Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ELISA”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Detection of Cysticercus cellulosae antigens in cerebrospinal fluid by dot enzyme-linked immunosorbent assay (Dot-ELISA) and standard ELISA.

The dot enzyme-linked immunoassay and standard enzyme-linked immunoassay were used to detect Cysticercus cellulosae antigens in cerebrospinal fluid of patients suffering with neurocysticercosis. Using the dot enzyme-linked immunoassay, 10 of 17 patients (59%) were positive at a reciprocal titer of 128 (range 128-1,024). In the standard assay, 13 of 17 (77%) were positive (range 128-512). Specificity was 100% in both assays using 48 cerebrospinal fluids from patients with various central nervous system infections. The quantification of antigens in cerebrospinal fluid using standard assay and photometric readings showed a range of 17 to 138 ng/ml. The results indicate that both assays are sensitive, specific, and economical for the diagnosis of neurocysticercosis.

Adult↗

Mycobacterium avium subsp. paratuberculosis infection in cattle in Austria, diagnosis with culture, PCR and ELISA.

Serum samples from healthy, infected (n=11) and diseased (n=2) cattle as well as positive (n=17) and negative (n=41) reference sera were tested for antibodies to Mycobacterium avium subsp. paratuberculosis with two ELISA-methods (A-ELISA, Allied Monitors, Fayette, USA; H-ELISA, Institute of Microbiology and Animal Diseases, Veterinary University Hannover). Fecal samples of these animals were examined by PCR and culture. Also field serum samples found to be positive (n=664) or inconclusive (n=1589) by A-ELISA during a survey done on 11028 cattle of 2757 farms at different districts in Austria were retested with H-ELISA (Gasteiner et al., 1999). In both ELISA-methods total agreement between antibody detection and shedding of M. avium subsp. paratuberculosis (PCR, culture) in cases of diseased animals during the testing period was found. In subclinically infected animals H-ELISA showed a better correlation with the results of PCR and fecal culture. Reference serum samples of culturally negative cattle were negative in 98% by H-ELISA and in 82% by A-ELISA, and those of positive animals were positive in 59% by H-ELISA and in 82% by A-ELISA. The 664 A-ELISA positive field serum samples were positive in 20.5%, inconclusive in 32.5% and negative in 47% by H-ELISA. A-ELISA inconclusive sera gave positive reactions by H-ELISA in 5.2%, negative in 74.8% and inconclusive results in 20%. The highest prevalence of antibodies (7.9% by A- and 2.2% by H-ELISA) against M. avium subsp. paratuberculosis were found in cattle at the age of six and seven years. Seropositive animals were found at all tested ages. The A-ELISA gave two to three times more positive reactors than the H-ELISA. Also both tests showed the highest prevalence of reagents among Holstein Friesian (6.2% by A-ELISA, 2.5% by H-ELISA) followed by other cattle breeds. Seropositive cattle were observed in all districts of Austria in 3. 3-7.1% and in 0.5-1.8% of herds according to A- and H-ELISA, respectively.

Animals↗

Sensitivity and specificity of anti-HIV ELISA employing recombinant (p24, p66, gp120) and synthetic (gp41) viral antigenic peptides.

We have developed two immunoassay systems, one designated HIV (p24, p66, gp41) ELISA that uses as antigens the immunodominant epitopes mixed from each of three major groups of HIV-1 proteins: the core (p24), the pol (p66) and the env (gp41) gene. The other immunoassay system consists of four separate ELISAs for detection of single antibodies to HIV gag gene (p24), HIV pol gene (p66) and HIV env gene (gp41 and gp120). In the present study 200 specimens from patients with AIDS and 200 specimens from patients with ARC were repeatedly positive by HIV (p24, p66, gp41) ELISA. 1425 specimens from HIV drug addicts positive at W.B. were positive at HIV (p24, gp41, p66) ELISA. In addition, 60 samples that were indeterminate by W.B., were repeatedly positive at HIV (p24, p66, gp41) ELISA. The sensitivity and specificity of HIV (p24, p66, gp41) is estimated to be 100%. In this study 1507 specimens from HIV drug addicts, positive at W.B., were all positive (more than one test positive) at HIV p24 ELISA, HIV gp41 ELISA, HIV p66 ELISA and HIV gp120 ELISA used in combination. 135 samples from HIV positive drug addicts, positive at standard ELISA but indeterminate at W.B., were positive by HIV p24 ELISA, HIV gp41 ELISA, HIV p66 ELISA and HIV gp120 ELISA using the same criteria as in W.B. interpretation. The specificity (defined in terms of percentage of non-reacting persons in a low risk population) of HIV p24 ELISA, HIV gp41 ELISA, HIV p66 ELISA, HIV gp120 ELISA is 100%. In this work we demonstrated that: a) HIV (p24, p66, gp41) ELISA could be used as an adjunct or reliable alternative to standard ELISA for detection or confirmation of HIV antibodies in human sera; b) the specificity and sensitivity of antibodies to p24, p66, gp41, gp120 by ELISA used alone and/or in combination, is equal to or greater than W.B.

AIDS-Related Complex↗

Validation of an indirect enzyme-linked immunosorbent assay for the detection of antibody against Brucella abortus in cattle sera using an automated ELISA workstation.

An automated indirect enzyme-linked immunosorbent assay (I-ELISA) for the serological diagnosis of bovine brucellosis was developed and validated in-house. A total of 4,803 cattle sera from South Africa (n = 3,643), Canada (n = 652), Germany (n = 240), France (n = 73) and the USA (n = 195) was used. The South African panel of sera represented 834 sera known to be positive by the Rose Bengal test (RBT), serum agglutination test (SAT) and complement fixation test (CFT), 2709 sera that were negative by CFT, and 100 sera from animals vaccinated with a standard dose of Brucella abortus strain 19. Overseas sera were obtained from reference non-vaccinated brucella-free cattle (n = 834), naturally infected (n = 72), experimentally infected (n = 71), and vaccinated animals (n = 83). Also 100 sera collected from cattle in Canada and known to be positive by competitive ELISA (C-ELISA) were used. The intermediate ranges ("borderline" range for the interpretation of test results) were derived from two-graph receiver operating characteristics analysis. The lowest values of the misclassification cost-term analysis obtained from testing overseas panels, covered lower I-ELISA cut-off PP values (0.02-3.0) than those from local panels (1.5-5.0). The relatively low cut-off PP values selected for I-ELISA were due to the fact that the positive control used represents a very strong standard compared to other reference positive sera. The greater overlap found between negative and positive cattle sera from South Africa than that between reference overseas panels was probably due to the different criteria used in classifying these panels as negative (sera from true non-diseased/non-infected animals) or positive (sera from true diseased/infected animals). The diagnostic sensitivity of the I-ELISA (at the optimum cut-off value) was 100% and of the CFT 83.3%. The diagnostic specificity of I-ELISA was 99.8% and of the CFT 100%. Estimate of Youden's index was higher for the I-ELISA (0.998) than that for the CFT (0.833). Analysis of distribution of PP values in sera from vaccinated and naturally infected cattle shows that in vaccinated animals all readings were below 31 PP where in infected ones these values represented 43%. Therefore, it appears that I-ELISA could be of use in identifying some naturally infected animals (with values > 31 PP), but more sera from reference vaccinated and infected animals need to be tested to further substantiate this statistically. Of 834 sera positive by RBT, SAT and CFT, 825 (98.9%) were positive in the I-ELISA. Compared to C-ELISA the relative diagnostic sensitivity of the I-ELISA was 94% and of the CFT 88% when testing 100 Canadian cattle sera. Of 258 South African cattle sera, of which 183 (70.9 %) were positive by the I-ELISA and 148 (57.4 %) by the CFT, 197 (76.4%) were positive by C-ELISA when re-tested in Canada. One has to stress, however, that Canadian C-ELISA has not been optimised locally. Thus, the C-ELISA was probably not used at the best diagnostic threshold for testing South African cattle sera. This study shows that the I-ELISA performed on an automated ELISA workstation provides a rapid, simple, highly sensitive and specific diagnostic system for large-scale detection of antibodies against B. abortus. Based on the diagnostic accuracy of this assay reported here, the authors suggest that it could replace not only the currently used confirmatory CFT test, but also the two in-use screening tests, namely the RBT and SAT.

Agglutination Tests↗

Diagnosis of hepatitis C virus infection by ELISA, RIBA and RT-PCR: a comparative evaluation.

OBJECTIVES: To evaluate the efficacy of second-generation ELISA (ELISA-2), third-generation ELISA (ELISA-3) and third-generation recombinant immunoblot assay (RIBA 3.0) for detection of antibodies to hepatitis C virus (anti-HCV) in comparison with reverse transcriptase-polymerase chain reaction (RT-PCR) to detect HCV RNA for the diagnosis of hepatitis C. METHODS: Sera of 108 patients with chronic liver disease (CLD) were analyzed by ELISA-2, ELISA-3, RIBA 3.0 and RT-PCR in the first part of the study; in the second part, sera of 105 patients with non-chronic liver disease were evaluated with ELISA-3, RIBA 3.0 and RT-PCR. RESULTS: In the CLD group, anti-HCV was positive in 4.6%, 14.8% and 16.6% by ELISA-2, ELISA-3 and RIBA 3.0, respectively. Among these anti-HCV positive cases, HCV RNA was positive in 100%, 58.9% and 64%, respectively. ELISA-2 did not give false-positive results, but missed substantial number of anti-HCV positive cases (p < 0.001). In the second group, anti-HCV was positive in 76.3% by ELISA-3 and 68.6% by RIBA 3.0 (p:ns). HCV-RNA was positive in 88.7% of ELISA- and RIBA-positive cases; in 60% of ELISA-positive, RIBA-indeterminate cases; and in 46.4% of ELISA-negative, RIBA-negative cases. CONCLUSIONS: ELISA-2 is not a suitable assay for routine screening. ELISA-3 was at par with RIBA 3.0 and it can be recommended for routine screening for anti-HCV. RT-PCR for HCV is of value in detecting early viremic, anti-HCV negative cases; this may be of importance in the treatment of hepatitis C.

Adult↗

Determination of poliovirus-specific IgA in saliva by ELISA tests.

This study describes three ELISA methods for detection of immunoglobulin A (IgA) specific to three types of Sabin strains of poliovirus in saliva taken from 70 children aged 6-7 years vaccinated with a full course of oral poliovirus vaccine (OPV). Of the three ELISA methods (conventional IgA ELISA and two new methods described in this communication, the alpha-capture ELISA and Inhibition ELISA), alpha-capture ELISA demonstrated the highest sensitivity, with all saliva samples testing positive for Sabin poliovirus strains specific IgA antibodies of 1-3 types. Of 62 available alpha-capture ELISA positive saliva samples, all were also positive by the inhibition ELISA, and a significant correlation was found between the results. Fifty-two available saliva samples were screened by the three ELISA tests with positive results, and a significant correlation was found between the alpha-capture ELISA and the IgA ELISA; the correlation between the IgA ELISA and inhibition ELISA was not significant. The results of this study suggest that determination of Sabin poliovirus-specific IgA in human saliva by the ELISA techniques (especially by the novel alpha-capture ELISA) can be used reliably for evaluation of mucosal immunity in large groups of people immunized with poliovirus vaccines and for epidemiological studies.

Antibodies, Viral↗

Evaluation of newly developed ELISA using "MESACUP-2 test mitochondrial M2" kit for the diagnosis of primary biliary cirrhosis.

OBJECTIVES: An enzyme-linked immunosorbent assay (ELISA) using MESACUP-2 Test Mitochondria M2 kit (new-M2 ELISA) has recently become commercially available. The aim of this study was to evaluate the clinical utility of this newly developed ELISA for the diagnosis of primary biliary cirrhosis (PBC). DESIGN AND METHODS: We tested the immunoreactivity of sera from 82 Japanese PBC patients to the 2-oxo-acid dehydrogenase complex (2-OADC) enzymes by indirect immunofluorescence, enzyme inhibition assay using commercially available TRACE Enzymatic Mitochondrial Antibody (M2) Assay (EMA) kit, commercial ELISAs using MESACUP Mitochondria M2 kit (old-M2 ELISA) and new-M2 ELISA, and immunoblotting on bovine heart mitochondria. RESULTS: Each test gave the following positive results; antimitochondrial antibodies (AMA) by immunofluorescence in 71 (87%) out of the 82 sera, enzymatic inhibitory antibody to pyruvate dehydrogenase complex (PDC) by EMA in 61 (74%), immunoglobulin (Ig) G class anti-PDC antibody by old-M2 ELISA in 55 (67%), IgG/M/A class anti-E2 subunit of PDC (PDC-E2)/anti-E2 subunit of branched chain oxo-acid dehydrogenase complex (BCOADC-E2)/anti-E2 subunit of 2-oxoglutarate dehydrogenase complex (OGDC-E2) antibodies by new-M2 ELISA in 73 (89%), and IgG, IgM, or IgA class antibodies against at least one of the 2-OADC enzymes by immunoblotting in 82 (100%). Fifty-three of the 82 sera (65%) were all positive by these five assays. Of the 18 sera that were positive by new-M2 ELISA but negative by old-M2 ELISA, 12 were theoretically interpretable. Of the 11 sera that were negative for AMA by immunofluorescence but positive for at least one of anti-2-OADC enzymes by immunoblotting, four (36%) were positive by new-M2 ELISA, whereas only two and one sera were positive by EMA and old-M2 ELISA, respectively. CONCLUSIONS: Our results indicated that the sensitivity of the newly developed new-M2 ELISA was higher than that of EMA and old-M2 ELISA, and comparable with that of immunofluorescence. However, it is still unclear whether the new-M2 ELISA could replace the conventional immunofluorescence testing for routine assay requests because six (7%) sera showed discrepant results between these two assays.

Adult↗