Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Motion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

Three-dimensional left ventricular wall motion in man. Coordinate systems for representing wall movement direction.

We have studied the three-dimensional (3D) motion of left ventricular (LV) epicardial points by tracking one to three dozen coronary artery bifurcations in eleven human subjects. Wall motion was analyzed using several different coordinate systems: (1) cylindrical centered about the LV long axis, (2) spherical with origin at the LV center-of-gravity (COG), and (3) spherical with origin at the LV center-of-contraction (COC), the best-fit 3D point toward which the wall moves. The coordinate systems were studied both fixed and moving with time. Three-dimensional motions were decomposed into three directional components, with high radial (in and out) percentages being regarded as the figure-of-merit of a given coordinate system. Average percentage radial motions were fixed cylindrical 16%, fixed spherical COG 35%, fixed spherical COC 47%, moving cylindrical 17%, moving spherical COG 30%, moving spherical COC 91%. Spherical systems were generally better than cylindrical systems, with the COC representing a better origin than the COG. Moving systems were appreciably better than fixed only for the COC model, indicating that the COC, which traverses up and down the LV midline, moves significantly while the other systems are more stationary. At each instant in time, almost all (91%) of the 3D motion of the entire heart wall is directed toward a single moving 3D point, the COC. Thus, there exists in principle a near-perfect 3D heart wall motion model. Approximately 25% of 3D wall motion is unseen in conventional monoplane views. Also, any model that represents 3D wall motion only along fixed straight 3D lines (eg, end-diastole to end-systole) necessarily ignores 27% of the true 3D heart wall motion.

Adult↗

Serial motion assessment by reference tracking (SMART): application to detection of local functional impact of chronic myocardial ischemia.

PURPOSE: To compare measurements of wall motion and thickening with and without correcting for cardiac twisting and shortening. METHOD: Inversion recovery Gd-DPTA perfusion and cine motion MRI were performed on 12 pigs with chronic ischemia induced by ameroid occluder. Analyses were based on conventional fixed plane imaging and serial motion assessment by reference tracking (SMART). RESULTS: Normal motion was 31.3 +/- 1.9%, and normal wall thickening was 41.4 +/- 2.2%. At the maximum perfusion defect, SMART wall motion was 10.5 +/- 2.4% and fixed wall motion was 20.6 +/- 1.7% (p < 0.004), SMART wall thickening was 20.1 +/- 4.4%, and fixed wall thickening was 32 +/- 1.9% (p < 0.03). CONCLUSION: SMART measurements of wall thickening and motion detect much smaller thickening and motion in ischemic myocardium than fixed radial metrics. SMART data, covering the entire heart, should prove twice as sensitive to abnormalities in motion and thickening, such as any produced by ischemic heart disease or improved by treatment.

Animals↗

Detection of residual wall motion after sustained myocardial infarction by gated 99Tcm-tetrofosmin SPECT: a comparison with echocardiography.

The differentiation of residual viability from necrotic myocardium in patients with a previously sustained myocardial infarction is important in deciding indications for revascularization. Myocardial viability can be assessed by studying perfusion and regional wall motion. With gated single photon emission computed tomography (SPECT), it is possible to augment SPECT perfusion data with ventricular functional data both at a global and regional level. The aim of the study was to analyse the concordance between wall motion score derived by gated SPECT and echocardiography. Furthermore, the agreement between myocardial perfusion and left ventricular wall motion was analysed with both techniques. We studied a homogenous group of 25 consecutive patients with a previous myocardial infarction (MI) using both gated SPECT 99Tcm-tetrofosmin myocardial perfusion imaging and two-dimensional echocardiography. Echocardiography was performed within 2 weeks of the gated SPECT study. Both for gated SPECT and for echocardiography the left ventricle was divided into seven regions per patient. For comparison, the gated SPECT regions were matched to the echocardiographic regions, resulting in a total of 175 regions. Prevalence of abnormal wall motion (akinetic or dyskinetic) was 23% (39/171) for echocardiography and 21% (36/175) for gated SPECT (P = NS). There was a high agreement in wall motion score between echocardiography and gated SPECT of 80% (136/171). The agreement between myocardial perfusion and myocardial wall motion was 82% (143/175) for gated SPECT and 76% (130/171) for echocardiography (P = NS). Nineteen (34%) of the 56 regions with severely diminished or absent myocardial perfusion showed normal or hypokinetic wall motion both by gated SPECT and echocardiography suggesting residual myocardial viability in malperfused regions. Our results suggest that, gated SPECT imaging is a reliable tool for the assessment of regional wall motion in post myocardial infarction patients. Furthermore, in patients with a previous myocardial infarction gated SPECT imaging has the potential to detect preserved wall motion in regions with fixed perfusion defects, which might be indicative of residual myocardial viability.

Adult↗

Changes in segmental intervertebral motion adjacent to cervical arthrodesis: a prospective study.

STUDY DESIGN: Prospective, observational. OBJECTIVES: Quantify the changes in intervertebral motion adjacent to cervical arthrodesis over time. SUMMARY OF BACKGROUND DATA: One of the frequently acknowledged sequelae following anterior cervical fusion is the development of adjacent segment disease. It has been argued that a spine fusion transfers stress to adjacent levels and results in increased compensatory motion. However, there are conflicting reports as to whether this actually occurs, and most of these are in vitro or retrospective clinical studies. METHODS: Patients undergoing anterior cervical discectomy and fusion underwent a preoperative dynamic fluoroscopic study, followed by imaging at regular intervals after surgery. Imaging data were analyzed by a validated software system. Relative motion between adjacent vertebrae was then calculated, and changes in motion cephalad to the fusion followed over time. RESULTS: Twenty-one patients were analyzed. Mean follow-up was 13 months (10-22 months). Intervertebral motion adjacent to the fusion changed by more than 4 degrees in 4 of the 21 patients. However, on average, there was no difference between preoperative and postoperative motion for shear, flexion-extension, or vertical displacement at the anterior or posterior disc space. CONCLUSIONS: Although there was some individual variation, at a mean of 13 months following surgery, there was no significant change in the average junctional intervertebral motion. If fusion is going to affect adjacent motion, it appears that this does not consistently occur in the first 1 to 2 years following surgery. Additionally, there was no observable relationship between motion and development of degenerative changes during this time.

Cervical Vertebrae↗

An analysis of chest wall and diaphragm motions in patients with idiopathic scoliosis using dynamic breathing MRI.

STUDY DESIGN: The motions of chest wall and diaphragm were measured in patients with scoliosis and healthy individuals using dynamic breathing magnetic resonance imaging. OBJECTIVES: To investigate the motions of the chest wall and the diaphragm during deep breathing in patients with idiopathic scoliosis. SUMMARY OF BACKGROUND DATA: Despite the central role of the respiratory motions in maintaining ventilation, it is difficult to measure and describe the motions because of the limited methods available. The kinematics of respiration in scoliosis have not yet been clarified. METHODS: Dynamic fast spoiled gradient-recalled echo sequences were used for 18 patients with idiopathic scoliosis and 9 healthy individuals. The chest wall and diaphragm motions were evaluated using a cineloop view and a fusion display of maximal inspiratory and expiratory images. The data were analyzed quantitatively by measuring displacements. RESULTS: Respiratory chest wall movements were significantly restricted in patients with scoliosis, although the diaphragm motion was normal. An analysis of the fusion magnetic resonance displays superimposed with the maximal inspiratory and expiratory images facilitated the understanding of the abnormal respiratory motion in patients with scoliosis. There was some correlation between the values of respiratory motions and pulmonary function tests. CONCLUSIONS: The present technique is useful for assessing respiratory mechanisms dynamically and noninvasively. One of the distinguishing features of respiratory dysfunction in patients with scoliosis is their limited chest wall motion.

Adolescent↗

Prospective motion correction of X-ray images for coronary interventions.

A method for prospective motion correction of X-ray imaging of the heart is presented. A 3D + t coronary model is reconstructed from a biplane coronary angiogram obtained during free breathing. The deformation field is parameterized by cardiac and respiratory phase, which enables the estimation of the state of the arteries at any phase of the cardiac-respiratory cycle. The motion of the three-dimensional (3-D) coronary model is projected onto the image planes and used to compute a dewarping function for motion correcting the images. The use of a 3-D coronary model facilitates motion correction of images acquired with the X-ray system at arbitrary orientations. The performance of the algorithm was measured by tracking the motion of selected left coronary landmarks using a template matching cross-correlation. In three patients, we motion corrected the same images used to construct their 3D + t coronary model. In this best case scenario, the algorithm reduced the motion of the landmarks by 84%-85%, from mean RMS displacements of 12.8-14.6 pixels to 2.1-2.2 pixels. Prospective motion correction was tested in five patients by building the coronary model from one dataset, and correcting a second dataset. The patient's cardiac and respiratory phase are monitored and used to calculate the appropriate correction parameters. The results showed a 48%-63% reduction in the motion of the landmarks, from a mean RMS displacement of 11.5-13.6 pixels to 4.4-7.1 pixels.

Algorithms↗

Use of three-dimensional Gaussian interpolation in the projector/backprojector pair of iterative reconstruction for compensation of known rigid-body motion in SPECT.

Due to the extended imaging times employed in single photon emission computed tomography (SPECT) and positron emission tomography (PET), patient motion during imaging is a common clinical occurrence. The fast and accurate correction of the three-dimensional (3-D) translational and rotational patient motion in iterative reconstruction is thus necessary to address this important cause of artifacts. We propose a method of incorporating 3-D Gaussian interpolation in the projector/backprojector pair to facilitate compensation for rigid-body motion in addition to attenuation and distance-dependent blurring. The method works as the interpolation step for moving the current emission voxel estimates and attenuation maps in the global coordinate system to the new patient location in the rotating coordinate system when calculating the expected projection. It also is employed for moving back the backprojection of the ratio of the measured projection to the expected projection and backprojection of the unit value (sensitivity factor) to the original location. MCAT simulations with known six-degree-of-freedom (6DOF) motion were employed to evaluate the accuracy of our method of motion compensation. We also tested the method with acquisitions of the data spectrum anthropomorphic phantom where motion during SPECT acquisition was measured using the Polaris IR motion tracking system. No motion artifacts were seen on the reconstructions with the motion compensation.

Algorithms↗

Linear vestibuloocular reflex during motion along axes between nasooccipital and interaural.

Linear vestibuloocular reflexes (LVORs) stabilize retinal images by producing eye movements to compensate for linear head motion. LVOR response characteristics depend upon gaze relative to the motion axis and binocular fixation distance. LVOR sensitivity during NO-axis motion increases as gaze eccentricity relative to the motion axis increases and as binocular fixation distance decreases. To fixate targets during forward head motion and rightward gaze, eyes must move to the right, but when looking left, the eyes must move to the left. In this study, LVORs were measured (binocular search coils) during 5.0 Hz horizontal motion along axes between and including NO and IA. This reorients head and otolith inputs relative to linear motion. We found that LVORs follow the same kinematics regardless of eye position in the head or head orientation relative to motion. Eye position information must be quickly and accurately integrated with otolith inputs to determine eye position (gaze) relative to linear head motion in space. The LVOR provides a behaviorally useful reflex for maintaining ocular fixation on visual targets during translation along any axis.

Animals↗

Effect of vision and stance width on human body motion when standing: implications for afferent control of lateral sway.

1. Measurements of human upright body movements in three dimensions have been made on thirty-five male subjects attempting to stand still with various stance widths and with eyes closed or open. Body motion was inferred from movements of eight markers fixed to specific sites on the body from the shoulders to the ankles. Motion of these markers was recorded together with motion of the point of application of the resultant of the ground reaction forces (centre of pressure). 2. The speed of the body (average from eight sites) was increased by closing the eyes or narrowing the stance width and there was an interaction between these two factors such that vision reduced body speed more effectively when the feet were closer together. Similar relationships were found for components of velocity both in the frontal and sagittal planes although stance width exerted a much greater influence on the lateral velocity component. 3. Fluctuations in position of the body were also increased by eye closure or narrowing of stance width. Again, the effect of stance width was more potent for lateral than for anteroposterior movements. In contrast to the velocity measurements, there was no interaction between vision and stance width. 4. There was a progressive increase in the amplitude of position and velocity fluctuations from markers placed higher on the body. The fluctuations in the position of the centre of pressure were similar in magnitude to those of the markers placed near the hip. The fluctuations in velocity of centre of pressure, however, were greater than of any site on the body. 5. Analysis of the amplitude of angular motion between adjacent straight line segments joining the markers suggests that the inverted pendulum model of body sway is incomplete. Motion about the ankle joint was dominant only for lateral movement in the frontal plane with narrow stance widths (< 8 cm). For all other conditions most angular motion occurred between the trunk and leg. 6. The large reduction in lateral body motion with increasing stance width was mainly due to a disproportionate reduction in the angular motion about the ankles and feet. A mathematical model of the skeletal structure has been constructed which offers some explanation for this specific reduction in joint motion.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: a volumetric dose measurement study.

Respiratory motion can introduce substantial dose errors during IMRT delivery. These errors are difficult to predict because of the nonsynchronous interplay between radiation beams and tissues. The present study investigates the impact of dose fractionation on respiratory motion induced dosimetric errors during IMRT delivery and their radiobiological implications by using measured 3D dose. We focused on IMRT delivery with dynamic multileaf collimation (DMLC-IMRT). IMRT plans using several beam arrangements were optimized for and delivered to a polystyrene phantom containing a simulated target and critical organs. The phantom was set in linear sinusoidal motion at a frequency of 15 cycles/min (0.25 Hz). The amplitude of the motion was +/- 0.75 cm in the longitudinal direction and +/- 0.25 cm in the lateral direction. Absolute doses were measured with a 0.125 cc ionization chamber while dose distributions were measured with transverse films spaced 6 mm apart. Measurements were performed for varying number of fractions with motion, with respiratory-gated motion, and without motion. A tumor control probability (TCP) model for an inhomogeneously irradiated tumor was used to calculate and compare TCPs for the measurements and the treatment plans. Equivalent uniform doses (EUD) were also computed. For individual fields, point measurements using an ionization chamber showed substantial dose deviations (-11.7% to 47.8%) for the moving phantom as compared to the stationary phantom. However, much smaller deviations (-1.7% to 3.5%) were observed for the composite dose of all fields. The dose distributions and DVHs of stationary and gated deliveries were in good agreement with those of treatment plans, while those of the nongated moving phantom showed substantial differences. Compared to the stationary phantom, the largest differences observed for the minimum and maximum target doses were -18.8% and +19.7%, respectively. Due to their random nature, these dose errors tended to average out over fractionated treatments. The results of five-fraction measurements showed significantly improved agreement between the moving and stationary phantom. The changes in TCP were less than 4.3% for a single fraction, and less than 2.3% for two or more fractions. Variation of average EUD per fraction was small (< 3.1 cGy for a fraction size of 200 cGy), even when the DVHs were noticeably different from that of the stationary tumor. In conclusion, IMRT treatment of sites affected by respiratory motion can introduce significant dose errors in individual field doses; however, these errors tend to cancel out between fields and average out over dose fractionation. 3D dose distributions, DVHs, TCPs, and EUDs for stationary and moving cases showed good agreement after two or more fractions, suggesting that tumors affected by respiration motion may be treated using IMRT without significant dosimetric and biological consequences.

Artifacts↗

Real-time motion detection of functional MRI data.

The objective of this work was to implement a motion-detection algorithm on a commercial real-time functional magnetic resonance imaging (fMRI) processing package for neurosurgical planning applications. A real-time motion detection module was implemented on a commercial real-time processing package. Simulated functional data sets with introduced translational, in-plane rotational, and through-plane rotational motion were created. The coefficient of variation (COV) of the center of intensity was used as a motion quantification metric. Coefficients of variation were calculated before and after image registration to determine the effectiveness of the motion correction; the limits of correctability were also determined. The motion-detection module allowed for real-time quantification of the motion in an fMRI experiment. Along with knowledge of the limits of correctability, this enables determination of whether an experiment needs to be reacquired while the patient is in the scanner. This study establishes the feasibility of using real-time motion detection for presurgical planning fMRI and establishes the limits of correctable motion.

Algorithms↗

The shoulder: adaptive motion correction of MR images.

PURPOSE: To evaluate an adaptive-motion-correction technique to reduce global motion in shoulder magnetic resonance (MR) images. MATERIALS AND METHODS: In the adaptive-motion-correction technique, interleaved navigator echoes are used to provide a measure of view-to-view displacement along the craniocaudal direction for each image echo in the acquisition. The information is then retrospectively applied to the k-space data to correct for global shoulder motion. This algorithm was evaluated in a series of 143 consecutive patient shoulder examinations by comparing the original image set for each patient with the same image set after retrospective correction by means of this algorithm. RESULTS: The average amplitude of craniocaudal motion was 1.4 mm. Image degradation due to motion was apparent in 100 (70%) of the 143 examinations. Application of the adaptive-motion-correction technique improved image quality in 73 (73%) of these 100 examinations or 51% of all 143 examinations. CONCLUSION: Adaptive motion correction improved image quality in approximately three-quarters of the examinations in which motion was present.

Humans↗

Mechanism of abnormal motion of the posterior leaflet in mitral stenosis.

Echocardiographic visualization of diastolic anterior motion of the posterior leaflet has proven to be diagnostic of mitral stenosis. In order to elucidate the mechanisms which underlie this finding and to explain why it is absent in some proven instances of mitral stenosis, we analyzed leaflet motion as a function of torque and derived a theoretic expression which permitted us to predict the direction of leaflet motion in mitral stenosis in terms of degree of commissural fusion and leaflet dimensions. The analysis was tested in an experimental model consisting of an isolated, perfused pig heart. Dimensions and degree of fusion of mitral valve leaflets were varied surgically in 5 specimens. Corresponding values proportional to torque were computed for each leaflet and the associated modifications of valve motion recorded cinematographically through a fiberscope inserted into the left ventricular cavity. The theoretical considerations indicated that, when leaflet commissures are fused, diastolic movement of the posterior leaflet is determined by the torques on both leaflets and that the relative length (base to free edge) of the leaflets is the major determinant of the direction of the resultant displacing force. The posterior leaflet may move posteriorly early in diastole until this motion is restricted by the fusion, but anterior motion of both leaflets results when the anteriorly directing force becomes dominant. Anterior motion of the posterior leaflet therefore occurs when leaflet fusion is extensive and the anterior leaflet remains longer than the posterior. Posterior motion of the posterior leaflet tends to occur with leaflet fusion, even in severe or moderate mitral stenosis, when the ratio of anterior to posterior leaflet length approximates unity. Direct observations of leaflet motion in the perfused porcine hearts confirmed these relationships.

Animals↗

Echocardiographic quantification of regional left ventricular wall motion with color kinesis.

BACKGROUND: Color kinesis is a new technology for the echocardiographic assessment of left ventricular wall motion based on acoustic quantification. This technique automatically detects endocardial motion in real time by using integrated backscatter data to identify pixel transitions from blood to tissue during systole on a frame-by-frame basis. In this study, we evaluated the feasibility and accuracy of quantitative segmental analysis of color kinesis images to provide objective evaluation of regional systolic endocardial motion. METHODS AND RESULTS: Two-dimensional echocardiograms were obtained in the short-axis and apical four-chamber views in 20 normal subjects and 40 patients with regional wall motion abnormalities. End-systolic color overlays superimposed on the gray scale images were obtained with color kinesis to color encode left ventricular endocardial motion throughout systole on a frame-by-frame basis. These color-encoded images were divided into segments by use of custom software. In each segment, pixels of different colors were counted and displayed as stacked histograms reflecting the magnitude and timing of regional endocardial excursion. In normal subjects, histograms were found to be highly consistent and reproducible. The patterns of contraction obtained in normal subjects were used as a reference for the objective automated interpretation of regional wall motion abnormalities, defined as deviations from this pattern. The variability in the echocardiographic interpretation of wall motion between two experienced readers was similar to the diagnostic variability between the consensus of the two readers and the automated interpretation. CONCLUSIONS: Color kinesis is a promising new tool that may be used clinically to improve the qualitative and quantitative evaluation of spatial and temporal aspects of global and regional wall motion. In this initial study, segmental analysis of color kinesis images provided accurate, automated, and quantitative diagnosis of regional wall motion abnormalities.

Adult↗

Tissue motion and elevational speckle decorrelation in freehand 3D ultrasound.

3D positioning is essential for quantitative volume analysis in 3D ultrasound. Particularly for freehand scanning without an external positioning device, such information must be estimated by analyzing the original 2D images prior to 3D reconstruction. Previous work on freehand 3D positioning has focused on elevational displacement estimation using speckle decorrelation for linear scans. However, the effects of other types of motion have been ignored. Given that all types of motion potentially introduce speckle decorrelation, the accuracy of the elevational displacement estimation is likely to be diminished by the presence of motions of other types. In the present study, simulations were performed to probe the effects of various motions on elevational displacement estimation. In particular, the effects of rotational motions on image correlation are investigated in detail. It is found that these motions significantly affect the estimation results and thus should be taken into account when reconstructing the 3D image. In addition, speckle variations also affect the estimation even when only elevational motion is present. Finally, full motion analysis in freehand scanning may not be possible by only using speckle correlation analysis unless speckle variations can be reduced and the correlation distribution under complex motion can be obtained.

Computer Simulation↗

A preliminary study on the measurement of static and dynamic motion at the glenohumeral joint.

Measurement of glenohumeral joint motion has, for the most part, been performed with the simple goniometer. The purpose of this paper is to describe a method for measuring and recording static and dynamic external rotation of the glenohumeral joint using the Cybex II Isokinetic Dynamometer and an MFE model 815 X-Y plotter. Static range of motion was assessed at 60 deg/sec using a slow arm action externally from a 90 degree abduction position. Dynamic motion was recorded at 300 deg/sec using a rapid rotational whipping action from a 90 degree abducted position. Measurements were recorded on three groups of athletes, and the influences of sex, hand dominance, overarm activity, and surgery were analyzed. The subjects in the first two groups were divided according to sex and their participation in overarm versus nonoverarm (control) activities. Static and dynamic motion in both groups was significantly influenced by sex and hand dominance (P less than 0.05). Although there was no overall difference in the motion measurements between the control and overarm groups, the interaction of this factor with sex and type of measurement was significant. Males who participated in overarm activities had, on the average, more static range of motion than males in the control group. A third group that had undergone a modified Bristow procedure for recurrent dislocation/subluxation of the shoulder demonstrated that static and dynamic range of motion were significantly reduced by the surgery (P less than 0.05). The average differences in static and dynamic motion between the surgical arm and its nonsurgical counterpart were 17.5 degrees and 21 degrees, respectively, resulting in an overall range of motion difference of 19 degrees.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope.

The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope.

Adolescent↗

Ultrasound quantitation of respiratory organ motion in the upper abdomen.

Organ motion can cause artefacts in abdominal imaging particularly with magnetic resonance imaging (MRI), and may often limit the diagnostic quality of an image. If spatial resolution and image quality are to improve in MRI and other imaging techniques, a more detailed understanding of organ motion is required. Despite the importance of organ motion little quantitative information is available to date. This study was the continuation of work instigated to investigate and quantify respiratory movements of upper abdominal organs for a group of healthy volunteers in order to provide the design criteria for a motion test object for use in MRI. A previous phase of the project allowed construction of a test object but refinements were needed to represent respiratory motion more closely as a consequence of the data presented in this paper. Improvements in the scanning technique and the recording procedure have revealed that, contrary to our initial findings, motion of the diaphragm and liver is predominantly in the superior-inferior (SI) direction with an average displacement (+/- SD) (quiet respiration) of 12 +/- 7 mm (range 7-28 mm) and 10 +/- 8 mm (range 5-17 mm), respectively. For some volunteers, motion of the kidneys can be complex, especially during deep inspiration. New data have been provided by this phase of the motion study on the displacement, velocity and acceleration of abdominal organs as a function of time. These data show that MRI motion artefact reduction techniques which assume that either organ displacement, velocity or acceleration are constant are only applicable during certain phases of the respiratory cycle.

Diaphragm↗