Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Dentures”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Effect of reinforcement methods on the retention of resin-bonded fixed partial dentures using a composite denture tooth as a pontic: in vitro evaluation.

PURPOSE: The incorporation of composite denture teeth as pontics in resin-bonded fixed partial dentures has been deemed to be short-lived. This study investigated whether pre- or posttreatments could improve the bonding of denture tooth pontics. MATERIALS AND METHODS: A model fixed partial denture was fabricated that included composite denture teeth (Endura) bonded with 1 of 2 resin systems (C&B-Metabond or Aeliteflo). The bonding surface of the pontic was pretreated with one of three methods (air-particle abrasion [AA], AA plus silanization, or cavity preparation plus AA). The bonding areas between pontic and abutments were posttreated with 1 of 2 methods (reinforcement with fiber or metal post). Five bonded specimens for each treatment group were subjected to 20,000 thermocycles (40 degrees C to 60 degrees C; dwell time 60 s) before retentive forces (N) were determined. All data were analyzed with two-way ANOVA and Bonferroni's test (p = 0.05). RESULTS: All specimens that underwent the pre- and posttreatment outperformed untreated specimens. For the specimens bonded with C&B-Metabond and posttreated with a polyethylene fiber (Ribbond) or a metal post (DC Post), the mean retentive forces were 316 N and 301 N for mandibular specimens, and 354 N and 380 N for maxillary specimens, respectively. These values were significantly higher than those obtained with other pretreatment methods (p < or = 0.0003). For mandibular specimens bonded with Aeliteflo, specimens posttreated with Ribbond exhibited significantly higher retentive forces (332 N) compared to other specimens (p < or = 0.0001). CONCLUSION: Within the limitations of this study, the bond strength of a resin-bonded fixed partial denture incorporating a composite denture tooth as the pontic was improved by reinforcement with either a polyethylene fiber or a metal post.

Analysis of Variance↗

A statistical comparison of denture sanitation using a commercially available denture cleaner with and without microwaving.

Polymethyl-methacrylate dentures, worn by patients for periods ranging from 12 days to 48 years, were cultured and found to be heavily contaminated with a variety of microorganisms both externally and internally. A commercially available denture sanitizer, used as prescribed by the manufacturer, was ineffective at decontaminating the dentures. This study examined the effectiveness of this denture sanitizer when used in combination with a microwaving procedure. Statistical methods were used to compare the decontamination results of the denture sanitizer applied with and without microwaving. The statistical results indicated that the dentures were decontaminated most effectively when the denture sanitizer was used in conjunction with a two-minute microwave procedure.

Analysis of Variance↗

Problems of denture wearers regarding denture cleaning.

With the increase of elderly population, the number of patients who need removable prostheses increase rapidly. Denture wearers have different problems from non-denture wearers in terms of maintaining oral health. In this study, we attempted to find out specific difficulties of denture wearers with questionnaires regarding social life problems as well as oral hygiene problems. Our results indicated that most of the denture wearers considered the cleaning of denture was essential to maintain their oral health, though methods they employed showed a great deal of difference. Also denture wearers felt difficulties in cleaning their dentures when they went out.

Denture Cleansers↗

Effect of denture surface glazing on denture plaque formation.

This study evaluated, in vivo, the efficacy of a denture glazing material (Palaseal) in modifying plaque colonization of dentures. Ten subjects were selected and received maxillary temporary partial removable dentures, with complete acrylic palatal coverage. The right half of the fitting surface of the denture bases were glazed with Palaseal, whereas the other half was not glazed. One month after insertion, two fragments of the resin base of all dentures were removed (one from the glazed side and another from the non-glazed side). These samples were prepared and examined by scanning electron microscopy. Three months after insertion, other fragments were obtained and analyzed. Microscopic observation at 1 month revealed that, for all patients, the plaque film was thinner on the treated side in comparison to the non-treated side. However, at the 3-month evaluation, some areas of the glaze showed cracking, and both glazed and non-glazed sides were covered by a dense bacterial plaque film. In conclusion, the findings of this clinical experiment showed that glazing denture's fitting surface did not prevent bacterial colonization, but favored plaque removal while the glaze layer remained intact. After three months, glaze cracks created microretentive areas that increased plaque accumulation.

Acrylic Resins↗

Fixed partial dentures opposing complete dentures.

When fixed partial dentures are indicated in an arch opposing a complete denture, it is best to develop the occlusal surfaces of the fixed restorations at the same time that the opposing denture teeth are arranged in wax to permit greater flexibility and reduce the compromise in developing bilateral balanced occlusion. This article describes the development of bilaterally balanced occlusion between casting patterns for fixed partial dentures and a complete denture. The technique emulates the ease of arranging maxillary and mandibular denture teeth and can be used to develop fixed restorations with metal or porcelain occlusal surfaces. Porcelain occlusal surfaces are described because the use of porcelain is more technique sensitive.

Acrylic Resins↗

Visible light-cured denture base resin used in making dentures with conventional teeth.

A visible light-cured denture base can be made to serve as a custom record base and as the final denture base. After individual conventional denture teeth are set in wax, a matrix can be made to hold the teeth in relation to the denture base and cast after the wax is removed and during the time the light-cured resin is being added and partially cured. When the matrix is removed, additional light-cured resin can be added to establish the denture contours and the denture can be processed without flasking.

Acrylic Resins↗

Effect of denture adhesive on the retention and stability of maxillary dentures.

This study used quantitative methods to measure the effects of a denture adhesive on the retention and stability of the maxillary denture. Denture movements were measured on 20 patients during standardized chewing, swallowing, and speaking activities, first with no adhesive, and then at 0, 2, 4, 6, and 8 hours after application of an over-the-counter cream adhesive. The major findings were that the denture adhesive produced a statistically significant improvement in the retention and stability of the maxillary denture during the various chewing, swallowing, and speaking activities, for up to 8 hours; there were no statistically significant differences in improvement between a poorly fitting and well-fitting denture; and patients were able to produce significantly greater levels of incisal bite force with the use of the adhesive.

Adhesives↗

Achieving an even thickness in heat-polymerized permanent acrylic resin denture bases for complete dentures.

Permanent denture bases form the fitting surface of a denture and are constructed on a master cast, in heat-polymerized acrylic resin. These bases are strong and rigid and demonstrate both the fit and retention of the final prosthesis. General recommendations suggests a thickness of between 1.5 to 3 mm for these bases. The normal procedure for producing such a denture base is to manually adapt materials to the cast, in their plastic state, before processing. Such procedures are liable to distortion and variation in the thickness of the resultant denture base and may be unreliable. This article describes a method for achieving a consistent thickness in a heat-polymerized, permanent, acrylic resin denture base through the use of a vacuum-formed, thermoplastic blank as a template. The method is simple, and results in a denture base with a consistent even thickness.

Acrylic Resins↗

The split denture: a new technique for artificial saliva reservoirs in mandibular dentures.

Xerostomia is a relatively common complaint that can make the wearing of dentures very uncomfortable for affected individuals. To help overcome this problem, a number of techniques have been proposed for incorporating reservoirs, containing salivary substitutes, into dentures. These have had varying degrees of success. This paper presents a case of a patient suffering from xerostomia who was successfully treated with a new form of reservoir denture. This new split-denture technique resulted in a reservoir denture that provided good lubrication of the oral tissues, was easily cleaned by the wearer and was produced from routine denture materials. Details of its design, construction and other potential applications are also presented.

Acrylic Resins↗

Denture plaque and palatal mucosa in denture stomatitis: scanning electron microscopic and microbiologic study.

Denture plaque is an etiologic factor in denture stomatitis. In this study, denture and mucosa samples from nine patients were examined in the SEM and processed for microbiologic cultures. Denture plaque in patients with denture stomatitis showed a considerable thickness containing cocci, filaments, rods, yeasts, and desquamated epithelial cells. Some microorganisms were revealed in the connective tissue in one patient and phagocytizing polymorphonuclear leukocytes were found in the palatal mucosa of the patients with denture stomatitis.

Bacteria↗

Model system for the in vitro testing of a synthetic histidine peptide against Candida species grown directly on the denture surface of patients with denture stomatitis.

The denture surface provides a nidus for the growth of microbial species that act to initiate, aggravate, and maintain clinical disease. The present investigation describes the development of a model system for the testing of the effectiveness of agents against these microbial species inhabiting the denture surface. It was observed through in vitro growth patterns that the model permitted the testing of representative samples of the microbial flora. Poly-L-histidine was observed to inhibit both Candida albicans and C. glabrata from growing from the denture surface into nutrient broth. Scanning electron microscopy of control and treated denture disks revealed that poly-L-histidine had either eliminated most microbial flora from the denture surface or had effected a noticeable distortion of those Candida blastospores still present on the surface. From microbiologic studies, it appeared that poly-L-histidine had inflicted direct but not lethal damage to the still-attached distorted blastospores because the latter were still able to promote growth in agent-free broth. The antifungal effects of poly-L-histidine were observed to be dependent on the concentration of the polypeptide. The data obtained were consistent for all of the patients regardless of their denture stomatitis classification.

Aged↗

Effect of tinfoil substitute contamination on adhesion of resin denture tooth to its denture base.

At least one manufacturer claims that contamination of denture teeth with tinfoil substitute during processing is not detrimental. The purpose of this study was to determine whether tinfoil substitute contamination has any significant effect on the bond strength between acrylic resin denture teeth and their processed acrylic resin base. Eighty acrylic resin maxillary central incisors were processed to denture base material. The experimental group had the denture tooth ridgelap area contaminated with tinfoil substitute. The control group was not contaminated. The bond strength of the two groups was tested. The results indicate that contamination with tinfoil substitute significantly reduces the bond strength of acrylic resin denture teeth bonded to their denture base.

Acrylic Resins↗

Veterans Administration Cooperative Dental Implant Study--comparisons between fixed partial dentures supported by blade-vent implants and removable partial dentures. Part V: Comparisons of pretreatment and posttreatment dietary intakes.

PROBLEM: Good scientific evidence is lacking on the impact of improvement in masticatory function after prosthodontic restoration of missing teeth. PURPOSE: This study compares 1-week dietary intakes of 218 healthy, male patients, 111 patients restored with mandibular unilateral or bilateral distal base extension removable partial dentures and 107 patients with fixed partial dentures. MATERIAL AND METHODS: Dietary logs recorded before the initiation of treatment and 6-months after the baseline period after partial denture treatment were analyzed for 30 nutritional variables of food intakes including total calories, fats, carbohydrates, proteins, fiber, and a number of vitamins and minerals. RESULTS: Both before and after treatment, intakes of various nutrients were more than 25% above or below the RDAs for approximately half of the patients in both groups. No significant differences were observed between the mean scores of the two groups for any of the 30 variables either before or after treatment. However, beneficial treatment effects were seen in subsets of patients with low and high caloric intakes at entry. Both treatments increased the intakes of calories and 27 nutrients in the low caloric group and decreased the intakes of calories and 27 nutrients in the high caloric group. The decreases in the caloric intake and eight nutrients, including total protein, fat, carbohydrates, and cholesterol, were significantly greater (p < 0.05) in the fixed partial denture group than those in the removable partial denture group. CONCLUSIONS: These beneficial effects of partial dentures, if verified by other studies, may have profound clinical implications for the undernourished and obese patients.

Adult↗

Patient management and decision making in complete denture fabrication using a duplicate denture procedure: a clinical report.

A patient may have difficulty adapting to a new prosthesis for either physical or psychological reasons. This article describes a procedure for duplicating an existing denture and gives the practitioner an alternative to the traditional denture fabrication techniques. The duplicated denture fabrication technique minimizes the changes to the new denture, making it easier for the patient to adapt to new dentures. However, in-depth communication with the patient is necessary for successful denture therapy.

Aged↗

Effect of finishing and polishing procedures on the gap width between a denture base resin and two long-term, resilient denture liners.

STATEMENT OF PROBLEM: The junction between a long-term, resilient denture liner and the denture base is difficult to finish and polish due to differences in the hardness of the materials. Gaps tend to form during finishing and polishing procedures. PURPOSE: This study measured the junctional gap between 2 long-term, resilient denture liners and a denture base material after different finishing and polishing procedures were performed. The surface smoothness of the 2 liner materials also was evaluated. MATERIAL AND METHODS: Molloplast-B and an experimental, heat-polymerized methyl siloxane-resin-based denture liner were processed (according to the manufacturer's instructions) against Lucitone 199 acrylic resin. Control specimens (n = 20) were 2 mm thick and flat. Experimental specimens (n = 64) were fabricated with a raised center section: a 3- x 5- x 15-mm half-cylindrical ridge with a junction at the top of the cylinder between the liner material and acrylic resin. The specimens were finished with 1 of 6 types of burs and polished with different combinations of rubber-impregnated acrylic polishers, pumice, and tin oxide. The finished specimens were examined and photographed with a scanning electron microscope, and the largest gap along the liner/denture base junction on each specimen was measured. Three-way analysis of variance without replication (P<.05) and post-hoc t tests were used to analyze the data and compare groups. RESULTS; Averaged across finishing and polishing techniques, a larger gap was recorded for the experimental liner material (22 microm) than for Molloplast-B (14 microm) (P<.00005). Qualitative evaluation suggested that the experimental liner material polished better than Molloplast-B. The smoothest surfaces were obtained when specimens were finished with fine-tooth cross-cut carbide burs and polished with both pumice and tin oxide. A comparison between polished and unpolished specimens, averaged over materials and finishing techniques, revealed that polishing reduced gap size (P=.015). CONCLUSION: Within the limitations of this study, the 2 denture liners tested behaved similarly. The results suggest that the size of the gap at the liner/denture base junction may be affected by finishing and polishing techniques and vary among materials.

Acrylic Resins↗

Fabrication of a duplicate denture from an existing complete denture.

A technique is presented that describes the fabrication of a duplicate denture using the patient's existing complete denture. This procedure enables the practitioner to offer patients an alternative to being without a denture during a laboratory reline of an existing denture. A vinyl polysiloxane impression material is used to impress the polished surface of the existing denture as well as to block out undercuts on the impression surface of the denture before pouring a stone cast. Because of the stability of the impression material used, most of the laboratory procedures can be accomplished separate from the clinical appointment.

Acrylic Resins↗

Denture stomatitis-yeast occurrence and the pH of saliva and denture plaque.

The study comprised 30 denture wearers with generalized simple or granular inflammation in the palate and 30 without (controls). )easts, mostly Candida species, were cultivated from the maxillary dentures of all subjects with inflammation and of 23 controls. Hyphae were found in the maxillary denture smears from 28 subjects with inflammation and from 18 controls. Thus it seems unjustified to consider the occurrence of hyphae pathognomonic of denture stomatitis. The pH of whole saliva did not differ in the two groups (inflammation:mean pH 6.5, control:6.6). There was no clear relation between the pH of resting saliva and the amount of fungal cultures. Thirty minutes after a mouthrinse with 10 ml of a 25% sucrose solution, the mean saliva pH had dropped equally in both groups. With regard to the denture plaque, samples taken 40 min after the rinse indicated a more pronounced acid production in the plaque associated with inflammation. The pH of "resting" plaque was also lower in the inflammation than in the control group (mean maxillary pH 5.7 and 6.3 respectively, a=0.002). No association was found between the pH and the occurrence of hyphae in "resting" denture plaque. This supports the view that the pH is of no major importance for filamentation in vivo.

Adult↗

Denture stomatitis. Relapse tendency and removal of acquired discolourations in long-term denture disinfection with chlorhexidine.

Five patients with denture stomatitis were initially treated for 14 days with a combination of amphotericin B lozenges and denture soaking in 0.2% chlorhexidine. To prevent recurrence the dentures were then kept overnight in 0.2% chlorhexidine during five months. No relapse occurred, but the dentures (all-acrylic) became heavily discoloured by chlorhexidine. During this period fungi could not be grown either on palatal or on maxillar denture agar models, and clinical signs and symptoms were reduced further. At the end of treatment hypochlorite was used to remove chlorhexidine-induced denture stain. Brushing and soaking (0.16%) proved more efficient than brushing alone, and when a 0.60% solution was used, the stains were generally eliminated in two hours. Hypochlorites in the prevention and removal of chlorhexidine discolourations deserve further attention.

Aged↗