Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Chlorophenols”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

Validated method for quantitation of biomarkers for benzene and its alkylated analogues in urine.

A validated gas chromatography-mass spectrometric method for the analysis of the metabolites of benzene and its alkylated analogues in urine is reported. A number of metabolites, as required by authorities for biomonitoring of industrial exposure to aromatic vapour, were analysed simultaneously with preservation of quantitative information concerning positional isomers. The use of this method replaces a combination of analytical methods required for the analysis of all these metabolites. Urine samples were subjected to acidic deconjugation followed by a derivatization step. Phenol, ortho-, meta-, para-cresol, mandelic acid, and ortho-, meta-, para-methylhippuric acid were analysed as their corresponding ethoxycarbonyl derivatives, with single ion monitoring. The mass-to-charge ratios (m/z) of the ions used for quantitation by single ion monitoring of the metabolites were: phenol, 94 m/z; cresols, 108 m/z; mandelic acid, 206 m/z; hippuric acid, 105 m/z; methylhippuric acids, 119 m/z. The mass-to-charge ratios for the internal standards were: [(2)H(6)]phenol, 99 m/z; p-chlorophenol, 128 m/z and 3-chloro-4-hydroxyphenyl acetic acid, 214 m/z. The limits of detection for phenol and the cresols were below 0.4 micromol/l and below 0.05 micromol/l for mandelic acid and the hippuric acids. Within-run precision for mandelic acid was 6.2%, for hippuric acid was 7.32% and was below 5% for the rest of the analytes.

Alkylation↗

Automatic on-line coupling of supercritical fluid extraction and capillary electrophoresis.

An interface for the automatic coupling of a supercritical fluid extractor (SFE) with capillary electrophoretic (CE) equipment, both commercially available, was developed with a view to improving sample treatment, which is a crucial step in capillary electrophoresis. Extracted analytes were collected in a trap following depressurization in the SFE and were transferred to the CE equipment across the interface. The key elements of the experimental assembly are a laboratory-made programmable arm and the autosampler of the CE equipment, both of which are controlled by a built-in microprocessor using an appropriate electronic interface and customized software. This combined system was successfully used to determine cresols and chlorophenols in liquid samples (river water and human urine) with increased precision, throughput, and automatability. The proposed arrangement opens up interesting prospects for the direct determination of analyte traces in solid samples without human intervention.

Journal Article↗

A two-color three-photon ionization scheme for the efficient and selective ionization of a chlorinated aromatic hydrocarbon.

A two-color three-photon ionization scheme, for the efficient and selective ionization of a chlorinated aromatic hydrocarbon that has an ionization potential higher than the two-photon energy of the laser used for excitation, is described. In this technique, an ultraviolet (UV) laser, i.e., the second harmonic emission of a fundamental (VIS) laser, is used for excitation and a UV and VIS laser for the subsequent two-photon ionization from the electronic excited state. A sample of o-chlorophenol was used as a model compound to demonstrate the advantage of this technique. The signal in supersonic jet/resonance-enhanced multiphoton ionization/mass spectrometry was increased approximately 4 times by the introduction of the VIS beam, when the polarization was adjusted to be parallel to the UV beam. Thus, the two-color three-photon (2UV+VIS) ionization scheme is more sensitive than one-color three-photon (3UV) ionization. The merits of this method over other ionization schemes such as two-color two-photon (UV(1)+UV(2)) ionization are discussed in terms of sensitivity and selectivity in spectrometric analysis.

Letter↗

Tetrabutylammonium-induced coacervation in vesicular solutions of alkyl carboxylic acids for the extraction of organic compounds.

The potential of the tetrabutylammonium-induced liquid-liquid-phase separation in alkyl carboxylic acid vesicular solutions for the extraction of organic compounds prior to liquid chromatography was examined for the first time. The behavior of the coacervates yielded from octanoic to oleic acids as a function of the pH and salts was investigated. The time required for phase separation depended on the length of the carboxylic acid alkyl chain and the experimental procedure (i.e., standing, sonication, centrifugation, stirring, etc.). Theoretical preconcentration factors were a function of both surfactant concentration and the length of the alkyl chain, and they greatly surpassed those obtained with other surfactant-mediated separations (e.g., surfactant-rich phases from dodecanesulfonic acid or Triton X-114). Parameters affecting the extraction efficiency were assessed. Analytes in a wide polarity/charge range, (e.g., PAHs, surfactants, chlorophenols, bisphenols, phthalates, herbicides, amines, dyes, and photographic developers) were extracted with high efficiencies on the basis of the different types of interactions that the vesicular coacervates can establish (i.e., hydrophobic and ionic interactions, hydrogen bonds, and formation of mixed aggregates). The coacervates were compatible with the chromatographic determination of analytes following UV or MS detection. Their suitability for working under real conditions was checked by applying them to the extraction of nonionic surfactants [alkylphenol ethoxylates (octyl and nonyl) and alcohol ethoxylates (C12-C16)] from raw and treated sewage and to river water samples. Analytes in the coacervate were separated and quantified by liquid chromatography-ion trap mass spectrometry. No cleanup steps were necessary. Recoveries of the target compounds in the environmental water samples ranged from 89 to 103%.

Journal Article↗

Broad spectrum analysis of 109 priority compounds listed in the 76/464/CEE Council Directive using solid-phase extraction and GC/EI/MS

A single multiresidue method was developed to determine 109 priority organic compounds included in the 76/464/EEC Council Directive on Pollution of the European Union. Such Directive includes 132 priority pollutants with a broad spectrum of polarities to be analyzed in drinking and surface waters, with the aim to protect water quality. From this list, the compounds analyzed included benzidines, chloroanilines, chloronitrobenzenes, chloronitrotoluenes, chlorophenols, chloronitrotoluidines, PAHs, PCBs, pesticides, phenylurea, and triazine herbicides. The method was developed in four steps. First, automated off-line solid-phase extraction using polymeric sorbent Oasis 60 mg cartridges was optimized to trap 109 compounds. Second, gas chromatography coupled to mass spectrometry with electron impact ionization (GC/EI/MS) was used in selected ion monitoring (SIM) mode for tentative identification of target analytes. Third, GC/EI/MS under full scan conditions was used for spectrum identification and analyte confirmation. Last, quantification was performed from SIM chromatogram using surrogates and internal standard. This method offered excellent sensitivity and selectivity, and the preconcentration of 200 mL permitted the achievement of limits of detection at the low nanogram/liter level and recoveries between 70 and 120%. Such methodology was applied to determine 109 organic compounds in French surface waters, and several pollutants were detected at levels from ppt to ppb. This multiresidue method developed was highly reproducible and robust and permitted a high sample throughput.

Journal Article↗

In-membrane preconcentration/membrane inlet mass spectrometry of volatile and semivolatile organic compounds.

The on-line determination of volatile and semivolatile organic compounds (SVOCs) is reported using membrane inlet mass spectrometry with in-membrane preconcentration (IMP-MIMS). Semivolatile organic compounds in aqueous samples are preconcentrated in a flow-through silicone hollow-fiber membrane inlet held in a GC oven. The sample stream is replaced with air, and the SVOCs are thermally desorbed into the mass spectrometer by rapid heating of the membrane. The method is evaluated for the on-line determination of 4-fluorobenzoic acid, 3,5-difluorobenzoic acid, 2-chlorophenol, p-tert-butylphenol, and dimethyl sulfoxide (DMSO) in water. The selectivity of the IMP-MIMS technique for SVOCs in the presence of VOCs is demonstrated. Cryotrapping and a rapid gas chromatographic separation step were added between the membrane and the mass spectrometer ion source for the determination of SVOCs in complex mixtures. The procedure is demonstrated for the determination of dimethyl sulfoxide (DMSO) in equine urine, using internal standardization with DMSO-d6. Full-scan electron ionization (EI) mass spectrometric detection showed good linearity (R = 0.998) and RSDs, relative to the internal standard, of 2.2% for desorption only and 4.6% for desorption and cryotrapping.

Animals↗

Perspectives on the formation of polychlorinated dibenzo-p-dioxins and dibenzofurans during municipal solid waste (MSW) incineration and other combustion processes.

The pathways by which polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are formed and the interactions between their aromatic precursors, in particular chlorophenols (ClPhs), and transition metal catalysts are discussed. A literature survey and data from pilot-scale combustion experiments allow conclusions to be drawn on the relations between ClPhs and PCDD/Fs in municipal waste incineration and other combustion processes. The results suggest that the ClPh pathway is among the most important for the formation of PCDD/Fs.

Benzofurans↗

How do organic solvents affect peroxidase structure and function?

The effect of organic solvents on horseradish peroxidase structure and function has been studied. Some, but not complete, enzyme denaturation occurs even in low volumes of water-miscible organic solvents (e.g., greater than 30% v/v dioxane, greater than 50% v/v methanol, and greater than 20% v/v acetonitrile) as determined by the decreased difference between the fluorescence of peroxidase's sole tryptophan residue and free L-tryptophan in solution. Absorbance and electron paramagnetic resonance spectroscopies indicate exposure of peroxidase's active site to the organic solvent. This reduces the local polarity in the enzyme's active site and results in stronger hydrogen bonding of phenolic substrates to the enzyme. In extreme cases (e.g., 95% v/v dioxane, 90% v/v acetonitrile, and ethyl and butyl acetate containing 2 and 1% v/v aqueous buffer, respectively), the transition state of the enzymic reaction is sufficiently perturbed so as to alter the magnitude of the Hammett rho value. This is most likely the result of the increased strength of hydrogen bonding between electron-donating alkoxyphenols (negative sigma values) and an electrophilic group in the enzyme's active site, thereby reducing catalytic efficiencies for such substrates relative to alkyl- and chlorophenols. Perhaps the most important effect of the organic solvent, however, is the significant ground-state stabilization of phenolic substrates in organic media as opposed to aqueous buffer. This stabilization can account for nearly 4 orders of magnitude in reduction of catalytic efficiency and is manifested in increased Km's. This study indicates that enzymes can maintain much of their native active-site structure in organic media and that the effect of solvent on substrate thermodynamics must be considered.

Acetonitriles↗

Experimental charge measurement at leaving oxygen in the bovine ribonuclease A catalyzed cyclization of uridine 3'-phosphate aryl esters.

The title esters are demonstrated to be specific substrates of bovine pancreatic ribonuclease A (EC 3.1.27.5). The Brønsted dependence of kcat/Km at pH 7.50 for the enzyme-catalyzed cyclization versus the pKa of the leaving phenol exhibits two regression lines of almost identical slope for respectively 2-chlorophenols and 2,6-unsubstituted phenols: log kcat/Km = -0.20 pKa ArOH + 5.47 (n = 5, r = 0.957); log kcat/Km = -0.17 pKa ArOH + 5.79 (n = 4, r = 0.965). Comparison of the Brønsted beta 1g's with that for the standard reaction where imidazole catalyzes the cyclization (beta 1g = -0.59) indicates considerably less development of negative charge on the leaving oxygen in the enzyme case, providing experimental evidence for the hypothesis that electrophilic assistance is involved in catalysis. The existence of two essentially parallel Brønsted correlations is not reflected in the standard reaction of substrate with imidazole. Modeling studies indicate that the phenyl ring of the substrate can take up a range of positions away from the active site; the presence of ortho chloro substituents considerably restricts the motion of the phenyl leaving group.

Animals↗

Protonation and deprotonation of the M, N, and O intermediates during the bacteriorhodopsin photocycle.

Transient pH changes were measured with phenol red and chlorophenol red in the 30-microseconds-50-ms time range during the photocycle of bacteriorhodopsin (BR), the light-driven proton pump. At pH greater than or equal to 7, the results confirmed earlier data and suggestions that one proton is released during the L----M reaction, and taken up again during the decay of N. These are likely to be steps in the proton transport process. At pH less than 7, however, the time-resolved pH traces were complex and indicated additional protonation reactions. The data were explained by a model which assumed pH-dependent protonation states for M and N which varied from -1 to 0, and for O which varied from 0 to + 2, relative to BR. If the kinetics of the vectorial proton translocation process were taken as pH independent, this treatment of the data suggested that a residue with a pKa of 5.9 was made protonable in M and N and two residues with pKa's of 6.5 were made cooperatively protonable in O. The additional protons detected are not necessarily in the vectorial proton transfer pathway (i.e., they are probably "Bohr protons"), and while they must reflect conformational and/or neighboring ionization changes in the BR as it passes through the M, N, and O states, their role, if any, in the transport is uncertain.

Bacteriorhodopsins↗

Indicator dyes as probes of electrostatic potential changes on macromolecular surfaces.

An indicator dye attached to an electrostatically charged macromolecular surface generally has a pK value (pKb') different from that of uncombined dye (pKf'). The question if changes in (pKb' - pKf'), designated as increment incrementpK, records changes in the electrostatic potential at the binding site has been examined in spectrophotometric and binding experiments, using the interaction of Chlorophenol Red and Phenol Red with human serum albumin and cationic micelles as examples. (1) In serum albumin solutions increment incrementpK is decreased by a reduction of pH. The decrease is correlated with the increase in positive charges on the protein molecule, and the response is attenuated by high ionic strength in accordance with electrostatic theory. (2) Opposite changes in binding affinity to serum albumin and increment incrementpK as a function of pH are observed; the binding of basic (bivalent anion) dye is more susceptible to a change in pH than in the acidic (univalent anion) form. (3) Preferential uptake of the basic as compared to the acidic form of dye is observed by binding to cetyltrimethylammonium chloride and cetylpyridinium chloride micelles (mu equals 0.033, [Cl-] equals 0.033 M). An increase in the ionic strength is accompanied by a positive value of increment incrementpK. The results are consonant with the view that the observed increment incrementpK values reflect changes in the electrostatic potential at the binding site with consequently little, if any, effect on the intrinsic pK. The extension of the method to measure changes in the electrostatic potential at binding sites on cell membranes is briefly discussed.

Bromthymol Blue↗

Color and toxicity removal following tyrosinase-catalyzed oxidation of phenols.

The products of phenol oxidation catalyzed by mushroom tyrosinase (polyphenol oxidase, EC 1.14.18.1) were assessed in terms of their residual color and toxicity. The addition of aluminum sulfate had little effect on the removal of colored products from phenol solutions treated with tyrosinase. Although chitosan was used successfully to remove the color when added before the reaction initiation or after the reaction completion, the required dose of chitosan was lower when it was added after the reaction. In this case, the minimum doses of chitosan required to achieve 90% color removal were proportional to the logarithm of the initial concentration of phenol. The color removal induced by chitosan addition appeared to be the result of chemical interaction followed by a coagulation mechanism. All treated solutions of phenol and chlorophenols, except 2,4-dichlorophenol, had substantially lower toxicities than their corresponding initial toxicities, as measured using the Microtox assay. Chitosan addition significantly enhanced the reduction in toxicity. The toxicities of the phenol solutions treated with tyrosinase were markedly lower than previously reported toxicities of solutions treated with peroxidase enzymes.

Agaricales↗

Use of olive oil for soil extraction and ultraviolet degradation of polychlorinated dibenzo-p-dioxins and dibenzofurans.

This paper represents a successful laboratory-scale photolysis of soil-bound tetra- to octachlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in olive oil. The irradiation source consisted of two blacklight lamps emitting light at a near-ultraviolet range. Samples used in the experiments included pure 1,2,3,4,6,7,8-heptachlorodibenzofuran, PCDD/F extract made of a wood preservative (chlorophenol product Ky 5), and soil that was highly contaminated with PCDD/Fs. Degradation of 1,2,3,4,6,7,8-heptachlorodibenzofuran dissolved in olive oil proceeded rapidlywith a first-order reaction half-life of 13 min. Irradiation of a soil sample resulted in an 84% reduction in PCDD/F toxicity equivalent (I-TEQ) in 17.5 h. A more complete degradation of soil-bound PCDD/Fs was achieved after extraction of the soil with olive oil. The oil was effective in solubilizing PCDD/Fs. After one extraction at room temperature, only 9% of I-TEQ remained in soil. Irradiation of the resulting extract reduced toxicity of the extract by 99%, and even the highly chlorinated congeners octachlorodibenzo-p-dioxin and octachlorodibenzofuran degraded easily (97 and 99% degradation, respectively). Photodegradation byproducts found included diphenyl ether and small amounts of dechlorination products, which were mainly nontoxic PCDD/Fs. Degradation was probably mediated by light absorption of unsaturated fatty acids and phenolic compounds in olive oil, leading to sensitized photolysis of PCDD/Fs.

Benzofurans↗

Determination of Henry's law constants of phenols by pervaporation-flow injection analysis.

A novel dynamic nonequilibrium technique for the determination of Henry's law constant (HLC) of phenols based on pervaporation-flow injection (PFI) is described. A linear relationship between HLC and the amount of phenol measured by a detector in the acceptor line of a PFI system was demonstrated. This relationship was constructed using five frequently encountered phenols (phenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 2-chlorophenol, and 2,3-dimethylphenol) and used for the determination of the HLC of three other phenols (2,4,6-trichlorophenol, 2-methylphenol, and 3-methylphenol). The HLC of all eight phenols were also determined by the single equilibrium static technique (SEST). Fairly good agreementwas observed between both techniques regarding the HLC of 2,4,6-trichlorophenol, 2-methylphenol, and 3-methylphenol. On the basis of the results obtained, it was concluded that the PFI technique offers considerable advantages over SEST in terms of precision, speed, labor intensity, and possibilities for automation.

Air↗

Selective trace level analysis of phenolic compounds in water by flow injection analysis--membrane introduction mass spectrometry.

Flow injection analysis coupled with membrane introduction mass spectrometry (FIA-MIMS) with on-line derivatization is shown to allow fast, accurate, nearly interference-free, and sensitive (low microgram/L) quantitation of phenolic compounds in water. On-line FIA derivatization of the phenolic compounds is performed by acetic anhydride acetylation in a K2CO3-buffered alkaline medium. The phenol acetates so formed efficiently permeate a silicone membrane and are directly transferred to the mass spectrometer, in which they are analyzed with selectivity and high sensitivity via selected ion monitoring. FIA-MIMS analysis was performed for aqueous solutions of phenol, 2-methylphenol, 4-chlorophenol, 4-chloro-3-methylphenol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol, and detection limits in the 0.5-20 micrograms/L (ppb) range were observed for an analytical frequency of six samples/h. FIA-MIMS for phenolic compound analysis is considerably less time-consuming and labor intensive than most chromatographic methods based on liquid-liquid extraction and preconcentration procedures and is therefore applicable for on-line and in-situ monitoring of phenols in wastewaters and in the environment. FIA-MIMS employing acetic anhydride derivatization is also virtually free of interferences since it combines chemical, membrane, and enhanced MS selectivity; hence quantitation of phenolic compounds can be performed in the presence of congeners.

Acetates↗

An isomer prediction model for PCNs, PCDD/Fs, and PCBs from municipal waste incinerators.

Isomer patterns of polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated biphenyls (PCBs), and polychlorinated dibenzofurans (PCDFs) from municipal waste incinerators (MWIs) were predicted by a model based on symmetry numbers and preferential chlorination positions. Fly ash isomer patterns from five stoker and seven fluidized bed incinerators were compared to validate the prediction model. The isomer patterns of the highly chlorinated PCN homologues from stoker type incinerators were successfully predicted. The relative equilibrium concentrations of tetrachloronaphthalenes (TeCNs), calculated by an ab initio method, cannot explain the field isomer patterns. Formation pathways involving chlorophenol precursor condensation reactions should be examined to see whether these isomer patterns provide a better fit to the field PCDD data. The PCB isomer patterns were fit reasonably well, but this finding could merely be an artifact of the limited data and the large number of isomers. The prediction equations of PCDFs, revised from prior work to include a symmetry number for each isomer, represented the field data patterns for the higher chlorinated isomers very well. Successful prediction of isomer patterns for partial homologue ranges suggests that these patterns are determined by a mechanism governed by Cl-position-specific preferences.

Benzofurans↗

Degradation of herbicide 4-chlorophenoxyacetic acid by advanced electrochemical oxidation methods.

The herbicide 4-chlorophenoxyacetic acid (4-CPA) has been degraded in aqueous medium by advanced electrochemical oxidation processes such as electro-Fenton and photoelectro-Fenton with UV light, using an undivided cell containing a Pt anode. In these environmentally clean methods, the main oxidant is the hydroxyl radical produced from Fenton's reaction between Fe2+ added to the medium and H2O2 electrogenerated from an 02-diffusion cathode. Solutions of a 4-CPA concentration <400 ppm within the pH range of 2.0-6.0 at 35 degrees C can be completely mineralized at low current by photoelectro-Fenton, while electro-Fenton leads to ca. 80% of mineralization. 4-CPA is much more slowly degraded by anodic oxidation in the absence and presence of electrogenerated H2O2. 4-Chlorophenol, 4-chlorocatechol, and hydroquinone are identified as aromatic intermediates by CG-MS and quantified by reverse-phase chromatography. Further oxidation of these chloroderivatives yields stable chloride ions. Generated carboxylic acids such as glycolic, glyoxylic, formic, malic, maleic, fumaric, and oxalic are followed by ion exclusion chromatography. The highest mineralization rate found for photoelectro-Fenton is accounted for by the fast photodecomposition of complexes of Fe3+ with such short-chain acids, mainly oxalic acid, under the action of UV light.

2,4-Dichlorophenoxyacetic Acid↗

Porous polysilsesquioxanes for the adsorption of phenols.

Arylene- and ethylene-bridged polysilsesquioxane materials have been synthesized by the hydrolysis and condensation of alkoxysilyl precursors under basic conditions. Cetyltrimethylammonium chloride was used to increase the porosity and surface areas of these materials via the surfactanttemplate approach. Structural characterization of these materials was carried out by nitrogen gas sorption and X-ray diffraction. The adsorption of three phenolic compounds (4-nitrophenol, 4-chlorophenol, 4-methylphenol) has been investigated by both batch and column testing. The arylene-bridged material exhibited a much greater affinity for all three phenols. The efficient removal of adsorbed phenols by a simple ethanol wash led to sorbent regeneration and separation of the aromatic species.

Adsorption↗