Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “BIOPSIES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Diagnosis for interstitial lung disease in patients with acquired immunodeficiency syndrome (AIDS): a prospective comparison of bronchial washing, alveolar lavage, transbronchial lung biopsy, and open-lung biopsy.

This study was undertaken to compare prospectively the diagnostic yield of the various bronchoscopic techniques with that of open-lung biopsy for interstitial lung disease in patients with acquired immunodeficiency syndrome (AIDS). Under general anesthesia, 15 patients sequentially underwent bronchial washing, transbronchial lung biopsy, alveolar lavage, and open-lung biopsy in the same segment of lung. Of nine patients with Pneumocystis carinii, seven were diagnosed by means of the transbronchial lung biopsy, eight by the open-lung biopsy, and all nine by alveolar lavage. Of the six patients with cytomegalovirus, five were diagnosed by the open-lung biopsy, five by the transbronchial lung biopsy, and three by alveolar lavage. The sensitivities of the procedures for identifying infection were washings (15%), transbronchial lung biopsy (50%), alveolar lavage (73%), and open-lung biopsy (88%). Combined, transbronchial lung biopsy and alveolar lavage showed a diagnostic yield (85%) for infections comparable to that of open-lung biopsy (88%), thereby obviating the need for open-lung biopsy for such diagnoses. However, open-lung biopsy was the only procedure that diagnosed Kaposi's sarcoma in lung.

Acquired Immunodeficiency Syndrome↗

Biopsy protocol stability in a three-dimensional model of prostate cancer: changes in cancer yield after adjustment of biopsy positions.

OBJECTIVES: Transrectal ultrasound-guided prostate biopsies are often taken according to a systematic, standardized schedule. The diagnostic stability of this system was evaluated by moving the biopsies in a three-dimensional (3D) model. METHODS: A computerized 3D reconstruction was made from each of 75 radical prostatectomy specimens. Simulated core biopsies imitated a standardized 10-biopsy protocol, including sextant biopsies. In total, 30,000 biopsies were generated by moving the standardized biopsies 1, 2, 3, and 4 mm (parallel needle shifts) or 5 degrees, 10 degrees, 15 degrees, and 20 degrees(rotation of the needle tip) in a random direction. RESULTS: The diagnosis of the individual biopsy changed from cancer to benign or vice versa in 4.9% to 1 5.7% after 1 to 4-mm parallel needle shifts and 2.0% to 7.5% after 5 degrees to 20 degrees rotations. The corresponding figures for the final diagnosis of the 10-biopsy set were 0.8% to 9.6% and 0.5% to 3.2%. Transition zone biopsies containing cancer changed to benign more often than the other biopsies (P <0.001). Parallel needle shifts of 2 mm changed the diagnosis more often than the 15 degrees rotation (9.4% and 5.9%, respectively, P <0.001), although conveying the same overall needle shift. CONCLUSIONS: The cancer yield of prostate biopsies is influenced even by small changes in needle positions. The transition zone biopsies are most likely to change from cancer to benign when moved. Changing the insertion point of the needle has a higher impact on cancer yield than rotating the tip.

Adult↗

The use of the automatic core biopsy system in percutaneous renal biopsies: a comparative study.

We describe our experience with the use of the automatic core biopsy system for percutaneous renal biopsy and compare this with our experience with a standard biopsy needle. Three hundred twenty-three biopsies were performed between June 1983 and January 1993. From June 1983 through October 1990, 232 biopsies were performed with the use of a standard biopsy needle (Tru-cut needle; Travenol Laboratories, Deerfield, IL) and from November 1990 through January 1993, 91 biopsies were conducted with the use of the automatic core biopsy system (Biopty gun and needle; C.R. Bard, Inc, Covington, GA). Biopsies performed prior to January 1990 were reviewed retrospectively, while those performed after January 1990 were reviewed in a prospective manner. The primary indications for renal biopsy were to evaluate proteinuria (48.9%) and renal manifestations of systemic lupus erythematosus (26.0%). The two groups of patients were similar with respect to sex, age, serum creatinine, and coagulation parameters. Material for light microscopy, immunofluorescence microscopy, and electron microscopy was obtained in 98.9%, 98.9%, and 97.8% of cases, respectively, with the use of the automatic core biopsy system, and these values did not differ significantly from those with the use of the standard needle (99.6%, 96.1%, and 97.8%). Significantly more glomeruli were obtained by light microscopy per biopsy specimen with the use of the automatic core biopsy system versus the standard needle (28 +/- 15 and 21 +/- 13, respectively; P < 0.0001). Complications were assessed and separated by severity. Total complications were observed in 13 patients (14.3%) with the automatic core device and in 31 patients (13.4%) with the standard needle.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Evaluation of a breast biopsy phantom for learning freehand ultrasound-guided biopsy of the liver.

RATIONALE AND OBJECTIVES: We evaluated whether a breast biopsy phantom device would aid in the development of skills in freehand ultrasound liver biopsy. METHODS: Three radiologists who were inexperienced in freehand biopsy of the liver were observed. Each radiologist was timed and scored during attempts to biopsy lesions created in a beef liver. The time required for biopsy and the success of each pass was recorded. A commercially available breast biopsy phantom was then used by each of these radiologists during two 20-min practice sessions. Posttraining testing on the beef liver was performed in the same manner as pretraining testing. RESULTS: Freehand biopsy practice using the breast biopsy phantom resulted in a reduction in the mean time required for biopsy from 32 to 17 sec. Each of the three subjects reduced the mean time required for successful biopsy after training using the breast biopsy phantom. The total number of lesions missed was reduced from 14 of 43 to 0 of 45. CONCLUSION: Practice using the ultrasound breast biopsy phantom improves performance in freehand ultrasound biopsy of the liver.

Animals↗

Transjugular liver biopsy with an automated trucut-type needle: comparative study with percutaneous liver biopsy.

OBJECTIVE: Transjugular liver biopsy using the suction method usually produces small specimens with excessive fragmentation, hence the diagnosis adequacy of specimens and the clinical impact of performing the biopsy have been questioned. An alternative biopsy needle, the Quick-Core needle system, which uses an automated trucut-type mechanism, has been shown to produce non-fragmented tissue specimens. The aim of the present study was to evaluate the safety, adequacy and clinical impact of the transjugular liver biopsy by comparing it with the standard percutaneous liver biopsy. DESIGN: We recruited all patients who underwent liver biopsies by percutaneous or transjugular routes in the Department of Medicine, Princess Margaret Hospital, Hong Kong between January 1998 and December 1999. METHOD: We recorded demographics and clinical features of patients, indications and complications, and the clinical impact of the liver biopsy procedure. All liver biopsy specimens were reviewed by the histopathologist, who was blinded to the approach of taking the biopsy. All variables between patients undergoing transjugular and percutaneous liver biopsies were compared. RESULTS: During the study period, 50 percutaneous and 18 transjugular liver biopsies were performed. All transjugular liver biopsies were performed successfully with adequate tissue for diagnosis. Although specimens obtained by the transjugular technique tended to be shorter (10 mm v. 18 mm by the percutaneous approach, P < 0.001), the presence of fragmentation was similar to that in biopsies obtained by the percutaneous approach. Respectively, 100% and 98% of specimens obtained by the transjugular and percutaneous approaches were considered to be adequate for histological assessment. The clinical impact of transjugular and percutaneous liver procedures was comparable (89% v. 76%, P = 0.25). CONCLUSION: Specimens obtained by a transjugular automated trucut needle are sufficient for histological assessment, and carry clinical impact in patient management.

Adult↗

A nomogram for predicting a positive repeat prostate biopsy in patients with a previous negative biopsy session.

PURPOSE: Although prostate cancer is found in about 30% of patients at the initial biopsy session, there is a need to identify those with a negative result but who are at high risk. Although individual risk factors have been found to be associated with cancer, patient counseling requires the integration of multiple risk factors to obtain a prediction for the individual. MATERIALS AND METHODS: We studied 343 patients with at least 1 initial negative biopsy who were tested from August 1999 to September 2001. At each biopsy session we recorded patient age, family history of prostate cancer, serum prostate specific antigen (PSA), PSA slope, digital rectal examination findings, months from the initial biopsy session, cumulative number of negative cores previously obtained, and history of high grade prostatic intraepithelial neoplasia or atypical small acinar proliferation. Through Cox regression analysis we determined the association of each variable with time to a positive biopsy. A nomogram was constructed using all variables and discrimination was calculated as the concordance index. RESULTS: There were 661 biopsy sessions. A mean of 2.9 biopsy sessions were performed per patient and a mean of 9.15 cores were obtained per biopsy session for a mean of 25.2 per patient. Overall 20% of patients had cancer at the second biopsy session. The cumulative number of negative cores obtained, PSA slope, history of high grade prostatic intraepithelial neoplasia and history of atypical small acinar proliferation were associated with repeat biopsy findings (all p <0.05). A nomogram was constructed that had a concordance index of 0.70, which was greater than that of any single risk factor. CONCLUSIONS: We created a nomogram that predicts a positive biopsy after a previous negative biopsy session. It provides a wide range of probabilities for cancer and may improve clinical judgment before the decision to repeat biopsy.

Adult↗

Needle liver biopsy in thalassaemia: analyses of diagnostic accuracy and safety in 1184 consecutive biopsies.

We report the reliability and safety of percutaneous liver biopsy in the evaluation of hepatic iron loading and histology in patients with homozygous beta-thalassaemia prior to and in serial biopsies following allogeneic bone marrow transplantation for this disorder. 501 thalassaemic patients aged 11 +/- 4.5 years (range 1-32 years) underwent 1184 consecutive percutaneous liver biopsies without ultrasound guidance. Overall, 81% of biopsies were evaluable for histological examination and grading of iron. The adequacy of liver biopsy specimens increased with patient age: evaluable specimens were obtained in 73% of patients < 5 years of age and in 86% of samples in patients aged > 15 years. The degree of iron overload and fibrosis in each biopsy was reported separately by at least two pathologists who did not know the clinical status of each patient. In 103 biopsies, iron grade by light microscopy corresponded to an iron concentration varying between a mean of 32.46 +/- 14 mumol/g dry weight liver tissue for iron stores graded by light microscopy as absent to 417.6 +/- 150 mumol/g dry weight liver tissue for stores graded as severe. The fibrosis score of multiple samples of liver obtained at autopsy within 100 d of the percutaneous biopsy in 41 patients who died following BMT correlated perfectly with that of the first sample in > 60% biopsies; in most of the discordant cases fibrosis had been underestimated in the percutaneous biopsy. Liver biopsy demonstrated evidence of chronic hepatitis in 30% of patients with normal transaminase and in 57% of patients with transaminase within twice the normal range. Liver biopsy was complicated in six patients (0.5%) by haemoperitoneum, periocholecystic haematoma, kidney haematoma, or bile peritonitis; no complication was fatal. These data demonstrate that percutaneous liver biopsy provides reliable information regarding liver iron and histology in homozygous beta-thalassaemia with an extremely low risk of complications.

Adolescent↗

MRI-guided breast biopsy: clinical experience with 14-gauge stainless steel core biopsy needle.

OBJECTIVE: Core needle biopsy has proven advantages for wire localization and excision; however, MRI-guided core biopsy has been limited by less satisfactory sampling efficiency and less availability of MRI-compatible biopsy needles. We evaluated the feasibility and diagnostic yield of MRI-guided biopsy using 14-gauge stainless steel core biopsy needles and MRI-compatible coaxial sheaths in a closed 1.5-T scanner. MATERIALS AND METHODS: Thirty-five consecutive breast biopsies performed in 29 women between March 2001 and August 2002 were retrospectively reviewed. For each procedure, an MRI-compatible sheath was placed under MRI guidance using a dedicated breast coil and biopsy guidance system. With the patient out of the magnet, a 14-gauge steel core biopsy needle was used to obtain multiple samples. Lesion characteristics, including size, morphology, and enhancement, were recorded. Histology of all the lesions was obtained; and surgical, imaging, or clinical follow-up was performed. RESULTS: Targeted masses and enhancing foci ranged from 3 to 17 mm. Regional enhancement ranged from 14 to 70 mm. Thirty-four of the 35 biopsies were technically successful. Histology revealed malignancy in eight lesions (23%), atypical ductal hyperplasia in five lesions (14%), and benign entities in 21 lesions (60%). Surgery confirmed all eight core biopsies with malignant findings. Two of five lesions with atypical ductal hyperplasia were upgraded to malignancy after surgery. CONCLUSION: This new method of MRI-guided breast biopsy with a 14-gauge stainless steel core biopsy needle and a closed 1.5-T MRI scanner is feasible, safe, and effective and produces satisfactory diagnostic yield. This method offers an alternative to MRI-guided wire localization and to MRI-guided core biopsy with nonferrous needles.

Adult↗

[Ultrasound-guided biopsy: screening of prostate cancer with a single set of 14 systematic biopsies].

Standard sextant prostate biopsy may underestimate cancer in men in whom clinical finding and transrectal ultrasound are negative and prostate-specific antigen (PSA) value suspicious for localized prostate cancer (4-10 ng/ml). We describe our experience with a 14 systematic multisite biopsy scheme to detect carcinoma of the prostate (stage T1c). Between January 1999 and February 2000, a total of 177 consecutive patients (mean age 64.1 +/- 7.7 years) underwent systematic transrectal ultrasound (TRUS) guided biopsy for normal digital rectal examination, normal TRUS and abnormal prostate specific antigen 4 ng/ml or greater (4-13 ng/ml). Fourteen core/patient were obtained not depending on prostate size. Biopsies were obtained from conventional sextant biopsies (6 core) and 3 alternate sites which included: the right and left extreme lateral peripheral zone between anterior tissue and posterior gland base (2 core); the right and left transition zone, immediately adjacent to the urethra anterior and posterior (4 core) and the right and left central gland in the mid zone typical of benign prostatic hyperplasia (BPH) (2 core). All specimens were separated for specific location identification. Adenocarcinoma was identified in 61 patients (34.46%). Traditional sextant biopsies showed 23 patients (37.7%) with positive core to detect cancer, while a sextant regimen incorporating lateral peripheral zone biopsies and transitional zone detected 19 cancer (31.1%). The combination of lateral peripheral and transitional zone alone detected cancer in 19 patients. No cancer was detected in central gland. The lateral peripheral zone was the most frequently positive site biopsy with 11 patients (57.9%) followed by the transitional zone with 8 patients (42.1%) in the group of the alternate biopsies sites. Complications of extensive biopsy included hematuria, hematospermia and limited rectal blending in 95% of patients; 1 case of fever (> 38.5 degrees C) for 3 days. Biopsies of the alternate sites are easy, feasible and reproducible. This strategy enhance prostate cancer detection of a 30% compared to conventional sextant biopsies alone. In conclusion, the 6 systematic biopsy of the peripheral zone are inadequate and a minimum of 12 with extensive core in peripheral and transitional zone should routinely be performed to detect a more significant number of men with prostate cancer at stage T1c.

Biopsy↗

Atypical small acinar proliferation (ASAP) on extended prostatic biopsies: predictive factors of cancer detection on repeat biopsies.

OBJECTIVE: To evaluate the clinical and histopathologic factors that may help to predict cancer detection by means of extended repeated prostate needle biopsies in patients with Jumma atypical small acinar proliferation (ASAP) results on initial prostate biopsy. MATERIALS AND METHODS: From 1998 to September 2003, 105 out of 121 (86%) patients with a diagnosis of ASAP after a first set of 10 to 12 systematic biopsies, were rebiopsied using the same technique plus additional biopsies on the ASAP site (mean number of repeat biopsy samples, 12.6). The median time until a second and third biopsy was 7.04 months (95% confidence interval [CI], 5.5-8.5), and 13.3 months (95% CI, 8.8-17.7; 19 patients), respectively. Each histological slide was reviewed blindly by a single experienced pathologist (M.F) who differentiated highly suspicious (ASAPH) and not highly suspicious (ASAPB) lesions for cancer. RESULTS: On initial biopsy, a concomitant HGPIN was present in 18 patients (17%) with ASAP The overall cancer detection rate in those who underwent two or three sets of biopsies was 39% (41/105); it was 35% (37/105) and 21% (4/19) in second and third biopsies, respectively. The overall cancer detection rate was higher in patients who had ASAP associated with HGPIN (50%) compared with patients who had isolated ASAP (37%) (p = 0.3). Statistical analysis showed that levels of prostate-specific antigen (PSA), PSA density, prostatic volume, digital rectal examination results, transrectal ultrasound findings, time until rebiopsy (less vs. more than 6 months), and histological level of suspicion were not significant predictors of prostate cancer at the time of rebiopsy. In particular, the cancer detection rate was not significantly higher in patients with ASAPH than those with ASAPB (49% vs. 33%, respectively; p = 0.11). In a univariate analysis, the mean prostate volume was statistically different in patients with cancer compared with those without (56.4 +/- 6.3 and 78.9 +/- 5.3 respectively; p = 0.009), but only in the group of patients who had isolated ASAP In these patients, the rate of cancer detection was significantly higher in patients who had a prostatic volume less than 60 mL (56%) than in patients with a prostatic volume greater than or equal to 60 mL (27%) (p = 0.03). CONCLUSIONS: Patients with an initial ASAP diagnosis after extended biopsies had an overall cancer detection rate less than 40% after two sets of extended biopsy. ASAPH lesions did not indicate a significantly higher risk of cancer than ASAPB lesions on repeated extended biopsies. Despite the extended rebiopsy plus the additional biopsies targeted to the ASAP lesion, the detection rate was lower for patients with a larger prostate than those with a smaller prostate.

Aged↗

Cancer detection with TRUS-guided 10-core biopsy of the prostate. an institutional assessment at the first, repeated and surgical specimen biopsy.

OBJECTIVES: We retrospectively investigated the results of the 10-core scheme that our institute has adopted for three years. The aim of this study is to evaluate the cancer detection rate in different sets of biopsies (first, second, third and surgical specimen biopsy). MATERIAL AND METHODS: Patients with clinical suspicion of prostate cancer based on abnormal digital rectal examination, increase of PSA or hypoechoic lesion at transrectal ultrasound were subjected to a 10-core biopsy. Ten biopsies were taken following the traditional sextant technique and 4 more biopsies were obtained from the lateral peripheral zone. In addition, a group of 19 specimens of retropubic radical prostatectomy were biopsied immediately following surgery. RESULTS: Of 664 patients 247 (37.2%) were positive for prostate cancer at first biopsy. Eighty-one out of 664 patients were subjected to a second biopsy for persistent elevation or increasing of PSA, or in case of tumor associated histological findings such as high PIN and ASAP. The cancer detection rate in this group was 19.8% (16/81). Of the remaining 65 patients who were negative at second biopsy, 12 received a third biopsy for persistent clinical suspect of cancer, and 2 were positive (16.7%). In 19 surgical specimens, 14 biopsies were confirmed positive and 5 were negative (73.7%). CONCLUSIONS: The extended biopsy such as the 10-core scheme showed to be a reliable protocol, taking an adequate cancer detection rate either at first or repeated biopsy with no increase in morbidity.

Aged↗

[Studies on multiple mucosal biopsy in patients with bladder cancer. 1. Evaluation of the results of multiple mucosal biopsy in patients with bladder cancer and in vivo methylene blue staining].

Between March, 1980 and July, 1984, 165 multiple mucosal biopsies were performed in 111 patients with bladder cancer. Of these 165 multiple mucosal biopsies, 87 were performed in new cases and 78 in recurrent cases: 147 were performed under in vivo staining with intravesical methylene blue. Before endoscopic tumor resection, biopsies were taken with a flexible cup biopsy forceps from non-tumorous urothelium lateral to the ureteral orifices, in the midline posteriorly, from both lateral wall and bladder neck, adjacent to the tumor and from the tumor itself. Histological abnormalities in this paper indicate transitional cell carcinoma, microinvasion of carcinoma in situ, carcinoma in situ, dysplasia and hyperplasia. In the total 955 biopsy specimens, transitional cell carcinoma was found in 45 (4.7%), microinvasion of carcinoma in situ in 30 (3.1%), carcinoma in situ in 55 (5.8%), dysplasia in 27 (2.8%), hyperplasia in 141 (1.5%), squamous metaplasia in 4 (0.4%), proliferative cystitis in 58 (6.1%), inflammation in 230 (24.1%) and normal epithelium in 492 (51.5%). The frequency of histological abnormalities in biopsied specimens was 14.8% in new cases, 21.1% in recurrent cases, the difference being statistically significant (P less than 0.01). Transitional cell carcinoma and dysplasia were more common in mucosal biopsies of recurrent cases than those of new cases (P less than 0.001, P less than 0.05). The frequency of histological abnormalities was 11.5% in 836 biopsy specimens from cystoscopically normal-looking mucosa, while 65.5% in 119 biopsy specimens from grossly abnormal mucosa, the difference being statistically significant (P less than 0.001). Of histological abnormalities, transitional cell carcinoma, microinvasion of carcinoma in situ and carcinoma in situ were more common in biopsy specimens from grossly abnormal mucosa than those from normal-looking mucosa (P less than 0.001). The frequency of histological abnormalities in mucosal biopsy was 11.4% in patients who exhibited a single tumor, and 26.7% in those with multiple tumors, the difference being significant (P less than 0.005). Biopsies of mucosa adjacent to a visible tumor were abnormal most frequently (26.9%), while those taken lateral to the ureteral orifices, from the midline posteriorly and from both lateral wall revealed a slightly lower rate of abnormal findings. The frequency of histological abnormalities in mucosal biopsy was 7.7% in patients with G1 tumor, 15.8% in those with G2 tumor and 36.0% in those with G3 tumor. The histological abnormalities increased with the increase in the grade of main tumor; this correlation was statistically significant (P less than 0.001).(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Strategy for repeat biopsy of patients with prostatic intraepithelial neoplasia detected by prostate needle biopsy.

PURPOSE: We evaluated the strategy for repeat biopsy of patients with prostatic intraepithelial neoplasia without concurrent carcinoma detected on prostate needle biopsy. MATERIALS AND METHODS: Of 1,275 consecutive patients undergoing prostate needle biopsy 61 were identified with prostatic intraepithelial neoplasia but without concurrent prostate carcinoma. Of the 61 patients 53 had undergone repeat biopsy. The medical records, transrectal ultrasound, and operative and pathological reports of these patients were reviewed. RESULTS: Repeat biopsy was done in 53 patients with prostatic intraepithelial neoplasia, yielding carcinoma in 15, prostatic intraepithelial neoplasia without carcinoma in 8 and benign tissue in 30. The yield of carcinoma from repeat biopsy of a prostatic intraepithelial neoplasia site was 8.3% (7 of 84 sites). A total of 18 sites of carcinoma was detected by repeat biopsy of a previous random biopsy site (8), a prostatic intraepithelial neoplasia site only (5), a transrectal ultrasound nodule (3), a palpable nodule and prostatic intraepithelial neoplasia site (1), and a transrectal ultrasound nodule and prostatic intraepithelial neoplasia site (1). Carcinoma was as frequently detected by repeat biopsy of a prostatic intraepithelial neoplasia site (6 patients) as by random repeat biopsy (6 patients). CONCLUSIONS: Repeat prostate needle biopsy of patients with prostatic intraepithelial neoplasia should include random repeat biopsy and repeat biopsy of transrectal ultrasound abnormalities as well as previous sites of prostatic intraepithelial neoplasia.

Adenocarcinoma↗

Routine transition zone and seminal vesicle biopsies in all patients undergoing transrectal ultrasound guided prostate biopsies are not indicated.

PURPOSE: Transrectal ultrasound guided biopsies of the transition zone and seminal vesicles have been useful in select patients. More widespread use of these additional biopsies has been proposed. The efficacy of routine transition zone and seminal vesicle biopsies was examined. MATERIALS AND METHODS: From January 1988 to October 1994, 736 transrectal ultrasound guided systematic sextant biopsies were performed. From October 1994 to July 1995, 161 consecutive patients underwent transrectal ultrasound with systematic sextant, transition zone and seminal vesicle biopsies. RESULTS: Of the 736 patients undergoing only sextant biopsies 309 (42.0%) had cancer and 24 (3.3%) required repeat biopsy, compared to 55 (34.2%) and 4 (2.5%) of 161 undergoing combined sextant, transition zone and seminal vesicle biopsies. Prostate cancer was found only in the systematic sextant biopsies in 43 of the former 55 patients (78.2%), and in the transition zone and systematic sextant biopsies in 11 (20.0%). One patient (1.8% of patients with cancer or 0.6% of all 161 patients) had cancer in only the anterior biopsies and 6 (10.9 and 3.7%, respectively) had cancer involving the seminal vesicles. CONCLUSIONS: Routine transition zone and seminal vesicle biopsies in all patients undergoing transrectal ultrasound guided systematic sextant biopsies are not warranted.

Aged↗

[US-guided core biopsy of the breast with an automated biopsy gun: comparison with an aspiration core needle device].

To evaluate the efficacy of an automated Tru-cut type of biopsy gun in US-guided breast biopsy, we performed 162 breast biopsies in 148 patients using an 18 gauge short-throw (1.1cm excursion) Tru-cut-type biopsy gun (Ace-cut needle). The results of the series were compared with another series of aspiration core biopsies, which were performed on 113 breast lesions in 112 patients using an 18 gauge Sure-cut needle. The results of the two series were correlated with the diagnoses made at surgery or clinical follow-up. Sensitivity, specificity, and accuracy for the automated biopsy gun were 89.2%, 94.9%, and 92.7%, and for the Sure-cut needle, 75.0%, 78.6%, and 77.5%, respectively (p < 0.01 for specificity and accuracy, by chi 2 test). There were no serious complications. The diagnostic surgical biopsy to operated cancer ratios in 1991 (without core biopsy), 1993 (with aspiration core biopsy), and 1995 (with automated core biopsy) were 2.9 (46/10), 2.0 (30/17), and 0.5 (12/24), respectively. We concluded that US-guided breast biopsy with an automated biopsy gun is a safe and highly accurate method, and could replace the diagnostic surgical biopsy.

Biopsy, Needle↗

Use of new automated biopsy device for percutaneous testicular biopsy. A preliminary clinical experience.

Testicular biopsy is indicated in the azoospermic patients to determine if the cause of azoospermia is ductal obstruction or testicular pathology and in certain patients who have severe oligozoospermia. The technique traditionally used is an open testicular biopsy. New Automated Biopsy Device has been used successfully for renal diseases. This instrument is now used by the urologist for transrectal prostate biopsy. The aim of this study was to evaluate whether percutaneous testicular needle biopsy with new automated device can replace open testis biopsy or not. 90 testes of 48 patients between 22 and 43 years olf underwent percutaneous testicular biopsy with a new 18-gauge automated biopsy device. Adequate samples were recovered from 90% cases (average 24.77 tubule sections per testis). When needle biopsy and open biopsy samples were compared in 30 testes of 15 patients, complete agreement was obtained in 93%, whereas slight differences in 7%. These results show that percutaneous needle biopsy with new automated systems is cost-effective, quick, safe, repeatable, relatively painless and effective way to obtain largest possible cores through full cut technique. No serious complications were encountered during or after the procedure. The diagnosis were found to be comparable to those obtained by open biopsy. For these reasons, it is concluded that this new technique can replace the open biopsy.

Adult↗

[Stereotactic biopsy for non-palpable breast lesions: evaluation and choice of minimal invasive and excisional biopsy].

OBJECTIVE: To evaluate three biopsy methods which are currently used in stereotactic breast biopsy. METHODS: A total of 361 cases of stereotactic breast biopsies were carried out since 2000, including 73 cases of true cut core needle biopsies (ST-CNB), 74 cases of vacuum assisted biopsies (ST-VAB) and 214 cases of excisional biopsies. After medium follow-up time of 18 months (6 to 66 months), the accuracy as well as the clinical benefits of the three stereotactic biopsy procedures were analyzed retrospectively. RESULTS: The cancer miss rate of stereotactic wire localized excisional biopsy, ST-CNB and ST-VAB is 0, 2.7% and 0 respectively. Under-estimate rate of minimal invasive biopsy was 33% in atypical ductal hyperplasia (ADH) and 53% in ductal carcinoma in situ (DCIS). The minimal invasive procedure is superior to surgical procedure in terms of operation time, breast cosmetic outcome and complications, etc. Furthermore, 69% of the surgeries for suspicious lesion were waived. CONCLUSIONS: Stereotactic minimal invasive breast biopsy, especially ST-VAB, is an accurate, safty and convenient diagnosis technique and could be considered as the first line choice for mammographic moderate suspicious breast lesions (BIRADS-4). However, further excisional biopsy is recommended for atypical hyperplasia. Stereotactic excisional biopsy could be directly used for diagnosis of mammographic highly suspicious breast lesions (BIRADS-5).

Biopsy↗