Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Diamond”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Electrochemical impedance sensing of DNA hybridization on conducting polymer film-modified diamond.

The impedimetric sensing of DNA hybridization on polyaniline/polyacrylate (PANI/PAA)-modified boron-doped diamond (BDD) electrode has been investigated. An ultrathin film of PANI-PAA copolymer was electropolymerized onto the diamond surfaces to provide carboxylic groups for tethering to DNA sensing probes. The electrochemical impedance and the intrinsic electroactivity of the polymer-diamond interface were analyzed after the hybridization reaction with target and non-target DNA. The impedance measurement shows changes in the impedance modulus as well as electron-transfer resistance at the stage of probe DNA immobilization (single-strand), as well as after hybridization with target DNA (double-strand). DNA hybridization increases the capacitance of the polymer-DNA layer and reduces the overall impedance of the DNA-polymer-diamond stack significantly. The polymer-modified BDD electrode shows no detectable nonspecific adsorption, with good selectivity between the complementary DNA targets and the one-base mismatch targets. The detection limit was measured to be 2 x 10(-8) M at 1000 Hz. Denaturing test on the hybridized probe and subsequent reuse of the probe indicates chemical robustness of the sensor. Our results suggest that electropolymerization followed by the immobilization of biomolecules is a simple and effective way of creating a functional biomolecular scaffold on the diamond surface. In addition, label-free electrochemical impedance method can provide direct and noninvasive sensing of DNA hybridization on BDD.

Boron↗

Ultradispersity of diamond at the nanoscale.

Nanometre-sized diamond has been found in meteorites, protoplanetary nebulae and interstellar dusts, as well as in residues of detonation and in diamond films. Remarkably, the size distribution of diamond nanoparticles seems to be peaked around 2-5 nm, and to be largely independent of preparation conditions. We have carried out ab initio calculations of the stability of nanodiamond as a function of surface hydrogen coverage and of size. We have found that at about 3 nm, and for a broad range of pressures and temperatures, particles with bare, reconstructed surfaces become thermodynamically more stable than those with hydrogenated surfaces, thus preventing the formation of larger grains. Our findings provide an explanation of the size distribution of extraterrestrial and of terrestrial nanodiamond found in ultradispersed and ultracrystalline diamond films. They also provide an atomistic structural model of these films, based on the topology and structure of 2-3-nm dimond clusters consisting of a diamond core surrounded by a fullerene-like carbon network.

Computer Simulation↗

Shallow donors with high n-type electrical conductivity in homoepitaxial deuterated boron-doped diamond layers.

Diamond is a unique semiconductor for the fabrication of electronic and opto-electronic devices because of its exceptional physical and chemical properties. However, a serious obstacle to the realization of diamond-based devices is the lack of n-type diamond with satisfactory electrical properties. Here we show that high-conductivity n-type diamond can be achieved by deuteration of particularly selected homo-epitaxially grown (100) boron-doped diamond layers. Deuterium diffusion through the entire boron-doped layer leads to the passivation of the boron acceptors and to the conversion from highly p-type to n-type conductivity due to the formation of shallow donors with ionization energy of 0.23 eV. Electrical conductivities as high as 2omega(-1) x cm(-1) with electron mobilities of the order of a few hundred cm2 x V(-1) x s(-1) are measured at 300 K for samples with electron concentrations of several 10(16) x cm(-3). The formation and break-up of deuterium-related complexes, due to some excess deuterium in the deuterated layer, seem to be responsible for the reversible p- to n-type conversion. To the best of our knowledge, this is the first time such an effect has been observed in an elemental semiconductor.

Boron↗

Application of a natural diamond detector for the measurement of relative dose distributions in radiotherapy.

The suitability of a natural diamond detector with a special contact system for the measurement of relative dose distributions in selected radiotherapy applications was studied. The performance of the diamond detector was analysed by comparison with measurements using an ionization chamber and a silicon diode detector. The good stability, high response and good spatial resolution of the diamond detector were demonstrated by relative measurements in high-energy photon and electron beams and around the 137Cs source of an afterloading device. The application of the diamond detectors for relative as well as absolute dose measurements of beta ray ophthalmic applicators was also highlighted. It is concluded that the diamond with the special contact system is a suitable detector for relative dose measurements in a wide variety of applications, especially when high response and high spatial resolution are required.

Brachytherapy↗

CVD diamonds as thermoluminescent detectors for medical applications.

Diamond is believed to be a promising material for medical dosimetry due to its tissue equivalence, mechanical and radiation hardness, and lack of solubility in water or in disinfecting agents. A number of diamond samples, obtained under different growth conditions at Limburg University, using the chemical vapour deposition (CVD) technique, was tested as thermoluminescence dosemeters. Their TL glow curve, TL response after doses of gamma rays, fading, and so on were studied at dose levels and for radiation modalities typical for radiotherapy. The investigated CVD diamonds displayed sensitivity comparable with that of MTS-N (Li:Mg,Ti) detectors, signal stability (reproducibility after several readouts) below 10% (1 SD) and no fading was found four days after irradiation. A dedicated CVD diamond plate was grown, cut into 20 detector chips (3 x 3 x 0.5 mm) and used for measuring the dose-depth distribution at different depths in a water phantom, for 60Co and six MV X ray radiotherapy beams. Due to the sensitivity of diamond to ambient light, it was difficult to achieve reproducibility comparable with that of standard LiF detectors.

Diamond↗

Thermoluminescence properties of CVD diamond for clinical dosimetry use.

The application of diamond to dosimetry is desirable because of its tissue equivalence, chemical inertness and small size, but this has not been commercially viable owing to the non-reproducible response of natural diamond. The chemical vapour deposition (CVD) of diamond permits controlled, reproducible and large-scale production of this material at potentially low cost. An investigation of some clinically relevant features like the depth-dose distribution as well as the absorbed dose profile, obtained using thermoluminescence (TL), is reported for several CVD diamond films. The TL characterisation presented here shows that CVD diamond films should be excellent TL-mode detectors in instances of radiotherapy and in vivo radiation dosimetry.

Diamond↗

Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.

Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamond (polycrystalline diamond films prepared by chemical vapor deposition) film were studied in order to test its performance as a beta radiation dosemeter. The TL response is composed of four main TL glow peaks; two of these are in the range of 150-200 degrees C and two additional peaks in the 250-400 degrees C temperature range. The integrated TL as a function of radiation dose is linear up to 100 Gy and increases with increasing dose exposure. The dose dependence of the integrated OSL exhibits a similar behavior. The observed OSL/TL behavior for the CVD diamond film clearly demonstrate its capability for applications in radiation dosimetry with special relevance in medical dosimetry owing to the diamond's intrinsic material properties.

Diamond↗

Cutting effectiveness of diamond points on commercial core composite resins and cements.

In dental clinics, composite resin and cement cores are routinely cut and polished during abutment tooth preparation. To identify their characteristics during cutting, weight-load cutting tests were performed on eight commercial core composites and two cements, using diamond points driven by an air-turbine handpiece. It became evident that the cutting effectiveness of the diamond points on nine workpieces exceeded that on natural tooth dentine, while that on one composite containing Si3,N4 filler was analogous to that on dentine. With continued use, the cutting effectiveness of the diamond point on all workpieces gradually declined. SEM observations revealed that diamond particles of the diamond point wore out with repeated use. It is clinically advised to select the core material with material characteristics during cutting and mechanical strength similar to those of dentin.

Animals↗

Tooth preparation: a study on the effect of different variables and a comparison between conventional and channeled diamond burs.

PURPOSE: The purpose of this study was to evaluate the different variables involved in tooth cutting to characterize intrapulpal temperature generation, cutting efficiency, and bur durability when using conventional and channeled diamond burs. MATERIALS AND METHODS: Forty premolars and 60 molars were selected for the study. Four diamond burs were paired according to grit size: 125-microm grit: Brasseler Coarse (Control 1) and TDA System (Test 1) burs; and 180-microm grit: Brasseler CRF (Control 2) and NTI Turbo Diamond (Test 2) burs. Each bur was used twice when cutting the premolar teeth, whereas it was used for 60 cuts when cutting the molar teeth. The data were analyzed to compare the correlation of bur design, grit and wear, amount of pressure, advancement rate, revolutions per minute, cutting time and rate, and proximity to the pulp chamber with intrapulpal temperature generation, cutting efficiency, and bur longevity. The mean values of test and control burs in each group were compared using an ANOVA (p < 0.05 for significant differences) for temperature generation and an ANOVA and the Tukey multiple range test (p< or = 0.05) for cutting efficiency and bur longevity. RESULTS: No significant difference was found in intrapulpal temperature generation while cutting premolar and molar teeth with conventional and channeled diamond burs. In both groups, the mean temperature recorded during and after the cutting procedure was lower than the baseline temperature. For premolar teeth, no significant difference was established for control and test burs for the load required to cut into the tooth and the cutting rate. However, both test burs showed significantly fewer revolutions per minute when compared to their control counterparts. For the molar teeth, the Brasseler CRF bur required a significantly lower cutting load when compared to the NTI bur, whereas no difference was noted between the other pair of burs. The cutting rate was significantly higher for both control burs, whereas revolutions per minute (rpm) were greater for control coarser burs only. Overall, channeled burs showed a significantly lower cutting efficiency when compared to conventionally designed burs. CONCLUSION: Within the limitations of this study, channeled burs showed no significant advantage over conventional diamond burs when evaluating temperature generation and bur durability. Moreover, the cutting efficiency of conventional burs was greater than that of channeled burs.

Analysis of Variance↗

Handpiece degradation associated with performance testing of diamond rotary cutting instruments.

Reliable standardized testing of dental rotary cutting instruments remains a problem because of the many significant parameters that require identifying and quantifying. In a previous study, handpiece wear or degradation was identified as a potentially significant confounding variable leading to the suggestion that the use of industrial handpieces might be necessary. Therefore, the objective of this investigation was to measure and compare industrial and dental air rotor degradation during a simulated diamond rotary cutting instrument test. Two dental and two industrial products were tested in a random sequence using three replicate samples of each air rotor. The simulated test consisted of 10 diamond instruments each making 90 passes through a float glass substrate. The testing apparatus comprised a computer-interfaced device that controlled the contact force between the cutting diamond and the substrate. Air rotor performance was based on the time required to cut a standardized path through the substrate. The performance change that occurred from diamond instrument to instrument during the simulated test was attributed to air rotor degradation. Multiple regression analyses showed significant differences between replicate samples of the same type and between regression intercepts for different air rotor types. Surprisingly, four air rotors exhibited improving performance during the simulated test. Changing air rotor performance must be considered to achieve reliability for the testing of diamond rotary cutting instruments.

Air↗

A correction method for diamond detector signal dependence with proton energy.

Small dosimeters as solid state detectors can be useful for the dosimetric characterization and periodic quality control of radiotherapy proton beams. The calibration of solid state detectors for proton beams is not a solved problem especially for ophthalmologic proton beams, where these detectors present a LET-dependent signal. In this work a PTW diamond detector has been selected because of its good signal reproducibility (0.3%) and stable response with accumulated dose. A method that takes into account the LET dependence of the diamond detector signal, at 62 MeV proton beam, is here proposed. In particular an empirical correction factor, kDD(Eo) (Rres), has been determined as a function of the residual range quality index, to correct the diamond detector signal for a proton beam of incident effective energy E0= 62 MeV. A dedicated software allows us to use the diamond detector as an on-line reference dosimeter, where an ionization chamber may be difficult to use, or for periodic quality control procedures. The article also reports a comparison between the signal dependence on proton energy of silicon, diamond, and radiochromic film detectors.

Biophysical Phenomena↗

Survey of cobalt exposure and respiratory health in diamond polishers.

This cross-sectional study was undertaken after the discovery of cobalt-related fibrosing alveolitis and bronchial asthma in diamond polishers occupationally exposed to cobalt. A total of 194 workers from 10 diamond polishing workshops and 59 workers from three other workshops from the diamond industry (control subjects) were studied; a questionnaire was administered and spirometry was performed. Cobalt exposure was assessed by environmental air sampling using both area and personal sampling and by measuring urinary cobalt concentration. When considered on a workshop basis, these environmental and biologic indices of exposure correlated well with each other. These measurements led to the definition of three cobalt exposure categories: a no exposure group, a low exposure group, and a high exposure group. The high exposure was, however, still below the present threshold limit value for cobalt (50 micrograms/m3). Spirometry showed that indices of ventilatory function (FVC and FEV1) were significantly (p less than 0.05) lower in the group with the highest exposure to cobalt. These differences were not due to differences in smoking habits. The results were confirmed when the data were analyzed by covariance analysis of lung function indices against smoking status, taking mean cobalt exposure in each workshop as a covariate, and when the data were analyzed by multiple regression analysis. This analysis showed that cobalt exposure correlated with decreased pulmonary function. Our results suggest that, during diamond polishing, exposure to cobalt at levels below the current threshold limit value is associated, on a group basis, with measurable effects on lung function parameters. The relationship between these cross-sectional epidemiologic findings and the occurrence of overt lung disease in diamond polishers remains to be established.

Air Pollutants, Occupational↗

Low-temperature growth of nanostructured diamond films.

Nanostructured diamond films are grown on a titanium alloy substrate using a two-step deposition process. The first step is performed at elevated temperature (820 degrees C) for 30 min using a H2/CH4/N2 gas mixture to grow a thin (approximately 600 nm) nanostructured diamond layer and to improve film adhesion. The remainder of the deposition involves growth at low temperature (< 600 degrees C) in a H2/CH4/O2 gas mixture. The continuation of the smooth nanostructured diamond film growth during low-temperature deposition is confirmed by in situ laser reflectance interferometry, atomic force microscopy, micro-Raman spectroscopy, and surface profilometry. Similar experiments performed without the initial nanostructured diamond layer resulted in poorly adhered films with a more crystalline appearance and a higher surface roughness. This low-temperature deposition of nanostructured diamond films on metals offers advantages in cases where high residual thermal stress leads to delamination at high temperatures.

Adsorption↗

Simulation and bonding of dopants in nanocrystalline diamond.

The doping of the wide-band gap semiconductor diamond has led to the invention of many electronic and optoelectronic devices. Impurities can be introduced into diamond during chemical vapor deposition or high pressure-high temperature growth, resulting in materials with unusual physical and chemical properties. For electronic applications one of the main objectives in the doping of diamond is the production of p-type and n-type semiconductors materials; however, the study of dopants in diamond nanoparticles is considered important for use in nanodevices, or as qubits for quantum computing. Such devices require that bonding of dopants in nanodiamond must be positioned substitutionally at a lattice site, and must exhibit minimal or no possibility of diffusion to the nanocrystallite surface. In light of these requirements, a number of computational studies have been undertaken to examine the stability of various dopants in various forms of nanocrystalline diamond. Presented here is a review of some such studies, undertaken using quantum mechanical based simulation methods, to provide an overview of the crystal stability of doped nanodiamond for use in diamondoid nanodevices.

Binding Sites↗

Durability of diamond burs for the fabrication of ceramic crowns using dental CAD/CAM.

The diamond burs of two dental CAD/CAM systems (GN and CD) were examined if they could be used to fabricate up to 21 ceramic full crowns without fracture. After one, 11, and 21 machining times, the surfaces of the diamond burs were observed and the number of particles captured on SEM pictures was counted. The average surface roughness of the crowns was also measured. All diamond burs could be used to fabricate 21 ceramic crowns without fracture. A significant decrease in the number of diamond particles was found on the surfaces of GN burs after 11 and 21 machining times, but not on those of CD burs. The average surface roughness of GN crowns significantly increased with increase in the number of machining times. A significant positive correlation was found between the average surface roughness and the number of diamond particles.

Computer-Aided Design↗

Cleaning of ophthalmic diamond scalpels.

BACKGROUND: To ensure optimal performance, it is imperative to properly maintain the condition of ophthalmic diamond scalpels. Refractive surgeons are often confronted with conflicting cleaning recommendations from manufacturers. The problem encountered is to maximize cleaning while minimizing trauma to the diamond to maintain its longevity. METHODS: The author describes a flexible graded approach to cleaning and maintaining diamond scalpels. The principle of this approach was the development of four successive levels of cleaning based on an increasing risk of trauma to the diamond: Level I--irrigation with distilled water, Level II--hydrogen peroxide or enzyme cleaning, Level III--ultrasonic and detergent cleaning, and Level IV--mechanical styrofoam block cleaning. The protocol was performed prospectively on 50 consecutive radial keratotomy cases, inspecting the blade microscopically after each cleaning step, and determining the level at which cleanliness of the blade was achieved. RESULTS: The effectiveness (clean/dirty) of each cleaning level was evaluated by the author and an experienced surgical assistant. The difficulty in accurately measuring the amount of debris and the force necessary to remove it, limited the judgments made to subjective observation. Only 2 of 50 blades were cleaned at Level I, while 41 of 48 at Level III, and 7 of 7 at Level IV. CONCLUSIONS: A multi-leveled systematic process for cleaning maintenance appears most effective for maximal performance and longevity of diamond scalpels used for refractive keratotomy surgery.

Antisepsis↗

13C spin-lattice relaxation in natural diamond: Zeeman relaxation in fields of 500 to 5000 G at 300 K due to fixed paramagnetic nitrogen defects.

13C Spin-lattice relaxation (SLR) times in the laboratory frame have been measured at room temperature as a function of field in the range of 500 to 5000 G on two natural type 1b and 1a diamonds after dynamic nuclear polarization. Each of the diamonds contains two types of fixed paramagnetic centers with overlapping inhomogeneous electron paramagnetic resonance (EPR) lines. EPR techniques have been employed to identify these defects and to determine their concentrations and relaxation times at X-band. Three different nuclear SLR paths, namely that due to electron SLR and two types of three spin processes, are discussed. The one three-spin process (TSP) (type 1) involves a simultaneous transition of two electron spins belonging to the same hyperfine EPR line and a 13C spin while the other process (type 2) involves two electron spins belonging to different hyperfine EPR lines and a 13C spin. It is shown that the thermal contact between the 13C nuclear Zeeman and electron dipole-dipole interaction reservoirs decreases with an increase in field intensity, thus forming a bottleneck in the 13C relaxation path due to the type 1 TSP. The contribution of TSP of type 1 dominates that due to electron SLR and the type 2 TSP in relaxing the 13C nuclei in type lb diamond from about 1200 to 5000 G, while for type 1a diamond it dominates from 500 up to about 2200 G. In type 1a diamond over the range 2200 to 5000 G it seems that the type 2 TSP, which involves electrons of neighboring P2 hyperfine lines, dominates that of electron spin-lattice and the type 1 TSP. Over the range 500 to about 1200 G, a field-dependent electron SLR mechanism associated with N3 centers appears to dominate the 13C SLR.

Journal Article↗

Postoperative corneal astigmatism in cataract extraction: diamond knife versus Beaver blade.

Postoperative corneal astigmatism was studied in two groups of patients who had cataract extraction. The technique in both groups was identical except for the knife used for the partial-thickness limbal incision. In 49 patients the incision was performed with a Beaver blade and in 35 patients, with a diamond knife. Six weeks postoperatively the astigmatism was 1.27 +/- 0.90 diopters (D) in the diamond knife group, and 2.85 +/- 1.78 D in the Beaver blade group (P less than 0.0001). Sixty-one percent of the Beaver blade cases had with-the-rule astigmatism and 8% had no astigmatism. Thirty-one percent of the diamond knife cases had with-the-rule astigmatism and 26% had no astigmatism. At six months, the astigmatism was equal in both groups and practically identical to that found six weeks postoperatively in the diamond knife group. We conclude that incision of the limbal tissue with a diamond knife is associated with lower postoperative astigmatism and a more stable refractive state than incision with a Beaver blade.

Astigmatism↗