Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pamphlets”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

MIRD pamphlet no. 16: Techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates.

This report describes recommended techniques for radiopharmaceutical biodistribution data acquisition and analysis in human subjects to estimate radiation absorbed dose using the Medical Internal Radiation Dose (MIRD) schema. The document has been prepared in a format to address two audiences: individuals with a primary interest in designing clinical trials who are not experts in dosimetry and individuals with extensive experience with dosimetry-based protocols and calculational methodology. For the first group, the general concepts involved in biodistribution data acquisition are presented, with guidance provided for the number of measurements (data points) required. For those with expertise in dosimetry, highlighted sections, examples and appendices have been included to provide calculational details, as well as references, for the techniques involved. This document is intended also to serve as a guide for the investigator in choosing the appropriate methodologies when acquiring and preparing product data for review by national regulatory agencies. The emphasis is on planar imaging techniques commonly available in most nuclear medicine departments and laboratories. The measurement of the biodistribution of radiopharmaceuticals is an important aspect in calculating absorbed dose from internally deposited radionuclides. Three phases are presented: data collection, data analysis and data processing. In the first phase, data collection, the identification of source regions, the determination of their appropriate temporal sampling and the acquisition of data are discussed. In the second phase, quantitative measurement techniques involving imaging by planar scintillation camera, SPECT and PET for the calculation of activity in source regions as a function of time are discussed. In addition, nonimaging measurement techniques, including external radiation monitoring, tissue-sample counting (blood and biopsy) and excreta counting are also considered. The third phase, data processing, involves curve-fitting techniques to integrate the source time-activity curves (determining the area under these curves). For some applications, compartmental modeling procedures may be used. Last, appendices are included that provide a table of symbols and definitions, a checklist for study protocol design, example formats for quantitative imaging protocols, temporal sampling error analysis techniques and selected calculational examples. The utilization of the presented approach should aid in the standardization of protocol design for collecting kinetic data and in the calculation of absorbed dose estimates.

Humans↗

MIRD Pamphlet No 19: absorbed fractions and radionuclide S values for six age-dependent multiregion models of the kidney.

UNLABELLED: As one of the major organs of the excretory pathway, the kidneys represent a frequent source of radiopharmaceutical uptake in both diagnostic and therapeutic nuclear medicine. The unique organization of the functional tissues of the organ ensures transient changes in suborgan localization of renal activity. Current single-region dosimetric models of the kidneys, however, force the assumption of a uniform distribution of radioactivity across the entire organ. The average absorbed dose to the kidneys predicted by such models can misrepresent local regional doses to specific substructures. METHODS: To facilitate suborgan dosimetry for the kidneys, 6 new age-dependent multiregion kidney models are presented. The outer dimensions of the models conform to those used currently in single-region kidney models, whereas interior structures are defined for the renal cortex, the medullary pyramids with papillae (2 vertical and 3 horizontal), and the renal pelvis. Absorbed fractions of energy were calculated for both photon and electron sources (10 keV to 4 MeV) located in each source region within the 6 age-dependent models. The absorbed fractions were then used to assemble S values for radionuclides of potential interest in suborgan kidney dosimetry. RESULTS: For the adult, the absorbed dose to the renal cortex for (90)Y-labeled compounds retained within that subregion is approximately 1.3 times that predicted by the single-region kidney model, whereas the medullary dose is only 26% of that same single-region value. For compounds that are rapidly filtered in the kidneys, the renal cortex dose is approximately one-half of that predicted under the single-region model, whereas the tissues of the medullary pyramids receive an absorbed dose 1.5-1.8 times larger. CONCLUSION: The multiregion model described here permits estimates of regional kidney dose not previously supported by current single-region models. Full utilization of the new model, however, requires serial imaging of the kidneys with regions of interest assigned to the renal cortex and medulla.

Aging↗

MIRD Pamphlet No. 14: a dynamic urinary bladder model for radiation dose calculations.

The constant-volume urinary bladder model in the standard MIRD phantom has recognized limitations. Various investigators have developed detailed models incorporating more physiologically realistic features such as expanding bladder contents and residual volume, and variable urinary input rate, initial volume and first void time. We have reviewed these published models and have developed a new model incorporating these factors. The model consists of a spherical source with variable volume to simulate the bladder contents and a wall represented by a spherical shell of constant volume. The wall thickness varies as the source expands or contracts. The model provides for variable urine entry rate (three different hydration states), initial bladder contents volume, residual volume and first void time. The voiding schedule includes an extended nighttime gap during which the urine entry rate is reduced to one-half the daytime rate. Radiation dose estimates have been calculated for the bladder wall surface (including photon and electron components) and at several depths in the wall (electron component) for [18F]FDG, 99mTc-DTPA, 99mTc-HEDP, [99mTc]pertechnetate 99mTc-RBCs, 99mTc-glucoheptonate, 99mTc-MAG3, [123I]/[124I]/[131I]OIH and sodium [131I]iodide(Nal). The initial bladder volume and first void time that provide the lowest radiation dose to the bladder wall are determined separately for each compound to give guidance for establishing dose reduction protocols.

Algorithms↗

Level of reading difficulty in educational pamphlets and informed consent documents for cancer patients.

Nationwide samplings and data from the 1980 census suggest that a high proportion of patients cared for are functionally illiterate. Since educational materials and consent forms are often given to patients with little regard for their ability to read them, this study was designed to analyze the readability of educational materials and consent forms at the Cancer Center of Southern West Virginia at Charleston Area Medical Center. Results of the survey showed that although the median education of the 127 patients studied was 10th grade, more than 30 percent could not be expected to read at the 10th grade level. Most tested patient education materials required a reading level of 11th to 14th grade, and cooperative group consent forms required a college-level reading comprehension. If patient-directed written material is to serve its purpose, then outpatient populations should be surveyed and the reading level of written material adjusted accordingly.

Adolescent↗