Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MICROWAVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Comparison of effects of sublethal microwave radiation and conventional heating on the metabolic activity of Staphylococcus aureus.

This study was conducted in an attempt to characterize some of the effects of sublethal microwave radiation on cells of Staphylococcus aureus. Cultures were exposed to microwave radiation for 10, 20, 30, and 40 s. The effects of a conventional heat treatment were also compared by placing flasks containing cultures in a boiling water bath for the amount of time required to reach temperatures equivalent to those found in cultures exposed to microwave radiation. Control, microwave-treated, and conventionally heat-treated cultures were centrifuged, pellets were resuspended in distilled water, and the resulting suspensions were passed through a French pressure cell. Cell lysates and walls were then isolated and assayed for enzymatic activity. Thermonuclease production was also determined at various levels of exposure of cells to microwave radiation. Activities of malate and alpha-ketoglutarate dehydrogenases, cytochrome oxidase, and cytoplasmic adenosine triphosphatase were higher in microwave-treated cells than in control cells. Membrane adenosine triphosphatase, alkaline phosphatase, and lactate dehydrogenase activities were unaffected when cells were exposed to microwave radiation. The activity of glucose-6-phosphate dehydrogenase was decreased by exposure of cells to microwave radiation. In conventionally heated cells, activities of glucose-6-phosphate and malate dehydrogenases and cytoplasmic adenosine triphosphatase increased activities of alpha-ketoglutarate and lactate dehydrogenases decreased, and alkaline phosphatase activity remained unaffected. Increased levels of thermonuclease activity were observed when cells were exposed to microwave radiation for 10 or 20 s. Data indicate that microwave radiation affects S. aureus in a manner which cannot be explained solely by thermal effects.

Adenosine Triphosphatases↗

Microwave drying of granules containing a moisture-sensitive drug: a promising alternative to fluid bed and hot air oven drying.

The impact of microwave drying and binders (copolyvidone and povidone) on the degradation of acetylsalicylic acid (ASA) and physical properties of granules were compared with conventional drying methods. Moist granules containing ASA were prepared using a high shear granulator and dried with hot air oven, fluid bed or microwave (static or dynamic bed) dryers. Percent ASA degradation, size and size distribution, friability and flow properties of the granules were determined. Granules dried with the dynamic bed microwave dryer showed the least amount of ASA degradation, followed by fluid bed dryer, static bed microwave oven and hot air oven. The use of microwave drying with a static granular bed adversely affected ASA degradation and drying capability. Dynamic bed microwave dryer had the highest drying capability followed by fluid bed, static bed microwave dryer and conventional hot air oven. The intensity of microwave did not affect ASA degradation, size distribution, friability and flow properties of the granules. Mixing/agitating of granules during drying affected the granular physical properties studied. Copolyvidone resulted in lower amount of granular residual moisture content and ASA degradation on storage than povidone, especially for static bed microwave drying. In conclusion, microwave drying technology has been shown to be a promising alternative for drying granules containing a moisture-sensitive drug.

Air↗

Microwaves in the laboratory: effective decontamination.

OBJECTIVE: We hypothesize that microwave irradiation of certain contaminated materials typically used in a clinical laboratory or a home healthcare setting could produce efficient and effective sterilization when compared to standard autoclave methods. DESIGN: A standard household carousel microwave oven unit used at the High setting was employed to expose certain materials that had been contaminated with either bacteria or yeast to microwaves for specific intervals of time. Following each time interval, materials were checked for effectiveness of decontamination using standard culture techniques and colony counting. Additionally, powdered media was prepared and microwave irradiated for specific times. The media was then poured into plates and checked for microbial contamination; another set of plates was examined to determine the ability of the irradiated media to support bacterial growth. SETTING: This study was carried out at Texas Tech University Health Sciences Center in Lubbock TX. MAIN OUTCOME MEASURE: Standard culture and colony counting techniques were used to determine the efficacy of microwave sterilization. RESULTS: The study indicated that microwave irradiation provided effective and efficient sterilization of all materials tested. Of the bacteria studied, only E. coli survived beyond 30 seconds of microwave exposure. Yeast did not survive beyond 15 seconds of microwave exposure. Swabs and gauze contaminated with bacteria or yeast were completely sterilized after 30 seconds. After three minutes in the microwave oven, powdered, prepared media was free of contamination while able to support growth when inoculated with S. aureus. CONCLUSION: We conclude that a household carousel microwave oven unit can provide fast, effective sterilization of certain contaminated materials typically used in a clinical laboratory, student laboratory, or home healthcare setting.

Bacteria↗

Methods of microwave fixation for microscopy. A review of research and clinical applications: 1970-1992.

Microwave fixation methods are important because excellent preservation of both cell structure and antigenicity can be attained several orders of magnitude faster than by routine chemical fixation methods. Fast and ultrafast microwave fixation have yielded significant logistic advantages over another fast fixation approach-rapid freezing at liquid helium temperatures. For example, specimens used for microwave fixation can be as large as 1 cm3 and cells can remain in suspension. We review in detail both qualitative and quantitative morphologic results obtained by using microwave fixation in sample preparation. We provide tables of biological molecules that are preserved in a variety of human and animal tissues by various microwave fixation methods for histochemistry, immunohistochemistry, cytochemistry, immunocytochemistry, and affinity labelling studies. Limitations of large cavity (e.g., household) microwave ovens often result in irreproducible fixation results. We present calibration and standardization protocols for microwave fixation in large cavity microwave ovens that emphasize a) localization of oven hot spots (i.e., high power) using a neon bulb array, b) magnetron warm-up, c) the use of a water load, d) the use of an agar-saline-Giemsa model to predict the uniformity of irradiation in small samples, e) the use of specimen containers with one dimension less than 1.5 cm, and f) fast specimen handling to prevent conductive heating artifacts after irradiation. Although microwave ovens are commonplace their unique applications in the laboratory environment require special safety considerations, which are reviewed. Advances in microwave technology are providing new means to study the structure-function relationships of cellular and biochemical activities.

Animals↗

Thermal and metabolic responsiveness of Japanese quail embryos following periodic exposure to 2,450 MHz microwaves.

Two studies were performed to determine if repeated exposure of the avian egg to microwaves can alter metabolism, temperature, and growth rate of embryos. Another aim was to supplement conventional heating with microwave heating and provide an optimal temperature for growth. Japanese quail (Coturnix coturnix japonica) eggs were exposed from day 1 through 15 of incubation (8 h/day) to sham or microwave (2,450 MHz) irradiation. Microwave exposures were at two power densities, 5 or 20 mW/cm2, and at three ambient temperatures (Tas), 30.0, 33.1, or 35.4 degrees C. Specific absorption rates for unincubated and 15-day-old incubated eggs were, respectively, 0.76 and 0.66 W kg-1 mW-1 cm-2 (i.e., 3.8 and 3.3 W/kg at 5 mW/cm2 and 15.2 and 13.2 W/kg at 20 mW/cm2). Eggs were concurrently sham exposed at each of five Tas, ranging from 27.9 to 37.5 degrees C. Tests were conducted during the 16th day of incubation (i.e., 1 day post-treatment), in the absence of microwaves, to determine metabolic rate of embryos and internal and external egg temperatures at different Tas. Repeated exposures to microwaves at 5 and 20 mW/cm2 at the same Ta (30 degrees C) increased wet-embryo mass on the 16th day by an average, respectively, of 9% and 61% when compared with predicted masses for embryos exposed at the same Ta in the absence of microwave radiation. There was no reliable indication, from post-treatment tests and comparisons with control embryos of similar mass, that repeated exposure to microwave radiation resulted in abnormal physiological development. Microwave radiation can be used to increase egg temperature and embryonic growth rate at Tas below normal incubation level without altering basic metabolic and thermal characteristics of the developing bird.

Adaptation, Physiological↗

Comparison of rat retinal fixation techniques: chemical fixation and microwave irradiation.

In histological studies using retinas, eyes are commonly fixed with aldehyde derivatives administered by immersion or perfusion. However, the histology of rat retinas chemically fixed as a whole eye is typically inferior to the histology of retinas that are immediately fixed after acute dissection from the rest of the eye. Chemical fixation without dissection often results in neuronal swelling resembling excitotoxic damage induced by ischemia because the retina is protected by the sclera and is thus poorly accessible to immersion or perfusion fixation techniques. In order for the acute dissection technique to work properly, it must be completed in a timely manner, which may be difficult under some circumstances. Microwave irradiation is an alternative method for fixing tissues that are inaccessable to chemicals. We examined the effectiveness of microwave irradiation of the whole eye as a substitute for acute retinal dissection. To study the feasibility of microwave methods, we compared retinal morphology using microwave irradiation to morphology using conventional immersion fixation methods. Eyes were removed from rats, placed in a container with 2 or 20 ml artificial cerebrospinal fluid (aCSF) and irradiated with a household microwave oven. For morphological comparison, control eyes were immersed in a chemical fixative containing 1% paraformaldehyde and 1.5% glutaraldehyde. All eyes were embedded in araldite for evaluation by light microscopy. Retinal segments acutely isolated before immersion fixation revealed intact histology whereas retinal segments exposed to 60 min of simulated ischemia showed severe neuronal degeneration. Using an immersion technique, the retinas of chemically fixed whole eyes showed neuronal swelling similar to excitotoxic ischemic damage, suggesting that conventional immersion methods provide poor whole eye fixation. The neuronal degeneration observed with conventional immersion fixation was not found in retinas of whole eyes fixed with 20 sec of microwave irradiation. During microwave irradiation the temperature in the bathing aCSF rose to 55-72 degrees C. In some eyes, overcooking produced chromatin clumping and a small loss of contrast in staining. Although nuclear clumping and diminished staining occasionally result from overcooking, ischemic damage is well controlled with microwave fixation of enucleated eyes. When the optimal conditions are defined, microwave fixation may be preferable for retinal histology if chemical fixation following acute dissection is not feasible.

Animals↗

Microwave applications in neuromorphology and neurochemistry: safety precautions and techniques.

In science, the introduction of a new method is never easy, not even if it concerns the use of a simple microwave oven. Most scientists do not realize the numerous applications of microwave techniques. This paper gives a broad overview of the application of microwave techniques in neuromorphology and neurochemistry, starting with a historical overview ranging from the introduction of microwave techniques as a scientific method in the 1970s to present. Organizations and publication rules are highlighted in the next part. The effect of microwave irradiation is discussed in two sections relating to microwave effects on the whole organism and on the neuron. The main body of the paper discusses the application of microwave techniques in the fields of neuromorphology and neuropathology. The paper then presents aspects of microwave irradiation as applied to ELISA techniques. In addition, cell fusion and cell reproduction under microwave irradiation are discussed.

Animals↗

Cell replication rates and processes concerning antibody production in vitro are not influenced by 2.45-GHz microwaves at physiologically normal temperatures.

Several contradictory papers concerning the effects of microwaves on living organisms and on in vitro cell suspensions have been published through the years. These papers are difficult to interpret, because temperature measurement data are often lacking. Reliable temperature measurements are important, because they enable one to determine whether the observed microwave effects are thermal or nonthermal. Therefore, a method was developed to investigate microwave effects on cellular processes, in which the temperature was precisely monitored during microwave treatment using a fiberoptic thermometer. This method involved the processes required for in vitro production of monoclonal antibodies. Monoclonal antibodies are vital ingredients in (microwave-stimulated) immunostaining techniques and ELISAs, which have become important techniques in neuroscience. The effects of 2.45-GHz microwaves on mouse myeloma and (neural) hybridoma cell replication rates and on antibody production were investigated. In addition, the effects on the cell fusion abilities of spleen lymphocytes and myeloma cells and on in vitro immunization were studied. The results of this study show no effects of microwaves on either of the processes mentioned using exposure times up to 5 h a day at a physiologically normal temperature of 37 degrees C. It was concluded that the effects of 2.45-GHz microwaves detected at higher temperatures are thermal effects and that no indications for nonthermal 2.45-GHz microwave effects exist under the exposure conditions used in the present study.

Animals↗

Effects of low-level microwave irradiation on amphetamine hyperthermia are blockable by naloxone and classically conditionable.

In a series of experiments, we investigated the effects of pulsed low-level microwave irradiation on amphetamine-induced hyperthermia in the rat. Rats were irradiated in a 2,450-MHz cylindrical waveguide exposure system at 1 mW/cm2, 2 mus pulses, 500 pps, average SAR of 0.6 W/kg. Acute (45 min) exposure to microwaves attenuated amphetamine-induced hyperthermia. This effect was blocked by pretreatment of the animals with the narcotic antagonist naloxone. In another experiment, rats were subjected to ten daily sessions of microwave exposure (45 min/session). On day 11, amphetamine-induced hyperthermia was studied in the animals immediately after a session of either microwave or sham exposure. Similar to the acute effect, amphetamine-induced hyperthermia was attenuated in rats irradiated with microwaves (unconditioned effect). In the sham-irradiated animals we observed a potentiation of the amphetamine-induced hyperthermia, which was a conditioned effect of microwaves. Thus, the conditioned effect (potentiation) was opposite in direction to the unconditioned effect (attenuation). No tolerance developed to the unconditioned effect after subchronic exposure. Furthermore, both conditioned and unconditioned effects of microwaves on amphetamine-induced hyperthermia could be blocked by treatment with naloxone. These data suggest that microwave irradiation may activate endogenous opioids, which in turn alter the actions of psychoactive drugs, and the effect of microwaves on drug action can be classically conditioned.

Amphetamine↗

Acceleration of the development of benzopyrene-induced skin cancer in mice by microwave radiation.

Development and growth of skin cancer may be affected by various physical and chemical factors present in human environment. Of these factors electromagnetic radiation of radio- and microwave spectra are among the most common. In the present study Balb/c mice were exposed to chemical carcinogen, 3,4-benzopyrene, painted on the skin every 2nd day for a total of 6 months, and simultaneously irradiated with athermal (5 mW/cm2) or subthermal (15 mW/cm2) doses of 2,450 MHz microwaves. The other group of animals was preirradiated with microwaves at 10 mW/cm2 power level for 1, 2, or 3 months and then treated with benzopyrene, as above. Control mice were exposed for 6 months to benzopyrene, resulting in the development of baso- or spinocellular skin carcinoma within approximately 9 months, and sham-irradiated with microwaves. The growth of the tumour was assessed according to a self-designed 7-range macroscopic scale, supported by microscopical examinations of skin sections. All protocols of microwave irradiations resulted in a significant acceleration of the development of benzopyrene-induced skin cancer and in shortening of life span of the tumour-bearing hosts. This effect seemed to be dose-dependent since subthermal doses (15 mV/cm2) and longer (3 months) expositions to microwaves were more efficient as compared to athermal doses (5 mW/cm2) and shorter preirradiations. In addition, low-level, long-lasting exposure to microwaves led to a marked suppression of delayed hypersensitivity of mice treated with benzopyrene, as assessed by their reactivity to dinitrofluorbenzene (DNFB). It is suggested that the observed co-carcinogenic effect of microwave radiation may, at least in part, result from the inhibitory action of microwaves on cellular immune reactions of exposed animals.

Animals↗

Effects of whole body microwave exposure on the rat brain contents of biogenic amines.

The effects of whole body microwave exposure on the central nervous system (CNS) of the rat were investigated. Rats weighing from 250 to 320 g were exposed for 1 h to whole body microwave with a frequency of 2450 MHz at power densities of 5 and 10 mW.cm-2 at an ambient temperature of 21-23 degrees C. The rectal temperatures of the rats were measured just before and after microwave exposure and mono-amines and their metabolites in various discrete brain regions were determined after microwave exposure. Microwave exposure at power densities of 5 and 10 mW.cm-2 increased the mean rectal temperature by 2.3 degrees C and 3.4 degrees C, respectively. The noradrenaline content in the hypothalamus was significantly reduced after microwave exposure at a power density of 10 mW.cm-2. There were no differences in the dopamine (DA) content of any region of the brain between microwave exposed rats and control rats. The dihydroxyphenyl acetic acid (DOPAC) content, the main metabolite of DA, was significantly increased in the pons plus medulla oblongata only at a power density of 10 mW.cm-2. The DA turnover rates, the DOPAC:DA ratio, in the striatum and cerebral cortex were significantly increased only at a power density of 10 mW.cm-2. The serotonin (5-hydroxytryptamine, 5-HT) content in all regions of the brain of microwave exposed rats was not different from that of the control rats. The 5-hydroxyindoleacetic acid (5-HIAA) content in the cerebral cortex of microwave exposed rats was significantly increased at power densities of 5 and 10 mW.cm-2.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Magnetron-based inline microwave fluid warmer.

OBJECTIVE: To develop an in-line microwave fluid warming system that eliminates the difficulties of uneven heating that are characteristic of batch-mode microwave fluid warmers. METHODS: Using a commercial microwave oven, we developed a method for warming fluid as it flowed through tubing along a defined path in the oven's cavity. Algorithms utilizing either proportional or adaptive control were used to control microwave heating cycles by varying the heating pulse-width during 3-second epochs. Methods of fluid entry and exit were devised to minimize microwave leakage. Heating performance was tested using icewater at multiple flow rates from 18 mL/min to 105 mL/min. RESULTS: In all warming tests, the system achieved temperature control without exceeding the maximum temperature allowable based on American Association of Blood Banks requirements. The adaptive control maintained the set temperature, with peak-to-peak oscillations of 2 degrees C or less. Microwave leakage was below the commercially required limit for home microwave appliances. CONCLUSIONS: The combination of proportional and adaptive control is successful in controlling the permanent magnet magnetron microwave energy to heat the icewater tested. The in-line microwave warmer has the potential to become a successful medical fluid warmer. More study is needed to determine the stability of the control system under clinical conditions, and to evaluate its utility for warming blood.

Blood Transfusion↗

Disruption of erythrocytes distinguishes fixed cells/tissues from viable cells/tissues following microwave coagulation therapy.

Microwave coagulation therapy (MCT) has recently been applied to treat hepatic tumors. However, the histological changes in the liver following MCT have not been fully elucidated. A type of cell death known as microwave fixation has been reported in areas adjacent to the microwave irradiator electrodes, and these areas are without acid phosphatase (AcP) activity. Diagnosis of microwave-fixed tissue by hematoxylin and eosin (HE) staining is very difficult because morphology is well maintained for months. In an effort to clarify the histological changes and the mechanisms of microwave fixation, we performed HE staining, enzyme histochemistry for AcP, and electron microscopy in both rat and human liver samples after MCT. Although the microwave-fixed tissues maintained their structure on HE staining, membranes of microwave-fixed cells were seriously damaged and there were no apparent organelle structures in these cells on electron microscopy. Erythrocytes were also damaged in these tissues on both light and electron microscopy. The cause of microwave fixation is thought to be injury of the membrane, which is similar to coagulative necrosis. In conclusion, microwave fixation can be considered a type of coagulative necrosis without enzyme digestion. Disruption of erythrocytes on HE staining is an interesting and important diagnostic clue in distinguishing nonviable fixed tissues from viable tissues following MCT.

Acid Phosphatase↗

Low-level microwave irradiation and central cholinergic systems.

Our previous research showed that 45 min of exposure to low-level, pulsed microwaves (2450-MHz, 2-microseconds pulses, 500 pps, whole-body average specific absorption rate 0.6 W/kg) decreased sodium-dependent high-affinity choline uptake in the frontal cortex and hippocampus of the rat. The effects of microwaves on central cholinergic systems were further investigated in this study. Increases in choline uptake activity in the frontal cortex, hippocampus, and hypothalamus were observed after 20 min of acute microwave exposure, and tolerance to the effect of microwaves developed in the hypothalamus, but not in the frontal cortex and hippocampus, of rats subjected to ten daily 20-min exposure sessions. Furthermore, the effects of acute microwave irradiation on central choline uptake could be blocked by pretreating the animals before exposure with the narcotic antagonist naltrexone. In another series of experiments, rats were exposed to microwaves in ten daily sessions of either 20 or 45 min, and muscarinic cholinergic receptors in different regions of the brain were studied by 3H-QNB binding assay. Decreases in concentration of receptors occurred in the frontal cortex and hippocampus of rats subjected to ten 20-min microwave exposure sessions, whereas increase in receptor concentration occurred in the hippocampus of animals exposed to ten 45-min sessions. This study also investigated the effects of microwave exposure on learning in the radial-arm maze. Rats were trained in the maze to obtain food reinforcements immediately after 20 or 45 min of microwave exposure.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Beam shaping for microwave waveguide hyperthermia applicators.

PURPOSE: Hyperthermia treatments commonly use single element microwave waveguide applicators. The microwave beam patterns produced by these applicators are often non-uniform. As a result, hot spots are formed in the heated tissue and therapeutic temperatures are reached in only small areas of the treatment field. We have constructed new coupling boluses that improve the heating patterns of external microwave applicators. METHODS: The microwave beam transmitted through the bolus is modified by microwave absorbing saline/gelatin pads. The pads can be designed to result in a uniform heating pattern over a large area or alternatively, complex heating patterns can be generated for specific clinical applications. An analysis of the effect of bolus design parameters on microwave absorption patterns is presented. The heating patterns of the MA-100 and MA-120 microwave waveguide applicators have been measured in muscle and fat phantom materials with both the manufacturer's boluses and the new boluses. RESULTS: In the case of the MA-100, the area above the 70% heating level measured in a muscle phantom was increased by a factor of 2.3 by an absorbing pad bolus. Similarly, the heating area of the MA-120 was increased by a factor of 2.6 by an absorbing pad bolus. The boluses were tested in a clinical setting by measuring tissue temperature profiles in patients under different bolus arrangements. The area over which therapeutic temperature was achieved was increased considerably when the absorbing bolus was used. A second bolus was designed for the MA-120 to produce a ring heating pattern for the treatment of a breast cancer patient who had developed recurrences at the periphery of a skin graft. The heating pattern produced in a muscle phantom is compared with tissue temperature profiles measured during the hyperthermia treatment of this patient. CONCLUSIONS: Microwave absorbing filters using saline pads significantly improve the heating patterns of microwave waveguide hyperthermia applicators. This improvement was confirmed in clinical application where much greater areas of homogeneous heating were observed. The technology was extended to produce complex heating patterns for special clinical applications.

Breast Neoplasms↗

Removal of copper from industrial sludge by traditional and microwave acid extraction.

This work elucidates the removal of copper from industrial sludge by traditional and microwave acid extraction. The effects of acid concentration, extraction time, sludge particle size and solid/liquid (S/L) ratio on copper removal efficiency were evaluated. Leaching with more concentrated acid yielded greater copper content from the industrial sludge. The experimental findings reveal that the most economical traditional extraction conditions were the use of 1N sulfuric or nitric acid for 60 min at an S/L ratio of 1/20; however, at an S/L ratio of 1/6, the extraction time needed to achieve the same copper removal efficiency was increased to 36 h. Increasing the microwave power and reducing the S/L ratio increased the copper extraction efficiency and the effect in the larger S/L ratio system was more significant. A comparison of the results of microwave-assisted (microwave only) and microwave-enhanced (microwave with addition of active carbon) acid extraction demonstrated that under both conditions, S/L ratio=1/6 and 1/20; adding active carbon shortened the extraction time required to achieve 80% copper extraction efficiency from 20 to 10 min. These experimental results indicate that the most important factors that most strongly affected microwave acid extraction were the addition of a microwave absorber, the microwave power input and the S/L ratio. The sludge particle size did not significantly affect the copper extraction. The results reveal that sulfuric acid was an effective extractant and that the copper fraction in the extracted sludge shifted from being mostly bound to the Fe-Mn oxides and organic matter, to being mostly bound to organic matter and remaining as a residue during acid extraction.

Acids↗

Microwave-assisted immunostaining: a new approach yields fast and consistent results.

Advances in microwave technology permitted the development of new antigen labeling techniques. The recent microwave development of a true variable wattage unit designed for laboratory use and an apparatus for dampening standing wave radiation patterns have allowed investigators to better control the conditions within a microwave cavity. Thus, operating limits thought to be endemic to microwave-assisted protocols could be effectively mitigated. Standard protocols for histochemistry call for prolonged incubations and numerous rinses that add considerable time to the procedure. Here, we present microwave-assisted staining protocols for floating rat brain sections and cultured rat hippocampal cells. Acetylcholinesterase (ACHE) histochemistry and immunocytochemistry were conducted inside a specially designed and configured laboratory microwave oven. As a control additional tissue sections were stained on the bench and treated in the same manner as those in the microwave. Labeling was minimal in the control tissue, but specific, high contrast staining was present in the microwave group. Tissues were evenly stained with minimal background, and anatomical structures were easily detected. Also, the differences between lesioned and intact sides of the brain were obvious and agreed with previous observations. Microwave-assisted methods resulted in significantly shorter protocol times (approximately 10-fold) resulting in staining patterns of equal or superior quality to those obtained using conventional methods.

Acetylcholinesterase↗

Mechanisms of microwave irradiation involved in the destruction of fecal coliforms from biosolids.

Microwaves have been found to be effective in destructing pathogens in sewage sludge (biosolids) (75th Annual Water Environment Federation Conference, Chicago, September 29-October 2, 2002; Third World Water Congress, International Water Association, Melbourne, Australia, April 7-12, 2002). Mechanisms and roles of microwaves on fecal coliform destruction were investigated using bacterial viability tests, electron transport system (ETS) and beta-galactosidase activity assays, gel electrophoresis, and genomic deoxyribonucleic acid (DNA) optical density (OD) measurements with fecal coliforms isolated from biosolids. Bacterial viability tests demonstrated cell membrane damage as microwave irradiation intensity and temperature increased. Above 60+/-3 degrees C, viable cells were rarely found when pure fecal coliforms were irradiated with microwaves. ETS and beta-galactosidase activity assays revealed increased activity for externally heated samples due to fecal coliform growth but decreased activity for microwave-irradiated samples as temperature was increased from 20 degrees C to 57 degrees C, indicating other destruction mechanisms besides heating. Between 57 degrees C and 68 degrees C, microwave irradiation led to a more rapid decrease in activity than external heating by convection. Above 68 degrees C, bacterial activity almost ceased for both pretreatments. DNA bands in gel electrophoresis tests and OD of genomic DNA decreased more rapidly for microwave-irradiated samples than for externally heated samples, implying that microwaves disrupted DNA in fecal coliform cells at lower temperatures than external heating. Microwave irradiation of sludge appears to be a viable and economical method of destructing pathogens and generating environmentally safe sludge.

DNA, Bacterial↗