Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “EAR CANAL”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

A comparison of transtympanic and ear canal recorded electrocochleography in clinical practice.

Electrocochleograms were recorded in a routine clinic on 21 patients by the transtympanic method and from a surface electrode in the ear canal. This was to determine whether a non-invasive technique would give the same clinical information as the normal transtympanic technique. Taking the transtympanic technique as the standard for comparison, the ear canal technique produced a significant number of errors in compound action potential threshold and width. The summating potential/compound action potential ratio could only be measured in just over half the ear canal recordings compared with the transtympanic recordings. From these results and a retrospective study of the notes looking at the effect of electrocochleography on diagnosis and management, it was concluded that the ear canal technique was not a substitute for transtympanic electrocochleography where the use of an invasive technique is justified.

Action Potentials↗

Surgery of the external ear canal.

Otitis externa may account for up to 20% of presenting complaints in small animal practice. Many of these cases are non-responsive to medical therapy and require surgical intervention. The modified Zepp procedure or lateral wall resection should be considered early in the course of the disease. Performing this procedure in advanced cases of otitis externa, which involve both the medial and lateral walls of the ear canal, is responsible for 34-47% of these cases showing no improvement. Vertical ear canal ablation is the procedure of choice when the entire vertical canal is involved but the horizontal canal is free of disease. If the disease involves both the vertical and horizontal canals, a total ear canal ablation, along with removal of the lateral aspect of the bony bulla should be performed. By removing this portion of the bulla, improved drainage is achieved, and the complication rate following total ear canal ablations is decreased.

Animals↗

Surgical management of acute ear canal separation in a cat.

A 5-year-old cat presented with haemorrhagic left aural discharge, 2 days following a road traffic accident. Otoscopic examination identified disruption of the external ear canal at the auricular/annular cartilage junction. This was managed by total ear canal ablation and lateral bulla osteotomy. Left sided facial nerve deficits were present following surgery. Eighteen months postoperatively there were no auricular problems, however facial nerve deficits persisted. There are no previous reports describing management of acute separation at the auricular/annular cartilage junction of the external ear in the cat or dog. This case report describes the presentation, diagnosis and surgical management of an acute ear canal separation at the auricular/annular junction of the external ear canal in a cat.

Accidents, Traffic↗

Fine-needle biopsy of external ear canal masses in the cat: cytologic results and histologic correlations in 27 cases.

BACKGROUND: The cytologic diagnosis of ear canal tumors is difficult or impossible by swab alone because cell exfoliation may be poor and neoplastic cells may be masked by associated inflammation. Fine-needle biopsy (FNB) can be used to obtain a higher yield of cells for diagnosis. OBJECTIVE: The purpose of this study was to assess the efficacy and diagnostic value of FNB and cytologic examination in providing an accurate diagnosis of masses growing in the external ear canal of cats. METHODS: Cytologic specimens from masses in the external ear canal, taken under inhaled, general anesthesia, were classified into 4 groups: 1) ceruminous gland hyperplasia or adenoma, 2) ceruminous gland adenocarcinoma, 3) inflammatory polyps, and 4) other neoplastic and non-neoplastic masses. Cytopathologic diagnoses were compared with the final histopathologic diagnoses, and indices of diagnostic test accuracy (sensitivity, specificity, likelihood ratios, diagnostic-odds ratios) were calculated. RESULTS: Twenty-seven masses (from 25 cats, including 2 cats affected bilaterally) were included in the study. The results showed good correspondence between cytologic and histologic diagnoses with an overall agreement index (kappa) of .74, a diagnostic odds ratio of 22, and 100% (27/27) agreement in the diagnosis of inflammatory polyps versus neoplasia (both benign and malignant). CONCLUSIONS: FNB cytopathology of external ear masses in the cat was sufficiently accurate for distinguishing inflammatory polyps from neoplasia. For differentiation of benign proliferation and malignant neoplasia, however, histopathologic confirmation is recommended.

Adenocarcinoma↗

[Exostosis of the external auditory meatus or ear canal nodes. A study of etiology and therapeutic results].

In this study we evaluated the relation between exposure of the ear canal to cold water and development of exostosis. Furthermore we wanted to evaluate the clinical outcome of surgical removal of the exostosis. The material consisted of a group of 15 winter bathers who had been exposed to cold water over a period varying from three to 45 years. All but one subject who had exposed the ear canal to cold water had developed exostoses of the ear canals. Follow-up examinations of nine patients after surgical removal of the exostosis revealed normal, well calibrated ear canals. Three winter bathers who continued the exposure to cold water developed a new exostosis.

Adult↗

Ear canal cross-sectional pressure distributions: mathematical analysis and computation.

Cross-sectional pressure distributions, natural acoustic modes, and associated cutoff frequencies are determined for real ear-canal geometries using an asymptotic theory in combination with a numerical method. The technique is particularly well suited to obtain the higher modes, which are trapped near both ends of the ear canal. Results detail the influence of the canal geometry and frequency on the spatial distribution of the pressure. Adult ear-canal geometries are determined near the concha from ear-mold sections using a light microscope interfaced to a video-data-acquisition system. Computed results compare favorably to the exact solutions for circular and square acoustic waveguides. The cutoff frequency of the two adult ear canals studied averaged 20% less than the cutoff frequency of a circular tube of identical cross-sectional area. Inserting a probe microphone into the canal decreases the rate of decay of circumferential nonplanar modes while increasing the rate of decay of radial modes. Relative to the pressure beyond the tube, insertion increases the plane-wave component of the pressure around the tube by a multiplicative factor approximately equal to the square root of the original area divided by the occluded area. Eccentric placement of the probe tube has a relatively small influence on the cutoff frequency. The transition of the pressure distribution at the entrance to a simple plane wave in the core region of the canal is calculated and shown graphically for the actual geometry of two adult subjects.

Computer Simulation↗

Acoustic intensity, impedance and reflection coefficient in the human ear canal.

The sound power per unit cross-sectional area was determined in human ear canals using a new method based on measuring the pressure distribution (P) along the length of variable cross-section acoustic waveguides. The technique provides the pressure/power reflection coefficients (R/R) as well as the acoustic intensity of the nonplanar incident wave (I+, the acoustic input to the ear) and the nonplanar outgoing wave (I-, the acoustic output of the ear). Results were compared to the classical acoustic impedance (Z) and associated plane-wave power reflection coefficient (R(Z)). Performance of the method was investigated theoretically using horn equation simulations and evaluated experimentally using pressure data recorded in nonuniform waveguides. The method was applied in normal-hearing young adults to determine ear-canal position- and frequency-dependence of I(+/-), R, and R(Z) using random phase broadband stimuli (1-15 kHz; approximately 75 dB SPL). Reflection coefficient (R) measurements at two different locations within individual human ear canals exhibited a position dependence averaging deltaR approximately 0.1 (over 6 mm distance)--a difference consistent with predictions of inviscid acoustics in nonuniform waveguides. Since this position dependence was relatively small, an "optimized" position-independent reflection coefficient was defined to facilitate practical application and intersubject comparisons.

Acoustic Impedance Tests↗

Chronic otitis externa and otitis media treated by total ear canal ablation and ventral bulla osteotomy in thirteen dogs.

Ventral bulla osteotomy was combined with total ear canal ablation for the treatment of chronic otitis externa and otitis media in 13 dogs (14 ears) that had been refractory to medical and surgical treatments. Resolution of disease occurred in 11 dogs (12 ears). One dog with unilateral disease underwent a second operation before achieving a good result. One dog was euthanatized for persistent unilateral disease after three surgical procedures. The recurrence of disease in these two dogs (15%) was associated with remnants of ear canal integument within the osseous horizontal canal or tympanic bulla. Facial paralysis occurred in four dogs (31%) and there were no complications in eight dogs (62%). This technique shows no advantage over lateral bulla osteotomy combined with total ear canal ablation for the treatment of chronic otitis externa and otitis media.

Animals↗

Ear canal reflectance in the presence of spontaneous otoacoustic emissions. I. Limit-cycle oscillator model.

Allen et al. [Abstract in Eighteenth Midwinter Research Meeting of the Association for Research in Otolaryngology, Des Moines, IA (1995)] have found that the ear canal reflectance passes through a minimum around the frequency of a spontaneous otoacoustic emission (SOAE). They considered this result to constitute evidence against active nonlinear cochlear function as the basis for SOAEs. In order to investigate theoretically the expected behavior of ear canal reflectance in the neighborhood of a SOAE associated with an active-nonlinear cochlea, we use a simplified model in which the ear drum end of the ear canal is effectively terminated by a nonlinear-active element. Under the influence of a sinusoidal driver at the entrance of the ear canal, this element will, to a good approximation, either (1) oscillate at both the frequency of the driver (at which the reflectance is determined) and the SOAE (at a suppressed level, corresponding to nonentrainment), or (2) be entrained and only oscillate at the driving frequency. The magnitude of the nonlinear ear canal reflectance is found to exceed unity only at sufficiently low stimulus levels, and occurs under conditions of entrainment and nonentrainment of the spontaneous emission. Otherwise, the reflectance is less than unity and, as a function of frequency, has a minimum around the SOAE frequency.

Ear Canal↗

Identification of neonatal hearing impairment: ear-canal measurements of acoustic admittance and reflectance in neonates.

OBJECTIVES: 1) To describe broad bandwidth measurements of acoustic admittance (Y) and energy reflectance (R) in the ear canals of neonates. 2) To describe a means for evaluating when a YR response is valid. 3) To describe the relations between these YR measurements and age, gender, left/right ear, and selected risk factors. DESIGN: YR responses were obtained at four test sites in well babies without risk indicators, well babies with at least one risk indicator, and graduates of neonatal intensive care units. YR responses were measured using a chirp stimulus at moderate levels over a frequency range from 250 to 8000 Hz. The system was calibrated based on measurements in a set of cylindrical tubes. The probe assembly was inserted in the ear canal of the neonate, and customized software was used for data acquisition. RESULTS: YR responses were measured in over 4000 ears, and half of the responses were used in exploratory data analyses. The particular YR variables chosen for analysis were energy reflectance, equivalent volume and acoustic conductance. Based on the view that unduly large negative equivalent volumes at low frequencies were physically impossible, it was concluded that approximately 13% of the YR responses showed evidence of improper probe seal in the ear canal. To test how these outliers influenced the overall pattern of YR responses, analyses were conducted both on the full data set (N = 2081) and the data set excluding outliers (N = 1825). The YR responses averaged over frequency varied with conceptional age (conception to date of test), gender, left/right ear, and selected risk factors; in all cases, significant effects were observed more frequently in the data set excluding outliers. After excluding outliers and controlling for conceptional age effects, the dichotomous risk factors accounting for the greatest variance in the YR responses were, in rank order, cleft lip and palate, aminoglycoside therapy, low birth weight, history of ventilation, and low APGAR scores. In separate analyses, YR responses varied in the first few days after birth. An analysis showed that the use of a YR test criterion to assess the quality of probe seal may help control the false-positive rate in evoked otoacoustic emission testing. CONCLUSIONS: This is the first report of wideband YR responses in neonates. Data were acquired in a few seconds, but the responses are highly sensitive to whether the probe is fully sealed in the ear canal. A real-time acoustic test of probe fit is proposed to better address the probe seal problem. The YR responses provide information on middle-ear status that varies over the neonatal age range and that is sensitive to the presence or absence of risk factors, ear, and gender differences. Thus, a YR test may have potential for use in neonatal screening tests for hearing loss.

Acoustics↗

Sound levels in a 2-cc cavity, a Zwislocki coupler, and occluded ear canals.

Probe-tube measurements of the differences in sound levels at three locations in ear canals were compared to the differences in levels measured at analogous positions in a Zwislocki coupler and a 2-cc cavity. The results support the recommendation of Sachs and Burkhard that probe tube measurements should not be made with the probe tube flush with the earmold tip and close to the sound inlet bore. In real ear canals the transfer functions to the eardrum presented by Bruel, Frederikson, and Rasmussen and by Studebaker agree well with each other but differ somewhat from the one used by Sachs and Burkhard. In agreement with Bruel et al., the data of this study reveal a plateau in the relationship between real ear and 2-cc cavity responses between about 1.6 and 4.0 kHz, the relative intensity level of which may depend upon residual ear canal volume.

Acoustics↗

Collapsed ear canals in the elderly nursing home population.

In a sample of 104 elderly nursing home residents, collapsed ear canals were found in 41% of the subjects. Age emerged as a significant factor in these data since collapsed ear canals were significantly more common among the nursing home residents that were age 80 or over. Based on these findings, mean hearing threshold data on this population will overestimate hearing loss by 2-8 dB when collapsing ear canals are not considered.

Aged↗

Accuracy of predicted ear canal speech levels using the VIOLA input/output-based fitting strategy.

OBJECTIVE: The Visual Input/Output Locator Algorithm (VIOLA) is a software-assisted method for prescribing amplification targets and selecting a hearing aid to match the targets. Although the procedure calls for selection and fitting of hearing aids in terms of their pure-tone input/output functions in a coupler, it is assumed that a hearing aid that matches the coupler prescription targets will produce specific amplified speech levels in the patient's ear canal. This investigation evaluated the validity of that assumption. DESIGN: Six hearing aids were evaluated. They were representative of linear and compression processing as well as single- and 2-channel designs. The "subject" was a KEMAR manikin with realistic assumed hearing loss and loudness perception characteristics. Each hearing aid was configured to match the subject's VIOLA prescription as closely as possible. Predicted ear canal speech levels were determined using the prescription rules and modified by the differences between coupler prescription targets and coupler performance of the actual hearing aids. With the subject wearing each hearing aid coupled to an unvented earmold, continuous speech was presented in the sound field and measured, after amplification, in the ear canal. The match between observed and predicted levels of amplified speech indicated the validity of the VIOLA assumptions under examination. RESULTS: The match between predicted and observed levels was good for soft speech input levels. As speech input levels increased, the differences between observed and predicted levels also increased, with the largest differences seen for loud speech inputs. When differences were seen between observed and predicted levels, they were always in the direction of lower than predicted ear canal levels. The differences between observed and predicted levels were attributed to the effects of limiting, effects of compression ratio in wide range compression, the individual subject's field-to-microphone transfer function, and the subject's individual real-ear-to-coupler level difference. CONCLUSIONS: Ear canal speech levels were reasonably close to predicted values, and the deviations from predicted levels were plausibly accounted for by consideration of hearing aid performance. Thus, the approach used by the VIOLA procedure holds considerable promise for extending clinical control over the complex and interactive parameters of nonlinear hearing aids. The results of this study indicate that selection and fitting of hearing aids using the current VIOLA procedure usually will result in the generation of lower than predicted ear canal speech levels, especially for loud speech inputs. However, the accuracy of the procedure could be improved substantially by modification of the software to account for the effects of limiting and those of the compression ratio in systems with compression thresholds lower than the level of unamplified loud speech.

Ear Canal↗

Ear-lobe crease and ear-canal hair as predictors of coronary artery disease in Indian population.

215 patients of different communities were selected randomly to predict the correlation between the ear-lobe crease, ear-canal hair and coronary artery disease. On analysis, it was found that prevalence of the ear-lobe crease increases with advancing age, and the incidence was much more higher in Sindhis in whom the overall incidence of CAD is also significantly high. Bilateral diagonal ear-lobe crease was found to be significantly (P less than 0.001) associated in patients with documented CAD, and a significant difference was also observed between men with and without CAD in the presence of ear-canal hair with age matched group. The combined presence of ear-lobe crease and ear-canal hair was more definite and more sensitive index of underlying CAD.

Adolescent↗

Comparison of preoperative electrostimulation data using an ear-canal electrode and a promontory needle electrode.

OBJECTIVE: To compare the electrical stimulation results of the ear-canal electrode with those of a promontory needle. PATIENTS AND METHODS: In thirty-three adult patients, the ear-canal electrode test was compared with the needle electrode promontory test with respect to sound perception, rhythm detection, frequency, and disturbing side effects. RESULTS: The ear-canal electrode test, in comparison with the needle electrode promontory test, resulted in vibrotactile sensation in addition to auditory sensation in some patients, less auditory fatigue, higher threshold levels, and lower discomfort levels. CONCLUSION: Reliable assessment of deafness in children requires, in addition to electrical stimulation, determination of the electrical evoked auditory brainstem response with the patient under anesthesia.

Adult↗

The reliability of insertion gain measurements using probe microphones in the ear canal.

Two methods are now available for measuring the insertion gain as a clinical procedure; the ear canal microphone- and the soft probe tube microphone-system. It was decided to investigate some of the variables affecting the reliability of the insertion gain measurements, such as the measurement location and head movement effects, as well as factors related to the presence of the ear canal microphone in the auditory canal. The last variable exhibited significant systematic differences of -2 to 4 dB in the measured insertion gain with the ear canal microphone compared to the measurement obtained with the probe tube microphone. The intrasubject standard deviations were about the same for both methods and less than 4 dB in the frequency range 0.25 to 4.0 kHz. Finally when making clinical hearing aid recommendations using the probe tube microphone technique the errors in one insertion gain measurement are within 95% probability +/- 2 to +/- 8 dB in the frequency range 0.25 to 4.0 kHz.

Adult↗

Itching in the ear canal due to hypocerumenosis. An effective method of treatment.

Itching of the ear canal, with oozing, edema and cracking of the skin due to absence or insufficiency of wax was treated in more than 200 cases by instructing the patient to massage the ear canal with a cotton tip applicator soaked with a hydrocortisone preparation and inserted a half to three-quarters of an inch beyond the meatus. Some 95 per cent of patients reported good to excellent results in three to four days after the beginning of treatment. In the remainder results were fair.

Cerumen↗

Treatment of recurrent otitis media that developed after total ear canal ablation and lateral bulla osteotomy in dogs: nine cases (1986-1994).

OBJECTIVE: To assess clinical findings and long-term outcome of dogs treated for recurrent middle ear infection that developed after total ear canal ablation and lateral bulla osteotomy. DESIGN: Retrospective case series. ANIMALS: Of 94 dogs (142 ears) treated by means of total ear canal ablation and lateral bulla osteotomy for end-stage otitis, 9 developed recurrent middle ear infection. PROCEDURE: Information regarding treatment and outcome were retrieved from the medical records. RESULTS: Antibiotic treatment was attempted in 8 dogs, but failed to cure recurrent otitis media in 7 of 8 dogs. Seven dogs were treated by means of exploratory surgery, which consisted of ventral bulla osteotomy and tympanic curettage. One dog was cured, 1 developed another infection and was euthanatized, and the 5 remaining dogs developed another middle ear infection after the first exploratory surgery. Infection resolved after retained epithelium was removed from the tympanic cavity during a second exploratory surgery of the bulla in these 5 dogs. CLINICAL IMPLICATIONS: Antibiotic treatment rarely is effective for resolving recurrent middle ear infection that develops after total ear canal ablation and lateral bulla osteotomy. Ventral bulla osteotomy and curettage can be a successful method of treatment, provided retained epithelium and debris are completely removed from the ear canal and tympanic cavity.

Animals↗