Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

Effect of bilateral asymmetric tooth clenching on load distribution at the mandibular condyles.

The effects of balancing-side tooth contacts on temporomandibular joint loads are unclear. We used a 3-D computer model to calculate the magnitude and direction of temporomandibular reaction forces during simulated clenching on interocclusal acrylic resin shims and between natural teeth. Muscle tensions were proportioned according to the task modeled. Working-side tooth contacts included the canine alone, as well as group function, and occlusal loads were progressively shifted toward a posterior contralateral simple balancing contact. In the acrylic resin shim experiments, group function with simple balancing contact yielded the highest forces at the load point and at both temporomandibular joints. Movement of the occlusal load toward the balancing side produced greater, anteriorly oriented forces on the working condyle. For natural teeth, changes in the angle of resultant tooth force (simulating facet angulation) greatly influenced condylar forces. As the occlusal load moved toward the balancing side, greater and more laterally oriented forces were produced on the balancing condyle. Unilateral clenching on the canine produced the least condylar and bite forces. The simulation involving natural teeth offers a possible explanation for deviations in form and osteoarthrosis at the temporomandibular joints.

Acrylic Resins↗

Digital assessment of occlusal wear patterns on occlusal stabilization splints: a pilot study.

STATEMENT OF PROBLEM: If masticatory load distribution is task-dependent, then the pattern of wear on an acrylic resin occlusal splint over time may affect clinical outcome. PURPOSE: This pilot study quantitatively assessed posterior wear after 3 months on the occlusal surfaces of maxillary stabilization splints. MATERIAL AND METHODS: Subjects with known history of nocturnal bruxism were given heat-cured full-arch acrylic resin occlusal stabilization splints to be worn nocturnally for 3 months. Splint occlusion was adjusted at appliance delivery and was refined at the baseline session 1 to 2 weeks later. No further adjustment of the splint surface was performed during the 3-month study period. Sequential impressions of the splint occlusal surface provided epoxy resin models that were digitized and analyzed through specialized software. Changes in the digitized splint surface from baseline to 3 months allowed comparison of wear facets between splint sides and among tooth locations. RESULTS: Splint wear was asymmetric between sides and uneven between dental locations. CONCLUSIONS: For full coverage occlusal splints, the appliance wear phenomenon can be site specific and, if left undisturbed, may yield two extremes of high wear and a zone of low wear in-between.

Acrylic Resins↗

Fatigue resistance of removable orthodontic appliance reinforced with glass fibre weave.

The aim of this study was to measure the fatigue resistance of fibre-reinforced composite (FRC) reinforced polymeric parts of a removable orthodontic appliance beside the clasp. The effect of quantity and position of FRC-reinforcement were investigated. In addition, the influence of water storage on the fatigue properties was determined. The test specimens for eight groups (n=6) were manufactured from autopolymerizing acrylic resin. Polymethylmethacrylate pre-impregnated woven glass fibre was used as reinforcement of acrylic resin specimens at the region of steel wire clasp. The test specimens of the control group were not reinforced. In the second group, the test specimens were reinforced with one fibre layer (thickness: 0.06 mm) on the tension side, and in the third and fourth group with two fibre layers. Fatigue resistance was measured by applying repeated bending force to the clasp. The highest fatigue resistance values were achieved when the test specimens were fibre-reinforced with two fibre layers. The lowest fatigue resistance values resulted when the test specimens were not reinforced (P=0.046, anova). Water storage had a tendency to decrease the fatigue resistance in all fibre reinforced test specimen groups. The results suggest that use of the woven polymer pre-impregnated glass FRC-reinforcement increases the fracture resistance of orthodontic appliance made of acrylic polymer.

Absorption↗

Cast posts that fit at first try.

The following article describes a procedure that permits the retention of a cast post that will fit passively in the canal at first try. By means of an indirect method, an elastic cast was poured in the master impression and an exact duplicate of the future dowel was formed with self-curing acrylic resin. A stone cast made from a second pour of the impression was then used to adjust the pattern in the laboratory. Posts made with the use of this system routinely sit passively in the root canal without the need of adjustments at the chair. The interval employed in obtaining and adjusting an acrylic resin pattern mentioned in the above way represents less time and effort than trying to make a cast fit in the canal, especially in the case of patients who require multiple posts in the same arch.

Acrylic Resins↗

A matrix procedure for reproducing natural or carved tooth contours in porcelain laminate veneers.

A procedure is described for making porcelain laminate veneers by using a preformed acrylic resin matrix to reproduce the original tooth form and surface texture. The procedure can be modified to allow alterations to the original contours by adding wax to, or carving, a preliminary cast. A silicone impression is made of either the teeth preoperatively or the altered cast and is used to construct a translucent heat-cured acrylic resin matrix. The matrix is fitted to the working cast and used to condense the porcelain for veneers. A patient's restorations are used to illustrate the procedure.

Acrylic Resins↗

Adhesion of elastomeric impression materials to trays.

The tensile and shear adhesive bond strengths of two addition cured silicones (Provil and Express) and a polyether (Impregum) impression material to brass, poly(methylmethacrylate) and visible light-cured (VLC) tray resin were determined. Adhesive application significantly increased the bond strength; Provil and Express adhered most strongly to brass; whilst the Impregum-VLC combination produced the strongest bond. Indeed, VLC resin generated greater adhesion than acrylic resin. Exchanging the adhesives specified for each silicone material generally resulted in higher bond strengths. No correlation was established between speed of separation of the test surfaces and bond strength. For optimum clinical performance, the impression material (adhesive) tray material giving the highest bond strength should be utilized.

Acrylic Resins↗

Micromechanical versus chemical bonding between CoCr alloys and methacrylate resins.

INTRODUCTION: As adhesive systems for bonding to metals have developed in dentistry, considerable importance is attached to the preparation of the metal alloy for both mechanical and chemical bonding. Different grit sizes when sandblasting Cobalt Chromium (CoCr) will provide a different three-dimensional surface for bonding. Previous reports have shown that 4-Methacryloyloxyethyl trimellitic anhydride (4-Meta) resins offer high bond strengths to CoCr alloy, with various surface preparations providing varying bond strengths. The relevance of this to bond strength was assessed. OBJECTIVES: The aim of the study was to evaluate the importance of grit size of alumina in the preparation of CoCr alloy and to determine the effect on the tensile bond strength of four different acrylic resins to the CoCr alloy. METHODS: Ten specimens were prepared within each group of four resins. Four grit sizes were assessed, 50, 110, 250 microm, and a range from 180 to 330 microm. The specimens were tested both within one day of production after storing at 37 degrees C in phosphate-buffered saline for seven days and after thermocycling. RESULTS: Grit size resulted in a change in average contact surface area available for bonding. A significant difference (p < 0.01) existed in bond strengths between each of the materials, but no significant difference (p = 0.0673) was determined when different grit sizes were included. SIGNIFICANCE: It was concluded that grit size determined the available contact surface area of CoCr alloy for bonding but did not determine the bond strength that could be achieved between acrylic resins and CoCr alloy as a result of the poor adaptation of the resin to the complex surface topography.

Acrylic Resins↗

Prosthetic management of large nasal septal defects.

Large nasal septal defect is defined as a defect that exceeds in size a stretched nostril. Large nasal septal defects cannot be closed by hard acrylic resin nasal septal obturators because of access and path-of-insertion problems. However, obturation can be achieved by construction of a nasal stent that fits into one of the nasal cavities. This article describes a procedure used to manage a large nasal septal defect with an intranasal heat-processed acrylic resin stent. The medial wall of the stent indirectly allows for the partition of the two nasal cavities. The stent is rendered patent to allow for comfortable breathing. The impression making and construction of these stents is not difficult. These nasal stents indirectly separate the two nasal cavities and effective obturation of large nasal septal defects is achieved.

Acrylic Resins↗

Plaque accumulation on crowns made of various materials.

The rate of plaque accumulation on various materials used for fixed prostheses was investigated, and the composition of plaque formed on each surface was evaluated. Enamel, metal, acrylic resin, and porcelain surfaces were studied. Amounts of plaque that formed on the teeth and fixed restorations were scored using the method of Silness and Loe. Different individuals formed plaque at different rates, and the character and quantity of the plaque was different on the various materials. In a second study, acrylic resin, metal, and porcelain crowns were made for each of 10 patients. The amount of plaque absorbed onto each material after 1, 3, and 24 hours was recorded using scanning electron microscopy. The samples of dental plaque at 24 hours on each type of crown material were collected and investigated in a CHN Analyzer 184, revealing differences in the chemical composition of plaque adsorbed onto different surfaces. The results of SEM examination and biochemical analysis are presented.

Acrylic Resins↗

Effects of season on kidney morphology in house sparrows.

Seasonal variability in kidney morphology of the house sparrow Passer domesticus was examined using light microscopy. Sparrows were captured from the wild in winter, spring, summer and autumn. The kidneys were perfused with half-strength Karnovsky's fixative and processed for light microscopy by embedding in either paraffin wax or JB4 acrylic resin. Absolute volumes of the kidneys, their components (cortex, medulla and blood vessels), components of the nephron (renal corpuscles, proximal tubules, loops of Henle, distal tubules and collecting ducts) and the capillaries surrounding the nephron were quantified using stereology. Tissue processed in paraffin wax had a mean shrinkage of 17.7 % compared with 10.1 % in JB4 resin. Absolute volumes of the kidneys and nephrons were compared statistically between tissue processing methods and among seasons. Absolute volumes of the structures within the kidneys were not significantly different between treatments or among seasons. Within the nephron, the only measured variables to show significant differences were the absolute volumes of the distal tubules and cortical collecting ducts between tissue processing treatments. Thus, kidney morphology was relatively unaffected by changes in season. In addition, the results show that embedding tissue using acrylic resin causes less shrinkage, and it should therefore be the preferred embedding medium for quantitative morphologists.

Acrylic Resins↗

Does hard insertion and space improve shock absorption ability of mouthguard?

Mouthguards are expected to reduce sports-related orofacial injuries. Numerous studies have been conduced to improve the shock absorption ability of mouthguards using air cells, sorbothane, metal wire, or hard material insertion. Most of these were shown to be effective; however, the result of each study has not been applied to clinical use. The aim of this study was to develop mouthguards that have sufficient prevention ability and ease of clinical application with focus on a hard insertion and space. Ethylene vinyl acetate (EVA) mouthguard blank used was Drufosoft and the acrylic resin was Biolon (Dreve-Dentamid GMBH, Unna, Germany). Three types of mouthguard samples tested were constructed by means of a Dreve Drufomat (Type SO, Dreve-Dentamid) air pressure machine: the first was a conventional laminated type of EVA mouthguard material; the second was a three layer type with acrylic resin inner layer (hard-insertion); the third was the same as the second but with space that does not come into contact with tooth surfaces (hard + space). As a control, without any mouthguard condition (NOMG) was measured. A pendulum type impact testing machine with interchangeable impact object (steel ball and baseball) and dental study model (D17FE-NC.7PS, Nissin, Tokyo, Japan) with the strain gages (KFG-1-120-D171-11N30C2: Kyowa, Tokyo, Japan) applied to teeth and the accelerometer to the dentition (AS-A YG-2768 100G, Kyowa) were used to measure transmitted forces. Statistical analysis (anova, P < 0.01) showed significant differences among four conditions of NOMG and three different mouthguards in both objects and sensor. About acceleration: in a steel ball which was a harder impact object, shock absorption ability of about 40% was shown with conventional EVA and hard-insertion and about 50% with hard + space. In a baseball that was softer compared with steel ball, a decrease rate is smaller, reduction (EVA = approximately 4%, hard-insertion = approximately 12%, hard + space = approximately 25%) was admitted in the similar order. A significant difference was found with all the combinations except for between EVA and hard-insertion with steel ball (Tukey test). About distortion: both buccal and lingual, distortions had become small in order of EVA, hard-insertion, and hard + space, too. The decrease rate is larger than acceleration, EVA = approximately 47%, hard-insertion = 80% or more, and hard +space = approximately 98%, in steel ball. EVA = approximately 30%, hard-insertion = approximately 75%, and hard + space = approximately 98% in baseball. And a significant difference was found with all the combinations (Tukey test). Especially, hard + space has decreased the distortion of teeth up to several percentages. Acceleration of the maxilla and distortions of the tooth became significantly smaller when wearing any type of mouthguard, in both impact objects. But the effect of mouthguard was clearer in the distortion of the tooth and with steel ball. Considering the differences of mouthguards, the hard-insertion and the hard + space had significantly greater buffer capacity than conventional EVA. Furthermore, hard + space shows quite high shock absorption ability in the tooth distortion. Namely, hard + space has decreased the distortion of teeth up to several percentages in both impact objects.

Acceleration↗

Repair of a removable partial denture using gold occlusals.

Limited interarch space causes maintenance problems with removable partial dentures. The problem of abrasion and breakage of acrylic resin teeth, the concomitant supraeruption of opposing natural teeth, and possible decrease of vertical dimension of occlusion can be prevented or minimized with cast-gold occlusals. Use of metal occlusals has been advocated on newly constructed removable partial dentures, but not on existing prostheses with severely worn or broken denture teeth. This article describes a repair procedure for a removable partial denture where minimal interarch distance resulted in wear and breakage of denture teeth. A thin, abraded denture tooth that had been repaired numerous times was prepared and covered with a cast gold restoration. The problem of abrasion and breakage of the acrylic resin tooth was solved and the service life of the prosthesis was extended.

Acrylic Resins↗

A comparison of physical characteristics of six hard denture reline materials.

Six rigid autopolymerizing acrylic resins were examined to determine and compare the cost per reline, the curing temperatures, the setting times, and the porosity of each material. The cost per reline ranged from $0.63 to $1.55. Three product groups had significantly different mean setting times, and two groups had significantly different mean setting temperatures. SEM cross-sections of each product revealed an apparently porous-free solid mass of acrylic resin, which in two products was overlayed by a thin porous surface layer. The physical characteristics of any one product did not indicate clinical superiority.

Acrylic Resins↗

Microwave pressure chamber processing of a denture repair polymer.

Most denture base repairs are made using a chemically activated acrylic resin polymer for reasons of cost and expediency. Heat-activated polymers are not typically used because they require a custom split cast gypsum mold, longer polymerization time, and higher laboratory fees. Repairs made using a chemically activated polymer compared with a heat-activated polymer generally have reduced transverse strength, poorer color stability, increased water sorption, and weak bond strength to existing acrylic resin. A method of utilizing a microwave polymer in a commercially available microwave flask is described. This technique allows denture base repairs to be made with a heat-activated polymer in a manner similar to that of chemically activated repairs.

Acrylic Resins↗

Adherence of Candida albicans to glow-discharge modified acrylic denture base polymers.

An important aetiologic factor in the pathogenesis of denture-induced stomatitis, is the presence of numerous yeasts, usually Candida albicans, on the fitting surfaces of dentures. In the present study, effect of glow-discharge plasma, a technique applied to increase surface wettability of acrylic resins, on candidial adherence was evaluated. The durability of glow-discharge modification with saliva coating was also evaluated. Samples including control and experimental groups were prepared by using heat compression mould technique. To create a hydrophobicity gradient, experimental groups were exposed to a radiofrequency glow discharge in an O2 atmosphere under different discharge powers. To characterize the wetting properties, an expression of surface hydrophobicity, contact angle measurements were performed by the sessile drop method. The organism used was C. albicans (ATTC10321). Acrylic samples were coated with unstimulated whole saliva collected from a healthy man. The fungal suspension was poured on saliva-inoculated samples and incubated at 37 degrees for 2 h. The samples were then fixed with glutaraldehyde and Gram stained. Adhered candidial cells were examined by light microscope. Diffuse Reflectance FTIR (DRIFT) and scanning electron-microscope examinations were also performed to evaluate the surface composition and roughness of the test groups. Glow-discharge plasma was found to be an effective means of increasing surface wettability even with salivary pellicle. Amounts of candida cells adhered were significantly higher in all the plasma treated surfaces than the unmodified control group (P < 0.001). It was concluded that improving the surface wettability of acrylic resins by glow-discharge plasma in O2 atmosphere increased the adherence of the C. albicans.

Acrylic Resins↗

Effects of polishing techniques on the surface roughness of acrylic denture base resins.

STATEMENT OF PROBLEM: Rough surfaces of denture bases promote adhesion of microorganisms and plaque formation. It is therefore important to know how different polishing systems affect surface roughness of denture base acrylic resins. PURPOSE: The objective of this study was to compare the effects of 4 chairside polishing kits and 2 conventional laboratory techniques used for polishing 3 different acrylic denture base resins. MATERIAL AND METHODS: Using contact profilometric measurement, the surface texture of 54 specimens (15x30x3 mm) per acrylic material (autopolymerized ProBase Cold, heat-polymerized ProBase Hot, and injection heat-polymerized SR Ivocap plus) was studied before and after cutting with a tungsten carbide bur, and during and after chairside polishing with 4 polishing kits (Exa Technique, Acrylic Polisher HP blue, AcryPoint, Becht Polishing Cream), and after conventional polishing with 2 polishing systems (Universal Polishing Paste for Resins and Metals, Lesk Polishing Liquid). There were 9 specimens for each acrylic resin material and polishing method combination. Conventional lathe polishing with polishing paste served as the control. Mean average surface roughness (Ra) values of each specimen group were analyzed using a 2-way analysis of variance, the Scheffé post-hoc test, and paired t test (alpha=.05) with the Bonferroni adjustment. After testing the polished acrylic resin surfaces were evaluated under a scanning electron microscope. RESULTS: The highest mean average surface roughness (Ra=2.86+/-0.8 microm to 3.99+/-1.31 microm) was measured for surfaces finished with a tungsten carbide bur. The lowest surface roughness values (Ra=0.02+/-0.01 microm) were determined for acrylic resin specimens polished with a lathe and polishing paste. The Ra values of resin specimens after polishing with chairside silicone polishing kits ranged from 0.05+/-0.0 microm to 0.35+/-0.05 microm. Mean average Ra values of specimens polished with a polishing cream alone (Ra=1.01+/-0.17 microm to 1.68+/-0.47 microm) were significantly higher (P<.05) than those obtained with other polishing systems tested, which was confirmed by scanning electron microscope images of acrylic resin surfaces. Significant differences in mean average surface roughness were found between autopolymerizing and injected heat-polymerizing resin specimens. In addition, scanning electron microscopy revealed increased porosity of autopolymerizing resin specimens. CONCLUSIONS: Conventional laboratory polishing was found to produce the smoothest surface of denture base acrylic resin. Chairside silicone polishing kits produced a significantly smoother surface of acrylic resin than specimens polished with a tungsten carbide bur. The presence of large pores was characteristic for the autopolymerizing resin material.

Acrylic Resins↗

The stability of temporary prosthetic base materials. I: Introduction, angular changes and dimensional stability.

The bases of occlusal rims and trial dentures should fit both the cast and the mouth accurately. The retention of shape and dimension of strips and sheets of grey and pink shellac, filled cold cure acrylic resin and wax were tested following moulding over stylised upper edentulous casts. The thermoplastic materials were softened over a flame or in a water bath. Specimens were prepared with and without folding along the long axes of the strips. The angles formed by the strips, the gap between the palate of the baseplates and casts and the linear dimension of the sheets were measured after moulding, after immersion in water at 37 and 45 degrees C and after 24 h at room temperature. The least angular change was shown by unfolded grey shellac, softened over a flame and moulded by finger pressure over an unwarmed cast, followed by folded specimens softened in water and moulded with the fingers over a prewarmed cast. The least gap developed beneath pink shellac softened in water and moulded by finger pressure over a warmed cast. The smallest dimensional change was shown by grey shellac softened in water and moulded by finger pressure over a warmed cast. Thus, optimally manipulated shellac materials exhibit less change after moulding than cold cure acrylic resin or modelling wax.

Acrylic Resins↗

Adherence of phenotypically switched Candida albicans to denture base materials.

PURPOSE: The purpose of this study was to investigate in vitro the levels of adhesion of phenotypically switched and nonswitched Candida albicans to the smooth and rough surfaces of heat-cured acrylic resin, Molloplast B, and Novus. MATERIALS AND METHODS: Nonswitched and switched cells of C. albicans 3153A were prepared and adhesion assays were performed. RESULTS: There was no difference in the level of adhesion of blastospores in their nonswitched or switched state. The adherence of hyphae to all three denture base materials was statistically significantly increased when in a switched form. There was greater adhesion to the two soft lining materials than to the acrylic resin. CONCLUSIONS: Rough surfaces promote adhesion. There was no significant difference in the adhesion of switched and nonswitched blastospores, but there was increased adhesion of hyphal cells.

Acrylic Resins↗