Morphometric X-ray absorptiometry in the assessment of vertebral fractures in renal transplant patients.

BACKGROUND: Bone mineral density (BMD) is widely employed to evaluate the risk of fractures, but more than mineral content is bone quality that accounts for bone strength. In fact, occasionally, subjects with normal or only mildly reduced BMD also experience pathologic fractures. In metabolic bone disease, like renal transplantation, the agreement between fractures and BMD is less predictable. We assessed the prevalence of vertebral fractures by means of a new, DEXA-based method (morphometric absorptiometry, MXA) and compared its concordance with the two mostly employed radiological techniques (Visual semi-quantitative, SQ, and morphometric radiography, MRX) in an asymptomatic population of transplanted patients. Moreover, the association of bone fractures with low BMD values was examined. METHODS: Fifty-three renal transplant patients underwent spinal radiographs and BMD measurements by DEXA. In order to obtain a morphometric assessment, a lateral DEXA scan was performed. RESULTS: Patients with vertebral fracture were 17/53 (32%) with both SQ and MRX, and 12/53 (23%) with MXA (chi(2) = n.s.). A single fracture was detected in 9/53 patients (17%) with SQ and MRX, and in 4/53 (7.5%) with MXA; multiple fractures were 8/53 (15%) with any technique. With SQ as the standard reference, predictive indexes were excellent with MRX (invariably 100%) and quite good with MXA (sensitivity 70.6%; specificity 100%). Of the total of 689 vertebrae, 49 were fractured with SQ, 54 with MRX and 41 with MXA. Mild deformities were present in 21 (SQ), 26 (MRX) and 13 (MXA) vertebral bodies, respectively, while moderate-severe deformities were 28 with any technique. Again, with SQ as standard reference, predictive indexes were good (MRX: sensitivity 100%, specificity 99.2%; MXA: sensitivity 83.7%, specificity 100%). When we classified patients according to BMD T-score values, SQ and MRX recognized fractures in 4/18 normal (22%), 10/22 osteopenic (45%) and 3/13 osteoporotic (23%). With MXA 3/18 (17%) normal, 6/22 (27%) osteopenic and 3/13 (23%) osteoporotic were fractured. The lower performance of MXA was very likely due to the poor quality of images from the upper thoracic spine of obese subjects. CONCLUSIONS: Prevalence of vertebral fractures in renal transplant patients is quite high and randomly associated with reduced BMD. A surveillance of the spine by Rx, implemented with vertebral morphometry, is therefore warranted to recognize the disease. (MXA is a reliable alternative technique, especially in more severely affected individuals.) MXA, although less sensitive than the conventional techniques because of possible technical biases, is very specific, and can be proposed for follow-up purposes in this population of patients.

Absorptiometry, Photon↗

[Validation of a rapid urease test for the diagnosis of Helicobacter pylori infection].

OBJECTIVE: Several non-commercial rapid urease tests have been designed with the objective of reducing the cost of Helicobacter Pylori infection diagnosis. The objective of the present prospective trial is to assess one of these tests, using the histologic evaluation for the presence of Helicobacter Pylori, as the standard reference of diagnosing this infection. METHODS: Patients undergoing upper endoscopy for various reasons were prospectively enrolled. Three endoscopic biopsies of the antrum and three from the corpus of the stomach were taken in every patient enrolled. The specimens were evaluated by the rapid urease test on an individual basis, comparing the results with the histology assessment of the Helicobacter Pylori status, which was considered as the standard reference for the diagnosis of the infection. RESULTS: One hundred and four patients were enrolled, of which 94 were eligible. Fifty-five patients (60.43%) were infected with Helicobacter Pylori. The sensibility and specificity of the urease test evaluated at 4 hours was 65.45% and 100% respectively. The evaluation at 24 hours of the sensibility and specificity was 83% and 94% respectively. CONCLUSIONS: The non-commercial rapid urease test is a practical, fast, and cost effective method for the detection of Helicobacter Pylori infection, and its diagnostic utility is similar to the commercial test available.

Adult↗

High-performance tryptic mapping of recombinant bovine somatotropin.

Experiments are described that have lead to the development of a highly reproducible tryptic map of recombinant DNA derived bovine somatotropin (rbSt). Tryptic digestion of rbSt at 37 degrees C results in the formation of a precipitate. Preliminary characterization of the precipitate suggests that its formation is due to the association of intermediate tryptic fragments. An examination of the temperature dependence of the digestion has revealed that precipitate formation is inhibited when digestion is performed at 10 degrees C or less. The combination of a 5-mg sample, the use of highly purified trypsin, and digestion at 5 degrees C generate a tryptic map that exhibits an average 1.3% RSD (0.5-3.6%) for all anticipated fragments. Validation studies demonstrate that while the peak response precision is rugged to daily variation of operators or chromatographic systems, the fragment retention is not. This dictates that peaks be assigned by qualitative pattern recognition. Assay ruggedness in the peak response domain allows for the implementation of quantitative methods for the comparison of rbSt reference standard and sample tryptic maps. The assay is linear for all anticipated fragments within 50-150% of the operating range. Specificity is established by assay of pituitary somatotropins from other species and rbSt analogs produced by site-specific mutagenesis. The data demonstrate that all single amino acid substitutions examined are identified by using the technique. Assay sensitivity is validated for selected tryptic fragments through analysis of reference standard digests spiked with known amounts of rbSt analog digests. The data indicate that potential impurities of 3.2, 2.0, and 4.5% can be quantitated with statistical confidence in the tryptic fragments T1, T10, and T23 + 25, respectively.

Amino Acid Sequence↗

A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts.

BACKGROUND: Early coronary bypass graft failures may be preventable if identified intraoperatively. The purpose of this investigation was to compare the diagnostic accuracy of two intraoperative graft assessment techniques, transit-time ultrasound flow measurement and indocyanine green fluorescent-dye graft angiography. METHODS: Patents undergoing isolated coronary artery bypass grafting with no contraindications for postoperative angiography were enrolled in the study. Patients were randomly assigned to be evaluated with either indocyanine green angiography (Novadaq Spy angiography system; Novadaq Technologies Inc, Concord, Ontario, Canada) and then transit-time ultrasonic flow measurement (Medtronic Medi-Stim Butterfly Flowmeter TTF measurement system; Medtronic Inc, Minneapolis, Minn) or transit-time flow then indocyanine green angiography. Patients underwent x-ray angiography on postoperative day 4. The primary end point of the trial was to determine the sensitivity and specificity of the two techniques versus reference standard x-ray angiography to detect graft occlusion or greater than 50% stenosis in the graft or perianastomotic area. RESULTS: Between February 2004 and March 2005, 106 patients were enrolled and x-ray angiography was performed in 46 patients. In total, 139 grafts were reviewed with all three techniques and 12 grafts (8.2%) were demonstrated to have greater than 50% stenosis or occlusion by the reference standard. The sensitivity and specificity of indocyanine green angiography to detect greater than 50% stenosis or occlusion was 83.3% and 100%, respectively. The sensitivity and specificity of transit-time ultrasonic flow measurement to detect greater than 50% stenosis or occlusion was 25% and 98.4%, respectively. The P value for the overall comparison of sensitivity and specificity between indocyanine green angiography and transit-time flow ultrasonography was .011. The difference between sensitivity for indocyanine green angiography and transit-time flow measurement was 58% with a 95% confidence interval of 30% to 86%, P = .023. CONCLUSION: Indocyanine green angiography provides better diagnostic accuracy for detecting clinically significant graft errors than does transit-time ultrasound flow measurement.

Aged↗

Low-molecular-weight heparin may alter point-of-care assay for international normalized ratio.

STUDY OBJECTIVE: To compare the international normalized ratio (INR) measured by a point-of-care testing device with that measured by a reference laboratory method for patients receiving either warfarin only or warfarin plus low-molecular-weight heparin (LMWH). DESIGN: Retrospective study. SETTING: Outpatient anticoagulation clinic. SUBJECTS: Ninety-one patients receiving warfarin for various indications; 59 of them receiving only warfarin and 32 receiving warfarin plus LMWH. INTERVENTION: Capillary blood was obtained for INR determination by a point-of-care device, and venous blood was obtained for INR determination in a standard reference laboratory. MEASUREMENTS AND MAIN RESULTS: Ninety-one patients had INR pairs run on a point-of-care device and by the laboratory. In both the patients receiving only warfarin and in those receiving warfarin plus LMWH, the mean INR as determined by the point-of-care testing device was statistically significantly higher than the mean INR determined by the laboratory. Although the differences were statistically significant in both groups, the clinical significance of this difference was accentuated in the patients receiving warfarin plus LMWH. The measure of divergence between the point-of-care and laboratory methods was greater in the group receiving warfarin plus LMWH than in the warfarin-only group, with a mean +/- SD percent change between the INR values of 24.19 +/- 27.54% in the warfarin plus LMWH group and 7.21 +/- 17.73% in the warfarin-only group. In assessing the clinical impact of such variability, a greater degree of discordance in dosing adjustment decisions was noted for patients receiving warfarin plus LMWH. In this group, a 25% rate of discordance was noted compared with 8% in the warfarin-only group. Such discrepancy in dosing decisions based on the point-of-care INR would have resulted in discontinuation of LMWH therapy before the patient acquired a true therapeutic INR, with use of the laboratory measurement. CONCLUSION: The INR measured with the point-of-care device in patients receiving concurrent LMWH and warfarin therapy may be inaccurate. Patients receiving LMWH in addition to warfarin should have INRs checked by means of the standard reference laboratory method.

Adult↗

Angioscopic versus angiographic detection of thrombus during coronary interventional procedures.

The purpose of this study was to compare angiography and angioscopy for the detection of thrombus during coronary interventional procedures. The diagnosis of coronary thrombus has important clinical implications. Angioscopy can directly visualize the coronary luminal surface and may be more accurate than angiography in the diagnosis of thrombus. Angiography and angioscopy were sequentially performed in 75 patients undergoing a variety of interventional cardiology procedures during 117 distinct procedural time points. The angiographic presence of thrombus was defined as a noncalcified filling defect outlined on at least 3 sides by contrast media. The angioscopic presence of thrombus was defined as red material protruding into the lumen (intraluminal thrombus) or adherent to the luminal wall (mural thrombus) that persisted despite flushing. Thrombus was detected on 14 occasions (12.0%) by angiography compared with 48 (41.0%) by angioscopy (p < 0.05). In 4 of the 14 episodes (28.6%) of angiographic filling defects, angioscopy found no evidence of thrombus and provided an alternative explanation for the angiographic filling defect. When angioscopy was used as a reference standard, the sensitivity of thrombus detection by angiography was 20.8%, with a specificity of 94.2% and a predictive value of 71.4%. The sensitivity of angiography for the detection of intraluminal (protruding into the lumen) thrombus was 100% compared with only 10% for mural (adherent to the luminal wall) thrombus (p < 0.05). Angioscopy was significantly more accurate than angiography for detecting coronary thrombus and may be considered an improved reference standard for this diagnosis.

Aged↗

Comparison of auscultation with two-dimensional and Doppler echocardiography in patients with suspected mitral valve prolapse.

Auscultation was compared to two-dimensional echocardiography (2D echo) and Doppler ultrasonography in 140 consecutive patients referred for evaluation for suspected mitral valve prolapse (MVP) to asses the precision of the two diagnostic methods. Ninety patients (64%) had midsystolic clicks, of which 42 (47%) had MVP by echocardiography; 6 patients (4%) had MVP by 2D echo but no click on examination. In 15 (17%) of the 90 patients, a click was heard only in the standing or squatting positions and 2D echo did not detect prolapse in the supine position in 10 (67%) of the 15. With auscultation as the reference standard for MVP, 2D echo has a sensitivity of 47% and a specificity of 89%. Of the 140 patients, 51 (36%) had systolic murmurs; Doppler detected mitral and/or tricuspid regurgitation in 26 (50%). In 23 (16%) patients, there was Doppler evidence of mitral or tricuspid regurgitation even though systolic murmurs were not heard. Auscultation shows a 53% sensitivity and 73% specificity for systolic murmurs, using Doppler ultrasonography as the reference standard. Of 48 patients with MVP by 2D echo, 15 (13%) had associated mitral regurgitation by Doppler. The results indicate that 2D echo and Doppler ultrasonography should be interpreted in concert with auscultation for the diagnosis of mitral valve prolapse and for therapeutic decision making.

Adult↗

Effect of milk fractions on survival of equine spermatozoa.

Milk-based semen diluents are known to be practical and effective in protecting equine spermatozoa during storage. Due to complex composition of milk, the components which are beneficial or harmful to spermatozoa are unknown. To address these unknowns the effect of various milk fractions on motility of stallion spermatozoa was evaluated. The fractions tested were native phosphocaseinate (NPPC), beta-casein, whey protein concentrate (WPC), alpha-lactalbumin, beta-lactoglobulin, microfiltrate, and ultrafiltrate. The standard reference diluents were INRA 82, commercial skim milk, and Hank's salts solution supplemented with Hepes, glucose, lactose (HGLL) supplemented with BSA. After 48 and 96 h storage at 4 or 15 degrees C some milk fractions (ultrafiltrate, microfiltrate, and alpha-lactalbumin fraction) decreased spermatozoal survival. Others (beta-lactoglobulin (BL) and native phosphocaseinate) were protective. Native phosphocaseinate (NPPC) at milk concentration afforted better protection than did the standard reference diluents. The optimal concentration of beta-lactoglobulin afforted significantly better protection than did BSA. The protection afforded by native phophocaseinate was not synergistic with beta-lactoglobulin. This implies a similar mechanism of protective action of these two components. Semen diluted in HGLL supplemented with NPPC (HGLL-NPPC) or in INRA 82 and stored 24 h at 15 degrees C or 4 degrees C, respectively, produced no difference of spermatozoal motility. However, fertility of semen stored in HGLL-NPPC (60%) was higher (p < 0.05) than that stored in INRA 82 (36%).

Journal Article↗

Prevalence and deteminants of obesity in Spanish children and young people.

Prevalence estimates of obesity in a national random sample of Spanish children and young people are presented in this paper, defined by age- and sex-specific BMI national reference standards for the 85th percentile (overweight) and 97th percentile (obesity), as well as by Cole et al. criteria. A random sample of 3534 people, aged 2-24 years, was interviewed between 1998 and 2000. The study protocol included personal data, data on education and socioeconomic status (SES) for the family, dietary assessment, anthropometric measurements and physical activity. The prevalence of obesity was 13.9 % (95 % CI 12.7, 15.1) considering Spanish reference standards as cut-offs. Obesity was significantly higher in boys (15.6 %) than in girls (12 %). The highest values were observed between 6 and 13 years of age. Using Cole's cut-offs, the estimated prevalence of obesity was 6.3 % (95 % CI 5.4, 7.5) with a similar pattern to that previously described by sex. Regarding sociodemographic factors, sex, age group, region, size of locality of residence, mother's level of education and family SES level were significant predictors for obesity in children and adolescents under 14 years. Among young people, the main sociodemographic predictors for obesity were geographical region and family SES level. Odds ratio for obesity was 1.27 for those with a more frequent consumption of buns, cakes and snacks, and 1.71 for those with more frequent consumption of sugared drinks. Adequate consumption of fruit and vegetables, usually having breakfast and regular sports practice had a protective effect. The available data show that obesity in Spain is a public health issue given its magnitude and increasing trends. Among Spanish children and young people, those at prepubertal age, particularly boys, can be identified as a group at higher risk for overweight and obesity, particularly children from lower SES families.

Adolescent↗

Incremental value of multiplanar cross-referencing for prostate cancer staging with endorectal MRI.

OBJECTIVE: The purpose of this study was to assess whether use of the PACS cross-referencing tool in 3D MRI improves tumor staging of prostate cancer when pathologic findings are used as the reference standard. MATERIALS AND METHODS: The institutional review board granted a waiver of informed consent for the study. Endorectal MRI at 1.5 T was performed before radical prostatectomy in 255 consecutive patients. Two radiologists unaware of the clinical data retrospectively and independently interpreted MR images without and with cross-referencing to predict the presence of extracapsular extension (ECE) and seminal vesicle invasion (SVI). Histopathologic findings were used as the reference standard. Area under the receiver operating characteristics curve (AUC), sensitivity and specificity, and weighted kappa statistics were calculated. RESULTS: At histologic examination, 68 (27%) of the patients were found to have ECE and 13 (5%) of the patients to have SVI; the latter all had ECE. In detecting ECE, both reviewers had a higher AUC using cross-referencing (p < 0.001 for both). The weighted kappa value was 0.56 for MRI alone and 0.76 for MRI with cross-referencing, indicating fair to good interobserver agreement. Sensitivity and specificity for ECE with MRI alone and with cross-referencing were 43% and 94% and 57% and 100% for reviewer 1 and 40% and 93% and 59% and 98% for reviewer 2, respectively. In detecting SVI, both reviewers had a higher AUC with cross-referencing (p = 0.007 and p = 0.056 for reviewers 1 and 2, respectively). Reviewer 1 benefited much more from cross-referencing than did reviewer 2. The weighted kappa statistic was 0.69 for MRI alone and the same with cross-referencing, indicating good interobserver agreement. Sensitivity and specificity for SVI with MRI alone and with cross-referencing, respectively, were 23% and 83% and 46% and 93% for reviewer 1 and 31% and 91% and 54% and 95% for reviewer 2. CONCLUSION: PACS cross-referencing significantly improves tumor staging of prostate cancer with 3D MRI. Some reviewers benefit more than others from use of this tool.

Adult↗

Optimizing imaging protocols for overweight and obese patients: a lutetium orthosilicate PET/CT study.

UNLABELLED: High photon attenuation and scatter in obese patients affect image quality. The purpose of the current study was to optimize lutetium orthosilicate (LSO) PET image acquisition protocols in patients weighing > or =91 kg (200 lb). METHODS: Twenty-five consecutive patients (16 male and 9 female) weighing > or =91 kg (200 lb; range, 91-168 kg [200-370 lb]) were studied with LSO PET/CT. After intravenous injection of 7.77 MBq (0.21 mCi) of 18F-FDG per kilogram of body weight, PET emission scans were acquired for 7 min/bed position. Single-minute frames were extracted from the 7 min/bed position scans to reconstruct 1-7 min/bed position scans for each patient. Three reviewers independently analyzed all 7 reconstructed whole-body images of each patient. A consensus reading followed in cases of disagreement. Thus, 175 whole-body scans (7 per patient) were analyzed for number of hypermetabolic lesions. A region-of-interest approach was used to obtain a quantitative estimate of image quality. RESULTS: Fifty-nine hypermetabolic lesions identified on 7 min/bed position scans served as the reference standard. Interobserver concordance increased from 64% for 1 min/bed position scans to 70% for 3 min/bed position scans and 78% for 4 min/bed position scans. Concordance rates did not change for longer imaging durations. Region-of-interest analysis revealed that image noise decreased from 21% for 1 min/bed position scans to 14%, 13%, and 11% for, respectively, 4, 5, and 7 min/bed position scans. When compared with the reference standard, 14 lesions (24%) were missed on 1 min/bed position scans but only 2 (3%) on 4 min/bed position scans. Five minute/bed position scans were sufficient to detect all lesions identified on the 7 min/bed position scans. CONCLUSION: Lesion detectability and reader concordance peaked for 5 min/bed position scans, with no further diagnostic gain achieved by lengthening the duration of PET emission scanning. Thus, 5 min/bed position scans are sufficient for optimal lesion detection with LSO PET/CT in obese patients.

Female↗

A comparison of saliva testing to urinalysis in an arrestee population.

Past studies have concluded that individuals under criminal justice supervision often underreport their recent use of illicit drugs. To address this underreporting, objective biological measures, such as urine, saliva, and hair testing, have been used to gain better estimates of illegal drug use. While urinalysis is generally recognized as the reference standard, a method recently introduced in nonlaboratory settings for ascertaining drug use-saliva testing-may offer an alternative to urinalysis. To date, however, no studies have compared saliva testing to urinalysis among criminal justice populations. In the current study, urine and saliva specimens were collected from 114 adult arrestees interviewed as part of Maryland's Substance Abuse Need for Treatment among Arrestees (SANTA) project. With urinalysis as the reference standard, analysis of the saliva test results indicated sensitivity of 100% and specificity of 99% for cocaine and sensitivity of 88% and specificity of 100% for heroin. For marijuana, however, the saliva results indicated a sensitivity of only 5%. Anecdotal reports from the field suggest that saliva may have some advantages over urine because of the ease of collection, invulnerability to adulteration, and minimal personal invasiveness. These findings suggest that a more comprehensive study to evaluate the efficacy of saliva testing in field research may be warranted.

Adult↗

Severe liver fibrosis or cirrhosis: accuracy of US for detection--analysis of 300 cases.

PURPOSE: To determine the accuracy of various ultrasonographic (US) signs for assessment of the degree of liver fibrosis, with histologic results as reference standard. MATERIALS AND METHODS: Three hundred consecutive asymptomatic patients with at least 6 months of increased levels of aspartate aminotransferase and/or alanine aminotransferase underwent liver US and biopsy. The estimated pretest probability of severe fibrosis or cirrhosis was 35%. Three US parameters were investigated: liver surface nodularity, caudate lobe hypertrophy, and pattern of hepatic venous blood flow. US results were compared with histologic results obtained after liver biopsy, which constituted the reference standard for diagnosis of severe fibrosis or cirrhosis. The degree of fibrosis was graded according to METAVIR criteria, with stages 3 and 4 considered together. Data were analyzed with kappa and chi2 statistics. Sensitivity, specificity, positive and negative likelihood ratios, and posttest probability were calculated for each US sign. RESULTS: In 107 (36%) patients with severe fibrosis (n = 34) or cirrhosis (n = 73), liver surface nodularity had the highest diagnostic accuracy, with specificity of 95% and positive and negative likelihood ratios 11.6 and 0.51, respectively. When liver surface nodularity was considered alone, posttest probability of severe fibrosis or cirrhosis increased from 35% to 86%. When caudate lobe hypertrophy and hepatic venous blood flow were also taken into account, posttest probability increased by only 2% (ie, to 88%). CONCLUSION: US determination of liver surface nodularity is an accurate method for identifying the subset of asymptomatic patients with severe liver fibrosis or cirrhosis, which indicates a worse prognosis.

Adolescent↗

Role of imaging in pretreatment evaluation of early invasive cervical cancer: results of the intergroup study American College of Radiology Imaging Network 6651-Gynecologic Oncology Group 183.

PURPOSE: To compare magnetic resonance imaging (MRI) and computed tomography (CT) with each other and to International Federation of Gynecology and Obstetrics (FIGO) clinical staging in the pretreatment evaluation of early invasive cervical cancer, using surgicopathologic findings as the reference standard. PATIENTS AND METHODS: This prospective multicenter clinical study was conducted by the American College of Radiology Imaging Network and the Gynecologic Oncology Group from March 2000 to November 2002; 25 United States health centers enrolled 208 consecutive patients with biopsy-confirmed cervical cancer of FIGO stage > or = IB who were scheduled for surgery based on clinical assessment. Patients underwent FIGO clinical staging, helical CT, and MRI. Surgicopathologic findings constituted the reference standard for statistical analysis. RESULTS: Complete data were available for 172 patients; surgicopathologic findings were consistent with FIGO stages IA to IIA in 76% and stage > or = IIB in 21%. For the detection of advanced stage (> or = IIB), sensitivity was poor for FIGO clinical staging (29%), CT (42%), and MRI (53%); specificity was 99% for FIGO clinical staging, 82% for CT, and 74% for MRI; and negative predictive value was 84% for FIGO clinical staging, 84% for CT, and 85% for MRI. MRI (area under the receiver operating characteristic curve [AUC], 0.88) was significantly better than CT (AUC, 0.73) for detecting cervical tumors (P = .014). For 85% of patients, FIGO clinical staging forms were submitted after MRI and/or CT was performed. CONCLUSION: CT and MRI performed similarly; both had lower staging accuracy than in prior single-institution studies. Accuracy of FIGO clinical staging was higher than previously reported. The temporal data suggest that FIGO clinical staging was influenced by CT and MRI findings.

Adenocarcinoma↗

Noninvasive techniques to detect fetal anemia due to red blood cell alloimmunization: a systematic review.

OBJECTIVE: To estimate, in maternal red blood cell alloimmunization, the diagnostic value of fetal ultrasonography and Doppler blood flow velocity in the evaluation and prediction of fetal anemia. METHODS: Literature from 1970 to 2000 was identified using general bibliographic databases (MEDLINE and EMBASE), the Cochrane Library and relevant specialist register of the Cochrane Collaboration, and by checking reference lists of known primary and review articles. Studies were selected if the accuracy of the fetal ultrasound parameters or Doppler studies of blood flow in the fetal vessels was estimated compared with a reference standard (fetal hemoglobin). The diagnostic tests evaluated were ultrasound measurement of the fetal spleen perimeter and Doppler studies of blood velocity estimates in the umbilical vein, ductus venosus, middle cerebral artery, thoracic aorta, and umbilical vessel combined with the thoracic aorta. Study selection, quality assessment, and data abstraction were performed independently and in duplicate. Data from the selected studies were abstracted as 2 x 2 tables comparing the diagnostic test result with the reference standard. Diagnostic accuracy was expressed as likelihood ratios. RESULTS: The review included eight primary studies with 362 pregnancies affected by red cell alloimmunization. Prospective patient recruitment and complete population details were reported in half of the selected studies (four of eight). Only one study reported masking the diagnostic test results to clinicians. The diagnostic test performance varied widely according to the type of the test evaluated and the cutoff level used to define fetal anemia, which varied from study to study. The diagnostic test study of highest methodological quality reported a positive likelihood ratio of 8.45 (95% confidence interval 4.69, 15.56) and negative likelihood ratio of 0.02 (95% confidence interval 0.001, 0.25) for maximum middle cerebral artery Doppler velocity. CONCLUSION: The literature reporting noninvasive techniques to predict fetal anemia is methodologically poor and a standard approach to the evaluation of these techniques is lacking. A recommendation for practice cannot be generated without further rigorous research.

Blood Flow Velocity↗

Validation of diagnostic imaging based on repeat examinations. An image interpretation model.

PURPOSE: To develop an interpretation model, based on repeatedly acquired images, aimed at improving assessments of technical efficacy and diagnostic accuracy in the detection of small lesions. MATERIAL AND METHODS: A theoretical model is proposed. The studied population consists of subjects that develop focal lesions which increase in size in organs of interest during the study period. The imaging modality produces images that can be re-interpreted with high precision, e.g. conventional radiography, computed tomography, and magnetic resonance imaging. At least four repeat examinations are carried out. RESULTS: The interpretation is performed in four or five steps: 1. Independent readers interpret the examinations chronologically without access to previous or subsequent films. 2. Lesions found on images at the last examination are included in the analysis, with interpretation in consensus. 3. By concurrent back-reading in consensus, the lesions are identified on previous images until they are so small that even in retrospect they are undetectable. The earliest examination at which included lesions appear is recorded, and the lesions are verified by their growth (imaging reference standard). Lesion size and other characteristics may be recorded. 4. Records made at step 1 are corrected to those of steps 2 and 3. False positives are recorded. 5. (Optional) Lesion type is confirmed by another diagnostic test. CONCLUSION: Applied on subjects with progressive disease, the proposed image interpretation model may improve assessments of technical efficacy and diagnostic accuracy in the detection of small focal lesions. The model may provide an accurate imaging reference standard as well as repeated detection rates and false-positive rates for tested imaging modalities. However, potential review bias necessitates a strict protocol.

Diagnostic Imaging↗

Small pulmonary nodules: effect of two computer-aided detection systems on radiologist performance.

PURPOSE: To prospectively compare the effects of two computer-aided detection (CAD) systems on the detection of small pulmonary nodules at multi-detector row computed tomography (CT) by using a consensus panel decision as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Multi-detector row CT scans were randomly chosen and prospectively evaluated in 25 patients. Two dedicated CAD systems-ImageChecker CT (R2 Technologies, Sunnyvale, Calif) and Nodule Enhanced Viewing (NEV) (Siemens Medical Solutions, Forchheim, Germany)-were used. Results were interpreted by three radiologists with 1, 3, and 6 years of experience. Images were evaluated without and with CAD software. The reference standard was assessed by a consensus panel consisting of all three radiologists and an adjudicator with 8 years of experience. RESULTS: A total of 116 pulmonary nodules (average diameter, 3.4 mm; average volume, 32.05 mm3) were found in all data sets during consensus interpretation, which included findings from the CAD software and all radiologists. Overall sensitivity was 73% with ImageChecker CT and 75% with NEV. Overall sensitivity without CAD was 68% for radiologist 1, 78% for radiologist 2, and 82% for radiologist 3. With ImageChecker CT, sensitivity increased to 79% for radiologist 1, 90% for radiologist 2, and 84% for radiologist 3. With NEV, sensitivity increased to 79% for radiologist 1, 90% for radiologist 2, and 86% for radiologist 3. The average number of false-positive findings was six (range, 0-14) with ImageChecker CT and eight (range, 0-22) with NEV. CONCLUSION: Radiologist performance in the interpretation of multi-detector row CT scans can be improved by using CAD systems, with a reduction in the number of false-negative diagnoses. No statistically significant difference in sensitivity was found between the two CAD systems.

Adult↗

Are infrared and thermistor thermometers interchangeable for measuring localized skin temperature?

Localized skin temperature must be measured by accurate and reliable thermometers to effectively evaluate treatment outcomes, monitor changes, and predict potential complications. This study compared localized skin temperature measurements with a contact thermistor thermometer used as a reference standard and a noncontact infrared (IR) skin thermometer to determine their interchangeability with calculated Bland-Altman limits of agreement. Fifty-five adults ages 50 to 89 participated in the study in which data were collected in a climate-controlled room over 3 measurement periods, 1 week apart. The thermistor and IR thermometers were interchangeable with a limit of agreement of +/- 1.5 degrees C. This limit of agreement is acceptable as a reference standard for IR thermometers to measure localized skin temperature in clinical settings.

Aged↗