Potential for artifacts in monitoring for the detection of tumor associated antigens (TAG-72 and CEA) in serum from patients undergoing MAb-based diagnostic and therapeutic protocols.

The administration of murine monoclonal antibodies (MAbs) induces, in many patients, an immunological response represented by the development of human anti-mouse antibodies (HAMA). HAMA have been previously shown to interfere in some assays for the detection of CEA, as well as other non tumor related analytes. The present study was performed to determine whether the CA 72-4 assay is affected by the presence of HAMA, and to establish conditions capable of overcoming this artifact. Serum samples obtained from 8/9 patients entered into a therapeutic protocol using 131I-labeled MAb B72.3 showed the development of apparently high levels of TAG-72 during the clinical follow-up concurrent with the appearance of elevated titers of HAMA. Heat treatment at 90 degrees C at pH 5.0 sodium acetate, previously reported as a method of abolishing HAMA interference without affecting CEA levels, resulted in a considerable loss of detectable TAG-72. However, treatment of these samples at 90 degrees C in pH 6.5 Bis Tris abolished the artifact due to HAMA and resulted in the reversion of reported TAG-72 levels to those observed prior to any MAb administration. As the use of murine MAbs, for both diagnostic and therapeutic applications continues to expand, the identification of this artifactual increase in reported antigen levels due to the development of HAMA has become an important factor in the use of tumor markers, e.g. TAG-72 and CEA, in the follow-up of carcinoma patients.

Animals↗

Use of segmented CT transmission map to avoid metal artifacts in PET images by a PET-CT device.

BACKGROUND: Attenuation correction is generally used to PET images to achieve count rate values independent from tissue densities. The goal of this study was to provide a qualitative comparison of attenuation corrected PET images produced by a PET-CT device (CT, 120 kV, 40 mAs, FOV 600 mm) with and without segmentation of transmission data (ACseg+ and ACseg-respectively). Methods: The reconstructed images were compared to attenuation corrected images obtained with a high-energy transmission source (Cs-137 - 662 keV).Thirty oncologic patients were studied using CT and 137Cs for attenuation correction. All image data were acquired using the Gemini PET-CT scanner (Philips Medical Systems). It is an open PET-CT system that consists of the MX8000 multislice CT and the Allegro PET scanner arranged in a separable configuration. Images with ACseg+ and ACseg- were analyzed simultaneously in coronal, sagittal and transaxial planes. Two nuclear medicine physicians reviewed the image sets. Results: The image quality in the area of metal implants was better with ACseg+ than ACseg-, without metal induced artifacts generally observed in CT corrected images. Further the images with ACseg+ were qualitatively comparable to those obtained with 137Cs attenuation correction. Conclusions: In case of metal implants, PET studies corrected by CT should preferably use the ACseg+ method to avoid the image artifacts.

Journal Article↗

Are hypercontracted muscle fibers artifacts and do they cause rupture of the plasma membrane?

Muscle fibers with hypercontracted zones (contractures) and plasma membrane defects are relatively frequent in Duchenne dystrophy, but artifacts might account for either. To investigate the problem further, we determined the frequency of hypercontracted muscle fibers in longitudinal, trichrome-stained paraffin sections in 143 muscle biopsy specimens in a wide variety of muscle diseases. The specimens were held at rest length during fixation. The incidence of hypercontracted fibers in Duchenne dystrophy was significantly higher than in any of the other diseases or in normal controls. We also induced contractures in rat muscle by fixation without restraint, electrical stimulation, and cutting the muscle fibers in vivo. Electron-microscopy showed no plasma membrane defects associated with the contractures, except in the cut fibers within 25 micron of their cut ends, which were probably overloaded with calcium. The results indicate that (1) in Duchenne dystrophy the contractures in muscle fibers held at rest length during fixation cannot be accounted for by artifact; (2) contractures occurring in normal muscle during fixation do not in and of themselves cause rupture of the muscle fiber plasma membrane.

Animals↗

Removing aperture-induced artifacts from Fourier transform infrared intensity values.

Two Fourier transform infrared intensity artifacts have been observed at moderately high (0.1 cm(-1)) spectral resolution: Light reflected off the aperture was double modulated by the interferometer, producing a 2f alias, and the warm (approximately 310 K) annulus of the aperture seen by a cooled detector resulted in distorted line shapes and anomalous intensities in the fingerprint region. Although the second artifact has been alluded to previously, we report corrections to remove both of these anomalies and to demonstrate the efficacy of these corrections. Prior to correction, integrated-band intensities were found to be in error by up to 12%.

Journal Article↗

Method for reduction of background artifacts of images in scanning holography with a Fresnel-zone-plate coded aperture.

Near-infrared scanning holography with a Fresnel zone plate (FZP) coded aperture has potential applications in imaging through turbid media. However, the nonnegative intensity-distribution function of the FZP coded aperture introduces the background artifacts into the reconstructed images, reducing the contrast and the signal-to-noise ratio (SNR) of the images. A novel method termed as the composite hologram is proposed to reduce the artifacts. The computer simulations showed that the contrast and the SNR of the reconstructed images had improvements of at least 50.2% and 5.58-dB, respectively, compared with the conventional method. The composite hologram of a metal ring with a 6.0-mm diameter made by a wire with a 0.4-mm diameter immersing in 1% intralipid solution was recorded, and the reconstruction was performed numerically. The experimental results demonstrated that the contrast and the SNR of the reconstructed image had improvements of at least 32.3% and 2.51-dB, respectively.

Journal Article↗

Diffractive optical elements designed for highly precise far-field generation in the presence of artifacts typical for pixelated spatial light modulators.

Diffractive optical elements (DOEs) realized by spatial light modulators (SLMs) often have features that distinguish them from most conventional, static DOEs: strong coupling between phase and amplitude modulation, a modulation versus steering parameter characteristic that may not be precisely known (and may vary with, e.g., temperature), and deadspace effects and interpixel cross talk. For an optimal function of the DOE, e.g. as a multiple-beam splitter, the DOE design must account for these artifacts. We present an iterative design method in which the optimal setting of each SLM pixel is carefully chosen by considering the SLM artifacts and the design targets. For instance, the deadspace-interpixel effects are modeled by dividing the pixel to be optimized, and its nearest neighbors, into a number of subareas, each with its unique response and far-field contribution. Besides the customary intensity control, the design targets can also include phase control of the optical field in one or more of the beams in the beam splitter. We show how this can be used to cancel a strong unwanted zeroth-order beam, which results from using a slightly incorrect modulation characteristic for the SLM, by purposely sending a beam in the same direction but with the opposite phase. All the designs have been implemented on the 256 x 256 central pixels of a reflective liquid crystal on silicon SLM with a selected input polarization state and a direction of transmission axis of the output polarizer such that for the available different pixel settings a phase modulation of ~2pi rad could be obtained, accompanied by an intensity modulation depth as high as >95%.

Journal Article↗

Visual artifacts in chromatically subsampled images.

Colors sampled in an array of pixels were converted into various luminance-chrominance representations, and the chrominance values were spatially subsampled to achieve a compression of the data. For viewing, the chrominance values were reinterpolated and then transformed back to RGB. For each of a range of image types and color spaces, we varied the chromatic sample spacing to determine how much compression would be possible before perceptual artifacts appeared, as determined by a panel of individual viewers. The spacing at which an image was mistaken half the time for a remembered original depended on image content and also on the color representation. Some color spaces, such as hue-lightness-saturation, a polar-coordinate color space, are inherently ill suited for chrominance averaging and produce noticeable artifacts on almost any image. Likewise, some images cannot be subsampled satisfactorily, regardless of the color space used. In general, however, images with 16-fold reduction in the amount of chrominance information (that is, a factor of 4 in each spatial direction) are still satisfactory in appearance.

Color↗

Pulmonary nodule mimicked by ECG lead artifact.

Recently, a new ECG lead has been introduced that can mimic a pulmonary nodule to the uninitiated. Alternatively, in those institutions where the lead is commonly seen, physicians may dismiss a real finding on the chest x-ray film as a lead "artifact." We describe the appearance of this new chest wall artifact.

Aged↗

Artifact, bias, and complexity of assessment: the ABCs of reliability.

Interobserver agreement (also referred to here as "reliability") is influenced by diverse sources of artifact, bias, and complexity of the assessment procedures. The literature on reliability assessment frequently has focused on the different methods of computing reliability and the circumstances under which these methods are appropriate. Yet, the credence accorded estimates of interobserver agreement, computed by any method, presupposes eliminating sources of bias that can spuriously affect agreement. The present paper reviews evidence pertaining to various sources of artifact and bias, as well as characteristics of assessment that influence interpretation of interobserver agreement. These include reactivity of reliability assessment, observer drift, complexity of response codes and behavioral observations, observer expectancies and feedback, and others. Recommendations are provided for eliminating or minimizing the influence of these factors from interobserver agreement.

Journal Article↗

Artifacts caused by cosmetics in MR imaging of the head.

Cosmetics can produce severe distortion of the orbital contents in MR imaging. This distortion, typical of compounds that exhibit a permanent magnetic moment, results from iron oxide in the pigments used to produce dark shades of makeup. In general, the artifact created by cosmetics does not interfere with interpreting routine head scans. However, if the orbital contents are the subject of clinical concern, the images may then be rendered nondiagnostic. The artifact created by the makeup is propagated along the frequency-encoding axis of the images.

Cosmetics↗

Pseudoatrophy of the cervical portion of the spinal cord on MR images: a manifestation of the truncation artifact?

Routine evaluation of axial MR images of the cervical spine with high-intensity CSF (long TR/TE spin-echo or gradient-echo images) revealed apparent narrowing of the cord's anteroposterior diameter when these images were compared with corresponding postmyelography CT scans. This discrepancy was believed to be due to the truncation artifact at the CSF-cord boundary. To examine the truncation effect, we compared cord diameters in 12 patients on postmyelography CT scans and MR images and then compared these with MR scans of normal volunteers and of an agar-saline spine phantom. There was an artifactual diminution of the cord diameter in the 128-step phase-encoding axis of the 128 x 256-matrix MR scan as compared with the diameter of the cord in the patients' postiohexol CT scans and in the 256 phase-encoded axis MR scan in the volunteer study. A similar discrepancy was noted in the spine phantom study, in which the cord diameter in the 256-step phase-encoded MR scan, the CT scan, and direct measurement exceeded that in the 128-step phase-encoded axis MR scan. The range of differences between the measurements was as large as 2.3 mm (patients), 1.7 mm (volunteers), and 1.8 mm (phantom) for the three studies. In all three studies, varying the photographic window width and level produced variation in the apparent cord diameter of up to 1.5 mm. To eliminate this effect, the cord diameters in the phantom and the normal control subjects were measured at identical window levels. The truncation artifact, coupled with standard window settings used in photography, may lead to inaccurate display of the diameter of the cervical spinal cord.

Atrophy↗

Anatomic variants and artifacts in ERCP interpretation.

ERCP is a complex diagnostic procedure requiring manual dexterity, careful attention to endoscopic and radiographic technique, and correct interpretation of the resulting images. Not surprisingly, the procedure is associated with many potential pitfalls. Many of these are related to normal anatomic pancreatic and biliary variants and to artifacts associated with the examination itself. Knowledge of these variants and artifacts is necessary to perform procedures and interpret the results effectively. Our discussion and illustrations are based on a retrospective review of approximately 1300 ERCP studies performed at a single center during a 2-year period.

Biliary Tract↗

Artifacts in computed radiography.

Storage-phosphor digital radiographic systems are becoming widely used in a variety of diagnostic procedures. The equipment is reliable and produces images of consistently high quality. However, the images may contain artifacts directly related to the digital techniques used, to the phosphor imaging plate, or to radiography in general. This article illustrates many of the artifacts encountered that are specific to computed radiography, some of which can simulate pathologic lesions. Their causes and remedies are discussed briefly.

Algorithms↗

An ultrastructural study of fixation artifacts in lens epithelium.

The conditions providing for optimal preservation of the ultrastructure of the lens epithelium of embryonic and young chicks were sought, especially with regard to avoiding fixation artifacts and to enhancing the lens cytoskeleton. The optimal fixative/buffer solution for these purposes was found to consist of 2% glutaraldehyde in 0.05M phosphate buffer containing 0.2% tannic acid and 0.002% CaCl2, pH 7.2, whose total osmolarity is about 340 mOsm, and postfixation in 1% osmium. As the osmolarity was increased by use of 0.075M or 0.1M phosphate buffer, intercellular spaces and myelin-like figures appeared along the cell membranes of the epithelial cells and superficial cortical fibers. As the osmolarity was decreased, using 0.02M phosphate buffer, plasma membranes became flaccid and interrupted, nuclei underwent severe shape changes, and the cytoplasm became electron-lucent. Delays of 30 minutes or one hour before fixation caused swelling of cytoplasmic organelles and the nuclear envelope. Primary fixation in osmium resulted in interrupted cell membranes and in swollen organelles. Many of these artifacts seen in the superficial chick lens, produced merely by manipulating the tonicity or the time of fixation after death, have been previously attributed in the literature to cataractous or aging changes. Based on the present findings caution in interpreting electron micrographs of pathologic changes in lens is urged.

Animals↗

Electron microscopic features of never-worn soft contact lenses: deposits or artifacts?

Since scanning electron microscopy (SEM) is commonly used to evaluate hydrophilic lens deposits, it is important to know what artifacts are induced by the various techniques used to process the lenses. We performed scanning electron microscopy (SEM) using never-worn lenses with hydrations from 38.6% to 71%. Each lens was taken from its vial of factory-sealed, sterile-preserved saline and processed for SEM examination using liquid CO2, freon critical point drying, or air drying with or without alcohol dehydration. The lenses revealed abnormal surface structures occasionally resembling deposits reported on worn soft contact lenses. Varying degrees of gas pockets and surface wrinkling were seen. Individual polymers and lens hydration reacted differently to the various techniques of processing. Of the four methods evaluated, air drying without alcohol dehydration induced the least artifacts.

Contact Lenses, Hydrophilic↗

An artifact of liquid emulsion autoradiography.

The localization of 3H-opiates in the myenteric plexus of the guinea pig ileum is subject to systematic artifact when stretch preparations of the myenteric plexus are dipped into liquid Kodak NTB-3 emulsion for autoradiography. The cause of the artifact was determined to be a discontinuous distribution, or retraction, of emulsion over plexuses. The apposition of frozen freeze-dried ileal sections to dried photographic emulsion avoids this source of error.

Animals↗

Limiting artifact in CT stereotaxic periventricular procedures. Technical note.

One potential source of computerized tomography image artifact during stereotaxic data acquisition is scatter from standard steel-tipped fixation pins as supplied for use with the Brown-Roberts-Wells stereotaxic headframe. In some cases, this can hinder selection of periventricular targets. Replacement of the steel-tipped pins with aluminum-tipped pins, which produce less artifact, helps to facilitate stereotaxic intervention.

Aluminum↗

Magnetic resonance imaging and aneurysm clips. Magnetic properties and image artifacts.

The magnetic properties of 12 different types of aneurysm clip were investigated in order to identify which clips allow postoperative magnetic resonance (MR) imaging without risk. Clip-induced MR artifacts were also quantitatively studied using a geometrical phantom. Nonferromagnetic aneurysm clips like the Yaşargil Phynox, Sugita Elgiloy, and Vari-Angle McFadden clips do not appear to contraindicate MR studies performed with a FONAR beta-3000M imager. There is no clip movement upon introduction of the phantom into the MR imager, and the image artifacts caused by the clips are so limited that patients harboring such clips may well be considered for MR imaging. This examination may reveal information not obtainable by any other radiological modality.

Aneurysm↗