Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

Speciation determination of arsenic in urine by high-performance liquid chromatography-hydride generation atomic absorption spectrometry with on-line ultraviolet photooxidation.

A coupled system for arsenic speciation determination based on high-performance liquid chromatography (HPLC), on-line UV photooxidation and continuous-flow hydride generation atomic absorption spectrometry (HGAAS) was built from commercially available modules with minor modifications to the electronic interface, the software and the gas-liquid separator. The best results were obtained with strong anion-exchange columns, Hamilton PRP X-100 and Supelcosil SAX 1, and gradient elution with phosphate buffers containing KH2PO4-K2HPO4. The on-line UV photooxidation with alkaline peroxodisulfate, 4% m/v K2S2O8-1 mol l-1 NaOH, in a PTFE knotted reactor for 93 s ensures the transformation of inorganic AsIII, monomethylarsonate, dimethylarsinate, arsenobetaine, arsenocholine, trimethylarsine oxide and tetramethylarsonium ion to arsenate. About 32-36 HPLC-UV-HGAAS runs could be performed within 8 h, with limits of detection between 2 and 6 micrograms l-1 As, depending on the species. The method was applied to the analysis of spot urine samples and certified urine reference materials (CRMs). Upon storage at 4 degrees C, reconstituted CRMs are stable for at least 2 weeks with respect to both their total arsenic content and the individual species distribution.

Arsenic↗

A continuous-flow system for high-precision kinetics using small volumes.

A generally applicable continuous-flow kinetic analysis system that gives data of a precision high enough to measure small kinetic isotope effects for enzymatic and nonenzymatic reactions is described. It employs commercially available components that are readily assembled into an apparatus that is easy to use. It operates under laminar flow conditions, which requires that the time between the initiation of the reaction in the mixer and the observation be long enough that molecular diffusion can effect a symmetrization of the concentration profile that results from a thin plug of reagents introduced at the mixer. The analysis of a second-order irreversible reaction under pseudo-first-order conditions is presented. The Yersinia pestis protein tyrosine phosphatase catalyzed hydrolysis of p-nitrophenyl phosphate is characterized with the system, and a proton inventory on kcat is presented.

Diffusion↗

Identification of pesticides by liquid chromatography--particle beam mass spectrometry using electron ionization and chemical ionization.

Liquid chromatography-mass spectrometry (LC-MS) with a particle beam (PB) interface is used to separate and identify a group of pesticides. The mass spectra obtained under the different ionization modes, electron ionization (EI) and positive and negative chemical ionization (PCI and NCI) are compared. The operating conditions under each mode, determined by studying the influence on the ion abundance of the ion source temperature of the EI mode, and the gas pressure and ion source temperature in the methane CI were optimized. EI was more sensitive than PCI and NCI and of the latter two modes, NCI gave higher responses, especially for organophosphorus compounds. When on-line solid-phase extraction-LC-PB-MS was applied to real samples, limits of detection in full scan mode were in the range of 0.5 and 10 micrograms l-1 for EI. The analysis of real samples by on-line solid-phase extraction-LC-PB-MS enabled EI detection of one of the pesticides studied and confirmation by PCI and NCI. The combined EI/CI information also enabled the detection of some non-target compounds.

Chromatography, Liquid↗

Study of quantitative analysis of traces in low-conductivity samples using capillary electrophoresis with electrokinetic injection.

In this work we tried to clarify the relation between the signal detected by indirect UV mode and the concentration of the analyte introduced by electrokinetic (EK) injection from samples having small but different conductivities. A simple external calibration procedure was proposed for quantitative determination of traces that are present in low-conductivity samples. It was found that measuring the current through the capillary filled with the samples provides useful correction factor for the external calibration.

Calibration↗

Sequential injection analysis for the simultaneous determination of clavulanic acid and amoxicillin in pharmaceuticals using second-order calibration.

In this paper, we report on a method for quantifying clavulanic acid and amoxicillin simultaneously in pharmaceuticals using sequential injection analysis (SIA) with a diode-array spectrophotometric detector and multivariate curve resolution with alternating least squares (MCR-ALS). We optimized the experimental parameters so that the analytical sequence could distinguish the concentrations and spectrum profiles of the species of interest with optimum resolution quality. After establishing the optimum conditions, we quantified clavulanic acid and amoxicillin in four pharmaceuticals. In most cases our results were slightly higher than those in the prospectus of the pharmaceutical. The relative standard deviations were below 5% for amoxicillin and below 7% for clavulanic acid. These results are acceptable because, to prevent degradation due to bacteriostatic activity, the concentration of the main reactant is usually higher.

Amoxicillin↗

Stability indicating reversed-phase ion-pairing liquid chromatographic determination of vertilmicin sulfate as bulk drug and in injections.

A simple reversed-phase high performance liquid chromatographic method was developed for the analysis of vertilmicin sulfate, a novel aminoglycoside (AG). UV detection was used to determine vertilmicin sulfate and its related compounds in drug substance and products without sample derivatization. The method was used to determine the content of vertilmicin and its related compounds and test the stability of vertilmicin sulfate as drug substance and in injections, which was required for registration of new drug.

Aminoglycosides↗

Quantitative determination of trace concentrations of tetracycline and sulfonamide antibiotics in surface water using solid-phase extraction and liquid chromatography/ion trap tandem mass spectrometry.

The occurrence of human and veterinary pharmaceutical compounds in surface waters (e.g. streams, lakes and reservoirs) is an important emerging environmental issue. There is a need for robust, sensitive and reliable analytical methods for measuring these compounds in a variety of natural water and wastewater matrices. This paper describes a method for the determination of seven tetracycline (TC) and six sulfonamide (SA) compounds in pristine and wastewater-influenced surface water using solid-phase extraction, and LCQ Duo ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) with positive electrospray ionization (ESI(+)) and selected reaction monitoring (SRM). The seven TCs and six SAs analyzed using this method include oxytetracycline (OTC), chlortetracycline (CTC), tetracycline (TC), democlocycline (DMC), doxycycline (DXC), meclocycline (MCC), minocycline (MNC), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethazine (SMT), sulfachloropyridazine (SCP), sulfamethoxazole (SMX), and sulfadimethoxane (SDM). This study discusses the effects of flow rate, LC column diameter and LC column temperature on UV and/or mass peak quality of the different analytes. Several product ions for MS/MS detection have been identified and compared for ion trap and triple quadrupole LC/MS/MS instruments. Statistical analysis for determination of the method detection limit (MDL), accuracy and precision of the method is described. Matrix effects are evaluated in deionized, pristine and wastewater-influenced river water. The method is applied to evaluate the occurrence of these compounds in a small watershed in northern Colorado.

Anti-Bacterial Agents↗

An improved analytical method for the determination of urea nitrogen isotopomers in biological samples utilizing continuous flow isotope ratio mass spectrometry.

Over the past few years numerous dual inlet isotope ratio mass spectrometry (IRMS) applications have been adapted to continuous flow systems which allow the automation of sample admission and a higher throughput. The isotopomer analysis of urea nitrogen by IRMS requires the offline conversion of urea into nitrogen gas before analysis. The oxidation of urea with LiOBr results in the monomolecular degradation of urea, which preserves the identity of the parent urea molecule, and has to be conducted under vacuum to prevent contamination with atmospheric nitrogen. We have developed an offline system of urea degradation utilizing disposable Exetainers, in which atmospheric nitrogen is displaced by helium. Recovery of urea nitrogen was linear within the range of the standards tested (0 to 420 microg nitrogen) and standard curves for 15N15N-urea standards showed high coefficients of determination (R2 > 0.9998). A small portion of urea degrades in a non-monomolecular fashion and has been shown to depend on the concentration of urea in the sample. Long-term storage of prepared samples showed a decline in 15N15N enrichment, suggesting air contamination. However, samples were stable for 24 h, which allows for the analysis of large sample batches. Interest in urea metabolism, particularly in ruminant species, has increased recently due to the environmental implications of urea and nitrogen excretion by farm animals. This novel analytical method will allow for accurate measurements and the rapid throughput needed in order to support these field studies.

Animals↗

Evaluation of two-beam fluorescence cross correlation spectroscopy for electrophoretic analysis of protein digests.

In this report, we evaluate experimentally and through the use of simulations and calculations the possibility of using 2-beam fluorescence cross correlation spectroscopy (2BFCCS) for the multicomponent electrophoretic analysis of peptides. The concept described has potential as a high throughput, extraordinarily sensitive means of identifying proteins and accelerating proteome studies. We present Monte Carlo simulation methods and results using them that help in understanding the capabilities and limitations of 2BFCCS for protein identification. We have calculated the expected pH dependent mobility and resultant 2BFCCS fingerprint spectra for a randomly selected subset of the peptides present upon digestion of horse myoglobin by trypsin. We demonstrate experimentally the multicomponent analysis of a mixture containing a fluorescently labeled peptide and a free fluorophore. We also demonstrate experimentally the ability to measure migration rates of dilute, single-fluorophore species over more than 2 orders of magnitude in linear velocity (between 4.2 mm s(-1) and 640 mm s(-1)).

Animals↗

Dual injection capillary electrophoresis: foundations and applications.

The state of the art of capillary electrophoresis (CE) approaches based on dual injection is here reported. Dual injection strategies have been proposed with three main objectives: (i) to provide information about reaction kinetics and/or related parameters, (ii) to perform in-capillary derivatization for improving separation and/or determination, (iii) to develop electrophoretic methods for the simultaneous analysis of anionic and cationic compounds. For the first two purposes, dual injection, which involves sample and reagent, can be realized either from the same end of the capillary (electrophoretically mediated microanalysis, EMMA) or from the two ends of the capillary (electroinjection analysis, EIA). The third objective, with dual injection of sample from the two ends of the capillary, takes advantage of moving cationic and anionic compounds with opposite directions. The foundations of each alternative, conditions necessary for working with them, restrictions, applications as well as perspectives are reviewed in order to establish the advantages, shortcomings, and convenience or no of their use in comparison to conventional CE.

Electrophoresis, Capillary↗

Automated determination of total polyphenols in apple juice.

An automated method of total polyphenols analysis in apple juice using the Folin-Ciocalteu reagent is presented. Chlorogenic acid was selected as the standard since a similar kinetic behaviour, standard-sample, was observed. A straightforward method with good reproducibility (CV < 1%), sampling frequency (48 h-1) and correlation with the traditional batch method (r = 0.9924) is proposed.

Beverages↗

Metabolic transition step from ethanol consumption to sugar/ethanol consumption by Saccharomyces cerevisiae.

The metabolic pathway shift between only ethanol consumption to both sugar/ethanol consumption was measured by on-line analysis of respiratory quotient of a Saccharomyces cerevisiae. The experiments were carried out in a fed-batch culture under aerobic conditions. During the transition phase, respiratory quotient (RQ) profile shows that sugar can be metabolized through the fermentative pathway even to values of RQ lower than 1.

Algorithms↗

Rapid and convenient determination of oxalic acid employing a novel oxalate biosensor based on oxalate oxidase and SIRE technology.

A new method for rapid determination of oxalic acid was developed using oxalate oxidase and a biosensor based on SIRE (sensors based on injection of the recognition element) technology. The method was selective, simple, fast, and cheap compared with other present detection systems for oxalate. The total analysis time for each assay was 2-9 min. A linear range was observed between 0 and 5 mM when the reaction conditions were 30 degrees C and 60 s. The linear range and upper limit for concentration determination could be increased to 25 mM by shortening the reaction time. The lower limit of detection in standard solutions, 20 microM, could be achieved by means of modification of the reaction conditions, namely increasing the temperature and the reaction time. The biosensor method was compared with a conventional commercially available colorimetric method with respect to the determination of oxalic acid in urine samples. The urine oxalic acid concentrations determined with the biosensor method correlated well (R=0.952) with the colorimetric method.

Biosensing Techniques↗

On-line hyphenation of flow injection, miniaturized capillary electrophoresis and atomic fluorescence spectrometry for high-throughput speciation analysis.

A hyphenated technique was developed for high-throughput speciation analysis by on-line coupling of flow injection (FI), miniaturized capillary electrophoresis (CE) and atomic fluorescence spectrometry (AFS). Two interfaces were used to couple all three systems: the first to couple FI and CE and the second to couple miniaturized CE and AFS. The first interface was a modified flow through chamber, connected to the FI valve with a piece of PTFE tube (0.1mm i.d.x 20 cm long). The capillary outlet was coupled to the AFS by using the second concentric "tube-in-tube" interface. Split sampling was achieved in the electrokinetic mode. Inorganic mercury (Hg(II)) and methylmercury (MeHg(I)) were taken as model analytes to demonstrate the performance of the developed hyphenated technique. A volatile species generation (VSG) technique was employed to convert the analytes from the CE effluent into their respective volatile species. Baseline separation of Hg(II) and MeHg(I) was achieved by CE in a 50 microm i.d.x 8 cm long capillary at 3.0 kV within 60s. The precisions (RSD, n=12) were in the range of 0.7-0.9% for migration time, 3.8-4.2% for peak area, and 2.1-3.5% for peak height. The detection limits were 0.1 and 0.2 microgmL(-1) (as Hg) for Hg(II) and MeHg(I) with a sample throughput of 60 samples h(-1). The recoveries of both mercury species in the water samples studied were in the range of 93-106%.

Electrophoresis, Capillary↗

Real-time monitoring of lactate extrusion and glucose consumption of cultured cells using a lab-on-valve system.

Microsequential injection (microST) provides microfluidic operations that are ideally suited for cellular function studies and as a means of validating targets for drug discovery. MicroSI carried out within the lab-on-valve (LOV) manifold, is an ideal platform for spectroscopic studies on living cells that are grown on microcarrier beads and kept thermostated while their metabolism is probed in real-time. In this paper a microbioreactor is integrated into the LOV manifold allowing measurement of cellular lactate extrusion and glucose consumption rates of a cell culture that is automatically renewed prior to each measurement. Glucose consumption and lactate extrusion are monitored using NAD-linked enzymatic assays. The microSI-LOV setup has demonstrated a linear analysis range of 0.05-1.00 mM for lactate and 0.1-5.6 mM for glucose. These assays were conducted in a serial fashion requiring 3 microL of cellular perfusate and 10 s for glucose determination and 30 s for the lactate assay. Overall waste generated per lactate/glucose assay is < 200 microL. This work was performed using two different transfected hepatocyte cell lines, which adhere to Cytopore microcarrier beads. This novel approach to metabolic screening allows for the rapid evaluation of the effects of dosing cells with chemical agents.

Animals↗

[Study on the determination of trace gallium in molybdenum-coated pyrolytic graphite tube by electrothermal absorption spectrometry].

The effects on gallium atomization in the pyrolytic graphite tube imposed by different matrix modifiers and different coatings were discussed detailedly in this paper. In the presence of matrix modifier of Ni(NO3)2 the matrix interference was eliminated efficiently. The pyrolytic graphite tubes were coated differently with lanthanum, zirconium, and molybdenum to avoid producing gallium carbide. Results showed that the tube with molybdenum coating was the best. On this basis, the mechanism of gallium atomization in the molybdenum-coated pyrolytic graphite tube using Ni(NO3)2 as a matrix modifier was studied furthermore; in addition, the parameters of the operation were optimized. As a result, a new method improved in many aspects was developed to detect trace gallium in complicated sample of gangue. The outcomes of practical applications indicated that the method could satisfy the requests of analysis and that the manipulations were simple to achieve. The characteristic content, the detection limit, and the adding recoveries were 2.12 x 10(-11) g, 1.4 x 10(-10) g and 97.4%-102.7% respectively, and the relative standard deviation was less than or equal to 3.6% (n = 11).

Absorption↗

Spectral and kinetic studies on the activation of soluble guanylate cyclase by nitric oxide.

The soluble form of guanylate cyclase (sGC) is the only definitive receptor for the signaling agent nitric oxide (.NO). The enzyme is a heterodimer of homologous subunits in which each subunit binds 1 equiv of 5-coordinate high-spin heme. .NO increases the Vmax of sGC up to 400-fold and has previously been shown to bind to the heme to form a 5-coordinate complex. Using stopped-flow spectrophotometry, it is demonstrated that the binding of .NO to the heme of sGC is a complex process. .NO first binds to the heme to form a 6-coordinate nitrosyl complex, which then converts to a 5-coordinate nitrosyl complex through one of two ways. For 28 +/- 4% of the heme, the 6-coordinate nitrosyl complex rapidly (approximately 20 s-1) converts to the 5-coordinate complex. For the remaining 72 +/- 4% of the heme, the conversion of the 6-coordinate nitrosyl complex to a 5-coordinate nitrosyl complex is slow (0.1-1.0 s-1) and is dependent upon the interaction of .NO with an unidentified non-heme site on the protein. The heme (200 nM) was completely converted to the 5-coordinate state with as little as 500 nM .NO, and the equilibrium dissociation constant of .NO for activating the enzyme was determined to be < or = 250 nM. Gel-filtration analysis indicates that the binding of .NO to the heme has no effect on the native molecular mass of the protein. Correlation of electronic absorption spectra with activity measurements indicates that the 5-coordinate nitrosyl form of the enzyme is activated relative to the resting 5-coordinate ferrous form of the enzyme.

Animals↗

Simultaneous determination of L- and D-carnitine using a sequential injection analysis/amperometric biosensors system.

A sequential injection analysis (SIA) system is described for the simultaneous determination of L-and D-carnitine using amperometric biosensors as detectors. The SIA system was used, because of its high precision, accuracy and low sample and buffer consumption. The biosensors were designed using physical and chemical immobilization of L-amino acid oxidase and horseradish peroxidase (HRP) for the assay of L- carnitine, and D-amino acid oxidase and HRP for the assay of D-carnitine. The linear concentration ranges are in the pmol/l to nmol/l magnitude order, with very low limits of detection. The biosensors/SIA system was used reliably for on-line process control of the enantiopurity of carnitine with a frequency of 34 samples per hour.

Biosensing Techniques↗