Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamic range”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Location and functional organization of trigeminal wide dynamic range neurons within the nucleus ventralis posteromedialis of the cat.

In urethane-chloralose-anesthetized cats, trigeminal wide dynamic range (WDR) neurons were explored in the posterior thalamus. They were found within a narrow zone (about 300 micrometer wide) of the shell region of the nucleus ventralis posteromedialis (VPM), just rostral to the region where trigeminal nociceptive specific (NS) neurons were located. This narrow zone was somatotopically organized with respect to the center of the receptive field. The mandibular division was represented ventromedially, the ophthalmic division was represented dorsolaterally, and the maxillary division fell in between. Neither NS nor WDR trigeminal units were found within the medial part of the posterior complex of the thalamus (POm).

Animals↗

Intravenous midazolam suppresses noxiously evoked activity of spinal wide dynamic range neurons in cats.

The effects of intravenously (i.v.) administered midazolam on noxiously evoked activity of spinal wide dynamic range (WDR) neurons were investigated in decerebrate, spinal-cord-transected cats. Extracellular, single-unit recordings were measured during stimulation by pinching the receptive field on the hind paw and the effect of midazolam at doses of 0.25, 0.5, 1, 2, and 4 mg/kg were measured. Two series of experiments were performed to characterize the analgesic effects of midazolam. In the first, dose-response experiments (n = 59) demonstrated a dose-dependent suppression of the noxiously evoked activity of spinal WDR neurons after midazolam administration. This effect of midazolam was maximal at a dose of 1 mg/kg i.v.. The second series of experiments (n = 14) demonstrated that a benzodiazepine antagonist, flumazenil (n = 8), promptly reversed the effect of midazolam, while an opioid antagonist, naloxone (n = 6), had no effect on the effect of midazolam. The present study demonstrates that i.v. administered midazolam suppresses noxiously evoked activity of spinal WDR neurons that is reversible by a benzodiazepine antagonist. This is consistent with an analgesic action of midazolam.

Animals↗

[The measurement of the dynamic range of digital systems for visualizing x-ray images].

The paper presents a procedure to measure the dynamic range of digital X-ray image visualization systems, which is used for acceptance and certification tests of this class of equipment. The procedure is based on the use of experimental dependences of transmission of a narrow X-ray beam on the thickness of an aluminium or copper absorber (filter).

Filtration↗

Bi-directional flow sensor with a wide dynamic range for medical applications.

This paper describes a novel three-wire thermal flow sensor for medical applications. The present innovation for low-frequency measurements involves the use of a pulsed-wire anemometer with a comparatively large wire diameter (12.5 microm and larger) together with a novel signal processing approach. A small wire is heated using a sinusoidal alternating current, and two sensing wires, acting as resistance thermometers, are set parallel to, and at a small distance on either side of, the pulsed wire. The thermal wake of the pulsed wire is convected downstream to one of the two receiving wires which detect its delayed arrival. This arrangement allows the sensing of both the direction and the flow velocity component normal to the three probes. By appropriate signal processing, the present sensor can be operated such that the phase shift between the periodic current that drives the central wire and the detected signal by either the upstream or downstream wire takes into account a combination of convection, diffusion and the finite thermal response time of both the pulsed wire and the receiving wire. Because the time constants increase as the flow velocity decreases, the time lag due to thermal inertia supplements the time lag due to the true time of flight, thus yielding an effective operating range of 0.05 m/s <or= U <or= 25 m/s , which corresponds to a dynamic range of 500:1. This wide velocity range is an order of magnitude larger than that for the traditional time-of-flight pulsed-wire anemometers. An important application of the bi-directional thermal flowmeter is the measurement of human respiration, e.g. for early diagnostics of asthmatic attacks. The main advantage of the present sensor is its low sensitivity to variations in temperature and also to the composition of the flowing gas. Also, a calibration will be not needed for each density and gas used in addition to that for velocity. The resultant design work aimed at developing a sensor that can be mass-produced at low cost.

Asthma↗

Physiological characteristics of responses of wide dynamic range spinal neurones to cutaneously applied vibration in the cat.

Extracellular single-unit recordings were made from wide dynamic range neurones in the lumbar dorsal horn of anaesthetized or decerebrated cats. Vibration applied to the skin at a frequency of 80 Hz could evoke 3 distinct types of response--excitation, depression or a biphasic response consisting of excitation followed by depression. By applying vibration at different sites, a given neurone was found to show more than one type of response. Parametric studies of the depressant and biphasic responses were made because previous studies indicated that adenosine mediates the depression in these types of response. Thus, amplitude- and frequency-response relationships were determined at individual stimulation sites: amplitude was varied from 0.001 to 1.0 mm (frequency, 80 Hz) and the frequencies studied were 10, 20, 40, 80, 120 and 240 Hz (amplitude, 0.15 mm). Vibration at amplitudes greater than 0.15 mm caused a decrease in the rate of discharge during the period of stimulation, the magnitude of this decrease varying directly with amplitude; at amplitudes of 0.15 mm and less vibration had no statistically significant effect. With regard to the frequency-response relationship, a decrease in discharge rate occurred at frequencies of 120 and 240 Hz, with the more pronounced effect at 240 Hz; excitation occurred at 40 Hz and there was no statistically significant effect at other frequencies. Amplitude- and frequency-response relationships for the depressant and the biphasic responses were analyzed separately. In the case of depressant responses, the magnitude was monotonically related to the amplitude of stimulation and depression occurred only at frequencies of 80 Hz or greater, with higher frequencies being more effective. The biphasic responses appeared to consist of 2 subtypes termed biphasic-1 and biphasic-2 responses. For biphasic-1 responses, the amplitude- and frequency-response curves were similar to those of depressant responses. Biphasic-2 responses differed in that the response was biphasic when the stimulation frequency was 80 Hz or greater and the amplitude was 0.3 mm or more, yet, at lower frequencies and/or amplitudes vibration evoked excitation. The similarities in the amplitude- and frequency-response relationships of depressant and biphasic-1 responses raise the possibility that these responses might be mediated by a single class of primary afferent. Both depressant and biphasic responses were evoked when stimulation parameters (2 microns, 240 Hz) were used which selectively activate Pacinian corpuscle afferents. Depression with 240-Hz stimulation was attenuated by administration of caffeine (60 mg/kg i.v.) suggesting that the depressant and biphasic-1 responses may be mediated by afferents from Pacinian corpuscles.

Action Potentials↗

Accuracy and dynamic range of spatial image correlation and cross-correlation spectroscopy.

We present a comprehensive study of the accuracy and dynamic range of spatial image correlation spectroscopy (ICS) and image cross-correlation spectroscopy (ICCS). We use simulations to model laser scanning microscopy imaging of static subdiffraction limit fluorescent proteins or protein clusters in a cell membrane. The simulation programs allow us to control the spatial imaging sampling variables and the particle population densities and interactions and introduce and vary background and counting noise typical of what is encountered in digital optical microscopy. We systematically calculate how the accuracy of both image correlation methods depends on practical experimental collection parameters and characteristics of the sample. The results of this study provide a guide to appropriately plan spatial image correlation measurements on proteins in biological membranes in real cells. The data presented map regimes where the spatial ICS and ICCS provide accurate results as well as clearly showing the conditions where they systematically deviate from acceptable accuracy. Finally, we compare the simulated data with standard confocal microscopy using live CHO cells expressing the epidermal growth factor receptor fused with green fluorescent protein (GFP/EGFR) to obtain typical values for the experimental variables that were investigated in our study. We used our simulation results to estimate a relative precision of 20% for the ICS measured receptor density of 64 microm(-2) within a 121 x 98 pixel subregion of a single cell.

Algorithms↗

[Effects of halothane on spinal dorsal horn WDR(wide dynamic range) neuronal activity in cats].

The effects of halothane (0.2%, 0.5%, and 1.0%) on the spinal dorsal horn wide dynamic range (WDR) neuronal activity was studied in either spinal cord intact or spinal transected cats. Extracellular activity was recorded in the dorsal horn from single WDR neurons responding to noxious and non-noxious stimuli applied to the cutaneous receptive fields on the left hind foot pads of intact or decerebrate, spinal cord transected (L 1-2) cats. When 10 micrograms of bradykinin was injected into the femoral artery ipsilateral to the recording site as the noxious test stimulus in the spinal cat, all of 7 WDR neurons gave excitatory responses which were not depressed by 0.2% and 0.5% halothane but were depressed significantly by 1.0%. On the other hand, when the injection of 10 micrograms of bradykinin into the femoral artery ipsilateral to the recording site was used in the intact cat, 7 of 14 WDR neurons (50%) gave excitatory responses, which were not depressed by 0.2% halothane but were significantly depressed by 0.5% and 1.0% halothane, and 7 of 14 WDR neurons (50%) gave inhibitory responses, which were significantly depressed by 0.2%, 0.5%, and 1.0% halothane. We have found that halothane reduces the excitation as well as the inhibition of dorsal horn WDR neuronal activity induced by bradykinin injection.

Animals↗

[Dynamic range of acoustic reflex and its importance for hearing aid evaluation (author's transl)].

It is reported on the dynamic range of acoustic reflex in the case of normal hearing. Stimulation is carried out with speech noise under free field conditions. The sensitivity of impedance measurement is increased by using an averager, which enables acoustic reflex measurements at sound pressure levels of about 70 dB. Further an exact evaluation of input-output-characteristics becomes possible by this procedure. Basing on this consideration the possibility of objective hearing aid evaluation is discussed. The fundamental point of this technique should be the compensation of pathological input-output-characteristics by suitable hearing aids.

Ear, Middle↗

The subjective evaluation of the expansion time constant in single-channel wide dynamic range compression hearing instruments.

The present study investigated the subjective evaluation of expansion time constants in single-channel wide dynamic range compression (WDRC) hearing instruments. Thirty participants utilized binaural WDRC hearing instruments for a two-week trial. Subjective evaluations were conducted by having each participant rate their satisfaction with the expansion time constant on a daily basis and by having each participant indicate their preferred expansion time constant following the completion of the two-week trial. Each change in expansion time constant significantly affected listener satisfaction; however, all time constants resulted in satisfactory performance. Of the users expressing a preference, 75% preferred fast-acting over slow-acting expansion. These findings suggest that dynamic expansion parameters play an important role in determining the effectiveness of the feature for a given listener.

Adult↗

Hypersensitivity of dorsal horn wide dynamic range neurons to cutaneous mechanical stimuli after transient spinal cord ischemia in the rat.

The responsiveness of dorsal horn wide dynamic range (WDR) neurons to cutaneous mechanical stimuli was studied in decerebrate, spinalized, unanesthetized rats before and after transient photochemically induced spinal cord ischemia. In normal rats, the discharges of dorsal horn WDR neurons to the graded mechanical stimuli applied with calibrated von Frey hairs increase linearly. One to four days after spinal ischemia, when the rats exhibit a strong allodynia-like behavioral reaction to cutaneous stimuli, the sensitivity of dorsal horn WDR neurons to mechanical pressure is greatly increased. There is a significant decrease in the threshold pressure to evoke neuronal discharges and the exponential stimulus-response curve is shifted to the left. Thus, transient ischemia of the spinal cord results in hyperexcitability of dorsal horn WDR neurons, which may underly the allodynia-like sensory abnormalities observed in behaving animals. The present results may contribute to understanding the mechanism of the development of chronic central pain in patients after central nervous system injury involving ischemia.

Animals↗

The effect of galanin on wide-dynamic range neuron activity in the spinal dorsal horn of rats.

The present study investigated the effect of galanin on wide-dynamic range (WDR) neuron activity in the dorsal horn of the spinal cord of rats. The evoked discharge of WDR neurons was elicited by transdermic electrical stimulation applied on the ipsilateral hindpaw of rats. Galanin was administered directly on the spinal dorsal surface of L3-L5. The evoked discharge frequency of the WDR neurons decreased significantly after the administration of galanin and the effect lasted for more than 30 min. Furthermore, the inhibitory effect of galanin on the evoked discharge frequency of WDR neurons was blocked by following administration of the galanin antagonist galantide, indicating that the inhibitory effect of galanin on the activity of WDR neurons was induced by activating galanin receptors in the dorsal horn of the spinal cord. The results suggest that galanin has an inhibitory role in the transmission of presumed nociceptive information in the dorsal horn of the spinal cord in rats.

Animals↗

The effect of static stretch and dynamic range of motion training on the flexibility of the hamstring muscles.

To date, limited information exists describing a relatively new stretching technique, dynamic range of motion (DROM). The purpose of this study was to compare the effects of DROM with static stretch on hamstring flexibility. Fifty-eight subjects, ranging in age from 21 to 41 years and with limited hamstring flexibility (defined as 30 degrees loss of knee extension measured with the femur held at 90 degrees of hip flexion), were randomly assigned to one of three groups. One group performed DROM 5 days a week by lying supine with the hip held in 90 degrees of flexion. The subject then actively moved the leg into knee extension (5 seconds), held the leg in end range knee extension for 5 seconds, and then slowly lowered the leg to the initial position (5 seconds). These movements were performed six times per session (30 seconds of total actual stretching time). The second group performed one 30-second static stretch, 5 days per week. The third group served as a control group and did not stretch. Before and after 6 weeks of training, flexibility of the hamstring muscles was determined in all three groups by measuring knee extension range of motion (ROM) with the femur maintained in 90 degrees of hip flexion. Data were analyzed with a 2 x 3 (test x group) two-way analysis of variance (ANOVA) with repeated measures on one variable (test) and appropriate post hoc analyses. The results of the two-way ANOVA revealed a significant interaction. Further statistical post hoc analysis of data to interpret the interaction revealed significant differences between the control group (gain = 0.70 degree) and both stretching groups, as well as a significant difference between the static stretch group (gain = 11.42 degrees) and the DROM group (gain = 4.26 degrees). The results of this study suggest that, although both static stretch and DROM will increase hamstring flexibility, a 30-second static stretch was more effective than the newer technique, DROM, for enhancing flexibility. Given the fact that a 30-second static stretch increased ROM more than two times that of DROM, the use of DROM to increase flexibility of muscle must be questioned.

Adult↗

New speech tests reveal benefit of wide-dynamic-range, fast-acting compression for consonant discrimination in children with moderate-to-profound hearing loss.

Fast-acting, wide-dynamic-range compression (WDRC) has been shown to give better discrimination of soft speech and shouted speech than linear amplification for moderately hearing-impaired young adults. For severe and profound hearing losses, higher compression ratios are needed. The resultant distortion of the temporal envelope and reduced modulation depth may offset improvements in audibility offered by WDRC. This study compares the effectiveness of WDRC and linear amplification for children with different degrees of hearing loss. Pre-recorded tests of closed-set consonant confusions and open-set word recognition were developed to assess performance. Three groups of subjects (aged 4-14 years) with moderate (51-70 dB), severe (71-90 dB) and profound (91-115 dB) hearing loss were fitted with hearing aids programmed with WDRC or linear amplification. The frequency response was adjusted to match each child's own hearing aid prescription. For each group, stimuli were presented both in quiet and in noise at levels chosen to avoid floor and ceiling effects. Consonant confusion scores for the profound and severe groups combined and for the moderate group were significantly better with WDRC than with linear amplification. Open-set test results showed greater variability. Although mean scores were higher for WDRC than for linear processing, the effects were of marginal statistical significance.

Adolescent↗

Intrathecal clonidine suppresses noxiously evoked activity of spinal wide dynamic range neurons in cats.

The analgesic effectiveness of perispinal clonidine administration prompted us to evaluate clonidine effects on spinal dorsal horn wide dynamic range neurons. Intrathecal clonidine produced a dose-dependent (10 and 30 micrograms), yohimbine-reversible suppression of noxiously evoked activity in decerebrate, spinal cord-transected cats. In addition, combining ineffective intrathecal doses of morphine (25 micrograms) and clonidine (5 micrograms) produced statistically significant, reversible suppression of noxiously evoked activity. The time course of suppression was similar to that observed behaviorally. These results support the role of spinal alpha 2-adrenergic receptors in clonidine analgesia.

Analgesics↗

Identification of afferents contributing to sympathetically evoked activity in wide-dynamic-range neurons.

The purpose of this study was to determine which types of mechanoreceptor afferents contribute to sympathetically evoked activity in wide-dynamic-range (WDR) neurons--the spinal neurons thought to mediate sympathetically maintained pain. The experimental approach was to record and compare activity evoked in single WDR neurons, hair afferents, and slowly adapting type I (SAI) afferents in anesthetized cats. During electrical stimulation of the sympathetic trunk, WDR neurons responded with either an early transient burst of activity, sustained activity, or both. The early transient response was observed only in neurons with piloerection in the receptive field; this response had a similar time course to sympathetically evoked activity in hair afferents with piloerection in the receptive field. The sustained response that occurred in some WDR neurons was independent of piloerection and was similar in time course to the response evoked in SAI afferents by sympathetic stimulation. We conclude that hair and SAI afferents contribute to different components of sympathetically evoked activity in WDR neurons and that both types of afferents are likely to be involved in sympathetically maintained pain in humans.

Adrenergic Fibers↗

Altered discharges of spinal wide dynamic range neurons and down-regulation of glutamate transporter expression in rats with paclitaxel-induced hyperalgesia.

Changes in the signaling of wide dynamic range neurons and the expression of glutamate transporters in the lumbar spinal dorsal horn of rats with Taxol-induced hyperalgesia are detailed in this report. Deep spinal lamina neurons have significantly increased spontaneous activity and after-discharges to noxious mechanical stimuli, increased responses to both skin heating and cooling, and increased after-discharges and abnormal windup to transcutaneous electrical stimuli. The expression of glutamate transporter proteins in the dorsal horn is decreased at the time point corresponding to the physiological changes. These results suggest a state of increased excitability develops in spinal pain-signaling neurons as a consequence of decreased glutamate clearance. These changes in dorsal horn neurobiology likely in turn contribute to the hyper-responsiveness to sensory stimuli seen in animals treated with Taxol and may play a role in the pain seen in cancer patients receiving Taxol.

Amino Acid Transport System X-AG↗

Prediction of dynamic range from stapedius reflex in cochlear implant patients.

Amplitude growth functions of the electrically elicited stapedius reflex were compared with behavioral estimates of dynamic range in seven patients using multielectrode cochlear implants. The range between threshold and saturation level of the amplitude growth function usually either encompassed or fell between the preferred and uncomfortable listening levels. Implications of these findings for the initial mapping of electrodes in young children are discussed.

Adult↗

Optimizing dynamic range in children using the nucleus cochlear implant.

OBJECTIVE: The aim of this study was to investigate the benefits of the preprocessing scheme "Adaptive Dynamic Range Optimization" (ADRO) in children using Nucleus cochlear implants. Previous research with adults indicates improved speech perception in quiet and improved sound quality in everyday listening environments with the ADRO scheme. DESIGN: Children were given 4 wk of take-home experience with ADRO, with a minimum of 2 wk in which ADRO was "locked-in." After 1 wk of ADRO use and again after 4 wk of ADRO use, Bench-Kowal-Bamford (BKB) sentence perception in quiet at a low input level of 50 dB SPL (unweighted root mean square) and sentence perception in noise were compared with the child's everyday (Standard) program and the ADRO program. Children also rated the loudness of a variety of environmental sounds and indicated which program provided the best hearing in a variety of everyday listening situations. RESULTS: On average, BKB sentence perception in quiet at 50 dB SPL was significantly better with the ADRO program compared with the Standard program. The group mean improvement was 8.60%. Similarly, group mean scores for BKB sentences presented at 65 dB SPL in multitalker babble were significantly higher with the ADRO program (an improvement of 6.87%). The ADRO program was the preferred program in 46% of the listening situations, whereas the Standard program was preferred in 26% of situations. Everyday sounds were not unacceptably loud with ADRO. CONCLUSIONS: There was an ADRO benefit for this group of children in quiet and in noise. These findings suggest that young children would benefit from the ADRO programming option being locked in along with other processor settings in the SPrint processor once their MAP levels have stabilized. Some older children and teenagers may choose to use ADRO selectively for specific listening situations.

Acoustic Stimulation↗