Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Internal Fixators”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

[Treatment of trans-symphyseal instability with an internal fixator. Outcome of a surgical technique on the basis of a case report].

Treatment of traumatic trans-symphyseal instability by internal plate fixation is the most common procedure. Besides the trauma-induced muscle damage, the implantation induces additional damage at the symphyseal origin of the m. rectus abdominis. The aim of this clinical case study was to examine whether it is possible to reduce the iatrogenic soft tissue damage while correcting trans-symphyseal instability using an internal fixator. After a transverse skin incision, two pedicle screws were drilled into the corpus ossis pubis next to the symphysis. Afterwards the crossbar was implanted and fixed. Generally, implantation of two self-trapping pedicle screws using a skin incision with a length of 6 cm is possible. Additional detachment of the m. rectus abdominis is not necessary. As a result of the mobility of the skin and subcutaneous tissue, the implantation of the crossbar beneath the m. rectus abdominis is possible. Stabilization of traumatic trans-symphyseal instability by internal fixation is a safe and easy method. Additional soft tissue damage can be prevented, but to achieve multidirectional stability some small modifications of the implant are necessary.

Bone Plates↗

Poor results following internal fixation of displaced subcapital femoral fractures: complacency in fracture reduction.

The results following internal fixation of displaced subcapital femoral fractures are poorer than for undisplaced fractures and are determined by both the quality of the initial reduction and the accuracy of implant placement. In a series of 26 consecutive displaced fractures internally fixed with Richards hip pins, satisfactory reduction was achieved in only 15 hips. Accurate reduction is a prerequisite for correct screw placement and occurred in only 4 of the 11 poorly aligned fractures, as opposed to 11 of the 15 well reduced ones. A total of 10 hips required a further surgical procedure as the result of complications. These results highlight the importance of accurate fracture reduction in facilitating implant placement as well as the importance of good surgical technique rather than reliance purely upon the implant. These already common fractures are assuming increasing socioeconomic importance as the elderly population grows, and successful management is vital for both the individual patient and future demands on the health service.

Adult↗

Calcium phosphate cement for augmentation did not improve results after internal fixation of displaced femoral neck fractures: a randomized study of 118 patients.

BACKGROUND: We wanted to evaluate whether augmentation with calcium phosphate cement can improve clinical and functional outcome following internal fixation of displaced femoral neck fractures. PATIENTS: 118 patients aged 60-98 years (95 women) were included. All patients were physically active and ambulatory before the fracture. Patients were randomized to treatment with closed reduction and fixation with two cannulated screws alone (controls: 60 patients) or screws combined with injection of calcium phosphate for augmentation around the screw threads and at the fracture site (augmented: 58 patients). All patients were allowed free weight bearing. Clinical and radiographic examinations were done by a physiotherapist directly after surgery, at 1 and 6 weeks, and at 6, 12 and 24 months. RESULTS: 24 patients, 14 augmented and 10 controls, died during the follow-up. There was 1 deep infection (augmented). Another 34 patients were reoperated with a total arthroplasty (20 in the augmented group and 14 controls) due to loss of reduction, nonunion or avascular necrosis (p = 0.1). There was no difference in pain or muscle strength between groups. Some activities of daily living (ADLs) were slightly better in the augmented patients during the first weeks, while there were no differences between groups later on. INTERPRETATION: Due to a trend towards more reoperations in the augmented group, and only a temporary clinical improvement during the early rehabilitation, augmentation as we used it cannot be recommended.

Activities of Daily Living↗

[Internal fixation for zygomatic arch fracture with super-high molecular weight poly D, L-lactic acid mini-plates and screws: a study in dogs].

OBJECTIVE: To investigate the internal fixation effects of super high molecular weight (Mv = 6.0 x 10(5) kD) poly D, L-lactic acid(PDLLA) mini-plates and screws. METHODS: 10 dogs were utilized in this experiment with the self-contrast study method, comparing with the titanium mini-plates and screws. RESULTS: The mechanical properties of the PDLLA mini-plates and screws appeared to be sufficient to enable undisturbed healing of depressed zygomatic arch fracture. CONCLUSION: The good fixation effect of PDLLA mini-plates and screws was as same as that of the titanium mini-plates and screws without the need of secondary operation.

Animals↗

Open reduction and internal fixation in 46 displaced intraarticular calcaneal fractures.

The subject of this report is the evaluation of 46 comminuted displaced intraarticular calcaneal fractures in 40 patients treated by open reduction and internal fixation. The results were validated by a score based on objective findings and a subjective gradation obtained by a visual analyzing score (VAS). The results were excellent or good in 30 treated fractures, while the results in 9 fractures were validated a satisfactory and in 7 as unsatisfactory. The results concerning disability and need for workman's compensation were promising in patients who had suffered fractures known to result in a high disability and compensation rate.

Adult↗

Open reduction and internal fixation of condylar fractures via an extended bicoronal approach with a masseteric myotomy.

Although condylar fractures of the mandible may be treated by closed reduction and appropriate physiotherapy, open reduction and internal fixation is indicated in specific circumstances. We report 25 cases of a previously unreported method of exposure of condylar fractures using an extended bicoronal approach combined with myotomy of the masseter muscle. Acceptable reduction and fixation was achieved in all cases with an early return to function. The incidence of complications was low, with three mild temporary facial palsies which had resolved by the sixth postoperative week and one haematoma beneath the bicoronal scalp flap. A cosmetically acceptable scar was produced in all cases. The excellent surgical exposure and protection of the facial nerve, combined with cosmetically acceptable scars, commend the use of this technique.

Adolescent↗

Rigid internal fixation of basilar fractures of the proximal phalanges by cancellous bone grafting only.

Ten patients with 13 basilar metaphyseal impaction fractures of the proximal phalanges of the fingers were treated with "rigid internal fixation" by bone grafting alone. When retrospectively reviewed at a mean follow-up of 32 months, bone healing had occurred without any relevant secondary displacement of the fracture fragments. The final ranges of motion were good and return to work was quicker than expected.

Adolescent↗

Open reduction and internal fixation of delayed union and nonunion of the distal humerus.

Nonunion of a condylar fracture of the distal humerus rarely occurs, but when present it is difficult to manage. We recommend internal fixation of the nonunion in combination with decortication and autogenous iliac crest bone grafting along with careful selection and placement of the implant. Postoperatively, the goal is preservation of elbow motion until the nonunion heals. We reviewed the cases of five patients who had surgery for nonunion of this fracture, all of which healed within 2-3 months after surgery. At final follow-up their average arc of motion was 88 degrees.

Adult↗

Bilateral proximal tibial stress fractures in osteoarthritic knee treated with simultaneous corrective osteotomy and internal fixation.

We report a patient who had bilateral stress fractures of proximal tibial shaft secondary to advanced osteoarthritis of knee with varus deformity. With treatment by simultaneous correction of deformity and internal fixation, the fractures healed uneventfully and the chronic knee pain was much alleviated. Due to progression of the symptom, right total knee replacement was finally performed 9 years later. Her left knee still did well after 13-year follow-up.

Aged↗

[Bouquet-type internal fixation of a series of 35 fractures of the upper end of the humerus].

The authors report on 35 fractures of the humerus neck treated by "bouquet" type internal fixation. The operative technique employed is that developed by Bombard and co-workers. A few variants of this technique are described. Only fractures that were badly dislocated were internally fixated. Slight dislocations were treated for the most part by simple orthopaedic measures. This technique may be used on patients of all ages and leads to early mobilization. It might be employed to advantage in the management of slightly dislocated fractures in respiratory failure or in patients with chest injuries.

Female↗

[Experiences with internal fixation of isolated fractures of the head of the radius].

The advantages of internal fixation of fractures, with the possibility of immediate resumption of the function of the fractured bone, are in contrast to the well-known complications described in the literature. These complications and our own unsatisfactory results after surgical treatment of fractures of the head of the radius induced us to carry out a randomized prospective study of primary functional treatment of such fractures without external or internal stabilization. From December 1991 through December 1992, a total of 70 patients were treated according to a strict treatment protocol at the Graz Hospital for Accident Surgery, and CT was used for observation of the healing process. The positive early results, which in 91% of all cases were classified as very good or good, the lack of complications that sometimes follow surgical treatment, the markedly earlier recovery of the patient's working capacity, and the clearly shorter--albeit somewhat more expensive--treatment period required have led us to continue using this method at our hospital and also to recommend its use elsewhere.

Adult↗

Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring.

This study tested different methods of internal fixation of a symphyseal disruption, in comparison with the mechanics of the intact pelvis. Unembalmed cadaveric pelves were tested in simulated bilateral stance in a servohydraulic materials-testing machine. Motion of the superior and inferior pubic symphysis, and at two levels of the posterior sacroiliac complex, was measured using high resolution displacement transducers. The fixations tested were (1) double plating (4.5 mm reconstruction plates), (2) wire loops around two 6.5 mm, fully threaded cancellous screws, and (3) an absorbable suture material (polydioxanone). Each pelvis was first tested intact, recording displacements in response to a cyclic axial load up to a maximum of 500 N applied through the proximal sacrum. The pubic symphysis was then sectioned and the sacrum fractured to produce an unstable pelvis (Tile C-type). Recordings were then repeated, following fixation of the sacral fracture with lag screws and sequential fixation of the symphysis with each of the test methods. The results from eight pelves revealed that internally fixed symphyseal motion was generally greater than intact, regardless of fixation method. The superior symphysis was usually compressed, while there was distraction inferiorly. Wiring resulted in significantly less symphyseal motion than the other methods (P < 0.02), provided four loops were used, reducing the separation inferiorly. There was no significant difference in sacral fracture motion between the three methods. The results indicate that in osteoporotic bone, as used in this study, symphyseal wiring is best able to oppose the tensile loads in the inferior symphysis that are associated with bilateral stance loading. These biomechanical findings must be interpreted within the broader context of surgical management of these complex injuries.

Aged↗

Postoperative wound complications after internal fixation of closed calcaneal fractures: a retrospective analysis of 126 consecutive patients with 148 fractures.

AIM: The aim of the study was to analyse the number of soft-tissue complications after internal fixation of calcaneal fractures and to evaluate risk factors leading to these complications. MATERIAL: A retrospective analysis of 126 consecutive patients with 148 operatively treated calcaneal fractures was performed. Only primarily closed fractures were included in the study. RESULTS: Wound healing was problematic in 35 cases (24 per cent). The wound was infected in 23 cases (16 per cent) and a wound edge necrosis was observed in 12 cases (8 per cent). The soft tissue complication needed operative treatment in 20 cases (14 per cent). The complications did not lead to amputations in any case. In the end of the follow up all wounds had healed. CONCLUSIONS: The statistical analysis identified a longer delay in surgery and longer operation time to be positive risk factors for wound complications.

Adolescent↗

Internal fixation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study.

We performed ninety-six internal-fixation procedures for fracture or non-union of the humeral shaft in eighty-four patients, with a mean follow-up of 32.6 months (range, three months to fourteen years). The primary indications for operative intervention included humeral shaft fracture in a patient with multiple trauma, non-union, inadequate reduction of a humeral shaft fracture by closed methods, pathological humeral-shaft fracture, and progressive radial-nerve palsy. Methods of internal fixation included compression plates and screws and intramedullary Küntscher nails or Rush rods. The use of an AO/ASIF compression plate or interfragmentary lag screws with an AO/ASIF neutralization plate in twenty-seven multiply-injured patients resulted in a union rate of 100 per cent and generally good motion of the shoulder and elbow. Five multiply-injured patients also obtained good results through fixation by a modified Hackethal technique using two Rush rods. The use of intramedullary Küntscher nails resulted in a rate of union of 91 per cent in eleven multiply injured patients. Ten patients with non-union of a humeral shaft fracture had an 80 per cent rate of union with the use of an AO/ASIF compression plate. The use of a Küntscher nail in eleven patients with non-union resulted in a rate of union of only 73 per cent and frequently caused subacromial impingement. Fractures of the humeral shaft that had had an inadequate reduction by closed means or were associated with progressive radial-nerve palsy were best managed by a compression plate or the modified Hackethal technique.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Titanium wire internal fixation for stabilization of injury of the cervical spine: clinical results and postoperative magnetic resonance imaging of the spinal cord.

Nine patients with dislocation of the cervical spinal with posterior ligamentous damage were treated with posterior internal fixation using a twisted pair of 22-gauge titanium wires and iliac crest bone fusion. Fixation using the titanium wire was compared with fixation using stainless steel wire for differences in surgical insertion, long term stability of bony fusion, and postoperative magnetic resonance imaging (MRI) artifacts near the implanted wire. MRI of the cervical spine is valuable for diagnosing the acute and chronic consequences of traumatic cervical spinal injury by providing anatomic evaluation of both the spinal cord and the supporting bony/ligamentous structures in the neck. Because MRI is an accurate and sensitive noninvasive test, it is especially useful for the long-term serial assessment of the region near the cervical dislocation site to detect the sequelae of spinal cord injury, including syrinx, arachnoid cyst, cord tethering, and persistent mechanical impingement on the spinal cord or spinal roots. Previous attempts at our institution to obtain useful MRI scans of the cervical region adjacent to stainless steel wires after posterior wire fixation have failed due to marked imaging artifacts from the ferromagnetic properties of these wires. Our substitution of biocompatible titanium wire (Titanium 6 A1-4V ELI alloy, Specialty Steel and Forge, Leonia, New Jersey) for stainless steel wire produced identical immediate stabilization and ultimate bony fusion of the fracture and yielded minimal MRI artifacts overlying the immediately adjacent spinal cord and neural canal; however, the installation was technically more difficult, because of the titanium wire's greater stiffness.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Rigid internal fixation of mandibular fractures--an analysis of 45 patients treated according to the ASIF method.

A report is given of 45 patients with fractures of the mandible treated by the method of rigid internal fixation. In a majority of cases, there were either absolute or relative contraindications for an IMF. Most of the fractures plated were body fractures of the mandible, followed by angular, and symphysis fractures. In 4 cases, the fractures, caused by gunshots, were compound ones. In these, extensive soft tissue reconstructions were also performed. In a majority of the patients, good primary healing was observed, and the mean hospitalization time was only 4.4 days. The infection rate of 13% was, however, relatively high, and a few disturbances were seen with respect to motor and sensory function of the lower lip. Slight occlusal dysharmonies were registered in 23%, on an average of 22 weeks postoperatively, but these could be adjusted with a minimum of grinding. It was concluded that bone plating is a useful method in the treatment of several different types of mandibular fractures including the severe compound ones. The method can be especially recommended in cases in which an IMF is contraindicated or should be avoided. The possibilities for decreasing the frequency of postoperative infections are discussed.

Adolescent↗

Fractures of the second cervical vertebra: Internal fixation by interlaminar wiring.

Fractures of the 2nd cervical vertebra are frequently undetected on initial evaluation. Tomography may be necessary to delineate the fracture. This is a report of 20 patients treated by internal fixation using interlaminar wiring. There was no operative mortality. Follow-up studies, an average of 25 months after operation, demonstrated satisfactory results and no evidence of delayed neurological deficit.

Adolescent↗

[Internal fixation (with functional stability) of impression fractures of the tibial condyle with a modified plate. I (author's transl)].

A modified plate was constructed, providing a safer and simple way of functionally stable internal fixation in the impression fractures of the tibial condyle. After a brief survey on the previous methods, the purpose of the present modification is described, with the demonstration of the advantages and the technique in several cases. Experiences and results of 9 years with this method will be published in an other article.

Bone Plates↗