Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MONITORING SYSTEMS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67Linked to original sources

Potential of plant genetic systems for monitoring and screening mutagens.

Plants have too long been ignored as useful screening and monitoring systems of environmental mutagens. However, there are about a dozen reliable, some even unique, plant genetic systems that can increase the scope and effectiveness of chemical and physical mutagen screening and monitoring procedures. Some of these should be included in the Tier II tests. Moreover, plants are the only systems now in use as monitors of genetic effects caused by polluted atmosphere and water and by pesticides. There are several major advantages of the plant test systems which relate to their reproductive nature, easy culture and growth habits that should be considered in mutagen screening and monitoring. In addition to these advantages, the major plant test systems exhibit numerous genetic and chromosome changes for determining the effects of mutagens. Some of these have not yet been detected in other nonmammalian and mammalian test systems, but probably occur in the human organism. Plants have played major roles in various aspects of mutagenesis research, primarily in mutagen screening (detection and verification of mutagenic activity), mutagen monitoring, and determining mutagen effects and mechanisms of mutagen action. They have played lesser roles in quantification of mutagenic activity and understanding the nature of induced mutations.Mutagen monitoring with plants, especially in situ on land or in water, will help determine potential genetic hazards of air and water pollutants and protect the genetic purity of crop plants and the purity of the food supply. The Tradescantia stamen-hair system is used in a mobile laboratory for determining the genetic effects of industrial and automobile pollution in a number of sites in the U.S.A. The fern is employed for monitoring genetic effects of water pollution in the Eastern states. The maize pollen system and certain weeds have monitored genetic effects of pesticides. Several other systems that have considerable value and should be developed and more widely used in mutagen monitoring and screening, especially for in situ monitoring, are discussed. Emphasis is placed on pollen systems in which changes in pollen structure, chemistry, and chromosomes can be scored for monitoring; and screening systems which can record low levels of genetic effects as well as provide information on the nature of induced mutations. THE VALUE OF PLANT SYSTEMS FOR MONITORING AND SCREENING MUTAGENS CAN BE IMPROVED BY: greater knowledge of plant cell processes at the molecular and ultrastructural levels; relating these processes to mutagen effects and plant cell responses; improving current systems for increased sensitivity, ease of detecting genetic and chromosome changes, recording of data (including automation), and for extending the range of genetic and chromosome end points; and designing and developing new systems with the aid of previous and current botanical and genetic knowledge.

Biological Assay↗

[Employment of continuous biotest systems for monitoring the Rhine river].

As a part of the work of the German Commission for the Prevention of Pollution of the River Rhine biological test automats are developed and proved in a research project. The joint project "Development, Testing and Implementation of Biotests for the Monitoring of the River Rhine" sponsored by the Federal Ministry for Research and Technology (BMFT) and the Federal Environmental Agency (UBA), aims to provide a scientific and technical basis for an improved Rhine monitoring system. To realize a biological effect monitoring with functional subjects at the trophic levels of producers, primary and secondary consumers and destruents, the test spectrum includes algae, mussels, daphnia, fishes, and bacteria. Moreover, at the suborganismic level a test system with plant protoplasts is tested. Assessment schemes for the evaluation of measuring data and alarm situations, and limit values for releasing alarms are defined by the Working Group "Biotests for the Monitoring of the River Rhine" (WIR). By means of applicability criteria the most suitable biotests are chosen and recommended for the use on the River Rhine. The first results are presented in this paper.

Animals↗

A portable bio-impedance system for monitoring lung resistivity.

The principles of a hybrid bio-impedance technique are implemented in a novel, lung resistivity monitoring system ("CardioInspect" Tel-Aviv University, Israel). The system is to be utilized in the clinic or at home, for daily monitoring of patients suffering from pulmonary edema. The developed system consists of an eight-electrode belt worn around the thorax, an electronic unit containing analog and digital boards, and a stand-alone DSP based system with a designated software to analyze the data. A Newton-Raphson algorithm based on the finite-volume method is employed for the optimization of the left and right lung resistivity values, making use of the voltage measurements retrieved from opposite current injections. In this preliminary study, 33 healthy volunteers were measured with the system during tidal respiration, yielding symmetric mean left and right lung resistivity values of (1205+/-163, 1200+/-165) (Omega cm). The system reproducibility was better than 2% for both within and between tests measurements, and no dependency between the reconstructed values and various anthropometric parameters was found.

Diagnosis, Computer-Assisted↗

An in line non-invasive optical system to monitor pH in cell and tissue culture.

pH is an important control parameter for maintenance of cell viability and for improving tissue functions during cell and tissue culture. pH monitoring during cell/tissue culture also provides valuable information on cell metabolic processes and living environment. In this study, an on-line, non-invasive pH monitoring system was developed for use during tissue/cell culture in a perfusion system, using an optical method. This device included light sources, light detectors, light guides and a flow cell. Phenol red was used as a pH indicator dye, and the ratio of light intensities at two wavelengths was measured at the same pH value. Low solution volume as low as around 10 microl could be used to detect pH. Compared to the conventional optical methods, this non-contact optical measurement can avoid the contamination of the tip of optical fibre during the long-term monitoring. It provides a possibility to do on-line monitoring and apply feed back control to maintain the culture environment at the desired conditions required for long-term cell/tissue culture.

Cell Culture Techniques↗

An infrared system for monitoring Drosophila motility during microgravity.

Presently, the precise mechanisms of the aging process are unknown. Examination and comprehension of the aging process in other species could lead to significant advances in the understanding of human aging. Drosophila melanogaster (fruit fly), commonly used for aging studies, is a widely studied organism in terms of behavior, development, and genetics. Previous microgravity experiments have shown a significant decrease in the life span of young male Drosophila after microgravity exposure. This decrease in lifespan may be related to locomotor activity, a convenient measure of overall physiological performance. This study describes the design and performance of a Drosophila Infrared Motility Monitoring System (DIMMS). The DIMMS uses a unique design of two infrared (IR) beams per fly to measure the locomotor activity of 240 flies. Locomotor activity is measured in terms of number of IR crossings per unit time, instantaneous velocity, and continuous velocity. Ground-based results using the DIMMS equipment agree well with previous values for Drosophila locomotor velocity. DIMMS is an improvement over equipment previously used due to its ability to continuously monitor locomotor activity throughout short-duration microgravity exposure. DIMMS is also lightweight, compact, and power efficient. DIMMS has been flight tested onboard NASA's KC-135 reduced gravity research aircraft and a Nike-Orion sounding rocket.

Aging↗

Following Shipman: a pilot system for monitoring mortality rates in primary care.

As part of the investigations into the crimes of Harold Shipman, it has become clear that there is little monitoring of deaths in general practice. By use of data on annual deaths at family physician and practice level for five English health authorities for 1993-99, we investigate whether cumulative sum charts (a type of statistical process control chart) could be used to create a workable monitoring system. On such charts, thresholds for deaths can be set, which, if crossed, may indicate a potential problem. We chose thresholds based on empirical calculations of the probabilities of false and successful detection after allowing for multiple testing over physicians or practices. We also statistically adjusted the charts for extra-Poisson variation due to unmeasured case mix. Of 1009 family physicians, 33 (including Shipman) crossed the alarm threshold designed to detect a 2 SD increase in standardised mortality, with 97% successful detection and a 5% false-alarm rate. Poor data quality, plus factors such as the proportion of patients treated by these physicians in nursing homes or hospices are likely explanations for most of these additional alarms. If used appropriately, such charts represent a useful tool for monitoring deaths in primary care. However, improvement in data quality is essential.

Data Collection↗

An on-line computer system for monitoring respiratory and cardiac functions of patients.

A computer-based noninvasive and continuous patient monitoring system for breath-by-breath assessment of cardiorespiratory functions was developed. Transthoracic impedance changes caused by respiratory and cardiac activities were measured with separate impedance plethysmographs of different frequencies. A mini-computer system calculated on-line eight respiratory parameters (VT, f, VE, PETO2, PETCO2, VO2, VCO2, and R) in cooperation with expired gas analysis data from a mass-spectrometer, and three cardiac parameters (SV, HR and Q). These parameters were displayed simultaneously at the end of each breath. In order to improve the signal-to-noise ratio of the impedance cardiogram to a level allowing computer determination, an ensemble averaging technique was utilized. The computer-derived cardiorespiratory parameters obtained during voluntary hyperventilation and a passive tilt demonstrated reasonable changes.

Carbon Dioxide↗

An automated telephone system for monitoring the functional status of community-residing elders.

We tested the reliability and validity of an automated telephone monitoring system for assessing changes in the functional status of disabled elders living in the community. The sample consisted of 20 adults older than 60 years of age enrolled in a home care program due to functional disabilities. Within a 72-hour period, each participant received, in random order, two automated and one personal telephone functional assessment as well as a home visit assessment by a case manager. The results indicated similarities between the personal and automated telephone assessments, but neither telephone method captured as many impairments as the case manager's home assessment. These findings suggest that the automated system cannot substitute for a case manager's in-home assessment, but it does offer a means to target individuals for additional professional assessment.

Activities of Daily Living↗

System to monitor a portion of the total testing process in medical clinics and laboratories: evaluation of a split-specimen design.

To evaluate a split-specimen design to identify problems in the testing process in hospital and physician office laboratories, we examined the testing for serum total cholesterol (n = 646) and potassium (n = 732) at 11 medical clinics evaluating 30-199 patients (mean, 125). Clinic personnel collected three tubes of blood from each patient. One specimen was processed routinely, the second was sent to a referral laboratory (RL), and the third specimen was sent to a holding facility for storage. The corresponding stored sample was retrieved and divided into three audit samples randomly and when result difference for the first two specimens exceeded critical values; one audit sample was sent to the original participant, the second to the RL, and the third to a referee laboratory. When three criteria were used, the result discrepancy rates were 2.5-8.7% for potassium and 1.5-4.6% for cholesterol. The split-specimen design could be implemented and evaluated as a monitoring system for a portion of the testing process.

Adolescent↗

Cortical evoked potential monitoring. A system for intraoperative monitoring of spinal cord function.

This report describes the intraoperative use of a somatosensory cortical evoked potential system to monitor spinal cord function during 300 orthopedic surgical procedures. This system requires sophisticated equipment and the establishment of normative data but has performed well with no false negatives noted. The most frequent technical problem encountered was the effect of medications and anesthetic agents, some of which impair the evoked response significantly. In this series of 300 cases, three neurologic deficits were documented intraoperatively and confirmed postoperatively. There were four cases in which changes in evoked potentials led to change in operative procedure, with no subsequent neurologic deficit. In the remaining cases, the monitoring indicated no neurologic problems during surgery, and none were noted postoperatively.

Adolescent↗

Multimicroprocessor system for online monitoring in a CCU.

A real-time monitoring system for physiological signals, developed for patients in coronary care units (CCUs), is described. This system monitors the signals that have the greatest clinical value in a CCU environment (ECG and cardiovascular pressures), taking charge of detecting dangerous situations and of extracting information significant to the correct monitoring of the patient. The information it extracts, mainly from the ECG, is presented to the user in an ergonomic way using written reports and graphs which collect and compile the information, facilitating its interpretation. Some utilities have been developed to allow the user to modify certain monitoring conditions as well as to correct results derived from them, thereby improving the reliability of the monitoring process. The system uses a multimicroprocessor architecture (imposed by the need to perform a large number of tasks in real time) with a block based on the VME bus, charged with acquiring and processing the monitored signals, and an IBM-compatible PC/XT which is used as a system user interface and a massive storage device in which the information resulting from the monitoring of signals is stored.

Coronary Care Units↗

Monitoring change in hydrological systems.

Monitoring is the process by which we keep the behaviour of the environment in view, providing essential information on how systems are changing and how fast, and allows us to learn to adjust what we are doing to get the best out of the system. This paper reviews the ways in which long-term study of the natural environment can be achieved. Three hydrological examples are then presented: nitrate leaching in a small agricultural catchment in south west England; the impact of drought on the peat-covered headwaters of the River Tees in northern England; and the impact of clear-felling on forest hydrology and nutrient export in the southern Appalachians. Monitoring programmes, if well designed and properly maintained, can provide important evidence of environmental change, revealing unexpected patterns and stimulating experimental research. The existence of long, reliable data sets considerably increases our ability to make informed decisions about the way in which we manage our river catchments.

Agriculture↗