A simple nucleic acid hybridization/latex agglutination assay for the rapid detection of polymerase chain reaction amplicons.

We have developed a new method for the detection of nucleic acid hybridization, based on a simple latex agglutination test that can be evaluated by the unaided eye. Nucleic acid, e.g., a polymerase chain reaction (PCR) product, is denatured and incubated with polystyrene beads carrying covalently bound complementary oligonucleotide sequences. Hybridization of the nucleic acids leads to aggregation of the latex particles, thereby verifying the presence of target sequence. The test is performed at room temperature, and results are available within 10 min. As a proof of principle, the hybridization/latex agglutination assay was applied to the detection of purified PCR fragments either specific for Salmonella spp. or a synthetic sequence, and to the detection of Salmonella enterica in artificially contaminated chicken samples. A few nanograms of purified PCR fragments were detectable. In artificially contaminated chicken samples, 3 colony-forming units (cfu)/25 g were detected in one of three replicates, and 30 cfu/25 g were detected in both of two replicates when samples for PCR were taken directly from primary enrichment, demonstrating the practical applicability of this test system. Even multiplex detection might be achievable. This novel kind of assay could be useful for a range of applications where hybridization of nucleic acids, e.g., PCR fragments, is to be detected.

Animals↗

Latex agglutination test for the detection of urinary antigens in visceral leishmaniasis.

This paper describes a new latex agglutination test ('KATEX') for the detection of leishmanial antigen in the urine of patients with visceral leishmaniasis. In preliminary laboratory trials, using urine collected from well-defined cases and controls from Brazil, Yemen and Nepal, the test had 100% specificity and a sensitivity between 68 and 100%. When used in a time-course experiment in cotton rats infected with Leishmania donovani, the test became positive 1 week after inoculation and antigen levels in urine declined rapidly after chemotherapy (the test was negative before the end of the course of treatment). Finally, in an integrated study performed in Sudan, KATEX was compared to microscopy and four different serological tests in a group of 73 patients having presented with clinical manifestations suggestive of visceral leishmaniasis. Compared to microscopy, KATEX performed better than any single serological test in predicting positivity and a particularly good result was obtained by combining KATEX and the direct agglutination test (DAT).

Animals↗

Rapid detection of vaginal colonization with group B streptococci by means of latex agglutination.

Latex agglutination testing for colonization of the vagina with group B streptococci was carried out in 1100 patients. Samples underwent latex testing after 8 to 12 hours of preincubation in selective growth medium. This technique allowed a sensitivity of 91.8% and specificity of 97.6%. This study demonstrates the usefulness of latex agglutination testing in the detection of vaginal colonization with group B streptococci.

Female↗

Circulating sperm-agglutinating antibodies in azoospermic men with congenital bilateral absence of the vasa deferentia.

Congenital bilateral absence of the vasa deferentia has been found to be the cause for azoospermia in 101 patients who have been examined in our urologic practice since 1956. This represents approximately 2% of the 5112 patients seen during that time because of problems relating to infertility. Of these 101 men, 29 have had their sera tested for the presence of circulating sperm-agglutinating antibodies. The Shulman15 modification of the macroscopic gelatin sperm-agglutination test of Kibrick et al6 was used. None of these patients had had testicular biopsy. Significantly high titers (1:32 or greater) of antibodies were found in 18 (62.1%) men, low titers (1:16 or less) in five (17.2%), and no antibodies in six (20.7%).

Agglutinins↗

Detection of meningitis antigens in buffer and body fluids by ultrasound-enhanced particle agglutination.

The standard test card agglutination of antibody-coated latex by Neisseria meningitidis. Streptococcus group B, Haemophilus influenzae type b and Streptococcus pneumoniae antigens has been compared with a technique involving local concentration of the coated latex in an ultrasonic standing wave. The detection of positive control antigen was enhanced, compared with the test-card procedure, over a 16 to 64 fold range on exposure to ultrasound. Sample filtration eliminated non-specific agglutination on ultrasonic exposure of latex in control serum, urine or concentrated urine. Tests of meningitis patient body fluids showed increased detection of antigen with ultrasound for CSF (11/14 > 7/14) serum (8/13 > 3/13) and concentrated urine (8/17 > 2/17) compared to test card assays. The ultrasound detection of antigen in serum or concentrated urine was comparable to that achieved with CSF on test cards. Serum dilution experiments showed that ultrasound could detect antigen in serum over a 1000 fold concentration range.

Antigens, Bacterial↗

Evaluation of the Eiken latex agglutination test for anti-Toxoplasma antibodies and seroprevalence of Toxoplasma infection among factory workers in Addis Ababa, Ethiopia.

Sera from 170 factory workers aged 18-45 years enrolled in a pilot study of human immunodeficiency virus 1 (HIV-1) infection in Addis Ababa, Ethiopia, were screened for anti-Toxoplasma immunoglobulin G antibodies by the Sabin-Feldman test (reference standard) and the Eiken latex agglutination test (under evaluation for use in developing countries). Based on the Sabin-Feldman test, the prevalence of anti-Toxoplasma antibodies was 80.0% (95% confidence interval 73.9-86.1%). The sensitivity and specificity of the Eiken latex agglutination test were 96.3% and 97.1%, respectively, showing its validity for the detection of anti-Toxoplasma antibodies. The prevalence of antibodies did not differ between individuals infected and uninfected with HIV-1 (74.2% versus 83.3%, P > 0.05). However, antibody titres were higher in HIV-infected persons than in those who were uninfected (P < 0.001). Based on these findings, we expect that toxoplasmic encephalitis will be a common opportunistic infection among HIV-infected Ethiopians, and chemoprophylaxis with co-trimoxazole may be beneficial to those with low CD4+ T cell counts. The prognostic significance of high titres of anti-Toxoplasma antibodies remains to be established among Ethiopian HIV-infected individuals.

Adolescent↗

Ultrasonic wave action upon the red blood cell agglutination in vitro.

The ultrasonic wave action upon immune red blood cell (RBC) aggregation in vitro was investigated by means of the elastic light-scattering method. The RBC agglutination process in the ultrasonic wave presence was analysed as a function of irradiation time, the antiserum series, the whole blood and antiserum dilution degree and blood group types. It was experimentally shown that the ultrasonic irradiation accelerated the agglutination reaction in the blood and antiserum mixture. The sedimentation process showed a gain in the resolution of the optical method's ability to detect the induced RBC complex formation. It revealed that the ultrasonic application led to significant diagnostic test time shortening. The results may be used to develop new diagnostic techniques and devices.

Blood Grouping and Crossmatching↗

Concanavalin A agglutination of bladder cells of rats treated with bladder carcinogens; a rapid new test to detect bladder carcinogens.

N-butyl-N-(4-hydroxybutyl)nitrosamine (BBN), which is a potent, specific bladder carcinogen in rats, and its related compounds were orally administered to rats for 1 week. The bladder cells were isolated by the treatment with EDTA and sonication and they were subjected to agglutination assay by concanavalin A (Con A). Bladder cells obtained from rats treated with BBN, N-butyl-N-(3-carboxypropyl)nitrosamine (BCPN), N-ethyl-N-(4-hydroxybutyl)nitrosamine (EHBN) and N-butyl-N-(2-hydroxyethyl)nitrosamine (BHEN) were agglutination-positive, while those cells treated with N-tert-butyl-N-(4-hydroxybutyl)-nitrosamine (t-BBH) and N-butyl-N-(3-hydroxypropyl)nitrosamine (BHPN) were negative. Results obtained by this method were highly correlated with the known carcinogenicity of BBN and its analogues. Therefore, this method could be used for rapid screening of bladder carcinogens.

Animals↗

Enzyme-linked immunosorbent assay and latex agglutination inhibition reaction test for morphine in urine.

An enzyme-linked immunosorbent assay (ELISA) and a latex agglutination inhibition reaction test (LAIRT) for morphine have been established. Rabbits were immunized with 3-carboxymethylmorphine-bovine serum albumin (BSA) conjugate to obtain anti-morphine antibody and IgG fraction of the antiserum was used as an antibody. In ELISA, 3-carboxymethylmorphine-alkaline phosphatase (ALP) conjugate and antibody adsorbed on polystyrene microtiter wells were used. The enzyme activity of antibody bound ALP was measured with the enzyme cycling method. The range of morphine measurable by ELISA was 6-600 pg/well and the analysis time for 96 wells was 90 min. In LAIRT, 3-carboxymethylmorphine-rabbit serum albumin (RSA) conjugate and the antibody were bound to latex particles covalently to prepare latex-antigen and latex-antibody reagent, respectively. The agglutination reaction with latex-antigen and latex-antibody reagents was inhibited by 0.2 microgram morphine/ml urine and the analysis time for six samples on one glass slide was 20 min. The urine samples of 47 suspected abusers were analyzed by ELISA and LAIRT and the results were compared with those of the enzyme-multiplied immunoassay technique (EMIT) and gas chromatography/mass spectrometry (GC/MS). Both ELISA and LAIRT for morphine seem to be suitable for the screening of urine samples.

Animals↗

Evaluation of the MycoAKT latex agglutination test for rapid diagnosis of Mycobacterium avium complex infections.

Rapid diagnosis of Mycobacterium avium complex (MAC) bacteremia is important for management of patients with the acquired immunodeficiency syndrome who have disseminated MAC. The purpose of this study was to determine the reliability of the MycoAKT latex agglutination test for direct detection of MAC in positive mycobacterial blood cultures. First, colonies of isolates of previously identified mycobacteria, including 35 MAC, were tested. Of the 55 isolates evaluated, 33 were identified as MAC by the latex test, including 31 of the known MAC and 2 M. chelonae (sensitivity, 88.6%; specificity, 90.0%). Second, broth from 20 ESP II and 20 BACTEC 12B bottles seeded with isolates of MAC were tested. Aliquots from 19 (95%) ESP II cultures and 16 (80%) 12B cultures were positive by the latex test. In phase 3, broth from 115 signal-positive ESP II blood cultures were tested by latex agglutination. Forty-three subcultures from these bottles grew mycobacteria (41 MAC and 2 Mycobacterium tuberculosis complex); the remainder grew no organisms. Broth from 40 of the blood cultures (39 that grew MAC and 1 from which no organisms were recovered) were latex positive; thus, the sensitivity, specificity, and positive and negative predictive values of the latex test for direct identification of MAC in ESP II blood cultures were 95.1, 98.6, 97.5, and 97.3%, respectively. The mean time to detection of MAC was 14.6 days (range, 6-34 days) with the direct latex test, compared with 18.3 days (range, 9-36 days) with subculture and probe (p < 0.05).

AIDS-Related Opportunistic Infections↗

Discrepant results with a latex agglutination test in the assessment of cytomegalovirus antibody status of cardiac transplant donors.

The cytomegalovirus (CMV) antibody status of 79 cardiac transplant recipients and their respective donors was determined by a latex-agglutination technique and by a CMV IgG ELISA technique on the same samples. Although good agreement between the two methods was found in recipient samples the latex method produced significantly more positive results in donor samples than did the ELISA test. Clinical and serological follow-up of the patients concerned over the first 6 months after transplantation suggested that the ELISA results were correctly predictive of donor transmitted primary CMV infection and that, therefore, the latex test was producing false positive readings. Further investigation is needed to discover the reason for these discrepancies. The use of donor samples taken at the time of organ retrieval may have prejudiced the latex test results. Until these problems are resolved it is suggested that the latex agglutination technique should not be the sole method adopted to assess donor CMV antibody status.

Antibodies, Viral↗

Slide agglutination test for the diagnosis of pulmonary and extra-pulmonary tuberculosis.

OBJECTIVE: Evaluation of a 2 min slide agglutination test to detect the presence of antibodies directed against Mycobacterium tuberculosis antigens. DESIGN: The test utilizes solible antigens extracted from a cultivable new species of non-pathogenic saprophytic mycobacterium, Mycobacterium w, which shares antigenic determinants with M. tuberculosis. The soluble antigens are covalently linked to carboxylated polystyrene latex beads. RESULTS: The sensitivity of the assay was increased from 78% (reported earlier), to 90.2% for pulmonary tuberculosis and 85.7% for extra-pulmonary tuberculosis. The specificity of the test was determined by testing the sera of apparently healthy controls, and patients with other respiratory tract infections and rheumatoid arthritis. Among the apparently healthy controls, 7.3% tested positive. None of the sera from the patients with other diseases gave positive agglutination. CONCLUSION: This simple and rapid technique could be suitable for mass screening for pulmonary and extrapulmonary tuberculosis.

Adolescent↗

The acquisition of agglutinating languages: converging evidence from Tamil.

The acquisition of verb inflections in Tamil, an agglutinating language, was investigated in three 2-year-old children. The findings revealed a high percentage use of verb inflections indicating tense, aspect, modality, person, number and gender by all three children. Explanations for this early, almost error-free acquisition are discussed in terms of the facilitating properties of agglutinating languages.

Child, Preschool↗

Effects of anti-thrombospondin monoclonal antibodies on the agglutination of erythrocytes and fixed, activated platelets by purified thrombospondin.

A monoclonal antibody (Mab) has been raised against native thrombospondin (TSP), the endogenous lectin of human platelets, that inhibits the hemagglutination of trypsinized, glutaraldehyde-fixed human erythrocytes by purified TSP. This Mab, designated A2.5, also inhibits the agglutination of fixed, activated platelets by TSP. Mab A2.5 immunoprecipitates a 25-kilodalton (kDa) peptide from chymotryptic digests of TSP that is not disulfide bonded to any other region of the TSP molecule. This fragment represents the previously characterized heparin binding domain of TSP [Dixit, V.M., Grant, G.A., Santoro, S.A., & Frazier, W.A. (1984) J. Biol. Chem. 259, 10100-10105]. In agreement with this assignment, heparin inhibits the binding of Mab A2.5 to TSP. Another Mab, designated C6.7, also blocks TSP-mediated hemagglutination, yet has no effect on the agglutination of fixed, activated platelets by TSP. This Mab has been shown to inhibit the thrombin-stimulated aggregation of live platelets and to immunoprecipitate an 18-kDa fragment from chymotryptic digests, which is distinct from the heparin binding domain [Dixit, V.M., Haverstick, D.M., O'Rourke, K.M., Hennessy, S.W., Grant, G.A., Santoro, S.A., & Frazier, W.A. (1985) Proc. Natl. Acad. Sci. U.S.A. 82, 3472-3476].

Antibodies, Monoclonal↗

Polyacrylamides bearing pendant alpha-sialoside groups strongly inhibit agglutination of erythrocytes by influenza A virus: multivalency and steric stabilization of particulate biological systems.

An alpha-sialoside linked to acrylamide by a short connector (5-acetamido-2-O-(N-acryloyl-8-amino-5-oxaoctyl)-2,6-anhydro-3,5-d ideoxy-D-galacto-alpha-nonulopyranosonoic acid, 1) was prepared. Compound 1 formed high molecular weight copolymers with acrylamide, derivatives of acrylamide, and/or vinylpyrrolidone upon photochemically-initiated free radical polymerization. Those copolymers for which the substituents on the acrylamido nitrogen were small inhibited the agglutination of chicken erythrocytes induced by influenza virus (X-31 (H3N2); a recombinant strain of A/Aichi/2/68 (H3N2) and A/Puerto Rico/8/34 grown in chicken eggs). The inhibitory power of the polymers depended strongly on the conditions of polymerization and the sialic acid content of the polymer. The strongest inhibitors were copolymers (poly(1-co-acrylamide)) formed from mixtures of monomer containing [1]/([1] + [acrylamide]) approximately 0.2-0.7; these copolymers inhibited hemagglutination 10(4)-10(5) times more strongly than did similar concentrations of alpha-methyl sialoside (calculated on the basis of the total concentration of individual sialic acid groups in the solution, whether attached to polymer or present as monomers). Samples polymerized in the presence of low concentrations of cross-linking reagents (bis(acrylamido)methane, BIS, and 2,2'-bis(acrylamido)ethyl disulfide, BAC) also showed increased inhibition (10-10(3)-fold relative to monomers), but their use was limited by their poor solubility. Sterically demanding substituents on any position of the acrylamide component (substituents attached to the vinyl group or N-alkyl groups that are larger than hydroxyethyl) reduced the inhibitory power of the polymer. A 1H NMR assay and a fluorescence depolarization assay showed that poly(1-co-acrylamide) bound to a solubilized trimeric form of the viral receptor for sialic acid (bromelain cleaved hemagglutinin, BHA), less tightly than 1, on a per sialic acid basis. A similar result was also obtained with a model system comprising lactic dehydrogenase (a tetramer) and polymeric derivatives of oxamic acid: that is, poly((28, 29, 30, or 31)-co-acrylamide) had a higher inhibition constant for tetrameric lactic dehydrogenase than did the corresponding monomers (28, 29, 30, or 31) on a per oxamate basis. Poly(1-co-acrylamide) is, in principle, capable of inhibiting the agglutination of erythrocytes by several mechanisms: (1) entropically enhanced binding of the polymer (acting as a polyvalent inhibitor) to the surface of the virus; (2) steric interference of the approach of the virus to the surface of the erythrocyte by a water-swollen layer of the polymer on the surface of the virus; (3) aggregation of the virus induced by the polymer.(ABSTRACT TRUNCATED AT 400 WORDS)

Acrylic Resins↗

Inverse correlation between IgG-antihinge region and antierythrocyte autoantibody in chronic benign and malignant cold agglutination.

Previous reports provided evidence of an immunosuppressive role of natural anti-F(ab')2 antibodies. If suppressive anti-F(ab')2 antibodies also regulated the autoantibody production in cold agglutination, one would expect high titers of anti-F(ab')2 to be associated with low titers of cold agglutinins. Indeed, our previous studies revealed an inverse correlation between IgG-anti-F(ab')2 and cold agglutinins. Many previous experiments focused on anti-F(ab')2 of an antiidiotypic nature. Recent epitope mapping showed that anti-F(ab')2 of healthy persons is not an antiidiotype but recognizes a hinge region sequence. We attempted to answer the question whether this IgG-antihinge antibody is responsible for the previously described association between anti-F(ab')2 and cold agglutinins. IgG-antihinge and IgG-anti-F(ab')2 antibody was determined and statistically analyzed in the serum of 334 patients with cold agglutination. Our experiments revealed a strong correlation between the concentrations of antihinge and the previously described anti-F(ab')2 antibody. The anti-F(ab')2 activity was competitively inhibited by a synthetic hinge peptide. Moreover, patients with high antihinge titers had low cold agglutinin titers, and vice versa. A stratification according to cold agglutinin specificity and disease etiology showed that the inverse correlation is present only in anti-I and anti-i patients suffering from monoclonal B-lymphocyte proliferation. In conclusion, our results confirm the correlation previously described for anti-F(ab')2 antibody and antierythrocyte autoantibody and define for the first time an association between an idiotype-independent anti-IgG autoantibody and cold agglutinin.

Adult↗

Agglutination of peripheral blood lymphocytes from cancer patients and not from healthy controls, with the F2A1 histone fraction.

A simple, rapid histone agglutination test (HAT) is described. It consists of incubation in microplates or in microtubes of blood lymphocytes isolated from cancer patients and patients with non-malignant diseases with microquantities of histone fraction F2A1. Positive reaction is shown by massive agglutination of lymphocytes of the patients tested (126 subjects): this test was positive in 76% of cases. All controls (59 subjects) were negative.

Adolescent↗

Polymer agglutination-based piezoelectric immunoassay for the determination of complement III.

A piezoelectric immunoassay technique, which is based on the detection of agglutination of antibody- or antigen-bearing polymer by an immunoreaction using a piezoelectric quartz crystal, has been developed for the determination of complement III (C3). Anti-C3 antibodies were physically adsorbed onto the carboxymethyl cellulose polymer by hydrogen bonds. The agglutination of the (anti-C3 antibody)-bearing polymer by immunoreaction caused a viscosity change of the solution, which could be monitored by a piezoelectric quartz crystal. The effect of experimental conditions such as the polymer concentration, the antibody dilution ratio and the reaction temperature on the frequency response were investigated. The linear ranges for C3 concentration determined by the end-point method and the initial rate method were 22.0-43.2 micrograms ml-1 and 22.0-49.1 micrograms ml-1, respectively. Other antigens presenting in serum did not interfere with the determination of C3. Analytical results of ten clinical specimens obtained using the developed technique were in satisfactory agreement with those given by the rate diffusion turbidimetry. With a simple regeneration method devised, the crystal can be used repeatedly with acceptable reproducibility.

Complement C3↗