Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Forensic Ballistics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

X-ray mapping technique: a preliminary study in discriminating gunshot residue particles from aggregates of environmental occupational origin.

The possibility of detection of lead-antimony-barium aggregates from non-firearm sources is confirmed according to the tests performed on brake pads, and firework and automobile workers. Moreover, information on particles taken from cartridge cases shows the relative feeble importance of the morphology in distinguishing gunshot residues (GSRs). Furthermore, also the presence in the spectrum of other elements (e.g., iron) is not so conclusive. In this panorama, the possibility of discriminating gunshot residue particles from other non-firearm lead-antimony-barium aggregates is investigated: the proposed method is based on X-ray mapping technique--currently applied used in Reparto Carabinieri Investigazioni Scientifiche in Rome, the forensic service of Italian Carabinieri--according to which the spatial distribution of the emission energy of each element of the sample is pictured. Gunshot residues present the same lead-antimony-barium distribution (or at least the same antimony-barium distribution with lead nodules), as some other environmental occupational aggregates do not (different plaques of lead, antimony, and barium). So, X-ray mapping technique can offer a new fundamental evaluation parameter in analysis of gunshot residues with scanning electron microscopy/energy-dispersive (SEM/EDS) spectrometry, and new standards could be considered.

Forensic Ballistics↗

Indian homemade firearm--a technical review.

A wide variety of homemade (country made) firearms are involved in crime cases in India. These firearms are made up of very cheap material and are not safe for firing. Moreover, the country made firearms are different in their design, loading and locking mechanism, cocking and firing arrangements. In this paper we have studied the characteristic features of 300 country made firearms received for examination in the Central Forensic Science Laboratory (CFSL), Chandigarh during last two decades. The characteristic features of these firearms are so unique that the fired crime bullets or cartridges can easily be matched with the test. It is hoped that such information will be useful for firearm experts in case of interpretation.

Equipment Design↗

Comparison of injuries caused by the pistols Tokarev, Makarov and Glock 19 at firing distances of 10, 15 and 25cm.

Firings at cloth targets and at human skin from autopsy material were performed from the pistols 7.62 mm Tokarev (TT), 9 mm Makarov (PM) and 9 x 19 mm Glock 19 with common ammunition. The differences were in the soot deposit pattern, the degree of scorching of the synthetic fibres on the edges of the entrance hole and in the findings of the soot and the gunpowder particles. The results were similar on the cloth and on the skin targets. In the case of the TT and the PM, the soot deposit patterns reminded of a blossom or shafts of rays or fans, or the bullet wipe had four narrow and four wide sections regarding the number of lands and grooves. The TT left a large amount of soot and many gunpowder particles and caused the melting of the synthetic fibres on the edges of the entrance hole, producing a defect of the material 0.1-0.3 cm in diameter and defects of textile fibres around the entrance hole. In the skin the TT caused many intraepithelial tears, folds of the epidermis and recesses of the epidermis containing soot. Firings from the PM and the Glock 19 caused the melting only of the ends of individual synthetic fibres on the edges of the entrance hole. The PM left a large amount of soot and only a few gunpowder particles. The Glock 19 gave the least soot and the greatest number of gunpowder particles and also caused tears and recesses in the epidermis. Only in the case of the Glock 19, hexagonal or polygonal zones were seen in the soot deposit pattern. The differences in the soot pattern were more distinct at the firing distance of 10 cm. By increasing the distance from 10 to 15 cm, the intensity of soot diminished and began to disappear at 25cm, but remained more visible in the case of the TT. The gunpowder particles could be found in the epidermis and deeper in both layers of the dermis at all distances fired from the TT and the Glock 19. In the case of firings from the PM, at the distance 10 cm some of the gunpowder particles had penetrated into the dermis and most of them were in the upper layer of the dermis. At the firing distance of 15 and 25 cm, the gunpowder particles were only on and in the stratum corneum.

Firearms↗

Contact shot with unusual soot pattern.

In a suicidal shot to the temple two roundish zones of powder soot blackening were found above the entrance wound. The paired zones of powder soot blackening were caused by two gas outlets located on the upper side of the muzzle end of the weapon used (converted blank cartridge pistol of make Rhöner). The conclusions that can be drawn from this particular soot pattern with regard to the type of the weapon, the muzzle-to-target distance, the direction of fire and the way of holding the weapon are discussed.

Forensic Ballistics↗

Shotgun shooting in northern India--a review (1980-1999).

Central Forensic Science Laboratory (CFSL), Chandigarh undertakes the examination of the crime cases of some northern states of India. The shooting cases of last two decades (1980-1999) involving shotguns were analysed in this laboratory. This paper consists of the study of 360 actual cases of shotguns for evaluation of various parameters, such as type of firearm, number of firearm and firing, location of wound, age, occupation, sex and caste of accused and victim, etc. Out of 360 cases, 253 (70%) were classified as homicidal, 68 (19%) accidental, 11 (3%) suicidal, 9 (2.5%) hunting and 19 (5.5%) cases of insufficient information including the cases of illegal possession of firearm. Single Barrel Breech Loading (SBBL) gun 144 (40%) was preferred over Single Barrel Muzzle Loading (SBML) 109 (30.3%), Double Barrel Breech Loading (DBBL) 72 (20%) and Double Barrel Muzzle Loading (DBML) gun 35 (9.7%). All the breechloader guns were of 12 bore. Muzzleloader gun were recovered only from the remote rural areas. Three hundred and thirty-one (92%) cases involved single, 22 (6%) double and 7 (2%) more than two shotgun. Majority of cases were found of single firing 288 (80%), followed by double 29 (8%) and multi-firing 18 (5%). Eleven (3%) cases were of misfiring and in 14 (4%) cases information was not available. Accidental and suicidal cases had only one firing. The mean age for male and female victim was 31 and 24 years, respectively. Occupationally, agriculture is predominating over business, service and security guards for accused and for victim agriculture followed by service, business, student and security guards are in the descending order. Caste wise the most aggressive community of Kshatriyas is predominating as accused and victim over lower cast people. Head (64%) being a vital part was chosen most frequently for committing suicide followed by body (36%). Service personnel committed maximum number of suicide.

Accidents↗

Importance of radiological diagnosis applied to necroscopy.

The authors evaluate the consequences of incomplete necroscopic examinations wherein it was impossible to apply radiological resources to locate firearm projectiles. The study includes 8185 reports from the Instituto Médico-Legal Afrânio Peixoto in Rio de Janeiro, Brazil, representing the totality of corpses processed from January to December 2001; of these, 3122 were gunshot victims, 309 of which were buried with unremoved projectiles, being liable to future judicial reappraisal. During the same period, there were 23 exhumation requests by police authorities, 12 of them querying the existence of projectiles. The authors looked into the formal reasons assumed by the medico legal experts to conclude their reports from incomplete examinations, and suggest that gunshot necroscopic examinations should follow specific protocols, as incomplete autopsies will require further exhumations, at unnecessary additional costs.

Autopsy↗

Injury pattern of the Flash-Ball, a less-lethal weapon used for law enforcement: report of two cases and review of the literature.

Less-lethal weapons are used in law enforcement to neutralize combative individuals and to disperse riot crowds. Local police recently used such an impact weapon, the Flash-Ball, in two different situations. This gun fires large rubber bullets with kinetic energies around 200 J. Although it is designed to avoid skin penetration, impacts at such energies may still create major trauma with associated severe injuries to internal organs. This is a report of 2 patients shot with the Flash-Ball who required medical attention. One could be discharged quickly, but the other required hospitalization for heart and lung contusion. Both patients required advanced investigations including computed tomography (CT) scan. The medical literature on injuries induced by less-lethal impact weapons is reviewed. Impacts from the Flash-Ball can cause significant injury to internal organs, even without penetration. Investigations as for other high-energy blunt traumas are called for in these cases.

Adult↗

Forensic value of gunpowder tattooing in identification of multiple entrance wounds from one bullet.

Multiple entrance gunshot wounds can give useful information in forensic evaluation of deaths from homicide and suicide. Although the presence of multiple entrance gunshot wounds does not absolutely exclude the possibility of suicide, they are important to the forensic investigators and pathologists in cases of assault, attempted homicide and suicide as they provide important clues for determination of number of shots fired and direction of firing. We present a case of 16 years of young woman who was shot to death by her husband. External examination revealed an entrance wound with semi-lunar shot residue at the dorsal side of her left hand at 5th metacarpus, and exit wound on the hypothenar muscle. There was also a second wound entrance located on her left zygoma. Direction of the bullet was downward traveling from left-to-right. Initially it was thought that there were two close shots, but when her left hand was placed over the malar area her face, it was determined that the gunshot powder tattoos were completing the nature of a single shot from a close distance. Crime scene investigation revealed only one cartridge casing. The autopsy and radiography findings showed that the bullet was entered from dorsal site of the left hand exiting from the palm and re-entering from the zygomatic region, hit the base of the skull, and remained in the soft tissue of the right mandible after passing the soft palate. The bullet was caused an incomplete laceration of the right internal arteria carotid and she died of internal and external bleeding. Detailed investigation of gunshot residues can provide important information for clarification of close distance gunshot wounding. We present this case due to its interesting nature, and to highlight the importance of detailed investigation of the gun powder residues in cases with multiple entry wounds.

Adolescent↗

Pseudo-gunpowder stippling caused by fragmentation of a plated bullet.

In this report we present a case of pseudo-gunpowder stippling caused by fragmentation of a plated bullet. Investigation of the incident revealed absence of an interposed target, no evidence of ricochet, and a normally functioning, undamaged weapon. Electroplated ("plated" or "coated") bullets are relatively uncommon. They look similar to jacketed bullets in that the lead core is covered by a copper-colored jacketlike material. However, the copper-colored plating material is thinner than the typical jacket material. In certain instances, the plating may strip away from the lead core during transit through the barrel of the weapon and can produce injuries that mimic gunpowder stippling. Forensic pathologists are advised to be aware of this phenomenon. Misinterpretation of such wounds could result in improper classification of range of fire or improper conclusions about the presence or absence of an interposed target or ricochet.

Adolescent↗

An unusual missile-type head injury caused by a stone: case report and medicolegal perspectives.

Missile head injury is predominantly caused by firearms; however, small blunt objects such as a stone can be propelled into the air and cause a low-velocity-type missile injury, as described in this case report. Since the cerebral damage in low-velocity missile injuries is usually focal, there might not be disturbance of consciousness until secondary brain damage occurs; therefore, adequate medical supervision is necessary to prevent and treat potentially fatal complications in a timely manner. This is a rare case of a penetrating missile wound of the head, most likely caused by the use of a stone propelled by a slingshot that penetrated the skull and lacerated the brain with the stone embedded within the substance of the brain. The deceased died at home 2 days later from focal suppurative meningitis with cerebral abscess formation and a subdural hemorrhage.

Adult↗

Velocity necessary for a BB to penetrate the eye: an experimental study using pig eyes.

PURPOSE: To determine the V-50 threshold velocity needed for a steel BB to penetrate the eye of a 230-pound pig. METHOD: BBs were shot at a distance of 10 feet into the corneas of pig eyes with a pump-action BB gun. RESULTS: The V-50 velocity for corneal penetration and serious disruption of the eye was found to be 246 ft/sec. CONCLUSION: Due to the nearly identical size and anatomy of the human eye to the pig eyes used in this study, it is felt that 246 ft/sec is a reasonable approximation of the velocity needed to penetrate the human eye.

Animals↗

Physical forms of contemporary small-arms propellants and their forensic value.

Intermediate gunshot wounds typically produce powder tattooing and/or stippling of the skin. The size and density of such powder-induced injuries around an entry wound are used to estimate the separation distance between the muzzle of the responsible firearm and the entry site through test firings at selected muzzle-to-target distances, with ammunition comparable to the injury-producing round and the evidence firearm. The foregoing is well known to forensic pathologists who document and describe such powder patterns in gunshot victims and firearm examiners who customarily produce the test-fired powder patterns for subsequent range-of-fire determinations. Less known, particularly to pathologists, is the considerable variety in forms of modern nitrocellulose propellants, their effects on powder-induced injuries to human skin, and the value of these varied physical forms in the reconstruction of shooting incidents. These factors are the subject of this article.

Carbon↗

The deadly broomstick: an unusual missile injury to the neck.

A 51-year-old man was struck by the tip of a broomstick weighing 1000 g at the left side of the neck, upon which he collapsed. Intense but delayed cardiopulmonary resuscitation restored the circulation roughly 30 minutes after the incident. Upon admittance to a nearby hospital, an extensive hypoxic cerebral damage was diagnosed. Death due to the severe cerebral damage occurred 5 hours after the incident. An autopsy demonstrated a severe subcutaneous traumatization of the left side of the neck, with a hemorrhage compressing the carotid bifurcation. A prolonged excitation due to this ongoing compression of the baroreceptors in the carotid sinus was assumed to have led to a cardiac arrest. In this case report, the authors discuss the underlying pathophysiology of this potentially lethal and rare reflexogenic incident also known as the Hering reflex and discuss possible therapeutic measures.

Autopsy↗

Image analysis as an adjunct to sodium rhodizonate test in the evaluation of gunshot residues: an experimental study.

It is important to investigate the clothing, as well as the body, to determine the range of fire of entry wounds in firearm injuries. Clothing can affect the amount of gunshot residues (GSR) reaching the body and their distribution. The amount and distribution of the GSR also vary according to the distance between the firearm and the target. Sodium rhodizonate test provides valuable data when clothing is available for examination. In the absence of clothing, light microscopic examinations may add additional information regarding the range of fire. In this study, a sodium rhodizonate test was done on 80 garment samples containing the bullet entrance. The 80 calfskin samples were processed histologically and were stained using Alizarin Red S. These were also evaluated with computer-assisted image analysis. Gross residues were seen on military camouflage clothing in samples from < or = 45-cm group. White flannel undershirts under the military camouflage contained rhodizonate-positive particles only around the contact wounds. With image analysis, however, the residues could be detected also in the skin samples of the 2.5-cm- and 5-cm-range groups. We suggest that the image analysis can be combined with other techniques and it can provide valuable data in the determination of entry wounds and also in the estimation of firing distance.

Clothing↗

Visualization of bullet track and bullet by radionuclide brain scintigraphy.

Radionuclide brain scintigraphy is a commonly performed examination for the confirmation of brain death. Although the absence of scintigraphically detectable flow of lipophilic tracers to the brain combined with the lack of uptake in the brain is considered consistent with brain death in the appropriate clinical scenario, the cause of death itself is usually not apparent on the scan. A case of bullet track and bullet visualization during a radionuclide brain death study with Tc-99m hexamethylpropyleneamine oxime (HMPAO) is described.

Adult↗