Design of a new pulsatile bioreactor for tissue engineered aortic heart valve formation.

Evidence has been gathered that biomechanical factors have a significant impact on cell differentiation and behavior in in vitro cell cultures. The aim of this bioreactor is to create a physiological environment in which tissue engineered (TE) aortic valves seeded with human cells can be cultivated during a period of several days. The bioreactor consists of 2 major parts: the left ventricle (LV) and the afterload consisting of a compliance, representing the elastic function of the large arteries, and in series a resistance, mimicking the arterioles and capillaries. The TE aortic valve is placed between the LV and the compliance. With controllable resistance, compliance, stroke volume and frequency, and hydrodynamic conditions can be changed over a wide physiological range. This study resulted in a prototype of a compact pulsatile flow system for the creation of TE aortic valves. In addition a biocompatibility study of the used materials is performed.

Aortic Valve↗

Elimination of residual blood flow-related signal in 3D volume-selective TSE arterial wall imaging using velocity-sensitive phase reconstruction.

PURPOSE: To improve 3D volume-selective turbo spin-echo (TSE) arterial wall imaging by introducing velocity phase sensitivity to the sequence. MATERIALS AND METHODS: Slow or recirculating blood may give incomplete nulling in 3D vessel wall imaging, hindering differentiation between arterial wall and lumen. Reconstructed phase images are used to reduce the residual blood signal with postprocessing. A volume-selective 3D TSE (1) sequence with increased velocity sensitivity perpendicular to the slab was developed. Sensitivity was introduced by modifying the gradient waveforms such that residual signal from slow or recirculating blood is distinguished from the wall by the phase shift introduced. This was tested on a pulsatile flow phantom and the carotid artery wall of six healthy volunteers and 17 patients. Images were acquired on a Siemens Magnetom Sonata 1.5T scanner. A quantitative comparison of the lumen/wall contrast was made using images acquired with and without modification. RESULTS: Velocity sensitivity produces significantly reduced residual signal by intravoxel dephasing. Phantom "lumen/tissue" contrast improved by 0.10 (P < 0.01), with a similar change in vivo (0.69-0.73, P < 0.01). Postprocessing removal of the blood signal using phase signal provided further improvement. CONCLUSION: Introducing velocity sensitivity reduces unwanted, potentially misleading residual blood in 3D volume-selective vessel wall imaging.

Adult↗

Evaluation of a transparent blood analog fluid: aqueous xanthan gum/glycerin.

Aqueous solutions of Xanthan gum and glycerin were developed that match both the viscous and elastic components of the 2 Hz complex viscosity of blood over a broad range of shear rates (1-1000 s-1) and hematocrits (20%-80%). Measurements of wall shear rate in pulsatile flow were conducted in straight and atherogenic curved artery models using both the blood analog fluid and blood to compare their flow behavior. Peak wall shear rates determined in these models under nearly identical flow conditions with the two fluids were not statistically different (p > 0.05). These results indicate that aqueous Xanthan gum/glycerin solutions provide a good blood analog fluid for flow conditions characteristic of large arteries. Because the fluid is transparent and made from readily available and fairly inexpensive materials, it may be generally useful for in vitro hemodynamic studies, particularly those employing optical techniques.

Animals↗

Influence of geometric and hemodynamic parameters on aneurysm visualization during three-dimensional rotational angiography: an in vitro study.

BACKGROUND AND PURPOSE: Aneurysm depiction with three-dimensional (3D) rotational angiography is influenced by investigator-defined parameters such as image acquisition and contrast agent injection and by the hemodynamic pattern in the parent artery and aneurysm. To assess the impact of the geometric configuration of parent artery and aneurysm on the 3D visualization of saccular aneurysms, we studied silicone aneurysm models under pulsatile-flow conditions. METHODS: Rotational angiography was performed in three bifurcation and three lateral aneurysm models with ostia of different widths. Three acquisition modalities (5, 8, and 14 seconds in duration, acquisition rate of 10 frames per second) and two techniques for the injection of contrast material (continuous flow and injection with an initial bolus) were applied. 3D reconstructions were obtained with a volume-rendering technique. RESULTS: Bifurcation aneurysms were visualized with high accuracy. Filling deficits distant to the inflow zone could be compensated for with the bolus-injection technique, and complete depiction of aneurysm shape was achieved in the 8-second rotation with 20 mL of contrast agent. In lateral aneurysms, the accuracy of 3D reconstructions depended on the width of the ostium. Although rotational studies in wide-necked lateral aneurysms yielded adequate reconstructions, 3D visualization of small-necked aneurysms was incomplete with the preferential depiction of the distal shell, which represents the inflow zone into the aneurysmal lumen. CONCLUSION: Contrast agent injection with the initial-bolus technique improved the depiction of aneurysms, compared with the continuous-flow method. Reconstructions of rotational studies of narrow-necked lateral aneurysms yielded incomplete visualization of the aneurysm.

Cerebral Angiography↗

Comparative study of the hydrodynamic function of six size 19 mm bileaflet heart valves.

The hydrodynamic function of six size 19 mm bileaflet mechanical heart valves was investigated in a pulsatile flow simulator. The St. Jude Standard, St. Jude Haemodynamic Plus, CarboMedics, Sorin Biomedica, Duromedics and ATS valves were studied. The mean pressure drop and effective orifice area during forward flow, regurgitant volumes and total energy loss were analysed. The St Jude Haemodynamic Plus and Sorin Biomedica valves had significantly lower forward flow pressure drops and total energy losses than the other four valves. Assuming that all six valves can be implanted in the equivalent size of aortic root, this should lead to improved in vivo performance.

Aortic Valve↗

The realization of a pulsatile implantable impeller pump with low hemolysis.

A pulsatile implantable impeller pump with low hemolysis was developed without markedly increasing the complexity of the system compared with the nonpulsatile pump. The key to the question is to design a three-dimensional impeller with twisted vanes, compacted by an axial helical spiral and a radial logarithmic spiral so as to reduce the turbulent shear in the pump as the impeller changes its rotations per minute periodically to generate a physiologic pulsatile flow. Both mathematic computation of velocity distribution in the impeller and geometric illustration of the velocity triangle at the top of the vane have demonstrated that the peripheral velocity variation of blood cells in a twisted impeller will be less than that in an untwisted impeller. Thus, the main mechanical factor of hemolysis in the impeller pump, namely, the turbulent shear, should be reduced because it is proportional to the product of velocity variations measured in two perpendicular directions. In the in vitro experiments, the pump delivered 4 L/min mean flow at 100 mm Hg mean pressure (pulsed between 80-120 mm Hg) for more than 3 h in a circulatory model containing 700 ml of fresh citrated porcine blood. Every half hour, the free hemoglobin level in the plasma was tested, and the resulting index of hemolysis was about 0.020, slightly more than that of a nonpulsatile impeller pump developed in Shanghai. To compare hemolysis, the index of hemolysis of this pump is about 1/6 of that of the self-made diaphragm pump and 1/13 of that of the Polystan Pulsatile Pump.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Development of an affordable diaphragmatic pump for cardiopulmonary bypass: an in vivo evaluation.

A new diaphragmatic pump (L-Y pump) and its drive unit were developed in our institute. The pump has a priming volume of 80 ml. The pump housing is 72 mm in diameter and 42 mm in height. Its total weight is 139 g. To assess and confirm the function and controllability of this pump, comparative studies of cardiopulmonary bypass (CPB) with L-Y pump (group A) and conventional roller pump (Group B) were performed using dogs. Both pumps provided pump flow of 90 to 100 ml/kg/min. The hemodynamics of both groups were stable and within the normal range. No leakage or thrombus formation was observed in the L-Y pump. All biochemistry data showed no significant differences between the 2 groups. This data demonstrated low plasma-free hemoglobin levels in the L-Y pump group; after 120 min of CPB, mean plasma free hemoglobin levels were 48.7 +/- 8.6 mg/dl in the roller pump group and 21.4 +/- 7.1 mg/dl in the L-Y pump group, and minimal hemolysis was indicated. In conclusion, this L-Y pump and its controller system might be useful for CPB in terms of its low hemolysis and good pump quality. This pump demonstrated easy manipulation, good controllability, and provided a sufficient pulsatile flow. This pump is suitable not only for CPB, but also as a long-term circulatory support system.

Animals↗

Development of the Marseilles pulsatile rotary blood pump for permanent implantable left ventricular assistance.

We have developed a low-speed, double-lobed hypocycloidal pump that furnishes a pulsatile flow without valves. The pump is coupled to a specially designed electric motor. The motor/pump unit is totally implantable and has been extensively tested in vitro and in vivo in animals. Because this pump is volumetric, it is necessary to control speed precisely to avoid overpumping. Our control system, which is based on analysis of the motor current wave form, can detect and prevent negative pressures before they occur. The physical properties and hemocompatibility of several construction materials have been studied to determine their suitability for clinical use. These materials include a graphite substrate, titanium nitrate surface coating, boric carbon, and amorphous diamond. The pumps currently being tested are made of titanium, but clinical versions will be made of composite materials selected from this preliminary study. In vivo testing of this pump confirmed its good hemodynamic performance, low hemolysis rate, and biocompatibility (i.e., low heat, noise, and vibration levels). Animal experiments were terminated after 15 days because of mechanical failure related to the accumulation of blood components on moving parts. A new pump in which the mechanism is completely sealed from the blood flow has been designed and will soon be tested. If this sealed design is effective, the pump should be ready for use as a permanent implantable ventricular assistance device.

Animals↗

Hepatic venous blood and the development of pulmonary arteriovenous malformations in congenital heart disease.

BACKGROUND: Pulmonary arteriovenous malformations (PAVMs) are a known complication after some types of cavopulmonary anastomoses (CVPAs). Their cause is unknown, but they may be related to the absence of pulsatile flow or the presence or absence of circulating factors. These PAVMs are diffuse and are presumed to be progressive and irreversible. METHODS AND RESULTS: All patients with congenital heart disease (CHD) seen at Children's Hospital, Boston, Mass, between 1970 and 1993 were reviewed. We report on the 10 patients with CHD who were found to have developed PAVMs, as diagnosed by cardiac catheterization. Diagnoses included heterotaxy syndrome/polysplenia, with interrupted inferior vena cava and hepatic veins draining to the right atrium (n = 6); heterotaxy/asplenia (n = 1); corrected transposition with pulmonary stenosis (n = 1); and biliary atresia and associated CHD (n = 2). PAVMs were diagnosed 0.1 to 7.0 years (median, 3.5 years) after creation of a CVPA that resulted in exclusion of hepatic venous flow from one or both lungs in 8 of the 10 patients; the remaining 2 patients had normal drainage of hepatic veins to the lungs but had biliary atresia. In all, the common anatomic feature was the exclusion of normal hepatic venous return from the affected pulmonary arterial circulation. All patients with interrupted inferior vena cava, azygous continuation to the superior vena cava, and hepatic veins draining to the right atrium (polysplenia syndrome) were reviewed to determine the incidence of PAVMs in those with CVPA (ie, hepatic venous flow excluded from the pulmonary arteries) and without CVPA. Six of 28 (21%) of those with versus 1 of 56 (1.8%) of those without CVPA developed PAVMs (P = .004). The 1 patient without CVPA who had PAVMs also had biliary atresia. Among patients with CVPA, the probability of developing PAVMs was 15% and 28% at 3 and 5 years, respectively, after CVPA. The histological and angiographic appearances of PAVMs after CVPA are similar to those seen in PAVMs associated with hepatic cirrhosis. CONCLUSIONS: We postulate that PAVMs after CVPA are related to the diversion of normal hepatic venous flow from the pulmonary circulation. In this sense, these PAVMs may be analogous to those associated with liver disease, which have been found to resolve after liver transplantation. Redirection of hepatic flow to the pulmonary bed in some patients with CHD and PAVMs may lead to reversibility of the PAVMs.

Adult↗

Blood flow velocity and pulsatility index differences in patients with unilateral migraine.

OBJECTIVE: To evaluate blood flow velocity and pulsatility in unilateral migraine without aura during the headache-free period using transcranial Doppler (TCD) sonography. METHODS: Patients with unilateral headache were recruited during the headache-free period. Maximum mean flow velocity (MFV) and pulsatility index (PI) were measured in the middle cerebral (MCA) and basilar arteries. Controls were headache-free individuals without cerebrovascular disease. RESULTS: Twenty-five patients with right-sided migraine, 25 patients with left-sided migraine, and 19 controls were studied. The MCA PI was higher on the right headache side versus the left headache side (0.97 +/- 0.2 versus 0.86 +/- 0.1 cm/s, P =.02) and versus controls (0.9 +/- 0.2 cm/s, NS). The basilar artery MFV was higher in patients with right-sided headache versus left-sided headache (39.5 +/- 5.6 versus 34.7 +/- 8.2 cm/s, P =.02) and versus controls (38.2 +/- 8 cm/s, NS). No decrease in MFV with age was observed in patients with migraine. CONCLUSIONS: Middle cerebral artery flow pulsatility and basilar artery velocity are higher in patients with right-sided migraine compared with left-sided migraineurs, during the headache-free period. Although these parameters were similar to controls, the differences found during the headache-free period in migraineurs may indicate vascular involvement predisposing to the unilateral headache recurrence.

Adult↗

Mammalian cardiovascular morphology and the maintenance of cerebral function at high Gz.

The persistence of consciousness at low cerebral perfusion pressures during exposure to high sustained G force in a head-to-foot direction (+Gz), is the rule. Concomitant changes in cerebrospinal fluid and cerebral venous dynamics together with cerebral autoregulation have been proposed to explain this preservation of cerebral function at high Gz. The non-uniform distensibility of the mammalian aortic distributing system plays a fundamental role in maintaining optimal cardiac energy exchange. Morphological evidence is presented suggesting that such a non-uniformity probably extends cranially as well as caudally in man. One consequence of such a cranial extension would be the amplification of the arterial pressure waves to the brain, with the potential for significant pulsatile flow at relatively low mean arterial blood pressures. Such phenomena would result from fundamental design properties of the mammalian cardiovascular system, would not be detected by conventional invasive pressure monitoring, and would serve as a mechanism to maintain optimal cerebral perfusion under condition of increasing +Gz.

Animals↗

CSF flow measurement in syringomyelia.

BACKGROUND AND PURPOSE: CSF circulation has been reported to represent a major factor in the pathophysiology of syringomyelia. Our purpose was to determine the CSF flow patterns in spinal cord cysts and in the subararachnoid space in patients with syringomyelia associated with Chiari I malformation and to evaluate the modifications of the flow resulting from surgery. METHODS: Eighteen patients with syringomyelia were examined with a 3D Fourier encoding velocity imaging technique. A prospectively gated 2D axial sequence with velocity encoding in the craniocaudal direction in the cervical region was set at a velocity of +/- 10 cm/s. Velocity measurements were performed in the larger portion of the cysts and, at the same cervical level, in the pericystic subarachnoid spaces. All patients underwent a surgical procedure involving dural opening followed by duroplasty. Pre- and postoperative velocity measurements of all patients were taken, with a mean follow-up of 10.2 months. We compared the velocity measurements with the morphology of the cysts and with the clinical data. Spinal subarachnoid spaces of 19 healthy subjects were also studied using the same technique. RESULTS: A pulsatile flow was observed in syrinx cavities and in the pericystic subarachnoid spaces (PCSS). Preoperative maximum systolic cyst velocities were higher than were diastolic velocities. A systolic velocity peak was well defined in all cases, first in the cyst and then in the PCSS. Higher systolic and diastolic cyst velocities are observed in large cysts and in patients with a poor clinical status. After surgery, a decrease in cyst volume (evaluated on the basis of the extension of the cyst and the compression of the PCSS) was observed in 13 patients. In the postoperative course, we noticed a decrease of systolic and diastolic cyst velocities and a parallel increase of systolic PCSS velocities. Diastolic cyst velocities correlated with the preoperative clinical status of the patients and, after surgery, in patients with a satisfactory foraminal enlargement evaluated on the basis of the visibility of the cisterna magna. CONCLUSION: CSF flow measurement constitutes a direct evaluation for the follow-up of patients with syringomyelic cysts. Diastolic and systolic cyst velocities can assist in the evaluation of the efficacy of surgery.

Adult↗

Axial reciprocation of rotating impeller: a novel approach to preventing thrombosis in centrifugal pump.

For long-term application, rotary pumps have to solve the problems of bearing wear and thrombosis along the bearing. Some investigators choose the magnetic bearing for zero friction and to provide no contact between the rotor and stator; the former avoids the mechanical wear and the latter eliminates the possibility of thrombus formation. The authors have tried and have found, however, that it is difficult to apply a magnetic bearing to the rotary pump without disturbing its simplicity, reliability, and implantability, and have therefore developed a much simpler approach to achieve the same results. Instead of using a sliding bearing, a rolling bearing has been devised, and its friction is about 1/15 that of the sliding bearing. Furthermore, a wearproof material of ultra high molecular weight polythene has been adopted to make the rollers, and its antiwear property is eight times better than metal. The service life of the bearing has thus been prolonged. To prevent thrombus formation along the bearing, the impeller reciprocates axially as the impeller changes its rotating speed periodically to produce a pulsatile flow. The reciprocation is the result of the effects of a magnetic force between the motor rotor and stator and a hydraulic force between the blood flow and the impeller. Similar to a piston pump, the oscillating impeller can make the blood flow in and out of the bearing, resulting in washout with fresh blood once a cycle. This obviously helps to prevent thrombosis along the bearing and in the pump. Endurance tests with saline of this novel pump demonstrated device durability, promising long-term assisted circulation.

Centrifugation↗

Doppler ultrasonographic diagnosis and anatomy of congenital intrahepatic arterioportal fistula in a puppy.

A dilated, tortuous blood vessel was identified sonographically in the right medial liver lobe in a puppy with severe ascites. This vessel was thought to represent the dilated right medial portal vein branch. Using pulsed wave Doppler ultrasonography, retrograde, abnormally pulsatile flow was detected in both the dilated right medial portal vein branch and the main portal vein. The right medial liver lobe was surgically resected then fixed in formalin. Silicon rubber was injected and outlined the connection between the portal vein and hepatic artery.

Animals↗

An in-vitro technique for assessment of thrombogenicity in mechanical prosthetic cardiac valves: evaluation with a range of valve types.

BACKGROUND AND AIM OF THE STUDY: An in-vitro technique has been developed to assess the flow-induced thrombosis of artificial heart valves, using renneted milk as a blood analog. Previous studies have demonstrated similarities between the clotting of blood and milk on both microscopic and macroscopic scales. The study aim was to further validate the milk test by comparing the locations of milk clot to those of thrombus formation on a wide selection of mechanical heart valves. METHODS: Nine different valves were tested in the aortic position of a model heart chamber in the Edinburgh milk rig. These included caged-ball valves (Starr-Edwards silastic ball with bare struts and metal ball with cloth-covered struts), tilting-disc valves (Björk-Shiley Standard, Björk-Shiley Monostrut, Medtronic-Hall, and Ultracor), and bileaflet valves (St. Jude Medical, Edwards-Duromedics, and CarboMedics). Renneted milk was pumped through the valves for 30 min at 2 l/min, 70 bpm pulsatile flow. After each run, valves were photographed for comparison with documented sites of thrombosis. RESULTS: All valves developed milk clot in specific, reproducible locations when run in the aortic position. Milk clot was found on the struts of caged-ball valves and tilting-disc valves, and around the hinge mechanism of the bileaflet valves. This compared favorably to documented cases of thrombosis in vivo. CONCLUSION: Renneted milk may be used to model flow-induced thrombus formation and to predict the thrombogenic sites of mechanical heart valves. Whilst it is not suggested that milk mimics the entire blood coagulation cascade, these results indicate that such behavior may not be necessary for predicting fluid mechanically induced clotting.

Animals↗

Factors affecting pulsatile ocular blood flow in normal subjects.

BACKGROUND: The factors that influence pulsatile ocular blood flow (POBF) were evaluated in normal subjects. METHODS: POBF was measured in 80 normal subjects using Langham OBF computerised tonometry. The effect of age, systolic and diastolic blood pressure, refractive error, intraocular pressure, and axial length on POBF was evaluated using multiple regression analysis. RESULTS: The mean (SD) POBF value was 593.3 (203.6) microl/min (range 290.7-1201.6). Of all the independent variables in the model, only the axial length was statistically significant (p = 0.008). The regression coefficient was negative, indicating that the axial length decreased with increasing POBF. CONCLUSIONS: These data suggest that, in normal subjects, the POBF decreases as axial length increases. Choroidal blood flow may decrease as the axial length increases. The axial length may therefore be a major factor affecting POBF.

Adult↗

Contractile responses in arteries subjected to hypertensive pressure in seven-day organ culture.

Early stage changes in hypertensive arteries have a significant effect on the long-term adaptation of the arteries. Compared to the long-term adaptation, little is known about the early dimensional and functional changes in hypertensive arteries in the first few days of hypertension. To study the early stage changes in hypertensive arteries, porcine common carotid arteries were cultured for seven days in a simplified ex vivo artery organ culture system with pulsatile flow under hypertensive (200+/-30 mm Hg) or normotensive (100+/-20 mm Hg) pressure conditions while maintaining a physiological mean wall shear stress of 15 dyn/cm2. Vessel viability was demonstrated by contractile diameter responses to norepinephrine (NE), carbachol (CCh), and sodium nitroprusside (SNP) as well as staining for mitochondrial activity and cell apoptosis/necrosis. The results show that arteries demonstrated strong contractile responses to NE, CCh, and SNP, basal tone, and viable mitochondria in the organ culture system for seven days. Hypertensive arteries demonstrated a stronger contractile response than normotensive arteries (p<0.05). Diameter enlargement was observed in hypertensive arteries as compared to arteries cultured under normotensive conditions. In conclusion, the pulsatile culture system can maintain arteries viable with active vasomotion tone for up to seven days. Hypertensive pressure causes arterial adaptation by significantly increasing arterial diameter and contractile response within the first seven days.

Adaptation, Physiological↗

A model for the design and evaluation of algorithms for closed-loop cardiovascular therapy.

Developing a clinically useful closed-loop drug delivery system can be extremely time consuming and costly. One approach to reducing the time and cost associated with developing closed-loop systems is to reduce the number of animal experiments and perform an extensive set of simulation studies. Through simulations, a closed-loop controller's performance can be evaluated over a complete spectrum of the patient population, including boundary conditions. Simulation studies are repeatable, offering significant advantages in comparing modifications in control algorithms. Finally, simulation studies can be performed in a fraction of the time required for animal studies, at a fraction of the cost. We have developed a simulator, that included a nonlinear pulsatile-flow cardiovascular model, a physiological regulatory mechanism, and the pharmacology of four frequently titrated cardiovascular drugs. This simulator has already been used in the design and evaluation of two closed-loop algorithms-a self-tuning regulator (STR) and a multiple model adaptive controller (MMAC)-for blood pressure control during and after cardiac surgery.

Algorithms↗