Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microscopy, Acoustic”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Evaluation of left atrial wall elasticity using acoustic microscopy.

Left atrial wall elasticity is one of the important factors regulating left atrial stiffness and functions. The authors evaluated left atrial wall elasticity by measuring the sound speed through the left atrial wall, based on the hypothesis that high elasticity tissues will yield larger sound speed values through the tissue, and examined age-associated changes in left atrial wall elasticity. Left atrium specimens were obtained from 30 normal subjects (age, 15-95 years) at autopsy. An acoustic microscope, operating at 450 MHz, was used to measure the sound speed in the endocardium and the myocardium of the left atrium. The sound speeds in endocardium and myocardium demonstrated significant correlation with age (r = 0.74, p<0.0001 and r = 0.47, p<0.01, respectively). These findings indicate that left atrial wall elasticity increased with advancing age. These changes may lead to deterioration of left atrial compliance and eventual left atrial failure in older subjects.

Adolescent↗

Cell contraction caused by microtubule disruption is accompanied by shape changes and an increased elasticity measured by scanning acoustic microscopy.

The state of crosslinking of microfilaments and the state of myosin-driven contraction are the main determinants of the mechanical properties of the cell cortex underneath the membrane, which is significant for the mechanism of shaping cells. Therefore, any change in the contractile state of the actomyosin network would alter the mechanical properties and finally result in shape changes. The relationship of microtubules to the mechanical properties of cells is still obscure. The main problem arises because disruption of microtubules enhances acto-myosin-driven contraction. This reaction and its impact on cell shape and elasticity have been investigated in single XTH-2 cells. Microtubule disruption was induced by colcemid, a polymerization inhibitor. The reaction was biphasic: a change in cell shape from a fried egg shape to a convex surface topography was accompanied by an increase in elastic stiffness of the cytoplasm, measured as longitudinal sound velocity revealed by scanning acoustic microscope. Elasticity increases in the cell periphery and reaches its peak after 30 min. Subsequently while the cytoplasm retracts from the periphery, longitudinal sound velocity (elasticity) decreases. Simultaneously, a two- to threefold increase of F-actin and alignment of stress fibers from the cell center to cell-cell junctions in dense cultures are induced, supposedly a consequence of the increased tension.

Actins↗

Investigation of crossed SAW fields by scanning acoustic force microscopy.

We used multimode scanning acoustic force microscopy (SAFM) for studying noncollinearly propagating Rayleigh and Love wave fields. By analyzing torsion and bending movement of SAFM cantilever, normal and in-plane wave oscillation components are accessible. The SAFM principle is the down-conversion of surface oscillations into cantilever vibrations caused by the nonlinearity of the tip-sample interaction. Through mixing of complementary oscillation components, phase velocities of crossed Rayleigh waves on GaAs and crossed Rayleigh and Love waves on the layered system SiO2/ST-cut quartz were obtained simultaneously. Now, it is possible to investigate elastic properties of submicron areas through multimode SAFM measurements. Finally, we present mixing experiments of four SAWs on GaAs and discuss the various influences on the measured SAFM amplitude and phase contrast.

Journal Article↗

Corneal morphology in vitro after superficial keratectomy with q-switched Er:YSGG and free-running Er:YAG lasers.

PURPOSE: Examination of morphology in corneal ablation induced by a q-switched Er:YSGG (2.79 microm) laser and a free-running Er:YAG laser (2.94 microm). METHODS: Defined ablation of 6-mm diameter and 15, 30, 55, 90, and 120-microm depth was performed on freshly enucleated swine eyes. Er:YSGG laser parameters: fluence 1.6 J/cm2, frequency 6 Hz, spot-size 465 microm FWHM, scanning-mode, pulse number 1520 to 6210. Er:YAG laser parameters: fluence 3 J/cm2, frequency 1.5 Hz, spotsize 6 mm, wide area ablation, pulse number 2 to 13. Corneal morphology was analyzed by gross photography, histology, scanning electron microscopy, and scanning nearfield acoustic microscopy. RESULTS: Histology showed thermal damage of 5 to 15 microm in depth caused by the Er:YSGG laser in comparison with 10 to 20 microm by the Er:YAG laser. Average roughness of the ablated surface measured with scanning nearfield acoustic microscopy was 20 to 40 microm for the Er:YSGG laser and 5 to 15 microm for the Er:YAG laser. These data confirm the subjective impression of images created by scanning electron microscopy and gross photography. CONCLUSIONS: Although the Er:YAG laser system appeared to demonstrate a smoother corneal surface than the q-switched Er:YSGG laser, the thermal damage in either case poses a potential limitation for clinical use in lamellar refractive surgery.

Animals↗

Micromechanical properties of demineralized dentin collagen with and without adhesive infiltration.

In a previous study, we reported the upper limit of Young's modulus of the unprotected protein at the dentin/adhesive interface to be 2 GPa. In this study, to obtain a more exact value of the moduli of the components at the d/a interface, we used demineralized dentin collagen with and without adhesive infiltration. The prepared samples were analyzed using micro-Raman spectroscopy (micro RS) and scanning acoustic microscopy (SAM). Using an Olympus UH3 SAM (Olympus Co., Tokyo), measurements were recorded with a 400 MHz burst mode lens (120 degrees aperture angle; nominal lateral resolution, 2.5 microm). A series of calibration curves were prepared using the relationship between the ultrasonically measured elastic moduli of a set of known materials and their SAM response. Finally, both the bulk and bar wave elastic moduli were computed for a set of 13 materials, including polymers, ceramics, and metals. These provided the rationale for using extensional wave measurements of the elastic moduli as the basis for extrapolation of the 400 MHz SAM data to obtain Young's moduli for the samples: E = 1.76 +/- 0.00 GPa for the collagen alone; E = 1.84 +/- 0.65 GPa for the collagen infiltrated with adhesive; E = 3.4 +/- 1.00 GPa for the adhesive infiltrate.

Bisphenol A-Glycidyl Methacrylate↗

Effect of sparse basis selection on ultrasonic signal representation.

Recently, adaptive sparse representations of ultrasonic signals have been utilized to improve the performance of scanning acoustic microscopy (SAM), a common nondestructive tool for failure analysis of microelectronic packages. The adaptive sparse representation of an ultrasonic signal is generated by decomposing it in a learned overcomplete dictionary using a sparse basis selection algorithm. Detection and location of ultrasonic echoes are then performed on the basis of the resulting redundant representation. This paper investigates the effect of sparse basis selection algorithms on ultrasonic signal representation. The overcomplete independent component analysis, focal underdetermined system solver (FOCUSS), and sparse Bayesian learning algorithms are examined. Numerical simulations are performed to quantitatively analyze the efficiency of ultrasonic signal representations. Experiments with ultrasonic A-scans acquired from flip-chip packages are also carried out in the study. The efficiency of ultrasonic signal representations are evaluated in terms of the different criteria that can be used to measure its performance for different SAM applications, such as waveform estimation, echo detection, echo location and C-scan imaging. The results show that the FOCUSS algorithm performs best overall.

Algorithms↗

Double-layer PVDF transducer and V(z) measurement system for measuring leaky Lamb waves in a piezoelectric plate.

This paper presents a new experimental measurement method for leaky Lamb waves propagating in a piezoelectric plate immersed in a conductive fluid. The measurement system is a low-frequency version of lens-less acoustic microscopy which has been developed based on a line-focus double-layer PVDF transducer. The transducer and its defocusing measurement system can perform V(z) measurements on a sample plate immersed in a fluid, and therefore can obtain the leaky Lamb wave velocities with high accuracy. An X-cut LiNbO(3) plate is investigated with this experimental measurement system to find out its fluid-loading effects, especially the conductive loading effects by water of various conductivities. Angular dependence of this conductive loading effect along different propagating directions on the X-cut LiNbO(3) plate is measured. It is found out the conductive loading effects are strongly dependent on the piezoelectric coupling factor. Theoretical calculations based on partial wave theory have also been carried out and compared with experimental data. Good agreements have been observed.

Biomedical Engineering↗

Distribution of the microelastic properties within the human anterior mitral leaflet.

Knowledge of the biomechanical properties of the mitral valve leaflets and their relation to histologic structure is of importance for understanding the leaflet movement characteristics under normal and pathologic conditions, but such knowledge is not yet available. The aim of this study was to determine biomechanical properties of the human anterior mitral leaflet on a microscopic scale. We used scanning acoustic microscopy (SAM) to examine the human anterior mitral leaflet. Sections of fixed human anterior mitral leaflet tissue were obtained from postmortem human anterior mitral leaflets (n = 5). We measured the speed of sound (nu(L)) in each histologic layer in three regions-of-interest (ROIs): these were at the annular edge, at the valve midpoint and close to the free edge. nu(L) varied in the three histologic layers (p < 0.01). It was higher in the fibrous layer (1.76 km/s) compared with the atrial layer (1.75 km/s) and ventricular layer (1.73 km/s). Also, nu(L) differed between positions along the length of the annulus-free edge line (p < 0.01), showing a decline from the annular edge (1.76 km/s) to the free edge (1.73 km/s), both as a whole and also within the atrial and the fibrous layer. These results demonstrate that the fibrous layer is stiffer than the atrial and ventricular layer and that the leaflet as a whole and within the atrial and the fibrous layer is stiffer at the annulus part in comparison with those near the free edge. (E-mail: ).

Adult↗

Principal surface wave velocities in the point focus acoustic materials signature V(z) of an anisotropic solid.

This paper deals with the point focus beam (PFB) acoustic materials signature V(z) of an anisotropic solid, and in particular how it tends to be dominated by a limited number of principal surface rays. These rays are associated with propagation directions in which the Rayleigh wave (RW), pseudo-surface acoustic wave (PSAW) or a lateral wave slowness has an extremum. The phenomenon is interpreted in terms of the complex azimuthally averaged reflectance function of the surface, and also explained on the basis of a ray model. We illustrate the phenomenon with a number of examples, pertaining to the surfaces of single crystal copper and a carbon-fibre epoxy composite. In the case of copper, which has a much larger acoustic impedance than the water couplant, the oscillations in V(z) are dominated by principal RW and PSAW, whereas for the composite there is no RW or pseudo-SAW to be discerned with acoustic microscopy (AM), and V(z) is dominated by principal lateral waves. The utility of PFB AM in the study of anisotropic solids is further elaborated with examples showing how V(z) is sensitive to surface orientation, and how V(z) is affected by the presence of a surface over layer. The phenomena examined in this paper expand the scope for determining materials characteristics, such as elastic constants, crystallographic orientation, residual stress and over layer properties, from PFB V(z) measurements.

Anisotropy↗

Chronological age modifies the microscopic remodeling process in viable cardiac tissue after infarction.

To define the impact of age on microscopic structural remodeling after myocardial infarction, the physical properties of infarct scar tissue and viable remote zone tissues in young (3 months) and older adult (18 months) Fischer rats were quantified with the use of high-frequency (50 MHz) high-resolution acoustic microscopy 3 months after coronary artery occlusion. We observed that integrated backscatter increased by 100% in the viable zones of old animals after infarction, but remained relatively unaffected in the same regions of younger animals. Mathematical models of myocardial scattering behavior indicated that a 25% increase in stiffness of the extracellular matrix materials in viable zones likely occurred in the older animals. Alterations in gross tissue collagen content were not responsible for this increased stiffness. These observations are compatible with the hypothesis that progressive age-related changes in the quality of the collagen (e.g., excessive age-related crosslinking) rather than its amount per se may have altered the stiffness of the extracellular matrix of remodeled viable tissue in older animals.

Aging↗

Temporal and spatial apodization in defocused acoustic transmission microscopy.

Two non-confocally adjusted spherical transducers are employed to implement an acoustic microscope operating in transmission with an approximately line-shaped point spread function (PSF). Such a PSF is of advantage in acoustic transmission line tomography and spatially resolved velocity measurements in solids. The foci of the transducers are viewed as diffraction-limited point transducers and appropriate time-selective signal acquisition is designed to restrict the ultrasound wave paths to the line connecting them. It is found that for typical commercially available transducers the largest contribution to the detected signal is not due to the direct ultrasound wave but due to the edge waves emanating from the rim of the focusing transducer. This poses constraints on achieving a line-shaped PSF in defocused acoustic transmission microscopy. It is shown that, due to the strong contribution from edge waves, it is impossible to achieve a line-shaped PSF in the case of application of a long exciting toneburst. The influence of the exciting pulse length, as well as the position of the time gate on the obtainable PSF is investigated.

Journal Article↗