Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “IFA”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Correlations between synthetic peptide-based enzyme immunoassays and immunofluorescence assay for detection of human herpesvirus 8 antibodies in different Argentine populations.

Human herpesvirus 8 (HHV-8) antibody tests vary in sensitivity and specificity, depending on the population tested and on the type of assay. In this study, we evaluated the sensitivity and specificity of two peptide enzyme immunoassays using a multiple antigenic peptide (PK8.1-MAP) or a chimeric peptide (PK8.1-orf65) as the antigens and determined the HHV-8 seroprevalence in different Argentine populations using an immunofluorescence assay (IFA) as reference. For analysis, when either or both of the peptide EIAs were positive, the specimen was considered positive (PEIA). We estimated the sensitivity and specificity of PEIA to be 97% using Kaposi's sarcoma (KS) patients and healthy individuals as positive and negative controls respectively. Then, we expanded the control groups to include IFA positive men who have sex with men (MSM) and IFA negative blood donors. The sensitivity decreased to 83% but specificity remained high at 98%. Concordance between PEIA and IFA was 77% for 1/40 IFA titers and increased to 90% for titers >or=1/160. Seroprevalences for HHV-8 performed in the HIV positive MSM were (IFA 73.1%; PEIA55.2%); heterosexuals (52.5%, 22.2%), which includes injecting drug users (IDU) (54.0%, 32.4%) and non-IDU (51.6%, 16.1%). The inclusion of non-KS HHV-8 IFA positive individuals to the positive controls may be a substantial improvement towards the realistic assessment of assay sensitivity. These peptide EIAs can be used for trends in populations with high probability of being HHV-8 infected and negative results should be confirmed by IFA. IFA test is still the most suitable test for populations with low probabilities of being infected.

Adult↗

Safety and efficacy of fire ant venom in the diagnosis of fire ant allergy.

Thirty-three adult patients who had had systemic allergic reactions to fire ant stings and 33 insect-nonallergic control subjects were skin tested with single lots of Solenopsis invicta (Sol i) fire ant venom (IFAV) and two commercially available imported fire ant whole body extracts (IFA WBEs). All three extracts were analyzed for protein concentration. Sol i II and Sol i III concentrations were each assayed by means of two ELISAs with complementary monoclonal antibodies, one species specific and one cross-reactive. Radioallergosorbent test (RAST) to IFAV and both IFA WBEs was performed on sera from all study subjects. Both IFA WBEs contained high concentrations of fire ant body proteins. Sol i II and III concentrations each varied twofold between the two IFA WBE preparations. Patients were generally more reactive to IFAV than IFA WBE by skin testing and RAST. IFAV RAST appeared to be a more sensitive assay than IFA WBE RAST. No adverse reactions occurred to skin testing with IFAV, but intradermal testing with higher concentrations of IFA WBE caused delayed large local reactions in 16 of 30 (53%) control subjects. These reactions were attributed to the large amounts of extraneous body proteins in IFA WBE. These results (1) demonstrate that skin testing with IFAV is safe, (2) indicate that IFAV is more potent than IFA WBE, and (3) suggest that IFAV may be the superior reagent for diagnosis of fire ant allergy.

Adult↗

Incomplete Freund's adjuvant reduces diabetes in the non-obese diabetic mouse.

As the study of type 1 diabetes moves towards preventive therapy, the role of adjuvants needs to be addressed. Incomplete Freund's adjuvant (IFA) is thought of as "immunologically inert" as, unlike complete FA (CFA), it has no components designed to provoke an immune response. We investigated the effect of IFA as an immunomodulator on the disease process leading to type 1 diabetes in the non-obese diabetic (NOD) mouse. 24 NOD mice were injected intradermally (i.d.) at 8 and 12 weeks of age with a 1:1 mixture of IFA and saline; 24 controls received saline alone. Splenocytes were tested against antigens thought to be involved in the disease process, namely insulin, a GAD peptide, a beta-casein peptide, a Glut-2 peptide and concanavalin A (ConA) as a non-specific antigen. In the IFA experiment diabetes incidence was 13% compared to 38% in the controls (p < 0.05). In vitro, splenocytes from IFA treated animals showed non-specific immunosuppression with ConA (p < 0.01), whereas the response to 1-casein and Glut-2 was raised in IFA treated animals with respect to controls. ELISA using supernatants from IFA treated animals, showed a typical Th2 cytokine pattern, whereas controls showed a Th1 pattern. In conclusion, IFA alone can reduce diabetes incidence in the NOD mouse apparently by modulating the immune response towards beta-cell related specific antigens. As IFA has been adopted as an adjuvant in preventive trials in the NOD mouse, this might have implications for the interpretation of previous and future results.

Animals↗

Screening for antinuclear antibodies by enzyme immunoassay.

Indirect fluorescent antibody (IFA) ia most widely used method in clin clinical laboratories to screen for autoantibodies against a wide variety of nuclear antigens. Recently, a number of antinuclear antibody (ANA) enzyme immunoassay (EIA) screens have become commercially available and claim to be an alternative method to screen for ANAs. Given the subjectivity of technical interpretation of IFA and the high number of ANA negative samples, a suitable EIA method for ANA screening would be beneficial to clinical laboratories with large samples volumes. Five ANA EIA screens were compared (Elias, Helix, Sanofi, TheraTest and Zeus) to IFA using a human epithelial cell line (HEp-2). Sera from 601 patients submitted to our reference laboratory for autoimmune testing, and from 202 normal healthy blood donors, were included in this study. Samples with discordant results between IFA and EIA were further analyzed using single antigen EIAs for SSA, SSB, Sm, RNP, Scl-70, histones, dsDNA, and ssDNA. Analyses were based on clinically significant IFA titers of > or equal to 1:160 as positive and <1:40 as negative. When compared to IFA, agreement, sensitivity and specificity for each ANA EIA screen were as follows: Elias: 87.0%, 69.5% and 97.9%; Helix: 94.6%, 90.2%, and 97.3%; Sanofi: 95.0%, 93.7%, and 95.9%; TheraTest: 95.3%, 97.7%, and 93.5%; Zeus: 87.1%, 96.2%, and 81.4%, respectively. In conclusion, screening for ANAs by EIA using several commercial assays was both sensitive and specific when compared to IFA. Moreover, the EIA is objective and much less labor intensive when screening a large number of clinical specimens. None of the EIAs were 100% sensitive and, thus, may fail to detect a few of the nonspecific ANAs that demonstrate atypical as well as classical IFA patterns. The advantages of employing these nonsubjective assays to screen out the vast majority of ANA negative sera is clear. The authors still recommend confirming titers and patterns of sera with positive EIA screens using classical IFA methods employing HEp-2 cells.

Antibodies, Antinuclear↗

Novel immunofluorescence assay using recombinant nucleocapsid-spike fusion protein as antigen to detect antibodies against severe acute respiratory syndrome coronavirus.

Severe acute respiratory syndrome (SARS) is caused by a novel and highly infectious virus named SARS coronavirus (SARS-CoV). Among the serological tests currently available for the detection of SARS-CoV, a whole-virus-based immunofluorescence assay (IFA) was considered one of the most sensitive assays and served as a "gold standard" during the SARS epidemic in Singapore in 2003. However, the need to manipulate live SARS-CoV in the traditional IFA limits its wide application due to the requirement for a biosafety level 3 laboratory and the risk of laboratory infection. Previously, we have identified two immunodominant epitopes, named N195 and Sc, in the two major structural proteins, the N and S proteins, of SARS-CoV (Q. He, K. H. Chong, H. H. Chng, B. Leung, A. E. Ling, T. Wei, S. W. Chan, E. E. Ooi, and J. Kwang, Clin. Diagn. Lab. Immunol., 11:417-422, 2004; L. Lu, I. Manopo, B. P. Leung, H. H. Chng, A. E. Ling, L. L. Chee, E. E. Ooi, S. W. Chan, and J. Kwang, J. Clin. Microbiol. 42:1570-1576, 2004). In the present study, the N195-Sc fusion protein was highly expressed in insect (Sf9) cells infected with a recombinant baculovirus bearing the hybrid gene under the control of a polyhedrin promoter. An IFA based on Sf9 cells producing the fusion protein was standardized with 23 serum samples from patients with SARS, 20 serum samples from patients with autoimmune diseases, and 43 serum samples from healthy blood donors. The detection rates were comparable to those obtained with a commercial SARS-CoV IFA kit (EUROIMMUN, Gross Groenau, Germany) and a conventional IFA performed at the Singapore General Hospital. Our data showed that the newly developed IFA could detect SARS-CoV in 22 of the 23 SARS-CoV-positive serum samples and gave no false-positive results when the sera from patients with autoimmune diseases and healthy individuals were tested. The detection rate was identical to those of the two whole-virus-based IFAs. Thus, the novel N-S fusion antigen-based IFA could be an attractive alternative to present whole-virus-based IFAs for the diagnosis of SARS-CoV infection.

Animals↗

Inclusion fluorescent-antibody test as a screening assay for detection of antibodies to Chlamydia pneumoniae.

A study was conducted to determine the ability of the inclusion immunofluorescence assay (inclusion IFA) to act as a screening test to detect samples with antibodies to Chlamydia pneumoniae; microimmunofluorescence (MIF) was used as the "gold standard." In addition, the inclusion IFA was compared using HEp-2 cells infected with either C. pneumoniae CM-1 or Chlamydia trachomatis serovar E. A total of 331 serum samples representing a range of MIF titers were evaluated. The sensitivities of the inclusion IFA for detecting samples with C. pneumoniae MIF titers of > or = 16 were 96.9 and 74.8% with C. pneumoniae- and C. trachomatis-infected cells, respectively. For samples with an elevated C. pneumoniae MIF titer of > or = 512, the sensitivities of the C. pneumoniae- and C. trachomatis-based inclusion IFA were 97.0 and 8.8%, respectively. These results suggest that the inclusion IFA is not a genus-specific test, as evidenced by the failure of the C. trachomatis-infected cells to detect a significant number of samples with C. pneumoniae antibodies. Samples that had elevated C. pneumoniae inclusion IFA and MIF titers but that were found negative (titer, <16) by the C. trachomatis inclusion IFA were further tested by an in vitro neutralization assay for functional antibodies that might not have been detected by the serological assays. The in vitro neutralization results corroborated the serological results in that all seven sera tested had a neutralization titer for C. pneumoniae (range, 20 to 225), while all but one failed to have any effect on the infectivity of C. trachomatis serovar E. While the C. pneumoniae inclusion IFA had a high sensitivity for detecting chlamydial antibodies, depending on whether it was used as a screening test for detecting samples with low (> or = 16) or elevated (> or = 512) MIF titers, its specificity ranged from 53.4 to 77.1%. In conclusion, the inclusion IFA with C. pneumoniae-infected cells was best suited as a sensitive screening test for identifying specimens with elevated MIF titers (those associated with a possible acute infection with C. pneumoniae).

Adult↗

Advantages of a human immunodeficiency virus type 1 (HIV-1) persistently infected HeLa T4+ cell line for HIV-1 indirect immunofluorescence serology.

A HeLa T4+ cell line persistently infected with human immunodeficiency virus type 1 (HIV-1) was used in an indirect immunofluorescent antibody assay (IFA) system to explore its potential suitability as an alternative source of viral antigen for confirmatory IFA in HIV serology. In a study of 121 serum samples chosen because they were reactive on repeat examination by enzyme immunoassay but nonspecific by IFA by using HIV-1-infected H9 cells (H9 IFA) or gave discrepant results by enzyme immunoassay and H9 IFA, the specificity and sensitivity of the HeLa T4+ IFA were comparable to those of Western blot (immunoblot), and identification of the true positive samples among these discrepant or nonspecific samples by HeLa T4+ IFA was approximately twice that by H9 IFA. The primary advantages of using the HeLa cell line rather than lymphoid cell lines in IFA are that cells can be grown as a monolayer and that the individual cells are much larger. The cell membrane, cytoplasm, and nucleus are easily discernible; this allows specific and nonspecific staining to be distinguished. At least eight different nonspecific nuclear and cytoplasmic staining patterns were identified in this study by using T4+ cells.

Evaluation Studies as Topic↗

Western blot analysis of sera reactive to human monocytic ehrlichiosis and human granulocytic ehrlichiosis agents.

Laboratory diagnosis of human ehrlichioses is routinely made by an indirect immunofluorescence assay (IFA) using cultured ehrlichia-infected whole cells as antigen. Concern has been raised that incorrect diagnoses of human monocytic ehrlichiosis (HME) or human granulocytic ehrlichiosis (HGE) may be made on the basis of serologic cross-reactivity between Ehrlichia chaffeensis and the agent of HGE. The present study examined whether two recombinant major outer membrane proteins, rP30 and rP44, that were previously shown to be sensitive and specific serodiagnostic antigens for HME and HGE, respectively, could be used to discriminate IFA dually reacting sera. Thirteen dually IFA-reactive sera, three sera that were IFA positive only with E. chaffeensis, and three sera that were IFA positive only with the HGE agent were examined by Western immunoblot analysis using purified whole organisms and recombinant proteins as antigens. All 16 E. chaffeensis IFA-positive sera reacted with rP30. However, none of these sera reacted with rP44, regardless of IFA reactivity with the HGE agent. The three HGE-agent-only IFA-positive sera reacted only with rP44, not with rP30. Western immunoblotting using purified E. chaffeensis and the HGE agent as antigens suggested that heat shock and other proteins, but not major outer membrane proteins, cross-react between the two organisms. Therefore, Western immunoblot analysis using rP44 and rP30 may be useful in discriminating dually HME and HGE IFA-reactive sera.

Antibodies, Bacterial↗

A rapid, quantitative immunofunctional assay for measuring human leptin.

BACKGROUND: We have developed a rapid, sensitive and quantitative in vitro assay for leptin based upon its ability to bind to the soluble extracellular domain of the leptin receptor (sOB-R). Such an assay is theoretically capable of differentiating between physiologically active leptin molecules from those with modified, either enhanced or reduced, binding activity. METHODS: A preparation of sOB-R was immobilized to capture leptin from serum samples or standards. Anti-leptin antibodies that had been raised in rabbits were added in a second incubation step to identify leptin molecules bound to sOB-R. Signal detection was performed in a third incubation step by anti-rabbit IgG labeled with peroxidase. The immunofunctional assay (IFA) was clinically validated by the comparison of leptin levels in adolescents (n = 41, age range 9-18 years, BMI range 13.4-33.8 kg/m(2) and adults (n = 80, age range 18-77 years, BMI range 16.4-54.7 kg/m(2) measured using the IFA with data of an in-house RIA performed with the same standards and leptin antibodies. RESULTS: The functional sensitivity of the IFA was 0.4 ng/ml and comparable to the data of the RIA. Intra- and interassay coefficients of variation were below 12.5 % in both methods. Leptin levels correlated well with the BMI of the subjects studied (r = 0.70 for RIA, r = 0.72 for IFA; p < 0.0001) as well as between IFA (y) and RIA (x) (y = x -1.31 ng/ml; r = 0.97, p < 0.0001). The median of the quotient between IFA and RIA levels was 0.86 (quartile range 0.60-1.10) for all samples. CONCLUSIONS: So far, only at the most minor differences between leptin measurements using the newly developed IFA and those using a conventional RIA have been detected. Additional studies using the IFA method are required to investigate whether or not discrepant results with the IFA will be seen in various states of relative leptin resistance and whether or not such differences are of biological relevance.

Adolescent↗

Method for differentiation of nonspecific from specfic toxoplasma IgM fluorescent antibodies in patients with rheumatoid factor.

In a study performed to define the prevalence of false positive toxoplasma IgM-IFA test results in sera containing RF, 8 (19.5%) of 41 sera which were positive for RF were positive in the toxoplasma DT and conventional toxoplasma IFA test. Three of these eight were also positive in the toxoplasma IgM-IFA test and in two, the results were considered to be false positives. Of the 33 sera remaining which were positive for RF but negative in both the DT and conventional IFA test, three were positive in the toxoplasma IgM-IFA test. Of 51 sera from patients with suspected rheumatoid arthritis or other collagen vascular disorders, all of which were negative when tested for RF, none was positive for toxoplasma IgM antibodies in the IgM-IFA test. Sera from 15 adults with the acute lymphadenopathic form of toxoplasmosis and 13 infants with congenital toxoplasmosis were tested for the presence of RF. Whereas none of the sera from the acquired cases had demonstrable RF, two of the congenital cases had RF, and their titers were both 1:320. False positive IgM-IFA test results became negative after treatment of sera with heat-aggregated IgG. In contrast, IgM-IFA test titers in cases of acute congenital or acquired toxoplasmosis were unaffected by this treatment. Thus, treatment with heat-aggregated IgG can be used to differentiate false positive IgM-IFA test titers due to RF from those due to specific IgM toxoplasma antibody.

Agglutination Tests↗

[Comparative study on antibody levels of vaccination group and control group after 4 years of immunized with type B inactivated vaccine against hemorrhagic fever with renal syndrome].

OBJECTIVE: To compare the antibody level of vaccine group and control group in a randomized, controlled trial of type B inactivated vaccine against hemorrhagic fever with renal syndrome(HFRS) in Jiande County of Zhejiang Province and to find out if there is enhancement of subclinical infection about type B inactivated vaccine against HFRS. METHODS: The number of sera collected (July 1994-July 1998) in vaccine group immunized type B inactivated vaccine against HFRS and control group were 305 and 283 persons in Jiande County respectively, and indirect immunofluorescent antibody method(IFAT) was used for testing the titer of HFRS IgG in sera. The cut-off values were determined on IFA titer of the second sera in control group with positive and negative IFA before vaccine was given respectively, and the subclinical infection of positive and negative IFA of the first sera in vaccine group was evaluated. RESULTS: When taking different cut-off values of subclinical infection, there were no statistical differences in HFRS IFA positive rates between vaccine group and control group of positive IFA in the first sera. In vaccine group and control group of negative IFA before vaccine given, also the IFA positive rates were not statistically different in these groups. There were no statistical differences of IFA GMT and IFA sero-negative rate between vaccine group and control group. CONCLUSIONS: The investigation showed there was no statistical difference in antibody level between vaccine group and control group, so there could not be enhancement of subclinical infection of vaccine group receiving type B inactivated vaccine against HFRS.

Adolescent↗

Evaluation of agar gel immunodiffusion and indirect fluorescent antibody assays as supplemental tests for dourine in equids.

The agar gel immunodiffusion (AGID) and indirect fluorescent antibody (IFA) assays were evaluated as supplemental tests to the complement-fixation (CF) test, the official US importation certification test for dourine in equids. The American stabilate (n = 10 animals) or the Canadian stabilate (n = 6 animals) of Trypanosoma equiperdum cultured in rat blood was administered by catheterization and infusion in the urogenital tract of 16 equids. To assess parasitemia and serologic responses by use of the CF, AGID, and IFA tests, a total of 787 serum and blood samples were obtained from equids before exposure and 3 times a week after exposure to T equiperdum. Results of the IFA and AGID tests were compared with the CF test results. The disease was diagnosed earlier by the IFA test than by the AGID test, regardless of antigen preparation or exposure group. The mean number of days between exposure and positive result by the CF and IFA tests was the same when either homologous or heterologous antigen was used in the IFA test. In general, the IFA test was more sensitive than the AGID test in diagnosing dourine, regardless of the antigen preparation used in the test or exposure group. Differences in test specificity were observed among both groups of exposed equids when either antigen was used (P < 0.05). The AGID test, using the American antigen, was more specific than the IFA test for sera from both groups of equids. When the Canadian antigen was used, the IFA test was a more specific test than the AGID test (P < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Agar↗

Down-regulation of Th1-mediated pathology in experimental arthritis by stimulation of the Th2 arm of the immune response.

OBJECTIVE: To assess whether systemic administration of recombinant interferon-gamma (rIFN gamma), a proinflammatory cytokine that influences the differentiation of naive T cells into Th1 cells, promotes the induction of arthritis in DBA/1 mice immunized with type II collagen (CII) in Freund's incomplete adjuvant (IFA) and to determine the antiarthritic effect of treatment with CII in IFA. METHODS: DBA/1 mice were immunized with CII in IFA and injected intraperitoneally with rIFN gamma (8,000 units/mouse/day) or with recombinant interleukin-12 (rIL-12; 100 ng/mouse/day). In another experiment, mice were immunized with CII in Freund's complete adjuvant (CFA) and treated with a single dose of CII in IFA on the day of immunization or on the day of disease onset. Mice were monitored to assess the effect of the treatment on the severity of disease. Th1/Th2 cytokines and anti-CII antibodies were measured by enzyme-linked immunosorbent assay. RESULTS: The administration of rIL-12 or rIFN gamma to mice immunized with CII in IFA restored the Th1 response and resulted in the development of arthritis. We then determined whether immunization with CII in IFA had the capacity to prevent and/or ameliorate collagen-induced arthritis. A single intraperitoneal injection of CII in IFA prevented arthritis when given at the time of immunization with CII in CFA and reduced disease severity when given at the time of arthritis onset. The administration of CII in IFA resulted in a profound down-regulation of IFN gamma production and an up-regulation of IL-10 in cultures of draining lymph node cells. CONCLUSION: These findings demonstrate that it is possible to deflect an ongoing pathogenic Th1 response to an antigen by reimmunization of the same antigen with a Th2-polarizing adjuvant.

Animals↗

High-performance liquid chromatographic-fluorescent method to determine chloroacetaldehyde, a neurotoxic metabolite of the anticancer drug ifosfamide, in plasma and in liver microsomal incubations.

Chloroacetaldehyde (CA) is a nephrotoxic and neurotoxic metabolite of the anticancer drug ifosfamide (IFA) and is a dose-limiting factor in IFA-based chemotherapy. Plasma levels of CA in IFA-treated cancer patients are often difficult to determine due to the lack of a sufficiently sensitive and specific analytical method. We have developed a simple and sensitive HPLC method with fluorescence detection to measure CA formation catalyzed by liver cytochrome P450 enzymes, either in vivo in IFA-injected rats or in vitro in liver microsomal incubations. This method is based on the formation of the highly fluorescent adduct 1-N(6)-ethenoadenosine from the reaction of CA with adenosine (10 mM) at pH 4.5 upon heating at 80 degrees C for 2 h. The derivatization mixture is directly injected onto a C18 HPLC column and is monitored with a fluorescence detector. Calibration curves are linear (r > 0.999) over a wide range of CA concentrations (5-400 pmol). The limit of detection of CA in plasma using this method is <0.1 microM and only 50 microl of plasma is required for the assay. By coupling this method with a recently described HPLC-fluorescent method to determine acrolein, a cytochrome P450 metabolite of IFA formed during the activation of the drug by 4-hydroxylation, the two major, alternative P450-catalyzed pathways of IFA metabolism can be monitored from the same plasma samples or liver microsomal incubations and the partitioning of drug between these two pathways thereby quantitated. This assay may prove to be useful for studies of IFA metabolism aimed at identifying factors that contribute to individual differences in CA formation and in developing approaches to minimize CA formation while maximizing IFA cytotoxicity.

Acetaldehyde↗

Evaluation of a safe and sensitive Spike protein-based immunofluorescence assay for the detection of antibody responses to SARS-CoV.

Previously, we have identified a truncated antigenic fragment named protein C [441 to 700 amino acids (a.a.)] as the immunodominant fragment of Spike (S) protein of severe acute respiratory syndrome (SARS) coronavirus (SARS-CoV). We have now successfully expressed protein C using the baculovirus system in S. frugiperda (Sf-9) cells. This recombinant baculovirus expressing protein C was first characterized using five SARS convalescent human sera and five normal human sera. The results showed that protein C is an authentic antigen against SARS-CoV antibody. Our Spike protein-based immunoflourescence assay (IFA) based on this recombinant baculovirus-Sf-9 system was further assessed with a panel of 163 clinical samples collected during the SARS epidemic in Singapore, which include samples from 21 clinically confirmed SARS, 42 non-SARS patient sera, and 100 normal sera. The results were compared to a commercial SARS IFA kit (EUROIMMUN, Germany) and a conventional IFA test performed in Singapore General Hospital. All of the 21 SARS-positive serum samples could be recognized by our IFA, giving a specificity and sensitivity of 100%, which was compatible with both whole virus-based IFA assays. No cross-reactivity with serum samples against infectious bronchitis virus (IBV) and transmissible gastroenteritis virus (TGEV) were detected in our assays. Thus, our Spike protein-based IFA could offer a safer procedure which can be performed in a BSL-2 laboratory as it could mimic the whole virus based-IFA without any loss of sensitivity and specificity. It is also more user-friendly and cost-effective than the whole virus-based IFA.

Animals↗

Role of human liver microsomal CYP3A4 and CYP2B6 in catalyzing N-dechloroethylation of cyclophosphamide and ifosfamide.

The anticancer alkylating agents cyclophosphamide (CPA) and ifosfamide (IFA) are prodrugs that undergo extensive P450-catalyzed metabolism to yield both active (4-hydroxylated) and therapeutically inactive but neurotoxic (N-dechloroethylated) metabolites. Whereas the human liver microsomal P450 catalysts of CPA and IFA 4-hydroxylation are well characterized, the P450 enzyme catalysts of the alternative N-dechloroethylation pathway are poorly defined. Analysis of a panel of fifteen human P450 cDNAs in the baculovirus expression system ('Supersomes') demonstrated that CYP3A4 exhibited the highest N-dechloroethylation activity toward both CPA and IFA, whereas CYP2B6 displayed high N-dechloroethylation activity toward IFA, but not CPA. The contributions of each human P450 to overall liver microsomal N-dechloroethylation were calculated using a recently described relative substrate-activity factor method, and were found to be in excellent agreement with the results of inhibition studies using the CYP3A inhibitor troleandomycin and an inhibitory monoclonal antibody to CYP2B6. With CPA as substrate, CYP3A4 was shown to catalyze >/=95% of liver microsomal N-dechloroethylation, whereas with IFA as substrate, CYP3A4 catalyzed an average of approximately 70% of liver microsomal N-dechloroethylation (range = 40-90%), with the balance of this activity catalyzed by CYP2B6 (range = 10-70%, dependent on the CYP2B6 content of the liver). Because CYP2B6 can make a significant contribution to human liver microsomal IFA N-dechloroethylation, but only a minor contribution to IFA 4-hydroxylation, the selective inhibition of hepatic CYP2B6 activity in individuals with a high hepatic CYP2B6 content may provide a useful approach to minimize the formation of therapeutically inactive but toxic N-dechloroethylated IFA metabolites.

Anti-Bacterial Agents↗

Identification of Babesia microti-specific immunodominant epitopes and development of a peptide EIA for detection of antibodies in serum.

BACKGROUND: Babesia microti is a tick-borne agent that is increasingly implicated in transfusion-acquired infection, especially in immunocompromised and elderly recipients. To develop a test that can detect antibody responses to B. microti, peptide epitopes identified in two serocomplementary B. microti-specific antigens were used in a prototype EIA. STUDY DESIGN AND METHODS: A prototype peptide EIA was used to detect B. microti-specific antibodies in 15 sera taken before infection and 107 taken after infection from 59 individuals with known tick-borne infections previously confirmed by other methods. Three additional groups of samples were also tested: a proficiency panel of 18 sera positive for B. microti by IFA, 38 sera from blood donors confirmed positive by IFA, and 30 sera from random blood donors. RESULTS: The combination peptide detected 98 out of 107 sera taken after infection that were IgG blot positive (4 equivocal). This included all 12 samples that were PCR positive and six sera from smear-negative patients that were confirmed positive by PCR, immunoblot, or IFA. Of the IgG blot-positive specimens that were equivocal (four specimens) or did not react (nine specimens) by EIA, most had low IFA titers consistent with previous exposure. In a second evaluation, 15 out of 15 Babesia IFA-positive sera and 3 out of 3 Babesia-Ehrlichia IFA-positive sera were positive, whereas sera from 30 random donors were negative. Finally, of 38 IFA-positive blood-donor samples, 35 were positive by peptide EIA. The three EIA-negative sera were Western blot negative. CONCLUSION: Reactivity of the B. microti-specific peptide EIA shows a high correlation with IFA, PCR, and B. microti immunoblot in confirmed B. microti cases. The peptide EIA may be the most suitable B. microti infection test for adaptation to the blood bank environment if testing for B. microti is required in the future.

Amino Acid Sequence↗

Safety and efficacy of an imported fire ant rush immunotherapy protocol with and without prophylactic treatment.

BACKGROUND: Hypersensitivity to the sting of the imported fire ant (IFA) is a growing and significant cause of morbidity and mortality in the United States. Conventional immunotherapy with IFA whole body extract (WBE) has been shown to be effective; however, rush immunotherapy (RIT) with IFA WBE has not been studied. OBJECTIVE: In this study, we evaluated the safety and efficacy of RIT with IFA WBE and sought to determine whether prophylactic pretreatment with antihistamines and steroids reduces the systemic reaction rate associated with RIT. METHODS: Patients with IFA hypersensitivity were randomized to placebo or twice-daily terfenadine 60 mg, ranitidine 150 mg, and prednisone 30 mg initiated 2 days before RIT in a double-blinded study. The 2-day RIT protocol consisted of hourly injections to achieve a final dose of 0.3 mL 1:100 wt/vol. Patients returned on day 8 to receive 2 hourly injections of 0.25 mL 1:100 wt/vol (total, 0.5 mL) and again on day 15 for a single injection of 0.5 mL 1:100 wt/vol. Efficacy of the protocol was determined on day 22, a pair of IFA sting challenges being performed 2 hours apart. RESULTS: Fifty-nine patients were enrolled into the study; a total of 58 patients (age range, 18 to 49 years) initiated the 2-day RIT. Only 3 patients (5.2%) experienced a mild systemic reaction during the protocol. Among those experiencing a systemic reaction with RIT, there was no statistical difference between the 2 premedication groups (3.6% active and 6.7% placebo; P =.87). Sting challenges were performed on 56 patients for a total of 112+ stings; only 1 mild systemic reaction occurred (efficacy, 98.2%). CONCLUSION: RIT with IFA WBE for IFA hypersensitivity is both safe and efficacious; the rate of mild systemic reactions is low. Premedication is not necessary, inasmuch as prophylactic pretreatment with antihistamines and steroids did not reduce the systemic reaction rate associated with RIT.

Adolescent↗