Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “corrective measures”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Preliminary report: prescription of prism-glasses by the Measurement and Correction Method of H.-J. Haase or by conventional orthoptic examination: a multicenter, randomized, double-blind, cross-over study.

In a multicenter, randomized, double-blind, cross-over study in the Netherlands, the effectiveness of (prism-)glasses prescribed by the Measurement and Correction Method of H.-J. Haase (MKH) was compared to that of glasses prescribed by conventional orthoptic examination. Nine pairs of MKH-optometrists and orthoptists recruited patients who primarily presented with asthenopia, and each prescribed the patient (prism-)glasses. A questionnaire for asthenopia was developed that rated headache and tired eyes as 0-7 days per week and none-light-medium-severe, respectively. Light sensitivity, problems with focusing, near-work problems and burning eyes were each rated as: never-occasionally-often-always. A patient was eligible if he scored 'medium', 'often' or '5 days a week' twice; or 'medium' (etc.) once and 'light' (etc.) twice. Controls, in contrast to the patients, typically answered 'none' or 'never' to half of the complaints, but 37% of them would have passed the admission criteria. Among other criteria were: 18 to 40 years of age, horizontal angle < 4 degrees, vertical < 1.7 degrees, acuity > or = 0.8, stereopsis threshold disparity < 120". Seventy-two patients fulfilled all criteria and returned sufficient questionnaires. They wore the first glasses for six weeks, were without glasses for two weeks, and then wore the second glasses for six weeks. At the start, halfway and at the end of each 6-week period, questionnaires were filled out; 97% were returned. Only 19 of the orthoptists' glasses contained prisms (14 horizontal, 5 vertical; horizontal average of all glasses 0.49 PD, vertical 0.05 PD). Five of the orthoptists' glasses were plano. All MKH glasses contained prisms, 53 of 72 both horizontal and vertical, 18 only horizontal and one only vertical (horizontal average of all glasses 2.83 PD, vertical 0.79 PD). The starting levels of complaints were high and both glasses improved complaints dramatically. The starting levels were lower, but not significantly, in the second 6-week period and improvement was less outspoken. Because of these differences, the two periods had to be evaluated separately. The primary outcome of the study was defined as the difference between the effect of the MKH glasses and that of the orthoptists' glasses in the first and second 6-week periods. For problems with focusing, in the first 6-week period, and for tired eyes, in the second 6-week period, the difference exceeded the difference that had been defined as clinically significant (one day per week less headache or half the distance light-medium or half the distance occasionally-often), but it did not reach statistical significance. The statistical power was approximately 0.7 for demonstrating this clinically significant difference. Statistical significance was not reached in multivariate repeated measure ANOVA either. Forty-four patients preferred to keep the MKH glasses, 25 the orthoptists' glasses, including one plano. It is striking that 25% of the patients did not prefer the glasses that, according to the questionnaire, improved their complaints the most. A year after the study, the questionnaire was sent again to all patients: The levels of complaints after a year were similar to those at the end of the second 6-week period, whether they had preferred the MKH or the orthoptists' glasses, and were similar to the levels in controls. The most conspicuous finding was that both glasses improved the complaints dramatically. Apart from the prisms, other reasons could be: spherical and cylindrical correction, improved wearing comfort of the frame, placebo effect, Hawthorne effect and regression to the mean.

Adolescent↗

Measurement and correction of transmitter and receiver induced nonuniformities in vivo.

Signal intensity nonuniformities in high field MR imaging limit the ability of MRI to provide quantitative information and can negatively impact diagnostic scan quality. In this paper, a simple method is described for correcting these effects based on in vivo measurement of the transmission field B1+ and reception sensitivity maps. These maps can be obtained in vivo with either gradient echo (GE) or spin echo (SE) imaging sequences, but the SE approach exhibits an advantage over the GE approach for correcting images over a range of flip angles. In a uniform phantom, this approach reduced the ratio of the signal SD to its mean from around 30% before correction to approximately 6% for the SE approach and 9% for the GE approach after correction. The application of the SE approach for correcting intensity nonuniformities is demonstrated in vivo with human brain images obtained using a conventional spin echo sequence at 3.0 T. Furthermore, it is also shown that this in vivo B1+ and reception sensitivity mapping can be performed using segmented echo planar imaging sequences providing acquisition times of less than 2 min. Although the correction presented here is demonstrated with a simultaneous transmit and receive volume coil, it can be extended to the case of separate transmission and reception coils, including surface and phase array coils.

Algorithms↗

Correlation of volumetric magnetization transfer imaging with clinical data in MS.

We examined the relations between quantitative volumetric estimates of cerebral lesion load based on magnetization transfer imaging (MTI), clinical data, and measures of neuropsychological function in 44 patients with clinically diagnosed MS. In this population we assessed the correlation between several volumetric MTI measures, measures of neurologic function (Kurtzke Expanded Disability Status Scale and Ambulation Index), and disease duration using Spearman's correlation coefficient. Patients were classified on the basis of neuropsychological test performance as severely impaired, moderately impaired, and normal. We assessed differences between these groups with respect to MTI results using the Kruskal-Wallis test. MTI measures corrected for brain volume were found to correlate with disease duration (p < 0.01) and showed suggestive correlations with measures of neurologic impairment (p < 0.05). Individual neuropsychological tests correlated with MTI measures corrected and not corrected for brain volume (p < 0.001). An MTI measure not corrected for brain volume differed (p < 0.05) between severely impaired, moderately impaired, and normal patients. These preliminary results suggest that volumetric MTI analysis provides new measures that reflect more accurately the global lesion load in the brain of MS patients, and they may serve as a method to study the natural course of the disease and as an outcome measure to evaluate the effect of drugs.

Adult↗

The Youden Index and the optimal cut-point corrected for measurement error.

Random measurement error can attenuate a biomarker's ability to discriminate between diseased and non-diseased populations. A global measure of biomarker effectiveness is the Youden index, the maximum difference between sensitivity, the probability of correctly classifying diseased individuals, and 1-specificity, the probability of incorrectly classifying health individuals. We present an approach for estimating the Youden index and associated optimal cut-point for a normally distributed biomarker that corrects for normally distributed random measurement error. We also provide confidence intervals for these corrected estimates using the delta method and coverage probability through simulation over a variety of situations. Applying these techniques to the biomarker thiobarbituric acid reaction substance (TBARS), a measure of sub-products of lipid peroxidation that has been proposed as a discriminating measurement for cardiovascular disease, yields a 50% increase in diagnostic effectiveness at the optimal cut-point. This result may lead to biomarkers that were once naively considered ineffective becoming useful diagnostic devices.

Biomarkers↗

Paradoxical sensation of nasal airflow in patients with common cold. Are we measuring the correct modality?

CONCLUSIONS: A paradoxical relationship between objective and subjective measures of nasal obstruction exists in participants not exposed to any treatment. The sensation of nasal obstruction may be due to the amalgamation of many different nasal sensations. Improved methods for measuring nasal sensations are required to further investigate the relationship between objective and subjective measures of nasal obstruction. OBJECTIVES: In a recent study it was shown that the subjective sensation of nasal patency increased as the nasal passages became objectively more obstructed in patients who received a placebo compared to those who received an oral decongestant. This paradoxical response may be explained as a placebo effect, i.e. patients who received a placebo may have expected to feel less obstructed. The aim of the present study was to investigate this interesting paradox by determining objective and subjective measures of nasal obstruction over time in participants not exposed to any treatment. MATERIAL AND METHODS: A total of 60 healthy participants with common cold were recruited. Objective and subjective measures of nasal obstruction were recorded at baseline and at 1 and 2 h using posterior rhinomanometry and a visual analogue scale. RESULTS: Objective measures demonstrated an increase in nasal obstruction over time for both nasal passages considered together and for individual nasal passages. Subjective measures demonstrated a sensation of decreased nasal obstruction over time for both nasal passages considered together and for individual nasal passages.

Adult↗

Measured attenuation correction using the Maximum Likelihood algorithm.

Quantitative determination of local radioactivity concentration in positron emission tomography (PET) requires a good attenuation correction procedure to reconstruct the emission image. Using a similar Maximum Likelihood (ML) algorithm as for the reconstruction of the emission image, a method is proposed to reconstruct a transmission image, i.e. a map of absorption coefficients. This reconstructed transmission image is then used to calculate the attenuation correction factors needed for the ML reconstruction of the emission image. This approach takes automatically into account the convolution step in the acquisition process (caused by various smoothing factors, e.g. the detector width). This results in appreciable noise suppression without loss of resolution due to filtering, thus making the reconstructed images easier to interpret. A comparison is made with other estimates for the measured attenuation correction using phantom studies.

Algorithms↗

Correct height measurement in noncontact atomic force microscopy.

We demonstrate that topography measurements by noncontact atomic force microscopy are subject to residual electrostatic forces. On highly oriented pyrolitic graphite (HOPG) with a submonolayer coverage of C60, we monitor the step height from C60 to HOPG as a function of dc bias between tip and sample. Because of the different contact potential of C60 and HOPG ( approximately 50 mV), the step height is strongly dependent on the dc bias. The presented results and additional simulations demonstrate clearly that for correct height measurements it is mandatory to use a Kelvin probe force microscopy method with active compensation of electrostatic forces.

Graphite↗

Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction.

BACKGROUND: Blood glucose meters are widely used in point of care testing, however, many studies have shown inaccuracies in the glucose measurement due to a number of factors. The present study evaluated the accuracy of a new glucometer capable of simultaneous measurement of patient's hematocrit with algorithmic adjustment of glucose result. This meter was compared with a reference method and 2 other existing meters widely used in the market. METHODS: Venous whole blood samples from healthy volunteers were pooled and reconstituted to produce 5 different hematocrit (30-60%) concentrations. Each hematocrit specimen was spiked to produce 4 different glucose (50-500 mg/dl) concentrations. RESULTS: Hematocrit measured by the new meter correlated well with the reference method. Mean percentage error differences, compared to the reference method, showed obvious differences between existing meters across the wide hematocrit range at various glucose concentrations. The new meter showed a steady and consistent glucose concentrations compared to the reference method. CONCLUSION: The new glucometer, which simultaneously measures hematocrit and performs automated correction for the hematocrit effect, provides a glucose result with improved accuracy. Its measurement of hematocrit from the same blood sample will eliminate the need for additional collection of blood or measurement using another method.

Blood Glucose↗

[Effect of motion correction associated with echo train length and number of blades in propeller MRI-computer simulation].

The PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) MRI method is available with a technique for motion correction. We studied changes in correction according to differences in echo train length (ETL) and number of blades, and measured correction accuracy according to linear translation and rotation, using computer simulation. A T(2)-weighted axial image of the head taken by FSE was utilized as the basic MR image. We reconstructed other images with differences in quantity of motion, ETL, and number of blades, also using computer simulation. After motion correction was performed, we measured correction accuracy with cross-correlation to the basic image. The method of motion correction was performed by the conversion of k-space data for each blade step using 2D Fourier-transform. After motion correction of the obtained image had been carried out, the image was converted to k-space data using reverse Fourier-transform. For data of 30 pixels with horizontal translation, cross-correlation coefficients for the stationary image were 0.6 for FSE without motion correction, 0.74 for the PROPELLER (ETL 8, blades 32) image without motion correction, and 0.99 for the PROPELLER (ETL 8, blades 32) image with motion correction. For data of 24 degrees with rotation, cross-correlation coefficients were 0.38 for FSE without motion correction, 0.53 for the PROPELLER (ETL 8, blades 32) image without motion correction, and 0.93 for the PROPELLER (ETL 8, blades 32) image with motion correction. The cross-correlation coefficient of liner translation is higher than its rotation. Correction accuracy was better with larger numbers of ETL than without motion correction. The spatial resolution of the image was decreased in the corrected image more by rotation than linear translation. This study indicated that the PR method was able to inspect the imaging technique with little influence on movement.

Computer Simulation↗

A videofluoroscopy method for optical distortion correction and measurement of knee-joint kinematics.

Image distortion in video and image intensifier X-ray systems requires appropriate distortion correction methods to obtain accurate biomechanical quantitative measurements for joint kinematics applications. This paper presents an algorithm for coordinate reconstruction and distortion correction using a modified polynomial method. This algorithm was used for the measurement of patellar tendon moment arm, tibial plateau-tibial axis angle and patellar tendon-tibial axis angle during knee extension using videofluoroscopy in vivo. These parameters allow the determination of a two-dimensional biomechanical model of the knee for the measurement of muscle and joint forces during dynamic activities. Five males without knee joint injury history participated in the study. The mean measurement error obtained using an image intensifier-video system was 0.246 +/- 0.111 mm over a 180-mm x 180-mm field of view. The mean maximum patellar tendon moment arm was 39.87 mm at 44.9 degrees of knee flexion. The patellar tendon-tibial plateau angle was 112.9 degrees at full extension and decreased linearly to 87.6 degrees at 90 degrees of knee flexion. The mean angle between the tibial plateau and the tibial long axis was 84.8 degrees. Applications of the method include motion analysis using video and X-ray fluoroscopy systems with non-linear distortion problems. RELEVANCE: Accurate measurement of anatomical parameters from videofluoroscopy systems is important for the determination of joint biomechanical models and measurement of muscular and joint forces.

Journal Article↗

Correcting for measurement error in individual-level covariates in nonlinear mixed effects models.

The nonlinear mixed effects model is used to represent data in pharmacokinetics, viral dynamics, and other areas where an objective is to elucidate associations among individual-specific model parameters and covariates; however, covariates may be measured with error. For additive measurement error, we show substitution of mismeasured covariates for true covariates may lead to biased estimators for fixed effects and random effects covariance parameters, while regression calibration may eliminate bias in fixed effects but fail to correct that in covariance parameters. We develop methods to take account of measurement error that correct this bias and may be implemented with standard software, and we demonstrate their utility via simulation and application to data from a study of HIV dynamics.

Biometry↗

Measured inhomogeneity correction factors for lung in electron beam treatments of the chest wall.

A set of clinically relevant measurements of percentage depth dose and inhomogeneity correction factors for electron beam irradiation of the chest wall and underlying lung is given. Electron beam nominal energies of 9, 12, 15, and 18 MeV and lung densities of 0.22 g/cm3 and 0.404 g/cm3 are considered. This data can serve in treatment planning to indicate the penetration of the beam into the lung and serve as a comparison for calculation algorithms which are used to calculate electron dose absorption in heterogeneous phantoms.

Algorithms↗

A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging.

A phantom that can be used for mapping geometric distortion in magnetic resonance imaging (MRI) is described. This phantom provides an array of densely distributed control points in three-dimensional (3D) space. These points form the basis of a comprehensive measurement method to correct for geometric distortion in MR images arising principally from gradient field non-linearity and magnet field inhomogeneity. The phantom was designed based on the concept that a point in space can be defined using three orthogonal planes. This novel design approach allows for as many control points as desired. Employing this novel design, a highly accurate method has been developed that enables the positions of the control points to be measured to sub-voxel accuracy. The phantom described in this paper was constructed to fit into a body coil of a MRI scanner, (external dimensions of the phantom were: 310 mm x 310 mm x 310 mm), and it contained 10,830 control points. With this phantom, the mean errors in the measured coordinates of the control points were on the order of 0.1 mm or less, which were less than one tenth of the voxel's dimensions of the phantom image. The calculated three-dimensional distortion map, i.e., the differences between the image positions and true positions of the control points, can then be used to compensate for geometric distortion for a full image restoration. It is anticipated that this novel method will have an impact on the applicability of MRI in both clinical and research settings, especially in areas where geometric accuracy is highly required, such as in MR neuro-imaging.

Humans↗

Clinical observation units help manage costs and care.

Clinical observation units were created to avoid questionable admissions and short inpatient stays that were likely to result in Medicare payment denials. With the rise of managed care, these units also can contribute to ensuring optimal reimbursement by helping manage patient flow. Hermann Hospital, a facility affiliated with the University of Texas, Houston, initially opened an improved observation unit in 1992, but recorded a 13 percent Medicare payment denial rate and operating losses of as much as $20,000 per month during the first five months of the unit's operation. A multidisciplinary team was formed to address the observation unit's low utilization and payment denial problems. The problems identified included missed opportunities for admissions, inappropriate admissions, and extended stays. The facility took corrective measures based on the quality team's assessment and corrective measures developed by the utilization management committee and quality teams. The clinical observation unit now sustains a zero denial rate and steady revenue increases resulting from improved utilization of the unit.

Cost Savings↗

[Evaluation and improvement of the design of clinical records].

OBJECTIVE: To determine whether applying the methodology of Evaluation and care quality improvement to the design of Clinical Procedures can obtain Procedure documents of high scientific-technical quality, from the structural point of view. DESIGN: A retrospective evaluation study lasting 3 years. SETTING: The Barrio del Carmen Health Centre in Murcia. PATIENTS AND OTHER PARTICIPANTS: The Primary Care team. All those professionals with activities involving Procedure documents. INTERVENTIONS: The object of study is all the documentation of the Procedures produced between 1985 and 1993. The initial evaluation was in 1990. After the detection of deficiencies, corrective measures were proposed. In 1993 there was a re-evaluation, using the compliance scales of the quality of design criteria, which had been previously worked out on the basis both of the most important parts of the Bibliography and the quality specifications stated by the system's internal clients (the professionals). Measurements were made before and after intervention. MEASUREMENTS AND MAIN RESULTS: After the application of the corrective measures arising from the first evaluation, a significant improvement in all the design criteria for the procedures was obtained: the average defects per procedure document fell from 8.26 to 1.85. Three of the procedure documents ended up having no defects, either in structure or formal design (format, design method and document production). CONCLUSIONS: A substantial improvement in the structural quality of the documents for the Procedures developed in our Health Centre was achieved by applying the methodology of evaluation and quality improvement.

Algorithms↗

A comparison of response time and word recognition measures using a word-monitoring and closed-set identification task.

OBJECTIVES: The primary purpose of this study was to investigate the possibility of improving speech recognition testing sensitivity by incorporating response time measures as a metric. Two different techniques for obtaining response time were compared: a word-monitoring task and a closed-set identification task. DESIGN: Recordings of the Modified Rhyme Test were used to test 12 listeners with normal hearing. Data were collected using a word-monitoring and a closed-set identification task. Response times and percent correct scores were obtained for each task using signal to noise ratios (SNRs) of -3, 0, +3, +6, +9, and +12 dB. RESULTS: Both response time and percent correct measures were sensitive to changes in SNR, but greater sensitivity was found with the percent correct measures. Individual subject data showed that combining response time measures with percent correct scores improved test sensitivity for the monitoring task, but not for the closed-set identification task. CONCLUSIONS: The best test sensitivity was obtained by combining percent correct and response time measures for the monitoring task. Such an approach may hold promise for future clinical applications.

Adult↗

Correcting for measurement error in detecting unconscious cognition: comment on Draine and Greenwald (1998)

A. G. Greenwald, M. R. Klinger, and E. S. Schuh (1995) have proposed a regression method for detecting unconscious cognition in experiments that obtain measures of indirect and direct effects of stimuli with suspected unconscious effects. Their indirect-on-direct-measure regression approach can produce misleading evidence for indirect effects in the absence of direct effects when the direct-effect measure has typical measurement error. This article describes an errors-in-variables variant of the regression method that corrects for error in the direct-effect measure. Applied to the uses of the regression method by S. C. Draine and A. G. Greenwald (1998) in this issue, the errors-in-variables method affirms substantial evidence for indirect effects in the absence of direct effects.

Cognition↗

Measurement and correction of the effects of lag on contrast-detail test results in fluoroscopy.

Persistence of the video signal between TV frames, an effect also known as image lag, can lead to anomalously good contrast-detail test results for fluoroscopy systems. In this practical paper, a simple method is described which quantifies lag in fluoroscopy systems and corrects for its effect on threshold contrast. A digital framestore was used to acquire temporally contiguous fluoroscopy images. Correlation of the variance between an initial base TV frame and successive later frames was then measured via the correlation coefficient. Plotted against time, this function defines a time constant which characterizes the rate at which the initial variance pattern is replaced by incoming quantum noise. A survey of seven fluoroscopy units incorporating vacuum TV camera tubes found a mean time constant of 0.06 s. The relative change in contrast-detail performance was then measured as a function of applied digital frame averaging for two separate fluoroscopy units. A time constant was found for each frame averaging mode using the correlation of variance between frames. These measurements were used to derive a function which corrects contrast-detail results obtained for a unit with a measured nominal time constant to the typical vacuum camera tube time constant of 0.06 s. The correction is shown to significantly reduce the spread of contrast-detail results obtained over a range of temporal filtration settings.

Algorithms↗