Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyglactin 910”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Clinical results with exposed polyglactin 910 resorbable membranes for guided tissue regeneration.

Three cases are presented where early exposure of a resorbable membrane occurred during guided tissue regeneration therapy. An antimicrobial regimen was selected to determine whether infection of exposed membranes could be controlled to the point of achieving acceptable clinical results without membrane removal. The results suggest that with the use of the antimicrobial regimen: (1) exposure is compatible with successful clinical results, and (2) removal is not necessary.

Absorbable Implants↗

Polyglactin 910 mesh for support of the donor defect of the double-pedicled rectus abdominis musculocutaneous flap.

The most significant concern in using the lower rectus abdominis musculocutaneous flap is creation of an eventration or even a frank hernia of the abdominal wall. Frequently, reinforcement using an alloplastic implant following closure of the double-pedicled donor defect is required. In an effort to avoid the use of any foreign materials, particularly if the goal in breast reconstruction is to use only autogenous tissues, strong consideration for incorporating an absorbable mesh is advocated to provide abdominal wall support.

Abdominal Muscles↗

Vicryl (polyglactin 910) mesh as a dural substitute in the presence of pia arachnoid injury.

Previously presented data showed that Vicryl mesh was a potentially effective dural grafting material. It is easily handled, relatively inexpensive, absorbed over time, and elicits a minimal inflammatory response. The present experimental project was conducted to investigate the effectiveness of a tightly woven version of the material as a watertight seal and to evaluate its performance in the presence of pia arachnoid injury. The mesh formed a seal promptly and adhesion formation was slight. Tightly woven Vicryl mesh appears to have a significant potential as an absorbable dural substitute.

Absorption↗

The use of Vicryl mesh (polyglactin 910) for implantation of hydroxyapatite orbital implants.

Hydroxyapatite (HA) implants currently are most commonly wrapped in donor sclera before implantation to facilitate placement within the orbit and allow attachment of the extraocular muscles. Although the risk of acquiring a transmittable disease through donor sclera is extremely low, some individuals remain concerned about receiving nonautologous material. As an alternative to sclera, autologous temporalis fascia, or autologous fascia lata, we have been wrapping HA in "Vicryl mesh" before insertion into the orbit. The Vicryl mesh-wrapped implant goes into the socket readily, allows one to easily attach the extraocular muscles, and has no risk of transmittable disease. In addition, the Vicryl mesh is readily available at most hospitals and is dissolvable.

Durapatite↗

Use of Vicryl (polyglactin 910) mesh to limit epidural scar formation after laminectomy.

A variety of substances have been used at laminectomy sites to prevent postoperative epidural scarring. Free grafts of autologous subcutaneous fat are commonly used both clinically and experimentally. The free fat grafts usually survive, but decrease in size by about 50%. Postoperatively, subcutaneous seroma has been observed with the use of fat grafts, as well as recurrent symptoms of neural compression by the graft that required additional operations. When compared to the use of free grafts after laminectomy in dogs, Vicryl mesh produced slightly more scarring, but consistently less than that observed in control animals. The Vicryl mesh was resorbed by a minimal chronic inflammatory response over about 45 days. Seven of 11 fat-grafted zones showed signs of necrosis, at times with a greater collection of inflammatory cells than that associated with the Vicryl mesh. Of the 4 fat-grafted zones that showed good survival, 2 had gross evidence of neural compression. No surgical zone treated with Vicryl mesh exhibited evidence of neural compression. In view of these results, the use of Vicryl mesh at laminectomy sites may be a safer method of limiting postoperative epidural scar formation.

Animals↗

[Polyglactin 910 (Vicryl) net in myringoplasty. An animal experiment and clinical study].

According to studies by Dociu (1978), the resorption of Vicryl sutures causes only a slight foreign-body reaction in the back musculature of rats. Similarly, in experimental studies by Bowald et al. (1978) Vicryl mesh is reported to be an excellent material for use in the reconstruction of arteries; the chief virtue attributed to it is that it promotes cell proliferation during the healing process, and so promotes the growth of new arterial walls. Stimulated by Dociu's and Bowald's favourable results, we decided to study the influence of an impregnated, and hence stiffer, Vicryl mesh on the outcome of myringoplasties. Myringoplasties were performed on both ears of 15 cats. One ear drum of each cat was reconstructed with fascia and Vicryl mesh, the other (= control) ear drum with fascia only. In addition, myringoplasties with autologous fascia and Vicryl mesh were performed on 18 patients. The absorption of Vicryl mesh results in a temporary but pronounced foreign-body reaction. In consequence, the tympanic membrane temporarily thickens and is thoroughly vasculated. According to our findings Vicryl mesh does not promote the growth of a new tympanic membrane. In our patients we noticed pulpy swelling of the fascia after myringoplastic surgery with fascia and Vicryl mesh. From the above we conclude that Vicryl mesh is not suitable for splintage in myringoplastic surgery.

Animals↗

Study of the efficacy of Coated VICRYL Plus Antibacterial suture (coated Polyglactin 910 suture with Triclosan) in two animal models of general surgery.

OBJECTIVES: To evaluate the efficacy in vitro and in vivo of a new antibacterial suture (PGAB) compared with a traditional braided suture (PG). Our primary goals were to study microbiological effectiveness and impact on wound healing of PGAB vs PG. Secondary goal was to analyze influence on inflammatory response. METHODS: In vitro study: clinical samples of Staphylococcus epidermidis, Staphylococcus aureus, S. hominis, Staphylococcus haemolyticus, Staphylococcus auricularis, Enterococcus faecalis, Corynebacterium spp. and Escherichia coli were studied. We also implanted a flat mesh in 10 minipigs, four incisions each (two PG and two PGAB) two contaminated with S. epidermidis and two not contaminated. Finally, we performed four colic anastomosis in each of 10 minipigs, two contaminated with E. coli and two not contaminated (two PG and two PGAB). We studied the inflammatory and wound healing processes in both models. RESULTS: We observed a bactericidal efficacy of PGAB against grampositive, and bacteriostatic effect against E. coli. Mesh study: recovered CFU were lower in the group PGAB vs PG. In the group PGAB, inflammatory mediators' concentrations were lower. In the group PGAB, concentrations of wound healing mediators were normal. Colic anastomosis: recovered CFU were lower in the group PGAB vs the group PG. In the group PGAB we observed a reduction of inflammatory mediators. In the group PGAB we observed normalized concentrations of wound healing mediators. CONCLUSIONS: This study demonstrates microbiological efficacy of PGAB, that normalizes wound healing process, and an anti-inflammatory effect.

Anastomosis, Surgical↗

Vibrational and thermal study on the in vitro and in vivo degradation of a bioabsorbable periodontal membrane: Vicryl Periodontal Mesh (Polyglactin 910).

Fourier transform Raman (FT-Raman), attenuated total reflection/Fourier transform infrared (ATR/FT-IR) spectra and differential scanning calorimetry (DSC) measurements were performed on a biodegradable periodontal membrane, the Vicryl periodontal mesh, in order to study its in vitro and in vivo degradation mechanism and kinetics. The hydrolitic in vitro degradation was investigated in two aqueous media: a saline phosphate buffer (SPB, pH=7.4) and a 0.01 M NaOH solution. Moreover, a membrane implanted in vivo for 4 weeks for treatment of contiguous vertical bony defects, was examined. Vibrational and thermal measurements show that the Vicryl membrane presents a semicrystalline structure. It degrades faster in the NaOH solution than in the SPB and degradation occurs heterogeneously with a progressive increase in the percentage of crystallinity and shortening of the polymeric chains both in vitro and in vivo. The trends of % weight loss and IR I627/I1415 intensity ratio (identified as a marker of crystallinity) are discussed in comparison with the DSC results. The IR I627/I1415 intensity ratio and Xc% allow to determine the % weight loss undergone by the membrane degraded in vivo. The result obtained shows that the Vicryl membrane degrades faster in vivo than in vitro with the formation of oligomers which are more easily absorbed by the surrounding tissues than they are soluble in the degradation media examined.

Journal Article↗

Vicryl (polyglactin 910) in cataract surgery. A controlled trial.

In a controlled, randomized trial in 45 cataract operations a new synthetic absorbable suture (8-0 monofilament Vicryl, made by Ethicon), was compared with monofilament nylon or virgin silk normally used. There was a higher incidence of early complications-hyphaema, shallow anterior chamber, and choroidal detachment (15-4 per cent v. 0 per cent)-with the absorbable suture. But these differences were not significant at the 0-05 level and might well disappear with more operative experience, particularly the modified technique of knot-tying. In handling qualities Vicryl was superior to both 10-0 monofilament nylon and 8-0 virgin silk with the exception of knot-tying, in which it was inferior to 8-0 virgin silk. Vicryl is considered to be a useful absorbable suture in cataract surgery but knot-tying requires modification of technique.

Cataract Extraction↗