Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

[Acute appendicitis. Preoperative observation time and diagnostic accuracy].

The indication for operative treatment of suspected acute appendicitis is based mainly on clinical examination. In this retrospective study of 327 emergency laparotomies the accuracy of the surgeons diagnosis was 69.4%. The overall rate of unnecessary laparotomy was 28.4%, and 45.6% of the operated females, aged 12 to 40 years, did not actually require surgery. The median postadmission delay before operation was three hours 28 minutes. With increasing observation time, the diagnostic accuracy was significantly decreased from 77.7 to 52.2%, and the incidence of perforation rose from 18.6 to 33.3%. 8.7% of the patients with a surgical condition suffered from excessive delay (greater than 12 hours) before surgery. There was no correlation between time of admission and operation and accuracy of diagnosis, but a considerable variation in accuracy between different surgeons. The difficulty in obtaining a correct pre-operative diagnosis in patients with suspected acute appendicitis is still a clinical problem of major concern.

Acute Disease↗

Accuracy of dynamic perfusion CT with deconvolution in detecting acute hemispheric stroke.

BACKGROUND AND PURPOSE: Dynamic perfusion CT (PCT) with deconvolution produces maps of time-to-peak (TTP), mean transit time (MTT), regional cerebral blood flow (rCBF), and regional cerebral blood volume (rCBV), with a computerized automated map of the infarct and penumbra. We determined the accuracy of these maps in patients with suspected acute hemispheric stroke. METHODS: Forty-six patients underwent nonenhanced CT and dynamic PCT, with follow-up CT or MR imaging. Two observers reviewed the nonenhanced studies for signs of stroke and read the PCT maps for TTP, MTT, rCBF, and rCBV abnormalities. Sensitivity, specificity, accuracy, and interobserver agreement were compared (Wilcoxon tests). Nonenhanced CT and PCT data were reviewed for stroke extent according to previously reported methods. Sensitivity, specificity, and accuracy of the computerized maps in detecting ischemia and its extent were determined. RESULTS: Compared with nonenhanced CT, PCT maps were significantly more accurate in detecting stroke (75.7-86.0% vs. 66.2%; P <.01), MTT maps were significantly more sensitive (77.6% vs. 69.2%; P <.01), and rCBF and rCBV maps were significantly more specific (90.9% and 92.7%, respectively, vs. 65.0%; P <.01). Regarding stroke extent, PCT maps were significantly more sensitive than nonenhanced CT (up to 94.4% vs. 42.9%; P <.01) and had higher interobserver agreement (up to 0.763). For the computerized map, sensitivity, specificity, and accuracy, respectively, were 68.2%, 92.3%, and 88.1% in detecting ischemia and 72.2%, 91.8%, and 87.9% in showing the extent. CONCLUSION: Dynamic PCT maps are more accurate than nonenhanced CT in detecting hemispheric strokes. Despite limited spatial coverage, PCT is highly reliable to assess the stroke extent.

Adult↗

The diagnostic accuracy of fine needle aspiration cytology versus core needle biopsy for palpable breast lump(s).

OBJECTIVE: Breast lump is one of the most common surgical problems in females. Surgical biopsy of palpable breast lump was considered the gold standard for the diagnosis of breast lump(s). Emphasis has been placed on improving method for establishing a definitive diagnosis of breast mass prior to surgery. Our aim was to compare the diagnostic accuracy of fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with palpable breast masses. METHODS: Prospective randomized controlled clinical trial included 296 Female patients with breast lumps, presented to Al-Thawra Teaching Hospital, Sanaa, Yemen between May 1998 -- May 2002. All the patients submitted either to FNAC or CNB equally. The results were then compared with the final diagnosis by histopathology. RESULTS: The patient age ranged from 15-74 years with a mean of 33.77 +/- 11.91 years. Married patients were 69.3% and the most common presentation was breast lump(s) (88.5%). The mean size of the tumor was 3.47 +/- 1.43 cm in diameter. The FNAC sensitivity was 66.66%, 81.8% specificity, 75.7% accuracy, positive predictive value (PPV) 100% and negative predictive value (NPV) 90%, while in core needle breast biopsy sensitivity was 92.3%, 94.8% specificity, 93.4% accuracy, PPV 100% and NPV 100%. The diagnostic accuracy of CNB was higher than the FNAC, which was statistically significant (p<0.05). CONCLUSION: Both procedures are simple, easy, safe, cheap and reliable, but CNB is more accurate than the FNAC.

Adolescent↗

[Improvement in accuracy of quantitative assessment of the regional cerebral blood flow with 99mTc-ECD].

Mean cerebral blood flow (mCBF) in the slice including the basal ganglia (reference slice) is necessary for the quantification of regional CBF using Patlak plot and BUR methods on 99mTc-ECD cerebral perfusion SPECT. The mCBF was calculated from the mean counts of this slice. A region of interest (ROI) has been manually set on the reference slice to obtain the mean counts (manual ROI method). However, there was large variability observed in the value of rCBF in this method. We developed a 3DSRT method for improving the accuracy of the mean counts in the reference slice and evaluated the difference between the value of rCBF on manual ROI method and that on 3DSRT method in consecutive 11 patients with cerebral vascular disease. Difference in the value of mean counts of the reference slice was distributed within the 2 standard deviations (SD) with Blant-Altman analysis in 9 of 11 patients. Significant difference in the value of mean counts between two methods was observed in 2 of 11 patients. 3DSRT method is superior accuracy to the manual ROI method in the evaluation of the counts in the ROI. Lower accuracy in manual ROI method, therefore, results in the difference of the value of mean counts. 3DSRT method provides high accuracy with the various quantitative methods for the evaluation of rCBF using 99mTc-ECD.

Aged↗

Accuracy of assessing infrabony defects using a special digital filter for periodontal bone loss.

PURPOSE: To assess the accuracy of linear measurements of bone loss within infrabony defects on digitized radiographs after digital filtering particularly designed to image periodontal bone loss. METHODS: Before surgery, 50 standardized radiographs of 50 infrabony defects were obtained. Intrasurgically the distances from the cementoenamel-junction (CEJ) to the alveolar crest (AC), from the CEJ to the bottom of the bony defect (BD), and the depth of the infrabony component (INFRA) were assessed. All radiographs were digitized and the distances CEJ-AC, CEJ-BD, and INFRA were measured on digitized but unchanged radiographs and after use of the filter. RESULTS: There was a small overestimation of CEJ-AC (0.35-0.68 mm) and underestimation of CEJ-BD (0.84-1.12 mm) and INFRA (0.66-0.76 mm). Accuracy of measurement of the distance CEJ-AC was influenced by vertical angulation difference (P= 0.047) and the intrasurgical CEJ-AC (P= 0.003). Accuracy of CEJ-BD was influenced by intrasurgically assessed bone loss (P= 0.012). Accuracy of INFRA was influenced by individual patient, intrasurgically assessed INFRA (P< 0.001), and filter (P= 0.018).

Adult↗

Accuracy of diabetes diagnosis in health insurance claims data in Taiwan.

BACKGROUND AND PURPOSE: There are limited data from Taiwan about the accuracy of National Health Insurance (NHI) claims data. This study assessed the accuracy of NHI claims data for diabetes and its associated factors. METHODS: Insurance claims data for patients with a diagnosis of diabetes were extracted from the records of the Bureau of National Health Insurance, including detailed files of the outpatient, emergency, inpatient and pharmacy treatment records from January 1, 2000 to December 31, 2000. A stratified, 2-staged, probability proportional to size and equal probability method was used to sample 9000 diabetes patients. The accuracy of the diabetes diagnosis was assessed based on patient responses to questionnaire items. Subjects with negative or uncertain questionnaire answers who had hypoglycemic agents in pharmacy claims data were also classified as diabetic. RESULTS: A total of 1350 questionnaires were returned and an accurate diagnosis was verified from data in 1007 (74.6%) of these subjects. Univariate analysis showed that level of accreditation of the hospital, age, gender, follow-up department, type of complication, number of outpatient visits, emergent visit, as well as hospitalization were significant factors associated with an accurate diagnosis of diabetes. Multivariate logistic regression analysis revealed that number of outpatient visits, hospitalization, age, and the level of accreditation of the hospital were significant independent factors. The odds ratio of an accurate diagnosis increased with the number of outpatient visits and hospitalization. The probability of accurate diagnosis of diabetes among patients with >/= 4 outpatient visits was 99.16 times greater than that of patients with </= 1 outpatient visit. The probability of accurate diagnosis in patients with >/= 1 hospitalization was 5.26 times that of patients who had not been hospitalized. CONCLUSIONS: This study found that the accuracy of diabetes diagnosis in NHI claims data in Taiwan was 74.6%. Further attention to the association of inaccurate claims in cases with infrequent outpatient visits, young age and those attending non-accredited hospitals is needed in order to address the efficiency of diagnosis and surveillance of diabetes in Taiwan.

Adult↗

[The research on accuracy of computer-assisted surgery].

The computer-assisted surgery system is a complex system. All of the errors can be attributed to the loss of correspondence between the world coordinate system in the operation room and the virtual world coordinate system obtained from the multi-model medical images. The system's accuracy is composed of the accuracy of the localizer and that of registration. In order to improve the system accuracy, we analyse most of the possible error sources. The accuracy of the localizer affects deeply the registration between the intra-operation and pre-operation data. The localizer is the most basic and important part for a computer-assisted surgery system. We give a comprehensive possible error source at the end of the paper.

Algorithms↗

[Correlation of effective temporal resolution and accuracy of volume ejection fraction on the ECG-gated cardiac MDCT].

PURPOSE: ECG-gated cardiac MDCT offers many cardiac clinical applications. The goals of this report are 1) to introduce a new concept of effective reliability (ER) from effective temporal resolution for the evaluation of ejection fraction (EF) and evaluation of image quality (IQ) of coronary arteries, and 2) to show the correlation of ER and the accuracy of EF with different cardiac reconstruction algorithms and different rotation speeds. METHODS AND MATERIALS: To assess the accuracy of EF, helical scanning was performed with a gated cardiac MDCT (GE LightSpeed, 8/16 slice) on pulsating cardiac coronary phantoms (0.5 and 0.6 sec rotation speed for each 50-110 bpm, 5-bpm step). We define effective reliability (ER) from effective temporal resolution (%) as follows: ER= (1-TR/HC) x 100; TR: Effective temporal resolution, HC: time of heart cycle in each bpm. RESULTS: From the results of the EF measurement and calculated ER, high accuracy was obtained by using optimal scan conditions (optimal rotation speed and cardiac reconstruction algorithm) in a wide range of heart rates (heart rate<90: EF & ER>81%; heart rate<110 bpm: EF & ER>73%). Results showed that the calculated ER is closely correlated with the measurement results of EF based on the phantom experiment (R2=0.901+/-0.075; Max: 0.994, Min: 0.738). Optimal reconstruction thickness can reduce total image number for the evaluation of EF. CONCLUSION: We concluded that the ER is useful to evaluate EF accuracy and the IQ of images of coronary arteries.

Electrocardiography↗

Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice computed tomography coronary angiography.

PURPOSE: To assess the effect of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). MATERIALS AND METHODS: One hundred patients (88 males; 59+/-11 years) with suspected coronary artery disease who had undergone conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA, with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 2.8 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol 320 mgI/ml at 4 ml/s and the scan delay was defined with a bolus tracking technique. In all patients vascular enhancement was measured in the aortic root, and in the left and right coronary arteries. The average vascular enhancement was used to divide the population in two groups of 50 patients each, one with lower enhancement (Low), and one with higher enhancement (High). In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (= or >50% lumen reduction) was evaluated in vessels = or >2 mm in diameter using quantitative CA as the reference standard. The differences in diagnostic accuracy were compared with a Chi-square test and a p<0.05 was considered significant. RESULTS: Of the total 1116 segments (= or >2 mm lumen diameter), 173 presented significant stenosis. The sensitivity and specificity for the assessment of significant stenosis were 89.4% and 93.3% vs 94.3% and 97.4% in the presence of increasing intravascular enhancement, 92.8% and 96.7% vs 91.1% and 93.9% in the presence of increasing heart rate, and 89.7% and 97.6% vs 93.3% and 92,8% in the presence of an increasing calcium score. CONCLUSIONS: Increasing intravascular enhancement significantly improves diagnostic accuracy in MSCT-CA. A higher heart rate lowers the specificity in the detection of significant obstructing lesions of the coronary artery. An increasing calcium score determines a lower specificity and a higher sensitivity.

Aged↗

Accuracy of ultrasound in the detection of liver fibrosis in chronic viral hepatitis.

PURPOSE: To assess the accuracy of ultrasonography (US) in the identification and grading of hepatic fibrosis in patients afflicted with chronic viral liver disease, compared to histological examination as a gold standard. MATERIALS AND METHODS: We prospectively studied 105 patients (32 F, 73 M) affected by chronic viral liver disease in 36 months. Patients were studied with B-mode US and then underwent US-guided liver biopsy. All the patients were studied with conventional US with a Sequoia 512, 6.0 (Acuson, Mountain View CA, USA). We evaluated the following US parameters: liver margins, parenchymal echotexture, portal vein caliber and spleen diameter. The four B-mode US parameters were used for the US grading (from 0 to 4). Scheuer's grading (from 0 to 4) was used for the histological score. Grades 3 and 4 were considered as positive for fibrosis. Sensitivity, specificity, positive and negative predictive values and accuracy were calculated in the case of absence, positivity of one or all the US parameters. The correlation between US and histological scores was evaluated with Spearman's test. RESULTS: At histology seventy-seven patients (73%) had absent grade 0 (1 patient; 1%), low-moderate grade 1 (35 patients; 33%) or grade 2 (41 patients; 39%) liver fibrosis. Twenty-eight patients (27%) had severe grade 3 (16 patients; 15%) or grade 4 (12 patients; 11%) fibrosis. In the case of absence of US parameters sensitivity was 32%, specificity 32%, positive predictive value 15%, negative predictive value 57% and accuracy 32%. In the case of positivity of at least one of the US parameters the values were 68%, 68%, 43%, 84% and 69%. In the case of presence of all the US signs the results were 25%, 100%, 100%, 79% and 80%. None of the 77 patients with a healthy liver or with low-grade fibrosis was positive for all the US parameters. All the patients positive for all of the ultrasonographic parameters had high-grade fibrosis or cirrhosis at liver biopsy. Correlation between B-mode and histological scores was not statistically significant (Rs=0.45; p=0.0001). CONCLUSIONS: US identification of liver fibrosis in chronic liver disease is possible with 25% sensitivity, 100% specificity, 100% positive predictive value and 79% negative predictive value, with an 80% diagnostic accuracy.

Biopsy, Needle↗

Dimensional accuracy of a new polyether impression material.

OBJECTIVES: The purpose of this study was to evaluate the dimensional accuracy of stone dies produced from standardized impressions with 1 new and 1 conventional polyether impression material and a polyvinyl siloxane reference material. METHODS AND MATERIALS: Impressions with the polyether materials P2 and Impregum and with the polyvinyl siloxane Flexitime were produced at 23 degrees C or 37 degrees C from a truncated steel cone in cylindrical steel trays giving 4-mm impression layer thickness at the prominence line. Stone dies were poured after 1 or 24 hours of storage at ambient atmosphere. Additional impressions were stored at different relative humidity levels (0%, 33%, 50%, 75%, or 100%) for 24 hours prior to die pouring. The accuracy of the stone dies was determined as axial discrepancy between a steel ring, which fit perfectly on the steel die and the occlusal die surface. The base-diameter deviation (deltad) was calculated. RESULTS: After 1 hour, a similar increase in deltad was noticed for impression materials when dies were poured at impression temperature. Impressions made at 37 degrees C exhibited significantly higher deltad than at 23 degrees C. Light-bodied P2 showed the highest deltad increase when dies were poured after 24 hours. Flexitime showed moderate deltad differences at the 2 pouring times. The deltad of dies made from polyether materials decreased significantly with increasing humidity, whereas polyvinyl siloxane was not adversely affected. CONCLUSION: The dimensional accuracy of P2 is comparable to that of the conventional polyether impression material after short-term storage. Polyethers may absorb water, significantly compromising die accuracy upon storage at high humidity.

Absorption↗

[To inquiry into clinical-pathological factors influencing cytological accuracy of pancreatic head lesions].

OBJECTIVE: To inquiry into clinical-pathological factors influencing cytological accuracy of pancreatic head lesions. METHODS: Cytology was retrospectively evaluated in 94 inpatients with a mass in head of pancreas existing with chronic pancreatitis in the past decade, the results of cytology were compared with clinical pathology or clinical follow-up to estimate the value and accuracy of cytology in detecting pancreatic cancer. Pancreatic clinical-pathology includes size of mass and component of mass which was composed of cancerous mode of development including shape of conglomeration, nest and pervasion, and pancreatic ductal epithelium inside the vicinity of 1 cm around the mass. Pancreatic ductal epithelium were divided into PanIN1, PanIN2 and PanIN3 three types according to classified criterion of pancreatic intraepithelial neoplasia (PanIN). RESULT: Forty-six patients were pathologically diagnosed as pancreatic cancer and five patients as chronic pancreatitis, accordingly, 29 malignant, 5 suspicious, 10 atypical hyperplasia among of them 5 malignant, 3 hyperplastic ductal epithelium, 1 nondiagnostic results due to interfered by blood and 3 insufficient specimens. 43 patients were clinically diagnosed as chronic pancreatitis. Cytologic evaluation of pancreatic cancer has an 84.2% accuracy less than or equal to 2.5 cm and 71.9% larger than 2.5 cm. Shape of conglomeration, and nest have more accurate than pervasion in cytological diagnosis. CONCLUSIONS: Cancerous mode of development is a vital factor influencing accuracy of cytology, cytological estimation of atypical hyperplasia and is still waiting for further investigation.

Adult↗

[Accuracy of preoperative magnetic resonance imaging in prediction of pathological stage and circumferential resection margin in rectal cancer].

OBJECTIVE: To evaluate the accuracy of preoperative magnetic resonance imaging (MRI) in prediction of pathological staging and involvement of circumferential resection margin (CRM) in rectal cancer. METHODS: Fifty-three patients undergoing total mesorectal excision for biopsy-proven rectal cancer were assessed prospectively using high-resolution MRI for tumour (T) and mesorectal nodal (N) staging as well as CRM status using the depth of tumour spread, tumour node metastasis and CRM involvement. Preoperative MRI assessment of these prognostic factors was compared with the histopathological findings in carefully matched whole-mount sections of the specimen. RESULTS: MRI correctly staged the tumor in 41 patients, understaged in 8, and overstaged in 4. The accuracy of T stage was 77.4% (41/53). There was ageneric correlation between pathologic and MRI tumor staging (Kappa = 0.602, P < 0.001). Node status was correctly staged in 37 patients, overstaged in 10, and understaged in 6. The accuracy of node staging was 69.8% (37/53), sensitivity was 75% (18/24), and specificity was 65.5% (19/29). The correlation between pathologic and MRI node staging was poor (Kappa = 0.399, P = 0.003). The CRM status was correctly reported in 51 patients, overstaged in 1, and understaged in 1. The accuracy of CRM status was 96.2% (51/53), sensitivity was 80% (1/5), and specificity was 97.9% (47/48). There was a good correlation between pathologic and MRI CRM involvement (Kappa = 0.779, P < 0.001). CONCLUSION: Preoperative MRI provides poor predictive data as to subsequent pathologic tumor and mesorectal node stage, but does produce reliable prediction of clear CRM.

Adult↗

[Ways to improve measurement accuracy of blood glucose sensing by mid-infrared spectroscopy].

Mid-infrared (MIR) spectroscopy is applicable to blood glucose sensing without using any reagent, however, due to a result of inadequate accuracy, till now this method has not been used in clinical detection. The principle and key technologies of blood glucose sensing by MIR spectroscopy are presented in this paper. Along with our experimental results, the paper analyzes ways to enhance measurement accuracy and prediction accuracy by the following four methods: selection of optimized spectral region; application of spectra data processing method; elimination of the interference with other components in the blood, and promotion in system hardware. According to these four improving methods, we designed four experiments, i.e., strict determination of the region where glucose concentration changes most sensitively in MIR, application of genetic algorithm for wavelength selection, normalization of spectra for the purpose of enhancing measuring reproduction, and utilization of CO2 laser as light source. The results show that the measurement accuracy of blood glucose concentration is enhanced almost to a clinical detection level.

Blood Glucose↗

[Analysis of the accuracy of a coronary syndrome register].

Registers of the management of infarction can complement information obtained from randomised trials evaluating the methods and practice of treatment. In order to do this, the quality of the registers must be assured, and in particular the accuracy of the recorded cases. The objective of this study was to evaluate the accuracy of a register for the in-hospital and pre-hospital management of acute coronary syndromes with ST segment elevation of less than 12 hours' duration. Using a capture-recapture method, the study compared cases in the register with eligible cases present in the hospital and emergency ambulance service databases at two establishments, giving a recruitment rate of 61%. The rate of accuracy was estimated at 84% (95% CI [82 ; 86]). The independent factors associated with failure of notification were female sex (ORa=6.65 [2.04-21.69]), presentation at nights, weekends or bank holidays (ORa=4.13 [1.33-12.85]), direct admission to hospital without passing by the emergency ambulance service (ORa=2.85 [1.03-7.69]), primary angioplasty (ORa=6.18 [1.60-23.79]) and the absence of reperfusion (ORa=40.38 [6.21-262.40]). With more than 80% accuracy, the results produced by the register are robust. The selection bias linked to the under-representation of certain subgroups, while real, has only a marginal impact on estimates derived from the register. Factors associated with failure of notification should be taken into account when operating such a register.

Angina, Unstable↗

Student accuracy and evaluation of a computer-based audience response system.

We have incorporated an audience response system into our curriculum to increase student interaction in the teaching process. Classroom Performance System (CPS) is a computer-based audience response system that allows students to answer questions posed to the entire class by entering responses on a keypad. The responses are tallied and displayed on the classroom screen for all students to see. The purpose of our study was to determine student accuracy using the system with three different methods of administering questions. A secondary purpose was to assess students' perceptions about using the system. Our hypothesis for the study was that there should be no difference in volunteer accuracy or questionnaire responses to the three methods of gathering responses. Sixty-two dental students volunteered to participate. Using three methods (projected on a screen, verbal, and written), volunteers were given "responses" to enter into the system using CPS wireless remote answering devices. In the projected and verbal formats, the teacher managed the assessment by controlling the pace of input. In the written format, students were given responses on paper to input into the system at their own pace. At the end of the sessions, volunteers completed an anonymous questionnaire regarding their experiences with the system. The accuracy of responses was similar in the teacher-managed assessments (projected and verbal format). There was a statistical difference in the accuracy of responses in the student-managed assessment (p=<0.000001). Questionnaire responses also showed that students preferred teacher-managed assessments. The hypothesis was disproved. The overall response to this audience response system and its methods of gathering information was very positive.

Analysis of Variance↗

Accuracy of cytologic diagnosis of central nervous system tumours in crush preparation.

The aim of this study was to assess the usefulness and accuracy of cytologic smears by making crush preparation as a diagnostic method, in central nervous system tumors. 278 patients with central nervous system tumors were investigated. In 98 cases, material was obtained intraoperatively during craniotomy and in 180 cases stereotactic biopsies were done. In all the cases crush preparations were made, and cytologic diagnosis was correlated with final histologic diagnosis. 244 out of 278 patients showed correlation with histopathological diagnosis. So, in present study diagnostic accuracy was 87.76%. In 18 cases no definite diagnosis was made due to inadequate material. Majority of the patients were in age group 31 to 40 years (72 cases). The youngest patient was three years old and the eldest was 87 years old. The most common tumor in intracranial cavity was astrocytoma (56.68%), followed by meningioma (6.88%), medulloblastoma (5.66%) and ependymoma (5.56%). The most common tumor in intraspinal cavity was ependymoma (38.46%), followed by meningioma (23.07%) and schwannoma (23.07%). In conclusion, crush preparation is an effective, simple, rapid, relatively safe and reliable technique for the diagnosis of central nervous system tumors. Diagnostic accuracy of cytology with final histopathological report is established with accuracy rate of 87.76%.

Adolescent↗

[Hospital morbidity statistics: the accuracy of the diagnosis reported in the discharge registry book].

BACKGROUND: The registry book of admission and discharges (RBD) is operative in most public and private hospitals of this country. Currently its reformation is contemplated, consisting in a modification of the minimal set of basic data and its computerization. The aim of the present study was to evaluate the accuracy of the discharge diagnosis recorded in the RBD and to analyze the possible factors implicated in the current quality level. METHODS: In a sample of 9 hospitals from the Seville province, 2,634 discharges were selected with a stratified sampling process which was proportional to the number of discharges in each stratum during 1985. The accuracy of the diagnosis recorded in the RBD was estimated by comparing it with that in the clinical record (CR). RESULTS: The accuracy indexes showed that, for the large diagnostic groups, only in 45% of discharges the diagnosis coincided in both documents. The accuracy increased to 89% when the estimation was made after excluding those discharges where the diagnosis was not recorded in the RBD and/or in the CR (n = 1303). CONCLUSIONS: The fulfillment of the RBD appears as the main error source, followed by the selection of the major diagnosis and its transcription in the different documents of the circuit. It is concluded that a precondition for the success of a reformed RBD is to guarantee the fulfillment of data.

Diagnosis↗