Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

A silicone rubber spacer used to determine the optimum thickness for hard and resilient materials in complete dentures.

When making a denture with a resilient lining, the problem of controlling the thickness of the resilient lining material is eliminated by use of a spacer. However, controlling the thickness of the hard acrylic resin denture base in these dentures remains a problem and may increase the possibility of fracture. When limited denture space is available, the portions of the denture base subject to fracture should have an accurate if not equal share of the resilient lining material and the hard acrylic resin material. This procedure will minimize the fracture problem of dentures made with resilient lining and is an alternative to conventional spacer procedures.

Acrylic Resins↗

Comparative methodological investigations on the cytochemical localization of calcium in brain and inner ear of cichlid fish.

Four different methods for calcium precipitation are compared in the optic tectum and the inner ear of the cichid fish, Oreochromis mossambicus. Several parameters are investigated concerning their influences on the reaction product. Three procedures (bichromate, fluoride, and oxalate-pyroantimonate) produce fine-grained deposits, often flocculent in the latter method. The fourth method (potassium-pyroantimonate) generates predominantly coarse-grained reaction product. The calcium content of the deposits is always proven with energy-filtering transmission electron microscopy (EFTEM). In both tissues fine-grained reaction product is found in endoplasmic reticulum and synaptic vesicles, and in addition in some mitochondria and at the cytoskeleton. The coarse-grained deposits of the potassium-pyroantimonate method have a more unspecific distribution. This is the only method which produces extracellular deposits in the inner ear, whereas in the optic tectum extracellular precipitates are always present except with the oxalate-pyroantimonate procedure. Two factors have an influence on the reaction product: the duration of fixation and the type of resin. The prolongation of the fixation time up to 24 hours leads to an increase of the reaction product, which also becomes coarse-grained. These observations are corroborated by quantification with image analysis. Furthermore the use of an epoxy resin compared to acrylic resins decreases the amount of reaction product produced. We show that the application of several methods is meaningful in order to understand the calcium properties of the investigated tissue, but it is necessary to optimize a certain method for a given tissue.

Animals↗

Comparison of the accuracy of denture bases by a non-parametric method.

A comparison of the accuracy of denture bases made from a conventional acrylic and four modified acrylic resins was made with the use of a non-parametric method. Twenty-five identical maxillary stone casts were made and five dentures for each resin were processed by conventional compression moulding techniques. The fit of each denture at the molar-to-molar region on its cast was evaluated by five evaluators who independently ranked the twenty-five dentures from best to worst fit after processing, after polishing, and after storage in water at 37 degrees C for 42 days. The ranking data were analysed by Kendall's coefficient of concordance, the Kruskal-Wallis statistic, and the Mann-Whitney test. Excellent agreement among observers was obtained. After storage in water, two modified acrylic resins, Hydrocryl and Vitalon II, had a better fit on their casts than the conventional acrylic, Lucitone Hypro. Luciton 199 had the same and Hircoe had a poorer fit than Lucitone Hypro.

Acrylic Resins↗

[Properties of polyfluoroethylene-copolymers for the denture base lining material (author's transl)].

Silicone rubber is conventionally used as a lining soft material for denture base. However it still has some properties to be improved, such as poor adhesive strenth with acrylic resin, discoloration, degradation and growth of candida. We attempted to apply chemically-stable polyfluoroethylene-copolymers for this purpose. The terpolymers consisting of difluoroethylene, tetrafluoroethylene and chlorotrifluoroethylene (or hexafluoropropylene) were prepared and tested for tensile strenth, adhesive strength to acrylic resin, water sorption, contact angle, shore hardness, and toxicity by hemolysis test, cell culture test and extraction test. One of the selected terpolymer showed less water sorption (0.1 mg/cm2), stronger tensile strength (160 kg/cm2) and adhesive strength (110 kg/cm2) than the silicone rubber lining material. The toxicity test results suggested that the terpolymer will pose a low potential acute toxicity in vivo. All the test results seem to suggest that the polyfluoroethylene elastomer described here is a promising soft liner material for denture base.

Acrylic Resins↗

[Chest wall reconstruction with a prosthetic material molded from a extirpated specimen].

A new molding technique of the Acryl-resin Marlex-mesh sandwich method is described. After the wide extirpation of the chest wall, the defect size tends to grow up more larger than the specimen. For making a just fit size prosthesis, we cut off a cardboard as the same size as the specimen and the Acryl-resin Marlex sandwich is molded from the cardboard. Other some know-how are in the text.

Acrylic Resins↗

Light-weight ocular prosthesis.

The authors propose a variation of the technique for making ocular protheses for large ophthalmic cavities introducing an expanded polystyrene (styrofoam) to the acrylic resin at the time of making the prosthetic sclera, aiming at reducing the weight of the prosthesis and thus improving mobility and aesthetics. This study compares the differences in weight, absorption of water and resistance to rupture by hydrostatic pressure of the pieces made of acrylic resin, chemically activated, heat activated and cross-linked by the proposed technique and by the technique for hollow ocular prothesis. The proposed technique presents advantages in manufacturing time and handling of the material.

Acrylic Resins↗

A comparison of resins for fabricating provisional fixed restorations.

Four acrylic resins and two composite resins for fabricating provisional fixed prosthodontic restorations were studied to determine temperature change during polymerization, surface hardness, marginal fit, wear resistance, transverse strength, transverse repair strength, surface roughness and polishability, color stability, and stain resistance. While certain materials exhibited advantageous properties in one or more of the tests, no one material was superior to the others in all tests.

Acrylic Resins↗

Strength improvement of critical-sized three dimensional printing parts by infiltration of solvent-free visible light-cured resin.

The use of light-cured acrylate resin as an infiltrant can enhance flexural modulus and flexural strength of natural polymers based three dimensional printing (3DP) parts to be closed to general use of polymethyl methacrylate resin. It was observed that flexural properties of infiltrated specimens were influenced by infiltration conditions. Curing by normal halogen light bulb was more practical for critical-sized 3DP parts than curing by typically small probe of dental visible light curing unit (VLC). Similar levels of flexural properties were obtained from these two methods. Post-heated treatment after curing was also observed to further increase the flexural modulus and strength of infiltrated samples. However, flexural strain at break was not affected by different curing conditions. Preliminary In Vitro toxicity test of infiltrated 3DP parts showed that the cells which were in contact with samples were healthy. No inhibition zone was observed.

Acrylic Resins↗

In vivo and in vitro studies on soft denture materials: microbial adhesion and tests for antibacterial activity.

The microbiological properties of four tissue conditioners, one soft liner, and one acrylic resin were studied. The tissue conditioners showed no or negligible antimicrobial effects toward salivary microorganisms by two different in vitro tests. In in vitro adhesion experiments, more Streptococcus mutans and Candida albicans adhered to the tissue conditioners and the soft liner in comparison with conventional acrylic resin used for denture-base fabrication. No difference in bacterial adhesion was found among the tissue conditioners. The microbial colonization of two tissue conditioners lined on maxillary dentures in three volunteers was followed for 14 days. No difference among the materials was found, but a tendency for subject-dependence in plaque formation on the materials was noted.

Acrylic Resins↗

Force versus time profiles of selected heat-processed denture liners.

The potential correlation of the force versus time behavior of four resilient lining materials and their acceptance by patients was investigated. Two modified acrylic resins and two silicone denture lining materials were tested. The response of the soft lining materials to a programmed indentation test was used to define a parameter for each denture liner product. A parameter defined as the "Rebound Index," using force-time data obtained from the indentation measurements, was significantly different for the modified acrylic resins compared to the silicone materials. Improved patient acceptance was correlated with higher values of this index.

Acrylic Resins↗

A technique for fabrication of a cheek recontouring prosthesis.

A technique has been described for fabrication of a removable prosthesis that restores proper cheek contour. This prosthesis is a modified removable partial denture with a retentive surface to hold an acrylic resin bolus to recontour the cheek from within. The advantages of such a prosthesis for the patient with facial nerve paralysis include restoration of fullness and proper contour to the cheek (Figs. 7 and 8), prevention of trauma to the buccal mucosa during mastication, and stretching of the cheek, which indirectly improves oral hygiene in the buccal sulcus. The disadvantages of this technique include limited improvement in esthetic and functional contour of the cheek, and food accumulation beneath the acrylic resin bolus, which requires more meticulous hygiene.

Acrylic Resins↗