Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MR”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Prostate cancer: a comparative study of 11C-choline PET and MR imaging combined with proton MR spectroscopy.

PURPOSE: Prostate cancer is difficult to visualise in its early stages using current imaging technology. The present study aimed to clarify the utility of 11C-choline PET for localising and evaluating cancer lesions in patients with prostate cancer by conducting a prospective comparison with magnetic resonance (MR) imaging combined with proton MR spectroscopy. METHODS: PET and MR imaging combined with proton MR spectroscopy were performed in 20 patients with prostate cancer. Correlations among the metabolite ratio of choline + creatine to citrate (Cho+Cr/Ci) on MR spectroscopy, serum PSA and maximum standardised uptake value (SUVmax) of (11)C-choline were assessed. The location of the primary lesion was assessed by the site of SUVmax and the laterality of the highest Cho+Cr/Ci ratio and confirmed by examination of surgical pathology specimens (n=16). RESULTS: PET exhibited a diagnostic sensitivity of 100% (20/20) for primary lesions, while the sensitivities of MR imaging and MR spectroscopy were 60% (12/20) and 65% (13/20), respectively. Weak linear correlations were observed between SUVmax and serum PSA (r=0.52, p<0.05), and between SUVmax and Cho+Cr/Ci ratio (r=0.49, p<0.05). Regarding the localisation of main primary lesions, PET results agreed with pathological findings in 13 patients (81%) (kappa=0.59), while MR spectroscopy results were in accordance with pathological findings in eight patients (50%) (kappa=0.11). CONCLUSION: This preliminary study suggests that 11C-choline PET may provide more accurate information regarding the localisation of main primary prostate cancer lesions than MR imaging/MR spectroscopy. A further clinical study of 11C-choline PET in a large number of patients suspected of prostate cancer will be necessary to determine the clinical utility of 11C-choline PET in patients who clinically require biopsy.

Aged↗

Current status of body MR imaging: fast MR imaging and diffusion-weighted imaging.

The recent technical advances in fast MR imaging have greatly enhanced the clinical value of MR imaging of the body. Advances in T(1)-weighted images have enabled the acquisition of dynamic contrast-enhanced MR imaging, which is currently central to hepatic MR imaging for detection and characterization of liver tumors and is also useful for the evaluation of myometrial invasion in uterine cor-pus cancer. Advances in rapid T(2)-weighted MR imaging with single-shot fast spin-echo images have enabled MR cholangiopancreatography and MR urography. Application of respiratory triggering can also provide T(2)-weighted images of high quality. Cine MR imaging utilizing ultrafast MR sequences enables the assessment of the respiratory motion of the lung for evaluating thoracic wall invasion by tumors. Diffusion-weighted images can provide excellent tissue contrast based on molecular diffusion and have the potential to demonstrate malignant tumors. Quantitative measurement of apparent diffusion coefficient values may also be valuable in distinguishing malignancies from benign lesions.

Diffusion↗

Biliary obstruction: findings at MR cholangiography and cross-sectional MR imaging.

Twenty-two patients with malignant biliary obstruction and 21 patients with suspected obstruction of biliary-enteric anastomoses were evaluated over a 12-month period with magnetic resonance (MR) cholangiography and cross-sectional MR imaging. In patients with malignant obstruction, MR cholangiography helped accurately determine the status of the biliary ductal system by identifying the exact location and extent of the obstruction and the severity of duct dilatation. In so doing, MR cholangiography helped determine whether percutaneous transhepatic cholangiography with antegrade stent placement or retrograde cholangiography with stent placement constituted the more suitable treatment. Cross-sectional MR imaging was necessary to identify the organ of tumor origin, define the tumor margins, and determine the stage of disease. This information helped evaluate the appropriateness of curative surgical therapy versus palliative drainage procedures. In patients with biliary-enteric anastomoses, MR cholangiography clearly depicted the site of the anastomosis and demonstrated the status of the intrahepatic ducts, thereby helping determine which patients would benefit from undergoing antegrade duct cannulation with a drainage procedure or perhaps balloon dilation. In some of these patients, MR cholangiography was sufficient to help plan therapeutic intervention. MR cholangiography also demonstrates the presence and size of biliary stones and associated findings such as intraductal tumor growth. In addition, MR cholangiography may obviate retrograde cholangiography, which can be technically difficult to perform.

Adult↗

Characterization of liver lesions with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT.

PURPOSE: To evaluate whether mangafodipir trisodium (Mn-DPDP)-enhanced magnetic resonance (MR) imaging surpasses dual-phase spiral computed tomography (CT) in differentiating focal liver lesions. MATERIALS AND METHODS: One hundred forty-five patients who had or were suspected of having focal liver lesions were included in a multicenter study and underwent dual-phase spiral CT and enhanced MR imaging. Image interpretations performed by independent experienced radiologists were compared with the final diagnosis that was based on all available clinical information (including histopathologic findings in 77 patients) and that was determined with consensus. Differences in classifications by using either enhanced MR imaging or dual-phase spiral CT were analyzed with the McNemar test, and receiver operating characteristic (ROC) curves were used to compare the diagnostic performance of enhanced MR imaging and dual-phase spiral CT. RESULTS: Lesion classification was correct in 108 (74%) patients with enhanced MR imaging and in 83 (57%) with dual-phase spiral CT (P =.001). Lesions were correctly classified as either malignant or benign in 123 (85%) patients with enhanced MR imaging and in 98 (68%) with dual-phase spiral CT (P =.001). Classification of lesions as either hepatocellular or nonhepatocellular was correct in 130 (90%) patients with enhanced MR imaging and in 93 (64%) with dual-phase spiral CT (P =.001). These differences remained when analyses were restricted to histopathologically confirmed diagnoses. Comparison of the ROC curves illustrated that enhanced MR imaging performance surpassed that of dual-phase spiral CT. CONCLUSION: Mn-DPDP-enhanced MR imaging is superior to dual-phase spiral CT in classification of focal liver lesions.

Adult↗

Anterior bundle of ulnar collateral ligament: evaluation of anatomic relationships by using MR imaging, MR arthrography, and gross anatomic and histologic analysis.

PURPOSE: To evaluate the gross and microscopic anatomy and the magnetic resonance (MR) imaging and MR arthrographic appearance of the anterior bundle of the ulnar collateral ligament (UCL) of the elbow. MATERIALS AND METHODS: The origin and insertion of the anterior bundle of the UCL, the bundle's relationship to the overlying flexor tendons, and the presence of a layered configuration were assessed through inspection and dissection of an elbow specimen. T1-weighted spin-echo MR imaging and MR arthrography in standard imaging planes and a coronal oblique plane were performed in eight other elbow specimens. Additional MR arthrography was performed in four specimens by using the coronal plane with the elbow in 20 degrees of flexion. The specimens were then cut in planes corresponding to those of the MR images. Histologic analysis of two specimens was performed. RESULTS: The anterior bundle of the UCL appeared as a low-signal-intensity structure on T1-weighted spin-echo MR and MR arthrographic images. It consisted of a uniform layer of parallel collagen fibers attaching proximally to the base of the medial epicondyle of the humerus and distally to the medial aspect of the coronoid process of the ulna (sublime tubercle). A layer of synovium separated the anterior bundle from the more superficial tendon of the flexor digitorum superficialis muscle. MR imaging-anatomic comparison in four (50%) specimens revealed separation between the anterior bundle of the UCL and the sublime tubercle. Results of histologic analysis of two of these specimens confirmed insertion of the anterior bundle of the UCL 3 and 4 mm distal to the articular margin. Ligamentous degeneration was detected in only one of these specimens. CONCLUSION: There is variability in the distal insertion of the anterior bundle, and this suggests that caution should be exercised in the diagnosis of its partial detachment from the sublime tubercle of the ulna.

Aged↗

Comparison of CT, low-field-strength MR imaging, and high-field-strength MR imaging. Work in progress.

To assess objectively the sensitivity and specificity of low-field-strength (0.064 T) magnetic resonance (MR) imaging, a prospective blind study of 280 examinations was performed to compare low-field-strength MR imaging with computed tomography (CT) and with high-field-strength (1.5-T) MR imaging of the cranium. The sensitivity (defined as the true-positive rate) with high-field MR imaging was superior to that with low-field MR imaging and CT in helping detect overall abnormalities. Sensitivities were generally similar over a broad range of specific cranial central nervous system diseases. Low-field and high-field MR imaging were equivalent in the blind diagnoses of neoplasms and white matter disease, whereas low-field MR and CT were equivalent in the blind diagnoses of contusion, subdural and epidural hematoma, sinus disease, normality, and abnormality. The specificities with low-field MR imaging and CT were substantially better than those with high-field MR imaging.

Brain↗

Chronic ankle instability: evaluation with MR arthrography, MR imaging, and stress radiography.

PURPOSE: To compare the efficacy of conventional magnetic resonance (MR) imaging, MR arthrography, and stress radiography in the detection of lateral collateral ligament abnormalities in patients with chronic ankle instability. MATERIALS AND METHODS: Seventeen patients with chronic lateral ankle instability underwent stress radiography, MR imaging, and MR arthrography after intraarticular injection of gadopentetate dimeglumine. Imaging findings were correlated with surgical findings. RESULTS: The anterior talofibular (ATF) ligament was torn in 14 patients, and the calcaneofibular (CF) ligament was torn in 10. MR arthrography was more accurate and sensitive in the detection of ATF tears than was MR imaging or stress radiography (P < or = .05). Associated injuries were detected with both MR imaging and MR arthrography. CONCLUSION: MR arthrography is a sensitive technique for detecting and staging tears of the lateral collateral ligaments.

Adult↗

Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography.

PURPOSE: To prospectively compare the diagnostic accuracy of computed tomography (CT) during arterial portography (CTAP) with that of unenhanced and ferumoxides-enhanced magnetic resonance (MR) imaging at 0.5 T in the detection of hepatic metastases. MATERIALS AND METHODS: Four pairs of radiologists independently assessed the metastatic involvement of 134 hepatic segments (31 with and 103 without metastasis) in 17 patients at unenhanced and ferumoxides-enhanced spin-echo and gradient-echo MR imaging (alone and in combination) and at CTAP. The diagnostic performance of the various imaging modalities was assessed by means of receiver operating characteristic analysis. RESULTS: The accuracy of CTAP, unenhanced MR imaging (combined unenhanced sequences), and ferumoxides-enhanced MR imaging (combined contrast material-enhanced sequences) was 0.925, 0.908, and 0.951, respectively. Ferumoxides-enhanced MR imaging was significantly more accurate (P < .05) than unenhanced MR imaging and CTAP. When 14 segments containing cysts were excluded, the difference between ferumoxides-enhanced MR imaging and CTAP was no longer statistically significant (P = .1). CONCLUSION: Ferumoxides-enhanced MR imaging is more accurate than unenhanced MR imaging and at least as accurate as CTAP for the detection of hepatic metastases.

Adult↗

Peritoneal tumor: MR imaging with dilute oral barium and intravenous gadolinium-containing contrast agents compared with unenhanced MR imaging and CT.

PURPOSE: To compare fat-suppressed, gadolinium-enhanced, breath-hold magnetic resonance (MR) imaging after administration of dilute oral barium solution with unenhanced MR imaging and computed tomography (CT) in the detection of peritoneal tumors. MATERIALS AND METHODS: In 24 patients in whom peritoneal tumor was known or suspected, double-contrast MR imaging and CT were performed prospectively. MR imaging included T1-weighted, fast spin-echo T2-weighted, and immediate and delayed gadolinium-enhanced, breath-hold, fast multiplanar sequences with fat saturation. Helical and conventional dynamic CT were performed with intravenously and orally administered contrast media. MR images and CT scans were reviewed independently and prospectively by different pairs of radiologists for presence of peritoneal tumor in 17 anatomic sites. Imaging findings were compared with surgical and histopathologic results. RESULTS: Of the 24 patients, 18 had peritoneal tumor confirmed at surgery. Detection of tumor sites was superior with double-contrast MR images (mean sensitivity, specificity, and accuracy, 84%, 87%, and 86%, respectively) compared with CT scans (mean sensitivity, specificity, and accuracy, 54%, 91%, and 74%, respectively). Double-contrast MR imaging enabled better detection of carcinomatosis and tumors less than 1 cm in diameter (75%-80%) than CT (22%-33%; P < .0001). CONCLUSION: Double-contrast MR imaging demonstrated more peritoneal tumors than CT or unenhanced spin-echo MR imaging.

Administration, Oral↗

Demonstration of nuclear translocation of the mineralocorticoid receptor (MR) using an anti-MR antibody and confocal laser scanning microscopy.

Using a synthetic peptide that corresponds to a unique region of the N-terminal domain of the human mineralocorticoid receptor (MR), amino acids 87-96, we have generated a polyclonal antibody, human (h) MRsN. This sequence shares no homology with the corresponding sequences of the glucocorticoid receptor or other steroid/thyroid hormone receptor superfamily members. Antibody hMRsN cross-reacts with MR from human, rat, and mouse cells and recognizes denatured MR from either crude preparations or partially purified rat kidney cytosol, rat colon, or recombinant hMR overexpressed in baculovirus-infected Sf9 cells. Immunoprecipitation of the native MR from either partially purified or crude preparations of rat kidney cytosol with hMRsN, followed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and silver stain, demonstrated a major protein band with a mol wt of 116 kilodaltons. In addition, using confocal laser scanning microscopy and digital image analysis, the immunocytochemical localization of the recombinant hMR over-expressed in Sf9 cells 24 h post-transfection was determined. In the absence of ligand, the MR was detected solely in the cytoplasm, after a 30-min exposure to 100 nM aldosterone the MR was perinuclear, and after 60 min, the MR was predominantly nuclear. To ascertain that this phenomenon was not unique to insect cells, aldosterone induced MR nuclear translocation in mouse macrophage cells was also demonstrated immunocytochemically, clearly indicating a role for nuclear translocation in MR function.

Amino Acid Sequence↗

Detection of knee hyaline cartilage defects using fat-suppressed three-dimensional spoiled gradient-echo MR imaging: comparison with standard MR imaging and correlation with arthroscopy.

OBJECTIVE: A preliminary study was done to prospectively compare fat-suppressed three-dimensional spoiled gradient-echo (3D SPGR) MR imaging with standard MR imaging for detection of defects in the hyaline cartilage of the knee, using arthroscopy as the reference standard. SUBJECTS AND METHODS: We studied 43 consecutive patients referred by two orthopedic surgeons for MR imaging of the knee. Twelve had arthroscopic correlation; they formed the basis of our study. Hyaline cartilage was imaged with a fat-suppressed 3D SPGR sequence with previously determined optimal imaging parameters. Our standard MR imaging study consisted of two-dimensional coronal T1-weighted spin-echo, sagittal dual-echo T2-weighted spin-echo, and axial multiplanar gradient-echo sequences. With arthroscopy as the reference standard, sensitivity and specificity of fat-suppressed 3D SPGR and standard MR images for detecting cartilage tears were determined by articular surface (eight surfaces in each patient: medial and lateral patellar facets, trochlear facets, femoral condyles, and tibial plateaus). Statistically significant differences in sensitivity and specificity were determined. RESULTS: Arthroscopy showed 15 cartilage defects in seven patients. The fat-suppressed 3D SPGR images had higher sensitivity (93%) than the standard MR images (53%, p = .03). Specificity was 94% for the fat-suppressed 3D SPGR images compared with 93% for the standard MR images (p > .05). The five false-positive articular surfaces on fat-suppressed 3D SPGR images were from focal signal change within the substance of the cartilage without a contour defect. Smoothly contoured thinning and loss of the trilaminar appearance of the hyaline cartilage at the lateral femoral notch was shown in all subjects and was considered a normal finding. CONCLUSION: Fat-suppressed 3D SPGR imaging is more sensitive than standard MR imaging for the detection of abnormalities of the hyaline cartilage in the knee. Routine use of this technique may strengthen the role of MR imaging for noninvasive evaluation of internal derangements of the knee.

Adolescent↗

Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation.

OBJECTIVE: Our purpose was to assess the accuracy of measurements of flow velocity and volume flow rate in an in vitro phantom and in healthy human volunteers using a cardiac-gated, segmented K-space, fast cine phase-contrast (PC) MR imaging technique with view sharing (fast PC). We compared this method with conventional cine PC MR imaging and Doppler sonography. SUBJECTS AND METHODS: Pulsatile flow was generated in a flow phantom that consisted of a cylindric tube having various degrees of tapered stenosis. Phase-encoded velocity maps were obtained using cine PC and fast PC MR imaging. Doppler sonography was also performed. Measurements of aortic and pulmonary artery peak systolic and minimum diastolic velocity and volume flow rate were then compared in eight healthy volunteers using the three imaging techniques. RESULTS: We found excellent agreement between fast PC and cine PC measurements of peak systolic velocity when regions of interest were drawn to exclude vessel margins (r > .99 for phantom studies, and r = .80 for human studies). Correlation between minimum diastolic velocity measurements by MR imaging was limited by noise that resulted from high encoding velocity settings. However, such correlation improved with signal averaging. When compared with predicted values of volume flow rates, both cine PC (r > .99) and fast PC (r = .97) MR imaging were more accurate than Doppler sonography (r = .78) in vitro. Measurements of cardiac output were adversely affected by low signal to noise, especially during diastole; estimates based on systolic forward flow resulted in better agreement between the two MR imaging methods. CONCLUSION: Fast PC MR flow quantification may prove to be a useful adjunct to routine MR studies for measurements of peak flow velocity. However, estimates of volume flow rate using fast PC MR imaging are limited because of increased noise during low diastolic flow as well as edge artifacts.

Adult↗

Clinical impact of MR spectroscopy when MR imaging is indeterminate for pediatric brain tumors.

OBJECTIVE: We undertook this study to determine if single-voxel proton (hydrogen) MR spectroscopy could have clinical impact on the management of pediatric brain tumors when MR findings were indeterminate. SUBJECTS AND METHODS: Eleven children (mean age, 9 years) being examined for brain tumors underwent MR imaging that revealed indeterminate criteria of enhancement, mass effect, and prolonged T1 and T2 signal. MR spectroscopy was then used to distinguish radiation necrosis from tumor in one patient, differentiate residual tumor from scarring in two patients, document early treatment response in three patients, and discriminate benign from malignant masses in five patients. RESULTS: In 10 of the 11 patients, spectra were successfully acquired. Based on the chemical analysis of the indeterminate area shown on MR imaging, clinical impact was achieved in these 10 patients. Clinical impact included treatment modification in five patients, follow-up studies replacing further treatment in three patients, and tumor characterization in the remaining two patients. Confirmation was by histology in four patients and by follow-up MR imaging and MR spectroscopy for up to 30 months in the remaining six patients. CONCLUSION: When MR imaging is indeterminate in evaluating pediatric brain tumors, MR spectroscopy can provide objective neurochemical information, thereby altering treatment.

Adolescent↗

[Gadolinium-enhanced MR imaging, T2-weighted MR imaging, and transurethral ultrasonography].

PURPOSE: To assess the value and problems of dynamic gadolinium-enhanced MR imaging, T2-weighted MR imaging, and transurethral ultrasonography(TUUS) in staging of urinary bladder cancer. MATERIALS AND METHODS: Dynamic gadolinium-enhanced MR imaging and FSE T2-weighted MR imaging of 64 patients with urinary bladder cancer who subsequently had surgery were retrospectively reviewed and compared with TUUS findings. RESULTS: Specificity for muscular invasion was 90.5% with TUUS, significantly better than with dynamic MR imaging (64.9%) (p < 0.05). The rates of overestimation of superficial cancer(pT1) with dynamic MRI and T2-weighted MR imaging were 35.1%(13/37) and 24.3%(9/37), respectively. The staging accuracy of invasive cancer(pT2 or over) was 85.2% with dynamic MR imaging, which was better than the rate of 75.0% achieved with T2-weighted MR imaging. CONCLUSION: Although TUUS was a better modality for diagnosing superficial cancer(pT1), dynamic MR imaging was found to be better for diagnosing invasive(pT2 or over) cancer.

Adolescent↗

MR imaging and MR spectroscopy of adenocarcinoma of the prostate.

INTRODUCTION: We examined the impact of magnetic resonance (MR) imaging and MR spectroscopy on the diagnosis and management of prostate cancer. METHODS: A Medline search was performed and the relevant articles reviewed. The salient points are discussed and summarised. RESULTS: MR imaging with phased-array and endorectal coils is not recommended for routine staging. It has a complementary role in improving the accuracy of local staging in patients with intermediate risk based on Partin's normogram. MR spectroscopy can be performed in conjunction with high-resolution anatomic MR imaging of the prostate. It exploits the increased choline and decreased citrate levels within malignant prostatic tissue compared with normal prostatic tissue, and can potentially improve the assessment of cancer location and extent within the prostate, as well as extracapsular spread in small retrospective studies. It also has the potential of providing a measure of the presence and extent of prostate cancer after therapy. CONCLUSION: MR imaging is indicated in staging patients with intermediate risk based on Partin's normogram. Combined MR imaging and MR spectroscopy of the prostate is a promising imaging tool which can contribute to the diagnosis and management of prostate cancer when combined with clinical, biochemical and histological data. Large prospective studies must be performed to ascertain the true clinical value of combined MR imaging/MR spectroscopy for the management of prostate cancer patients.

Adenocarcinoma↗

Head and neck paragangliomas: improved tumor detection using contrast-enhanced 3D time-of-flight MR angiography as compared with fat-suppressed MR imaging techniques.

BACKGROUND AND PURPOSE: MR imaging techniques have proved their efficacy in imaging the head and neck region. In this study, we compared T1-weighted, dual T2-weighted, and fat-suppressed MR imaging and unenhanced and contrast-enhanced 3D time-of-flight MR angiography sequences for detection of head and neck paragangliomas. METHODS: Thirty-one patients with 70 paragangliomas were examined. Four combinations of MR images were reviewed by two neuroradiologists: T1-weighted and dual T2-weighted fast spin-echo images, T1- and T2-weighted fat-suppressed fast spin-echo images, T1-weighted and contrast-enhanced T1-weighted fat-suppressed spin-echo images, and unenhanced and contrast-enhanced 3D time-of-flight MR angiograms. The randomized examinations were independently evaluated for image quality, presence of tumor, tumor size, and intratumoral flow signal intensity. The standard of reference for presence of tumor was digital subtraction angiography. Data were analyzed by using the logistic regression method. RESULTS: Mean sensitivity, specificity, and negative predictive values, respectively, were assessed by the two observers to be as follows: for dual T2-weighted fast spin-echo, 74%/99%/86%; for T2-weighted fat-suppressed fast spin-echo, 70%/100%/85%; for contrast-enhanced T1-weighted fat-suppressed spin-echo, 73%/100%/86%; and for unenhanced and contrast-enhanced 3D time-of-flight MR angiography, 89%/99%/93%. Sensitivity was significantly better for unenhanced and contrast-enhanced 3D time-of-flight MR angiography (P =.000028). More intratumoral flow signal intensity was depicted with unenhanced and contrast-enhanced 3D time-of-flight MR angiography. CONCLUSION: A combination of unenhanced and contrast-enhanced 3D time-of-flight MR angiography is superior for detecting paragangliomas and should be added to a standard imaging protocol, especially for patients with familial paragangliomas because they are more susceptible to multicentric disease.

Adult↗

Prostate cancer: evaluation with endorectal MR imaging and three-dimensional proton MR spectroscopic imaging.

PURPOSE: To establish the additional value of MR Spectroscopy (3D CSI MRS Three-dimensional Chemical Shift Imaging Magnetic Resonance Spectroscopy) to endorectal MR in the diagnosis and grading of prostate cancer. MATERIALS AND METHODS: MR and 3D CSI MR spectroscopy were performed in 53 patients with suspicion of prostate cancer on the basis of rectal exploration and/or transrectal ultrasound and/or the PSA levels. All the examinations were performed with a 1.5 T imager using an endorectal coil. We acquired axial and coronal T2-weighted FSE sequences, axial T1-weighted SE sequences and PRESS 3D CSI (Point Resolved Spectroscopy 3D Chemical Shift Imaging) sequences localized on the axial T2 images so as to include the prostatic gland while excluding the periprostatic fat. The MR examinations were evaluated by two radiologists unaware of the clinical data, transrectal ultrasound findings, PSA levels and histological findings. The MR and 3D CSI MRS findings were compared with the biopsy findings in 22 cases and with material obtained from laparoscopic prostatectomy in 31 cases. RESULTS: The histological examination revealed adenocarcinoma in 37 cases, prostatitis in 2 cases and no alterations in the remaining 14 cases. The morphologic MR scan showed a sensitivity of 76%, a specificity of 56%, an accuracy of 70%, a PPV of 80% and a NPV of 50%. By combining MR and 3D CSI MRS we obtained a sensitivity of 95%, a specificity of 81%, an accuracy of 91%, a PPV of 92% and a NPV of 87%. Elevated choline concentrations were found both in tumours with a low Gleason score (18 cases) and in those with a high Gleason score (19 cases); instead we found markedly reduced (n=9) or absent (n=4) citrate only in the tumours with a high Gleason score, while we found normal citrate levels in the 18 tumours with a low Gleason score. CONCLUSIONS: The 3D CSI MRS improved the reliability of endorectal MR in the diagnosis and characterisation of prostatic cancer. Moreover, the 3D CSI MRS findings demonstrated a linear correlation with tumour grade.

Adenocarcinoma↗

MR imaging, MR spectroscopy, and diffusion tensor imaging of sequential studies in neonates with encephalopathy.

BACKGROUND: Although the imaging, spectroscopic, and diffusion characteristics of brains of infants with neonatal encephalopathy have been described, the time course during which these changes evolve is not clear. The results of sequential MR imaging studies--including anatomic MR imaging, proton MR spectroscopy, and diffusion tensor imaging (DTI)--of 10 patients enrolled prospectively in a study of neonatal encephalopathy are reported to help to clarify the time course of changes in different brain regions during the first 2 weeks of life. METHODS: Ten neonates were prospectively enrolled in a study of the evolution of MR findings in neonatal encephalopathy and were studied 2 (8 patients) or 3 (2 patients) times within the first 2 weeks of life. The MR examination included spin-echo T1 and T2-weighted images, DTI, and long echo time (288 milliseconds) proton MR spectroscopy. Diffusion parameters (diffusivity [D(av)], fractional anisotropy [FA], and individual eigenvalues) were calculated for 10 1-cm2 regions of interest in each hemisphere that were placed based on anatomic landmarks. D(av) and FA were then measured manually in the same areas on a workstation. Metabolite ratios (NAA/Ch, Cr/Ch, Cr/NAA, Lac/Ch, and Lac/NAA) were calculated in 7 regions of interest. Imaging appearance, diffusion parameters, and metabolite ratios were then evaluated longitudinally (comparing with other studies on the same patient at different times) and cross-sectionally (comparing all studies performed on the same postnatal day). RESULTS: In most of the patients a characteristic evolution of DTI and MR spectroscopy parameters was seen during the first 2 weeks after birth. Although the anatomic images were normal or nearly normal on the first 2 days after birth in most patients, abnormalities were detected on DTI (both visually and by quantitative interrogation of D(av) maps) and proton MR spectroscopy (abnormal metabolite ratios). These parameters tended to worsen until about day 5 and then normalize, though in several patients abnormal metabolite ratios persisted. Of interest, as areas of abnormal diffusivity pseudonormalized within one region of the brain they would develop in other areas. Therefore, the pattern of injury looked very different when imaging was performed at different times during this evolution. CONCLUSION: Patterns of injury detected by standard anatomic imaging sequences, DTI sequences, and proton MR spectroscopy varied considerably during the first 2 weeks after injury. The appearance of new areas of reduced diffusion simultaneous with the pseudonormalization of areas that had reduced diffusion at earlier times can result in an entirely different pattern of injury on diffusivity maps acquired at different time points. Awareness of these evolving patterns is essential if studies are performed and interpreted during this critical period of time.

Brain Diseases↗