Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Aortic Dissection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

Clinical characteristics of hypotension in patients with acute aortic dissection.

To evaluate the clinical characteristics, risk factors, and outcomes of hypotension in unselected patients who had acute aortic dissection (AAD), we studied 1,073 such patients who were enrolled in the International Registry of Acute Aortic Dissection between 1996 and 2001. Hypotension was noted in 313 patients (29.2%) who had AAD (46.0% on admission). Multivariate logistic regression identified age >or=70 years (odds ratio [OR] 2.0, 95% confidence interval [CI] 1.4 to 2.9), type A dissection (referent type B AAD; OR 2.1, 95% CI 1.4 to 3.2), neurologic deficit (OR 3.8, 95% CI 2.2 to 6.6), syncope (OR 2.9, 95% CI 1.8 to 4.7), aortic regurgitation requiring valve surgery (OR 1.9, 95% CI 1.1 to 3.3), cardiac tamponade (OR 5.1, 95% CI 3.0 to 8.8), and new Q-wave or ST-segment deviation on an electrocardiogram (OR 1.6, 95% CI 1.1 to 2.4) as independent associations of hypotension (c statistic 0.78). Hospital complications (neurologic deficits 22.7% vs 12.0%, altered mental status 26.1% vs 4.4%, myocardial ischemia 14.6% vs 6.9%, mesenteric ischemia 6.9% vs 2.6%, or limb ischemia 14.6% vs 6.9%, and death 55.0% vs 10.3%) occurred more frequently in patients who had hypotension than in those who did not (p <0.001 for all comparisons). We concluded that hypotension that occurred in >25% of patients who had AAD was associated with a much higher rate of in-hospital adverse events. Our study also identified factors associated with hypotension in patients who had AAD.

Acute Disease↗

Large area of the false lumen favors secondary dilatation of the aorta after acute type A aortic dissection.

BACKGROUND: Since 1994 patients with acute aortic dissection type A (AADA) are followed-up in our outpatient clinic. Early diagnosis of secondary dilatation of the diseased aorta is crucial to reduce late mortality in these patients. Aim of the present study is to asses the impact of a large volume in the false lumen of the diseased downstream aorta on secondary dilatation. METHODS AND RESULTS: 134 patients of 264 patients who underwent surgery for AADA (between January 1994 and June 2003) are followed-up at our outpatient clinic since 1994. 84 patients (62.7%) fulfilled the inclusion criteria. Areas of the true and the false lumens of the aorta were analyzed and a logistic regression was calculated at 5 levels of the aorta for each patient. Patients were divided in 3 groups: group 1 included 34 patients (40.5%) without progression, group 2 had 34 patients (40.5%) with slight progression, and group 3 had 16 patients (19.0%) with important progression, requiring surgery in all patients. In 87.5% of the patients the area of the original lumen was <0% in group 3, compared with 11.8% in group 2 and 8.8% in group 1 in relation to the total area of the aorta 6 months after surgery (P<0.001). CONCLUSIONS: A large false lumen, with an area of the true lumen <30% 6 months after surgery, is the strongest predictor for secondary dilatation of the diseased downstream aorta.

Acute Disease↗

Late aortic root redissection following surgical treatment for acute type A aortic dissection using Gelatin-Resorcin-Formalin glue.

OBJECTIVES: Although Gelatin-Resorcin-Formalin (GRF) glue is widely used in surgery for acute aortic dissection, late complications possibly due to the glue, such as late aortic root redissection, have also been reported. We have experienced similar complications, some of which required redo surgeries, and these cases are reviewed. METHODS: Twenty-six consecutive patients who underwent surgery for acute type A aortic dissection using GRF glue, from December 1996 to February 2001, were retrospectively studied, with a special focus on any late complications and any reoperation. RESULTS: Of the 21 patients who survived and were followed as outpatients, false aneurysms were found in 5 patients (21%) at 24-42 (mean 34) months following the initial surgery. Of these, 2 patients required resternotomy because of the increasing aneurysm diameter. In both cases, the aortic root was redissected at the site of the GRF glue use where the anastomosis between the aortic root and the prosthesis had widely opened and had become the aneurysm entry point. Significant aortic regurgitation was noticed in 3 patients (14%, 1 of whom showed a false aneurysm), and 2 of these underwent reoperation for aortic root redissection. CONCLUSIONS: A high incidence of aortic root redissection with false aneurysm and/or aortic insufficiency was found following the surgery for acute aortic dissection using GRF glue. These patients should be carefully followed for years after surgery.

Aged↗

Spontaneous aortic dissecting hematoma in two dogs.

This report describes 2 cases of spontaneous aortic dissecting hematoma in young Border Collie and Border Collie crossbred dogs. Histology was performed in one of the cases involving an unusual splitting of the elastin present within the wall of the aorta, consistent with elastin dysplasia as described in Marfan syndrome in humans. The first case involved a young purebred Border Collie that died suddenly and the second case involved a Border Collie crossbred dog that died after a 1-month history of seizures. Gross lesions included pericardial tamponade with dissection of the ascending aorta in the former case and thoracic cavity hemorrhage, mediastinal hematoma, and aortic dissection in the latter. Histologic lesions in the case of the Border Collie crossbred dog included a dissecting hematoma of the ascending aorta with elastin dysplasia and right axillary arterial intimal proliferation.

Aortic Dissection↗

Painless aortic dissection presenting as high paraplegia: a case report.

Acute aortic dissection is a catastrophic episode that usually presents as a sudden, painful, ripping sensation in the chest or back. Physical findings may include loss of pulses and aortic regurgitation. It is associated with neurologic sequelae in as many as one third of patients. Painless dissection occurs in 5% of patients. We report a case of painless aortic dissection, presenting as acute paraplegia. The patient was a 77-year-old woman who presented with paraplegia, with no chest or back pain. On examination, strength was 5/5 in both upper extremities and 0/5 in both lower extremities. Deep tendon reflexes were absent in her legs. She had no voluntary anal contraction. Sensation was absent from T6 through S5. Computed tomography of the chest revealed a type A dissecting aneurysm. The vascular supply to the spinal cord and the differential diagnosis for new onset paraplegia are discussed.

Aged↗

Complex intimal flaps in acute aortic dissection.

A 43-year-old man was emergently admitted and diagnosed as acute aortic dissection (Stanford type A). While being prepared for emergent operation he fell into hemodynamic hazard with repeated ventricular fibrillation and loss of consciousness. Massive aortic regurgitation and coronary disturbance due to a back-and-forth movement of an intimal flap through the aortic valve were the causes of the cardiogenic catastrophy. In addition, a completely torn intimal flap was intussuscepted into the origin of the brachiocephalic artery. This was thought to disturb the cerebral perfusion. Acute aortic dissection with such complex intimal flaps is very rare. In such cases cardiopulmonary bypass should be established to maintain the patient's cardiac function as soon as possible after diagnosis and the operation should be performed with sufficient brain protection.

Acute Disease↗

[Surgical therapy of thoracic aortic dissection].

Considerable surgical progress of treating aortic dissection has been achieved during the past decade. The emergency indication for acute dissection of the ascending aorta (type A according to the Stanford classification) is unquestioned while surgical treatment for acute dissection of the descending aorta (type B dissection) is mainly reserved for complicated cases. The major complication of acute operations--fatal hemorrhage from the suture line and secondary multi-organ failure--have been successfully reduced by a progress of cardiopulmonary bypass techniques, the introduction of cold cardioplegic myocardial protection, the development of modern suture materials and glues and last not least by a continuous intensive monitoring. Especially the introduction of the so-called french glue safely enabled both the closure of the false lumen as well as the strong reinforcement of the diseased aortic wall and seems to offer a reliable alternative to the application of multi-layered teflon strips. Since the principle of all reconstructive approaches in case of dissection consists of closure of dissected layers and the limited replacement of the segment that is susceptible to a rupture the exact readaptation and reinforcement of the diseased aortic wall represents a fundamental operative step. In type A operations the supracoronary aortic prosthetic replacement or the combined replacement of ascending aorta plus aortic valve followed by the reattachment of coronary arteries has become the standard operative technique. In fact, independently from the location of the primary intimal tear the operation has been traditionally limited to replace the ascending aorta in order to remove an aortic segment that is most likely to rupture. Yet an increasing number of follow-up investigations has demonstrated recurrence of dissection or an aneurysmatical dilatation of the false lumen in about 20% of patients treated with ascending aortic replacement. Consequently, repair of the aortic transverse arch and the radical elimination of the intimal entry is now favoured by an increasing number of surgeons. In addition to these various perioperative and intraoperative adjuncts the introduction of new imaging techniques, especially computerized tomography, magnetic resonance imaging and transesophageal echocardiography allowed to establish adequate therapeutical concepts on a more rational basis. Transesophageal echocardiography as a mobile diagnostic device enables investigators to perform a bed-side dynamic visualization of both the location and extent of a dissection, the evaluation of ventricular performance and aortic competence. Treatment of acute type B dissection is mainly conservative unless complications like intractable pain, aneurysmatic enlargement of the false lumen, ischemia of visceral organs or even rupture occur.(ABSTRACT TRUNCATED AT 400 WORDS)

Anastomosis, Surgical↗

Subtotal thoracic aortic replacement as reoperation for ruptured aortic dissection: report of a case.

We report successful repair of a ruptured chronic aortic dissection in a 63-year-old female who had undergone end-to-end anastomosis for acute type A dissection 8 years before. The patient had hypotension with back pain and cough. A computed tomogram revealed a large chronic aortic dissection (Stanford type A) and complete atelectasis of the left lung due to hemothorax. The brachiocephalic artery was also dissected and aneurysmal. Emergency surgery was performed. Subtotal thoracic aortic replacement with reconstruction of 4 cervical vessels was carried out using hypothermic circulatory arrest with selective cerebral perfusion via a redo-sternotomy and a left anterolateral thoracotomy. The patient was discharged from the hospital without any sequelae.

Aortic Dissection↗

A case of aortic dissection caused by blunt chest trauma.

A 74-year-old woman was struck by a car travelling at about 50 km/h. On arrival at hospital, a CT scan showed dissection of the ascending and descending aorta. She collapsed and died suddenly 8h later. At autopsy, there was massive bleeding into the left pleural cavity, ruptures of the pericardium and right ventricle, and a type A thoracic aortic dissection. The cause of death was haemorrhagic shock due to rupture of the pericardium and delayed rupture of the right ventricle following trauma to the chest. The thoracic aortic dissection was not the direct cause of death although histological examination did reveal that it occurred in the accident. Traumatic aortic dissection is rare although traumatic aortic rupture is a major cause of death after blunt chest trauma. This paper discusses the mechanisms, and factors involved in aortic dissection caused by blunt trauma.

Accidents, Traffic↗

Acute thoracic aortic dissection presenting as sore throat: report of a case.

Acute dissection of the aorta can be one of the most dramatic of cardiovascular emergencies. Its symptoms can occur abruptly and progress rapidly. Prompt recognition and appropriate intervention is crucial. However, not all aortic dissections present with classic symptoms of abrupt chest, back, or abdominal pain, and the diagnosis may be missed. Aortic dissection presenting as a sore throat is quite unusual. A 53-year-old man presented with sore throat as the early symptom of an acute thoracic aortic dissection. Unfortunately, the diagnosis was delayed, and the patient died. Given the high morbidity and mortality after delayed recognition or misdiagnosis, aortic dissection should be considered in the differential diagnosis of a patient presenting with sore throat and normal findings of neck and throat, even when there is no classic symptoms.

Aortic Dissection↗

Aortic root necrosis after surgical treatment using gelatin-resorcinol-formaldehyde (GRF) glue in patients with acute type A aortic dissection.

BACKGROUND: Although gelatin-resorcinol-formaldehyde (GRF) glue is used for surgical repair of acute type A aortic dissections, late complications possibly ascribed to toxic effects of GRF glue have been reported. We analyzed the benefits and risks of using GRF glue. PATIENTS AND METHODS: Between January 1990 and August 2003, 269 consecutive patients underwent emergency operations for acute type A aortic dissection. GRF glue was not used in 47 patients (non-GRF group) who were operated on until May 1995 and was used in the 222 (GRF group) who underwent operation subsequently. RESULTS: The rate of in-hospital mortality was significantly higher in the non-GRF group (31.9%) than in the GRF group (12.6%) (p<0.0001). In the GRF group, false aneurysms were found in 31 patients (31/194 survivors, 16.0%) 1-65 (mean, 30+/-18) months after initial operation. Reoperation was done in 24 of these patients. At reoperation, the site to which GRF glue was applied had degenerated, and the anastomosis between the aortic root and prosthesis had opened widely, creating a false aneurysm and resulting in aortic regurgitation with prolapse of the coronary cusps. The mortality rate of reoperation was 4.2% (1/24). CONCLUSION: The use of GRF glue improved the short-term outcome of surgery for acute type A aortic dissection, but was associated with a high incidence of false aneurysms forming at the site of proximal anastomosis, where GRF glue had been applied. Patients in whom GRF glue has been used should be carefully followed up after surgery.

Acute Disease↗

[A successful surgical case report of acute aortic dissection involving entire sinus of Valsalva].

We successfully performed aortic root replacement for acute aortic dissection, Stanford type A involving the entire sinus of Valsalva, associated with acute anterior wall myocardial infarction and aortic valve insufficiency. A 57-year-old man was admitted complaining of chest pain. An emergency operation was performed after a perfusion catheter was inserted to 99% stenotic lesion of the left anterior descending artery (LAD) on the same day. The dissection extended to both ostia of the coronary arteries and disrupted all commissures of the aortic valve, resulting in severe prolapse of the aortic valve leaflets. Aortic root replacement was performed using a valved conduit. The left main coronary artery was reattached to the graft using interposition technique with a 8 mm diameter woven Dacron tube graft. In addition, the LAD and right coronary artery were bypassed using saphenous vein. The postoperative course was uneventful and the patient was discharged from hospital on the 35th postoperative day. Retaining no aortic sinus and adequate coronary artery reconstruction is important for surgical repair of aortic dissection involving the entire sinus portion of the ascending aorta.

Aortic Dissection↗

[A successful treatment for myonephropathic metabolic syndrome after operation of acute aortic dissection (Stanford type A) with multiple organ ischemia].

A 60-year-old man had sudden chest pain and right lower extremity pain. A diagnosis of acute aortic dissection (Stanford type A) with right lower extremity ischemia was made. An emergency ascending aortic and total arch replacement, right axillo-femoral bypass, and coronary artery bypass grafting was performed for acute aortic dissection, acute right iliac arterial occlusion, and acute myocardial infarction. Myonephropathic metabolic syndrome (MNMS) occurred 2 days after operation. The serum creatine kinase value increased over 68,000 U/l, hemodiafiltration was started on the 2nd postoperative day (POD). The patient fell into anuric state and hemodiafiltration was performed 3 times a week. Urination was obtained over 1,000 ml/day from the 25th POD and hemodiafiltration was not necessary any more. We emphasize that prompt operation including revascularization of ischemic leg should be performed in acute aortic dissection with extremity ischemia and also prompt hemodiafiltration to improve the prognosis of these disastrous lesion.

Acute Disease↗

[Acute aortic dissections. Hospital outcome of 186 cases].

PURPOSE: To determine in hospital outcome acute aortic dissection patients. METHODS: We revised 186 consecutive cases (up to 14 days of dissection), in a period of 6 years. The patients were divided according to Daily's classification (types A and B). RESULTS: Type A--127 cases: a) 75 were surgically treated (37 died); b) 2 were medically treated (both died); c) 39 died before the definitive treatment could be initiated; d) 11 died misdiagnosed or undiagnosed. The total mortality was 70.0%. Type B--59 cases: a) 11 complicated cases were surgically treated (6 died); b) 40 were medically treated (8 died); c) 7 died before the definitive treatment could be initiated; d) one died misdiagnosed. The total mortality was 37.25%. In summary, 41.4% of the patients survived. 28.4% died despite the definitive treatment, 24.7% died before the definitive treatment could be initiated and 6.4% died without the correct diagnosis. CONCLUSION: The acute aortic dissection is a dramatic situation, mainly type A. In this type of dissection many patients (41%) died misdiagnosed, undiagnosed or without enough time to surgical therapy. So, an earlier diagnosis and treatment are imperative.

Acute Disease↗

Is extended arch replacement for acute type a aortic dissection an additional risk factor for mortality?

BACKGROUND: We report our experience with surgery for acute type A aortic dissection with involvement of the aortic arch. METHODS: From January 1986 to December 2001, 277 patients underwent surgery for acute type A aortic dissection. In 70 patients (25.3%), surgery was extended into the aortic arch: hemiarch and total arch replacement in 53 (75.7%) and 17 (24.3%) patients, respectively. Deep hypothermic circulatory arrest was used in 19 patients, antegrade selective cerebral perfusion in 38, and combined deep hypothermic circulatory arrest with antegrade selective cerebral perfusion in 13. RESULTS: Operative mortality was 18.6% (13/70) after extended replacement into the arch versus 21.7% (45/207) after surgery limited to the ascending aorta (p = 0.62). Multivariate analysis did not reveal significant risk factors for operative mortality. Postoperatively, 5 patients (8.1%) had a new postoperative cerebral vascular accident (CVA). Multivariate analysis showed an earlier date of operation as the only independent determinant for a new postoperative CVA (p = 0.0162, RR = 0.80/year, 95% CI = 0.67 to 0.96). None of the patients, operated on with antegrade selective cerebral perfusion, had a new cerebral deficit. Comparing the different methods of cerebral protection, multivariate risk analysis revealed antegrade selective cerebral perfusion as a significant protective factor against new postoperative CVA (p = 0.0110, OR = 0.12, 95% CI = 0.02 to 0.61). Survival at 5 and 10 years was 66.6.5% and 40.0%, respectively, after replacement of the aortic arch versus 68.7% and 57.7%, respectively, after replacement of the ascending aorta (p = 0.96). Freedom from aortic arch reoperation was 96.3% at 5 and 77.0% at 10 years versus 86.6% and 75.1% in both groups, respectively (p = 0.21). CONCLUSIONS: Extended replacement into the aortic arch during surgery for acute type A dissection does not influence early and late results. The best cerebral protection seems to be obtained with antegrade selective cerebral perfusion.

Acute Disease↗

Surgical treatment of DeBakey type I aortic dissection using the "elephant trunk technique".

OBJECTIVES: To review the indications, operative methods and postoperative management of the "elephant trunk technique", and to report two cases of DeBakey type I aortic dissection treated with the "elephant trunk technique". METHODS: Two cases of DeBakey type I aortic dissection were operated with selective cerebral perfusion via the right subclavian artery. At the first stage, a tubular dangling aortic graft prosthesis ("elephant trunk") was inserted into the distal aorta while replacing the ascending aorta and aortic arch. The distal elephant trunk prosthesis was then used at the second stage involving the replacement of the sections of the distal aorta via a left-sided thoracotomy. RESULTS: The two operations were successful. Ultrafast computed tomograph (UFCT) showed that the two patients were cured after the first stage operation, and the second stage procedure could have been avoided. CONCLUSIONS: The "elephant trunk technique" is a multiple stage approach in the treatment of extensive aneurysmal diseases of the aorta. The procedure is indicated for patients who have combined diseases of both ascending aorta plus aortic arch segments and descending aortic aneurysm. It can also be used for patients with DeBakey type I aortic dissection. Some patients can be cured after the first stage operation.

Aortic Dissection↗

Surgery for aortic dissection involving an aberrant right subclavian artery.

On diagnosis of Stanford type A acute aortic dissection with an aberrant right subclavian artery, emergency operation was performed. Aortic arch replacement was undertaken with additional 'elephant trunk' procedure to cover the entry site and decrease the blood flow through the false lumen. We consider this technique will become one of the effective procedures for acute aortic dissection involving an aberrant right subclavian artery.

Aortic Dissection↗

Replacement of the transverse aortic arch during emergency operations for type A acute aortic dissection. Report of 26 cases.

In type A aortic dissection, the intimal disruption is located on or extends to the transverse arch in about 20% of patients. Replacement of the arch may then be necessary to avoid leaving an unresected, acutely dissected aorta and to prevent bleeding, progression of aneurysm, rupture, and ultimately reoperation or death. From 1970 to September 1987, 119 patients were operated on for type A acute dissection. Starting in January 1977, gelatin-resorcin-formaldehyde biologic glue was used in 91 patients to reinforce the dissected tissues at the suture sites. Among these 119 patients, 26 (ages 32 to 76 years) underwent replacement of the transverse aortic arch in addition to replacement of the ascending aorta. In 20 patients cerebral protection was achieved by profound hypothermia (16 degrees to 20 degrees C) associated with circulatory arrest (15 to 40 minutes, mean 27 minutes) during the distal anastomosis. In six patients the carotid arteries were selectively perfused with cold blood (6 degrees C) during moderate core hypothermia (28 degrees C) while cardiopulmonary bypass was discontinued (19 to 34 minutes, mean 25 minutes) to allow the prosthesis to be sutured without the distal aorta being cross-clamped. Moderate hypothermia avoided the long rewarming time necessitated by profound hypothermia. The hospital mortality rate was 34% (9/26). Two of the 20 patients subjected to profound hypothermia and circulatory arrest died during the operation and seven patients died of postoperative complications. No deaths or major complication were observed in the other six patients. Follow-up of the 17 survivors ranges from 3 to 90 months (mean 39). One patient died 6 months after the operation of cerebral hemorrhage. One patient is disabled by neurologic sequelae. Fifteen patients are in good clinical condition (New York Heart Association class I or II). Postoperative aortograms in 12 patients, and computed tomographic scans in all, have shown a stable repair of the transverse arch in all survivors but a persisting dissection of the descending aorta in 11 (70%). Growing experience and improving results in emergency operations for type A aortic dissection have led us to extend the replacement of the aorta to the transverse arch whenever necessary. The gelatin-resorcin-formaldehyde glue has proved to be an efficient adjunct. The best cerebral protection was obtained in our experience by carotid perfusion with cold blood during circulatory arrest at moderate core hypothermia.

Acute Disease↗