Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

A calibration method that simplifies and improves accurate determination of peptide molecular masses by MALDI-TOF MS.

The use of delayed ion extraction in MALDI time-of-flight mass spectrometry distorts the linear relationship between m/z and the square of the ion flight time (t2) with the consequence that, if a mass accuracy of 10 ppm or better is to be obtained, the calibrant signals have to fall close to the analyte signals. If this is not possible, systematic errors arise. To eliminate these, a higher-order calibration function and thus several calibrant signals are required. For internal calibration, however, this approach is limited by signal suppression effects and the increasing chance of the calibrant signals overlapping with analyte signals. If instead the calibrants are prepared separately, this problem is replaced by an other; i.e., the ion flight times are dependent on the sample plate position. For this reason, even if the calibrants are placed close to the sample, the mass accuracy is not improved when a higher-order calibration function is applied. We have studied this phenomenon and found that the relative errors, which result when moving from one sample to the next, are directly proportional to m/z. Based on this observation, we developed a two-step calibration method, that overcomes said limitations. The first step is an external calibration with a high-order polynomial function used for the determination of the relation between m/z and t2, and the second step is a first-order internal correction for sample position-dependent errors. Applying this method, for instance, to a mass spectrum of a mixture of 18 peptides from a tryptic digest of a recombinant protein resulted in an average mass error of 1.0 ppm with a standard deviation of 3.5 ppm. When instead using a conventional two-point internal calibration, the average relative error was 2.2 ppm with a standard deviation of 15 ppm. The new method is described and its performance is demonstrated with examples relevant to proteome research.

Adrenocorticotropic Hormone↗

Solid-phase extraction combined with high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis of pesticides in water: method performance and application in a reconnaissance survey of residues in drinking water in Greater Cairo, Egypt.

Monitoring of water resources for pesticide residues is often needed to ensure that pesticide use does not adversely impact the quality of public water supplies or the environment. In many rural areas and throughout much of the developing world, monitoring is often constrained by lack of testing facilities; thus, collection of samples and shipment to centralized laboratories for analysis is required. The portability, ease of use, and potential to enhance analyte stability make solid-phase extraction (SPE) an attractive technique for handling water samples prior to their shipment. We describe performance of an SPE method targeting a structurally diverse mixture of 25 current-use pesticides and two common degradates in samples of raw and filtered drinking water collected in Greater Cairo, Egypt. SPE was completed in a field laboratory in Egypt, and cartridges were shipped to the United States for elution and high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis. Quantitative and reproducible recovery of 23 of 27 compounds (average = 96%; percent relative standard deviation = 21%) from matrix spikes (1 microg L-1 per component) prepared in the field and from deionized water fortified similarly in the analytical laboratory was obtained. Concurrent analysis of unspiked samples identified four parent compounds and one degradate in drinking water samples. No significant differences were observed between raw and filtered samples. Residue levels in all cases were below drinking water and "harm to aquatic-life" thresholds, indicating that human and ecological risks of pesticide contamination were relatively small; however, the study was limited in scale and scope. Further monitoring is needed to define spatial and temporal variation in residue concentrations. The study has demonstrated the feasibility of performing studies of this type using SPE to extract and preserve samples in the field. The approach should be broadly applicable in many settings.

Chromatography, High Pressure Liquid↗

Laser desorption/ionization time-of-flight mass spectrometry on sol-gel-derived 2,5-dihydroxybenzoic acid film.

This work presents a novel method for direct desorption/ ionization of analytes from sol-gel-derived film. 2,5-Dihydroxy benzoic acid (DHB), a common MALDI matrix, was incorporated into a sol-gel polymeric structure. The sol-gel-derived DHB thin film can assist the mass analysis of analytes by laser desorption/ionization, with a matrix interference-free background in the mass spectra. The sol-gel-derived film can function as an energy absorber during laser irradiation because it contains DHB molecules. Furthermore, laser irradiation with normal laser power (70-110 microJ) is not likely to generate any background ions from this sol-gel-DHB derived film. The samples were prepared straightforwardly. After a thin film was formed on a Parafilm membrane from the sol-gel-derived DHB solution coating, the sample solution was directly added to the top of the film, for laser desorption/ ionization mass analysis. The analyte signals were homogeneously obtained on the sol-gel-derived DHB film. Experimental results show that the optimum concentrations of DHB incorporated in the sol-gel solution were between 7,500 ppm and 10,000 ppm, providing a matrix interference-free background. Analytes, including small proteins, peptides, amino acids, and small organics, were used to demonstrate the effectiveness of the proposed method. However, a higher laser power (> 110 microJ) than normal was required to desorb small proteins from the sol-gel-derived DHB film. Therefore, a few matrix ions desorbed from the thin film were generated during laser irradiation. The detection limit for both small molecules and proteins, using this sol-gel-assisted laser desorption/ ionization (SGALDI) mass spectrometry (MS), was as low as 81 fmol. However, a mass spectrometer with cutoff-mass selection could detect 8.1 fmol of cytochrome c. The largest analyte observed by the SGALDI-MS in this study was myoglobin.

Amino Acids↗

Separation and determination of active components in Schisandra chinensis Baill. and its medicinal preparations by non-aqueous capillary electrophoresis.

A simple, economical and effective non-aqueous capillary electrophoresis separation and detection method was developed for the quantification of deoxyschizandrin and gamma-schizandrin in Schisandra chinensis Baill. and its medicinal preparations for the first time. After optimization of separation conditions, a buffer of 140 mmol/L sodium cholate in methanol was selected for separating the two analytes, but baseline separation of SA and SB in real samples was not obtained. Therefore second-order derivative electropherograms were applied for resolving overlapping peaks. Regression equations revealed good linear relationships (correlation coefficients 0.9975--0.9988) between peak heights in second-order derivative electropherograms and concentrations of the two analytes. The relative standard deviations (RSD) of the migration times and the peak height of the two constituents were in the ranges 0.62--0.79% and 0.25--2.17% (intra-day) and 1.43--2.06 and 4.08--5.72% (inter-day), respectively. The recoveries of the two constituents ranged from 93.2 to 103.0%. The results indicated that baseline separation of the analytes was sometimes hard to obtain in real samples and second-order derivative electropherograms were applicable for the resolution and analysis of overlapping peaks.

Cyclooctanes↗

Analysis of ethoxylated nonionic surfactants and their metabolites by liquid chromatography/atmospheric pressure ionization mass spectrometry.

The widespread use and questionable environmental acceptability of nonionic surfactants make the alkylphenol ethoxylates (APEOs) and their neutral and acidic degradation products a focus of interest in environmental analytical chemistry. The characterization and especially quantification of polyethoxylate mixtures in environmental matrices is a challenge, because of the complexity of the mixtures. A review on trace analysis of APEOs using atmospheric pressure ionization mass spectrometry, including sample preparation and liquid chromatographic separation, is presented. In this Special Feature, the performances of two ionization methods, atmospheric pressure chemical ionization and electrospray ionization, is discussed in terms of selectivity and sensitivity toward oligomeric mixtures of APEOs. Capabilities and limitations associated with the liquid chromatographic/mass spectrometric detection of APEOs, their main degradation products and their halogenated metabolites, and also specific issues related to the sample preparation, formation of fragments, adducts and cluster ions, quantification of oligomeric mixtures and signal suppression effects in complex matrices, are discussed. Conclusions and future perspectives are outlined.

Chromatography, High Pressure Liquid↗

Determination of ascorbic acid and dehydroascorbic acid in biological samples by high-performance liquid chromatography using subtraction methods: reliable reduction with tris[2-carboxyethyl]phosphine hydrochloride.

Determination of dehydroascorbic acid in biological samples most commonly involves indirect measurement. The concentration is calculated by subtraction of the measured ascorbic acid concentration from that of total ascorbic acid analyzed after reduction of the dehydroascorbic acid present; a methodology also referred to as subtraction methods. Consequently, successful determination of dehydroascorbic acid is dependent on proper sample handling, quantitative reduction of the compound, and accurate quantification of both ascorbic acid and total ascorbic acid. In this paper, the recently introduced reductant tris[2-carboxyethyl]phosphine (TCEP) is evaluated as a reliable alternative to the commonly used reducing agent dithiothreitol (DTT). The results show that TCEP offers a more efficient reduction of dehydroascorbic acid at low pH compared to that of DTT. Moreover, while DTT maintains a reducing sample environment for less than 24 h, TCEP show complete protection from oxidation of ascorbic acid for at least 96 h following sample preparation. Removal of TCEP prior to analysis is unnecessary. A revised HPLC-EC method incorporating TCEP as reductant as well as the coanalysis of isoascorbic acid and uric acid is presented. The within- and between-day coefficients of variation for the complete assay are less than 1.5 and 3.5% for all analytes. As a whole, the method presented here is simpler and more reliable than existing methods.

Ascorbic Acid↗

Identification and quantification of ethylene glycol and diethylene glycol in plasma using gas chromatography-mass spectrometry.

A method for the gas chromatographic-mass spectrometric identification and quantification of ethylene glycol and diethylene glycol in plasma is described. Such a method is necessary in clinical and forensic toxicology to diagnose probable intoxication and to control the efficacy of detoxification. For sample preparation, the glycols were isolated using acetone after the addition of 1,3-propylene glycol as internal standard. The glycols were then esterified by pivalic acid (pivalic acid anhydride, triethylamine and methanol, 70 degrees C, 15 min) to improve their gas chromatographic characteristics. The glycols were first identified by a comparison of the full mass spectra with reference spectra and then quantified. Therefore, the peak area ratio in the total ion chromatogram (ethylene glycol or diethylene glycol/1,3-propanediol) of the sample was compared with the calibration curve in which the peak area ratios of the standards (0.05, 0.1, 0.5, 1 and 2 g/l), prepared in the same way, were plotted versus their concentrations. The method was linear at least from 0.05 to 2 g/l, with a detection limit of less than 0.01 g/l. The analytical recoveries were 99.2-102.9% for the different concentrations. Precision studies show coefficients of variation of 3.0-6.3% for the different concentrations.

Ethylene Glycols↗

A review of modern sample-preparation techniques for the extraction and analysis of medicinal plants.

Sample preparation is the crucial first step in the analysis of herbs. In recent years there has been increasing interest worldwide in the use of alternative/herbal medicine for the prevention and treatment of various illnesses. Currently, however, quality-related problems (lack of consistency, safety, and efficacy) seem to be overshadowing the potential genuine health benefits of various herbal products. Thus, the development of "modern" sample-preparation techniques with significant advantages over conventional methods for the extraction and analysis of medicinal plants is likely to play an important role in the overall effort of ensuring and providing high-quality herbal products to consumers worldwide. In this article, recent developments and applications of modern sample-preparation techniques for the extraction, clean-up, and concentration of analytes from medicinal plants or herbal materials are reviewed. These modern techniques include solid-phase microextraction, supercritical-fluid extraction, pressurized-liquid extraction, microwave-assisted extraction, solid-phase extraction, and surfactant-mediated extraction.

Plant Extracts↗

Liquid chromatography-mass spectrometry method for determination of tetramethylpyrazine and its metabolite in dog plasma.

A liquid chromatography-mass spectrometry method is described for the determination of tetramethylpyrazine (TMP) and its active metabolite, 2-hydroxymethyl-3,5,6-trimethylpyrazine (HTMP) in dog plasma. This method involves a plasma clean-up step using protein precipitation procedure followed by LC separation and positive electrospray ionization mass spectrometry detection (ESI-MS). Chromatographic separation of the analytes was achieved on a C18 column using a mobile phase of methanol, water and acetic acid (50:50:0.6, v/v/v) at a flow rate of 1.0 ml/min. Selected ion monitoring (SIM) mode was used for analyte quantitation at m/z 137.2 for TMP, m/z 153.2 for HTMP and m/z 195.2 for caffeine. The linearity was obtained over the concentration ranges of 20-6000 ng/ml for TMP and 20-4000 ng/ml for HTMP and the lower limit of quantitation was 20 ng/ml for both analytes. For each level of QC samples, both inter- and intra-day precisions (R.S.D.) were <or=7.4% for TMP and <or=6.0% for HTMP, and accuracy (R.E.) was +/-6.0% for TMP and <or=3.5% for HTMP. The proposed LC-MS method was successfully applied to the pharmacokinetic studies of a TMP formulation preparation after oral administration to beagle dogs.

Animals↗

Distribution of the UV filter 3-benzylidene camphor in rat following topical application.

A straightforward analytical method for determination of 3-benzylidene camphor (3-BC) in rat adipose tissue, brain, liver, muscle, plasma and testis following topical application was developed and validated. Three exposure levels (60, 180 and 540 mg kg(-1) day(-1)) were tested for 65 days in male Sprague-Dawley rats (24 days postnatal). Sample preparation involving homogenization and n-heptane or methanol extraction of the tissue was applied before injection into the LC-ESI-MS-MS system. The response was linear from 2 to 100 microg l(-1) for the qualifier and the quantifier MRM transitions (R(2) (quantifier) > 0.994). Detection limit of the method corresponded to 0.005 microg g(-1) tissue and 12.5 microg l(-1) plasma, respectively. Recovery was determined for all tissues (adipose tissue: 40%; all other tissues: 80-100%) at three individual levels. 3-(4-Methyl benzylidene camphor) (4-MBC) was used throughout the study as internal standard. 3-Benzylidene camphor was detected in all tissues at all exposure levels at concentrations between 0.05 microg g(-1) (liver) and 36 microg g(-1) (adipose tissue) and in plasma at 16-89 microg l(-1). The method allowed for the quantification of 3-benzylidene camphor in all tested tissues following topical application. Furthermore, it was shown that 3-benzylidene camphor can be found in various tissues in the rat following topical application. These findings may suggest that following use of 3-benzylidene camphor containing sunscreen, similar disposition and distribution may occur in humans.

Administration, Topical↗

Determination of 228Ra, 226Ra and 224Ra in natural water via adsorption on MnO2-coated discs.

A fast procedure based on sorption of Ra on MnO2 coated polyamide discs is presented for determination of radium isotopes (i.e. 228Ra, 226Ra, 224Ra) in aqueous samples. The sample discs can be used directly for low-level alpha-spectrometry without the need for further separation and preparation methods to produce planar sample sources. While the activity of alpha-emitting 224Ra and 226Ra can be determined during a first measurement, beta-emitting 228Ra is obtained via ingrowth of the progeny 228Th on the same sample disc after a standing time of about six months. Calculations are presented for optimizing the analytical accuracy as well as for predicting the sorption yield or chemical recovery of radium on the sample disc as a function of exposure time because the sorption uptake proceeds with first-order kinetics. The analyses can be carried out on small samples of 0.5-11 and, for long counting times of one week and use of high-purity silicon surface barrier detectors, a detection limit of 0.15 mBq l-1 is obtained for 226Ra. Since the half-life of 224Ra is only 3.7 d and since 228Th (as a measure for 228Ra) is built up only partially on the sample disc, a slightly higher detection limit of 0.24 mBq l-1 results for the latter isotopes. The procedure is therefore sufficiently sensitive to allow the investigation of Ra isotope relationships in aquifers at typical environmental levels.

Adsorption↗

Testing for drugs in hair. Critical review of chromatographic procedures since 1992.

Up to now, more than 50 pharmaceuticals or drugs of abuse have been reported to be detectable in hair after oral or parenteral administration. The present paper reviews the literature devoted to drug testing in hair that has been published since 1992. Procedures for the detection of opiates, cocaine, amphetamines and cannabis in hair are described in detail. In particular, the papers on benzodiazepines show an increasing number of procedures using negative chemical ionisation with GC-MS and diode array detection with HPLC in hair analysis. For the most important benzodiazepines, diazepam and flunitrazepam, reliable methods now exist. On the other hand, the problem of the detecting tetrahydrocannabinol metabolites using different techniques is not yet solved. Some progress is observed in the detection of low dose drugs, like fentanyl and its derivatives or LSD. For most of the analyses using chromatographic techniques, the main data on sample preparation and analytical determinations are listed. Some new findings, based on the experience of the authors, are also added.

Amphetamines↗

Simultaneous determination of amiloride hydrochloride and hydrochlorothiazide in synthetic samples and pharmaceutical formulations by multivariate analysis of spectrophotometric data.

The use of multivariate spectrophotometric calibration for the simultaneous analysis of synthetic samples and commercial tablet preparations containing hydrochlorothiazide (HCT) and amiloride hydrochloride (AMH) is reported. Partial least squares (PLS-1) analysis of electronic absorption spectral data allowed the rapid and accurate resolution of mixtures in which the analyte ratios were approximately 10:1, without the need of a previous separation step and without interference from other sample constituents. The method, validated by the analysis of synthetic mixtures of both drugs, where accuracy over the linear working range as well as inter- and intra-assay precision were determined, was used in the concentration ranges of 21.7-30.4 mg l(-1) for HCT and 1.8-3.0 mg l(-1) for AMH. The proposed method was successfully applied to the evaluation of the stability of the stock solutions of the analytes in MeOH-H(2)O and to the elaboration of drug dissolution profiles of commercial tablets, results being concordant with those furnished by the USP technique. The method was also employed for the determination of drug content in two different pharmaceutical formulations, providing results that were in excellent agreement with those obtained by HPLC.

Amiloride↗

A new method for the determination of trichloroacetic acid in spruce foliage and other environmental media.

Trichloroacetic acid (TCAA) is a phytotoxic chemical, present throughout the environment. The majority of methods for analysis of TCAA require chemical derivatisation and multiple extraction steps prior to analysis by gas-chromatography. Here, a new analytical method for TCAA determination in environmental matrices is reported. The method is based on a modified Nielsen-Kryger steam distillation that combines into one 1 h reflux the thermal decarboxylation of TCAA to CHCl3 and the partitioning and concentration of the CHCl3 into 5 ml of hexane, which is analysed by GC. Sample preparation is minimal and no matrix standard additions are required. The background CHCl3 in the sample is removed prior to extraction by degassing the solution for 1 h with nitrogen. Optimisation of the method gave recoveries from three separate solutions of 0.31 ppb aqueous TCAA standards of 93 +/- 15% (n = 9), 110 +/- 9% (n = 9) and 105 +/- 11% (n = 6). The extraction method has been compared with a decarboxylation and headspace GC method for determination of TCAA in Sitka spruce needles. No significant difference in TCAA concentration or replicate precision between the two methods was observed.

Caustics↗

A rapid and accurate method for the determination of plutonium in food using magnetic sector ICP-MS with an ultra-sonic nebuliser and ion chromatography.

In the event of a nuclear incident it is essential that analytical information on the distribution and level of contamination is available. An ICP-MS method is described which can provide data on plutonium contamination in food within 3 h of sample receipt without compromising detection limits or accuracy relative to traditional counting methods. The method can also provide simultaneous determinations of americium and neptunium. Samples were prepared by HNO3 closed-vessel microwave digestion, evaporated to dryness and diluted into a mobile phase comprising 1.5 M HNO3 and 0.1 mM 2,6-pyridinedicarboxylic acid. A commercially available polystyrene-divinylbenzene ion chromatography column provides on-line separation of 239Pu and 238U reducing the impact of the 238U1H interference. Oxidation of the sample using H2O2 ensures all Pu is in the Pu(+4) state. The oxidation also displaces Np away from the solvent front by changing the oxidation state from Np(+3) to Np(+4) and produces the insoluble Am(+4) ion. Simultaneous Pu, Am and Np analyses therefore require omission of the oxidation stage and some loss of Pu data quality. Analyses were performed using a magnetic sector ICP-MS (Finnigan MAT Element). The sample is introduced to the plasma via an ultrasonic nebuliser-desolvation unit (Cetac USN 6000AT+). This combination achieves an instrumental sensitivity of 238U > 2 x 10(7) cps/ppb and removes hydrogen from the sample gas, which also inhibits the formation of 238U1H. The net effect of the improved sample introduction conditions is to achieve detection levels for Pu of 0.020 pg g(-1) (4.6 x 10(-2) Bq kg(-1)) which is significantly below 1/10th of the most stringent EU (European Union) legislation, currently 0.436 pg g(-1) (1 Bq kg(-1)) set for baby food. The new method was evaluated with a range of biological samples ranging from cabbage to milk and meat. Recovery of Pu agrees with published values (100% +/- 20%).

Chromatography, Ion Exchange↗

Recent advances in electrode materials for electrochemical detection of zearalenone.

Zearalenone (ZEN) is an estrogenic mycotoxin commonly found in cereals, animal feed, and processed foods, making it an important concern for food safety and public health. Conventional chromatographic and immunological methods can detect ZEN; however, they often require expensive instruments, lengthy sample preparation, and skilled personnel, which restrict their use for rapid and on-site testing. Electrochemical sensors have attracted enormous interest of the scientific community because of their high sensitivity, rapid response, low cost, miniaturization potential, and compatibility with portable systems. The analytical performance of the electrochemical sensors is strongly influenced by electrode materials, morphology, conductivity, porosity, surface functionality, and the efficiency of bioreceptor immobilization. Despite several reviews on mycotoxin detection, a systematic assessment connecting electrode-material design, modification strategies, sensing mechanisms, and electroanalytical performance specifically for ZEN sensing remain limited. This review critically evaluates recent advances in metal oxides, carbon-based materials, metal-organic- and covalent organic frameworks, MXenes, polymers, and hybrid composites for electrochemical ZEN detection. Particular attention has been given to their roles in electron transfer, analyte enrichment, selectivity, and real-sample analysis. The review also compares the major limitations of current sensing systems, including complex fabrication, matrix interference, insufficient long-term stability, poor inter-electrode reproducibility, and limited scalability. Finally, future directions for developing robust, cost-effective, portable, and commercially viable ZEN sensors are discussed.

Journal Article↗

Determination of cardiac troponin I for the auxiliary diagnosis of acute myocardial infarction by anodic stripping voltammetry at a carbon paste electrode.

An electrochemical immunoassay for cardiac troponin I (cTnI) combining the concepts of the dual monoclonal antibody "sandwich" principle, the silver enhancement on the nano-gold particle, and the anodic stripping voltammetry is described. Four main steps were carried out to obtain the analytical signal, i.e., electrode preparation, immunoreaction, silver enhancement, and anodic stripping voltammetric detection. A linear relationship between the anodic stripping peak current and concentration of cTnl from 1 to 20 ng/ml and a limit of detection of 0.8 ng/ml were obtained. The established method was tested by determining cTnI in acute myocardial infarction (AMI) samples using enzyme-linked immunoadsorbent assay (ELISA) for comparison analysis, and good results were obtained.

Antibodies, Monoclonal↗

Electrochemical determination of minoxidil in different pharmaceutical formulations by flow injection analysis.

The electrochemical behavior and amperometric-FIA quantification of minoxidil at a glassy carbon electrode is described. The procedure is based on electrochemical oxidation at 0.800 V (vs. Ag/AgCl/NaCl(3 M) in a phosphate buffer solution. Minoxidil was determined over the range 1 x 10(-7) - 1 x 10(-4) M. Different analytical parameters and electrode stability were analyzed to obtain the best electrode performance. The optimal conditions were: working potentials, 0.800 V; flow rate, 0.74 mL min(-1); and solution pH 7.0. This system allowed a sampling rate of 120 samples per hour without any pretreatment. The proposed method was used for minoxidil quantification in pharmaceutical preparations with satisfactory results. The accuracy of FIA-amperometric method was established by a comparison with the conventional UV determination technique using a paired t-test indicating the absence of systematic errors.

Electrochemistry↗