Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pliability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67Linked to original sources

Functional flexibility of the transketolase molecule.

Transketolase is the simplest representative of the thiamine diphosphate-dependent enzymes. It was the first of these enzymes for which X-ray analysis was performed. Based on the data of X-ray studies and using the mutagenesis technique, the nature of functional groups of the enzyme involved in the interaction with substrates and cofactors and in the coenzyme activation was defined. Thus, considerable achievements have been made in studying the structure of transketolase. However, there is relatively little information on the conformational flexibility of the enzyme molecule while it is functioning, i.e., during its interaction with cofactors and substrates and in the course of intermediate product formation. This review summarizes mainly the results obtained in the author's group, as well as those rare data on this subject that could be found in literature.

Binding Sites↗

Plasticity and slip system of plate-shaped crystals of L-lysine monohydrochloride dihydrate.

PURPOSE: To identify the slip system of L-lysine monohydrochloride dihydrate (LH) and to relate it to the deformation behavior under uniaxial compression. METHODS: The indentation hardness of the [100] face and the indentation moduli of the [100] and [011] faces of plate-shaped single crystals of LH (LHP) were determined using Knoop and Berkovich indenters, respectively. The deformation behavior during uniaxial compression was studied by the punch-stress vs. punch-displacement profile and by electron microscopy of the deformed crystals within cracked compacts. RESULTS: The different indentation (elastic) moduli of the [100] and [011] faces of the crystals are consistent with the molecular packing density along these planes and suggest anisotropy. The existence of the [001] <100> slip system is proposed based on the pattern of changing indentation hardness with varying orientation of the Knoop indenter. A jagged uniaxial compression profile suggests deformation by mechanical twinning and not simple slip. The hypothesis of deformation by mechanical twinning is supported by the appearance of twin bands along the crystal faces as observed by electron microscopy of the cracked compacts. CONCLUSIONS: During compression, most LHP crystals have their [100] faces oriented normal to, or inclined to, the compression axis, thereby facilitating plastic deformation along the [001] <100> slip system by mechanical twinning. Due to the low attachment energy between them, the [001] planes can also act as cleavage planes. This study demonstrates that knowledge of the crystal structure and slip systems can be used to model the tableting and compaction behavior of molecular crystals, such as LH.

Crystallization↗

Actin filament mechanics in the laser trap.

Numerous biological processes, including muscular contraction, depend upon the mechanical properties of actin filaments. One such property is resistance to bending (flexural rigidity, EI). To estimate EI, we attached the ends of fluorescently labelled actin filaments to two microsphere 'handles' captured in independent laser traps. The positions of the traps were manipulated to apply a range of tensions (0-8 pN) to the filaments via the microsphere handles. With increasing filament tension, the displacement of the microspheres was inconsistent with a microsphere-filament system that is rigid. We maintain that this inconsistency is due to the microspheres rotating in the trap and the filaments bending near either attachments to accommodate this rotation. Fitting the experimental data to a simple model of this phenomena, we estimate actin's EI to be approximately 15 x 10(3) pNnm2, a value within the range of previously reported results, albeit using a novel method. These results both: support the idea that actin filaments are more compliant than historically assumed; and, indicate that without appropriately pretensioning the actin filament in similar laser traps, measurements of unitary molecular events (e.g. myosin displacement) may be significantly underestimated.

Actins↗

In vitro performance characteristics of reused ablation catheters.

BACKGROUND: Prior studies have found that there is a widespread practice of catheter reprocessing in cardiac electrophysiology laboratories. Effects of reprocessing of ablation catheters on temperature sensing and mechanical deflection are not fully known. METHODS: Twenty-four new and used ablation catheters were studied. Deviation of temperature sensing by catheters from the temperature of a heated saline bath was measured. The angle of deflection of digitally scanned catheters at 75% and 100% handle deflection was also measured. New and used catheters were compared with respect to their temperature sensing accuracy and deflection characteristics. RESULTS: Overall, there was 0.7 +/- 0.1 degrees C (mean +/- standard error) deviation of the sensed temperature from the bath temperature, with no significant difference between new and used catheters. Similarly, there was no significant difference in the angle of deflection between new (66.7 degrees +/- 6.2 degrees and 24.3 degrees +/- 6.8 degrees at 75% and 100% deflections, respectively) and used (59.6 degrees +/- 5.6 degrees and 28.7 degrees +/- 9.9 degrees at 75% and 100% deflections, respectively) catheters. The difference in the angle of deflection between matched new and used catheters was 18.9 degrees +/- 4.2 degrees and 10.9 degrees +/- 2.4 degrees at 75% and 100% deflections, respectively, with a relatively broad range (5.0 degrees -35.6 degrees and 0.4 degrees -19.0 degrees at 75% and 100% deflections, respectively). CONCLUSIONS: This study found no significant overall difference in temperature sensing accuracy and deflection angle of new and used ablation catheters. Nevertheless, individual differences in deflection characteristics between new and used catheters are occasionally seen and warrant screening of reprocessed catheters prior to their reuse.

Catheter Ablation↗

Backbone dynamics of the cytotoxic ribonuclease alpha-sarcin by 15N NMR relaxation methods.

The cytotoxic ribonuclease alpha-sarcin is a 150-residue protein that inactivates ribosomes by selectively cleaving a single phosphodiester bond in a strictly conserved rRNA loop. In order to gain insights on the molecular basis of its highly specific activity, we have previously determined its solution structure and studied its electrostatics properties. Here, we complement those studies by analysing the backbone dynamics of alpha-sarcin through measurement of longitudinal relaxation rates R1, off resonance rotating frame relaxation rates R1 rho, and the 15N[1H] NOE of the backbone amide 15N nuclei at two different magnetic field strengths (11.7 and 17.6 T). The two sets of relaxation parameters have been analysed in terms of the reduced spectral density mapping formalism, as well as by the model-free approach. alpha-Sarcin behaves as an axial symmetric rotor of the prolate type (D(axially)/D(radially)=1.16 +/- 0.02) which tumbles with a correlation time tau(m) of 7.54 +/- 0.02 ns. The rotational diffusion properties have been also independently evaluated by hydrodynamic calculations and are in good agreement with the experimental results. The analysis of the internal dynamics reveals that alpha-sarcin is composed of a rigid hydrophobic core and some exposed segments which undergo fast (ps to ns) internal motions. Slower motions in the mu s to ms time scale are less abundant and in some cases can be assigned to specific motional processes. All dynamic data are discussed in relation to the role of some particular residues of alpha-sarcin in the process of recognition of its ribosomal target.

Diffusion↗

Light chain of botulinum A neurotoxin expressed as an inclusion body from a synthetic gene is catalytically and functionally active.

Botulinum neurotoxins, the most potent of all toxins, induce lethal neuromuscular paralysis by inhibiting exocytosis at the neuromuscular junction. The light chains (LC) of these dichain neurotoxins are a new class of zinc-endopeptidases that specifically cleave the synaptosomal proteins, SNAP-25, VAMP, or syntaxin at discrete sites. To facilitate the structural and functional characterization of these unique endopeptidases, we constructed a synthetic gene for the LC of the botulinum neurotoxin serotype A (BoNT/A), overexpressed it in Escherichia coli, and purified the gene product from inclusion bodies. Our procedure can provide 1.1 g of the LC from 1 L of culture. The LC product was stable in solution at 4 degrees C for at least 6 months. This rBoNT/A LC was proteolytically active, specifically cleaving the Glu-Arg bond in a 17-residue synthetic peptide of SNAP-25, the reported cleavage site of BoNT/A. Its calculated catalytic efficiency kcat/Km was higher than that reported for the native BoNT/A dichain. Treating the rBoNT/A LC with mercuric compounds completely abolished its activity, most probably by modifying the cysteine-164 residue located in the vicinity of the active site. About 70% activity of the LC was restored by adding Zn2+ to a Zn2+-free, apo-LC preparation. The LC was nontoxic to mice and failed to elicit neutralizing epitope(s) when the animals were vaccinated with this protein. In addition, injecting rBoNT/A LC into sea urchin eggs inhibited exocytosis-dependent plasma membrane resealing. For the first time, results of our study make available a large amount of the biologically active toxin fragment in a soluble and stable form.

Amino Acid Sequence↗

Crystal structure of biphalin sulfate: a multireceptor opioid peptide.

Biphalin is a dimeric opioid peptide, composed of two tetrapeptides connected 'tail-to-tail', that exhibits a high affinity for all three opioid receptor types (i.e. mu, delta and kappa). This study presents the X-ray crystal structure of biphalin sulfate and compares it to other opioids that interact with the same biological targets. Both halves of the molecule have a folded backbone conformation but differ significantly from one another. Residues 1-4 in biphalin, which compare well with the delta selective opioid peptide DADLE, fold into a random coil. Residues 5-8, which can be fit to the mu selective peptide D-TIPP-NH2, exhibit a fairly normal type III' beta bend. Biphalin also exhibits structural similarities with two naltrexone analogs, naltrexonazine and norbinaltorphamine, that are specific to mu and kappa receptor sites.

Binding Sites↗

On the influence of superstructure connection on implant preload: a methodological and clinical study.

In a combined in vitro and in vivo study strain gauges were used to register the deformation in two terminal implant abutment cylinders, when connecting three different prosthetic appliances. The prosthetic constructions were placed on the abutments and fastened in vitro and in vivo by using different torque sequences. Furthermore, in the in vitro situation the three medial abutments were replaced by abutments which were 100 microns shorter. The results show that even if the prosthetic constructions were judged to have a good clinical fit, relatively large External Preloads were registered both in vitro and in vivo. No significant differences in axial force or in bending movement were found between the torque sequences in vivo. There were, however, significant differences in axial force as well as in bending moment in the in vitro experiment. When the shorter medial abutments were used in vitro, a change in the axial force of approximately 200 N was registered. The results confirm that the methodological approach used in this study is valid when evaluating preloads.

Analysis of Variance↗

An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design.

Dental implants are subject to large and highly complex loads of varying magnitude, duration and vector. Bridge performance is closely related to load transmission both at the bone to implant interface and between components within the implant-abutment-bridge cylinder complex. The design of the interface between components within this complex may have a profound influence on the long term function of the implant supported prosthesis. An in vitro evaluation of implants 3.5 mm in diameter, utilizing an internal conical interface has demonstrated increased resistance to bending moments at the fixture-abutment interface (P = 0.00010) and at the abutment-bridge cylinder interface (P < 0.01), when compared to a standard 3.75 mm implant with a hex mediated, butt joint interface. The relatively small values for coefficient of variance measured in both systems would confirm that whilst the size of data is small, it is nonetheless a reliable indication of the relative strength of these implant designs.

Alveolar Process↗

An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses.

In common practice a perfect fit of the prosthetic framework with the implant abutments is almost impossible to achieve. The mismatch, which is principally induced by the technological process adopted to manufacture the fixed prostheses, strains the framework thus generating constraint reactions. These are static forces that load the implant components and the bone at the implant-bone interface and may cause the bone remodelling. Depending on the magnitude of such forces, i.e. depending on the magnitude of the mismatch, the bone remodelling may lead to the loosening of the screws and of the implant-bone interface and hence cause implant failure. The present study shows an in vitro comparison of 3 different connecting abutments (standard, EsthetiCone and CerAdapt, Nobel Biocare AB, Göteborg, Sweden) with relation to the mechanical stresses induced by geometrical mismatches (technology induced errors). Two experimental devices were purposely realized and used to assess the ability of the different abutments to compensate errors. One was designed for translation errors and the other for rotation errors. The experimental apparatus set-up includes 2 freestanding implants supporting a prosthetic structure and the connecting abutments. The implants and the abutments were used as delivered by the manufacturer, while the prostheses were purposely realized and instrumented with strain gauges. The data obtained with the error devices do not give quantitative information on what happens in clinical applications where the implants are connected to living bone, which is a tissue much more deformable than the steel used for the error devices. Results allow direct comparisons of the behaviour of the different investigated abutments with respect to position errors. The CerAdapt system (cement retained ceramic abutments) showed the least strain in presence of translation errors. The standard system (screw retained abutments) showed the least strain in presence of rotation errors.

Biomechanical Phenomena↗

An in vitro evaluation of the strength of a 1-piece and 2-piece conical abutment joint in implant design.

The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. In this in vitro evaluation, implants utilizing an internal conical joint have demonstrated a parity in resistance to bending moments at the fixture-abutment interface, when comparing a 1-piece abutment to a 2-piece abutment, which is tightened via a separate abutment screw, with mean plastic bending moments of 4176 N mm and 4049 N mm respectively. The very small values for coefficient of variance measured in both systems would confirm that whilst the size of data is small it is nonetheless a reliable indication of the relative strength of these conical joint designs.

Dental Abutments↗

Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study.

Since loading is increasingly believed to be a determining factor in the treatment outcome with oral implants, there is a need to expand the knowledge related to the biomechanics of oral implants. The aim of this study is to gain insight in the distribution and magnitude of occlusal forces on oral implants carrying fixed prostheses. This is done by in vivo quantification and qualification of these forces, which implies that not only the magnitude of the load but also its type (axial force or bending moment) will be registered. A total of 13 patients with an implant supported fixed full prosthesis were selected. Occlusal forces on the supporting implants were quantified and qualified during controlled load application of 50 N on several positions along the occlusal surface of the prostheses and during maximal biting in maximal occlusion by use of strain gauged abutments. The test was conducted when the prostheses were supported by all (5 or 6) implants and was repeated when the prostheses were supported by 4 and by 3 implants only. Despite considerable inter-individual variation, clear differences in implant loading between these test conditions were seen. Loading of the extension parts of the prostheses caused a hinging effect which induced considerable compressive forces on the implants closest to the place of load application and lower compressive or tensile forces on other implants. On average, higher forces were observed with a decreasing number of supporting implants. Bending moments were highest when 3 implants only were used.

Adult↗

Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients Part II: An up to 15-years radiographic evaluation.

A total of 123 patients were followed between January 1983 and July 1998 with 140 tooth-implant connected prostheses. The age of the patients at prosthesis installation ranged from 20 to 79 years (mean 51.8). 339 (Brånemark(R) system) implants were connected to 313 teeth. The loading time ranged from 1.5 to 15 years (mean: 6.5). 123 patients were randomly selected as a control group with freestanding implant-supported prostheses only. The age of the patients at prosthesis installation ranged from 22 to 78 years (mean 52.3). The loading time for the 329 freestanding (Brånemark(R) system) implants ranged from 1.3 to 14.5 years (mean: 6.2). Evolution of the marginal bone stability around the implant in the tooth-implant connected as well as the freestanding group was studied with respect to the prognosis of the implants. Over the period from 0 to 15 years, there was significantly more marginal bone loss (0.7 mm) in tooth-implant connected versus freestanding prostheses. No significant difference in marginal bone loss was found between the non-rigid tooth-implant connected prostheses versus freestanding prostheses. However, there was a significant difference in marginal bone loss for rigid and multi-connected tooth-implant connected prostheses versus freestanding ones. The results of this study indicate that more bone is lost around implants which are rigidly connected to teeth. This suggests that bending load, which is increased in tooth-implant connected prostheses, might be responsible for this phenomenon. These observations favor the use of freestanding prostheses whenever possible. However, the clinical significance of greater bone loss in rigid versus non-rigid connections might outweigh the annoying phenomenon of tooth intrusion in the case of non-rigid tooth connection, when connection is considered.

Adult↗

Fatigue resistance of ITI implant-abutment connectors -- a comparison of the standard cone with a novel internally keyed design.

The Straumann Company has recently supplemented its standard 'morse-taper' configuration with an octagonal internal key. During the restorative phase of implant treatment, this additional feature was designed to ensure positional duplicability between the laboratory and the clinical environments. It was, however, unclear whether this keying mechanism would decrease the mechanical strength of the connection between the implant and the abutment. This applies to keyed male and female parts but also to combinations of the new and the standard designs. Specially constructed specimens analogs representing all three combinations were fitted with a T-shaped bar, preangled to 15 degrees and subjected to vertical force applications provided by a servohydrolic fatigue tester. The loading frequency was 2 Hz and the maximum cycle number was 106. The data were evaluated using the staircase technique. The specimens were also modeled and analyzed numerically using finite element procedures. The samples' failure locations were recorded and the displacement vs. cycle number plots were patterned in four groups. The fatigue tests and staircase analysis showed no difference in mechanical resistance between the standard and the internally keyed connectors. The finite element models revealed a stress concentration located at the apical edges of the octagonal connector. However, it appeared that this phenomenon was based on computational rather than mechanical grounds. The locations of the failure sites were distributed randomly across the structures, thereby indicating the absence of a locus of minor resistance. The patterns of the displacement vs. cycle number could not be attributed to specific combinations between the standard and the internally keyed designs. It was concluded that both connectors are equal in their mechanical resistance to bending and torquing forces.

Computer Simulation↗

Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant. A nonlinear finite element stress analysis.

The purpose of this study was to evaluate the mechanical characteristics of the implant-abutment connection of a reduced-diameter ITI dental implant. A finite element model of a slashed circle 3.3 mm x 10 mm ITI solid-screw implant and a 6 degrees solid abutment 4 mm in height was constructed, and the implant-abutment complex was embedded vertically in the center of a slashed circle 1.5 cm x 1.5 cm acrylic cylinder. Static vertical and oblique loads of 300 N were applied in separate load cases. The contact area was defined between the implant-abutment connection and nonlinear finite element stress analysis was performed. The magnitude and distribution of Von Mises stresses and displacement characteristics were evaluated. In vertical loading, Von Mises stresses concentrated around the implant-abutment connection at the stem of the screw and around the implant collar. Oblique loading resulted in a 2-fold increase in stresses at the implant collar, which was close to the yield strength of titanium. Displacement values under both loading conditions were negligible. We conclude that, in a reduced-diameter ITI dental implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. The neck of this implant is a potential zone for fracture when subjected to high bending forces. The reduced-diameter ITI dental implant might benefit from reinforcement of this region.

Biomechanical Phenomena↗

Mandibular flexure and stress build-up in mandibular full-arch fixed prostheses supported by osseointegrated implants.

The biomechanical effect of mandibular functional flexure on stress build-up in implant-supported fixed restorations is discussed. The relative deformations and stress distributions in six different designs of implant-supported prosthetic systems (six or four implants, with or without distal cantilevers, cross-arch or midline-divided bar into two free-standing bridges) were analysed by a three-dimensional finite element (FE) model of a human edentulous mandible. A significant amount of stress in the more distal implants and the superstructure at the symphysis arises as a consequence of mandible functional flexure. The analysis of the stress distributions generated by the different restorative patterns suggests that a division of the superstructure at the level of the symphysis significantly restores the natural functional flexure of the mandible.

Ceramics↗

Effects of aging and cyclic loading on the mechanical properties of glass ionomer cements.

The purpose of this study was to examine the effect of cyclic loading on the flexural strength and fracture toughness of a conventional glass ionomer cement (GIC), a metal containing GIC, hybrid GICs, and, for comparison, a composite. Two sets of specimens were evaluated: a set of controls (at 37 degrees C and 95% humidity) and a set aged for 9 months at 37 degrees C in water. The specimens were tested in static loading in air and water, and cyclic loaded in water. Cyclic loading and aging decreased the flexure strength of all materials significantly. However, wet static fracture toughness did not change on aging, and occasionally increased. Cyclic fracture toughness was lower with all materials except a hybrid glass ionomer without aging. Deterioration in properties was related to relative amount of glass ionomer vs. the resin component. Both flexural strength and fracture toughness of these materials were significantly affected by testing environment, aging and cyclic loading. The lower the resin component of the material, the lower the mechanical properties. The influence of these parameters should be given importance in considering their clinically durability in the oral environment.

Analysis of Variance↗

Flexibility and passive resistance of the hamstrings of young adults using two different static stretching protocols.

This investigation determined the effects of a static stretching program with different stretching protocols on the flexibility and passive resistance of the hamstrings of young adults. Forty healthy subjects (24 males and 16 females) aged 18 to 30 years were randomly assigned to one of four groups. The two training groups underwent static stretch training of the hamstrings either with a four-week protocol or with an eight-week protocol. The other two groups acted as control groups. A significant increase in flexibility of hamstrings was found in both of the two training groups (P<0.05). No difference was found in the range of motion gained between the two training groups. An increase in passive resistance at the corresponding maximal joint angle was only demonstrated in the four-week training group (P<0.05). Both protocols are effective in terms of improving flexibility of hamstrings. However, if injury is reduced when there is relatively lower passive resistance at the end-of-range, then the eight-week training regimen would be recommended.

Adolescent↗