Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DNA extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

[DNA extraction methods of compost for molecular ecology analysis].

Molecular ecology provides new techniques for studying compost microbes, and the DNA extraction is the basis of molecular techniques. Because of the contamination of humic acids, it turns to be more difficult for compost microbial DNA extraction. Three different approaches, named as lysozyme lysis, ultrasonic lysis and proteinase K lysis with CTAB, were used to extract the total DNA from compost. The detection performed on a nucleic acids and protein analyzer showed that all the three approaches produced high DNA yields. The agarose gel electrophoresis showed that the DNA fragments extracted from compost had a length of about 23 kb. A eubacterial 16S rRNA gene targeted primer pair (27F and 1 495R) was used for PCR amplification, and all the samples got almost the full length 16S rDNA sequence (about 1.5 kb). After digested by restriction endonucleases (Hae Ill and Alu I), the restriction map showed relatively identical microbial diversity in the DNA, which was extracted by the three different approaches. All the compost microbial DNA extracted by the three different approaches could be used for molecular ecological study, and researchers should choose the right approach for extracting microbial DNA from compost based on the facts.

Bacteria↗

Microchip-based cell lysis and DNA extraction from sperm cells for application to forensic analysis.

The current backlog of casework is among the most significant challenges facing crime laboratories at this time. While the development of next-generation microchip-based technology for expedited forensic casework analysis offers one solution to this problem, this will require the adaptation of manual, large-volume, benchtop chemistry to small volume microfluidic devices. Analysis of evidentiary materials from rape kits where semen or sperm cells are commonly found represents a unique set of challenges for on-chip cell lysis and DNA extraction that must be addressed for successful application. The work presented here details the development of a microdevice capable of DNA extraction directly from sperm cells for application to the analysis of sexual assault evidence. A variety of chemical lysing agents are assessed for inclusion in the extraction protocol and a method for DNA purification from sperm cells is described. Suitability of the extracted DNA for short tandem repeat (STR) analysis is assessed and genetic profiles shown. Finally, on-chip cell lysis methods are evaluated, with results from fluorescence visualization of cell rupture and DNA extraction from an integrated cell lysis and purification with subsequent STR amplification presented. A method for on-chip cell lysis and DNA purification is described, with considerations toward inclusion in an integrated microdevice capable of both differential cell sorting and DNA extraction. The results of this work demonstrate the feasibility of incorporating microchip-based cell lysis and DNA extraction into forensic casework analysis.

Buffers↗

Rapid and reliable method of extracting DNA and RNA from sweetpotato, Ipomoea batatas (L). Lam.

A quick, simple and reliable method of extracting DNA from sweetpotato (Ipomoea batatas (L.) Lam.) has been developed. The method was applied successfully for extraction of total DNA from leaves and total RNA from leaves and various tissues. The yield of DNA extracted by this procedure was high (about 1 mg/g leaf tissue). The extracted DNA was completely digested by restriction endonucleases indicating the absence of common contaminating compounds. The absorbancy ratios of A260/A230 and A260/A280 of isolated RNA were approx. 2 and the yield was about 0.2 mg/g fresh wt. CIPK and tublin genes were successfully amplified by RT-PCR, suggesting the integrity of isolated RNA. The total DNA and RNA isolated by this method was of sufficient quality for subsequent molecular analysis.

2-Propanol↗

[DNA extraction using Chelex resin for oncogenic amplification analysis in head and neck tumours].

DNA extraction from tissues can be the most laborious and complex step in amplifying DNA by PCR when phenol-choroform procedure is used. We compare this lengthy, slow and expensive extraction method with other two based in the use of Chelex-100 resin. This chelating resin has been applied for extracting DNA from different tissues to use with the PCR. These procedures are simple, rapid and do not require multiple steps. In this study we compared DNA extraction from 30 head and neck squamous cell carcinomas (HNSCC) using organic solvent precipitation, Chelex 100 resin with and without proteinase K pretreatment. The results show that proteinase K-Chelex 100 procedure is as efficient as the phenol-chloroform one.

Carcinoma, Squamous Cell↗

Sensitivity of different Trypanosoma vivax specific primers for the diagnosis of livestock trypanosomosis using different DNA extraction methods.

There are several T. vivax specific primers developed for PCR diagnosis. Most of these primers were validated under different DNA extraction methods and study designs leading to heterogeneity of results. The objective of the present study was to validate PCR as a diagnostic test for T. vivax trypanosomosis by means of determining the test sensitivity of different published specific primers with different sample preparations. Four different DNA extraction methods were used to test the sensitivity of PCR with four different primer sets. DNA was extracted directly from whole blood samples, blood dried on filter papers or blood dried on FTA cards. The results showed that the sensitivity of PCR with each primer set was highly dependant of the sample preparation and DNA extraction method. The highest sensitivities for all the primers tested were determined using DNA extracted from whole blood samples, while the lowest sensitivities were obtained when DNA was extracted from filter paper preparations. To conclude, the obtained results are discussed and a protocol for diagnosis and surveillance for T. vivax trypanosomosis is recommended.

Animals↗

DNA extraction from bovine mummified fetuses and detection of factor XI gene deficiency in the mummies.

Genomic DNA extracted from bovine mummified tissue is valuable material for detection of some genes that may contribute to fetal abnormalities. In this study bovine genomic DNA was extracted from the hardened tissue samples of ten bovine mummified fetuses. The amount of genomic DNA extracted from 2 g of the mummified tissues by the phenol/chloroform-ethanol method was low (less than 4 microg/ml) for all samples. The extracted DNA was then amplified by the GenomiPhi DNA amplification system. After amplification, the amount of DNA was increased to more than 100 microg/ml for all samples. This amplification system was shown to be a good tool for amplifying the genomic DNA of the mummified fetuses. The amplified genomic DNA was used for testing the mummies for Factor XI gene deficiency, an autosomal recessive deficiency involved in the early stages of the intrinsic blood coagulation pathway. Exon 12 of the Factor XI gene of the mummies was amplified by PCR. Two of the ten mummified fetuses were heterozygous for the Factor XI gene as indicated by the presence of two amplified DNA fragments of 320 bp and 244 bp. Factor XI deficiency has already been described in Holstein cattle. However, no report is available for bovine fetus. In this study, DNA was extracted and amplified from the bovine mummified fetuses, and the samples were successfully tested for Factor XI gene deficiency in the mummies.

Animals↗

Comparative performance of portable DNA extraction protocols and bioinformatics workflows for rapid detection of gram-negative bacteria and antimicrobial resistance using Oxford Nanopore sequencing.

Oxford Nanopore Technology (ONT) enables rapid, portable pathogen identification and antimicrobial resistance (AMR) detection, but the reliability of downstream genomic analyses is highly dependent on DNA extraction quality, particularly in resource-limited settings. This study comparatively evaluated four portable bacterial DNA extraction protocols derived from three commercial kits to determine their impact on nanopore sequencing performance, bioinformatics workflow completion, and field deployability. Six gram-negative bacterial isolates (Escherichia coli, n = 4; Pseudomonas sp., n = 1; and Salmonella sp., n = 1) were processed using four extraction protocols: SwiftX DNA, SwiftX DNA with proteinase K (ProtK), SwiftX ParaBact, and NucleoSpin Microbial. Twenty-four resulting DNA extracts were sequenced on a single multiplexed MinION R10.4.1 flow cell. Sequencing data were analyzed using validated Galaxy-based generic and species-specific pipelines. Workflow completion was defined as successful progression through quality control, assembly, virulence, plasmid, and AMR detection modules. DNA purity varied substantially by extraction protocol and was strongly associated with successful workflow completion (Kruskal-Wallis, P = 0.0006). Accordingly, NucleoSpin Microbial achieved 100% workflow completion, and SwiftX ParaBact achieved 83%, while both SwiftX DNA-based protocols failed to complete full workflows. Importantly, key AMR genes required to classify isolates as multidrug-resistant were consistently detected using both NucleoSpin Microbial and SwiftX ParaBact extractions. However, NucleoSpin Microbial assemblies showed significantly higher contiguity and enabled a broader, more complete detection of virulence factors, pathogenicity islands, plasmid replicons, and accessory AMR genes, reflecting enhanced genomic resolution.IMPORTANCERapid whole-genome sequencing is increasingly used to detect antimicrobial resistance and guide public health responses, but its reliability depends strongly on how bacterial DNA is extracted. In this study, we have shown that DNA extraction method choice has a major impact on Oxford Nanopore sequencing performance across clinically relevant gram-negative bacteria. While silica column-based extraction maximized genomic completeness and analytical depth, paramagnetic bead-based reverse purification offered superior portability with sufficient resolution for frontline AMR surveillance. These findings highlight a practical trade-off between field deployability and high-resolution genomic characterization in low-resource settings.

DNA extraction↗

Comparison of methods for total community DNA extraction and purification from compost.

The differences on DNA yield and purity of three different DNA extraction protocols were compared with regard to the use for PCR and other molecular analyses. Total DNA was extracted from compost by the three protocols, and then was purified by spin-bind cartridges after being precipitated by PEG8000. The detection performed on a nucleic acid and protein analyzer showed that all three methods produced high DNA yields. The agarose gel electrophoresis showed that the fragments of crude and purified DNA had a length of about 23 kb. A eubacterial 16S rRNA gene-targeted primer pair was used for PCR amplification, and full length 16S rDNAs were amplified from all the purified DNA samples. After being digested by restriction endonucleases, the restriction map of amplified rDNA showed identical genetic diversity. The products of PCR using primer pair GC341F and 907R were also used for denaturing gradient gel electrophoresis analysis. The results indicated that high-quality DNA was extracted from compost by the three protocols, and each of the protocols is adapted to extract microbial genome DNA from compost expediently and cheaply.

DNA↗

Improvement in fetal DNA extraction from maternal plasma. Evaluation of the NucliSens Magnetic Extraction system and the QIAamp DSP Virus Kit in comparison with the QIAamp DNA Blood Mini Kit.

OBJECTIVE: Prenatal diagnostic assays have been developed using free fetal DNA circulating in the maternal blood of pregnant women. Efficient DNA extraction is crucial for a robust analysis. To improve fetal DNA yield, we tested two manual extraction methods--the NucliSens Magnetic Extraction (NMAG) system and the QIAamp DSP Virus Kit (QDSP)--against our current standard method, the widely used QIAamp DNA Blood Mini Kit (QDNA). METHODS: The fetal DNA yield of the two extraction systems was evaluated using the RHD exon 7 as target in DNA extracts of 75 plasma samples from pregnant RhD-negative women, known to have given birth to RhD-positive infanto. The total DNA yield was evaluated in 23 samples, targeting GAPDH. RESULTS: The fetal DNA yield was improved by a mean factor of 1.7 using the NMAG system, and improved by a mean factor of 1.5 using the QDSP. The total DNA yield was improved by a mean factor of 2.3 using the NMAG system, and by a mean factor of 1.3 using the QDSP. CONCLUSION: Both extraction systems tested were superior to our standard with regard to DNA yield. This improvement may have a great impact on the success of genotyping in early pregnancy.

DNA↗

Evaluation of simplified DNA extraction methods for emm typing of group A streptococci.

Simplified methods of DNA extraction for amplification and sequencing for emm typing of group A streptococci (GAS) can save valuable time and cost in resource crunch situations. To evaluate this, we compared two methods of DNA extraction directly from colonies with the standard CDC cell lysate method for emm typing of 50 GAS strains isolated from children with pharyngitis and impetigo. For this, GAS colonies were transferred into two sets of PCR tubes. One set was preheated at 94 degrees C for two minutes in the thermal cycler and cooled while the other set was frozen overnight at -20 degrees C and then thawed before adding the PCR mix. For the cell lysate method, cells were treated with mutanolysin and hyaluronidase before heating at 100 degrees C for 10 minutes and cooling immediately as recommended in the CDC method. All 50 strains could be typed by sequencing the hyper variable region of the emm gene after amplification. The quality of sequences and the emm types identified were also identical. Our study shows that the two simplified DNA extraction methods directly from colonies can conveniently be used for typing a large number of GAS strains easily in relatively short time.

Antigens, Bacterial↗

A comparison of DNA extraction and purification methods to detect Escherichia coli O157:H7 in cattle manure.

The extraction of DNA from manure and the subsequent polymerase chain reaction (PCR) amplification of virulence genes to detect pathogens require an effective method of purification. Four different methods were assessed for their effectiveness in extracting and purifying Escherichia coli O157:H7 DNA from cattle manure: phenol/chloroform purification, phenol/chloroform/Sepharose B4 spin columns, phenol/chloroform/polyvinylpolypyrrolidone (PVPP) spun columns, and Mo Bio UltraClean kit. A PCR assay targeting the shiga-like toxin I gene (sltI) was carried out to determine the effectiveness of the four methods in removing PCR inhibitors from the manure samples. All methods were used to extract a manure slurry and the cleanliness of the samples was tested by the PCR with varying concentrations of spiked E. coli O157:H7 target DNA. The PVPP spun columns and the UltraClean kit had the best detection limit, detecting 20 pg of E. coli DNA (about 2x10(3) cells) per 100 mg of manure. The UltraClean kit and the PVPP spun columns also had the best and similar detection limits of 3x10(4) CFU/100 mg manure when E. coli O157:H7 cells were spiked into the manure sample and purified by all four methods. The enrichment of cells after inoculation into manure was performed using tryptic soy broth at 37 degrees C for 5 h. Both the PVPP spun columns and the UltraClean kit methods were used to purify the enriched samples and were able to detect initial inocula of 6 CFU/100 mg manure, indicating that the two methods were highly efficient in purifying DNA from manure samples.

Animals↗

Proboscidean DNA from museum and fossil specimens: an assessment of ancient DNA extraction and amplification techniques.

Applications of reliable DNA extraction and amplification techniques to postmortem samples are critical to ancient DNA research. Commonly used methods for isolating DNA from ancient material were tested and compared using both soft tissue and bones from fossil and contemporary museum proboscideans. DNAs isolated using three principal methods served as templates in subsequent PCR amplifications, and the PCR products were directly sequenced. Authentication of the ancient origin of obtained nucleotide sequences was established by demonstrating reproducibility under a blind testing system and by phylogenetic analysis. Our results indicate that ancient samples may respond differently to extraction buffers or purification procedures, and no single method was universally successful. A CTAB buffer method, modified from plant DNA extraction protocols, was found to have the highest success rate. Nested PCR was shown to be a reliable approach to amplify ancient DNA templates that failed in primary amplification.

Animals↗

A rapid and simplified method of DNA extraction for the detection of Brugia malayi infection in mosquitoes by PCR assay.

Currently used protocols for the extraction of filarial parasite DNA from mosquito samples are tedious and involve extensive use of expensive and hazardous chemicals. Therefore, in order to arrive at a simple procedure, four different methods (A, B, C and D) were tried for the extraction of DNA from mosquitoes infected with filarial parasite, Brugia malayi. Method D was found to be as efficient as the current procedure for the extraction of DNA from a single microfilaria in pools of 25 mosquitoes and the DNA was suitable for polymerase chain reaction (PCR) amplification, yielding a band of 322 base pairs with primers specific for B. malayi. Method D involved drying and crushing the mosquitoes to a powder, which was homogenized in 100 microl TE buffer, vortexed, boiled for 10 min, centrifuged at 14000 r.p.m. for 10 min, and the supernatant used for the PCR assay. Dot-blot hybridization confirmed the specificity of the PCR amplified fragment. The DNA extracted by this method was stable for about 1 year. When comparing with the standard method, the cost of a single PCR reaction, inclusive of DNA extraction, was reduced by 50% and the hands on time was minimized fivefold. Hence, this simple TE-based method is rapid, safe and also cost-effective in assessing the B. malayi infection in pools of vector mosquitoes.

Animals↗

Quantitative measurement of fungal DNA extracted by three different methods using real-time polymerase chain reaction.

Quantification of fungal populations in the environment is important for gaining a better understanding of various microbial processes. Recently, the development of real-time quantitative PCR (RTQ-PCR) has eliminated the variability associated with conventional quantitative PCR, thereby allowing the routine and reliable quantification of PCR products. Thus, in this present study, RTQ-PCR was used to quantify the fungal target DNA extracted by three commonly used DNA extraction protocols (bead mill homogenization, grinding in the presence of liquid nitrogen, and hot detergent SDS based enzymatic lysis combined with bead beating) to determine the suitability of the quantification of target DNA. For the purpose of this study, pure culture of Aspergillus fumigatus (model organism), sterilized soil seeded with a known amount ofA. fumigatus (model soil system), and woodland and grassland soil samples (environmental samples) were chosen to extract DNA by the above three different protocols. The extracted DNA was then quantified by spectroscopy and a RTQ-PCR system. 18S rDNA specific universal fungal primers were used to quantify the target part and then amplification products were verified by agarose gel electrophoresis. Standard curves used for the quantification by RTQ-PCR revealed strong linear relationships (R2=0.9994 for the primer pair NS1 and NS2 and 0.9938 for the primer pair nu-SSU-0817 and nu-SSU-1196) with a higher amplification efficiency, e=0.983 for the primer pair NS1 and NS2 and 0.956 for the primer pair nu-SSU-0817 and nu-SSU-1196. Although for pure culture the hot detergent SDS based enzymatic lysis combined with bead beating method showed the highest target DNA copy number (1.5 x 10(9) copies/microl), for the model soil system and both environmental samples the bead beating method was found to be suitable on the basis of the high target DNA copy numbers (6.16 x 10(8) and 2.7 x 10(8) copies/microl for woodland and grassland, respectively), high DNA yield (6.4 microg/g and 1.8 microg/g of soil for woodland and grassland, respectively), and high recovery on the basis of the target DNA copy number (39.2%), suggesting an overall high extraction efficiency.

Journal Article↗

Validation of a PCR-based method for the detection of various rendered materials in feedstuffs using a forensic DNA extraction kit.

A method trial was initiated to validate the use of a commercial DNA forensic kit to extract DNA from animal feed as part of a PCR-based method. Four different PCR primer pairs (one bovine pair, one porcine pair, one ovine primer pair, and one multispecies pair) were also evaluated. Each laboratory was required to analyze a total of 120 dairy feed samples either not fortified (control, true negative) or fortified with bovine meat and bone meal, porcine meat and bone meal (PMBM), or lamb meal. Feeds were fortified with the animal meals at a concentration of 0.1% (wt/wt). Ten laboratories participated in this trial, and each laboratory was required to evaluate two different primer pairs, i.e., each PCR primer pair was evaluated by five different laboratories. The method was considered to be validated for a given animal source when three or more laboratories achieved at least 97% accuracy (29 correct of 30 samples for 96.7% accuracy, rounded up to 97%) in detecting the fortified samples for that source. Using this criterion, the method was validated for the bovine primer because three laboratories met the criterion, with an average accuracy of 98.9%. The average false-positive rate was 3.0% in these laboratories. A fourth laboratory was 80% accurate in identifying the samples fortified with bovine meat and bone meal. A fifth laboratory was not able to consistently extract the DNA from the feed samples and did not achieve the criterion for accuracy for either the bovine or multispecies PCR primers. For the porcine primers, the method was validated, with four laboratories meeting the criterion for accuracy with an average accuracy of 99.2%. The fifth laboratory had a 93.3% accuracy outcome for the porcine primer. Collectively, these five laboratories had a 1.3% false-positive rate for the porcine primer. No laboratory was able to meet the criterion for accuracy with the ovine primers, most likely because of problems with the synthesis of the primer pair; none of the positive control DNA samples could be detected with the ovine primers. The multispecies primer pair was validated in three laboratories for use with bovine meat and bone meal and lamb meal but not with PMBM. The three laboratories had an average accuracy of 98.9% for bovine meat and bone meal, 97.8% for lamb meal, and 63.3% for PMBM. When examined on an individual laboratory basis, one of these four laboratories could not identify a single feed sample containing PMBM by using the multispecies primer, whereas the other laboratory identified only one PMBM-fortified sample, suggesting that the limit of detection for PMBM with this primer pair is around 0.1% (wt/wt). The results of this study demonstrated that the DNA forensic kit can be used to extract DNA from animal feed, which can then be used for PCR analysis to detect animal-derived protein present in the feed sample.

Animal Feed↗

DNA extraction using a tetramethyl orthosilicate-grafted photopolymerized monolithic solid phase.

A novel high-capacity, high-efficiency DNA extraction method is described using a photopolymerized silica-based monolithic column in a fused-silica capillary. Development involved investigation of the composition of the sol-gel monomer, fabrication conditions, and surface modifications in order to optimize the binding capacity. Extraction capacity and efficiency with the 3-(trimethoxysilyl)propyl methacrylate (TMSPM) monolith formulations fabricated in capillaries were investigated using a simple three-step procedure consisting of sample loading, washing of the solid phase, and elution of the DNA using a low ionic strength Tris buffer at pH 8. Once the TMSPM monomer concentration was optimized to yield a monolith with maximum test stability (robustness) and minimum back pressure, the monolith surface was modified by the grafting of tetramethyl orthosilicate (TMOS) for increased DNA binding capacity. After the examination of a variety of TMOS concentrations, 85% v/v TMOS was found to be optimal for DNA extraction without any obvious changes to the monolith structure. The reduction of time allowed for TMSPM hydrolysis prior to UV polymerization from 20 to 5 min led to a lower back pressure of the monolith, enabling better TMOS derivatization and therefore higher binding capacity. Minimal buffer volume (as low as 1 muL) was required to elute DNA from the solid phase, providing a DNA concentrating effect potentially important for downstream processes. While experimentation employed monolithic columns that were 12 cm in length, reduction of the length to 2 cm still allowed for a DNA binding capacity of at least 100 ng of prepurified human genomic DNA and extraction efficiencies greater than 85%. Extraction of low sample volumes (submicroliter) of human whole blood were successfully performed, with extraction efficiencies from the 2-cm monolithic column higher than those obtained from a commercial DNA extraction kit. These results position this novel matrix as an attractive alternative for solid-phase extraction of DNA and other biologically active molecules in microscale devices.

Blood↗

Comparison of DNA extraction methods for Aspergillus fumigatus using real-time PCR.

Newer methods such as PCR are being investigated in order to improve the diagnosis of invasive aspergillosis. One of the major obstacles to using PCR to diagnose aspergillosis is a reliable, simple method for extraction of the fungal DNA. The presence of a complex, sturdy cell wall that is resistant to lysis impairs extraction of the DNA by conventional methods employed for bacteria. Numerous fungal DNA extraction protocols have been described in the literature. However, these methods are time-consuming, require a high level of skill and may not be suitable for use as a routine diagnostic technique. Here, a number of extraction methods were compared: a freeze-thaw method, a freeze-boil method, enzyme extraction and a bead-beating method using Mini-BeadBeater-8. The quality and quantity of the DNA extracted was compared using real-time PCR. It was found that the use of a bead-beating method followed by extraction with AL buffer (Qiagen) was the most successful extraction technique, giving the greatest yield of DNA, and was also the least time-consuming method assessed.

Aspergillus fumigatus↗

Low sensitivity of nested PCR using Plasmodium DNA extracted from stained thick blood smears: an epidemiological retrospective study among subjects with low parasitaemia in an endemic area of the Brazilian Amazon region.

BACKGROUND: The success of PCR technique depends on many factors, such as high quality DNA pellets obtained from blood samples, good reagents and adequate conditions of amplification. Taking these limitations into account, a retrospective epidemiological study for malaria diagnosis was conducted in a mesoendemic area in the Brazilian Amazon. METHODS: A nested PCR protocol with DNA extracted from two blood storage devices obtained from Giemsa-stained thick blood smears and filter-papers was used for malaria diagnosis. The extracted DNA was used as a template to amplify approximately 100 bp species-specific sequences of the small subunit of the ribosomal RNA (18S SSU rRNA) of Plasmodium sp. The prevalence of single and mixed infections was examined in a cross-sectional survey carried out among 369 miners living in the district of Apiacás, Mato Grosso State. The parasitemia levels detected by microscopic examination were compared to the PCR results. RESULTS: DNA samples isolated from blood on filter-paper allowed the detection and identification of Plasmodium in 165 (44.7%) of the 369 individuals evaluated, while only 62 (16.8%) had positive results using DNA obtained from thick smears, a similar rate observed by microscopic examination. The sensitivities of PCR using DNA from blood smears and filter-papers were 65% and 73.0%, respectively. Low parasite infections (below 20 parasites/ micro L blood) were not detected when thick blood smears were used as a DNA source. CONCLUSIONS: Although the blood preserved as thick blood smears provides an alternative and useful tool for malaria molecular diagnosis, its relatively poor performance at low level parasitemias impairs the correct determination of malaria prevalence in epidemiological studies. However, the results obtained in the present study confirm that the use of filter-paper to collect blood is useful for field studies.

Animals↗