Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Reference Standards”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68Linked to original sources

MR angiographic and sonographic indications for endarterectomy.

PURPOSE: Our objective was to determine whether appropriate criteria could be developed for performing an endarterectomy on the basis of sonographic and MR angiographic findings. METHODS: Fifty patients were examined prospectively with sonography, MR angiography, and conventional angiography. All three imaging studies were performed within 2 weeks of one another, and conventional angiography served as the reference standard. RESULTS: All 10 carotid occlusions were detected with sonography and MR angiography. Sonography accurately showed flow in two arteries, and MR angiography showed flow in one of three nearly occluded arteries with extremely slow flow. Multislab three-dimensional time-of-flight MR angiographic sequences underestimated the degree of stenosis in 12 arteries, and in two cases this resulted from high T1 signal within the atherosclerotic plaque. With conventional angiography as the reference standard for 70% to 99% stenosis, sonography had a sensitivity of 96%, a specificity of 91%, and a positive predictive value of 90%, while concordant sonographic findings and the presence of a signal void on multislab 3-D time-of-flight sequences had a sensitivity of 72%, a specificity of 98%, and a positive predictive value of 97%. CONCLUSION: Endarterectomy performed on the basis of sonographic findings of 70% to 99% stenosis and of a signal void on multislab 3-D time-of-flight MR angiographic sequences is appropriate.

Adult↗

A time to be born.

OBJECTIVES: This study used a large, population-based data set (n = 619,455) to establish reference standards of the timing of spontaneous vaginal births. METHODS: Low-risk births in Massachusetts from 1989 to 1995 were studied. This group comprised 242,276 births that met the following criteria: singleton, vertex, vaginal births with a birthweight of between 2500 and 4000 g; gestation between 37 and 42 weeks; a 5-minute Apgar score greater than 6, and no induction or stimulation. RESULTS: Low-risk births displayed a mild circadian pattern, with a peak between 11:00 AM and 1:00 PM and a trough between 11:00 PM and 1:00 AM. Subgroup analysis showed no clear differences except for parity. CONCLUSIONS: Reference standards should be developed and used as comparative norms for hospital and practice-based perinatal studies of diurnal patterns of birthing.

Circadian Rhythm↗

Evaluation of sustained-action chlorpheniramine-pseudoephedrine dosage form in humans.

This investigation compared the bioavailability of chlorpheniramine and pseudoephedrine from a sustained-action capsule and a combination of two reference standard tablets in 24 normal human subjects. The capsule contained 8 mg of chlorpheniramine maleate and 120 mg of pseudoephedrine hydrochloride, and the tablets each contained half of the amount of the chlorpheniramine or pseudoephedrine in the capsule. Because the capsule was a combination product, a new study design had to be developed to accommodate steady-state conditions for both drugs. Each subject received the capsule (every 12 hr) and the combination of the reference tablets (every 6 hr) for 8 days according to a two-way crossover design. Serial blood and urine samples were taken during the entire study. Plasma and urine samples were assayed for chlorpheniramine and pseudoephedrine by sensitive and specific high-pressure liquid chromatographic or GLC methods. There were no significant differences in the plasma concentration profiles of chlorpheniramine and pseudoephedrine at all times, except when the capsule developed peaks or the tablets developed nadirs. The highest mean peak plasma concentrations for the capsule and the tablets were 38.7 and 32.9 ng of chlorpheniramine/,ml and 525 and 515 ng of pseudoephedrine/ml, respectively. The mean biological half-lives of chlorpheniramine and pseudoephedrine were 21.6 and 8.0 hr, respectively. The AUC and unchanged drug excreted in urine, after a single dose and at steady state, showed that the sustained-action capsule (given every 12 hr) and the reference standard tablets (given every 6 hr) were bioequivalent.

Adult↗

Captopril-enhanced 99Tcm-MAG3 renal scintigraphy in subjects with suspected renovascular hypertension.

This pilot study was undertaken to generate preliminary data on the accuracy of captopril-enhanced renal scintigraphy with a relatively new radiopharmaceutical, 99Tcm-mercaptoacetyltriglycine (99Tcm-MAG3) for detecting significant renal artery stenosis. Truth data was based either on arteriographic or outcome criteria (blood pressure response to therapy). Twenty-seven subjects with suspected renovascular hypertension were studied with baseline and captopril-enhanced 99Tcm-MAG3 renal scintigraphy and renal arteriography. Scan interpretations were expressed as a probability of a significant renal artery stenosis. Scan interpretations were compared with renal arteriographic results, renal vein renin levels, blood pressure values after renal artery repair, and blood pressure control after 4-26 months of clinical follow-up. Using > or = 50% luminal obstruction on arteriography as the reference standard for renal artery stenosis and a high probability scan representing a positive test, the test sensitivity and specificity were 33 and 97%, respectively (using high or indeterminate probability to represent a positive scan, the test sensitivity and specificity were 67 and 83%, respectively). The negative predictive value of a low probability scan for renal artery stenosis was 80%. However, including a measure of renovascular hypertension (blood pressure response to renal artery repair) as the reference standard, the accuracy of the scan improves, with the negative predictive value of a low probability scan for renovascular hypertension increasing to 97%. Scintigraphic results were also positively correlated with renal vein renin values in a statistically significant fashion (two-tailed Fisher exact test statistic = 6.43, P = 0.0219). Captopril-enhanced 99Tcm-MAG3 renal scintigraphy is a moderately accurate technique for detecting renal artery stenosis. More importantly, our preliminary findings suggest that the scintigraphic technique using 99Tcm-MAG3 appears to predict the blood pressure response to renal artery repair in subjects with suspected renovascular hypertension, thereby separating subjects with haemodynamically insignificant renal artery stenosis from those with renovascular hypertension.

Angiography↗

[Depression in the aged: preliminary evaluation of the effectiveness, as an screening instrument, of the 5-item version of the Geriatric Depression Scale].

INTRODUCTION: The best approach to improve under-recognition of depression is routine screening, ideally using an instrument that is highly effective and easy to administer. OBJECTIVE: To test the effectiveness of the 5-item version of the Geriatric Depression Scale (5-GDS) for depression screening in a community-dwelling Chilean elderly population. PARTICIPANTS AND METHODS: 110 subjects were evaluated at the geriatric outpatient clinic of a university teaching hospital. Patients answered a questionnaire that included the Geriatric Depression Scale (GDS), and demographic information. Using the 15-item GDS score as reference standard to classify subjects as depressed, test characteristics of the 5-GDS were evaluated. RESULTS: Subjects had a mean 15-item GDS score of 5.4; 47% classified as depressed. Depressed and not depressed subjects were similar with regard to demographics, educational level and comorbid conditions. The mean score was 1.9 for the 5-item GDS. Pearson correlation for 15-item and 5-item GDS scores was 0.92, p < 0.001. Using 15-item GDS score as reference standard, the 5-item GDS had a sensitivity of 0.88, specificity 0.90, positive predictive value 0.88 and negative predictive value 0.90. CONCLUSIONS: The 5-item GDS seems to be a promising screening tool for depression. If revalidated against clinical evaluation, it might be the preferred screening tool for depression in the Chilean community-dwelling elderly.

Aged↗

Characterization of serum-derived and recombinant rat IGF-I and their use for measuring true concentrations of IGF-I in rat plasma.

While numerous researchers have used rat models to investigate the in vivo actions of IGF-I, interpretation of the results in terms of true concentrations of rat IGF-I (rIGF-I) in plasma has been hampered by the absence of homologous reference standards. In order to overcome this we have produced recombinant rIGF-I (rrIGF-I) from Escherichia coli using procedures similar to those we have previously described for the production of other recombinant IGFs. The rrIGF-I is indistinguishable from serum-derived rIGF-I when characterized in a number of in vitro assays including ability to stimulate protein synthesis and inhibit protein degradation in cultured rat cells, as well as in interactions with the rat type-1 IGF receptor and with rat IGF-binding proteins. Moreover, both the serum-derived and the recombinant rat proteins are similar to recombinant human IGF-I (rhIGF-I) in these assays. However, differences between the human and rat IGFs are apparent when tested in immunoassays using some antibodies raised against rhIGF-I. Furthermore, the differences between rhIGF-I and rrIGF-I are even greater when rhIGF-I is used as the competing radiolabel in these assays, a situation that can lead to a two- to threefold underestimation of the actual concentration of IGF-I in rat plasma. These results indicate that, while immunoassays employing antibodies raised against rhIGF-I and rhIGF-I reference standards reliably indicate trends in IGF-I concentrations in rat plasma, the true amounts of rIGF-I present can only be assured in an assay using homologous tracer and reference peptides.

Animals↗

Renal volume measurements: accuracy and repeatability of US compared with that of MR imaging.

PURPOSE: To determine the accuracy and repeatability of ultrasonography (US) with the ellipsoid formula in calculating the renal volume. MATERIALS AND METHODS: The renal volumes in 20 volunteers aged 19-51 years were determined by using US with the ellipsoid formula and magnetic resonance (MR) imaging with the voxel-count method by two independent observers for each modality. The observers performed all measurements twice, with an interval between the first and second examinations. The voxel-count method was the reference standard. Repeatability was evaluated by calculating the SD of the difference (method of Bland and Altman). RESULTS: Renal volume was underestimated with US by 45 mL (25%) on average. A comparable underestimation was found when the ellipsoid formula was applied to MR images. This indicates that the inaccuracy of US renal volume measurements (a) occurred because the kidney does not resemble an ellipsoid and (b) was not primarily related to the imaging modality. Intra- and interobserver variations in US volume measurements were poor; the SD of the difference was 21-32 mL. For comparison, the SD of the difference in reference-standard measurements was 5-10 mL. CONCLUSION: Use of US with the ellipsoid formula is not appropriate for accurate and reproducible calculation of renal volume.

Adult↗

Non-small cell lung cancer: prospective comparison of integrated FDG PET/CT and CT alone for preoperative staging.

PURPOSE: To evaluate prospectively the accuracy of integrated positron emission tomography (PET) and computed tomography (CT) with use of fluorodeoxyglucose (FDG), compared with that of stand-alone CT, for the preoperative staging of non-small cell lung cancer, with surgical and histologic findings used as the reference standard. MATERIALS AND METHODS: Institutional review board approval and patient informed consent were obtained. From November 2003 to February 2004, 106 patients (78 men, 28 women; mean age, 56 years) with non-small cell lung cancer underwent curative surgical resection (tumor resection and lymph node dissection) after stand-alone CT followed by integrated FDG PET/CT. Tumor stages were determined by using the TNM and American Joint Committee on Cancer staging systems. Histopathologic results served as the reference standard. Statistically significant differences in tumor staging between integrated PET/CT and stand-alone CT were determined with P < .05 obtained by using the McNemar test or with a generalized estimating equation. RESULTS: The primary tumor was correctly staged in 84 patients (79%) at stand-alone CT and in 91 patients (86%) at integrated FDG PET/CT (P = .25). For the depiction of malignant nodes, the sensitivity, specificity, and accuracy of CT were 70% (23 of 33 nodal groups), 69% (248 of 360), and 69% (271 of 393), respectively, whereas those of PET/CT were 85% (28 of 33), 84% (302 of 360), and 84% (330 of 393) (P = .25, P < .001, and P < .001, respectively). There were 112 false-positive interpretations at CT for 54 hilar, 16 subcarinal, 29 paratracheal, 10 subaortic, and two pulmonary ligament nodal groups and one upper paratracheal group, compared with only 58 false-positive interpretations at PET/CT for 32 hilar, seven subcarinal, 13 lower paratracheal, and six subaortic nodal groups. There were 10 false-negative interpretations at CT for four hilar, two lower paratracheal, and two subcarinal nodal groups, one prevascular and retrotracheal group, and one inferior pulmonary group, but only five false-negative interpretations at PET/CT (one each for paratracheal, subaortic, subcarinal, inferior pulmonary, and hilar nodal groups). CONCLUSION: Integrated FDG PET/CT is significantly better than stand-alone CT for lung cancer staging and provides enhanced accuracy and specificity in nodal staging.

Carcinoma, Non-Small-Cell Lung↗

[Comments on the diagnostic criteria of mitral valve prolapse].

Two-dimensional echocardiography has been the reference standard for establishing the clinical diagnosis of mitral valve prolapse. Superior systolic displacement of the mitral leaflets, however, is not necessary abnormal. Whether and at what point leaflet displacement uniquely describes a pathologic process should not be accepted without defining the pattern of normal mitral leaflet motion. One should combine informations from phonocardiograms, Doppler color flow mapping and two-dimensional echocardiograms in an effort to avoid the artifice of using two-dimensional echocardiography as a categoric reference standard and to establish new clinical guidline or criteria that distinguish pathologic mitral valve prolapse from normal superior systolic displacement of the mitral leaflets. Mitral valve prolapse is a dynamic disease that results in varying clinical and morphologic presentations depending upon the degree of structural abnormality. Therefore, clinical and morphologic studies are required in not only severely symptomatic patients but also perfectly asymptomatic patients.

Echocardiography↗

Autorhythmometry: leads from single-sample medical check-ups toward a health science of time series.

Starting from the definition of health as given by the WHO, the authors emphasize that rhythms of biological variables should be taken into account if one is to arrive at a positive and individual definition of the concept of health. The evaluation of a single datum spot check of physiological functions does not permit to quantify health in dynamic terms whereas this may become possible when the rhythmic quality of these variables, according to a spectrum of characteristic frequencies, has been assessed. Rhythmometry provides for appropriate reference standards as regards both the population in general and the physical conditions of the same subject during certain spans in the (prospective) life history (spans selected according to consideration of risk and hence cost and benefit at a given age). The authors therefore stress the importance of rhythmometry, thanks to which the time course and other peculiarities of any biological phenomenon can be evaluated by obtaining serial measurements, objectively quantifying their characteristic features, and working out special models with the aid of computers. Of special interest, particularly for the evaluation of reference standards, is autorhythmometry (AR), to be used at least for certain variables. This is the method by which each subject studies himself, performing a certain number of measurements in the course of the day (or month or year) of his body temperature, blood pressure, cardiac rhythm, grip strength, etc. In AR, the subject takes an active part in the study of his condition of health and it has been shown that in the majority of cases these measurements are done with the utmost accuracy and precision, providing that the purpose of the operations to be performed has been adequately explained. The wide spread use of AR, during more or less extended periods in a lifetime, would permit the assessment of the normal situation for each individual and thus offer the possibility of diagnosing any disorder at its very beginning; it would thus be of great prophylactic value. The authors refer to the example of arterial blood pressure; widely different values for the normal levels can be found in the texts of different authors. They also show that a certain presure may be normal for a given subject at a certain time of day and be a sign of illness for another subject, or even for the same subject at a different ime. The authors suggest the introduction of AR in the curriculum of secondary schools and into the routine for outpatients and inpatients. This practice would increase the availability of information on public health at a lower cost. AR may be very usefully applied to chronotherapy: it is a well-known fact that there are rhythms of sensitivity and therefore rhythms of toxic as well as therapeutic effects for various drugs. These can be dove-tailed in such a way as to work out, for individual cases, a time for administration at which the therapeutic effect is at its maximum and the toxic one at its minimum...

Animals↗

Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference.

PURPOSE: To investigate in vitro the calcaneal trabecular bone structure in elderly human donors with high spatial resolution magnetic resonance (MR) imaging at 3.0 T and 1.5 T, to quantitatively compare MR measures of bone microarchitecture with those from micro-computed tomography (CT), and to compare the performance of 3.0-T MR imaging with that of 1.5-T MR imaging in differentiating donors with spinal fractures from those without spinal fractures. MATERIALS AND METHODS: The study was performed in line with institutional and legislative requirements; all donors had dedicated their body for educational and research purposes prior to death. Sagittal MR images of 49 human calcaneus cadaveric specimens were obtained (mean age of donors, 79.5 years +/- 11 [standard deviation]; 26 male donors, 23 female donors). After the spatial coregistering of images acquired at 3.0-T and 1.5-T MR imaging, the signal-to-noise-ratios and structural parameters obtained at each magnetic field strength were compared in corresponding sections. Micro-CT was performed on calcaneus cores obtained from corresponding regions in 40 cadaveric specimens. Vertebral deformities of the thoracic and lumbar spine were radiographically classified by using the spinal fracture index. Diagnostic performance of the structural parameters in differentiating donors with vertebral fractures from those without was assessed by using receiver operator characteristic (ROC) analysis, including area under the ROC curve (A(z)). RESULTS: Correlations between structural parameters at 3.0-T MR imaging and those at micro-CT were significantly higher (P < .05) than correlations between structural parameters at 1.5-T MR imaging and those at micro-CT (trabecular thickness, r = 0.76 at 3.0 T vs r = 0.57 at 1.5 T). Trabecular dimensions were amplified at 3.0 T because of increasing susceptibility artifacts. Also, higher ROC values were found for structural parameters at 3.0 T than at 1.5 T, but differences were not significant (trabecular thickness, A(z) = 0.75 at 3.0 T vs A(z) = 0.66 at 1.5 T, P > .05). CONCLUSION: MR imaging at 3.0 T provided a better measure of the trabecular bone structure than did MR imaging at 1.5 T. There was a trend for better differentiation of donors with from those without osteoporotic vertebral fractures at 3.0 T than at 1.5 T.

Aged↗

Transcranial Doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position.

BACKGROUND: Venous air embolism has been reported to occur in 23-45% of patients undergoing neurosurgical procedures in the sitting position. If venous air embolism occurs, a patent foramen ovale (PFO) is a risk factor for paradoxical air embolism and its sequelae. Preoperative screening for a PFO is therefore recommended by some investigators. The reference standard for identifying a PFO is contrast-enhanced transesophageal echocardiography (c-TEE). Contrast-enhanced transcranial Doppler ultrasonography (c-TCD) and contrast-enhanced transthoracic echocardiography (c-TTE) are noninvasive alternative methods, but so far there are no studies as to their diagnostic validity in neurosurgical patients. METHODS: The sensitivity and specificity of c-TCD and c-TTE in detecting a PFO were determined in a prospective study using c-TEE as the reference standard. Preoperative c-TCD, c-TTE, and c-TEE studies were performed during the Valsalva maneuver after intravenous echo-contrast medium (D-Galactose, Echovist-300, Schering AG, Berlin, Germany) was administered in 92 consecutive candidates (47 men and 45 women; mean age, 51 yr; range, 25-72 yr) before neurosurgical procedures in the sitting position. RESULTS: A PFO was detected in 24 of the 92 patients (26.0%) using c-TEE. c-TCD correctly identified 22 patients, whereas c-TTE only correctly identified 10. This corresponds to a sensitivity of 0.92 for c-TCD and 0.42 for c-TTE. The negative predictive value was 0.97 for c-TCD compared with 0.83 for c-TTE. The prevalence of a PFO in patients with a posterior fossa lesion was 27%, and in the group with cervical disc herniation was 24% as detected by c-TEE. The incidence of intraoperative venous air embolism was 35% in cases of cervical foraminotomy and 75% in posterior fossa surgery as detected by c-TEE. CONCLUSIONS: c-TCD is a highly sensitive and highly specific method for detecting a PFO. Because c-TCD is noninvasive, it may be more suitable than c-TEE for routine preoperative screening for a PFO. C-TTE is not reliable in detecting a PFO.

Adult↗

Minimally invasive nephron-sparing surgery (MINSS) for renal tumours. Part II: probe ablative therapy.

OBJECTIVES: To review the evolution and current status of probe ablative methods of minimally invasive nephron-sparing surgery (MINSS) for renal tumours. METHODS: The English language literature of the past 10 yr was reviewed by using the National Library of Medicine database and the following keywords: chemoablation, cryoablation, high-intensity focused ultrasound, kidney, laser interstitial thermotherapy, microwave thermotherapy, nephron-sparing surgery, radiofrequency ablation, radiosurgery, renal, and tumour. Over 300 papers were identified, 50 of which were selected for this review on the basis of their contribution in advancing the field with regards to (1) evolution of concepts, (2) development and refinement of techniques, and (3) intermediate- and long-term clinical outcomes. RESULTS: Open partial nephrectomy is the reference standard for nephron-sparing surgery against which all MINSS techniques should be measured. Although the initial outcomes of cryoablation and radiofrequency ablation (RFA) are encouraging, long-term studies are necessary to confirm lasting efficacy. The optimal modality for tumour targeting, monitoring therapy, and follow-up remains to be determined. These ablative techniques should be reserved for carefully selected patients, the data should be prospectively accrued, and the long-term cancer cure rates should be compared with the reference standard. CONCLUSIONS: Promising long-term data are available for cryoablation. RFA is still considered developmental, and instances of incomplete cell kill, despite nonenhancement, are concerning. Other modalities are still experimental.

Catheter Ablation↗

Differential expression of proteases in human gestational tissues before, during and after spontaneous-onset labour at term.

A number of tightly regulated proteolytic enzyme systems, including the plasminogen activation cascade and matrix metalloproteases, play integral roles in the remodelling of extracellular matrices during pregnancy and parturition. This study assessed these labour-associated changes in protease activity in human gestational tissues. Amnion, choriodecidua and placenta collected from women before (at caesarean section, not in labour), during (at caesarean section, in labour) and after (spontaneous-onset labour, normal vaginal delivery) labour were examined on gelatin-substrate SDS-PAGE zymography. All tissues displayed major 55 kDa plasminogen-dependent activity that was abolished by the serine protease inhibitors (10 mmol phenylmethyl-sulphonylfluoride l-1, 100 mmol epsilon aminocaproic acid l-1, 1 mmol Glu-Gly-Arg chloromethylketone l-1). The enzymic activity was identified as urokinase plasminogen activator on the basis of its co-migration with reference standard and western blot analysis, and did not vary with labour status. An additional protease with an apparent molecular mass of approximately 90 kDa was detected in all tissues. Densitometric measurement of these tissues showed a significant (P < 0.05) increase in this enzyme activity with labour onset. Heavy metal chelators (1 mmol 1.10 phenanthroline l-1 and 10 mmol EDTA l-1) selectively blocked the 90 kDa activity, consistent with the proposal that it is a metalloprotease. Co-migration with reference standard and western blot analysis confirmed the identity of this protease as the matrix metalloprotease 9 (MMP-9). Immunoreactive MMP-9 protein was also significantly (P < 0.05) increased during and after labour compared with before labour in all tissues examined. It is proposed that the upregulated expression of MMP-9 is involved in fetal membrane rupture and placental separation during and after labour onset, respectively. In conclusion, the regulated repertoire of protease activities expressed by human gestational tissues implies an important role for matrix-degrading enzymes during human parturition.

Amnion↗

Symmetry of nerve conduction studies in different stages of diabetic polyneuropathy.

Nerve conduction studies (NCS) in diabetic sensorimotor polyneuropathy (DSP) are sensitive, noninvasive, and associated with small coefficients of variation, and correlate well with underlying peripheral nerve morphological change. For these reasons, the current reference standard for DSP involves multivariate instruments that emphasize NCS results. However, the interside symmetry of NCS findings in different stages of DSP are unknown, although requirement for symmetry has been suggested in clinical trials of DSP. We therefore aimed to determine the degree of symmetry of NCS findings in DSP of differing severity stages. A cohort of diabetic patients, including patients without neuropathy and those with mild to severe DSP, was studied. We also studied a series of nondiabetic, healthy subjects. A variation of stratified sampling by means of a clinical neuropathy score ensured that a broad spectrum of neuropathy was studied. A total of 478 subjects was ascertained; patient accrual was discontinued when the smallest clinical group consisted of 50 subjects. Nerve conduction studies were conducted prospectively and in a blinded fashion using surface recordings, averaging for sensory action potentials, control of limb temperature, and standardized techniques. Median and ulnar motor and sensory, peroneal and tibial motor, and sural NCS were performed. Interside symmetry, independent of neuropathy severity, was observed for all investigated nerves, except for the median sensory nerve action potential amplitude, which was lower on the right side. These results confirm that abnormal NCS findings consistent with DSP are reliably symmetrical with the exception of the amplitude of the median sensory nerve action potential. Thus, unilateral evaluation of NCS in DSP is sufficient as a reference standard in clinical trials. We also conclude that great degrees of asymmetry in NCS results are reason to question inclusion of DSP patients in clinical trials.

Adult↗

Diagnosis of lumbar spinal stenosis in adults: a metaanalysis of the accuracy of CT, MR, and myelography.

We undertook a literature synthesis of CT, MR, and myelographic studies to evaluate what is known about the diagnostic accuracy of these imaging tests for the diagnosis of lumbar spinal stenosis in adults without prior surgery. From 116 possibly relevant studies, we reviewed 14 articles that included cases of spinal stenosis with a reference standard other than the imaging tests of interest. Of the studies we reviewed, two involved only MR, nine only CT, and three used both; six studies included myelography. Rating categories of A, B, C, or D were assigned for the quality of research methods used to estimate diagnostic accuracy. All studies received either a C or D rating. Common methodologic problems were failure to assemble a representative cohort for study, small sample size, and failure to maintain independence between image readings and reference standards. Sensitivity ranged from 0.81 to 0.97 for MR, from 0.70 to 1.0 for CT, and from 0.67 to 0.78 myelography. Studies varied greatly in case selection, definition of test and disease categories, and geographic locale, so no pooled estimates could be derived. In asymptomatic patients, abnormal findings appeared on CT or MR in 4-28% of cases and were more common in the elderly. Published studies of the value of CT and MR for the diagnosis of lumbar stenosis lack methodologic rigor and do not permit strong conclusions about the relative diagnostic accuracies of these procedures. For the present, the choice between MR or CT depends on issues such as costs, reimbursements, access to equipment, skill of radiologists, and patient safety. Better studies will be needed to document claims for improvements in imaging accuracy as MR technologies evolve. These studies should emphasize larger sample sizes, more attention to research designs that avoid methodologic biases, and the contribution of imaging diagnoses to ultimate clinical outcome.

Evaluation Studies as Topic↗

Reproducibility of the STARD checklist: an instrument to assess the quality of reporting of diagnostic accuracy studies.

BACKGROUND: In January 2003, STAndards for the Reporting of Diagnostic accuracy studies (STARD) were published in a number of journals, to improve the quality of reporting in diagnostic accuracy studies. We designed a study to investigate the inter-assessment reproducibility, and intra- and inter-observer reproducibility of the items in the STARD statement. METHODS: Thirty-two diagnostic accuracy studies published in 2000 in medical journals with an impact factor of at least 4 were included. Two reviewers independently evaluated the quality of reporting of these studies using the 25 items of the STARD statement. A consensus evaluation was obtained by discussing and resolving disagreements between reviewers. Almost two years later, the same studies were evaluated by the same reviewers. For each item, percentages agreement and Cohen's kappa between first and second consensus assessments (inter-assessment) were calculated. Intraclass Correlation coefficients (ICC) were calculated to evaluate its reliability. RESULTS: The overall inter-assessment agreement for all items of the STARD statement was 85% (Cohen's kappa 0.70) and varied from 63% to 100% for individual items. The largest differences between the two assessments were found for the reporting of the rationale of the reference standard (kappa 0.37), number of included participants that underwent tests (kappa 0.28), distribution of the severity of the disease (kappa 0.23), a cross tabulation of the results of the index test by the results of the reference standard (kappa 0.33) and how indeterminate results, missing data and outliers were handled (kappa 0.25). Within and between reviewers, also large differences were observed for these items. The inter-assessment reliability of the STARD checklist was satisfactory (ICC = 0.79 [95% CI: 0.62 to 0.89]). CONCLUSION: Although the overall reproducibility of the quality of reporting on diagnostic accuracy studies using the STARD statement was found to be good, substantial disagreements were found for specific items. These disagreements were not so much caused by differences in interpretation of the items by the reviewers but rather by difficulties in assessing the reporting of these items due to lack of clarity within the articles. Including a flow diagram in all reports on diagnostic accuracy studies would be very helpful in reducing confusion between readers and among reviewers.

Advisory Committees↗

Variation in the diagnostic performance of D-dimer for suspected deep vein thrombosis.

BACKGROUND: Numerous studies have evaluated the accuracy of D-dimer in diagnosing suspected deep vein thrombosis (DVT), but results are conflicting. AIM: To overview estimates of the diagnostic accuracy of D-dimer and identify causes of variation. DESIGN: Systematic review, meta-analysis and meta-regression. METHODS: We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, citation lists, and contacted manufacturers. We selected studies that compared D-dimer to a reference standard in patients with suspected DVT. Data were analysed by random effects meta-analysis and meta-regression. RESULTS: We included 97 studies reporting 198 assays in 99 different patient groups. Overall estimated sensitivity and specificity of D-dimer were 90.5% and 54.7%, but both estimates were subject to significant heterogeneity (p < 0.001). Meta-regression identified that some heterogeneity was explained by study setting, exclusion criteria, whether recruitment was consecutive or the study prospective, whether D-dimer and the reference standard were measured blind, and whether the D-dimer threshold was determined a priori. Sensitivity and specificity also varied between ELISA (94% and 45% respectively), latex (89% and 55%) and whole blood agglutination assays (87% and 68%). Sensitivity was higher for proximal than distal DVT. Specificity was dependent upon whether clinical probability of DVT was high (specificity 51%), intermediate (67%) or low (78%). DISCUSSION: D-dimer has good sensitivity, but poor specificity, for DVT. Estimates are subject to substantial heterogeneity from various sources. D-dimer specificity appears to be strongly dependent upon the pre-test clinical probability of DVT.

Antifibrinolytic Agents↗