Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Endoscopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

Total radiated power, infrared output, and heat generation by cold light sources at the distal end of endoscopes and fiber optic bundle of light cables.

BACKGROUND: Skin burns and ignition of drapes have been reported with the use of cold light sources. The aim of the study was to document the temperature generated by cold light sources and to correlate this with the total radiated power and infrared output. METHODS: The temperature, total radiated power, and infrared output were measured as a function of time at the end of the endoscope (which is inserted into the operative field) and the end of the fiber optic bundle of the light cable (which connects the cable to the light port of the endoscope) using halogen and xenon light sources. RESULTS: The highest temperature recorded at the end of the endoscope was 95 degrees C. The temperature measured at the optical fiber location of the endoscope was higher than at its lens surface (p < 0.0001). At the end of the fiber optic bundle of light cables, the temperature reached 225 degrees C within 15 s. The temperature recorded at the optical fiber location of all endoscopes and light cables studied rose significantly over a period of 10 min to reach its maximum (p <0.0001) and then leveled off for the duration of the study (30 min). The infrared output accounted only for 10% of the total radiated power. CONCLUSIONS: High temperatures are reached by 10 min at the end of fiber optic bundle of light cables and endoscopes with both halogen and xenon light sources. This heat generation is largely due to the radiated power in the visible light spectrum.

Cold Temperature↗

Duodenal gangliocytic paraganglioma treated with endoscopic hemostasis and resection.

Gangliocytic paragangliomas are exceedingly rare tumors that arise in close proximity to the papilla of Vater. There are few reports of the endoscopic resection of duodenal gangliocytic paraganglioma. A 61-year-old woman was admitted with a complaint of melena. Endoscopic examination revealed a pedunculated submucosal tumor with erosion in the third portion of the duodenum. Hemostasis, using a gold probe, was performed. Nine days later, we successfully resected the tumor, using endoscopic polypectomy. To determine the depth of tumor invasion, endoscopic ultrasonography was used. The size of the tumor was 3.0 x 2.5 x 1.0 cm. A total of 25 cases of duodenal gangliocytic paraganglioma have been reported in Japan. Generally, this tumor is considered benign. However, resection was performed in many patients because preoperative diagnosis was impossible. In Japan, no previous studies have reported using endoscopic hemostasis, to our knowledge. Our patient is the fourth in Japan to be treated by endoscopic resection. We report on our patient, with a review of the literature.

Duodenal Neoplasms↗

Endoscopic hemostasis using fibrin adhesive to treat hemorrhage in the upper digestive system.

PURPOSE: There are several methods of achieving endoscopic hemostasis of hemorrhage in the upper digestive system. We compared the therapeutic results and advantages of using a local injection of fibrin adhesive for endoscopic hemostasis, which we have found more effective than other hemostatic methods. METHODS: Between October 2000 and April 2002, 16 patients with hemorrhage in the upper digestive system underwent endoscopic hemostasis using fibrin adhesive. The hemorrhage was caused by a hemorrhagic tendency from liver disease, anticoagulant therapy, or failed hemostasis with clipping or local ethanol injection. The fibrin adhesive was injected through a standard 21-gauge endoscopic needle using the so-called sandwich method. RESULTS: Hemostasis was successfully achieved by a single local injection of fibrin adhesive, in all except one patient who had been on anticoagulant therapy for a long time and needed an additional local injection of fibrin adhesive. CONCLUSION: Fibrin adhesive does not cause any tissue injury, and a sufficient amount can be injected endoscopically even in patients with liver dysfunction and those on anticoagulant therapy. Thus, we think that endoscopic hemostasis with fibrin adhesive is safe and effective.

Aged↗

[Endoscopically-assisted LeFort I osteotomy in distraction procedures of the maxilla].

PURPOSE: The purpose of this study was to demonstrate the feasibility of combining a minimally invasive endoscopic approach to the maxilla with transverse and sagittal distraction procedures. MATERIALS AND METHODS: Four human cadavers were used for training of a minimally invasive access to the maxilla to perform an endoscopically assisted Le Fort I osteotomy, before this technique was applied in three patients with transverse and sagittal growth deficits of the maxilla. Access to the maxilla was gained through a small mucosa incision in the vestibule to create a visualization port to the maxillary sinus through a bur hole. Landmarks were identified through the endoscope before a Le Fort I osteotomy was performed using straight and angulated chisels of different form and angulation. In two patients, the maxilla was split sagittally to perform a transverse maxillary expansion. In one patient, a buried distractor was applied close to the piriform aperture to correct a sagittal growth deficit in a hypoplastic maxilla. RESULTS: The endoscopic exposure of the maxillary sinus walls from within the sinus, the accurate identification of landmarks, and the creation of a Le Fort I osteotomy was achieved in all cases. Distractor application close to the piriform aperture rendered good stability. CONCLUSION: The results of these case reports indicate that the endoscopic approach to the maxillary sinus allows excellent exposure of the sinus walls to perform an endoscopically assisted Le Fort I osteotomy. The combination of endoscopy and osteodistraction supports the trend toward minimally invasive, less traumatic surgical procedures, especially in individuals still growing.

Adolescent↗

Some characteristics of endoscopic and radiological systems used in elaboration of the diagnosis of velopharyngeal incompetence.

The characteristics of rigid and flexible endoscopes have been studied with reference to their suitability for nasal pharyngoscopy in the assessment of velopharyngeal incompetence taking into account a number of fallacies which are known to exist. It is concluded that the ability to achieve correct positioning of the rigid endoscope and the wide angle field of view of the 70 degrees Storz-Hopkins nasopharyngoscope, in particular, made it the best single instrument at present available for this work despite the greater ease of introduction of the flexible endoscopes. The characteristics of the information obtained by radiological examination were studied and in comparison with endoscopic information it was concluded that endoscopic information was more reliable for qualitative and radiological for quantitative analysis. The systems were considered to be mutually complementary and simultaneous examination with, preferably, synchronous recording provided the advantages of optimal placement of the endoscope and the possibility of measurement of the velopharyngeal isthmus.

Barium Sulfate↗

Deterioration of cholestasis after endoscopic retrograde cholangiography in advanced primary sclerosing cholangitis.

Complications of endoscopic retrograde cholangiography specific to patients with primary sclerosing cholangitis have not yet been reported. We observed transient rises of serum bilirubin after diagnostic endoscopic retrograde cholangiography in five of 15 patients and persistent rises in three of 15 patients with primary sclerosing cholangitis examined consecutively by endoscopic retrograde cholangiography from 1985 to 1990. Deterioration of cholestasis was particularly associated with advanced disease. Seven of eight patients with deterioration after endoscopic retrograde cholangiography had septal fibrosis (stage III) or cirrhosis (stage IV) and a priori elevated serum bilirubin levels. In contrast, all patients with no deterioration of cholestasis following endoscopic retrograde cholangiography had early histological changes (stage I-II), and all but one patient had normal serum bilirubin levels. We conclude that the potentially harmful effects on biliary excretion must be taken into account when the use of endoscopic retrograde cholangiography is being considered in patients with advanced primary sclerosing cholangitis.

Adult↗

Endoscope decontamination: where do we go from here?

Thorough cleaning and disinfection or sterilization of endoscopes and associated equipment will reduce the likelihood of misdiagnosis and post-procedural infection. It will also prevent instrument deterioration and malfunction. With a rapid escalation in demand for endoscopy, particularly that associated with minimally invasive surgery, it is important that we have the processing technology to match the diagnostic and therapeutic value of these instruments without exposing staff and patients to unnecessary risk. Wherever possible staff should purchase heat tolerant endoscopic equipment that is readily accessible for cleaning. Automated processors, e.g. washer disinfectors and ultrasonic cleaners, improve the quality of the decontamination process but machines must have a self-disinfect function to prevent instrument recontamination during processing. Sterile, or filtered bacteria-free, water is essential for bronchoscopes and invasive instruments. Glutaraldehyde is still the most widely used disinfectant, particularly for the heat sensitive flexible endoscopes, but it is irritant and sensitizing and a safer alternative is sought. Peracetic acid is more rapidly efficacious and probably less irritant and, provided it does not damage endoscopes and processing equipment, may prove a suitable alternative. Unfortunately there are no nationally agreed test methods for assessing this and other new endoscope disinfectants and therefore no register of suitable or approved products. There is also no proven safe alternative to ethylene oxide for sterilizing invasive heat labile flexible endoscopes. It is important that, if toxic disinfectants and sterilants are used, staff and patients are suitably protected from exposure. Update training is essential for all processing staff if infection risks are to be minimized and sensitization problems avoided.

Cross Infection↗

Disinfection of endoscopes from Helicobacter pylori-positive subjects: evaluation of the effectiveness of the Chinese Calijing disinfection kit.

BACKGROUND: The aim of this study was to evaluate the effectiveness of the Calijing disinfection kit (an endoscope disinfection method used in Chinese hospitals) in eradicating Helicobacter pylori and assess whether use of the kit in 1994 during endoscopies in the Shandong Intervention Trial (SIT), Shandong, China, could have resulted in iatrogenic transmission of H pylori . METHODS: Bacterial culture studies at the Veterans Affairs Medical Center, Houston, Texas, using endoscopes and forceps from 49 H pylori -positive patients were performed on contaminated endoscopes before and after disinfection with the Calijing kit. RESULTS: At least 1 endoscope culture site was H pylori positive in 39 of 49 (79.6%) specimens predisinfection, whereas H pylori was not isolated from any endoscopic culture site postdisinfection. Non- H pylori bacteria and fungi were recovered from 22.6% of the postdisinfection cultures. CONCLUSION: Although no viable H pylori were recovered following the disinfection procedures, levels of H pylori below the detection threshold of the bacteriologic assay may have contributed to an increase in H pylori seroprevalence noted in the SIT. In addition, the kit was unable to provide disinfection against non- H pylori organisms, suggesting the need to adhere to internationally accepted disinfection procedures for endoscope reprocessing.

Cross Infection↗

Endoscopic resection of benign tumors of the duodenal papilla without and with intraductal growth.

BACKGROUND: Endoscopic papillectomy of benign papillary tumor is still not widely practiced. Intraductal growth has been considered a contraindication for endoscopic therapy. This prospective study evaluates endoscopic papillectomy for treatment of benign papillary tumors without and with intraductal growth. METHODS: Monofilament snare and monopolar electrocoagulation were used for papillectomy. A 7F stent was placed in the pancreatic duct. Patients with distal intraductal growth underwent sphincterotomy and endoscopic resection after exclusion of more proximal growth. RESULTS: Between February 1985 and April 2004, 106 patients (109 lesions), 68 women, 38 men, median age 68 years (range 29-88 years) were included. Median tumor size was 2 cm (range 0.5-6 cm) with one session (range 1-8) required for removal. Nine patients had invasive carcinoma (8%). Surgery for incomplete removal or recurrence was performed in 12% of 75 patients without and 37% of 31 patients with intraductal growth (p < 0.01), respectively. Fifteen patients had recurrence (15%); but, only 4 required surgery. Endoscopic resection was curative (median follow-up, 43 months) in 83% without and 46% with intraductal growth (p < 0.001). CONCLUSIONS: Endoscopic papillectomy is safe and effective, and may be feasible in cases of intraductal growth. Surveillance and, if required, re-treatment are mandatory because of the risk of recurrence.

Adult↗

Validity of the Rockall scoring system after endoscopic therapy for bleeding peptic ulcer: a prospective cohort study.

BACKGROUND: The Rockall scoring system was developed in unselected patients, the majority of whom did not receive endoscopic therapy. The aim of this study was to assess the validity of the Rockall system in high-risk patients who undergo endoscopic therapy for peptic ulcer hemorrhage. METHODS: Rockall scores were calculated in 247 patients with major peptic ulcer bleeding entered into a randomized trial of endoscopic therapy. The observed rates of recurrent bleeding and mortality after endoscopic therapy were compared with predicted rates derived from Rockall's study group. The validity of the Rockall system was assessed in terms of calibration and discrimination. RESULTS: Rates of recurrent bleeding and mortality after endoscopic therapy increased with an increasing Rockall score. Observed rates of recurrent bleeding and mortality were below predicted rates, and calibration of the Rockall system was poor (Mantel-Haenszel chi square = 25.8, p < 0.0001 for recurrent bleeding; Mantel-Haenszel chi square = 15.1, p < 0.0001 for death). For the prediction of recurrent bleeding, the area under the receiver operating characteristic curve was low (63.4%), but the system was satisfactory when predicting mortality (area under the resulting curve, 84.3%). CONCLUSIONS: After endoscopic therapy for a bleeding peptic ulcer, the Rockall scoring system can identify patients at high risk of death, but it is inadequate for the prediction of recurrent bleeding.

Aged↗

Endoscope disinfection using chlorine dioxide in an automated washer-disinfector.

Although 2% glutaraldehyde is often the first-line agent for endoscopic disinfection, its adverse reactions are common among staff and it is less effective against certain mycobacteria and spore-bearing bacteria. Chlorine dioxide is a possible alternative and an automated washer-disinfector fitted with this agent is currently available. This study was conducted to evaluate the effectiveness of chlorine dioxide in endoscopic disinfection after upper gastrointestinal examination. In vitro microbicidal properties of chlorine dioxide solutions were examined at high (600 ppm) and low (30 ppm) concentrations against various microbes including Pseudomonas aeruginosa, Helicobacter pylori, Mycobacterium avium-intracellulare and Bacillus subtilis in the presence or absence of bovine serum albumin (BSA). Immediately following endoscopic procedures and after application to the automated reprocessor incorporating chlorine dioxide at 30 ppm for 5 min, endoscopic contamination with infectious agents, blood, H. pylori ureA gene DNA and HCV-RNA was assessed by cultivation, sensitive test tape, polymerase chain reaction (PCR) and reverse transcriptase-PCR analysis, respectively. Chlorine dioxide at 30 ppm has equivalent microbicidal activity against most microbes and faster antimicrobial effects on M. avium-intracellulare and B. subtilis compared with 2% glutaraldehyde, but contamination with BSA affected the microbicidal properties of chlorine dioxide. Endoscopic contamination with microbes, blood and bacterial DNA was eliminated after application of the automated reprocessor/chlorine dioxide system. Thus, chlorine dioxide is a potential alternative to glutaraldehyde. The use of automated reprocessors with compatibility to chlorine dioxide, coupled with thorough pre-cleaning, can offer effective, faster and less problematic endoscopic disinfection.

Bacteria↗

Endoscopic vertical ramus osteotomy: early clinical results.

PURPOSE: The benefits of minimally invasive surgery have been well documented. The purpose of this report was to present early results in a series of patients who had endoscopic mandibular orthognathic surgery. Patients and methods This is a retrospective evaluation of 14 patients who underwent endoscopic vertical ramus osteotomy and rigid fixation for the treatment of mandibular prognathism (n = 9), malocclusion secondary to trauma (n = 3), or other pathology (n = 2). A 1.5-cm incision was made directly below the mandibular angle. The dissection was continued bluntly to the masseter muscle, which was incised using a needlepoint electrocautery. Then, with endoscopic elevators, an optical cavity was created for insertion of a Hopkins endoscope and visualization of the ramus/condyle unit. Anatomic landmarks were identified and the operation carried out with specially designed endoscopic equipment. Preoperative (T0), postoperative (T1), and follow-up (T2) clinical examinations; lateral cephalograms; and panoramic radiographs were used to evaluate the outcomes. RESULTS: The procedures performed included: vertical ramus osteotomy (n = 13 patients, 23 sides) and condylectomy plus vertical ramus osteotomy (n = 1 patient, 1 side). Mean operating time was 37 minutes per side. One patient had temporary marginal mandibular nerve weakness. The occlusal result was as planned in all cases. Panoramic radiographs documented postoperative ramus/condyle unit position and lateral cephalograms documented mandibular position. CONCLUSIONS: The results of this case series indicate that endoscopic vertical ramus osteotomy with rigid fixation is feasible for correction of a variety of mandibular deformities.

Adolescent↗

Endoscopic membranectomy with a high-frequency-wave snare/cutter for membranous stenosis in the upper gastrointestinal tract.

BACKGROUND/PURPOSE: As endoscopic equipment and instruments have been improved, the indication for endoscopic surgery has been extended. The authors achieved endoscopic membranectomy for congenital membranous stenosis in the upper gastrointestinal tract. METHODS: Case 1 was a 3-year-old girl with membranous stenosis in the descending duodenum. Case 2 was a 1-year-old boy with esophageal membranous stenosis. In case 1, a flexible endoscope with a banding chamber, the inside of which had a tiny groove for a high-frequency-wave snare, was inserted into the duodenum. The diaphragm was drawn into the chamber by endoscopic suction and tied with the snare around its base, then dissected by electrifying the snare. In case 2, the diaphragm was resected with a high-frequency-wave cutter, assisted by a balloon catheter pulling up the diaphragm from the distal side. RESULTS: In both cases, the stenosis was released adequately without complications, and oral feeding was restarted in a day after the procedure. CONCLUSIONS: Endoscopic membranectomy using a high-frequency wave snare/cutter was achieved safely and effectively in 2 children with congenital membranous stenosis in the upper gastrointestinal tract.

Child, Preschool↗

[What place for endoscopic sphincterotomy in treatment of acute pancreatitis?].

STUDY AIM: A prospective study was undertaken in order to evaluate the effects of endoscopic sphincterotomy on the evolution of biliary and idiopathic acute pancreatitis. PATIENTS AND METHODS: Among 320 patients with acute pancreatitis observed from 1986 to 1996, 118 were excluded from the study for etiological reasons and 137 were included for an endoscopic sphincterotomy within 72 hours from their admission. There were nine technical failures and 128 endoscopic sphincterotomies were performed. Sixty-five eligible patients were not included for logistic problems or patients' refusal; they can be considered as a "control group". RESULTS: The mortality rate of endoscopic sphincterotomy was 0 and the morbidity rate 2.1%. The mortality rate of acute pancreatitis was 3.1% in the sphincterotomy group vs 7.6% in the control group (P = 0.1) (NS) and the morbidity rate 25% versus 32% (P > or = 0.1) (NS). CONCLUSION: These results suggest that endoscopic sphincterotomy could be beneficial in acute biliary or idiopathic pancreatitis but they are not statistically significant. Endoscopic sphincterotomy does not increase the severity of acute pancreatitis and can be considered particularly in cases of gallstone pancreatitis but it should be performed less than 48 hours after the onset of acute pancreatitis.

Acute Disease↗

Histological correlates to pig gastrointestinal wall layers imaged in vitro with the magnetic resonance endoscope.

BACKGROUND & AIMS: The magnetic resonance endoscope consists of a nonferromagnetic endoscope with a receiver coil incorporated into its tip. The aim of this study was to define the anatomic correlates of the gastrointestinal wall layers imaged in vitro with the magnetic resonance endoscope. METHODS: Twenty-two tissue specimens from various segments of the porcine gastrointestinal tract were imaged with the magnetic resonance endoscope using up to four different scanning sequences. Cyanoacrylate, serving as a marker, was randomly injected into the tissue strips before imaging. Histological sections were then compared with the magnetic resonance images. RESULTS: T1-weighted spin echo sequences yielded the highest image quality and typically showed three wall layers that corresponded to distinct histological layers. The mucosa showed high signal intensity, the submucosa low signal intensity, and the muscularis propria an intermediate signal intensity. In the esophagus and rectum, the muscularis propria could be visualized as separate circular and longitudinal layers. CONCLUSIONS: In vitro imaging with the magnetic resonance endoscope shows three to five wall layers of the porcine gastrointestinal tract depending on the segment scanned. This degree of gut wall resolution suggests that endoscopic magnetic resonance imaging may have potential for local staging of gastrointestinal tumors.

Animals↗

Endoscopic transpapillary drainage of pancreatic abscess: technique and results.

BACKGROUND: Pancreatic abscess is one of the serious complications of acute pancreatitis. Traditionally, pancreatic abscess has been treated by operative drainage. Based on experience with endoscopic transpapillary drainage of pseudocysts, a similar technique was used in patients with pancreatic abscess. METHOD: Patients were evaluated by endoscopic retrograde cholangiopancreatography. In those with pancreatic abscess communicating with the main pancreatic duct, pancreatic sphincterotomy, saline irrigation of the abscess cavity, and catheter dilation followed by 10F pancreatic stent placement were done. Instillation of gentamicin and nasopancreatic catheter drainage were used in difficult cases. RESULTS: Of 22 patients with pancreatic abscess, 11 underwent endoscopic transpapillary drainage with technical success in 10 patients (90%); 8 patients (74%) had resolution of pancreatic abscess, clinically and radiographically. Intracavitary instillation of gentamicin and nasopancreatic catheter drainage were used in 2 patients. Two patients in whom endoscopic transpapillary drainage failed underwent operative drainage with a favorable outcome, and the one patient in whom endoscopic treatment was technically unsuccessful underwent successful percutaneous drainage. One patient had mild pancreatitis. CONCLUSION: Endoscopic transpapillary drainage is an effective nonoperative therapy for selected cases of pancreatic abscess and is associated with minimal morbidity and no mortality.

Abdominal Abscess↗

Endoscopic hemostatic treatment under irrigation for upper-GI hemorrhage: a comparison of one third and total circumference transparent end hoods.

BACKGROUND: Endoscopic hemostasis for upper-GI hemorrhage often is difficult to achieve if the view of the bleeding lesion is poor because of the presence of mucus, blood, and clots. An end hood that facilitates endoscopic hemostatic procedures while simultaneously allowing irrigation of the bleeding site was designed by us. Based on this design, a one-third partial irrigating end hood was developed, and its usefulness for treatment of non-variceal hemorrhage was evaluated. METHODS: The end hood was fabricated by drilling a side hole in the cap portion of a transparent end hood. An irrigation tube was glued to the exterior surface over the hole. A "total" (type 1) and a "one-third partial" (type 2) transparent end hood were fabricated. These differ with respect to the proportion of the endoscope circumference that is hooded by the device. The fabricated transparent end hood was placed on the tip of a standard endoscope. With the end hood in place, endoscopic hemostatic treatment under irrigation was performed in 35 patients (type 1 end hood, 18; type 2, 17) with non-variceal upper-GI hemorrhage. OBSERVATIONS: Hemostatic treatment was enhanced by simultaneous irrigation beneath the end hood, and hemostasis was successfully achieved in 34 of 35 cases. The time required to achieve hemostasis was significantly shorter in the type 2 group than the type 1 group (median 11.8 vs. 16.9 minutes; p < 0.05). CONCLUSIONS: The end hood was extremely useful for endoscopic hemostatic treatment under irrigation. The "one-third partial" end hood is superior to the total end hood in terms of duration of time required to achieve hemostasis.

Aged↗

Factors predicting failure of endoscopic injection therapy in bleeding duodenal ulcer.

BACKGROUND: The aim of this study was to assess the factors that may cause failure of endoscopic injection in patients bleeding from a duodenal ulcer. METHODS: One hundred twenty patients admitted for a bleeding duodenal ulcer with active arterial hemorrhage or a nonbleeding visible vessel were included. RESULTS: Endoscopic injection was not feasible in 14 of 120 (11.6%) patients because of inaccessibility or massive hemorrhage. The remaining 106 patients underwent endoscopic therapy by injection of adrenaline and polidocanol. The efficacy (achievement of definitive hemostasis) of endoscopy therapy was 83% (88 of 106). Univariate analysis showed that failure of endoscopic injection was related to age, presence of shock, ulcer size greater than 2 cm, and hemoglobin level. Multivariate analysis showed that ulcer size greater than 2 cm (p = 0.005) and the presence of shock (p = 0.03) were factors predictive of endoscopic treatment failure. Failure to achieve hemostasis (p < 0.001) and poor physical status measured by American Society of Anesthesiology classification (p = 0.02) were significantly related to mortality. CONCLUSIONS: Ulcer size and severity of hemorrhage are predictive of endoscopic injection failure in patients bleeding from high-risk duodenal ulcers. Survival is determined by clinical status and associated diseases.

Aged↗