Comparing MR image intensity standardization against tissue characterizability of magnetization transfer ratio imaging.

PURPOSE: To evaluate existing methods of standardization by exploiting the well-known tissue characterizing property of magnetization transfer ratio (MTR) values obtained from MT imaging, and compare the tissue characterizability of standardized T2, proton density (PD), and T1 images against the MTR images. MATERIALS AND METHODS: Image intensity standardization is a postprocessing method that was designed to correct for acquisition-to-acquisition signal intensity variations (nonstandardness) inherent in magnetic resonance (MR) images. The main idea of this technique is to deform the volume image histogram of each study to match a standard histogram, and to utilize the resulting transformations to map the image intensities into a standard scale. The method has been shown to produce a significant gain in similarity of resulting images and to achieve numeric tissue characterization. In this work we compared PD-, T2-, and T1-weighted images before and after standardization with the corresponding MT images for 10 patient MRI studies of the brain, in terms of the normalized median values on the corresponding image histograms. RESULTS: No statistically significant difference was observed between the standardized PD-, T2-, and T1-weighted images and the corresponding MTR images. However, a statistically significant difference was found between the pre- and poststandardized PD-, T2-, and T1-weighted images, and between the prestandardized PD-, T2-, and T1-weighted images and the corresponding MTR images. CONCLUSION: These results suggest that standardized T2, PD, and T1 images and their tissue-specific intensity signatures may be useful for characterizing disease.

Brain↗

Four-dimensional volume contrast ultrasound imaging of the gallbladder compared with tissue harmonic imaging: preliminary experience.

Comparison of volume contrast US imaging with tissue harmonic imaging for the evaluation of gallbladder lesions and determination of the adequate slice thickness in volume contrast US imaging were performed. Forty-one patients who had gallbladder lesions (polyps in 26, stones in 12, and sludge in 3) were enrolled in our study. A Voluson 730 Expert US scanner was used throughout. Volume contrast US imaging with slice thicknesses of 3, 5, 10 and 15 mm and tissue harmonic imaging of the gallbladder were obtained. Two abdominal radiologists reviewed the masked images and graded by consensus these images using a five-point scale [from grade 1, (best), to grade 5, (worst)], based on the sharpness of the anterior gallbladder wall, internal artifact, lesion conspicuity and acoustic shadowing from stone. Volume contrast US imaging with thin slice thicknesses (3 or 5 mm) was judged superior to both tissue harmonic imaging and with thick slice thicknesses (10 or 15 mm), with respect to the sharpness of the anterior wall and lesion conspicuity ( P<0.001). In terms of internal artifact, volume contrast imaging with thin slice thicknesses was significantly superior to both tissue harmonic imaging and volume contrast imaging with a 15 mm thickness ( P<0.001) and was judged to be marginally better than with a 10 mm thickness ( p>0.01). With regard to acoustic shadowing, volume contrast imaging with thin slice thicknesses was also significantly better than with thick slice thicknesses ( P<0.01), and it was also marginally better than tissue harmonic imaging ( P>0.01). Volume contrast US imaging with thin slice thicknesses provides a better image quality with fewer artifacts than three other types of images for the evaluation of gallbladder diseases.

Adult↗

Medical image retrieval based on plaque appearance and image registration.

The increasing amount of medical images produced and stored daily in hospitals needs a datrabase management system that organizes them in a meaningful way, without the necessity of time-consuming textual annotations for each image. One of the basic ways to organize medical images in taxonomies consists of clustering them depending of plaque appearance (for example, intravascular ultrasound images). Although lately, there has been a lot of research in the field of Content-Based Image Retrieval systems, mostly these systems are designed for dealing a wide range of images but not medical images. Medical image retrieval by content is still an emerging field, and few works are presented in spite of the obvious applications and the complexity of the images demanding research studies. In this chapter, we overview the work on medical image retrieval and present a general framework of medical image retrieval based on plaque appearance. We stress on two basic features of medical image retrieval based on plaque appearance: plaque medical images contain complex information requiring not only local and global descriptors but also context determined by image features and their spatial relations. Additionally, given that most objects in medical images usually have high intra- and inter-patient shape variance, retrieval based on plaque should be invariant to a family of transformations predetermined by the application domain. To illustrate the medical image retrieval based on plaque appearance, we consider a specific image modality: intravascular ultrasound images and present extensive results on the retrieval performance.

Humans↗

Impact of MR imaging on nationwide health care costs and comparison with other imaging procedures.

OBJECTIVE: We wished to determine the extent to which MR imaging contributes to the overall costs of imaging in the United States and to compare MR imaging costs with other imaging techniques. MATERIALS AND METHODS: All 23 current procedural terminology, version 4 (CPT-4) codes for MR imaging were extracted from the national 1993 Part B Medicare annual data reimbursement file. For each code, we calculated total Medicare physician reimbursements. Aggregate reimbursement for all MR imaging was compared with aggregate reimbursement for all 659 imaging-related current procedural terminology, version 4 codes and also with comparable figures for echocardiography and other categories of cardiovascular imaging. RESULTS: Within the 23 MR imaging codes, 1,449,911 examinations were performed on Medicare patients in 1993, for which physicians were reimbursed $370 million. Medicare reimbursement of physicians for all 659 imaging-related procedures was $5.3 billion. Thus, MR imaging accounted for only 7% of all imaging costs. By comparison, a group of just 10 imaging codes, which are primarily cardiovascular in nature, accounted for $1.67 billion, or 32% of the entire Part B costs for imaging. Reimbursements for echocardiography alone are more than twice those for MR imaging. CONCLUSION: From the national perspective, MR imaging does not appear to warrant its reputation as a costly procedure. The costs of echocardiography and other imaging related to the cardiovascular system are considerably higher.

Diagnostic Imaging↗

Inter-sequence and inter-imaging unit variability of diffusion tensor MR imaging histogram-derived metrics of the brain in healthy volunteers.

BACKGROUND AND PURPOSE: Diffusion tensor MR imaging has the potential to improve our ability to monitor several neurologic conditions. As a preliminary step to the assessment of the role of diffusion tensor MR imaging in the context of longitudinal and multicenter studies, we evaluated the effect of sequence-, imaging unit-, and imaging-reimaging-induced variations on diffusion tensor MR imaging quantities derived from histogram analysis of a large portion of the central brain of healthy volunteers. METHODS: Each of eight healthy volunteers underwent imaging on two MR imaging units using three different pulsed gradient spin-echo single shot echo-planar pulse sequences (each of them having a different diffusion gradient scheme). Four additional healthy participants underwent imaging twice on the same imaging unit to assess imaging-reimaging variability. RESULTS: For mean diffusivity histograms, the differences between inter-sequence and inter-imaging unit coefficients of variation were significant for all the considered quantities with P values ranging from.003 to <.001. Also, the inter-imaging unit coefficient of variation for average fractional anisotropy was significantly higher than the corresponding inter-sequence coefficient of variation (P =.002). In general, inter-sequence mean diffusivity histogram-derived metrics (coefficients of variation ranging from 1.72% to 5.56%) were more reproducible than were fractional anisotropy histogram-derived metrics (coefficients of variation ranging from 5.45% to 7.34%). Imaging-reimaging variability was found to fall in the range of inter-sequence coefficients of variation for all the considered quantities. CONCLUSION: This study shows that inter-sequence, imaging-reimaging, and inter-imaging unit variabilities of diffusion tensor MR imaging-derived measurements are relatively low, suggesting that diffusion tensor MR imaging might provide additional measures of outcome with which to assess the evolution of brain structural damage in large scale studies of various neurologic conditions.

Analysis of Variance↗

MRI quality control: six imagers studied using eleven unified image quality parameters.

Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation.

Algorithms↗

MR fluid-attenuated inversion recovery imaging as routine brain T2-weighted imaging.

We tried to investigate if magnetic resonance (MR) fluid-attenuated inversion recovery (FLAIR) imaging can be used as a routine brain screening examination instead of spin-echo T2-weighted imaging. Three hundred and ninety-four patients with clinically suspected brain diseases were randomly selected and examined with both brain MR FLAIR and T2-weighted imaging on the axial plane. These two imaging techniques were evaluated by two neuroradiologists as to which imaging was better for routine brain T2-weighted imaging. In 123 of 394 cases (31%), FLAIR imaging was superior to spin-echo T2-weighted imaging. Especially in cases with inflammatory diseases, traumatic diseases and demyelinating diseases, FLAIR imaging was particularly useful. Small lesions bordering cerebrospinal fluid (CSF) are often detected only by FLAIR imaging. In 259 cases (66%), including 147 normal cases (37%), they were equally evaluated. Only in 12 cases (3%) was conventional T2-weighted imaging superior to FLAIR imaging. Cerebrovascular lesions like cerebral aneurysm and Moyamoya disease could not be detected on FLAIR images because these structures were obscured by a low signal from the CSF. Also, because old infarctions tend to appear as low signal intensity on FLAIR images, the condition was sometimes hard to detect. Finally, FLAIR imaging could be used as routine brain T2-weighted imaging instead of conventional spin-echo T2-weighted imaging if these vascular lesions were watched.

Adolescent↗

Projected digital radiologic images for teaching: balance of image quality with data size constraints.

RATIONALE AND OBJECTIVES: The authors performed this study to determine, in the context of a teaching presentation with slides, the information content needed in a digitized radiologic image for it to be equivalent in quality to an analog image. MATERIALS AND METHODS: Eleven sets of radiologic images were obtained from a teaching file collection and digitized. The images were scanned at high resolution and saved as image files. The information content of each image was then halved repeatedly with repeat sampling of the image. This procedure was repeated nine times to yield a total of 10 images with an information content that ranged from very low (32 kB) to high (12 MB). Each of these image files was made into a 35-mm slide by using a digital slide maker. The original radiographs were subsequently made into slides by using conventional photographic methods. Care was taken to make the images identical in every respect except digitization and information content. The slides were shown to radiologists, who filled out questionnaires to rate image quality. RESULTS: Digitized slides that contain an average of 416 kB of data (the equivalent of a 750 x 570-pixel matrix with 8-bit gray levels) were equivalent to analog images for 90% of viewers. At 830 kB (1,060 x 800-pixel matrix with 8-bit gray levels), 100% of viewers found no difference between digitized and analog images. CONCLUSION: Digital images become indistinguishable from analog images if a sufficient amount of information is retained in the digital image. There is a defined relationship between the perception of quality and the information content of a digital image.

Image Processing, Computer-Assisted↗

Assessment of myocardial function with interactive non-breath-hold real-time MR imaging: comparison with echocardiography and breath-hold Cine MR imaging.

PURPOSE: To compare a spiral gradient-echo sequence with a radial steady-state free precession sequence and to compare these two interactive real-time cardiac magnetic resonance (MR) imaging examinations with harmonic two-dimensional echocardiography (ECHO) for the evaluation of regional myocardial function. MATERIALS AND METHODS: Electrocardiographically triggered breath-hold steady-state free precession (BH-SSFP) MR imaging was the reference standard. Thirty-five nonselected patients scheduled for routine ECHO were included. Data from corresponding two-, three-, and four-chamber long-axis views and a midventricular short-axis view were acquired with each modality. Image quality and depiction of segmental wall motion were scored semiquantitatively by using the 16-segment model of the American Society of Echocardiography. Repeated-measures analysis of variance was performed to assess differences in image quality and wall motion depiction scores among the four imaging methods. Agreement was assessed by using Cohen kappa statistics. RESULTS: Compared with the image quality achieved with BH-SSFP MR imaging, the image quality achieved with radial MR imaging was similar (nonsignificant difference), but that achieved with spiral MR imaging and ECHO was significantly inferior (P <.0001). There were no significant differences in the image quality of the long- and short-axis views between the radial and BH-SSFP sequences, while the image quality of the long-axis spiral (P <.05) and the short- and long-axis ECHO (P <.0001) views was lower than that of the BH-SSFP views. Compared with the mean wall motion score for BH-SSFP MR imaging, the mean wall motion score for radial MR imaging was not significantly different, but those for ECHO (P <.05) and spiral MR imaging (P =.0003) were significantly lower. Cohen kappa coefficients for agreement with the BH-SSFP sequence regarding wall motion scoring were 0.47 for ECHO, 0.67 for the spiral sequence, and 0.89 for the radial sequence. CONCLUSION: The radial sequence enables similar accurate assessment of regional wall motion compared with the BH-SSFP sequence and yields image quality that is superior to that yielded by the spiral sequence and ECHO.

Adult↗

Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging.

PURPOSE: To prospectively determine the accuracies of T2-weighted magnetic resonance (MR) imaging, dynamic contrast material-enhanced MR imaging, and quantitative three-dimensional (3D) proton MR spectroscopic imaging of the entire prostate for prostate cancer localization, with whole-mount histopathologic section findings as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was obtained from all patients. Thirty-four consecutive men with a mean age of 60 years and a mean prostate-specific antigen level of 8 ng/mL were examined. The median biopsy Gleason score was 6. T2-weighted MR imaging, dynamic contrast-enhanced MR imaging, and 3D MR spectroscopic imaging were performed, and on the basis of the image data, two readers with different levels of experience recorded the location of the suspicious peripheral zone and central gland tumor nodules on each of 14 standardized regions of interest (ROIs) in the prostate. The degree of diagnostic confidence for each ROI was recorded on a five-point scale. Localization accuracy and ROI-based receiver operating characteristic (ROC) curves were calculated. RESULTS: For both readers, areas under the ROC curve for T2-weighted MR, dynamic contrast-enhanced MR, and 3D MR spectroscopic imaging were 0.68, 0.91, and 0.80, respectively. Reader accuracy in tumor localization with dynamic contrast-enhanced imaging was significantly better than that with quantitative spectroscopic imaging (P < .01). Reader accuracy in tumor localization with both dynamic contrast-enhanced imaging and spectroscopic imaging was significantly better than that with T2-weighted imaging (P < .01). CONCLUSION: Compared with use of T2-weighted MR imaging, use of dynamic contrast-enhanced MR imaging and 3D MR spectroscopic imaging facilitated significantly improved accuracy in prostate cancer localization.

Aged↗

Serial isotropic three-dimensional fast FLAIR imaging: using image registration and subtraction to reveal active multiple sclerosis lesions.

OBJECTIVE: Image registration and subtraction to detect the change of disease burden in multiple sclerosis on serial MR images should benefit from the use of high-resolution isotropic voxels. We compared 1.2-mm isotropic three-dimensional (3D) fast fluid-attenuated inversion recovery (FLAIR) images with standard 3-mm two-dimensional spin-echo images for the detection of new or enlarging lesions in longitudinal studies. SUBJECTS AND METHODS: Serial MR images were obtained at baseline, month 6 (n = 20), and month 7 (n = 16). For the half-yearly intervals, subtracted 3D FLAIR images and T2-weighted spin-echo images were compared. For the monthly intervals, subtracted 3D FLAIR images were compared with triple-dose contrast-enhanced T1-weighted spin-echo images. New, enlarging, and enhancing lesions were marked in consensus by two radiologists. RESULTS: At the half-yearly intervals, 3D FLAIR imaging detected more new or enlarging lesions than T2-weighted spin-echo imaging, both at the initial interpretation (80 vs 52; p < 0.001) and after a side-by-side comparison of the lesions (88 vs 65; p < 0.001). Post hoc analyses showed the largest benefit for new (rather than enlarging), for small, and for temporal lesions. At the monthly intervals, 32 enhancing lesions were detected on contrast-enhanced T1-weighted spin-echo images versus 20 new or enlarging lesions detected on 3D FLAIR images (p < 0.05). After a side-by-side comparison of the lesions, seven additional lesions were identified on 3D FLAIR images, making the difference with contrast-enhanced T1-weighted spin-echo images insignificant (27 vs 32; p > 0.05). CONCLUSION: Isotropic 3D FLAIR imaging holds great promise for the detection of new or enlarging lesions in multiple sclerosis using registration and subtraction techniques certainly at longer intervals.

Adult↗

The electronic portal imaging system Siemens Beamview Plus versus the conventional verification films CEA-TVS and DuPont COL-7. A critical appraisal of visual image quality.

AIM: The aim of this study was the validation of the visual image quality of electronic portal imaging devices (EPID) and conventional verification films from the point of view of the end-viewers of portal films, the radiotherapists. MATERIAL AND METHODS: The verification image was represented in two different forms, viz. an electronic portal image employing Siemens Beamview Plus (on a computer monitor) and two different portal films using the conventional verification films CEA-TVS and DuPont CQL-7 (on a negatoscope). A total of 270 image sets (simulation film and portal image) were evaluated by each radiotherapist, evaluation extending to 90 sets of each type of verification film. Each set was evaluated by three specialists in radiotherapy examining subjective visual image quality whereby the following aspects served as evaluation criteria: contrast, artifacts, determination of actual radiation field edge position, anatomical structures and main structural feature for the determination of treatment field position. In addition, the anatomical structures employed for visual feature correlation between reference and portal films were classified according to their importance. RESULTS: In general the electronic portal image was rated significantly "visible" or better. Only the evaluation of artifacts showed an appreciable disadvantage for electronic portal imaging caused by physical artifacts due to radiographic technique and data processing aspects peculiar to the Siemens Beamview Plus 1.1. and also caused by different image processing tools reducing physical artifacts and enhancing the visibility of anatomical structures and likewise of anatomical artifacts (e.g. intestinal gas). By calculating the Spearman correlation coefficient to detect a possible relationship between the different criteria of subjective visual image quality, the research demonstrated that artifacts when limited to a tolerable proportion had no significant impact on the other criteria. CONCLUSIONS: As data of EPIDS are digital, images can be postprocessed and enhanced in a wide variety of ways. Using this tool the electronic portal imaging device provides images that, in terms of visual image quality, are at least comparable to the two evaluated types of radiographic films and also have the added advantage that such images are stored and can be transferred electronically being presupposition for digital patient documentation.

Artifacts↗

Narrow band deformable registration of prostate magnetic resonance imaging, magnetic resonance spectroscopic imaging, and computed tomography studies.

PURPOSE: Endorectal (ER) coil-based magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging (MRSI) is often used to obtain anatomic and metabolic images of the prostate and to accurately identify and assess the intraprostatic lesions. Recent advancements in high-field (3 Tesla or above) MR techniques affords significantly enhanced signal-to-noise ratio and makes it possible to obtain high-quality MRI data. In reality, the use of rigid or inflatable endorectal probes deforms the shape of the prostate gland, and the images so obtained are not directly usable in radiation therapy planning. The purpose of this work is to apply a narrow band deformable registration model to faithfully map the acquired information from the ER-based MRI/MRSI onto treatment planning computed tomography (CT) images. METHODS AND MATERIALS: A narrow band registration, which is a hybrid method combining the advantages of pixel-based and distance-based registration techniques, was used to directly register ER-based MRI/MRSI with CT. The normalized correlation between the two input images for registration was used as the metric, and the calculation was restricted to those points contained in the narrow bands around the user-delineated structures. The narrow band method is inherently efficient because of the use of a priori information of the meaningful contour data. The registration was performed in two steps. First, the two input images were grossly aligned using a rigid registration. The detailed mapping was then modeled by free form deformations based on B-spline. The limited memory Broyden-Fletcher-Goldfarb-Shanno algorithm (L-BFGS), which is known for its superior performance in dealing with high-dimensionality problems, was implemented to optimize the metric function. The convergence behavior of the algorithm was studied by self-registering an MR image with 100 randomly initiated relative positions. To evaluate the performance of the algorithm, an MR image was intentionally distorted, and an attempt was then made to register the distorted image with the original one. The ability of the algorithm to recover the original image was assessed using a checkerboard graph. The mapping of ER-based MRI onto treatment planning CT images was carried out for two clinical cases, and the performance of the registration was evaluated. RESULTS: A narrow band deformable image registration algorithm has been implemented for direct registration of ER-based prostate MRI/MRSI and CT studies. The convergence of the algorithm was confirmed by starting the registration experiment from more than 100 different initial conditions. It was shown that the technique can restore an MR image from intentionally introduced deformations with an accuracy of approximately 2 mm. Application of the technique to two clinical prostate MRI/CT registrations indicated that it is capable of producing clinically sensible mapping. The whole registration procedure for a complete three-dimensional study (containing 256 x 256 x 64 voxels) took less than 15 min on a standard personal computer, and the convergence was usually achieved in fewer than 100 iterations. CONCLUSIONS: A deformable image registration procedure suitable for mapping ER-based MRI data onto planning CT images was presented. Both hypothetical tests and patient studies have indicated that the registration is reliable and provides a valuable tool to integrate the ER-based MRI/MRSI information to guide prostate radiation therapy treatment.

Algorithms↗

Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology.

Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image transmission, most of which are included in a picture archiving and communication system (PACS). The content of this paper includes a short review of research and development in medical imaging science and technology, which covers (a) diagnostic imaging in the 1950s, (b) the importance of image quality and diagnostic performance, (c) MTF, Wiener spectrum, NEQ and DQE, (d) ROC analysis, (e) analogue imaging systems, (f) digital imaging systems, (g) image processing, (h) computer-aided diagnosis, (i) PACS, (j) 3D imaging and (k) future directions. Although some of the modalities are already very sophisticated, further improvements will be made in image quality for MRI, ultrasound and molecular imaging. The infrastructure of PACS is likely to be improved further in terms of its reliability, speed and capacity. However, CAD is currently still in its infancy, and is likely to be a subject of research for a long time.

Biological Science Disciplines↗

Prostate cancer: endorectal MR imaging and MR spectroscopic imaging--distinction of true-positive results from chance-detected lesions.

PURPOSE: To retrospectively investigate size criteria for the identification of chance-detected lesions at endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging of prostate cancer. MATERIALS AND METHODS: Approval of the committee on human research and written informed consent were obtained. This study was HIPAA compliant. Endorectal MR imaging and MR spectroscopic imaging were performed with a 1.5-T MR imager in 48 men with a mean age of 59 years (age range, 47-75 years) prior to radical prostatectomy. Two independent readers recorded the size and location of all suspected peripheral zone tumor nodules on MR images alone and on images obtained with combined MR imaging and MR spectroscopic imaging. Nodules detected at MR imaging were classified as matched lesions if tumor was present in the same location at step-section histopathologic review. For all matched lesions, kappa values were calculated to examine agreement between measured and actual tumor size. Lesions that were overmeasured at MR imaging with a kappa value of less than 0.2 were considered chance-detected lesions. RESULTS: At MR imaging, two of 27 and four of 35 matched lesions for readers 1 and 2, respectively, were chance-detected lesions. The corresponding numbers of lesions at combined MR imaging and MR spectroscopic imaging were one of 21 and one of 31, respectively. In all but two cases, the measured diameter of chance-detected lesions was more than twice that of the diameter at histopathologic analysis. By using this diameter threshold to distinguish true-positive results, the mean diameter of detected tumors at histopathologic analysis was 15 mm compared with 4 mm for both undetected and chance-detected tumors (P < .05). CONCLUSION: To ensure uniformity in the comparison of scientific studies, peripheral zone tumors detected at MR imaging and MR spectroscopic imaging of the prostate that are in the same location as tumors detected at histopathologic review should be considered chance-detected lesions if the MR transverse diameter is more than twice the histopathologic transverse diameter.

Aged↗

Differential uptake and apparent 201Tl washout after thallium reinjection. Options regarding early redistribution imaging before reinjection or late redistribution imaging after reinjection.

BACKGROUND: Because thallium reinjection enhances the identification of viable myocardium, many laboratories have adopted the routine practice of performing reinjection imaging instead of 3-4-hour redistribution imaging. This approach assumes that the stress-reinjection protocol provides the necessary information regarding both exercise-induced ischemia and myocardial viability. Because apparent "washout" of thallium may occur between redistribution and reinjection studies, we examined the limitations created by eliminating 3-4-hour redistribution images. METHODS AND RESULTS: We studied 50 patients with chronic stable coronary artery disease by exercise thallium tomography, radionuclide angiography, and coronary arteriography. Immediately after the 3-4-hour redistribution images, 1 mCi thallium was injected at rest, and images were reacquired both 10 minutes and 24 hours after reinjection. The stress, redistribution, reinjection, and 24-hour images were then analyzed quantitatively, and the magnitude of change in regional thallium activity after reinjection was termed "differential uptake." Of the 127 abnormal myocardial regions on the stress images, 55 (43%) demonstrated either complete or partial reversibility on 3-4-hour redistribution images. After reinjection, 14 of these regions (25%) demonstrated apparent thallium washout due to low differential uptake of thallium, which was only 46 +/- 20% of that observed in normal regions. As a result, the relative thallium activity, which was 55 +/- 13% during stress (relative to normal regions) and increased significantly to 75 +/- 13% on 3-4-hour redistribution studies (p less than 0.001), decreased to only 58 +/- 13% after thallium reinjection. At 24 hours, redistribution again developed in all 14 regions, resulting in a relative thallium activity of 71 +/- 16% (p less than 0.03), which was similar to that achieved on 3-4-hour redistribution images. Twelve of the 14 regions (86%) exhibiting apparent washout after reinjection were supplied by a totally occluded coronary artery, of which eight (67%) had normal wall motion at rest. In contrast, only 41% of the regions with either improved or unchanged thallium uptake after reinjection were supplied by a totally occluded coronary artery (p less than 0.05). CONCLUSIONS: These data indicate that regions with thallium defects that are reversible on 3-4-hour redistribution images may demonstrate apparent washout of thallium after reinjection due to low differential uptake. Although this occurs in only a small fraction of regions (8%) identified as abnormal on exercise images, these regions represent approximately 25% of regions showing redistribution. Such defects would appear irreversible if redistribution imaging is not performed before reinjection. However, these same myocardial regions also redistribute further after reinjection and are identified as reversible on 24-hour images. Thus, one of two imaging options, either stress-redistribution-reinjection imaging or stress-reinjection-24-hour imaging, may be used for a comprehensive assessment of myocardial ischemia and viability.

Coronary Angiography↗

Diffusion-weighted MR imaging offers no advantage over routine noncontrast MR imaging in the detection of vertebral metastases.

BACKGROUND AND PURPOSE: Diffusion-weighted MR imaging of the spine has been used to differentiate benign from pathologic vertebral body compression fractures. We sought to determine the utility of diffusion-weighted MR imaging in the detection of vertebral metastases and to compare it with conventional noncontrast T1- and T2-weighted MR imaging. METHODS: Fifteen patients with metastases to the spine were studied using conventional MR imaging and diffusion-weighted imaging. Blinded review of all images was undertaken, and patients were categorized according to whether they had focal or multiple lesions. The signal intensity of the lesions was compared on T1-, T2- (fast spin-echo), and diffusion-weighted images. RESULTS: In five patients with focal disease, metastases were hypointense on T1-weighted images; hypointense (n = 2), isointense (n = 1), or hyperintense (n = 2) on T2-weighted images; and hypointense (n = 3) or hyperintense (n = 2) on diffusion-weighted images with respect to presumed normal bone marrow. In 10 patients with disease in multiple sites, all lesions were hypointense on T1-weighted images; hypointense (n = 2), isointense (n = 4), hyperintense (n = 2), or mixed (n = 2) on T2-weighted images; and hypointense (n = 5), hyperintense (n = 3), or mixed (n = 2) on diffusion-weighted images with respect to presumed normal bone marrow. CONCLUSION: As used in this study, diffusion-weighted MR imaging of the spine showed no advantage in the detection and characterization of vertebral metastases as compared with noncontrast T1-weighted imaging, but was considered superior to T2-weighted imaging.

Adult↗

MR imaging of the breast. Imaging and tissue characterization without intravenous contrast.

The development of noninvasive techniques should always be an important goal of diagnostic radiology. Despite the recent excitement regarding intravenous MR imaging contrast agents (e.g., Gd-DTPA), the role of noncontrast MR imaging for the breast should not be overlooked. First, it must be kept in mind that administration of an intravenous contrast material is an invasive procedure that poses some health concern and may not be acceptable to certain patients. Second, injection of intravenous contrast media is an expensive procedure that incurs costs related to the contrast media itself as well as from the personnel required to administer the media and monitor any adverse reactions. Third, there may be specific imaging situations in which a lesion must be located prior to administration of contrast media, for example, when dynamic contrast enhanced imaging is to be performed and temporal resolution limits the volume of coverage to only a few slices. Finally, noncontrast MR imaging techniques also may be useful in their own right for obtaining information not otherwise available from a contrast-enhanced study, particularly quantitative relaxometric and spectroscopic measurements that may be useful for tissue characterization. It should also be noted that optimized noncontrast MR methods also might be used in conjunction with contrast agents to improve overall clinical utility. The heterogeneous nature of the breast and the overlap in T1 and T2 between different normal and abnormal breast tissue types frequently renders conventional noncontrast breast MR images confusing and ambiguous. Hybrid imaging approaches combining T1 weighting, T2 weighting, and fat suppression techniques as well as multivariate image analysis may be helpful for improving the sensitivity of MR imaging to breast disease; however, specificity remains a problem. Recent advances in clinical MR imaging have provided the opportunity to explore other approaches which may shed new light on the characterization of breast disease including NMRD, spin locking, magnetization transfer, and multicomponent relaxation analysis. MR imaging derived morphologic factors (i.e., lesion spiculation, parenchymal patterns) also may have a role to play in breast disease diagnosis and risk assessment. Several avenues of future development of noncontrast breast MR imaging would seem fruitful. NMRD and spin locking results suggest the potential contrast benefit of low field imaging of the breast, particularly, with the probable development of open concept low field MR imaging devices, which will provide improved access and low cost. In vivo relaxation time measurements, particularly multi-component T2 analysis and incorporation of MTC and chemical shift imaging techniques, may improve breast MR image specificity.(ABSTRACT TRUNCATED AT 400 WORDS)

Breast↗