Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bone Cements”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Bioactive bone cement: effect of the amount of glass-ceramic powder on bone-bonding strength.

We examined the influence of the proportion of glass-ceramic powder in a bioactive bone cement of our formula on the bone-bonding ability of cement. Changes in cement bonding with time also were examined. The bioactive bone cement consisted of MgO-CaO-SiO2-P2O5-CaF2 glass-ceramic powder (AW-GC powder) and bisphenol-alpha-glycidyl methacrylate (Bis-GMA)-based resin. AW-GC powder was added to the cement as 0%, 30%, 50%, 70%, and 80% w/w. Rectangular plates (2 x 10 x 15 mm) of each cement with polished surfaces were implanted into the proximal metaphysis of the tibiae of male rabbits, and the failure load was measured by detaching tests 10 and 25 weeks after implantation. The failure loads of each cement were 0% = 0.03, 30% = 1.52, 50% = 2.67, 70% = 3.56, and 80% = 5.59 kg at 10 weeks, and 0% = 0.05, 30% = 1.68, 50% = 2.77, 70% = 3.80, and 80% = 6.37 kg at 25 weeks. Observation of the cement-bone interface revealed that all bioactive bone cements (30%-80%) formed direct contact with bone whereas intervening fibrous tissue was observed in all specimens of the 0% group. By scanning electron microscopy, all bioactive bone cements (30%-80% groups) showed direct contact with bone at the cement-bone interface. In the 0% group, direct contact with bone at the cement-bone interface was not observed. By electron-probe microanalysis, a Ca-P-rich layer was not detected at the cement-bone interfaces of the 30%-70% bioactive bone cements, but in some samples of the 80% cement specimens a thin Ca-P-rich layer (3 microns thick) was observed at the interface at 10 and 25 weeks after implantation. These results show that all of the bioactive bone cements tested had the ability to bond to bone and to function as bioactive composites of ceramics and polymers.

Animals↗

Cement viscosity affects the bone-cement interface in total hip arthroplasty.

Quantitative information regarding the interface strength and degree of cement penetration associated with cement viscosity during total hip arthroplasty is limited. The aim of the present study was to determine the effect of the viscosity of bone cement at the time of implantation on the mechanical integrity of total hip arthroplasty. Cement that was injected at an early less viscous stage produced greater failure strength in a push-out test than its more viscous counterpart.

Analysis of Variance↗

Damage accumulation, fatigue and creep behaviour of vacuum mixed bone cement.

The behaviour of bone cement under fatigue loading is of interest to assess the long-term in vivo performance. In this study, uniaxial tensile fatigue tests were performed on CMW-1 bone cement. Acoustic emission sensors and an extensometer were attached to monitor damage accumulation and creep deformation respectively. The S-N data exhibited the scatter synonymous with bone cement fatigue, with large pores generally responsible for premature failure; at 20 MPa specimens failed between 2 x 10(3) and 2 x 10(4) load cycles, while at 7 MPa specimens failed from 3 x 10(5) load cycles but others were still intact after 3 x 10(6) load cycles. Acoustic emission data revealed a non-linear accumulation of damage with respect to time, with increasing non-linearity at higher stress levels. The damage accumulation process was not continuous, but occurred in bursts separated by periods of inactivity. Damage in the specimen was located by acoustic emissions, and allowed the failure site to be predicted. Acoustic emission data were also used to predict when failure was not imminent. When this was the case at 3 million load cycles, the tests were terminated. Creep strain was plotted against the number of load cycles and a linear relationship was found when a double logarithmic scale was employed. This is the first time a brand of cement has been characterised in such detail, i.e. fatigue life, creep and damage accumulation. Results are presented in a manner that allows direct comparison with published data for other cements. The data can also be used to characterise CMW-1 in computational simulations of the damage accumulation process. Further evidence is provided for the condition-monitoring capabilities of the acoustic emission technique in orthopaedic applications.

Biocompatible Materials↗

Influence of surfactant molecules as air-entraining agent for bone cement macroporosity.

Calcium phosphate bone cements (CPBCs) represent a potential synthetic alternative to bone-graft materials in bone surgery applications. CPBCs are biocompatible, bioresorbable, and slowly are replaced by new bone in vivo. However, CPBCs do not develop a macroporosity during setting that would allow fast bone ingrowth and good osteointegration of the implant. For this reason, recent research has approached the problem of inducing macroporosity inside the bone cement without influencing its normal setting. In this study, a new method for obtaining injectable macroporous CPBCs is proposed. It is based on the use of sodium dodecyl sulphate (SDS) as an air-entraining agent. The results have shown that the liquid-to-powder ratio and the SDS concentration, as well as the diameter and the interconnectivity of the macropores, can control the micro- and macroporosity. This new technology can be used to develop and optimize new commercial products for osteoporotic bone filling applications. Furthermore, the presented method also can be used at low temperatures before an operation to produce preformed implants to fit the particular needs of a patient.

Air↗

Analysis of the shelf life of a two-solution bone cement.

Two-solution bone cement consists of methyl methacrylate monomer and poly(methyl methacrylate) polymer dissolved together to yield a viscous solution. Two solutions are used such that the initiator, benzoyl peroxide (BPO), is placed in one solution and the activator, N,N, dimethyl-para-toluidine, is placed in the other. This approach to bone cement provides for a simplified use during surgery and eliminates some of the sources of porosity formation. However, the BPO-containing solution cement will spontaneously polymerize over time and will limit the useful shelf life of this component of the system. The activator-containing component is much more stable and is not as susceptible to spontaneous polymerization. In making two-solution cements, it is envisioned that antibiotics may be incorporated and that the polymer may be sterilized using gamma(gamma)-irradiation. Therefore, this study investigated the shelf life of the initiator-containing solution bone cement and studied the effects of initiator concentration, gamma-irradiation, gentamicin addition, and the role of storage temperature. Isothermal differential scanning calorimetry (Iso-DSC) techniques were used to monitor the polymerization of BPO-containing solutions. It was found that the shelf life was highly temperature dependent and followed an Arrhenius expression where refrigeration storage (4 degrees C) yielded approximately a 12-month storage time, while 70 degrees C storage results in setting in about 5-7 min. gamma-irradiation and gentamicin addition did not significantly affect the shelf life. Initiator concentration affected storage time with higher levels resulting in shorter shelf life.

Benzoyl Peroxide↗

Osteotransductive bone cements.

Calcium phosphate bone cements (CPBCs) are osteotransductive, i.e. after implantation in bone they are transformed into new bone tissue. Furthermore, due to the fact that they are mouldable, their osteointegration is immediate. Their chemistry has been established previously. Some CPBCs contain amorphous calcium phosphate (ACP) and set by a sol-gel transition. The others are crystalline and can give as the reaction product dicalcium phosphate dihydrate (DCPD), calcium-deficient hydroxyapatite (CDHA), carbonated apatite (CA) or hydroxyapatite (HA). Mixed-type gypsum-DCPD cements are also described. In vivo rates of osteotransduction vary as follows: gypsum-DCPD > DCPD > CDHA approximately CA > HA. The osteotransduction of CDHA-type cements may be increased by adding dicalcium phosphate anhydrous (DCP) and/or CaCO3 to the cement powder. CPBCs can be used for healing of bone defects, bone augmentation and bone reconstruction. Incorporation of drugs like antibiotics and bone morphogenetic protein is envisaged. Load-bearing applications are allowed for CHDA-type, CA-type and HA-type CPBCs as they have a higher compressive strength than human trabecular bone (10 MPa).

Biomechanical Phenomena↗

Effect of triphenyl bismuth on glass transition temperature and residual monomer content of acrylic bone cements.

Self-curing acrylic bone cements are widely used in the fixation of prosthetic implants in orthopaedic surgery. Commercial bone cements are rendered radiopaque by the addition of heavy metal salts of barium and zirconia. The addition of barium sulphate adversely affects the mechanical strength and fracture toughness of bone cement and despite the fact that it has low solubility in water; its slow release and subsequent toxicity have caused concern. In an earlier study triphenyl bismuth (TPB) was found to be a viable alternative as a radiopaque agent in acrylic bone cements, which provided enhanced homogeneity. In this study we report the effect of the inclusion of TPB on the thermal properties of PMMA-based bone cements using both conventional DSC and Modulated Temperature DSC. Furthermore, analysis of the residual monomer contents is reported analysed by NMR spectroscopy in order to ascertain the influence of TPB on the polymerisation reaction. The glass transition temperature (Tg) determined by DSC showed that the values decreased with the addition of increasing amounts of TPB through both blending and dissolution methods; however, the method of incorporating TPB did not influence Tg. The magnitude of reduction was dependent of the amount of TPB and was greatest in the case of highest concentration of TPB used. A TPB melting peak was observed in the 25 wt% TPBBC, suggesting a limit to the solubility of TPB. The residual monomer analysis showed that at 10 and 15% by weight of TPB in the cement caused no significant changes in the residual monomer content but 25 wt% of TPB exhibited a significantly higher residual monomer content.

Calorimetry, Differential Scanning↗

Improvement of mechanical properties of acrylic bone cement by fiber reinforcement.

Acrylic bone cement is significantly weaker and less stiff than compact bone. Bone cement is also weaker in tension than in compression. This limits its use in orthopaedics to areas where tensile stresses are minimum. We have attempted to improve the mechanical properties of PMMA by reinforcing it with metal wires, and graphite and aramid fibers. Normal, carbon fiber reinforced and aramid fiber reinforced bone cement specimens were tested in compression. Addition of a small percentage (1-2% by weight for carbon and up to 6% for aramid) of these fibers improved the mechanical properties significantly. Due to the improved mechanical properties of fiber reinforced bone cement, its clinical use may reduce the incidence of cement fracture and thus loosening of the prosthesis.

Biomechanical Phenomena↗

Interaction of bone and hydroxyapatite filled 4-META/MMA-TBB bone cement in in vitro and in vivo environments.

Bone response to hydroxyapatite (A) fillers in the cured 4-methacryloyloxyethyl trimellitate anhydride (4-META)/metyl methacrylate (MMA) - tri-n-butyl borane (TBB) adhesive bone cement was evaluated. Two component system consisting of powder and liquid was formulated. The liquid portion was 5% 4-META in MMA and TBB; Powder was composed of 50 wt% poly(MM/a) (PMMA) and 50 wt% dense HA particles. The results indicated that the tensile strength decreased when the HA filler size increased. Thirty-six implants in three dogs for up to 12 weeks showed HA filled PMMA-4 META cement was stable in the cement-bone interface. Histologic examinations showed that the exposed HA particles at the surface of the cured cement were generally associated with bone formation without fibrous tissue, as well as interdigitation of cement to bone. Suggesting the importance of HA fillers in inducing bone apposition that results in stable cement binding to bone, thereby complementing fast initial bone fixation of the cement.

Animals↗

Mixed-mode failure response of the cement-bone interface.

Mechanical failure of the cement-bone interface can contribute to clinical loosening of cemented total hip replacements. The conditions that cause loosening are poorly understood, in part, due to a lack of information on the mechanical behavior of the cement bone interface. The purpose of this study was to determine the mechanical behavior of the cement-bone interface due to mixed-mode (combined tension and shear) loading and to develop a failure model for the cement bone interface. Laboratory tests of machined cement-bone test specimens were performed with mixed-mode loading conditions (loading angles of 22.5 degrees, 45 degrees, and 67.5 degrees) to determine the mechanical response in the pre-yield and post-yield state. After accounting for the quantity of interdigitated bone as a covariate, the mixed-mode data were combined with previous tension (0 degrees) and shear data (90 degrees) to develop a failure model for the cement bone interface. The strength of the interface was positively correlated with the quantity of interdigitated bone (r2 = 0.70, 0.53, 0.49, for 22.5 degrees, 45 degrees, and 67.5 degrees, respectively). There was a significant increase in failure strength (P < 0.001) with increasing mixed-mode angle. When all data were incorporated into an elliptical failure criterion, the average error between the actual and predicted strength was 33%. These results can now be incorporated into constitutive models of the cement bone interface to determine the initiation and progression of interface failure in cemented total hip replacements.

Aged↗

PMMA-based composite materials with reactive ceramic fillers: IV. Radiopacifying particles embedded in PMMA beads for acrylic bone cements.

New acrylic bone cements were prepared from alumina particles previously treated by 3-(trimethoxysilyl)propylmethacrylate (gamma-MPS) and embedded in poly(methylmethacrylate-co-ethylacrylate) beads with about 7 mol% of ethyl acrylate repeating units. The encapsulation was performed through a conventional suspension polymerization process. The influence of (i) the concentration of the dispersion stabilizer and (ii) the alumina content upon the shape, size, and size distribution of the acrylic beads was studied. Cements were prepared from each batch by hand-mixing alumina-filled acrylic beads with a liquid monomer mixture containing methyl methacrylate, n-butyl methacrylate, and N,N-dimethyl-p-toluidine. Benzoyl peroxide was previously added to the solid part. The powder-to-liquid ratio was equal to 2 for each formulation. Compressive strength of cured cement decreases with alumina content, whereas compressive modulus remains roughly constant. These results are in contradiction to those obtained for cements based on a mixture of gamma-MPS-treated alumina and unfilled acrylic beads. Nevertheless, they are interpreted in terms of alumina arrangement in the cement. In the first case, alumina particles contribute to the reinforcement of the dispersed acrylic phase, with poor benefits for the whole materials. In the second case, they allow the reinforcement of the continuous acrylic phase and, therefore, the cement's one.

Acrylates↗

The influence of cyclic loading on gentamicin release from acrylic bone cements.

Antibiotic-loaded acrylic bone cement is widely used in total joint replacement to reduce infections. Walking results in cyclic loading, which has been suggested to stimulate antibiotic release. The goal of this study is to compare antibiotic release from cyclically loaded bone cement with the release from unloaded bone cement. Two models of the frontal aspect of a femoral stem were cemented with CMW 1 Radiopaque G, Palacos R-G and Palamed G. Both were immersed in water, and the gentamicin concentration in the water was monitored. One model was cyclically loaded at 5 Hz during immersion achieving physiological stresses in the bone cement mantle. After 10.8 x 10(6) cycles, initial release of gentamicin from Palamed G was increased significantly for loaded over unloaded, but not from CMW 1 Radiopaque G and Palacos R-G.

Arthroplasty, Replacement, Hip↗

A more reliable method for incudostapedial rebridging ossiculoplasty: bone cement and wire.

Polymaleinate glass ionomer cement is a commercially available bone cement (Ketac Cem Radiopaque, ESPE, Germany) that can be used to reconstruct a discontinuity between the incus and the stapes. The popularity of bone cement in otologic surgery is increasing. If the missing part of the incus is too long, the results in the long term could be unsatisfying. Under such circumstances, a new method of incudostapediopexy that uses wire and involves remodeling of the long process of the incus with bone cement is introduced. A retrospective analysis of the outcomes of incudostapedial rebridging ossiculoplasty (ISRO) procedures carried out in 21 patients between June 1999 and September 2003 was performed. A total of 17 patients were treated with bone cement only; in 4 of these patients, hearing loss reoccurred within 6 months. The procedure was repeated in 2 of these patients using both bone cement and wire with satisfactory hearing results (air-bone gaps, 7.5 and 8.8 decibels hearing level [dB HL]) after 1 year. Four patients underwent ISRO wire and bone cement initially. The long-term results of these 6 "wire-and-cement" cases, which were followed for a mean of 21 months, were satisfactory (air-bone gap, 9.8 dB HL). The postoperative air-bone gap in the 15 patients who were treated by ISRO with bone cement only excluding the 2 reoperation cases was 12.1 dB HL. ISRO with bone cement is a cost-effective and safe procedure that yields good hearing results in selected cases. If the distance between eroded incus and stapes is too long to be reconstructed with bone cement alone, the surgeon should consider using wire with bone cement.

Adolescent↗

A hybrid zinc-calcium-silicate polyalkenoate bone cement.

A novel bone cement composed of sintered zinc-calcium-silicate phosphate and hybrid polyalkenoates has been developed. Synthesis and formulation of glass fillers, monomers and polymers as well as formulation of the cement were described. The effects of sintering, polymer content, glass powder/polymer liquid (P/L) ratio and comonomer on compressive strength (CS) and curing time (CT) were investigated. The effects of P/L ratio and comonomers on shrinkage as well as exotherm were also studied. Results show that the experimental cement was 61% higher in CS, 10% lower in diametral tensile strength, 35% lower in flexural strength, 62% less in exotherm, and 68% less in shrinkage, compared to conventional polymethylmethacrylate cement. With increasing polymer content and P/L ratio in the cement formulation CS of the cement increased but CT decreased. Curing time, shrinkage and exotherm of the cement decreased with increasing P/L ratio. It appears that this novel cement may be a potential candidate for orthopedic restoration if its biological performance is good and formulation is optimized.

Biocompatible Materials↗

Femoral stem insertion generates high bone cement pressurization.

Adequate bone cement pressurization is critical in obtaining optimal femoral cement mantles during total hip arthroplasty. Pressurization can be generated during insertion of the femoral stem into the cement-filled canal. This may be clinically useful in augmenting conventional cement gun pressurization. Two factors, which were expected to influence the amount of insertion-induced pressurization, are the cement's cure state (viscosity) at the time of insertion and the femoral stem profile. This study evaluated the effect of these factors on cement pressurization during stem insertion. Femoral stems were inserted at a controlled rate into a reusable, simulated femoral canal. Intramedullary pressures were monitored at four locations along the canal's medial midline. The intrusion factor quantity, which accounts for pressure magnitude, duration of pressurization, and cement viscosity, was developed to quantify pressurization. Stem insertion into late cure stage (high viscosity) cement resulted in significantly higher intramedullary pressures (as much as 187% higher) and intrusion factors (as much as 43% higher) as compared with early stage (low viscosity) cement. The highest pressures and intrusion factors were found in the distal canal. A tapered stem profile resulted in significantly higher pressures (as much as 65%) and higher intrusion factors (as much as 63%) than a straight stem.

Arthroplasty, Replacement, Hip↗

Fiber-enriched double-setting calcium phosphate bone cement.

Calcium phosphate bone cements are useful in orthopedics and traumatology, their main advantages being their biocompatibility and bioactivity, which render bone tissue osteoconductive, providing in situ hardening and easy handling. However, their low mechanical strength, which, in the best of cases, is equal to the trabecular bone, and their very low toughness are disadvantages. Calcium phosphate cement compositions with mechanical properties more closely resembling those of human bone would broaden the range of applications, which is currently limited to sites subjected to low loads. This study investigated the influence of added polypropylene, nylon, and carbon fibers on the mechanical properties of double setting alpha-tricalcium phosphate-based cement, using calcium phosphate cement added to an in situ polymerizable acrylamide-based system recently developed by the authors. Although the addition of fibers was found to reduce the compression strength of the double-setting calcium phosphate cement because of increased porosity, it strongly increased the cement's toughness (J(IC)) and tensile strength. The composites developed in this work, therefore, have a potential application in shapes subjected to flexure.

Biocompatible Materials↗

Analysis of a vinyl pyrrolidone/poly(propylene fumarate) resorbable bone cement.

A resorbable bone cement was formulated from N-vinyl-2-pyrrolidinone (VP), the unsaturated polyester poly(propylene fumarate) (PPF), and the inorganic filler tribasic calcium phosphate (hydroxy apatite). Cure, initiated by benzoyl peroxide and accelerated by N,N-dimethyl-p-toluidine, resulted in the formation of VP crosslinks between polyester chains. During cure the cement hardened from a viscous moldable putty to a rigid structure with a shore D hardness of 50-60. The purpose of this study was to determine the fractions of PPF and VP incorporated into the crosslinked structure. Dissolution of the cured cement in water followed by extraction of the residue in tetrahydrofuran indicated that over 90% of the PPF was crosslinked over the range of PPF/VP ratios explored, but that the fraction of VP used in formation of crosslinks depended linearly on the PPF/VP ratio. Kinetic analysis of these data suggests that k'pp/kpf (the reactivity ratio) was approximately 2.0 where k'pp is the rate constant for the addition of VP radical to VP monomer leading to formation of poly(vinyl pyrrolidone), and kpf is for the addition of VP radical to PPF unsaturation.

Biocompatible Materials↗

Dye incorporation to enhance the laser ablation of standard and reduced-modulus bone cements.

Laser ablation of acrylic bone cement is an alternative method of cement removal that can be used during revision arthroplasty of cemented implants. This study investigated the feasibility of using a continuous-wave Argon ion laser (wavelength = 514 nm) with the addition of methylene blue or red dye no. 13 to enhance the ablation of two types of bone cements: polymethylmethacrylate and polybutylmethylmethacrylate. Six cement/dye combinations were studied while power (0.5, 0.75, and 1.0 W) and exposure times (30, 45, 60, and 90 seconds) were varied. The Argon laser was unable to ablate undyed polymethylmethacrylate or polybutylmethylmethacrylate. However, ablation was shown for both cements with either dye. The red dye had a stronger absorption peak at 514 nm than did the blue dye. Statistically larger ablation areas were seen for red polymethylmethacrylate than for blue polymethylmethacrylate (p < 0.013) at all levels tested. Ablation areas were larger in red than in blue polybutylmethylmethacrylate cement. Blue polybutylmethylmethacrylate cement produced larger ablation areas than did blue polymethylmethacrylate cements at all energy levels tested, with smaller surrounding damage areas. Red polybutylmethylmethacrylate cement also produced larger ablation areas than did red polymethylmethacrylate cement (at 0.75 and 1.0 W), again with smaller damage areas. Damage zones were smallest in red polybutylmethylmethacrylate cements at all test levels. These results suggest that, by using dyes to selectively alter the absorption characteristics of bone cement, laser ablation can be an effective method for cement removal. Changes in the chemical structure of the cement can also influence the response to laser treatment. Furthermore, the absorption spectra of the bone cement can be altered to maximize energy absorption at a wavelength that is not absorbed by bone tissue; this potentially minimizes damage to bone during revision surgery.

Arthroplasty↗