A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr. 126 (1976) 63] it is shown that the reported thermodynamic constants of solutes determined experimentally at higher temperatures (the group "H") are wrong on C78. In the present paper, the method of correction and the resulting corrected data are given. In later papers retention data are given on eight polar derivatives of the hydrocarbon C78 relative to those measured on the nonpolar standard [R. Cloux, G. Défayes, K. Fóti, J.-Cl. Dutoit, E.sz. Kováts, Pair-wise interactions by gas chromatography. III. Synthesis of isosteric stationary phases for gas chromatography, Synthesis (1993) 909; G. Défayes, K.S. Reddy, A. Dallos, E.sz. Kováts, Pair-wise interactions by gas chromatography. V. Interaction free enthalpies of solutes with primary chloro- and bromo-alkanes, J. Chromatogr. A 699 (1995) 131; K.S. Reddy, E.sz. Kováts, Pair-wise interactions by gas chromatography. II. Sociation free enthalpies of some hydrogen bonding solutes with non-associated primary alcohol groups, Chromatographia 34 (1992) 249; K.S. Reddy, R. Cloux, E.sz. Kováts, Pair-wise interactions by gas chromatography. IV. Interaction free enthalpies of solutes with trifluoromethyl-substituted alkanes, J. Chromatogr. A 673 (1994) 181; K.S. Reddy, R. Cloux, E.sz. Kováts, Pair-wise interactions by gas chromatography. VI. Interaction free enthalpies of solutes with primary methoxyalkane, cyanoalkane and alkanethiol groups, J. Chromatogr. A 704 (1995) 387; A. Dallos, A. Sisak, Z. Kulcsár, E.sz. Kováts, Pair-wise interactions by gas chromatography. VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A 904 (2000) 211]. Obviously, the same data which are wrong in the nonpolar standard are also wrong in these solvents. The corrected data in the polar solvents are given in supplementary tables.

Chromatography, Gas↗

Hydrophilic-interaction chromatography for the separation of peptides, nucleic acids and other polar compounds.

When a hydrophilic chromatography column is eluted with a hydrophobic (mostly organic) mobile phase, retention increases with hydrophilicity of solutes. The term hydrophilic-interaction chromatography is proposed for this variant of normal-phase chromatography. This mode of chromatography is of general utility. Mixtures of proteins, peptides, amino acids, oligonucleotides, and carbohydrates are all resolved, with selectivity complementary to those of other modes. Typically, the order of elution is the opposite of that obtained with reversed-phase chromatography. A hydrophilic, neutral packing was developed for use in high-performance hydrophilic-interaction chromatography. Hydrophilic-interaction chromatography is particularly promising for such troublesome solutes as histones, membrane proteins, and phosphorylated amino acids and peptides. Hydrophilic-interaction chromatography fractionations resemble those obtained through partitioning mechanisms. The chromatography of DNA, in particular, resembles the partitioning observed with aqueous two-phase systems based on polyethylene glycol and dextran solutions.

Acids↗

Isolation of a recombinant antibody from cell culture supernatant: continuous annular versus batch and expanded-bed chromatography.

Annular chromatography represents a crossflow approach to chromatographic separations, that allows the continuous separation of multicomponent mixtures. The potential of the method for continuous bioseparation has been discussed for some time, however, we demonstrate for the first time the processing of a complex feed (cell culture supernatant) taken from an actual (bio)process. Moreover, while previously published applications of annular chromatography concentrated on noninteractive (gel filtration) or nonspecific (ion exchange) chromatography, we show the possibility of continuous annular affinity chromatography. In particular, a commercially available preparative continuous annular chromatography (P-CAC) system was used to purify a recombinant antibody (human IgG(1)-kappa) from CHO cell culture supernatants by (pseudo)affinity chromatography on hydroxyapatite (HA) and rProtein A. Methods developed using small (2 mL) batch columns could be directly transferred to the P-CAC, where they yielded similar results in terms of final product quality. Yields were between 87% and 92% in the case of HA and between 77% and 82% in the case of rProtein A chromatography. DNA removal was nearly quantitative in all cases. Concomitantly, the antibody fraction of the total protein content was raised by one order of magnitude in HA and by a factor of 50 by rProtein A chromatography. In addition, a novel HA material (particle diameter -120 microm) was investigated, which was compatible with expanded-bed applications. However, the final purity of the antibody thus obtained and also the yields (<70%) were less than satisfactory.

Animals↗

Continuous purification of a clotting factor IX concentrate and continuous regeneration by preparative annular chromatography.

Preparative continuous annular chromatography, a method to separate proteins in a truly continuous manner, was investigated in an industrial environment. Plasma-derived clotting factor IX concentrate was used as model protein. Separation of vitronectin, a common impurity in commercial available factor IX concentrates, from factor IX was studied and compared to conventional packed bed chromatography in batch mode. As sorbent, Toyopearl DEAE 650M was used. Regeneration was performed simultaneously with the purification of factor IX in continuous mode. All required parameters applied for preparative annular chromatography such as feed flow-rate and elution flow-rate were first estimated from experiments on conventional batch columns. Then preparative annular chromatography and conventional packed beds were compared regarding enrichment, purity and productivity. Three different process scenarios, the optimal batch process,the preparative annular chromatography process and the batch process equivalent to the preparative annular chromatography process were investigated. The productivity of the optimal batch process was higher than that of the preparative annular chromatography and batch process equivalent to the preparative annular chromatography process. Therefore the throughput could not be increased by the use of the continuous chromatographic system.

Blotting, Western↗

Affinity chromatography to remove viruses during preparation of plasma derivatives.

The use of affinity chromatography methods to purify proteins from complex solutions is well established. The specific use of immuno-affinity chromatography, wherein antibody directed toward a target protein is utilized, has proven to be a particularly effective purification method. Application of immuno-affinity chromatography methods for the isolation of plasma derivatives has now been established and the purity of such products has been truly remarkable. Studies conducted by Baxter have compared the effect of immuno-affinity chromatography on the separation of plasma protein contaminants and model viruses from Factor VIII:C. The results of these studies have indicated that plasma protein contaminant (eg. fibrinogen) reduction during the process of Factor VIII:C immuno-affinity chromatography occurs more gradually than does virus reduction. By using residual plasma protein contamination in Factor VIII:C preparations, the general effectiveness of the immuno-affinity chromatography step in removing virus can be routinely evaluated. Determinations made by Baxter have indicated that greater than 4 logs of reduction in protein contamination is routinely achieved during Factor VIII:C immuno-affinity chromatography at manufacturing scale. Bench scale studies have confirmed this result as well as showing the reduction of model viruses. While the viral safety of plasma derivatives is dependent on the overall manufacturing process, it is clear that immuno-affinity chromatography offers a powerful means of reducing product contamination and enhancing safety.

Biological Products↗

Location by paper chromatography of compensatory ovarian hypertrophy (COH) inhibiting activity in acetic acid extracts from bovine pineals.

Acetic acid extracts of bovine pineals and cerebral cortex were separated on Sephadex G-25 columns. Subsequently two low molecular weight fractions, F2 and F3, were ultrafiltered through the membranes UM2 and UM05. The UM05 residues were gel filtered on Sephadex G-15 columns or chromatographed on Dowex W50-X4 columns. Fractions from these columns were tested and those which showed COH-inhibiting activity were separated by preparative paper chromatography in different solvents. The absorption spectra of those fractions were recorded and tested for COH-inhibiting activity were separated by preparative paper chromatography in different solvents. The absorption spectra of those fractions were recorded and tested for COH-inhibition. By these methods, a COH-inhibitor was localized in three different solvents. Some active paper chromatography fractions were studied in high pressure, reverse phase, liquid chromatography. This latter method showed that the active fractions obtained by paper chromatography contain several orthophthlaldehyde (OPT) positive compounds. Key words: acetic acid, bovine pineal extracts, compensatory ovarian hypertrophy (COH), paper chromatography, high pressure, reverse phase, liquid chromatography.

Acetates↗

Chromatography as a reference technique for the determination of clinically important steroids.

Chromatographic methods (paper chromatography, thin layer chromatography, high performance liquid chromatography, gas chromatography and gas chromatography-mass spectrometry) for the determination of clinically important steroids in biological specimens are reviewed. The emphasis is on the use of gas chromatography, gas chromatography-mass spectrometry and high performance liquid chromatography as reference rather than routine techniques. Chromatographic methods are compared with colorimetric, fluorimetric and radioimmunoassay procedures in terms of simplicity of operation, cost and ability to analyse large numbers of specimens. The importance of correct specimen collection and storage are discussed. Sample preparation techniques for the various analytical methods are described. These include extraction of free and conjugated steroids from serum, plasma, urine and saliva by solvent partition, with polymer-based resins such as Amberlite XAD-2, DEAE-Sephadex and Sephadex resins bonded with various other function groups and, more recently, with chemically bonded reversed-phase silicas.

Chromatography↗

The contributions of Csaba Horváth to liquid chromatography.

This article is not a biographic description of the life of Csaba Horváth, but an attempt to describe his most important contributions to liquid chromatography, as viewed by an author who himself started with HPLC in 1973. With the introduction of columns packed with rigid pellicular particles, which could withstand high pressures, the combination of fast separations with high efficiency was designated high pressure liquid chromatography about 35 years ago. The contribution of Horváth to the birth of modern LC was to imagine the potential for high-speed separations in LC by transferring ideas and technology from gas chromatography. From this time, his strong participation in understanding and describing the processes of separation science made him a leading scientist in fundamental studies of separation principles until his passing away in April 2004. In addition to being one of the forefathers of modern liquid chromatography, Csaba Horváth described both the ionic interactions and the hydrophobic interactions on ion exchangers as well as on reversed phase materials and developed a theoretical basis for understanding these processes. If one person should be mentioned as the inventor of ion-pair chromatography of organic compounds, of hydrophobic interaction chromatography, and of the theoretical basis for reversed phase chromatography, this person is Csaba Horváth. Throughout the last 30 years he also had a strong interest in studying proteins in separation processes, and in the last decade he made valuable contributions to capillary electrochromatography, particularly for separation of proteins on monolithic columns. For this author is difficult to find another person who has had a greater impact on liquid chromatography than Csaba Horváth.

Chromatography, Liquid↗

Continuous annular chromatography.

In recent years the demand for process scale chromatography systems in the industrial downstream process has been increasing steadily. Chromatography seems to be the method of choice when biological active compounds must be recovered from a mixture containing dozens of side products and contaminants as it is for example the case when processing fermentation broths. Since chromatography can solve almost any separation problem under mild operating conditions, a continuous chromatography system represents an extremely attractive and powerful option for such large-scale applications. The increasing number of biotechnological products forces system suppliers of the downstream processing side to develop new and improved high throughput purification technologies. Continuous Annular Chromatography (CAC) has been shown to be the only continuous chromatography technique to fulfill the high demands raised by modern biotechnological productions. In recent years Prior Separation Technology has transferred the principle of Continuous annular chromatography from the research laboratories to the fully developed industrial downstream process scale. The technology is now called Preparative Continuous Annular Chromatography--P-CAC. It can be placed at any stage in the downstream line starting at the very early stages where capturing and concentration of the desired product is required down to the polishing steps, which assure a sufficient final purity of the end product.

Biotechnology↗

Applications of affinity chromatography in proteomics.

Affinity chromatography is a powerful protein separation method that is based on the specific interaction between immobilized ligands and target proteins. Peptides can also be separated effectively by affinity chromatography through the use of peptide-specific ligands. Both two-dimensional electrophoresis (2-DE)- and non-2-DE-based proteomic approaches benefit from the application of affinity chromatography. Before protein separation by 2-DE, affinity separation is used primarily for preconcentration and pretreatment of samples. Those applications entail the removal of one protein or a class of proteins that might interfere with 2-DE resolution, the concentration of low-abundance proteins to enable them to be visualized in the gel, and the classification of total protein into two or more groups for further separation by gel electrophoresis. Non-2-DE-based approaches have extensively employed affinity chromatography to reduce the complexity of protein and peptide mixtures. Prior to mass spectrometry (MS), preconcentration and capture of specific proteins or peptides to enhance sensitivity can be accomplished by using affinity adsorption. Affinity purification of protein complexes followed by identification of proteins by MS serves as a powerful tool for generating a map of protein-protein interactions and cellular locations of complexes. Affinity chromatography of peptide mixtures, coupled with mass spectrometry, provides a tool for the study of protein posttranslational modification (PTM) sites and quantitative proteomics. Quantitation of proteomes is possible via the use of isotope-coded affinity tags and isolation of proteolytic peptides by affinity chromatography. An emerging area of proteomics technology development is miniaturization. Affinity chromatography is becoming more widely used for exploring PTM and protein-protein interactions, especially with a view toward developing new general tag systems and strategies of chemical derivatization on peptides for affinity selection. More applications of affinity-based purification can be expected, including increasing the resolution in 2-DE, improving the sensitivity of MS quantification, and incorporating purification as part of multidimensional liquid chromatography experiments.

Chromatography, Affinity↗

Purification of heparinase and heparitinase by affinity chromatography on glycosaminoglycan-bound AH-Sepharose 4B.

Heparinase and heparitinase were separated from an extract of Flavobacterium heparinum, induced with heparin by using column chromatography on hydroxylapatite. As the heparinase preparation contained chondroitinases B and C, chondroitinase B was removed by rechromatography on a hydroxylapatite column. Chondroitinase C was then eliminated by column chromatography on O-phosphono("phospho")-cellulose. The heparinase preparation thus obtained was free from sulfoamidase for 2-deoxy-2-sulfoamino-D-glucose (GlcN-2S), sulfatase for 2-amino-2-deoxy-6-O-sulfo-D-glucose (GlcN-6S), as well as delta 4,5glycosiduronase for the unsaturated disaccharides obtained from heparin. The remaining sulfatase for 4-deoxy-alpha-L-threo-hex-4-enopyranosyluronic acid 2-sulfate (delta UA-2S) in the heparinase preparation was removed by affinity chromatography with dermatan sulfate-bound AH-Sepharose 4B coated with dermatan sulfate. The heparitinase preparation separated by column chromatography on hydroxylapatite was purified by affinity chromatography with heparin-bound AH-Sepharose 4B coated with heparin. Sulfatase for 2-amino-2-deoxy-6-O-sulfo-D-glucose (GlcN-6S) and delta 4,5glycosiduronase for the unsaturated disaccharides obtained from heparin were removed by this chromatography. Sulfatase for 4-deoxy-alpha-L-threo-hex-4-enopyranosyluronic acid 2-sulfate (delta UA-2S) remaining in the heparitinase preparation was finally removed by column chromatography on hydroxylapatite. The recoveries of the purified preparations of heparinase and heparitinase were estimated to be 39 and 50%, respectively, from the crude enzyme fractions obtained by the first column chromatography on hydroxylapatite. The purified heparinase and heparitinase were free from all enzymes that could degrade the sulfated unsaturated disaccharides produced from heparin with heparinase.

Chromatography, Affinity↗

Purification by affinity chromatography of 2,4-dienoyl-CoA reductases from bovine liver and Escherichia coli.

1. Dye-ligand chromatography using immobilized Cibacron blue F3GA (blue Sepharose CL-6B) and Procion red HE3B (Matrex gel red A) as matrices and general ligand chromatography employing immobilized 2',5'-ADP (2',5'-ADP-Sepharose 4B) and immobilized 3',5'-ADP (3',5'-ADP-Agarose) were employed for purification of NADPH-dependent 2-enoyl-CoA reductase and 2,4-dienoyl-CoA reductase from bovine liver (formerly called 4-enoyl-CoA reductase [Kunau, W. H. and Dommes, P. (1978) Eur. J. Biochem. 91, 533-544], as well as 2,4-dienoyl-CoA reductase from Escherichia coli. 2. The NADPH-dependent 2-enoyl-CoA reductase from bovine liver mitochondria was separated from 2,4-dienoyl-CoA reductase by dye-ligand chromatography (Matrex gel red A/KCl gradient) as well as by general ligand affinity chromatography (2',5'-ADP-Sepharose 4B/NADP gradient). The enzyme was obtained in a highly purified form. 3. The NADPH-dependent 2,4-dienoyl-CoA reductase from bovine liver mitochondria was purified to homogeneity using blue Sepharose CL-6B, Matrex gel red A, and 2',5'-ADP-Sepharose 4B chromatography. 4. The bacterial 2,4-dienoyl-CoA reductase was completely purified by ion-exchange chromatography on DEAE-cellulose followed by a single affinity chromatography step employing 2',5'-ADP-Sepharose 4B and biospecific elution from the column with a substrate, trans,trans-2,4-decadienoyl-CoA. 5. The application of dye-ligand and general ligand affinity chromatography for purification of NADPH-dependent 2,4-dienoyl-CoA reductases taking part in the beta-oxidation of unsaturated fatty acids is discussed. It is concluded that making use of coenzyme specificity for binding and substrate specificity for elution is essential for obtaining homogeneous enzyme preparations.

Animals↗

Drug screening by enzyme immunoassay (EMIT) and thin-layer chromatography (Drug Skreen).

Urine samples (n = 300) were examined for drugs by thin-layer chromatography ("Drug Skreen", Brinkmann Corp.) and by the "Enzyme Multiplied Immunoassay Technique" ("Emit", Syav Corp.). The results of both methods were compared for the detection of opiates, barbiturates and amphetamines. In more than 90% of the determinations identical results were obtained with both methods. About 10% of the results of the Emit barbiturate assay differed from those of thin-layer chromatography and therefore had to be further investigated by gas liquid chromatography. It could be demonstrated that the barbiturate determination by the Emit system correlated better with the results of gas liquid chromatography. From the results of this study it is suggested that thin-layer chromatography is used as a screening test, and to confirm positive results with other methods such as Emit. If the abuse of barbiturates or opiates is suspected the corresponding Emit test should also be performed, even in cases of a negative thin-layer chromatography screening. Confirmation with a third method such as gas liquid chromatography is necessary, if thin-layer chromatography and Emit lead to divergent results.

Amphetamines↗