Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid-Liquid Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma.

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.

Antidiuretic Agents↗

Simultaneous determination of oxycodone and its major metabolite, noroxycodone, in human plasma by high-performance liquid chromatography.

Oxycodone (14-hydroxy-7,8-dihydrocodeinone) is a potent opioid receptor agonist. In the present study, a liquid-liquid extraction-based reversed-phase HPLC method with UV detection was validated and applied for the analysis of oxycodone and its major metabolite, noroxycodone, in human plasma. The analytes were separated using a mobile phase, consisting of acetonitrile and phosphate buffer (8:92, v/v) at a flow rate of 1 mL/min, and UV detection at 205 nm. The retention times for oxycodone, noroxycodone and codein (internal standard) were 14.7, 13.8 and 10.2 min, respectively. The validated quantitation range of the method was 2-100 ng/mL for oxycodone and 10-100 ng/mL for noroxycodone. The developed procedure was applied to assess the pharmacokinetics of oxycodone and its metabolite following administration of a single 20 mg oral dose of oxycodone hydrochloride to one healthy male volunteer.

Adult↗

Determination of rizatriptan in human plasma by liquid chromatographic-eletrospray tandem mass spectrometry: application to a pharmacokinetic study.

A sensitive liquid chromatographic-tandem mass spectrometry(LC-MS/MS) method was developed for the determination of rizatriptan in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax XDB C8 column (150 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an electrospray ionization interface. Zomitriptan was used as the internal standard. The method had a lower limit of quantitation of 50 pg/mL for rizatriptan, which showed more sensitivity and speed of analysis compared with reported methods. The within- and between-day precision was measured to be below 11.71% and accuracy between -5.87 and 0.86% for all quality control samples. This quantitation method was successfully applied to the evaluation of the pharmacokinetic profiles of rizatriptan after single oral administration of 5, 10 and 15 mg rizatriptan tablets to 10 healthy volunteers (five males and five females).

Calibration↗

Liquid chromatographic assay for the protease inhibitor atazanavir in plasma.

Atazanavir is the most recently introduced protease inhibitor for the suppression of the anti-human immunodeficiency virus. A sensitive and selective reversed-phase liquid chromatographic assay for this drug in human plasma has been developed and validated. Atazanavir was isolated from a 500 microL plasma sample using liquid-liquid extraction with dichloromethane. After evaporation and reconstitution of the extract the sample was analysed using liquid chromatography and ultraviolet detection at 280 nm. In the evaluated concentration range (44-4395 ng/mL atazanavir), intra-day precisions were < or =7% and inter-day precisions were < or =14%. Accuracies between 96 and 106% were found. The lower limit of quantification was 44 ng/mL with an intra-day precision of 7%, an inter-day precision of 14% and an accuracy of 87%. There was no interference from 32 tested potentially co-administrated drugs and metabolites. The usefulness of the assay was demonstrated for samples obtained from an HIV-infected patient treated with atazanavir.

Atazanavir Sulfate↗

Simultaneous quantitation of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide and celecoxib in plasma by high-performance liquid chromatography with UV detection.

A specific, accurate, precise and reproducible high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous quantitation of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide and celecoxib in human plasma. The method employed a simple liquid-liquid extraction of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide and celecoxib and internal standard (IS, DRF-4367) from human plasma (500 microL) into acetonitirile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). The chromatographic separation was achieved by gradient elution consisting of 0.05 M formic acid (pH 3)-acetonitrile-methanol-water at a flow rate of 1.0 mL/min. The eluate was monitored using an ultraviolet (UV) detector set at 235 nm. The ratio of peak area of each analyte to IS was used for quantification of plasma samples. Nominal retention times of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide, IS and celecoxib were 15.63, 17.20, 21.66, 24.95, 26.27, 30.24 and 32.22 min, respectively. The standard curve for etoricoxib, salicylic acid, valdecoxib, ketoprofen and celecoxib was linear (r2 > 0.999) in the concentration range 0.1-50 microg/mL and for nimesulide (r2 > 0.999) in the concentration range 0.5-50 microg/mL. Absolute recovery was >83% from human plasma for all the analytes and IS. The lower limit of quantification (LLOQ) of nimesulide was 0.5 microg/mL and for etoricoxib, salicylic acid, valdecoxib, ketoprofen and celecoxib the LLOQ was 0.1 microg/mL. The inter- and intra-day precisions in the measurement of QC samples, 0.1, 0.3, 15.0 and 40.0 microg/mL (for all analytes except nimesulide), were in the range 2.29-9.37% relative standard deviation (RSD) and 0.69-10.28% RSD, respectively. For nimesulide the inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.5, 1.5, 15.0 and 40.0 microg/mL, were in the range 3.21-7.37% RSD and 0.97-7.06% RSD, respectively. Accuracy in the measurement of QC samples for all analytes was in the range 91.03-106.38% of the nominal values. All analytes including IS were stable in the battery of stability studies, viz. bench top, autosampler and freeze-thaw cycles. Stability of all analytes was established for 21 days at -20 degrees C. The application of the assay in an oral pharmacokinetic study in rats co-administered with celecoxib and valdecoxib is described.

Animals↗

Analysis of five HMG-CoA reductase inhibitors-- atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin: pharmacological, pharmacokinetic and analytical overview and development of a new method for use in pharmaceutical formulations analysis and in vitro metabolism studies.

A specific, accurate, precise and reproducible high-performance liquid chromatographic (HPLC) method was developed and validated for the simultaneous quantitation of five 3-hydroxy-3-methyglutaryl coenzyme A (HMG-CoA) reductase inhibitors, viz. atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin, in pharmaceutical formulations and extended the application to in vitro metabolism studies of these statins. Ternary gradient elution at a flow rate of 1 mL/min was employed on an Intertisl ODS 3V column (4.6 x 250 mm, 5 microm) at ambient temperature. The mobile phase consisted of 0.01 m ammonium acetate (pH 5.0), acetonitrile and methanol. Theophylline was used as an internal standard (IS). The HMG-CoA reductase inhibitors and their metabolites were monitored at a wavelength of 237 nm. Drugs were found to be 89.6-105.6% of their label's claim in the pharmaceutical formulations. For in vitro metabolism studies the reaction mixtures were extracted with simple liquid-liquid extraction using ethyl acetate. Baseline separation of statins and their metabolites along with IS free from endogenous interferences was achieved. Nominal retention times of IS, atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin were 7.5, 17.2, 21.6, 28.5, 33.5 and 35.5 min, respectively. The proposed method is simple, selective and could be applicable for routine analysis of HMG-CoA reductase inhibitors in pharmaceutical preparations as well as in vitro metabolism studies.

Animals↗

Determination of the endocannabinoid anandamide in human plasma by high-performance liquid chromatography.

Anandamide (N-arachidonylethanolamine) is an endogenous cannabinoid receptor ligand that has been implicated in various physiological and pathophysiological functions. In the present study, a liquid-liquid extraction-based reversed-phase HPLC method with fluorometric detection was validated and applied for the analysis of anandamide in human plasma. Following derivatization with the fluorogenic reagent 4-(N,N-dimethylaminosulfonyl)-7-(N-chloroformylmethyl-N-methyl-amino)-2,1,3-benzoxadiazole (DBD-COCl), the analyte was separated using an acetonitrile-water gradient at a flow rate of 0.8 mL/min, and spectrophotometric detection at 560 nm with an excitation wavelength of 450 nm. The retention times for anandamide and R+-methanandamide (internal standard) were 27.1 and 30.7 min, respectively. The validated quantification range was 1-15 ng/mL. The developed procedure was applied to determine anandamide levels in human plasma following a 24 h incubation of human whole blood at 37 degrees C in the presence or absence of phenylmethylsulfonyl fluoride, an inhibitor of the anandamide-degrading enzyme fatty acid amide hydrolase. Anandamide levels determined under both conditions were within the validated concentration range with anandamide levels being 2.3-fold higher in plasma from PMSF-treated blood.

Arachidonic Acids↗

Screening for anabolic steroids in doping analysis by liquid chromatography/electrospray ion trap mass spectrometry.

A fast and selective LC/MS/MS method for the screening of four anabolic steroids in human urine has been developed and validated. Liquid-liquid extraction with diethyl ether was applied after enzymatic hydrolysis. Analyses were performed on an ion trap mass spectrometer equipped with electrospray ionisation. MS/MS was applied for all compounds. The analytical run time was 11 min. The LOD for all compounds varied between 1 and 10 ng/mL. Left-over A samples, which were declared positive by GC/MS for the presence of 3'-hydroxystanozolol, were assessed using the described method.

Anabolic Agents↗

Sensitive and rapid liquid chromatography/tandem mass spectrometry assay for the quantification of amlodipine in human plasma.

A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of amlodipine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase C(18) column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 409/238 for amlodipine and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 50-10,000 pg/mL for amlodipine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of amlodipine and the IS from spiked plasma samples were 74.7 +/- 4.6 and 72.1 +/- 2.0%, respectively. A run time of 1.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. The observed maximum plasma concentration (Cmax) of amlodipine (2.5 mg oral dose) was 1425 pg/mL, time to observed maximum plasma concentration (Tmax) was 8.1 h and elimination half-life (T(1/2)) was 50.1 h.

Adolescent↗

Quantitation of zopiclone and desmethylzopiclone in human plasma by high-performance liquid chromatography using fluorescence detection.

A simple, reliable HPLC method using fluorescence detection (excitation 307 and emission 483 nm) was developed and validated for simultaneous quantitation of zopiclone and its metabolite desmethylzopiclone in human plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (zaleplon) were separated using an isocratic mobile phase on a reversed-phase C18 column. The lower limit of quantitation was 3 ng/mL for zopiclone and 6 ng/mL for desmethylzopiclone with a relative standard deviation of less than 5%. A linear dynamic range of 3-300 ng/mL for zopiclone and of 6-500 ng/mL for desmethylzopiclone was established. This HPLC method was validated with between-batch precision of 1.7-4.2% and 3.2-7.5% for zopiclone and desmethylzopiclone respectively. The between-batch accuracy was 99.4-111.5% and 101.6-104.8% for zopiclone and desmethylzopiclone, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of zopiclone and desmethylzopiclone in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days' storage in a freezer. This validated method is simple and repeatable enough to be used in pharmacokinetic studies.

Azabicyclo Compounds↗

Determination of rosuvastatin in rat plasma by HPLC: Validation and its application to pharmacokinetic studies.

A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of rosuvastatin (RST), a novel, synthetic and potent HMG-CoA inhibitor in rat plasma. The assay procedure involved simple liquid-liquid extraction of RST and internal standard (IS, ketoprofen) from a small plasma volume directly into acetonitrile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). Mobile phase consisting of 0.05 m formic acid and acetonitrile (55:45, v/v) was used at a flow rate of 1.0 mL/min for the effective separation of RST and IS. The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 240 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of RST and IS were 8.6 and 12.5 min, respectively. The standard curve for RST was linear (r2 > 0.999) in the concentration range 0.02-10 microg/mL. Absolute recoveries of RST and IS were 85-110 and >100%, respectively, from rat plasma. The lower limit of quantification (LLOQ) of RST was 0.02 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.02, 0.06, 1.6 and 8.0 microg/mL, were in the range 7.24-12.43% relative standard deviation (RSD) and 2.28-10.23% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.05-112.17% of the spiked nominal values. Both analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. RST was found to be stable for a period of 30 days on storage at -80 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.

Animals↗

Quantification of granisetron in human plasma by liquid chromatography coupled to electrospray tandem mass spectrometry.

A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of granisetron in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 313/138 for granisetron and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for granisetron in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 5%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.

Chromatography, High Pressure Liquid↗

Determination of ligustilide in rat blood and tissues by capillary gas chromatography/mass spectrometry.

A gas chromatography/mass spectrometry (GC/MS) method was developed to study the pharmacokinetics of ligustilide following oral administration to rats. The method was used for the analysis of samples taken from rats. Biological samples were prepared by liquid-liquid extraction (LLE) using an n-hexane-ether (2:1) solvent mixture for a sample clean-up step and analyzed by GC/MS with a quadrupole MS detector in selected ion monitoring mode (m/z 190). The calibration curves were linear over the concentration range 0.172-8.60 microg/mL (r > 0.99) for blood samples and a different range (r > 0.99) for different tissue samples. The limit of detection (LOD) was 1.0 ng/mL or 1.0 ng/g (three times the signal-noise ratio). Within- and between-day precision expressed as the relative standard deviation (RSD) for the method was 1.58-3.88 and 2.99-4.91%, respectively. The recovery for all samples was >80%, except for liver samples (>70%). The main pharmacokinetic parameters obtained were: T(max) = 0.65 +/- 0.07 h, C(max) = 1.5 +/- 0.2 microg/mL, AUC = 34 +/- 6 h microg/mL and K(a) = 3.5 +/- 0.6/h. The experimental results showed that ligustilide was easily absorbed, but its elimination was slow, from 3 to 12 h after oral administration. The concentrations of ligustilide in rat cerebellum, cerebrum, spleen and kidney were higher than those in other organs.

4-Butyrolactone↗

Simultaneous quantification of atorvastatin and active metabolites in human plasma by liquid chromatography-tandem mass spectrometry using rosuvastatin as internal standard.

A simple, sensitive, selective and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of atorvastatin and its active metabolites ortho-hydroxyatorvastatin and para-hydroxyatorvastatin in human plasma using rosuvastatin as internal standard (IS). Following simple liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 559/440 for atorvastatin, m/z 575/466 for ortho-hydroxyatorvastatin, m/z 575/440 for para-hydroxyatorvastatin and m/z 482/258 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for atorvastatin and its two metabolites in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of atorvastatin, ortho-hydroxyatorvastatin, para-hydroxyatorvastatin and the IS from spiked plasma samples were 54.2 +/- 3.2, 50.1 +/- 3.8, 65.2 +/- 3.6 and 71.7 +/- 2.7%, respectively. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.

Atorvastatin↗

Development and validation of a sensitive quantification method for hematoporphyrin monomethyl ether in plasma using high-performance liquid chromatography with fluorescence detection.

A rapid, sensitive, precise and specific method for determination of hematoporphyrin monomethyl ether (HMME), a novel photodynamic therapy (PDT) drug, was developed and validated using high-performance liquid chromatography (HPLC) with fluorescence detection. HMME was isolated from the plasma by a single-step liquid-liquid extraction with ethyl acetate. The analyte and internal standard fluorescein were baseline separated on a Diamonsil C(18) analytical column (4.6 x 150 mm, 5 microm) and analyzed using a fluorescence detector with the excitation and emission wavelengths set at 395 and 613 nm, respectively. The method was linear in the concentration range 0.025-5 microg/mL with a lower limit of quantitation (LLOQ) of 10 ng/mL. The inter- and intra-day accuracies and precisions were all within 10% and the mean recoveries of HMME and fluorescein were 95 +/- 3.7 and 90 +/- 2.3%, respectively. The analyte was stable during all sample storage, preparation and analysis periods. This method was successfully applied to a pharmacokinetic study after a single-dose intravenous administration of HMME (5 mg/kg) to beagle dogs. This method was reproducible and sensitive enough for the pharmacokinetic study of HMME. Based on the results of the pharmacokinetic study, we suggest that a rather long light-avoiding time is essential for patients under HMME therapy.

Animals↗

HPLC quantification of the HIV-1 protease inhibitor saquinavir in brain and testis of mice.

A rapid, reliable HPLC method with UV detection (240 nm) was developed and validated for quantitation of saquinavir in mice brain and testis. Saquinavir and the internal standard were isolated from homogenized tissue matrices using liquid-liquid extraction procedure and were then analyzed using an isocratic mobile phase by reversed-phase liquid chromatography. The lower limit of quantification was 50 ng/g for both brain and testis. A linear dynamic range of 50-5000 ng/g for both brain and testis was established. This HPLC method was validated with between-batch precision of 0.5-4.4 and 1.5-5.5% for brain and testis, respectively. The between-batch accuracy was 94.7-105.9% and 97.5-105.0% for brain and testis, respectively. The present method was applied for tissue distribution studies of the novel drug delivery systems of saquinavir in mice.

Animals↗

A validated high-performance liquid chromatographic assay for determination of lumiracoxib in human plasma.

Lumiracoxib {2-[(2-fluoro-6-chlorophenyl)amino]-5-methyl-benzeneacetic acid} is a highly selective and potent cyclooxygenase-2 (COX-2) inhibitor, which is chemically distinct from other coxibs in that it contains a carboxylic group and is weakly acidic. In the present study, a liquid-liquid extraction-based reversed-phase HPLC method with UV detection was validated and applied for the analysis of lumiracoxib in human plasma. The analyte was separated on a reversed-phase column with acetonitrile and 0.05% trichloracetic acid in water (35:65, v/v) as mobile phase at a flow rate of 1 mL/min, and UV detection at 270 nm. The retention times for lumiracoxib and niflumic acid (internal standard) were 16.9 and 10.4 min, respectively. The validated quantitation range for lumiracoxib was 10-10,000 ng/mL. The developed procedure was applied to assess the pharmacokinetics of lumiracoxib following administration of a single oral 200 mg dose to a healthy male volunteer.

Chromatography, High Pressure Liquid↗

Quantification of zolpidem in human plasma by high-performance liquid chromatography with fluorescence detection.

A simple, reliable HPLC method with fluorescence detection (excitation 320 and emission 388 nm) was developed and validated for quantitation of zolpidem in human plasma. Following a single-step liquid-liquid extraction, the analyte and internal standard (quinine) were separated using an isocratic mobile phase on a reversed-phase C(18) column. The lower limit of quantitation was 1.8 ng/mL, with a relative standard deviation of less than 5%. A linear dynamic range of 1.8-288 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 1.7-4.8 and 1.2-2.3%, respectively. The between-batch and within-batch accuracy was 95.3-100.4 and 95.5-102.7%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of zolpidem in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is simple and repeatable enough to be used in pharmacokinetic studies.

Chromatography, High Pressure Liquid↗