Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Differences in elbow flexion torque measured concentrically, eccentrically, and isometrically.

The purposes of this study were to describe torque-velocity relationships during concentric, eccentric, and isometric testing of elbow flexor muscles and to determine test-retest reliability of a specific isokinetic testing protocol. Thirty healthy women were tested using an isokinetic dynamometer at velocities of 0 degrees, 30 degrees, 120 degrees, and 210 degrees/sec. Reliability was assessed in 20 of the subjects by retesting concentric and eccentric torques at 30 degrees and 120 degrees/sec after a 30-minute rest interval. The highest torque from three maximal efforts was considered to be peak torque. Mean eccentric peak torque was greater than either isometric or concentric peak torque; as isokinetic test velocity increased, the differences between concentric and eccentric torques became larger. Intraclass correlation coefficients ranged from .72 to .83, indicating lack of consistency between test and retest torques. Consecutive concentric-eccentric testing and lack of mechanical stabilization might have contributed to test-retest variability and to the relatively small differences between concentric and eccentric torques. Continued study of reliability of isokinetic testing protocols and further investigation of concentric-eccentric torque-velocity relationships are advocated.

Adult↗

EMG to torque relationship in rectus abdominis muscle. Results with repeated testing.

Rectus abdominis muscles of young healthy female volunteers were studied to determine both the maximum strength in isometric flexion and the relation between the surface electromyogram (RMS EMG) and torque. Both the upper and lower portions of the abdominal muscle were studied during graded increase and decrease of torque. Repeated testing was performed over 6 weeks. The form of the relation between torque and EMG was better described by a quadratic than by a linear regression relationship, but with considerable variability about the best-fit line. The torque-increasing and torque-decreasing parts of each test were different and were analyzed separately. After 6 weeks of repeated testing, maximum voluntary isometric flexion torque increased 16.8% (P less than 0.01). There was a decrease in the ratio of electromyographic activity to torque production, which was statistically significant in the torque-increasing recordings. These changes in maximum torque and in the EMG-torque relation were attributed to learning through a test-retest effect, rather than to a true change in muscle characteristics. These findings, which show changes in normal subjects undergoing repeated testing, do not support the reliability of isometric strength measurements, or measurements based on RMS EMG recordings, for quantifying abdominal muscle function in patients with back pain, or those undergoing strengthening exercises.

Abdominal Muscles↗

Torque-velocity characteristics and muscle fiber type in human vastus lateralis.

The relationship between torque-velocity characteristics of the knee extensors during isokinetic contractions and muscle fiber type of the vastus lateralis, determined from two muscle biopsy samples, was investigated in 12 male and 18 female subjects. Peak torque, corrected for the effect of gravity and impact artifact, was classified as corrected peak torque. The torque measured 30 degrees from full extension and, corrected for gravity, was classified as corrected torque at 30 degrees. No significant correlations were found between the percentage of fast-twitch fibers (%FT) or the relative area of FT fibers (%FTA) and corrected peak torque values for any of the velocities tested or the knee angles where corrected peak torques were measured. However, significant inverse relationships were determined for corrected torque at 30 degrees at all but the fastest velocity (270 degrees/s) and both %FT and %FTA for the male subjects. These results reveal that muscle fiber type of the vastus lateralis, based on duplicate muscle samples, is not related to the peak torque actually generated by the knee extensors but may influence the shape of the torque output for maximal contractions sustained over the entire range of motion.

Adult↗

The effect of cryotherapy on eccentric plantar flexion peak torque and endurance.

OBJECTIVE: The effects of cryotherapy on eccentric torque production and muscle endurance have been controversial. Our intent was to examine the effect of cryotherapy on isokinetic eccentric plantar flexion peak torque at 30 degrees /sec and 120 degrees /sec and on endurance at 120 degrees /sec. DESIGN AND SETTING: SUBJECTS WERE TESTED ON AN ISOKINETIC DYNAMOMETER FOR PEAK TORQUE AND ENDURANCE AND WERE THEN RANDOMLY ASSIGNED TO ONE OF FOUR GROUPS: (a) peak torque measurements at 30 degrees /sec and 120 degrees /sec after a 30-minute 10 degrees C ice bath immersion, (b) peak torque measurements at 30 degrees /sec and 120 degrees /sec without ice bath immersion (control), (c) endurance measurement at 120 degrees /sec after a 30-minute 10 degrees C ice bath immersion, and (d) endurance measurement at 120 degrees /sec without ice bath immersion (control). Subjects completed each of the four experimental conditions with 7 to 14 days between conditions. SUBJECTS: Eleven male and 11 female volunteers (mean age, 23.8 +/- 3.5 years) were screened for normal ankle range of motion, past history of lower extremity injury, and contraindications to cryotherapy. MEASUREMENTS: Dependent t tests were used to analyze practice session data in order to establish reliable baseline measurements. A 2 x 2 analysis of variance (ANOVA) with repeated measures (p < .05) was used to analyze peak torque data. A one-way ANOVA (p < .05) was used to analyze endurance data in the form of total work. RESULTS: Velocity significantly affected peak torque production, with eccentric peak torque values significantly higher at 120 degrees /sec than at 30 degrees /sec for both the control and the immersion conditions. Cryotherapy had no effect on eccentric peak torque at either 30 degrees /sec or 120 degrees /sec, but it increased eccentric total work (endurance) at 120 degrees /sec. CONCLUSIONS: Cryotherapy has long been known to have beneficial therapeutic effects. In our study, cryotherapy did not significantly affect eccentric peak torque, but it did increase muscle endurance. An athlete can reap the beneficial effects of cryotherapy, such as pain reduction, vasoconstriction, and edema control, without compromising eccentric force production or endurance.

Journal Article↗

Prophylactic ankle braces and knee varus-valgus and internal-external rotation torque.

CONTEXT: Although prophylactic ankle bracing has been shown to be effective in reducing the incidence of ankle sprains,how these ankle braces might affect the other joints of the lower extremity is not clearly understood. OBJECTIVE: To determine the effects of a prophylactic ankle brace on knee joint varus-valgus and internal-external rotation torque during a drop landing onto a slanted surface. DESIGN: A repeated-measures design. SETTING: Biomechanics research laboratory. PATIENTS OR OTHER PARTICIPANTS: Twenty-four physically active college students. INTERVENTION(S): Participants were tested in a brace and no brace condition. MAIN OUTCOME MEASURE(S): We measured 3 dependent variables:(1) peak ankle inversion-eversion torque, (2) peak knee varus-valgus torque, and (3) peak knee internal-external rotation torque. A force plate was used to collect ground reaction force data, and 6 motion analysis cameras collected kinematic data during the unilateral drop landing. An adjustable bar was hung from the ceiling, and a slant board was positioned over the center of the force plate, so that the ankle of the participant's dominant leg would invert upon landing. Peak torque was measure din both the brace and no-brace conditions. The average of the peak values in 3 trials for both conditions was used for the statistical analysis. RESULTS: Ankle eversion torque was significantly greater in the brace condition (F1,23 19.75, P < .01). Knee external rotation torque was significantly greater in the brace condition(F1,23 4.33, P <.05). Valgus knee torque was smaller in the brace condition, but the difference was not statistically significant(F1,23 3.45, P .08). CONCLUSIONS: This study provides an important first step in understanding the effects of prophylactic ankle bracing on other joints of the lower extremity. We found that prophylactic ankle bracing did have an effect on knee torque when the subject was landing on a slanted surface. Specifically, knee external rotation torque increased when the ankle was braced.

Journal Article↗

Peak torque of quadriceps and hamstring muscles in basketball and soccer players of different divisions.

Basketball and soccer are two games with different training and playing procedures. The purpose of this study was to examine the maximal voluntary peak torques of the quadriceps and hamstring muscles, and the torque ratio between these muscle groups in basketball players (n = 61) and soccer players (n = 51) participating in teams of different divisions. Isokinetic peak torques were measured using the Cybex II isokinetic dynamometer at 60 and 180 degrees.s-1. Basketball players of the national team produced higher peak torque values of quadriceps muscles than the other basketball players of different divisions (p < 0.05 to p < 0.001). Hamstring peak torques of the national basketball team were significantly higher the only velocities measured compared with the players from division II and IV (p < 0.05). Peak torque values of quadriceps muscles relative to body weight were significantly higher in the national basketball team compared with basketball players from division I. No significant differences were found in peak torque values of quadriceps and hamstring muscles within the different basketball and soccer divisions. Peak torque expressed in absolute terms was significantly higher in basketball players than in soccer players (p < 0.05 to p < 0.001). However, these differences were not significant when the strength of quadriceps and hamstring muscles was expressed relative to body weight. The H/Q ratio did not differ either ditto among the different divisions of basketball and soccer players. Based on the data obtained in this study, we concluded that the subjects' body weight have a decisive effect on the production of peak torque values of quadriceps and hamstring muscles in basketball and soccer players. Furthermore that the playing in different divisions, as well as participating in different sports, i.e. basketball or soccer, have surprisingly small effects on the peak isokinetic torque production of the quadriceps and hamstring muscles.

Adult↗

Relative contributions of muscle activation and muscle size to plantarflexor torque during rehabilitation after immobilization.

Muscle atrophy is clearly related to a loss of muscle torque, but the reduction in muscle size cannot entirely account for the decrease in muscle torque. Reduced neural input to muscle has been proposed to account for much of the remaining torque deficits after disuse or immobilization. The purpose of this investigation was to assess the relative contributions of voluntary muscle activation failure and muscle atrophy to loss of plantarflexor muscle torque after immobilization. Nine subjects (ages 19-23) years with unilateral ankle malleolar fractures were treated by open reduction-internal fixation and 7 weeks of cast immobilization. Subjects participated in 10 weeks of rehabilitation that focused on both strength and endurance of the plantarflexors. Magnetic resonance imaging, isometric plantarflexor muscle torque and activation (interpolated twitch technique) measurements were performed at 0, 5, and 10 weeks of rehabilitation. Following immobilization, voluntary muscle activation (56.8 +/- 16.3%), maximal cross-sectional area (CSA) (35.3 +/- 7.6 cm(2)), and peak torque (26.2 +/- 12.7 N-m) were all significantly decreased ( p < 0.0056) compared to the uninvolved limb (98.0 +/- 2.3%, 48.0 +/- 6.8 cm(2), and 105.2 +/- 27.0 N-m, respectively). During 10 weeks of rehabilitation, muscle activation alone accounted for 56.1% of the variance in torque ( p < 0.01) and muscle CSA alone accounted for 35.5% of the variance in torque ( p < 0.01). Together, CSA and muscle activation accounted for 61.5% of the variance in torque ( p < 0.01). The greatest gains in muscle activation were made during the first 5 weeks of rehabilitation. Both increases in voluntary muscle activation and muscle hypertrophy contributed to the recovery in muscle strength following immobilization, with large gains in activation during the first 5 weeks of rehabilitation. In contrast, muscle CSA showed fairly comparable gains throughout both the early and later phase of rehabilitation.

Adult↗

Using recurrent artificial neural network model to estimate voluntary elbow torque in dynamic situations.

Muscle modelling is an important component of body segmental motion analysis. Although many studies had focused on static conditions, the relationship between electromyographic (EMG) signals and joint torque under voluntary dynamic situations has not been well investigated. The aim of this study was to investigate the performance of a recurrent artificial neural network (RANN) under voluntary dynamic situations for torque estimation of the elbow complex. EMG signals together with kinematic data, which included angle and angular velocity, were used as the inputs to estimate the expected torque during movement. Moreover, the roles of angle and angular velocity in the accuracy of prediction were investigated, and two models were compared. One model used EMG and joint kinematic inputs and the other model used only EMG inputs without kinematic data. Six healthy subjects were recruited, and two average angular velocities (60 degrees s(-1) and 90 degrees s(-1)) with three different loads (0 kg, 1 kg, 2 kg) in the hand position were selected to train and test the RANN between 90 degrees elbow flexion and full elbow extension (0 degrees). After training, the root mean squared error (RMSE) between expected torque and predicted torque of the model, with EMG and joint kinematic inputs in the training data set and the test data set, were 0.17 +/- 0.03 Nm and 0.35 +/- 0.06 Nm, respectively. The RMSE values between expected torque and predicted torque of the model, with only EMG inputs in the training data set and the test set, were 0.57 +/- 0.07 Nm and 0.73 +/- 0.11 Nm, respectively. The results showed that EMG signals together with kinematic data gave significantly better performance in the joint torque prediction; joint angle and angular velocity provided important information in the estimation of joint torque in voluntary dynamic movement.

Adult↗

Effects of 17-day spaceflight on electrically evoked torque and cross-sectional area of the human triceps surae.

The effects of spaceflight on triceps surae muscle torque and cross-sectional area (CSA) were investigated on four astronauts using electrically evoked contractions to by-pass neural control. Muscle twitch characteristics, ankle joint angle-twitch torque relation, frequency-torque relation, tetanic torque and fatigability were assessed before, during and after a 17-day Space Shuttle flight (STS-78). Muscle plus bone cross-sectional area (CSAm+b) was evaluated before and after the flight. Whereas no changes in muscle function were observed during the flight, marked alterations were found during the recovery period. Peak twitch (PTw) and tetanic torques at 50 Hz (PT50) continued to fall up to the 8th recovery day (R+8) on which losses in PTw and PT50 were 24.4% (P<0.01) and 22.0% (P<0.01), respectively. The decline in PTw was not joint-angle-specific. Post-flight, especially on R+8, torque decreased at all stimulation frequencies (1, 20, 30 and 50 Hz); however the shape of the frequency-torque curve, normalised for PT50, was not modified. Similarly, no changes in twitch kinetics were observed. Post- flight, an 8% (P<0.01) reduction in CSAm+b was found on R+2. Normalisation of PT50 values for CSAm+b showed a progressive loss in specific torque (PT50/CSAm+b), which was maximal on R+2 (19.5%, P<0.05). Also, fatigability during 2-min intermittent stimulation at 20 Hz increased throughout recovery, reaching a nadir of 16.4% (P<0.01) on R+15. In conclusion, 17 days of spaceflight resulted in significant changes in muscle function during the recovery phase, but not in microgravity. The disproportionate loss of torque compared with that of muscle size suggests the presence of muscle damage due to reloading in 1 g.

Adult↗

Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating.

There is no consensus over whether screw fixation for anterior cervical plating should include the posterior cortical shell of the vertebral bodies or not. Thus, the purpose of this study was to investigate the function of the posterior cortical shell with respect to maximal screw torque and pullout force. Twenty-four fresh frozen human cervical vertebrae coming from six spinal segments C4-C7 were used. They were scanned for bone mineral density (BMD) and then assigned to two groups with comparable bone density and segmental distribution. The posterior longitudinal ligament was resected carefully and two parallel burr holes were drilled into each vertebral body. The posterior cortical shell was removed in one burr hole, using a 6-mm steel burr, producing a shallow excavation with a depth of approximately 2 mm. An ABC screw was inserted into each burr hole. The screw to be inserted into the hole with the posterior excavation was called "monocortical". In contrast, the contralateral screw was called "bicortical". Peak torque was measured in one group, while pullout force was analyzed using the specimens of the second group. Mean value and standard deviation were calculated for peak torque and pullout force with respect to the type of fixation. A paired t-test was used to determine the effect of fixation type on peak torque and pullout force. Pearson moment correlation coefficients were calculated to determine the effect of BMD on peak torque and pullout force with respect to whether the screw was "mono- or bicortical". A 95% level of significance was used for all tests. No significant differences for peak torque and pullout force could be found comparing monocortical and bicortical screw fixation. However, for both monocortical and bicortical screw fixation, a positive correlation was seen for peak torque versus BMD and for pullout force versus bone mineral density, respectively. The importance of the posterior cortical shell for screw pullout force and screw peak torque seems to be negligible. In constrast, BMD greatly influences both peak torque and pullout force for both types of fixation.

Bone Density↗

Materials-induced variation in the torque expression of preadjusted appliances.

The purpose of this article is to comprehensively investigate the sources of variation in the expression of torque in preadjusted appliances. Variables related to properties of materials were systematically analyzed, including (1) the inability to fill the slot because of the size difference of archwires and bracket slot, (2) irregularities from the manufacturing process of brackets precluding proper engagement, (3) differences in the stiffness of wire alloys engaged to the bracket slot, (4) variations between actual and reported bracket torque values, and (5) ligation modes, all of which might account for increased third-order clearance or bracket-archwire "play." The effect of these variations on the expression of torque is discussed, and the net buccolingual inclinations are provided as a function of wire size and composition for common bracket slot-archwire combinations. Most reports published on this issue indicate a loss of torque control as high as 100% of the prescribed value. Furthermore, the fallacy of transferring the ideal crown inclination to the torque prescribed in the bracket is illustrated, along with the underestimation of the prescribed torque relative to the proper tooth crown. The realistically required torque is analyzed to its constituent components, involving tooth inclination, compensation for the slot-wire play, and incomplete ligation with elastomeric ligatures. Based on the evidence available, it is proposed that a high-torque prescription should be selected to account for the lack of full expression of the prescribed torque that occurs clinically.

Dental Alloys↗

Age-related changes in hip abductor and adductor joint torques.

OBJECTIVE: To test the hypothesis that older age significantly affects hip abduction and adduction joint torque-time generating capability in women. DESIGN: Cross-sectional study, wherein subjects were tested in a supported standing position. SETTING: University human performance laboratory. PARTICIPANTS: Seventy-six healthy, adult women (38 young; 38 old). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The dependent variables were peak isometric torque and its corresponding torque rate and average peak isokinetic torque. Age group differences were assessed by analysis of variance. RESULTS: Isometric peak torques were significantly lower in older women (P</=.001) for hip abduction (34%) and adduction (24%). Decreases with age were also significant for isometric rates of torque for both muscle groups (P</=.001). Average isokinetic peak torque of hip abduction and adduction showed even greater declines in older women versus the young (P</=.001) with losses of 44% and 56%, respectively. CONCLUSIONS: The hip abductor and adductor torques showed relatively marked age-related changes. To enhance balance assessment and treatment, and to reduce the risk of falls and related injuries in older women, greater focus should be placed on understanding the role of joint torque-time changes on frontal plane balance control.

Accidental Falls↗

Torque and EMG in rotation extension of the torso from pre-rotated and flexed postures.

BACKGROUND: Back injury is a common place in our society. Up to two-thirds of back injuries have been associated with trunk rotation. However, the torque production ability with a rotated spine and electromyographic activity of trunk muscles in such efforts is poorly understood. Therefore, the objectives of this study are to study torque production capacity of variously rotated and flexed trunk and to measure the EMG of selected trunk muscles in these activities. METHODS: Nineteen normal young subjects (7 males and 12 females) were recruited. Subjects were stabilized on a posture-stabilizing platform and were instructed to assume a flexed and right rotated posture (20 degrees , 40 degrees and 60 degrees of rotation and 20 degrees , 40 degrees and 60 degrees of flexion) in a random order. The subjects were asked to exert their maximal voluntary contraction in the asymmetric plane of rotation-extension for a period of 5s. The surface EMG of the external and internal obliques, rectus abdominis, latissimus dorsi, erector spinae at the 10th thoracic and 3rd lumbar vertebral levels was recorded bilaterally along with the torque generated. FINDINGS: Whereas the torque generated was significantly affected by both rotation and extension in both genders (P<0.001), the EMG was independent of rotation but affected by flexion in females only (P<0.01). The torques produced by both genders in each of the nine postures was significantly different from each other (P<0.001). The EMG demonstrated a trend of increase with increasing rotation and flexion. The response surfaces of normalized peak EMG of the right external oblique and internal oblique was somewhat similar, indicating a rotator torque and a stabilizing effect. The left latissimus dorsi and right external oblique provided the rotational torque and the right erector spinae provided the extensor effort. Since the rotation-extension was performed in the plane of asymmetry, the effort required the recruitment of muscles involved in left rotation, stability of rotated spine and an extensor effort. INTERPRETATION: The torque production capacity of the human trunk is posture dependent and declines with increasing rotation. However, with increasing rotation and flexion, the magnitude of EMG increases. This implies that with increasing asymmetry, it requires more muscle effort (thus tissue stress) to generate less torque. Increasing asymmetry tends to weaken the system and may enhance chances of injury.

Abdomen↗

Muscle enhancement using closed-loop electrical stimulation: volitional versus induced torque.

In cases of partial deficiency of muscle activation capacity, force augmentation can be achieved by hybrid activation, i.e., by combining electrical stimulation (ES) with volitional activation. In this activation modality the shares of the volitional and induced torques within the overall hybrid torque are unknown. The purpose of this study was to suggest a computational approach to parcel out the volitional and stimulation induced components of joint torque generated during combined voluntary and electrical activation of the Tibialis Anterior muscle (TA). For this purpose, isometric contraction of the TA was studied on 5 healthy subjects, using an activation protocol involving ES alone, volitional activation alone and hybrid activation. Ankle torque and TA EMG were measured. A computational algorithm was developed to dissociate the volitional from the overall torque, based on EMG filtering and on pre-measured calibration curves of volitional torque versus EMG. The results indicated that for a certain hybrid torque there is a linear decaying relationship between the induced torque and the volitional torque shares. Moreover, based on a defined enhancement ratio, the results indicate that within the range of stimulation intensities, there exist regions of increased facilitation, in which the stimulation efficiency is higher under combined compared to isolated conditions.

Adult↗

An analysis of symmetry of torque strength of the forearm under resisted forearm rotation in normal subjects.

PURPOSE: To establish normative pronation and supination torque values in right-handed adults without evidence of upper-extremity dysfunction or impairment in the forearm positions of neutral, pronation, and supination. METHODS: Fifty-one normal right-handed participants ages 22 to 45 years were enrolled and tested in this study using a custom device that incorporated a torque cell and a grip system that produced a digital recording of the peak torque during maximal resisted pronation and supination in positions of neutral forearm rotation, 60 degrees pronation, and 60 degrees supination. RESULTS: The greatest peak torque strength for both male and female participants was found during resisted pronation in the supinated position. The peak torque values averaged 11.9 +/- 3.7 N.m on the right side and 10.4 +/- 3.3 N.m on the left side for men, and 6.0 +/- 1.4 N.m on the right side and 5.0 +/- 1.2 N.m on the left side for women. The weakest torque strengths were resisted pronation in the pronated position and resisted supination in the supinated position. CONCLUSIONS: Torque strength measurements are reliable and should be collected when treating patients with forearm dysfunction. Maximal torque follows the same pattern related to hand dominance as grip strength. Men generate average torque strengths that are approximately twice the magnitude of those generated by women.

Adult↗

Static torque-angle relation of human elbow joint estimated with artificial neural network technique.

Static relations between elbow joint angle and torque at constant muscle activity in normal volunteers were investigated with the aid of an artificial neural network technique. A subject sat on a chair and moved his upper- and forearm in a horizontal plane at the height of his shoulder. The subject was instructed to maintain the elbow joint at a pre-determined angle. The wrist was then pulled to extend the elbow joint by the gravitational force of a weight hanging from a pulley. Integrated electromyograms (IEMGs), elbow and shoulder joint angles and elbow joint torque were measured. Then the relation among IEMGs, joint angles and torque was modeled with the aid of the artificial neural network, where IEMGs and joint angles were the inputs and torque was the output. After back propagation learning, we presented various combinations of IEMGs, shoulder and elbow joint angles to the model and estimated the elbow joint torque to obtain the torque-angle relation for constant muscle activation. The elbow joint torque increased and then decreased with extension of the elbow joint. This suggests that if the forearm is displaced from an equilibrium point, the torque angle relation would not act like a simple spring. In a view of the musculoskeletal structure of the elbow joint, the relation between the elbow joint angle and the moment arm of the elbow flexor muscles seems to have a dominant effect on the torque-angle relation.

Adult↗

Stereotypic muscle-torque patterns are systematically adopted during acquisition of a multi-articular kicking task.

Motor-control mechanisms used to learn multi-joint (kinematically indeterminate) movements, which involve the control of intersegmental dynamics, are poorly understood, because the few kinetic studies which examined them studied only a few trials performed early and late in learning. Therefore, we examined changes in movement kinematics and kinetics accompanying multi-joint movement acquisition to address the following questions: Once subjects can produce accurate movements, do motor patterns (i.e. net muscle torques) change with further learning? Are motor patterns learned using a systematic strategy? Following learning, are the same motor patterns consistently used for movement production? Subjects performed 16 blocks of 16 trials of a discrete weighted (mass = 1.674 kg) kicking movement, involving hip, knee, and ankle motion. They attempted to perform 400 ms spatially accurate movements. Kinematics were recorded for the hip, knee, ankle, and toe of the kicking leg, and inverse dynamics were used to obtain net-muscle-torque profiles. Subjects did not adopt the motor patterns initially used to produce accurate movements. With further learning, net muscle torques became less variable both within and between blocks; inter-joint dependency of muscle torques increased, as evidenced by decreased variability in the pair of muscle torques which directly affect a segment's motion (i.e. hip-knee and knee ankle muscle torques); and inter-joint relationships of muscle torques became more phase-locked, with hip and knee torques being produced simultaneously, as were knee and ankle torques. As there was a progression across blocks until the preferred motor patterns were adopted, the learned stereotypic motor patterns were systematically selected.

Biomechanical Phenomena↗

Electrically evoked eccentric and concentric torque-velocity relationships in human knee extensor muscles.

The torque-velocity relationship, obtained during in situ conditions in humans, demonstrates a levelling-off of eccentric torque output at the isometric torque level, at least for knee extensor actions. In contrast, the in vitro force-velocity relationship for animal muscle preparations is characterized by a sharp rise in eccentric force from isometric maximum. A force-regulating 'protective' mechanism has been suggested during maximal voluntary high-tension eccentric muscle actions. To investigate this phenomenon, maximal voluntary and three different levels of submaximal, electrically induced torques were compared during isometric and low velocity (10, 20 and 30 degrees s-1) isokinetic eccentric and concentric knee extensor actions in 10 healthy, moderately trained subjects. Eccentric torque was higher than isometric during electrically evoked, but not during maximal voluntary muscle actions. In contrast, concentric torque was significantly lower than isometric for both maximal voluntary and submaximal, electrically evoked conditions. Comparisons of normalized torques (isometric value under each condition set to 100%) demonstrated that the maximal voluntary eccentric torque had to be increased by 20%, and the isometric by 10% in order for the maximal voluntary torque-velocity curve to coincide with the electrically stimulated submaximal ones. These results support the notion that a tension-regulating mechanism is present primarily during eccentric maximal voluntary knee extensor actions.

Actin Cytoskeleton↗