Critical evaluation of the factorial and heart-rate recording methods for the determination of energy expenditure of free-living elderly people.

The aim of the present study was to validate against the doubly-labelled water (DLW) technique the factorial method and the heart rate (HR) recording method for determining daily energy expenditure (DEE) of elderly people in free-living conditions. The two methods were first calibrated and validated in twelve healthy subjects (six males and six females; 70.1 (SD 2.7) years) from open-circuit whole-body indirect calorimetry measurements during three consecutive days and during 1 d respectively. Mean energy costs of the various usual activities were determined for each subject using the factorial method, and individual relationships were set up between HR and energy expenditure for the HR recording method. In free-living conditions, DEE was determined over the same period of time by the DLW, the factorial and the HR recording methods during 17, 14 and 4 d respectively. Mean free-living DEE values for men estimated using the DLW, the factorial and the HR recording methods were 12.8 (SD 3.1), 12.7 (SD 2.2) and 13.5 (SD 2.7) MJ/d respectively. Mean free-living DEE values for women were 9.6 (SD 0.8), 8.8 (SD 1.2) and 10.2 (SD 1.5) MJ/d respectively. No significant differences were found between the three methods for either sex, using the Bland & Altman (1986) test. Mean differences in DEE of men were -0.9 (SD 11.8) % between the factorial and DLW methods, and + 4.7 (SD 16.1) % between the HR recording and DLW methods. Similarly, in women, mean differences were -7.7 (SD 12.7) % between the factorial and DLW methods, and + 5.9 (SD 8.8) % between the HR recording and DLW methods. It was concluded that the factorial and the HR recording methods are satisfactory alternatives to the DLW method when considering the mean DEE of a group of subjects. Furthermore, mean energy costs of activities calculated in the present study using the factorial method were shown to be suitable for determining free-living DEE of elderly people when the reference value (i.e. sleeping metabolic rate) is accurately measured.

Aged↗

Brief Rorschach records with children and adolescents.

In order to determine the frequency with which children and adolescents give brief Rorschach (R less than 14) records and to test the hypothesis that brief records represent a resistance to testing, the psychological evaluations of 439 admissions to an inpatient unit were reviewed. Of the records reviewed, 16.6% were found to contain less than 14 responses. When the complete test protocol of those subjects who provided brief records were compared with those of a matched group, it was found that the group with brief records failed to complete the other parts of the evaluation significantly more often than did those subjects who did not give brief records. There was no significant difference between the two groups on IQ scores or on self-report scores of depression, anxiety, and social desirability. Result are interpreted as supporting Exner's (1988) hypothesis that brief records represent a form of resistance to being tested.

Adolescent↗

Recording of ENGs from the nerves innervating the pancreas of a dog during the intravenous glucose tolerance test.

Electroneurograms (ENGs) from the vagus nerve (VN), the splanchnic nerve (SN) and the pancreatic nerve (PN) innervating the pancreas of a dog, were recorded with chronically implanted 33-electrode spiral cuffs (cuff) before and after the pancreas were stimulated with intravenously (i.v.) administered glucose. In the cuffs platinum electrodes were arranged in three parallel spiral groups containing 11 electrodes on the inner surface. The cuffs had an inner diameter of 2 mm and a length of 18 mm. In a two-year study, the cuffs were implanted into two Beagle dogs and were also used for pancreatic stimulation, although this is not described in this paper. In the VN, the cuff was installed on the nerve at the neck, whilst in the SN, the cuff was installed on the nerve before the celiac ganglion, and in the PN, the cuff was installed on the nerve just before it enters the pancreas. Six months after implantation, when the model of interpretation of the results was developed, three recordings of ENG in each animal were conducted. The first one was conducted in the unstimulated pancreas while the second and the third were conducted 1 and 8 min after a known amount of glucose was i.v. administered. Since the results obtained in both animals were actually quite similar, we present the results obtained in one animal. To evaluate the changes in superficial activity of the nerves, elicited by the administration of glucose, the power spectra corresponding to ENGs, recorded from the nerves before and after the administration of glucose, were integrated within the band of frequencies ranging from 1 to 5 kHz. Accordingly, the magnitude of the integrated power spectrum (MIPS), corresponding to the ENG recorded from the SN before administration of glucose, was 2.863 au. One minute after glucose was administered the value fell to 2.795 au while 8 min after the administration the value returned to 2.8 au. The MIPS corresponding to the ENG recorded from the PN before the administration of glucose was 3.236 au. One minute after the administration the value fell to 2.901 au while 8 min after the administration the value rose to 3.009 au. The MIPS, corresponding to the ENG recorded from the VN before the administration of glucose, was 3.656 au. One minute after the administration the value fell to 3.565 au. Eight minutes after the administration the value rose to 3.689 au. The results show that 1 min after glucose was administered superficial activity in all three nerves was reduced while 8 min after administration the activity in the nerves returned to the same level of activity before the glucose was administered. This information could be effectively used in a further study of pancreatic innervation and its function. Moreover, the results suggest that cuffs could also be useful in recording the ENGs from other nerves of the autonomic nervous system that innervate various glands and internal organs.

Animals↗

The use of an electronic patient record system to identify advanced cancer patients and antidepressant drug use.

PURPOSE: Psychiatric morbidity is common in cancer patients toward the end of life. In this study, we demonstrate the use of an electronic patient record system to identify patients with advanced cancer, and then analyze practice patterns regarding the use of antidepressants. PATIENTS AND METHODS: Using electronic patient records from January 1986 to December 1996, we identified 17,476 patients with possible cancer. Patients were identified by virtue of having any one of eight markers. We used an iterative process to modify the specificity of these markers, and an advanced cancer cohort was assembled consisting of 1185 patients. RESULTS: A random sample of 200 written medical records were reviewed, of which 157 records (78.5%) were retrieved. Extracted information was reviewed by an oncologist, and patients were classified as follows: (1) no evidence of cancer; (2) evidence of cancer with an expected survival of less than or equal to 24 months; or (3) evidence of cancer with an expected survival of more than 24 months. Overall, 86% of the advanced cancer sample assembled from electronic records was correctly classified as advanced cancer by the review of the written records. Overall, 16% of all 1185 patients with advanced cancer were exposed to at least one antidepressant, with 3% of patients exposed to a selective serotonin-reuptake inhibitor, 10% exposed to a tricyclic antidepressant at a dose of greater than 25 mg, and 4% exposed to a low dose of a tricyclic antidepressant. CONCLUSION: The electronic patient record can be used to assemble an advanced cancer cohort for the purpose of studying palliative care practice patterns. Antidepressants are seldom part of the palliative management of this population.

Journal Article↗

Comparison of energy expenditure estimates from doubly labeled water, a physical activity questionnaire, and physical activity records.

BACKGROUND: Various methods are used by epidemiologists to estimate the energy cost of physical activity; these include physical activity records and recalls. However, there is limited validation of these methods against the doubly labeled water technique for determining energy expenditure (EE). OBJECTIVE: We compared EE as estimated by indirect methods (physical activity records and recall questionnaires) used in epidemiologic studies with EE obtained from doubly labeled water (EE(DLW)) in free-living men. DESIGN: We determined EE(DLW), energy intake at weight maintenance, and EE from 7-d physical activity records (EE(Record)) and a 7-d physical activity recall questionnaire (EE(Recall)) in 24 men aged 41 plus minus 2.0 y ( plus minus SEM) with a body mass index (in kg/m(2)) of 25.1 plus minus 0.5. RESULTS: There was excellent agreement between EE(DLW) (13.27 plus minus 0.35 MJ/d) and energy intake (13.19 plus minus 0.36 MJ/d), with a difference of 0.5 plus minus 1.0% ( plus minus SE). The indirect measures of physical activity and EE were 14.17 plus minus 0.37 MJ/d for EE(Record) (difference from EE(DLW): 7.9 plus minus 3.2%) and 17.40 plus minus 1.45 MJ/d for EE(Recall) (difference from EE(DLW): 30.6 plus minus 9.9%). CONCLUSIONS: Seven-day physical activity records provide an acceptable estimate of EE in free-living adults compared with EE(DLW), but 7-d physical activity recalls have limited application to estimate daily EE. For optimal validity, the 7-d physical activity records require good subject compliance and the provision of careful instructions for their use.

Adult↗

Validation of dietary assessment methods in the UK arm of EPIC using weighed records, and 24-hour urinary nitrogen and potassium and serum vitamin C and carotenoids as biomarkers.

BACKGROUND: In the UK EPIC validation studies, the accuracy of several methods was assessed by comparison with to-day weighed records and the biomarkers, 24-hour urine nitrogen (N) and potassium (K), plasma carotenoids and plasma vitamin C. METHODS: Comparisons between methods were made on 156 women, studied over 1 year at 3-monthly intervals at home. On each of four occasions, volunteers completed 4 days of weighed records and provided two 24-hour urine collections and a fasting blood sample. RESULTS: In comparison with the 16 days of weighed records, a food frequency questionnaire (FFQ) yielded higher values mainly due to greater reported consumption of milk and of vegetables. A 24-hour recall was as good as the FFQ in placing individuals in the distribution of habitual diet from weighed records. Results obtained from a 7-day estimated record were closest to those obtained from the weighed record. Correlations between 24-hour urine excretion and dietary N intake from weighed records were high (0.78-0.87) as were those with estimated food diaries (0.60-0.70). Correlations between urine N and the FFQ and 24-hour recall were lower (0.10 to 0.27), but improved by energy adjustment using residuals for N and K which are correlated with total energy intake. Comparisons between dietary estimates and urinary K and serum carotenoids and vitamin C showed broadly similar results. Limited biomarker information amongst 200 UK EPIC participants supported the findings of the validation study. CONCLUSIONS: UK EPIC uses three methods (the 7-day diary, an improved FFQ, and the 24-hour recall) to assess diet. 93% of first food diaries are returned completed by participants. Repeated diaries are the main dietary assessment method for nested case-control analyses.

Aged↗

Releasing pre-adoption birth records: a survey of Oregon adoptees.

OBJECTIVE: In June 2000, Oregon implemented a citizen-initiated ballot measure that grants adult adoptees access to their birth records, which contain their birth parents' identifying information. Because other states are considering similar policy changes, the authors explored whether Oregon's new law is meeting the information needs of adoptees. METHODS: Birth records were abstracted for a 9% (221/2,529) random sample of adoptees who obtained their records from June 20, 2000, to July 20, 2000, to describe the population and the information they obtained. Telephone interviews documented their motivations, expectations, and whether they considered the birth record useful. RESULTS: The mean age of the adoptees was 41 years, 64% were female, and 97% were white. Virtually all received information about their birth mother; however, only one-third received information about their birth father. Of the 221 sampled, 123 (59%) participated in the telephone survey, 12 were ineligible, 84 could not be reached, and 2 refused. The most common motivations for requesting records were to find birth parents (29%) and to obtain medical information (29%). Twenty-nine percent received less information than they expected, with many expecting, but not receiving, birth father information. Thirty-three (47%) of the 70 adoptees who tried to find their birth mother were successful. The records were considered "very" useful by 52% of respondents, "somewhat" or "a little" useful by 42%, and "not at all" useful by 6%. CONCLUSIONS: The results indicate that many adoptees received less information than they expected, and many did not meet their goals of finding birth parents or obtaining medical information. Nonetheless, the majority considered their birth records useful and important.

Access to Information↗

Transient evoked otoacoustic emissions recorder using maximum length sequences as a function of stimulus rate and level.

OBJECTIVE: The recently developed technique of recording transient evoked otoacoustic emissions (TEOAEs) using clicks presented according to maximum length sequences (MLSs) enables very high stimulation rates to be used. The aim of this study was to provide normative data on the relationship between TEOAEs recorded conventionally (at 40 clicks/sec) and those recorded using the MLS technique (at 11 maximum rates between 100 and 5000 clicks/sec) to establish a baseline for future clinical studies. DESIGN: TEOAEs were recorded at 12 rates from 12 normally hearing adult ears at click levels decreasing in 5 dB steps from 68 dB peSPL. RESULTS: The morphology of the waveforms and the pattern of the input/output functions with latency were similar for conventional and MLS TEOAEs. The only major difference between TEOAEs recorded at the different rates was in their absolute amplitude. As the click rate was increased from 40 clicks/sec there was a reduction in amplitude that reached a near asymptote at approximately 1500 clicks/sec. When expressed as a percentage reduction in amplitude compared with that recorded at 40 clicks/sec, this MLS "rate effect" was independent of stimulus level over all but the lowest test level (38 dB peSPL SPL). CONCLUSION: Over a wide range of amplitudes of conventionally recorded TEOAEs (21 to 450 microPa for the 9 to 13 msec section of the otoacoustic emission), the mechanism involved in the MLS rate effect seems to act in a way that reduces the amplitude by an almost constant proportion, whatever its original size.

Acoustic Stimulation↗

Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential.

OBJECTIVE: This study outlines a series of experiments using the neural response telemetry (NRT) system of the Nucleus CI24M cochlear implant to measure the electrically evoked compound action potential (EAP). The goal of this investigation was to develop a protocol that allows successful recording of the EAP in a majority of CI24M cochlear implant users. DESIGN: Twenty-six postlingually deafened adults participated in this study. A series of experiments were conducted that allowed us to examine how manipulation of stimulation and recording parameters may affect the morphology of the EAP recorded using the Nucleus NRT system. RESULTS: Results of this study show consistent responses on at least some electrodes from all subjects. Cross-subject and cross electrode variations in both the growth of the response and the temporal refractory properties of the response were observed. The range of stimulus and recording parameters that can be used to record the EAP with the Nucleus NRT system is described. CONCLUSIONS: Using the protocol outlined in this study, it is possible to reliably record EAP responses from most subjects and for most electrodes in Nucleus CI24M cochlear implant users. These responses are robust and recording these responses does not require that the subject sleep or remain still. Based on these results, a specific protocol is proposed for measurement of the EAP using the NRT system of the CI24M cochlear implant. Potential clinical implications of these results are discussed.

Adult↗

A pressure-recording guide wire for measurements of trans-stenotic gradients in arteries. In vitro validation.

RATIONALE AND OBJECTIVES: A 0.018'' guide wire with a pressure sensor near the tip has been developed for measuring arterial trans-stenotic pressure gradients. The pressure-recording properties of this system in vitro are evaluated. METHODS: Static and dynamic tests were performed with five guide wires. Dynamic tests (step response and recordings of phase and frequency response) were performed with a pressure generator connected to a recording system and a spectrum analyzer. RESULTS: Zero drift at 3 hours ranged from -1.9 to 2.2 mmHg/hour. Sensitivity drift ranged from 0.3% to 2.1%/hour. Hysteresis ranged from 0.2% to 4.3% (mean 2.4%). Bending in arcs of 180 degrees with diameters < 4 cm changed sensitivity and zero pressure recordings in all guide wires. Dynamic recordings showed a slight undershoot and no oscillation. CONCLUSION: Static errors exceeded those of external pressure transducers for fluid-filled catheters, indicating suboptimal recordings of absolute pressures. However, the small size, and the good dynamic properties, make this pressure wire a promising device for recording trans-stenotic pressure gradients in arteries.

Arteries↗

Comparing cycling world hour records, 1967-1996: modeling with empirical data.

PURPOSE: The world hour record in cycling has increased dramatically in recent years. The present study was designed to compare the performances of former/current record holders, after adjusting for differences in aerodynamic equipment and altitude. Additionally, we sought to determine the ideal elevation for future hour record attempts. METHODS: The first step was constructing a mathematical model to predict power requirements of track cycling. The model was based on empirical data from wind-tunnel tests, the relationship of body size to frontal surface area, and field power measurements using a crank dynamometer (SRM). The model agreed reasonably well with actual measurements of power output on elite cyclists. Subsequently, the effects of altitude on maximal aerobic power were estimated from published research studies of elite athletes. This information was combined with the power requirement equation to predict what each cyclist's power output would have been at sea level. This allowed us to estimate the distance that each rider could have covered using state-of-the-art equipment at sea level. According to these calculations, when racing under equivalent conditions, Rominger would be first, Boardman second, Merckx third, and Indurain fourth. In addition, about 60% of the increase in hour record distances since Bracke's record (1967) have come from advances in technology and 40% from physiological improvements. RESULTS AND CONCLUSIONS: To break the current world hour record, field measurements and the model indicate that a cyclist would have to deliver over 440 W for 1 h at sea level, or correspondingly less at altitude. The optimal elevation for future hour record attempts is predicted to be about 2500 m for acclimatized riders and 2000 m for unacclimatized riders.

Acclimatization↗

Cardiac loop ECG recording: a new noninvasive diagnostic test in recurrent syncope.

The most crucial step in diagnosing syncope is determining whether or not an arrhythmia is the cause. A new recording device, the continuous cardiac loop ECG recorder, affords prolonged ambulatory monitoring and can capture the rhythm at the time of syncope. To determine the impact of cardiac loop ECG recorders in diagnosing syncope, we reviewed the records of the first 48 patients referred for cardiac loop recording because of unexplained syncope or presyncope. Previous cardiac studies were nondiagnostic in all patients. In 36% of these patients, loop recording definitively determined whether an arrhythmia was the cause of symptoms. Median duration of monitoring was 28 days, with an average charge of $180 per month. Cardiac loop ECG recording is a convenient, safe, inexpensive, and potentially highly effective means of diagnosing unexplained syncope.

Adolescent↗

Spine and scalp recordings as a function of intensity. A model for changes during spinal cord monitoring.

STUDY DESIGN: Spinal cord monitoring has used both spine and scalp recordings as indicators of spinal cord integrity. The relative merits of spine or scalp recordings to predict the quality of the afferent volley in the somatosensory pathway were addressed in this study by using various stimulus intensities as a way to model alterations of the size of the afferent volley. OBJECTIVES: The results were analyzed to determine the correlation of central recordings taken at the spine or scalp with peripheral recordings. SUMMARY OF BACKGROUND DATA: Spinal cord monitoring with somatosensory evoked potentials has been achieved with recordings of signals generated by either the spinal cord or the somatosensory cortex. Spine recordings are thought to be more stable, yet little evidence exists to document this statement. METHODS: Seven patients were studied in the course of standard intraoperative spinal cord monitoring. Responses were recorded at the popliteal fossa, thoracic epidural, cervical spine, and scalp to tibial nerve stimulation at intensities varying from 0.5 to 2.0 times muscle twitch threshold. RESULTS: Normalized amplitudes of the response at the popliteal fossa were used to reflect the magnitude of the afferent volley. The amplitudes of the popliteal fossa response showed a high correlation (r = 0.90) with normalized amplitudes of epidural and cervical spine responses and moderate correlation (r = 0.49) with normalized amplitudes of scalp responses. The width of the 95% confidence limits for the inverse prediction of the afferent volley from epidural and cervical responses was nearly a third narrower than that from scalp responses. At low stimulus intensities, scalp responses were consistently observed when spine responses were absent, and scalp responses had lower response thresholds than did spine responses. The latencies of the popliteal fossa responses were not well correlated with latencies of either the epidural or cervical responses. CONCLUSIONS: These correlation and inverse prediction data suggest that the size of an afferent volley may be predicted more accurately by spine responses than by scalp responses. The presence of scalp responses at intensities too low to elicit detectable spinal-level responses suggests that scalp responses may be considered a sensitive indicator of a minimal afferent volley.

Adolescent↗

Effect of recorded home blood pressure measurements on the staging of hypertensive patients.

OBJECTIVE: To compare clinic and home blood pressures for use in classifying patients in relation to a recent guideline for the diagnosis of hypertension. METHODS: Fifty patients were studied and classified on the basis of clinic pressures, using the Joint National Committee VI criteria, into the categories of normal, high-normal and stage 1, 2 or 3 hypertension. The patients were given instructions for using the Omron IC home-recording device to take their blood pressure daily for 1 week and then return the units for data recall and entry. Average home-recorded pressures were calculated and patients reclassified in terms of the Joint National Committee VI criteria if their home pressures were higher or lower than their clinic pressures. RESULTS: According to the clinic results, 18% of the participants had normal blood pressure, 16% had high-normal pressure, 48% were hypertensive stage 1, 16% were hypertensive stage 2 and 2% were hypertensive stage 3. Reclassification by recorded home pressures occurred in 54% of the participants: 40% downwards and 14% upwards. Only 46% remained in the same category for both clinic and recorded home pressures. CONCLUSION: Recorded home blood pressure measurement provides an accurate, reliable and unbiased assessment. Using the Joint National Committee VI classification system for both clinic and recorded home blood pressures, the data on the home pressures led, in this sample, to a downward classification three times more frequently than an upward one. We therefore conclude that recording home blood pressure is a highly useful method for assigning the appropriate blood pressure classification when using the Joint National Committee VI guidelines.

Aged↗

Impact of OSHA final rule--recording hearing loss: an analysis of an industrial audiometric dataset.

The 2003 Occupational Safety and Health Administration (OSHA) Occupational Injury and Illness Recording and Reporting Final Rule changed the definition of recordable work-related hearing loss. We performed a study of the Alcoa Inc. audiometric database to evaluate the impact of this new rule. The 2003 rule increased the rate of potentially recordable hearing loss events from 0.2% to 1.6% per year. A total of 68.6% of potentially recordable cases had American Academy of Audiology/American Medical Association (AAO/AMA) hearing impairment at the time of recordability. On average, recordable loss occurred after onset of impairment, whereas the non-age-corrected 10-dB standard threshold shift (STS) usually preceded impairment. The OSHA Final Rule will significantly increase recordable cases of occupational hearing loss. The new case definition is usually accompanied by AAO/AMA hearing impairment. Other, more sensitive metrics should therefore be used for early detection and prevention of hearing loss.

Adult↗

Transcutaneous electrocavernosography: a tool for recording the electromyographic activity of the corpora cavernosa.

PURPOSE: The electric activity of the corpora cavernosa (CC) is recorded by needle electrodes introduced into the CC. We investigated the hypothesis that transcutaneous electrocavernosography (ECG) would register electric waves similar to those recorded by the needle ECG but noninvasively. MATERIALS AND METHODS: The ECG was recorded transcutaneously in 35 healthy volunteers (mean age 37.6 +/- 4.8 SD years). Two silver-silver chloride electrodes were applied on the dorsum of the penis over 1 of the CC. A reference electrode was applied to the thigh. Intracavernosal ECG using 2 needle electrodes introduced into the CC was performed in the same subjects. At least two 20 minutes sessions were recorded for each subject. RESULTS: Slow waves (SWs) were registered transcutaneously. The waves from the 2 electrodes in each individual had the same frequency, amplitude and conduction velocity. They had a regular rhythm and were reproducible. The SWs were followed or superimposed by action potentials which occurred randomly. The transcutaneously recorded SWs were confirmed by the intracavernous route. Both routes had similar ECG recordings. CONCLUSIONS: The study demonstrated that the transcutaneous ECG recorded electric waves similar to those registered by the intracavernosal route. The transcutaneous ECG is simple, easy, non-invasive, and may be included as an investigative tool in the diagnosis of erectile dysfunction.

Action Potentials↗

Differences in oscillometric non-invasive blood pressure measurements recorded by different revisions of the Philips Component Monitoring System.

OBJECTIVE: To investigate whether a simulator can detect differences in oscillometric noninvasive blood pressure measurements in different revisions of the Philips Component Monitoring System. Philips revised the intraarterial-based algorithm with software revision C.0, and added an auscultation-based algorithm in revision C.1. METHODS: Three methods were adopted. Firstly, differences were assessed using the Dynatech Nevada CuffLink simulator. Five noninvasive blood pressure modules were tested on monitors with software revision C (software revision prior to C.0) and revision C.0. Monitor C.1 allows the selection of the original intraarterial algorithm (as for revision C), the improved intraarterial (revision C.0) or auscultation; two noninvasive blood pressure modules were tested on it.Secondly, pressures were recorded simultaneously from a participant's left and right arms by monitors C and C.0. The monitors were then swapped between arms and a second set of six pressures were recorded. The two sets were subtracted to calculate the differences between monitors, removing interarm differences. The experiment was carried out on two participants.Thirdly, pressures were recorded from three participants with a simultaneous reference auscultatory measurement. Six sets of simultaneous oscillometric and auscultatory determinations were recorded from monitors C and C.0. RESULTS AND CONCLUSIONS: All three methods revealed that the 'original' intraarterial-based algorithm in revision C recorded lower systolic, diastolic and mean arterial pressures than revision C.0, with the difference in diastolic pressure being the greatest. The difference in diastolic pressures between C and C.0 was up to 15 mmHg. The simulator evaluation finding of higher systolic and diastolic pressures recorded by the revised intraarterial algorithm (C.1 option 3) than by the auscultation-based algorithm (C.1 option 2) is in qualitative agreement with the regression equations of the clinical validation studies. The results suggest that simulators can identify the existence of differing algorithms used to measure blood pressure by the CMS monitor. Philips has continued to develop the algorithms used to determine the pressure by the oscillometric method. While significantly different pressures were recorded by the different revisions, it is interesting that each revision passed clinical validation studies.

Algorithms↗

Detection of cough signals in continuous audio recordings using hidden Markov models.

Cough is a common symptom of many respiratory diseases. The evaluation of its intensity and frequency of occurrence could provide valuable clinical information in the assessment of patients with chronic cough. In this paper we propose the use of hidden Markov models (HMMs) to automatically detect cough sounds from continuous ambulatory recordings. The recording system consists of a digital sound recorder and a microphone attached to the patient's chest. The recognition algorithm follows a keyword-spotting approach, with cough sounds representing the keywords. It was trained on 821 min selected from 10 ambulatory recordings, including 2473 manually labeled cough events, and tested on a database of nine recordings from separate patients with a total recording time of 3060 min and comprising 2155 cough events. The average detection rate was 82% at a false alarm rate of seven events/h, when considering only events above an energy threshold relative to each recording's average energy. These results suggest that HMMs can be applied to the detection of cough sounds from ambulatory patients. A postprocessing stage to perform a more detailed analysis on the detected events is under development, and could allow the rejection of some of the incorrectly detected events.

Algorithms↗