Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Models, Anatomic”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68Linked to original sources

A multipurpose template for implant placement.

A case report is presented describing the laboratory fabrication and clinical use of an innovative template. This template was designed to function as a radiographic implant positioning guide, accurate bone sounding guide, and surgical guide. This appliance is intended to serve additional roles as an aid in flap reflection and as a pick-up impression tray.

Dental Implantation, Endosseous↗

Three-dimensional guidance system for implant insertion: Part II. Dual axes table--problem solving.

The three-dimensional guidance system for implant insertion is a technique for placing a radiopaque vertical orientation pin over the crest of the alveolar ridge on the stone cast during fabrication of the radiographic guide. The cross-sectional and panoramic reformatted images were reproduced on a Polaroid or 35-mm print. The true vertical orientation pin facilitates (1) identification and the exact planned location of each implant in the reformatted images of the CT scan, (2) establishment of the internal starting point for the osteotomy on a photographic print, (3) optimum implant orientation, and (4) measurement of the angulation between the true vertical orientation line and optimum implant orientation. With the aid of a newly developed dual-axes base and transfer of the internal starting point of each implant to the stone cast, the buccolingual and mesiodistal implant inclinations for each implant were transferred to a surgical guide in the form of surgical steel drill guide tubes. The resulting pilot osteotomy transfers to the alveolar bone the exact starting point and the buccolingual and mesiodistal inclination for each implant. The technique provides a three-dimensional guidance system for implant insertion that is extremely accurate and yet practical.

Anatomy, Cross-Sectional↗

An optical model of the human retinal nerve fiber layer: implications of directional reflectance for variability of clinical measurements.

PURPOSE: The reflectance of the retinal nerve fiber layer is highly directional--that is, it depends strongly on the angles of illumination and viewing. This study explored and illustrated the implications of this directional reflectance for nerve fiber layer measurements in the human eye. METHODS: The retina was modeled as a sphere centered on the optic axis of a schematic eye. Nerve fiber ribbons were projected onto the retina and cylindrical light scattering was calculated along each ribbon. The reflectance along the ribbon was then determined for the illuminating and viewing apertures of two hypothetical optical instruments, a fundus camera and a confocal scanning laser ophthalmoscope. Results were displayed as reflectance maps. RESULTS: Uniformly illuminated nerve fiber ribbons exhibited a nonuniform reflectance pattern that was very sensitive to the location in the pupil of the instrument apertures. Ribbon reflectance at the superior and inferior disc margins varied with ribbon orientation, being higher with temporal tilt and lower with nasal tilt. Ribbons nasal to the disk could be quite dim. CONCLUSIONS: In quantitative nerve fiber layer assessment technologies, the observed reflectance depends on the configuration of the illuminating and viewing apertures of the measuring instrument and on the retinal position and orientation of each nerve fiber bundle. In clinical practice, this dependence may cause significant measurement variability that can be reduced by specific measurement maneuvers.

Fundus Oculi↗

Computer-assisted total knee arthroplasty using patient-specific templating.

Current techniques used for total knee arthroplasty rely on conventional instrumentation that violates the intramedullary canals. Accuracy of the instrumentation is questionable, and assembly and disposal of the numerous pieces is time consuming. Navigation techniques are more accurate, but their broad application is limited by cost and complexity. We aimed to prove a new concept of computer-assisted preoperative planning to provide patient-specific templates that can replace conventional instruments. Computed tomography-based planning was used to design two virtual templates. Using rapid prototyping technology, virtual templates were transferred into physical templates (cutting blocks) with surfaces that matched the distal femur and proximal tibia. We performed 45 total knee arthroplasties on 16 cadaveric and 29 plastic knees, including a comparative trial against conventional instrumentations. All operations were performed using patient-specific templates with no conventional instrumentations, intramedullary perforation, tracking, or registration. The mean time for bone cutting was 9 minutes with a surgical assistant and 11 minutes without an assistant. Computer-assisted analyses of six random computed tomography scans showed mean errors for alignment and bone resection within 1.7 degrees and 0.8 mm (maximum, 2.3 degrees and 1.2 mm, respectively). Patient-specific templates are a practical alternative to conventional instrumentations, but additional clinical validation is required before clinical use.

Aged↗

Contact stress in hips with osteonecrosis of the femoral head.

Contact stress distribution in the articular surface of the hip is considered a factor in the development of osteoarthritis, a common complication in hips with aseptic necrosis of the femoral head. We present evidence supporting the hypothesis that osteoarthritis in hips with aseptic necrosis of the femoral head can be caused by elevated contact stress related to the reduced load-bearing ability of the necrotic bone. By using a previously validated mathematical model, we observed that hip contact stress may increase considerably if the load-bearing capacity of the necrotic lesion is decreased, if the size of the necrotic segment is increased, and if the necrotic segment is located more laterally. These effects are affected by the intrinsic shape of the hip. As the estimated values of stress in hips with osteonecrosis are in the range obtained by the same method in dysplastic hips, osteoarthritis in hips with osteonecrosis can be caused by elevated contact stress.

Biomechanical Phenomena↗

Effects of slip severity and loading directions on the stability of isthmic spondylolisthesis: a finite element model study.

STUDY DESIGN: Using a validated finite element model, the biomechanical effects of pars defect in a lumbar segment with and without different degrees of slip (up to 50% slip) were studied. OBJECTIVES: To study the effects of slip severity and loading parameters on the stability of the lytic and adjacent motion segments. Better knowledge of the biomechanics of spondylolisthesis may help formulate treatment strategies such as bracing or spinal implants. SUMMARY OF THE BACKGROUND DATA: Clinically, spondylolisthesis exists in varying grades of anterior slip, and the biomechanical stability of the motion segments at the lytic defect and adjacent level probably varies as well. In vitro studies of L4-L5 and L5-S1 isthmic spondylolisthesis slips have concluded that an L4-L5 pars defect is more unstable than an L5-S1 pars defect. Comparing the stability of lytic motion segments with different grades of spondylolisthesis is difficult to do experimentally and therefore has not been done. Further assessing the stresses in the bone and intervertebral discs at or adjacent to a lytic defect is also difficult to study experimentally, so no data are available. METHODS: A finite element model of L4-S1 was validated with and without a pars defect at L5. The model was then revised to represent different degrees of slip at L5, and six different moment loadings were applied. RESULTS: The current study showed larger decrease in stiffness with increasing percent slip. The decrease in disc stiffness and increase in disc stresses with increasing percent slip were larger at the level of spondylolisthesis as compared to the changes in the adjacent segment. Lateral bending moment and torsion load showed the largest decrease in stiffness due to slip. At 50% slip, the maximum increase in motion (as compared to motion in an intact segment) was seen under lateral bending moment load (about 55% at L4/L5 and 250% at L5/S1). Lateral bending also produced the largest increase in stresses due to 50% slip in the anulus and endplates (300% increase in anular stress and 190% increase in endplate stress) at L5/S1. CONCLUSIONS: The stiffness of a spondylolisthetic motion segment decreases as the slip increases. Lateral bending and torsion are moment directions causing the greatest resulting motions.

Biomechanical Phenomena↗

Interbody fusion cage design using integrated global layout and local microstructure topology optimization.

STUDY DESIGN: An approach combining global layout and local microstructure topology optimization was used to create a new interbody fusion cage design that concurrently enhanced stability, biofactor delivery, and mechanical tissue stimulation for improved arthrodesis. OBJECTIVE: To develop a new interbody fusion cage design by topology optimization with porous internal architecture. To compare the performance of this new design to conventional threaded cage designs regarding early stability and long-term stress shielding effects on ingrown bone. SUMMARY OF BACKGROUND DATA: Conventional interbody cage designs mainly fall into categories of cylindrical or rectangular shell shapes. The designs contribute to rigid stability and maintain disc height for successful arthrodesis but may also suffer mechanically mediated failures of dislocation or subsidence, as well as the possibility of bone resorption. The new optimization approach created a cage having designed microstructure that achieved desired mechanical performance while providing interconnected channels for biofactor delivery. METHODS: The topology optimization algorithm determines the material layout under desirable volume fraction (50%) and displacement constraints favorable to bone formation. A local microstructural topology optimization method was used to generate periodic microstructures for porous isotropic materials. Final topology was generated by the integration of the two-scaled structures according to segmented regions and the corresponding material density. Image-base finite element analysis was used to compare the mechanical performance of the topology-optimized cage and conventional threaded cage. RESULTS: The final design can be fabricated by a variety of Solid Free-Form systems directly from the image output. The new design exhibited a narrower, more uniform displacement range than the threaded cage design and lower stress at the cage-vertebra interface, suggesting a reduced risk of subsidence. Strain energy density analysis also indicated that a higher portion of total strain energy density was transferred into the new bone region inside the new designed cage, indicating a reduced risk of stress shielding. CONCLUSION: The new design approach using integrated topology optimization demonstrated comparable or better stability by limited displacement and reduced localized deformation related to the risk of subsidence. Less shielding of newly formed bone was predicted inside the new designed cage. Using the present approach, it is also possible to tailor cage design for specific materials, either titanium or polymer, that can attain the desired balance between stability, reduced stress shielding, and porosity for biofactor delivery.

Algorithms↗

Biomechanical effects of C2-C7 intersegmental stability due to laminectomy with unilateral and bilateral facetectomy.

STUDY DESIGN: The biomechanical responses resulting from laminectomy with graded unilateral and bilateral facetectomy were quantified using a three-dimensional nonlinear finite element model of the C2-C7 motion segments. OBJECTIVE: To study the influence of laminectomy with graded unilateral and bilateral facetectomy on the cervical spinal biomechanics. SUMMARY OF BACKGROUND DATA: Cervical spinal stenosis is a condition that is caused by the narrowing of the spinal canal. Laminectomy and facetectomy are commonly used surgical procedures for decompressing cervical spinal stenosis. Resection of the posterior structures causes instability and affects the internal stresses of the cervical spinal components. However, the influence of these surgical procedures on the biomechanical responses of the cervical spine has not been studied. METHODS: A nonlinear finite element model of the intact C2-C7 was constructed and validated. Ten surgically altered models were created from the intact model and were tested under physiologic loading. Because of the inclusion of five motion segments, it was possible to determine the intersegmental responses and internal cortical shell and disc stresses in the adjacent altered and unaltered spinal components. RESULTS: Under combined flexion and extension, intersegmental motions at C4-C5 and C5-C6 increased significantly after C5 laminectomy. Subsequent facetectomy performed at C5 and C6 on the laminectomized model only affected the responses at the C5-C6 segment. Overall, slight intersegmental responses of up to 5% were observed at the adjacent levels of C3-C4 and C6-C7. Laminectomy did not cause any significant increase in the intersegmental motions under lateral bending and axial rotation. Extending the surgical procedures to unilateral and bilateral facetectomy only increased the intersegmental motions slightly. Similar increases in the intervertebral disc and the cortical shell stresses were observed. These findings may partially explain the clinical observations of enhanced osteophytes formation. CONCLUSIONS: This study provides a better understanding of the surgically altered cervical spinal biomechanics and may help formulate treatment strategies such as spinal implants.

Biomechanical Phenomena↗

Using a finite element model to evaluate human injuries application to the HUMOS model in whiplash situation.

STUDY DESIGN: In the field of numerical simulation, the finite element method provides a virtual tool to study human tolerance and postulate on potential trauma under crash situations, particularly in case of whiplash trauma. OBJECTIVES: To show how medical and biomechanical interpretations of numerical simulation can be used to postulate on human injuries during crash situations. This methodology was applied to whiplash trauma analysis. A detailed analysis of kinematics of joints, stress level in hard tissues, and strain level in soft tissues was used to postulate on chronology and patterns of injury. Data were compared with published biomechanical and clinical studies of whiplash. SUMMARY OF BACKGROUND DATA: Although many in vitro and in vivo studies have been conducted to investigate whiplash cervical injury, and despite the number of finite element models developed to simulate the biomechanical behavior of the cervical spine, to date, there are only limited finite element models reported in the literature on the biomechanical response of the whole cervical spine in these respects. METHODS: A complete finite element model of the human body (HUMOS) build in a sitting position in a car environment was created to investigate injury mechanisms and to provide data for automotive safety improvements. It includes approximately 50,000 elements, including descriptions of all bones, ligaments, tendons, skin, muscles, and internal organs. A 15-g whiplash injury was simulated with the HUMOS model. The model predicted cervical motion segment kinematics, deformations of disks and ligaments, and stresses in bone. Model output was then compared with experimental and clinical whiplash literature. RESULTS: In term of kinematics during the chronology of whiplash, two injury phases were identified: the first was hyperextension of the lower cervical spine (C6-C7 and C5-C6) and mild flexion of the upper cervical spine(C0-C4). The amount of upper cervical flexion was 15 degrees from C0 to C4. The second phase was hyperextension of the entire cervical spine. Potential patterns of ligamentous injuries were observed; the anterior longitudinal ligament experienced the most strain (30%) at the lower cervical spine at the time of lower cervical extension and the interspinous ligament experienced the most strain (60%) at the time of upper cervical flexion. Von Mises stresses in bone do not exceed 15 Mpa, which is largely under injury levels reported in the literature. CONCLUSIONS.: This study reports a methodology to describe and postulate on human injuries based on finite element model analysis. The output of the HUMOS model in the context of whiplash shows a strong correlation with clinical and experimental reported data. HUMOS shows promise for the modeling of other types of trauma as well.

Biomechanical Phenomena↗

The effects of rod contouring on spinal construct fatigue strength.

STUDY DESIGN: In vitro fatigue loading using a corpectomy model outfitted with posterior pedicle screw instrumentation. OBJECTIVE: The purpose of this study was to detect differences in fatigue resistance of titanium and stainless steel spinal constructs that use rods contoured using a French Bender, and to compare differences in fatigue resistance of contoured and straight titanium rods. SUMMARY OF BACKGROUND DATA: Instrumentation failure is generally thought to be caused by fatigue or cyclic loading. Intraoperative contouring of the posterior rods is almost always required to match the native kyphotic (thoracic) or lordotic (cervical or lumbar) spinal curvature. How bending these rods affects their overall fatigue resistance is not well described. In addition, changes in fatigue resistance may be a function of material type. METHODS: Spinal constructs were evaluated using the ASTM F1717-01 model. Two different titanium-based rods (Ti6AL4V and CpTi) and two different steel-based rods (Orthinox and 316L stainless steel) were evaluated in this study (n = 6 for each group). Rods were contoured at two points using a French Bender and were rigidly coupled to polyaxial pedicle screws within UHMWPE vertebral bodies. Constructs were cycled at a load ratio of 10 between a minimum and maximum loading regime of -250 N/-25 N and -700 N/-70 N at a frequency of 4 Hz. Estimated maximum nominal stresses at various points of interest in the spinal constructs were calculated using beam theory. Effects of the rod material, load, and stress on the number of cycles to failure were analyzed using Cox proportional hazards regression. RESULTS: All of the spinal constructs with contoured CpTi rods and contoured Ti6Al4V rods failed at one of the bends in the rods. Almost all of the spinal constructs with straight CpTi rods and straight Ti6Al4V rods failed where the blocker screw fastens the rod to the coupler of the polyaxial screw head. Contoured titanium constructs demonstrated significantly lower fatigue life than contoured 316L constructs. Contouring tended to lower the fatigue life of both the Ti6Al4V and CpTi constructs. CONCLUSION: Intraoperative rod contouring using a French Bender significantly reduces the fatigue life of titanium spinal constructs.

Bone Nails↗

A kinematic model to assess spinal motion during walking.

STUDY DESIGN AND OBJECTIVES: A 3-dimensional multi-segment kinematic spine model was developed for noninvasive analysis of spinal motion during walking. Preliminary data from able-bodied ambulators were collected and analyzed using the model. SUMMARY OF BACKGROUND DATA: Neither the spine's role during walking nor the effect of surgical spinal stabilization on gait is fully understood. Typically, gait analysis models disregard the spine entirely or regard it as a single rigid structure. Data on regional spinal movements, in conjunction with lower limb data, associated with walking are scarce. METHODS: KinTrak software (Motion Analysis Corp., Santa Rosa, CA) was used to create a biomechanical model for analysis of 3-dimensional regional spinal movements. Measuring known angles from a mechanical model and comparing them to the calculated angles validated the kinematic model. Spine motion data were collected from 10 able-bodied adults walking at 5 self-selected speeds. These results were compared to data reported in the literature. RESULTS: The uniaxial angles measured on the mechanical model were within 5 degrees of the calculated kinematic model angles, and the coupled angles were within 2 degrees. Regional spine kinematics from able-bodied subjects calculated with this model compared well to data reported by other authors. CONCLUSIONS: A multi-segment kinematic spine model has been developed and validated for analysis of spinal motion during walking. By understanding the spine's role during ambulation and the cause-and-effect relationship between spine motion and lower limb motion, preoperative planning may be augmented to restore normal alignment and balance with minimal negative effects on walking.

Adult↗

Development of a percutaneous pediatric ventricular assist device.

Remarkable progress has been made on ventricular assist devices for adult patients. Unfortunately, similar devices are not yet available in the United States for pediatric heart patients. The goal of this project is to demonstrate the feasibility of a percutaneous ventricular assist device for pediatric patients above 2 kg. The proposed system consists of an extracorporeal centrifugal blood pump, a transseptal venous cannula that takes blood from the left atrium to the pump, an arterial cannula that returns the blood to the arterial system, and a controller to adjust pump speed/flow. Using an ad hoc pediatric pump prototype and a spectrum of specially designed cannulae of various sizes, benchtop studies showed that the proposed system could deliver blood flow in a range of 0.3 to 3.0 l/min. For smaller patients (2-35 kg), the transseptal cannula was designed to be placed in the internal jugular vein and the arterial cannula in the internal carotid artery. For larger patients (> 35 kg), the femoral vein and artery would be used. Further development effort will be focused on reducing the hemolysis of the pump design, refining the cannula design, and demonstrating the safety and functionality in animal studies.

Adolescent↗

Correction of compliance and resistance altered by endotracheal tube leaks.

OBJECTIVE: Measurements of lung compliance and resistance are influenced by endotracheal tube leaks. To keep compliance and resistance reliable, we developed an algorithm to correct inspiratory and expiratory volume and flow mathematically. DESIGN: Prospective, clinical study. SETTING: University research laboratory and neonatal intensive care unit. MODEL: A ventilated lung model with a linear pressure-volume relationship and with adjustment of an increasing endotracheal tube leak was investigated. PATIENTS: A total of 21 ventilated premature neonates (median weight, 1220 g; range, 640-2160 g; median leak, 32%; range, 24-56%) were studied. MEASUREMENTS AND MAIN RESULTS: Compliance and resistance were calculated from the recordings of flow, volume, and airway pressure over time employing linear regression of the equation of motion to obtain compliance and resistance. Compliance and resistance altered by leaks were corrected and compared with measurements without leak. Compliance and resistance of the lung model could be corrected up to an endotracheal tube leak size of 86%. Compliance and resistance without leak and after leak correction did not differ significantly for all infants using the linear regression method (p >.05). For the correction of compliance in 15 and for the correction of resistance in 12 of the 21 infants, the coefficients of variation of ten measured breaths without leak were greater or equal to the differences of the values of compliance and resistance between conditions of no leak and corrected leak, respectively. CONCLUSION: Pulmonary compliance and resistance can be reliably corrected even in the presence of a substantial endotracheal tube leak, which makes pulmonary function tests more reliable.

Airway Resistance↗

The effect of striking angle on the buckling mechanism in blowout fracture.

BACKGROUND: The buckling mechanism is widely accepted as a mechanism of blowout fractures, along with the hydraulic mechanism. Although many studies have been performed related to the buckling mechanism, none of them have taken the direction of the striking force into consideration. As the orbital floor is not parallel to the horizontal plane, a difference in the striking force direction might affect resultant fracture patterns. The present study aims to investigate whether fracture patterns in the orbital floor were influenced by the striking force direction in terms of the buckling mechanism. METHODS: The authors produced three-dimensional models on a workstation simulating eight dry skulls and applied striking forces on the orbital rim of each model from three different angles (0, 15, and 30 degrees in the upward direction). Using finite element analysis, the authors calculated the width of the area where the resultant stresses exceed the bone's yielding criterion. The width was termed the "theoretical fracture width" because, theoretically, fracture was expected to occur in the area. Then, the authors compared the theoretical fracture width in groups with the three different striking force angles. Finally, the validity of the theoretical width was verified with an experiment on actual skull models. RESULTS: The theoretical fracture width was the greatest when the striking force was directed at 30 degrees in the upward direction. CONCLUSIONS: For the buckling mechanism, fracture would occur in a wider area of the orbital floor when striking force was directed upward than when the force was horizontally directed. This finding would be helpful in predicting fracture width in blowout fractures.

Biomechanical Phenomena↗

Assessment of shape variation of the levator ani with optimal scan planning and statistical shape modeling.

OBJECTIVE: To capture 3D shape variation of the levator ani during straining with open access MR imaging. METHODS: Optimal scan-planning based on statistical shape modeling is developed for recovering the entire 3D structure of the levator ani from a limited number of 2D imaging planes. Statistical shape modeling ensures optimum material correspondence, and Subspace Reprojection is used to identify the optimum orientation of the imaging plans. The accuracy of the method in using limited 2D imaging planes to instantiate the dynamic structure of the levator ani is assessed with data acquired from 10 asymptomatic subjects. RESULTS: Leave-one-out analysis was performed whereby a model based on a training set consisting of all but one surface was used to instantiate the dynamic surface structure from the corresponding optimal planes. The mean surface distance error for the proposed Subspace Reprojection method is 3.989 +/- 0.790 mm, which is significantly smaller than other approaches. CONCLUSIONS: Surfaces of the levator ani may be instantiated using a limited number of imaging planes as well as a statistical shape model based on a training set of subjects. The proposed technique offers a new way forward for studying dynamic shape changes of 3D structures where complete volumetric imaging is prohibited by the inherent temporal resolution of the scanning technique.

Adult↗

An in vitro analysis of a carotid artery stent with a protective porous membrane.

PURPOSE: To prove the effectiveness of a new stent concept with integrated protection (MembraX [MX]) by comparing it with five cerebral protection devices designed for carotid angioplasty in an in vitro model. MATERIALS AND METHODS: Two simulation series of embolization from carotid angioplasty have been performed. In the first series, polyvinyl-alcohol particles (150-250 microm [small], 355-500 microm [medium], 710-1000 microm [large]; 5 mg each) were injected into a silicone flow model simulating the aortic arch with a carotid bifurcation. The particles were injected proximally to the partially deployed MX stent or one of the following protection devices: Angioguard (AG), FilterWire EX (EX), Trap, Neuroshield (NS), or GuardWire Plus (GW). Particles evading the protection device were caught in a filter at the end of the flow model and weighed. In the second series, human plaque material (8-12 particles; total weight 6.09 +/- 0.01 mg; 500-1500 microm) was injected into the model with the respective devices. MX was compared with the AG, EX, Trap, and NS devices. RESULTS: MX had the most effective overall filtration performance for polyvinyl alcohol particles in the effluent of the internal carotid artery (ICA; 0.43 mg, 2.9%), compared with NS (0.53 mg, 3.5%), GW (1.10 mg, 7.0%), EX and AG (1.18 and 1.21 mg, respectively; 7.8% and 8.0%), and Trap (1.24 mg, 8.2%). MX performed best for the small particles (2.0% passed particles into ICA; P < .05 compared with all). Human plaque material was retained best in the in vitro model by MX (0.0%), followed by NS (0.8%), EX (1.3%), Trap (2.6%), and AG (4.4%). CONCLUSIONS: In vitro, none of the tested devices had the ability to prevent embolization completely. Comparing current designs, the MX device captured the highest percentage of the three different particle groups. Tested with human plaque emboli, MX performed effectively in filtering the particles in the ICA.

Analysis of Variance↗

Oldest true orb-weaving spider (Araneae: Araneidae).

The aerial orb web woven by spiders of the family Araneidae typifies these organisms to laypersons and scientists alike. Here we describe the oldest fossil species of this family, which is preserved in amber from Alava, Spain and represents the first record of Araneidae from the Lower Cretaceous. The fossils provide direct evidence that all three major orb web weaving families: Araneidae, Tetragnathidae and Uloboridae had evolved by this time, confirming the antiquity of the use of this remarkable structure as a prey capture strategy by spiders. Given the complex and stereotyped movements that all orb weavers use to construct their webs, there is little question regarding their common origin, which must have occurred in the Jurassic or earlier. Thus, various forms of this formidable prey capture mechanism were already in place by the time of the explosive Cretaceous co-radiation of angiosperms and their flying insect pollinators. This permitted a similar co-radiation of spider predators with their flying insect prey, presumably without the need for a 'catch-up lag phase' for the spiders.

Animals↗