Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Surgical Instruments”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67Linked to original sources

[The otolaryngologist and Creutzfeldt-Jakob disease].

Is the ENT surgeon guilty of being a vector in Creutzfeldt-Jakob disease (CJD) in the past, present and future, with possible medico-legal implications, by virtue of his use of biomaterials and of his failure to sterilise surgical instruments adequately? Once the disease has been diagnosed, are there any implications for ENT? CJD is the most frequent clinical manifestation of the infectious subacute spongiform encephalopathies. It is invariably fatal within a few months, and at present there is no known treatment. Currently the diagnosis can be confirmed only by brain biopsy, but diagnostic tests are being developed. The causative agent belongs to the group of non-conventional transmissible agents, or prions, which are resistant to all conventional sterilisation methods. The illness has a long incubation period extending to several years, during which the abnormal prion protein (PPr), derived from a protein which is normally present, accumulates in the central nervous system. CJD is a rare condition, affecting less than one in a million of the population, and manifests itself in one of three distinct ways: sporadic, in 90% of cases, possibly due to a natural mutation of the gene responsible for formation of the protein, hereditary familial (5 to 10% of cases); and iatrogenic, transmitted by the implantation of biomaterials of human origin, which are the cases for which the ENT surgeon could be responsible, and which may affect any age group. The possible modes of ENT transmission have been identified. These could be the use of surgical material contaminated by a patient suffering from CJD, the use of human biomaterials whether dural homografts, ossicular homografts taken together with the donor dura, the use of blood products, or the use of biomaterials of bovine origin. Such materials have been used widely in the past without any observed increase in new CJD cases, but the incubation period of this disease is not well understood. A knowledge of the possible alternatives and of the new relations on the subject should allow us to improve the epidemiology of the condition, help the surgeon in his choice of materials, help in the diagnosis of the condition, and in avoiding its transmission by heeding new advice on sterilisation.

Creutzfeldt-Jakob Syndrome↗

[Laser therapy of the lung: biophysical background].

The laser is a well established surgical instrument in lung therapy. This report provides information on the biophysical basics of the laser-induced thermotherapy (LITT) of lung metastases. Optical properties like absorption and scattering determine the penetration depth of laser radiation in tissue. These parameters vary dynamically during the application and define in combination with thermal tissue properties the achievable destruction volume. Parenchyma behaves very differently compared to more dense tissues due to local inhomogenities and the large amount cavaties filled with air. Beside an account of the affecting parameters an overview of therapy options is given. Therapeutic results depend not only on the tissue properties but also on the technical equipment, e.g. the applicator design and the energy applied. Complex dosimetric models allow for a calculation of the lesion's size in advance.

Animals↗

Endoscopic management of 108 sinus mucoceles.

OBJECTIVES/BACKGROUND: Traditional teaching has emphasized the need for complete removal of sinus mucoceles to achieve a cure. However, with the introduction of endoscopic sinus surgical instruments and techniques, there has been a trend toward transnasal endoscopic management of sinus mucoceles. The aim of this study is to establish the efficacy of endoscopic management of sinus mucoceles. STUDY DESIGN: Retrospective review. PATIENTS AND METHODS: Between 1988 and 2000, 103 patients with 108 paranasal sinus mucoceles were treated endoscopically. This series includes 66 frontal and frontoethmoid, 17 ethmoid, 7 sphenoethmoid, 12 sphenoid, and 6 maxillary mucoceles. Ninety patients (83.3%) had intraorbital extension and 85 of them presented with some degree of proptosis or eye displacement. Sixty patients (55.5%) had erosion of the skull base with varying degrees of intracranial extension of the mucocele. Follow- up ranged from 1 to 131/2 years with a median of 4.6 years. INTERVENTION: All patients underwent endoscopic-wide marsupialization of the mucocele cavity. Stents were used in frontal mucoceles only. RESULTS: Recurrence of a frontal mucocele was seen in 1 patient (0.9%). In 5 patients, out of 23 patients who presented with massive pansinus polyposis in addition to the mucocele, recurrent polyposis required revision surgery. However, the mucoceles did not recur in those patients. CONCLUSIONS: There is increasing evidence in the literature that endoscopic management of sinus mucoceles results in long-term control with recurrence rates at or close to 0%. Rhinologic surgeons should consider the endoscopic technique as the surgical treatment of choice.

Adolescent↗

Efficacy of PdB in preventing intraoperative risk of infectious diseases.

The objectives of this study were to (1) determine the number of punctures surgeons and assistants suffer during operations involving a laparotomy during the intraabdominal and closure phases; and (2) determine if the number of puncture injuries during wound closure can be reduced using a new surgical instrument (PdB) that protects the surgeon's hands and the patient's viscera against needlesticks. For the first objective, all laparotomies performed during 1 month (n = 52) were controlled, collecting the gloves used and determining the number of perforations. For the second objective, a randomized prospective controlled study, involving two series of 100 medial laparotomies, was carried out. The incidence of perforations was 29% during the intraabdominal phase and 16% during the wound closure phase. The glove perforation rate while closing medial laparotomies was 31.5% if the PdB was not used and 3% if the PdB was used (p < 0.0001). The glove perforation rate during laparotomy is significant, but with the use of the PdB this incidence can be significantly reduced.

Abdominal Muscles↗

Effects of core body temperature on changes in spinal somatosensory-evoked potential in acute spinal cord compression injury: an experimental study in the rat.

STUDY DESIGN: Acute spinal cord injury was induced by a clip compression model in rats to approximate spinal cord injury encountered in spinal surgery. Spinal somatosensory-evoked potential neuromonitoring was used to study the electrophysiologic change. OBJECTIVES: To compare and correlate changes in evoked potential after acute compression at different core temperatures with postoperative neurologic function and histologic change, to evaluate current intraoperative neuromonitoring warning criteria for neural damage, and to confirm the protective effect of hypothermia in acute spinal cord compression injury by electrophysiologic, histologic, and clinical observation. SUMMARY OF BACKGROUND DATA: With the increase in aggressive correction of spinal deformities, and the invasiveness of surgical instruments, the incidence of neurologic complication appears to have increased despite the availability of sensitive intraoperative neuromonitoring techniques designed to alert surgeons to impending neural damage. Many reasons have been given for the frequent failures of neuromonitoring, but the influence of temperature-a very important and frequently encountered factor-on evoked potential has not been well documented. Specifically, decrease in amplitude and elongation of latency seem not to have been sufficiently taken into account when intraoperative neuromonitoring levels were interpreted and when acceptable intraoperative warning criteria were determined. METHODS: Experimental acute spinal cord injury was induced in rats by clip compression for two different intervals and at three different core temperatures. Spinal somatosensory-evoked potential, elicited by stimulating the median nerve and recorded from the cervical interspinous C2-C3, was monitored immediately before and after compression, and at 15-minute intervals for 1 hour. RESULTS: Spinal somatosensory-evoked potential change is almost parallel to temperature-based amplitude reduction and latency elongation. Significant neurologic damage induced by acute compression of the cervical spinal cord produced a degree of effect on the amplitude of spinal somatosensory-evoked potential in normothermic conditions that differed from the effect in moderately hypothermic conditions. Using the same electromonitoring criteria,moderately hypothermic groups showed a significantly higher false-negative rate statistically (35%) than normothermic groups (10%). CONCLUSIONS: Systemic cooling may protect against the detrimental effects of aggressive spinal surgical procedures. There is still not enough published information available to establish statistically and ethically acceptable intraoperative neuromonitoring warning and intervention criteria conclusively. Therefore, an urgent need exists for further investigation. Although a reduction of more than 50% in evoked potential still seems acceptable as an indicator of impending neural function loss, maintenance of more than 50% of baseline evoked potential is no guarantee of normal postoperative neural function, especially at lower than normal temperatures.

Acute Disease↗

Evaluation of disinfection and sterilization of reusable angioscopes with the duck hepatitis B model.

PURPOSE: Nosocomial transmission of viral hepatitis and retrovirus infection has been reported. The expected risk is greatest for the hepatitis B virus (HBV). The duck HBV (DHBV) has similar biologic and structural characteristics to HBV and has been adopted as a suitable model for disinfectant testing. METHODS: Angioscopic examination of the external jugular vein was performed on DHBV-infected ducks. After use, the instrument was air dried for 3 minutes. Samples were obtained by flushing the channel with 5 mL of phosphate buffered saline solution. The samples were collected immediately after drying (control), after flushing with 5 mL of water, after glutaraldehyde disinfection for 5, 10, and 20 minutes, and after ethylene oxide gas sterilization. Angioscopes were either precleaned or uncleaned before disinfection/sterilization. Residual infectivity was assessed with inoculation of samples into the peritoneal cavity of day-old ducks (n = 231). RESULTS: DNA analysis results of liver samples showed that all 38 control ducks became infected. The frequency of DHBV infection was reduced to 93% (14 of 15) by flushing the angioscope with 5 mL of sterile water. No transmission occurred after the use of any of the properly precleaned and disinfected/sterilized angioscopes. However, after the use of the uncleaned angioscopes, the transmission rate was 90% (9 of 10) and 70% (7 of 10) after 5 and 10 minutes of contact time, respectively, in 2% glutaraldehyde. Even after the recommended 20 minutes of contact time, there was still 6% (2 of 35) transmission. After ethylene oxide sterilization, two of the recipient ducklings (2 of 35) were infected with DHBV. CONCLUSION: There was no disease transmission after reuse of disposable angioscopes adequately cleaned before disinfection or sterilization. However, if the angioscopes are inadequately cleaned, DHBV can survive despite glutaraldehyde disinfection or ethylene oxide sterilization. This contrasts with previous in vitro and in vivo data with solid surgical instruments. It is postulated that the presence of a narrow lumen or residual protein shielding within the lumen may compromise effective inactivation of hepadnaviruses on angioscopes, with the potential risk for patient-to-patient transmission.

Angioscopes↗

Viscogonioplasty: an effective procedure for lowering intraocular pressure in primary angle closure glaucoma.

PURPOSE: To evaluate the safety and intraocular pressure (IOP) lowering effect of combined phacoemulsification and viscogonioplasty (Phaco-VGP) in managing primary acute closed-angle glaucoma (ACAG) unresponsive to conventional therapy (patent PI). PATIENT AND METHODS: In all, 15 consecutive eyes of patients with refractory ACAG and greater than 270 degrees peripheral anterior synechiae (PAS) underwent VGP. The technique of VGP involved routine phacoemulsification with intraocular lens implantation (Phaco/IOL) under topical anaesthetic. Following IOL implantation a heavy viscoelastic was used to deepen the anterior chamber and then injected near the angle for 360 degrees (without touching the trabecular meshwork) to break the PAS. No surgical instrument was used to physically break the PAS. Upon completion of VGP, automated irrigation with balanced salt solution to remove the viscoelastic was performed. RESULTS: Mean IOP reduced from 52.1 to 14.1 mmHg by Phaco-VGP at 6-months review. 14/15 patients were free of glaucoma medications at 6-month review. All angles showed exposure of the trabecular meshwork over 360 degrees postoperatively without evidence of residual synechiae. No untoward complications were observed in any patient. CONCLUSION: VGP may have a role in controlling IOP effectively and safely in patients with refractory ACAG. It produces a large drop in the IOP and opening of the angle. It is a relatively simple technique to learn and we would recommend its use in the eyes of all patients who have had ACAG and are undergoing cataract extraction.

Acute Disease↗

Coronary pressure-function and steady-state pressure-flow relations during autoregulation in the unanesthetized dog.

The present study was intended to define the interrelation among endocardial flow, endocardial function, and coronary arterial pressure during spontaneous autoregulation in the left ventricle of chronically instrumented unanesthetized dogs. Steady-state sonomicrometric measurements of regional function and epicardial coronary artery pressure were used to determine the lower pressure limit of endocardial autoregulation while global indexes of myocardial demand remained constant. Transmural wall thickening in the circumflex bed remained unchanged (+/- 5% of control values) until coronary pressure fell below 39 +/- 5.6 (SD) mm Hg. Endocardial segment shortening was similarly constant until coronary pressure fell below 42 +/- 7.4 mm Hg. There was no significant change in endocardial flow as coronary pressure was reduced over the autoregulatory plateau from 84 to 49 mm Hg (1.05-0.99 ml/min/g, p = NS). Below the critical pressure limits, small additional reductions in pressure were associated with marked reductions in both endocardial flow and function. The coronary pressure-function relation was linear as well as steep in this range for both wall thickening (r = 0.94 +/- 0.05) and segment shortening (r = 0.96 +/- 0.03). Although the relation between endocardial flow and function showed more variability than pressure-function relations at low pressures, wall thickening reductions and endocardial flow reductions related on a nearly one-to-one basis. The present study establishes that the coronary pressure-function relation can be used to define the lower limit of endocardial autoregulation. It also indicates that the lower pressure limit of endocardial autoregulation is considerably less than in anesthetized animals (40 vs. 70 mm Hg) and that steady-state flow above this limit is controlled more tightly. Although these differences may relate to systemic hemodynamics, it seems likely that general anesthesia and/or acute surgical instrumentation alter coronary autoregulation under at least some experimental circumstances.

Animals↗

Historical evolution of limb amputation.

The amputation of a limb is one of the oldest surgical procedures. In the course of medical history operative techniques and surgical instruments have been improved continuously. As early as the first century Celsus described an amputation. A major step in the development of the operative technique was the introduction of an artery forceps by Paré during the sixteenth century. Nevertheless, due to a lack of analgesics and narcotics the operation had to take only a few minutes. Therefore the amputation was completed in one cut (i.e., detachment of the skin, muscles, and bone at the same level). This technique, known as "classic circular cut," was modified several times in the following period: to reduce suture tension Petit recommended that we transect the skin first and the muscles and bone more proximally ("two-stage circular cut," 1718), and Bromfield approved that the skin be cut first, the muscles more proximally and the bone most proximal ("three-stage circular cut," 1773). Lowdham (1679), Verduyn (1696), and Langenbeck (1810) changed the operative technique in that they used a soft-tissue flap to cover the bone without tension ("flap amputation").

Amputation, Surgical↗

[A new procedure for removal of foreign bodies in the area of the head].

Identification and extraction of penetrating cranial foreign bodies can cause problems in some cases. Small fragments localized deep in the orbit or cerebrum can be especially hard to detect. Severe bleeding and traumatized anatomy can make orientation difficult. We used a new localizing device, computer-assisted surgery (CAS), to good effect in six such cases. CAS is a localizing technique designed to assist the head surgeon during surgery, providing real-time position information. The method is based upon a three-dimensional volume model of the patient's skull generated by preceding computed tomography imaging procedures (CT or MRI). Intraoperative correlation of a 3D-model and the patient's skull allows for real-time position display of a surgical instrument on the monitor screen. Thereby the surgeon is able to localize even small foreign bodies without extensive exploration. In the case of multiple foreign bodies the surgeon calls up a simple documentation facility recording which of the visible fragments have already been extracted. We successfully used the system for extraction of orbital foreign bodies in four and intracerebral foreign bodies in two cases. In a 4-year-old child with gunshot injury the bullet was located in the precentral region and was easily extracted with the CAS system. In a 21-year-old man 39 glass fragments were extracted from the left orbit. In a 36-year-old man a bone fragment was dislocated to the apex of the orbit directly under the optic nerve. Location and extraction were achieved without damage to the orbital structures with the help of the CAS system.

Adult↗

Perioperative contamination in primary total hip arthroplasty.

UNLABELLED: All surgical procedures have the risk of microbial contamination. However, procedures in which prosthetic materials are involved have a high risk for future infectious problems because of the protection offered by the biofilm mode of growth. Studies of perioperative contamination have been done on involved surgical instruments, but whether these instruments transmit contamination to the prosthesis or future site of the prosthesis is not known. The aim of this study was to detect possible bacterial contamination in total hip arthroplasty through instruments that are used at the direct site of implantation during the primary procedure. Samples of the broaches used for preparing the acetabulum and femur, and samples of the reamed acetabular and femoral bone, were collected during 67 consecutive primary total hip arthroplasties in 67 patients. Broach samples were taken at the start and end of every reaming procedure. Four hundred two samples were taken, of which 26 were found to be positive for microorganisms. In 20 patients, at least one of these positive samples had been in direct contact with the actual prosthesis site, indicating that at least 30% of the involved patients had a possible bacterial contamination when leaving the operating theater. LEVEL OF EVIDENCE: Diagnostic study, Level I-1 (testing of previously developed diagnostic criteria in series of consecutive patients--with universally applied reference gold standard). See the Guidelines for Authors for a complete description of levels of evidence.

Arthroplasty, Replacement, Hip↗

[Minimally invasive myocardial bypass surgery using video-assisted thoracoscopy].

PURPOSE: In order to associate the major benefits of the coronary artery bypass graft (CABG) with a less aggressive procedure minimally invasive coronary artery bypass graft (MICABG) has been utilized. The aim of the work is to report our initial experience with this technical approach, using video assisted thoracic surgery (VATS) to facilitate the operation. METHODS: Twenty-six patients, 19 males with ages from 44 to 83 years old, and having isolated lesion of the anterior descending artery were operated upon. Left anterior minithoracotomy of 8-10 cm was performed at the fourth intercostal space. Through this incision the optical device for VATS as well as the surgical instruments were placed in order to provide the complete left internal mammary artery (LIMA) dissection. Bypass circulation was not used and cardiac rate was decreased with the use of intravenous betablockers. For LIMA--anterior descending artery anastomosis, proximal and distal tourniquets were used and 1.5 mg/kg of heparin was intravenously administered. RESULTS: All patients presented satisfactory postoperative evolution, being discharged from the hospital at 72 h after surgery in the majority of the cases. There were delay in two patients healing of incisions and 25 patients have remained asymptomatic, with a mean in postoperative follow-up of four months. One patient died in the second postoperative month due to stroke. CONCLUSION: MICABG makes the surgery possible with better esthetic effect, lower cost and enables faster recovery than the conventional one. The use of VATS through the thoracotomy itself, allows the LIMA dissection without other incisions. It also permitted more ample dissection of the LIMA when compared to minithoracotomy without VATS.

Adult↗

3D-visualization improves the dry-lab coronary anastomoses using the Zeus robotic system.

BACKGROUND: Robotic surgical instruments enable quick and precise movements and may allow complete endoscopic coronary artery bypass grafting. However, cardiac surgeons will have to become familiar with this technology and endoscopic viewing. We present our training program with special focus on 2D- and 3D-visualization. METHODS: A thoracic skeleton, covered with a neoprene suit, served as model for the chest wall. Either a glove, fixed on a metal plate, or a pig heart were placed inside for training. On the glove, a suture line consisting of two lines of 16 points each, with a distance of 2 mm between each point, was stamped. On the pig heart, the LAD was prepared and incised; subsequently an anastomosis was done using the dissected right coronary artery as a graft. The time required was measured for both models. For suturing, the Zeus System (Computer Motion, Goleta, CA) was used and the third robotic arm positioned the endoscopic camera. The scopes were connected to a 3D-camera and the picture was displayed on a headset with two integrated monitors. Visualization was set to either 2D or 3D. Three surgeons were involved in the study. Each one did at least 12 anastomoses on 2D and 3D. RESULTS: The three surgeons involved showed a clear and rapid learning curve. The times required for the suture line decreased from 12.5 +/- 1.6 to 8.5 +/- 0.5 minutes with 2D and from 11.9 +/- 5.4 to 7.8 +/- 0.5 minutes for 3D respectively. This decrease did reach statistical significance (p = 0.03). In the pig heart model, the anastomosis times decreased from 33.2 +/- 8.4 to 15.7 +/- 0.3 minutes with 3D-visualization, and from 36.2 +/- 2.2 to 29.5 +/- 3.3 minutes with 2D. The decrease in anastomosis time did again reach significance (p = 0.025). At the end of the study, the times achieved with 2D-visualization were significantly longer than those with 3D (p = 0.01). CONCLUSIONS: A surgical training program is mandatory to become familiar with these new technologies. Both models showed learning curves over an acceptable time course. 3D-visualization facilitated quick and precise movements, thus resulting in shorter anastomosis times.

Anastomosis, Surgical↗

Minimal access aortic valve surgery.

OBJECTIVE: We report our experience with minimal access aortic valve surgery and discuss the three approaches used. METHODS: From June 1996 to October 1997, 18 patients underwent minimally invasive aortic valve surgery through three different incisions: right parasternal minithoracotomy (three cases), upper ministernotomy (11 cases), and transverse sternotomy (four cases). No special surgical instrumentation was used. Aortic valve replacement was carried out in 17 patients and aortic valve repair in one patient. The patients ranged in age from 42 to 86 years (mean 64 years). Concomitant procedures involving the aortic root and the ascending aorta were performed in five patients. RESULTS: There was no mortality and no complications related to the procedure or the access. There was no instability or paradoxical movement of the chest wall. One patient was reoperated for postoperative bleeding. All patients were discharged from hospital within the usual time. No attempts were made to discharge them earlier, even if they recovered quickly. CONCLUSIONS: Of the three incisions used, the upper ministernotomy seemed to be the safest and easiest to perform. Through this incision, both the aorta and the right atrium could be cannulated, the right ventricle was accessible, and concomitant procedures on the ascending aorta could be carried out. The drawback of minimal access aortic valve surgery in general is that it is difficult to de-air the heart and more difficult to master intra- and postoperative complications should they occur.

Adult↗

Measurements and modelling of the compliance of human and porcine organs.

Stress-strain data obtained from animal and human tissue have several applications including medical diagnosis, assisting in surgical instrument design and the production of realistic computer-based simulators for training in minimal access surgery. Such data may also be useful for corroborating mathematical models of tissue response. This paper presents data obtained from ex-vivo and in-vivo tissue indentation tests using a small indentor that is similar to instruments used in minimal access surgery. In addition, uniform stress tests provide basic material property data, via an exponential stress-strain law, to allow a finite element method to be used to predict the response for the non-uniform stresses produced by the small indentor. Data are obtained from harvested pig liver and spleen using a static compliance probe. Data for human liver are obtained from volunteer patients, undergoing minor open surgery, using a sterile hand-held compliance probe. All the results demonstrate highly non-linear stress-strain behaviour. Pig spleen is shown to be much more compliant than pig liver with mean elastic moduli of 0.11 and 4.0 MPa respectively. The right lobe of human liver had a mean elastic modulus of about 0.27 MPa. However, a single case of a diseased liver had a mean modulus of 0.74 MPa--nearly three times the stiffness. It was found that an exponential stress-strain law could accurately fit uniform stress test data and that subsequent finite element modelling for non-uniform stress around a small indentor matched measured force characteristics.

Animals↗

[Tactile sensor for tissue differentiation in minimally invasive ENT surgery].

BACKGROUND: In endoscopic surgery, stereoscopic vision and tactile information about tissue consistency are no longer available to the surgeon. METHODS: To compensate for these sensory deficits, various tissues can be characterized with an electromechanical sensor that records their resonance frequencies. In the future, the sensor will be integrated into surgical instruments, providing the surgeon with information about tactile properties of the tissue. We determined the impedance of tissues removed interoperatively (nasal polyps, lymph nodes, cartilage, bone) and different bony structures in a skull specimen. The examinations were carried out with an experimental setup and subsequently with a prototype of the tactile sensor. RESULTS: Resonance frequency increased with tissue hardness. Measurements with the experimental setup showed resonance frequencies for soft tissues between 15 and 30 Hz. We found that the bony septa of the ethmoid have a resonance frequency of 240-320 Hz and the thicker bony structures at the frontal skull base have a frequency of 780-930 Hz. Measurements of tumors in the upper aerodigestive tract showed that it is possible to differentiate between healthy mucosa, carcinomateous infiltrated mucosa, and carcinomateous undermined mucosa. In case of undermining tumor, the resonance frequency was one third higher than healthy mucosa. These results obtained with the experimental setup were reproduced with the tactile sensor prototype. CONCLUSIONS: The use of tactile information in endoscopic otolaryngological surgery may improve intraoperative tissue differentiation in the future. The safety of minimal invasive operations in head and neck surgery can be increased.

Endoscopes↗

Minimally invasive transforaminal lumbar interbody fusion (TLIF): technical feasibility and initial results.

Forty-nine patients underwent minimally invasive transforaminal lumbar interbody fusion (TLIF) from October 2001 to August 2002 (minimum 18-month follow-up). The diagnosis was degenerative disc disease with herniated nucleus pulposus (HNP) in 26, spondylolisthesis in 22, and a Chance-type seatbelt fracture in 1. The majority of cases (n = 45) were at L4-L5 or L5-S1. A paramedian, muscle-sparing approach was performed through a tubular retractor docked unilaterally on the facet joint. A total facetectomy was then conducted, exposing the disc space. Discectomy and endplate preparation were completed through the tube using customized surgical instruments. Structural support was achieved with allograft bone or interbody cages. Bone grafting was done with local autologous or allograft bone, augmented with recombinant human bone morphogenetic protein-2 in some cases. Bilateral percutaneous pedicle screw-rod placement was accomplished with the Sextant system. There were no conversions to open surgery. Operative time averaged 240 minutes. Estimated blood loss averaged 140 mL. Mean length of hospital stay was 1.9 days. All patients presenting with preoperative radiculopathy (n = 45) had resolution of symptoms postoperatively. Complications included two instances of screw malposition requiring screw repositioning and two cases of new radiculopathy postoperatively (one from graft dislodgement, the other from contralateral neuroforaminal stenosis). Narcotic use was discontinued 2-4 weeks postoperatively. Improvements in average Visual Analogue Pain Scale and Oswestry Disability Index (preoperative to last follow-up) scores were 7.2-2.1 and 46-14, respectively. At last follow-up, all patients had solid fusions by radiographic criteria. Results of this study indicate that minimally invasive TLIF is feasible and offers several potential advantages over traditional open techniques.

Adult↗

[Recent advances and problems in peripheral arterial reconstruction].

Recent advances in the field of peripheral arterial reconstruction have been remarkable. These advances are mainly derived from the development of diagnostic technology such as Doppler ultrasound analysis, further refinement of surgical technique including surgical instruments and materials, and naturally improvement of patient care in the pre-, peri- and postoperative period. During the past 14 years we have performed peripheral arterial reconstruction in 1,200 cases (1,660 limbs) mainly with occlusive lesion due to arteriosclerosis obliterans. In our hand, aorto-iliac occlusive lesion has been routinely bypassed with Dacron prostheses and the secondary patency rate at eleven years reached 96.5%. The main problems encountered in this region were anastomotic aneurysm in the femoral artery (3.9%) and graft infection (1.2%). In the infrainguinal region there are still problems to be solved, although the primary (secondary) 5 year patency rates of reversed vein graft as well as in situ vein graft including femoro-popliteal below knee and femoro-crural bypasses have exceeded 70% (85%). First, there is no graft material comparable to the autogenous vein (AVG). Secondly, many of the AVG should suffer occlusive pathological changes from the environment in the long term following surgery. At the present time, we have no effective method to solve these problems, therefore we should follow up the patients heedfully to maintain the graft patency as well as to improve their quality of life and prognosis.

Anastomosis, Surgical↗