Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Coloring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68Linked to original sources

[Three-dimensional transesophageal echocardiographic assessment for prosthetic valves].

We evaluated three-dimensional transesophageal echocardiographic assessment of the implanted mechanical valves by rotational scanning method. Patients were 7 mitral valve replacement and one aortic valve replacement, 2 mitral and aortic valve replacement. In 2 cases of 7 mitral valve replacement, the prosthetic valve regurgitation was evaluated using by color Doppler echocardiography. In this study, multiplane transesophageal probe was used. It rotated at 2-degree intervals from 0 to 180 degrees and the three-dimensional reconstruction was performed by echo scan workstation system (TOMTEC Inc, Munich, Germany). In mitral valve replacement cases, the valve motion of bileaflet valve (St. Jude Medical valve and ATS valve) were showed very clearly. The struts was easily recognized in the St. Jude Medical valve (SJM valve) cases. In one of SJM valve cases, the pannus formation was revealed, but it did not disturb valve motion. The prosthetic valve regurgitation can be seen accurately. However, aortic valve and ball valve cases cannot be reconstructed because of artifact from prosthetic valve and ultrasonic direction. The prosthetic valve regurgitation, pannus formation which was difficult to be showed in two-dimensional echocardiography and relationship between annulus and sewing cuff can be evaluated by this three-dimensional echocardiography. In this study, this system has some problems, for example real-time evaluation is impossible, aortic valve and ball valve cases cannot be reconstructed. However, we think that this new technology is suitable for evaluating valve thrombus, valve dysfunction and paravalvular leakage. In conclusion, the three-dimensional echo-cardiography demonstrated, reliable and accurate examination, and it can evaluate various complications of prosthetic valve.

Adult↗

Angiography of leaks after endovascular repair of infrarenal aortic aneurysms.

OBJECTIVE: We examined whether leaks that persist after stent grafting are associated with outflow arteries. SUBJECTS AND METHODS: Selective angiography was performed in 21 patients with persistent leaks after undergoing endovascular repair of infrarenal aneurysms of the abdominal aorta. Late leaks occurred in five patients whose prostheses were originally sealed. Before angiography, the size and position of leaks were determined with CT and color Doppler sonography. RESULTS: Superselective angiography was successful in 19 of 21 patients. In two patients, angiography was performed over the afferent artery supplying the leak. We found one outflow artery at the site of the leak in 10 patients (47%); two outflow arteries in five (23.8%); and as many as five outflow arteries in three (14%). Angiography overlooked outflow arteries in three patients (14%). The lumbar and inferior mesenteric, urethral, and testicular arteries were identified as outflow arteries. CONCLUSION: Other than feeder arteries, persistent leaks are associated with outflow vessels that contribute to the patency of leaks.

Adult↗

[Case of occlusal reconstruction for severe attrition].

PATIENT: A 57-year-old female complained of aesthetic disturbance, dysmasesis and phonation disorder by attrition. She had severe attrition of almost teeth. To avoid metal color exposure and attrition of opposing teeth, hybrid ceramics were used for veneered crowns and fixed partial denture. Since the prosthetic treatment, the patient wears a night guard to prevent attrition of her teeth and prosthesis. DISCUSSION: There has been no specific trouble during the 4-year follow-up. CONCLUSION: It is considered that using hybrid ceramics for veneering crowns and fixed partial denture and night guard help to prevent the attrition of opposing teeth and abrasion of prosthesis.

Ceramics↗

Eyelids and eye socket reconstruction using the expanded forehead flap and scapha composite grafting.

After trauma or excision of malignant tumor, it is difficult to achieve satisfactory results when reconstructing deformed eyelids and the socket for an ocular prosthesis. The authors demonstrate examples of successful reconstruction for a prosthetic eye that provided adequate and aesthetic soft-tissue support achieved by applying a three-step surgical procedure of reconstruction of the eye socket, the eyelids, and the tarsus and eyelid margin. Because it is highly vascularized and its distal end can be divided into two or three portions for easy three-dimensional reconstruction, the expanded forehead flap alone, with a galea flap, or with a free rectus abdominis muscle perforator flap was used. The expanded forehead flap also provides excellent thin upper lid contour and good color-matching with a recipient site. For the eye socket, sufficient volume of tissue was provided from the expanded forehead flap with or without a galea or a free rectus abdominis muscle perforator flap, and a deep and convex fornix was formed. This resulted in a good fit and in stability of the ocular prosthesis. The surface and the inner lining of the eyelids were reconstructed using portions of the expanded forehead flap. For the tarsus and eyelid margin, conventional reconstruction techniques use cartilage of the concha, which has limitations of length and which does not fit the shape of the tarsal margin. The authors used the scapha composite graft, and a natural shape and good elasticity resulted.

Adult↗

Predicting hemodialysis access failure with color flow Doppler ultrasound.

Color flow doppler ultrasound examination of the hemodialysis access was conducted in 2,792 hemodialysis patients to evaluate its value in predicting hemodialysis access failure. After baseline assessment of vascular access function with clinical and laboratory tests including color flow doppler evaluation these patients were followed for a minimal of 6 months or until graft failure occurred (defined as surgery or angioplasty intervention, or graft loss). The patient demographics and vascular accesses were typical of a standard hemodialysis patient population. On the day of the color flow doppler examination systolic and diastolic blood pressure, hematocrit, urea reduction ratio, dialysis blood flow, venous line pressure at a dialysis blood flow of 250 ml/min, and access recirculation rate were measured. At the conclusion of the study 23.5% of the patients had access failure. Case mix predictors for access failure were determined using the Cox Model. Case mix predictors of access failure were race, non-white was higher than white (p < 0.005), younger accesses had a higher risk than older accesses (p < 0.025), accesses with prior thrombosis had a higher risk of failure (p=0.042), polytetrafluoroethylene (PTFE) grafts had a higher risk than native vein fistulae (p < 0.05), loop PTFE grafts had a higher risk than straight PTFE grafts (p < 0.025), and upper arm accesses had a higher risk than forearm accesses (p=0.033). Most significant, however, was decreased access blood flow as measured by color flow doppler (p < 0.0001). The relative risk of graft failure increased 40% when the blood flow in the graft decreased to less than 500 ml/min and the relative risk doubled when the blood flow was less than 300 ml/min. This study has shown that color flow doppler evaluation, quantifying blood flow in a prosthetic graft, can identify those grafts at risk for failure. In contrast, color doppler volume flow in native AV fistulae could not predict fistula survival. This technique is noninvasive, painless, portable, and reproducible. We believe that preemptory repair of an anatomical abnormality in vascular access grafts with decreased blood flow may decrease patient inconvenience, associated morbidity, and associated costs.

Arteriovenous Shunt, Surgical↗

Femoropopliteal arteries: immediate and long-term results with a Dacron-covered stent-graft.

PURPOSE: To assess immediate and long-term outcome after femoropopliteal implantation of a Dacron-covered stent-graft in patients with peripheral arterial disease. MATERIALS AND METHODS: This prospective cohort study included 30 consecutive patients who underwent Dacron-covered stent-graft implantation because of recurrent stenosis after percutaneous transluminal angioplasty in the femoropopliteal segment. After interventional treatment, 100 mg of acetylsalicylic acid daily and oral anticoagulation therapy (therapeutic level, international normalized ratio, 2.0-3.0) were administered. Patients were followed up with ankle-brachial index measurement, color-coded duplex ultrasonography, and angiography. Primary and secondary patency rates and postintervention complications were documented as was initial technical success. Kaplan-Meier and life table analyses were used for calculation of patency rates. RESULTS: Initial technical success was achieved in all 30 patients, with significant improvement of ankle-brachial index from a preintervention mean of 0.5 +/- 0.14 (SD) to a postintervention mean of 0.8 +/- 0.17 (P <.001). Postimplantation noninfectious fever and leukocyte and C-reactive protein level elevation occurred in 12 patients (40%), and 17 patients (57%) reported persistent pain at the site of implantation for a mean of 5 days (range, 2-28 days). Early recurrent occlusion within the first 24 hours was found in five patients (17%). Within the mean follow-up period of 60 months +/- 10, restenosis occurred in 25 patients (83%). At 6, 12, 36, and 72 months, respectively, primary patency rates were 27%, 23%, 17%, 17%, and secondary patency rates were 63%, 60%, 34%, 34%. CONCLUSION: Implantation of Dacron-covered stent-grafts for treatment of femoropopliteal lesions leads to high early and late restenosis rates, with a considerable rate of complications, such as fever and pain.

Aged↗

Colour-coded duplex imaging can safely replace diagnostic arteriography in patients with lower-limb arterial disease.

The purpose of this study was to review the outcome of adopting colour-coded duplex ultrasonography as the primary imaging modality in patients with symptomatic lower-limb arterial disease. Over a 12-month period 467 consecutive lower-limb duplex scans were performed of which 437 (94 per cent) were technically adequate. Of the 467 limbs, 184 (39 per cent) were managed conservatively, 230 (49 per cent) were referred for percutaneous transluminal angioplasty (PTA), 41 (9 per cent) underwent reconstructive surgery and 12 (3 per cent) required diagnostic arteriography. In patients referred for PTA there were only 22 (10 per cent) unexpected findings; there was agreement about superficial femoral artery occlusion length in 95 (89 per cent) of 107 limbs and about the presence or absence of a superficial femoral artery stump in 91 (85 per cent) of 107 cases. In patients referred for surgery there were no unexpected findings. Colour-coded duplex imaging can safely replace diagnostic arteriography in up to 97 per cent of lower limbs with arterial disease.

Adult↗

Hereditary multiple exostoses with pseudoaneurysm.

A 16-year-old male patient with hereditary multiple exostoses (HME) was found to have a pseudoaneurysm of the left popliteal artery caused by osteochondroma in the lower femur. The diagnosis was confirmed by ultrasound, magnetic resonance imaging and magnetic resonance angiography without the need to perform an angiogram. The osteochondroma was excised and the popliteal artery was repaired with a saphenous graft. Vascular complications are extremely rare in HME, pseudoaneurysm being the most common and mostly located in the popliteal artery. This complication should be considered in young HME patients with a mass at the knee region. The radiological spectrum of investigations allows the diagnosis of this complication with proper and less invasive management procedures for the patient.

Adolescent↗

Duplex ultrasound criteria for femorofemoral bypass revision.

PURPOSE: This study was conducted to evaluate the impact of duplex ultrasound surveillance on the patency of femorofemoral bypasses performed for symptomatic peripheral arterial occlusive disease (PAOD). METHODS: A retrospective review was conducted of 108 patients (78 men, 30 women) with a mean age of 62 +/- 10 years who underwent femorofemoral prosthetic (n = 100) or vein (n = 8) bypass grafting for symptomatic PAOD (claudication, 38%; rest pain, 41%; tissue loss, 11%; infection, 10%) during a 10-year period. Prior or concomitant inflow iliac artery stenting was performed in 26 patients (24%), and a redo femorofemoral bypass was performed in 19 patients (18%). Duplex ultrasound surveillance of the reconstruction was performed at 6-month intervals to assess patency, graft (midgraft peak systolic flow velocity) hemodynamics, and identify inflow or outflow stenotic lesions. Repair was recommended for a stenosis with a peak systolic velocity (PSV) >300 cm/s and a PSV ratio >3.5. Life-table analysis was used to estimate primary, assisted-primary, and secondary graft patency. RESULTS: During a mean 40-month follow-up (range, 2 to 120 months), 31 bypasses (29%) were revised: 19 duplex-detected stenosis involving the inflow iliac artery (n = 15) or anastomotic stenosis (n = 4), or both, 11 for graft thrombosis, and 1 for graft infection. Abnormal inflow iliac (PSV >300 cm/s) hemodynamics or a mid-graft PSV <60 cm/s was measured in eight of 11 grafts before thrombosis. Mean time to revision was 30 +/- 17 months. The primary graft patency at 1, 3, and 5 years was 86%, 78%, and 62%, respectively. Correction of duplex-detected stenosis resulted in assisted-primary patency of 95% at 1 year and 88% at 3 and 5 years (P < .0001, log-rank). Secondary graft patency was 98% at 1 year and 93% at 3 and 5 years. CONCLUSIONS: Vascular laboratory surveillance after femorofemoral bypass that included duplex ultrasound imaging of the inflow iliac artery and graft accurately identified failing grafts. A duplex-detected identified stenosis with a PSV >300 cm/s correlated with failure, and repair of identified lesions was associated with excellent 5-year patency.

Aged↗

Heart diseases following mediastinal irradiation: surgical management.

Twelve patients underwent cardiac surgical procedures after having previously received irradiation of the mediastinum for various types of malignancies (Hodgkin's disease, carcinoma of the breast and seminoma). The patients' ages ranged from 39 to 69 years (mean 57 years); nine patients were female and three male. The average length of time from radiation to surgery was 15 years (3-24 years interval). The patients were divided into two groups according to the type of heart disease: Group I included seven patients who developed coronary artery disease (CAD) despite minimal risk factors. Three asymptomatic patients developed sudden myocardial infarction. In two patients the myocardial infarction was complicated (with ventricular septal defect in one and ventricular septal defect plus ventricular aneurysm in the other). All seven patients were surgically managed. Internal thoracic artery (ITA) was used in three patients as a conduit of myocardial revascularization. There were two hospital deaths in this group. The five patients in Group II underwent aortic valve replacement for aortic stenoses. Prior to the irradiation, none of the patients had a documented history of rheumatic fever, bacterial endocartitis, significant murmur, etc. There were no deaths in this group. Intraoperative findings for both groups included thickening and/or fibrosis of the ascending aortic wall, coronary arteries and aortic valve tissue. Epicardium was whitish colored and thickened.

Adult↗

Graft patency evaluation with colour-Doppler ultrasonography after bypass surgery in Takayasu's arteritis: a direct colour-flow lumen imaging method.

OBJECTIVES: To assess the feasibility and potential diagnostic usefulness of colour-Doppler flow imaging (CDFI) to detect complications of supra-aortic vascular bypass grafts in Takayasu's arteritis (TA). DESIGN: A prospective study. MATERIALS: Nine supra-aortic grafts in six patients with Takayasu's arteritis. METHODS: The minimal, maximal, and true colour-flow image diameters of the lumens of the grafts were measured and stenoses, occlusions, and dilatations were evaluated and compared with angiographic findings. RESULTS: The sensitivity for detection in > 50% stenoses and in total occlusions was 75% while specificity was 100%. Only one 40% stenosis had been overlooked in whole. The maximal difference of stenosis by two methods was otherwise 20%. CONCLUSIONS: CDFI was in general able to expose stenoses in supra-aortic grafts, but the lack of visibility of some grafts throughout their length cause the false results. It appears that some angiographies can be replaced by CDFI and that this is a suitable method for follow-up in symptom-free patients with grafts.

Adult↗

Postoperative radiology of endovascular abdominal aortic aneurysm repair.

This article addresses the imaging appearances following endovascular abdominal aortic aneurysm repair (EVAR). EVAR is gaining popularity and hence there is increasing likelihood that radiologists who are unfamiliar with the procedure will report imaging investigations on these patients. We describe the technique, failure modes, complications, and postoperative imaging features of this procedure.

Aortic Aneurysm, Abdominal↗

Spontaneous dissection of the infrarenal abdominal aorta.

Spontaneous infrarenal abdominal aortic dissection is rare. We observed enlargement of a spontaneous infrarenal aortoiliac dissection in a 55-year-old hypertensive man. Open surgical repair with a bifurcated polyester graft was successful. A review of the English literature found 41 previously published cases. Mean age was 58 years, 74% of the patients were male, and 62% had hypertension. None had Marfan or Ehlers-Danlos syndrome. More than three fourths of the patients had symptoms, 6 patients (14%) presented with aortic rupture. Dissection was limited to the infrarenal aorta in 50% and extended into the iliac or femoral arteries in 50%. Three patients died before treatment, no death occurred after endovascular repair of after elective open aortic grafting. Mortality following rupture was 67%. Abdominal aortic dissection did not reoccur but 1 patient died at 14 month because of rupture of a thoracic aneurysm. Spontaneous infrarenal abdominal aortic dissections are rare, but usually symptomatic and 14% rupture. Rupture carries high mortality. Elective open repair is recommended, but endovascular repair is a new treatment option for suitable patients.

Aortic Dissection↗

Aesthetics and biocompatibility: strong, electroformed, pure gold for PFM crowns and bridges.

The plethora of base-mental alloys and metal-free restorations and ever rising cost of palladium alloys has given this full-feature PFM system a definite place in modern dentistry. Thanks to the minimum tooth reduction necessary, GES PureGold has a number of clinical and aesthetic advantages. The system's gold substructures are my choice because they provide natural color beneath ceramics, a high degree of biocompatibility, and exquisite marginal integrity.

Biocompatible Materials↗

Simultaneous aortoiliac reconstruction and renal transplantation: is it safe?

A 54-year-old man with an aortoiliac aneurysm and renal failure due to renal artery thrombosis was placed on a transplantation waiting list. The aneurysm had a 3 cm diameter and, therefore, did not require aortoiliac reconstruction, while its evolution was followed by ultrasound color-doppler every six months. The aneurysm was stable and two years later, when a cadaver kidney became available, a preoperative ultrasound color-doppler showed initial wall dissection. Therefore, an abdominal aneurysmectomy using a standard Dacron bifurcation graft and renal transplantation were successfully carried out. The patient had no associated complications and 24 months after transplantation and aneurysmectomy currently has good renal function and distal pulses. Only 20 cases of simultaneous aortoiliac reconstruction and renal transplantation have been reported in the literature. The excellent results of our case and those reported in the literature prove that patients who have both severe aortoiliac disease and end-stage renal failure can safely undergo simultaneous aortic reconstruction and renal transplantation. However, the atherosclerosis in these patients is a generalized process, so that in the pretransplant protocol special attention should be paid to detecting coronary artery atherosclerosis. In fact, coronary artery disease may have a priority claim to therapy because of the high risk of myocardial infarction. Our own policy is to put the patient back on the waiting list for renal transplantation after treatment for coronary artery disease. Furthermore, considering that the management for aortoiliac disease and kidney failure is safe in both simultaneous and staged cases, we think that the real issue is whether or not these patients with coronary atherosclerosis can be candidates for renal transplantation. We believe that each transplant centre has to develop its own general policy for these critically ill patients on the basis of its own experience.

Aortic Dissection↗

[Quantification of mitral prosthesis failure by different methods of evaluation by transesophageal echocardiography].

PURPOSE: To evaluate the different methods for grading mitral regurgitation (MR) by transesophageal echocardiography (TEE) in patients with clinical suspicion of mitral prosthesis dysfunction. METHODS: Cardiac catheterization (Cath) was performed in 15 patients for grading the severity of prosthetic MR, divided in two groups based on the presence or absence of severe MR. Prosthetic MR was quantified by TEE using methods commonly used for MR of native valves: subjective assessment by color Doppler, objective assessment based on absolute jet area and on its relative area (jet area/left atrial area) and assessment based on the presence of systolic flow reversal in pulmonary vein. RESULTS: Prosthetic MR was mostly transprosthetic (14 patients) and eccentric (11 patients). There was significant correlation (p < 0.05) between Cath and TEE for identification of severe MR based on subjective assessment and on the presence of systolic flow reversal in pulmonary vein. Identification based on absolute (jet area > 7 cm2) and relative (jet area > 35% of left atrial area) jet areas did not reveal significant correlation with the angiographic grade and showed clear underestimation by TEE when the last method was used. However, there was good correlation (p < 0.05) if relative jet areas > 30% were considered as cut point. CONCLUSION: TEE correctly identified angiographic severe mitral prosthesis regurgitation, mainly by the presence of systolic flow reversal in pulmonary vein and subjective assessment. The estimation of severity of the prosthetic MR by absolute or relative jet area seems to be limited and should be used with caution due to eccentricity of the regurgitant jet, frequently seen in mitral prosthesis dysfunction.

Adult↗

[Thrombosis of atrioventricular prosthesis. Contribution of transesophageal echocardiography].

The aim of this study was to assess the diagnostic value of transesophageal echocardiography for the detection of thrombosis of a mechanical mitral or tricuspid valve prosthesis. Twelve patients (mean age 54 +/- 12 years) out of a series of 39 patients operated between April 1988 and June 1989 for prosthetic valve dysfunction had valve thrombosis at operation (11 mitral and 1 tricuspid valve prosthesis). Transesophageal echocardiography was routinely performed preoperatively in addition to transthoracic Doppler echocardiography to search for an abdominal mass on the prosthetic valves. The largest diameter of the diastolic jet at the level of the prosthetic valve annulus was measured using transesophageal color flow Doppler in the 8 Starr-Edwards mitral valve prostheses and compared with 5 control valves. The results of transthoracic Doppler echocardiography and transesophageal echocardiography were compared with the operative findings. The specificity of transthoracic echocardiography for the positive diagnosis of prosthetic valve thrombosis was 18%. A thrombosis could be suspected in 10 of the 12 cases by transthoracic echocardiography giving a sensitivity of 83%. Eleven of the 12 abnormal masses on the prostheses were visualised by transesophageal echocardiography, a sensitivity of 91%. Detection of the masses on the arterial side was possible in all cases (10/10) but 5 of the 6 extensions of the thrombus into the ventricle could not be visualised. The diameter of the transprosthetic jet was less than 12 mm in 7 of the 8 thrombosed valves compared with greater than 15 mm in the 5 normal control prostheses.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Color duplex ultrasonography of the superior mesenteric artery after placement of endografts with suprarenal stents.

After endovascular repair of abdominal aortic aneurysm with endografts with suprarenal stents, the proximal uncovered stent may cross the origin of the superior mesenteric artery. Effects on splanchnic circulation are unknown and may include development of stenosis at the vicinity of the stent. The criteria of high-grade superior mesenteric artery stenosis using color duplex ultrasonography have been previously reported. The purpose of this study is to examine the incidence of high-grade superior mesenteric artery stenosis in patients with endografts with suprarenal stents using color duplex ultrasonography. Candidates for the study were patients who had placement of an aortic endograft with a suprarenal stent and were able to undergo ultrasonography of the superior mesenteric artery. After reviewing computed tomography scans, patients who had the origin of the superior mesenteric artery crossed by the suprarenal stent underwent color duplex ultrasonography of this vessel. Presence of turbulence or narrowing of the superior mesenteric artery, or a peak systolic velocity greater than 2.75 m/sec, or an end-diastolic velocity greater than 0.45 m/sec were considered significant for the presence of high-grade superior mesenteric artery stenosis. There were 24 patients (21 males, three females), median age 71 years (range, 59-83). The suprarenal stent was crossing the superior mesenteric artery in 17 of 24 patients (71%). Color duplex ultrasound was technically successful in 13 of 17 (76%). The test was performed after a median follow-up of 9 months (range, 3 days to 34 months). No patient had evidence of turbulence or narrowing of the superior mesenteric artery during ultrasonography. The median peak systolic velocity was 0.92 m/sec (range, 0.53-1.21 m/sec). No patient had peak systolic velocity greater than 2.75 m/sec. The median end-diastolic velocity was 0.10 m/sec (range, 0.09-0.14 m/sec). No patient had end-diastolic velocity greater than 0.45 m/sec. Color duplex ultrasonography did not demonstrate the presence of high-grade superior mesenteric artery stenosis during early follow-up of patients with endografts with suprarenal stents. Longer follow-up of larger series of patients is needed to determine the long-term effects of suprarenal stents on splanchnic circulation.

Aged↗