Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Acetabulum”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67Linked to original sources

Total hip arthroplasty with a sliding iliac graft for acetabular dysplasia.

We describe a new technique of reconstruction of the deficient acetabulum in cementless total hip arthroplasty. The outer iliac table just above the deficient acetabulum is osteotomised and slid downwards. We have termed this an iliac sliding graft. Between October 1997 and November 2001, cementless total hip arthroplasty with an iliac sliding graft was performed on 19 patients (19 hips) with acetabular dysplasia. The mean follow-up was 3.4 years (2 to 6). The mean pre-operative Harris hip score was 45.1 which improved significantly to 85.3 at the time of the final follow-up. No patient had post-operative abductor dysfunction. Incorporation of the graft was seen after two to three months in all patients. Resorption of the graft and radiolucencies were infrequent. This technique is a useful alternative to femoral head autografting when the patient's own femoral head cannot be used.

Acetabulum↗

Bone remodelling around a cemented polyethylene cup. A longitudinal densitometry study.

The aims of this study were to examine the repeatability of measurements of bone mineral density (BMD) around a cemented polyethylene Charnley acetabular component using dual-energy x-ray absorptiometry and to determine the longitudinal pattern of change in BMD during the first 24 months after surgery. The precision of measurements of BMD in 19 subjects ranged from 7.7% to 10.8% between regions, using a four-region-of-interest model. A longitudinal study of 27 patients demonstrated a transient decrease in net pelvic BMD during the first 12 months, which recovered to baseline at 24 months. The BMD in the region medial to the dome of the component reduced by between 7% and 10% during the first three months, but recovered to approximately baseline values by two years. Changes in BMD in the pelvis around cemented acetabular components may be measured using dual-energy x-ray absorptiometry. Bone loss after insertion of a cemented Charnley acetabular component is small, transient and occurs mainly at the medial wall of the acetabulum. After two years, bone mass returns to baseline values, with a pattern suggesting a uniform transmission of load to the acetabulum.

Absorptiometry, Photon↗

Initial stability of modular acetabular components. Comparative in-vitro study with polyethylene and ceramic liners.

Modular acetabular components with alumina ceramic liners are currently used in total hip arthroplasty, but concerns have emerged regarding their high stiffness, which could cause impairment of stability, stress-shielding phenomena, and loosening. The purpose of the present biomechanical investigation was to compare the in-vitro initial stability of a modular press-fit acetabular component using a polyethylene liner and using an alumina liner. The initial stability was investigated by measuring the micromotion between the implant and the acetabulum during the application of physiological load (2.39 kN). The micromotion of the acetabular component was investigated in 10 acetabuli using a polyethylene liner and in 10 acetabuli using an alumina liner. Micromotion was assessed at the level of the Os ilium, Os pubis, and Os ischium using 3 electromagnetic transducers. The transducers have a sensitivity of 1 micron and a range of measurement of 500 microns. All implants have been fixed on human pelves made of polyurethane. Measurement of implant micromotion showed stable conditions at the level of the three main sectors of the acetabulum during all tests. No statistically significant differences of results were observed between the group of specimens with polyethylene liner and the group of specimens with alumina liner. The mean micromotion values of the uncemented cups were similar to the mean micromotion values of 10 cemented cups investigated to achieve comparative data of stability. In conclusion, the modular acetabular components inserted using an alumina liner showed a satisfactory initial stability in-vitro. The results do not contrast with those achieved using the same cup inserted with a polyethylene liner.

Acetabulum↗

[The HEPFIEx simulator, a device for determination of friction between femur head prosthesis and cartilage].

We describe a device designed to investigate friction between various femoral head prostheses and human acetabula. It enables not only the determination of friction and the relevance of the play between the femoral head and acetabulum, but also the evaluation of the kinematic behaviour of bipolar prostheses. In the simulator, the various femoral head prostheses are placed on a special cone and tested against a human cadaveric acetabulum. The swiveling range of the device is uniaxial, and the swiveling angle is +/- 35 degrees. The maximum force produced pneumatically is 5kN. Testing of the simulator with a TEP was successful and friction-coefficients of < 0.1 were measured, as are reported in the literature.

Acetabulum↗

Rate of degeneration of human acetabular cartilage after hemiarthroplasty.

Biopsy specimens of cartilage and subchondral bone were obtained from the weight-bearing dome of the acetabulum in twelve elderly patients who were having a revision of a hemiarthroplasty of the hip because of pain. Biopsy specimens of acetabular cartilage and subchondral bone were also obtained from eight patients of comparable age who were having a primary hemiarthroplasty for a displaced fracture of the femoral neck; these served as the control specimens. The specimens were stained with hematoxylin and eosin for the initial histological assessment of cartilage structure and cellularity as well as the integrity of the tidemark. Safranin-O and toluidine-blue stains were used to assess proteoglycan content. A histological grading scale was employed for comparative analysis of samples. The joint space of the hip was measured on the radiographs that were made before the revision and was correlated with the histological grade. Review of the histological specimens demonstrated considerable degeneration of acetabular cartilage in the patients who were having a revision of a hemiarthroplasty as compared with that in the age-matched control patients who were having a primary hemiarthroplasty. The progression in the severity of the degeneration correlated directly with the duration of articulation of the implant with the acetabulum. All six of the patients in whom the implant had been in situ for more than five years, and in whom the femoral stem was determined to be stable at the operation, had nearly complete loss of cartilage as seen on histological examination.(ABSTRACT TRUNCATED AT 250 WORDS)

Acetabulum↗

Porous-coated acetabular components with screw fixation. Five to ten-year results.

The results of 136 consecutive primary total hip arthroplasties performed by one surgeon with the Harris-Galante-I porous-coated acetabular component were reviewed at a mean of seven years (range, five to ten years). In all hips, the outer diameter of the acetabular component was the same as the diameter of the final reamer used in the preparation of the acetabulum. However, this reamer was used only briefly at the rim of the acetabulum, and therefore the components had so-called press-fit stability. A mean of four screws (range, three to six screws) were used for additional fixation of the component. The clinical evaluation was performed with use of the Harris hip score. Standardized anteroposterior radiographs of the pelvis were assessed for migration of the component, radiolucent and radiodense lines, linear wear of the polyethylene, and osteolysis. No acetabular component had been revised for loosening and none were radiographically loose at the time of the most recent follow-up evaluation. There were no complications related to the use of the screws, and no screw had bent or broken. A non-progressive radiolucent line was seen in one acetabular zone in thirty-four hips (25 per cent) and in two acetabular zones in six hips (4 per cent). No hip had a radiolucent line in all three acetabular zones. The mean rate of linear wear of the polyethylene was 0.1 millimeter per year. There was no dissociation of the acetabular liner from the metal shell. Two hips (1 per cent) had asymptomatic osteolysis in the ischium and adjacent to the rim of the acetabular component; this was treated with grafting at the site of the lesion and exchange of the femoral head and the worn polyethylene liner. Five femoral components inserted without cement and one inserted with cement were revised because of loosening. The data suggest that, at a mean of seven years, fixation of this porous-coated component was uniformly excellent. The low prevalence of radiolucent lines and the absence of loosening are probably related, in part, to the technique of implantation. The low prevalence of polyethylene wear and pelvic osteolysis is a notable improvement compared with the results of arthroplasty with other porous-coated acetabular components. Although the results of the present study are encouraging, longer follow-up is necessary to determine the prevalence of late loosening and osteolysis.

Acetabulum↗

Revision of the acetabular component of a total hip arthroplasty with cement in young patients without rheumatoid arthritis.

The results for eighty-two young patients without rheumatoid arthritis who had had eighty-seven revisions of the acetabular component because of aseptic loosening were studied. The mean duration of follow-up was approximately six years (range, 1.9 to 18.1 years). The clinical result was excellent or satisfactory for seventy-nine hips (91 per cent). However, at the latest radiographic assessment, twenty-six sockets were loose. Of the fifty hips that had had good bone stock (only slight enlargement of the acetabulum or local defects involving only one wall) before the revision, seven (14 per cent) had loosening of the socket, compared with nineteen (51 per cent) of the thirty-seven that had had poor bone stock (massive or global collapse of the acetabulum and defects involving at least two walls). The relationship between loosening and the quality of the bone stock before the revision was highly significant (p = 0.0002, chi-square test). The results of revision of the socket with use of cement and without use of any bone grafts in young patients who have poor acetabular bone stock are not very encouraging. The need for regular follow-up of all patients who have had an arthroplasty cannot be overemphasized.

Acetabulum↗

Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years.

We evaluated 377 patients (428 hips) who had been managed, by a total of fourteen surgeons at twelve clinical sites in the United States and Europe, with a porous-coated press-fit acetabular cup, a hydroxyapatite-coated threaded screw-in cup, or one of two similar designs of hydroxyapatite-coated press-fit cups between April 1987 and November 1992. The same type of hydroxyapatite-coated femoral stem was inserted without cement in all patients. After a minimum duration of follow-up of five years (mean, 7.9 years; range, 5.3 to 9.1 years), one (1 per cent) of the 131 hydroxyapatite-coated threaded cups, two (2 per cent) of the 109 porous-coated press-fit cups, and twenty-one (11 per cent) of the 188 hydroxyapatite-coated press-fit cups had been revised because of aseptic loosening. A common radiographic sign of impending failure of the hydroxyapatite-coated press-fit cups was radiolucency at the interface between the implant and the subchondral bone beneath it. This radiolucency usually was seen initially more than two years after implantation. Radiographic evaluation of the 383 acetabular implants that were in situ at the time of the most recent follow-up showed that 123 (99 per cent) of the 124 hydroxyapatite-coated threaded cups, 101 (98 per cent) of the 103 porous-coated cups, and 139 (89 per cent) of the 156 hydroxyapatite-coated press-fit cups were stable with osseous ingrowth (as indicated by the absence of radiolucency at the interface and the absence of migration within the acetabulum). The probability of revision due to aseptic loosening was significantly greater for the hydroxyapatite-coated press-fit cups than it was for the hydroxyapatite-coated threaded cups or the porous-coated press-fit cups (p < 0.001 for both comparisons). Within the group of patients who had a hydroxyapatite-coated press-fit cup, the probability of revision due to aseptic loosening was significantly greater in association with a young age (p = 0.003), female gender (p = 0.02), the use of a femoral head with a diameter of thirty-two millimeters (p = 0.018), and the use of a thin polyethylene liner (p < 0.001). We found that the hydroxyapatite-coated threaded cups and the porous-coated press-fit cups continued to perform well more than five years after the operation. The hydroxyapatite-coated press-fit cups that were revised probably failed because the fixation interface beneath the cup could not sustain the tensile stresses that were imposed between the cup and the bone by the activity of the patient. Our data suggest that, in the specific biomechanical environment of the acetabulum, physical interlocking between the cup and the supporting bone beneath it may be a prerequisite for long-term stability.

Acetabulum↗

Medial protrusio technique for placement of a porous-coated, hemispherical acetabular component without cement in a total hip arthroplasty in patients who have acetabular dysplasia.

Twenty-four hip replacements were performed with use of a medial protrusio technique to stabilize the fit of a hemispherical metal shell in the acetabulum in nineteen patients who had dysplasia of the hip. All of the hips were followed for a minimum of five years (average, seven years; range, five to thirteen years). Six of the hips were type I, seven were type II, eight were type III, and three were type IV according to the criteria of Crowe et al. The acetabular cup was implanted with the medial aspect of its dome beyond the Kohler line (drawn from the ischium along the ilioischial line) in all hips. An autogenous graft sculpted from the femoral head was used to cover 15 to 30 percent of the superolateral portion of the cup in one type-I hip, four type-III hips, and one type-IV hip. The need for these six bone grafts could have been avoided by reaming two to three millimeters more medially or by allowing 20 percent of the superolateral portion of the cup to be uncovered. Sixty to 84 percent of each bone graft was resorbed, effectively leaving the superolateral portion of the cup uncovered. The amount of the surface of the cup that was beyond the Kohler line averaged 41 percent for the six type-I hips, 43 percent for the seven type-II hips, 41 percent for six of the type-III hips, and 44 percent for one of the type-IV hips. Crossing of the ilioischial and iliopubic lines was noted on the radiographs of two type-III and two type-IV hips. Radiographs of two type-I hips and one type-II hip showed 7 to 17 percent of the surface of the dome of the cup through the internal pelvic wall (beyond the iliopubic line). None of the twenty-four metal shells were revised. A reoperation was performed on two hips to exchange a worn polyethylene insert, and three femoral components that had been fixed without cement were revised because of mechanical loosening. Wear averaged 0.26 millimeter per year in the fourteen hips that had a titanium femoral head and 0.09 millimeter per year in the nine hips that had a cobalt-chromium femoral head. The remaining hip had a ceramic femoral head, and the wear rate was 0.09 millimeter per year. The medial protrusio technique is a predictable, reproducible method for obtaining fixation of a porous-coated, hemispherical acetabular component in a dysplastic acetabulum. The technique permits the use of a porous-coated (bone-ingrowth) component; avoids the use of support bone graft and thereby reduces the operative time; facilitates rehabilitation by permitting earlier weight-bearing of the hip; and permits the use of a modular bearing surface, which may allow future exchange of only this surface rather than revision of the entire acetabular component because of excessive wear.

Acetabulum↗

Functional and oncological outcome of acetabular reconstruction for the treatment of metastatic disease.

BACKGROUND: Metastatic disease of the acetabulum can be painful and disabling. Operative intervention is indicated for patients who fail to respond adequately to nonoperative treatment. We evaluated the functional and oncological outcome of acetabular reconstruction after curettage for the treatment of refractory symptomatic acetabular metastases. METHODS: Fifty-five patients with metastatic disease of the acetabulum were treated with operative acetabular reconstruction combined with a total hip replacement. The most common primary tumor was carcinoma of the breast (eighteen patients), followed by carcinoma of the kidney (seven patients) and carcinoma of the prostate (seven patients). Forty (73 percent) of the patients presented with multiple skeletal metastases, and eighteen (33 percent) had associated visceral metastases. Twenty-eight (51 percent) had severe pain requiring continuous use of narcotics, twenty-four (44 percent) had moderate pain requiring periodic use of narcotics, and the remaining three (5 percent) had mild pain requiring use of non-narcotic analgesics. Eighteen (33 percent) of the patients could not walk, twenty-three (42 percent) needed a walker or crutches, twelve (22 percent) used a single cane, and two (4 percent) walked without assistive devices. Intralesional curettage of the tumor was performed in all of the patients. Fifty-four of the hips were reconstructed with a protrusio cup and one, with a hemipelvis endoprosthesis. Large defects were reinforced with cement and pin or screw fixation (the modified Harrington technique), which allowed transmission of weight-bearing forces to the remaining intact pelvis. Thirty-six acetabular reconstructions were performed with antegrade pins or cannulated screws; fifteen, with long retrograde screws; and four, with cement. RESULTS: The median period of survival was nine months. Patients with visceral metastases had a median period of survival of three months compared with twelve months for patients without visceral metastases (p < 0.001). Patients with breast cancer presented later in the disease process (p < 0.004) and lived longer than did those with other carcinomas (p < 0.004). Forty-five patients were evaluated three months after reconstruction. Thirty-four (76 percent) of them had relief of pain as determined by decreased use of narcotics. Nine of the eighteen patients who could not walk preoperatively regained the ability to walk. Fourteen of the seventeen patients who originally were able to walk in the community retained that ability. Thirty-three patients were available for evaluation at six months. Twenty-five (76 percent) still had relief of pain, and nineteen (58 percent) were able to walk and function in the community. Overall, fourteen (25 percent) of the fifty-five patients had moderate local progression of the disease, and five of these patients had failure of the fixation. Fourteen early complications developed in twelve (22 percent) of the patients. One patient (2 percent) died perioperatively. CONCLUSIONS: Patients who have acetabular metastases that are refractory to radiation and chemotherapy have a short life expectancy. The early, gratifying results of reconstruction validate the role of operative treatment as a short-term palliative procedure. Protrusio acetabular cups presumably compensate for deficiencies of the medial wall, while cement and pin fixation can be used effectively to reconstruct large defects in the acetabular column and dome. The low rate of fixation failure supports the biomechanical principles of the reconstruction. Generally, the reconstructions are sufficiently durable to exceed the life expectancy of the patients.

Acetabulum↗

Reliability and intraoperative validity of preoperative assessment of standardized plain radiographs in predicting bone loss at revision hip surgery.

BACKGROUND: The most challenging aspect of revision hip surgery is the management of bone loss. A reliable and valid measure of bone loss is important since it will aid in future studies of hip revisions and in preoperative planning. We developed a measure of femoral and acetabular bone loss associated with failed total hip arthroplasty. The purpose of the present study was to measure the reliability and the intraoperative validity of this measure and to determine how it may be useful in preoperative planning. METHODS: From July 1997 to December 1998, forty-five consecutive patients with a failed hip prosthesis in need of revision surgery were prospectively followed. Three general orthopaedic surgeons were taught the radiographic classification system, and two of them classified standardized preoperative anteroposterior and lateral hip radiographs with use of the system. Interobserver testing was carried out in a blinded fashion. These results were then compared with the intraoperative findings of the third surgeon, who was blinded to the preoperative ratings. Kappa statistics (unweighted and weighted) were used to assess correlation. Interobserver reliability was assessed by examining the agreement between the two preoperative raters. Prognostic validity was assessed by examining the agreement between the assessment by either Rater 1 or Rater 2 and the intraoperative assessment (reference standard). RESULTS: With regard to the assessments of both the femur and the acetabulum, there was significant agreement (p < 0.0001) between the preoperative raters (reliability), with weighted kappa values of >0.75. There was also significant agreement (p < 0.0001) between each rater's assessment and the intraoperative assessment (validity) of both the femur and the acetabulum, with weighted kappa values of >0.75. CONCLUSIONS: With use of the newly developed classification system, preoperative radiographs are reliable and valid for assessment of the severity of bone loss that will be found intraoperatively.

Acetabulum↗

Total hip replacement with the CLS expansion shell and a structural femoral head autograft for patients with congenital hip disease.

BACKGROUND: Reconstruction of a dysplastic acetabulum in a patient with osteoarthritis of the hip may be accomplished with a variety of surgical techniques. The aim of our study was to assess the outcomes of total hip replacement with the uncemented CLS expansion shell and a structural femoral head autograft to augment the deficient acetabulum in patients with osteoarthritis secondary to congenital hip disease. METHODS: Between 1990 and 1994, we used a CLS expansion shell with a structural femoral head autograft in forty-three consecutive patients (forty-three hips) with osteoarthritis secondary to congenital hip disease. The ratio of male to female patients was 5:38, and the mean age of the patients was forty-eight years. According to the preoperative radiographic assessment, the dysplasia was categorized as Crowe type I in six patients, Crowe type II in thirty-one patients, and Crowe type III and type IV in three patients each. No patient was lost to follow-up. The mean duration of follow-up was 120 months. Plain radiographs were made immediately after surgery and at the latest follow-up evaluation. Clinical outcomes were determined with use of the Harris hip score and the Merle d'Aubigné and Postel score, and a radiographic analysis was performed. RESULTS: Postoperatively, the mean Harris hip score had improved 58 points for patients with Crowe type-I and II dysplasia, 47 points for patients with Crowe type-III dysplasia, and 46 points for patients with Crowe type-IV dysplasia (p < 0.05 for all). At the latest follow-up examination, the mean Harris hip score for all patients was 92.6 points. The mean Merle d'Aubigne and Postel score was 8.3 points preoperatively and 15.8 points at the time of the latest follow-up. The mean coverage of the shell by the graft immediately after surgery was 32.2%. Osteointegration of the CLS expansion shell was evident radiographically in all forty-three hips at the latest follow-up evaluation. There were no failures of the bone grafts. Clinical survival of the CLS expansion shell with a structural femoral head autograft was 100% at a mean of ten years after surgery. The rate of survival of the shell, with radiographic signs of loosening as the end point, was 88.2% at ten years. CONCLUSIONS: The CLS uncemented expansion shell, when used with a structural femoral head autograft, provides a reliable reconstruction, augments deficient acetabular bone stock, and allows placement of the socket at or close to the anatomic center of hip rotation in patients undergoing total hip arthroplasty to treat the sequelae of congenital hip disease.

Acetabulum↗

Cementless total hip arthroplasty in patients with high congenital hip dislocation.

BACKGROUND: The optimal surgical treatment for patients with high congenital dislocation of the hip remains controversial. The purpose of our study was to evaluate the mid-term to long-term results of cementless total hip arthroplasty in such patients. METHODS: The study included sixty-eight total hip replacements performed between 1989 and 1994 in fifty-six consecutive patients with high congenital hip dislocation at our hospital. The cup was placed at the level of the true acetabulum, and a shortening osteotomy of the proximal part of the femur and distal advancement of the greater trochanter were performed in 90% of the hips. At the time of final follow-up, at a mean of 12.3 years postoperatively, fifty-two patients (sixty-four hips) were evaluated by us with a physical examination, determination of Harris hip scores, and radiographs. RESULTS: The mean Harris hip score increased from 54 points preoperatively to 84 points at the time of final follow-up (p < 0.001). There was a negative Trendelenburg sign in fifty-nine (92%) of the sixty-four hips. There were thirteen perioperative complications (19%): three peroneal nerve palsies, one femoral nerve palsy, one superior gluteal nerve palsy, four nondisplaced fractures of the proximal part of the femur, one malpositioned stem perforating the posteromedial cortex of the femur, one superficial wound infection, and two early dislocations. With revision because of aseptic loosening as the end point, the ten-year survival rate for press-fit, porous-coated acetabular components was 94.9% (95% confidence interval, 89.3% to 100%). Eight of nine threaded acetabular components were revised, and the ninth was radiographically loose at the time of the last follow-up examination. The rate of survival for the CDH femoral components, with revision because of aseptic loosening as the end point, was 98.4% (95% confidence interval, 96.8% to 100%) at ten years. CONCLUSIONS: Total hip arthroplasty, with placement of the cup at the level of the true acetabulum, distal advancement of the greater trochanter, and femoral shortening osteotomy, can be recommended for patients with high congenital hip dislocation. Complications such as wear, osteolysis, and cup revision were secondary to the suboptimal design of the acetabular components used in this series.

Acetabulum↗

Early results of the Bernese periacetabular osteotomy: the learning curve at an academic medical center.

BACKGROUND: Most reports on the results of the Bernese periacetabular osteotomy for the treatment of developmental dysplasia of the hip have been by the originators of the procedure. In 1997, we began to use this osteotomy without direct training from the originators of the procedure. METHODS: Seventy-three patients (eighty-three hips) underwent a Bernese periacetabular osteotomy between 1997 and 2003 and were followed prospectively with use of the Harris hip score to assess clinical results and with use of anteroposterior pelvic and false-profile lateral plain radiographs to assess radiographic results. The three-dimensional position of the acetabulum was recorded preoperatively and postoperatively. The mean duration of follow-up was forty-six months. RESULTS: The average Harris hip score improved from 54 to 87 points (p < 0.001). Three hips (three patients) had a conversion to total hip arthroplasty at two, three, and four years after the periacetabular osteotomy. Preoperatively, fifty-four of the eighty-three acetabula were anteverted, and twenty-nine were either retroverted or had neutral wall relationships. Postoperatively, sixty-five hips (78%) were anteverted. Radiographically, in preoperatively anteverted hips, the average center-edge angle improved from 3 degrees to 29 degrees (p < 0.0001), the average anterior center-edge angle improved from 5 degrees to 31 degrees (p < 0.0001), and the acetabular index improved from 25 degrees to 5 degrees (p < 0.0001). In preoperatively retroverted or neutral hips, the average center-edge angle improved from 13 degrees to 33 degrees (p < 0.0001), the average anterior center-edge angle improved from 15 degrees to 36 degrees (p < 0.0001), and the acetabular index improved from 19 degrees to 2 degrees (p < 0.0001). Complications included four hematomas, three transient femoral nerve palsies, two deep wound infections, and one transient sciatic nerve palsy. Nine of the ten major complications and all four of the failed osteotomies occurred in the first thirty hips in which the index procedure was performed. CONCLUSIONS: In our experience, the early results of the Bernese periacetabular osteotomy have been encouraging, with a 92% survival rate at thirty-six months. The occurrence of complications demonstrates a substantial learning curve. Recognition of the true preoperative acetabular version and reorientation of the acetabulum into an appropriately anteverted position have become important factors in surgical decision-making. LEVEL OF EVIDENCE: Therapeutic Level IV.

Acetabulum↗

CT evaluation of hip trauma.

Selection of treatment for fracture dislocations about the hip is based on the stability of the joint space, congruity of fracture fragments, the presence or absence of intraarticular fragments, and the overall condition of the patient. However, the condition of the acetabulum, femoral head, and joint space is frequently difficult to evaluate on conventional radiographs of the pelvis. To provide the orthopedist with more information on which to base treatment, 13 patients had computed tomography (CT) after accidents resulting in trauma to the hip and pelvis. The CT scan was believed to have significantly influenced the treatment in four of the patients and provided useful information in several others. CT was found to be helpful especially for evaluating presence or absence of intraarticular osseous loose fragments after reduction of the dislocated hip for evaluating congruity of the joint space after fractures of the femoral head and acetabulum. CT also provided useful information concerning the adjacent soft tissues and associated pelvic fractures.

Acetabulum↗

Arthrography as an aid to diagnosis, prognosis and therapy in Legg-Calvé-Perthes' disease.

Measurements of head diameter and acetabulum-head quotient (AHQ) were made on the plain radiographs and corresponding arthrograms of 37 consecutive patients with unilateral Legg-Calvé-Perthes' Disease (L.C.P.D.). Although on plain radiographs the affected osseous femoral capital epiphysis was slightly larger (22) the same size (9) or smaller (6) than that on the normal side, on arthrography the osteochondral head was much larger in 34 and the same size in 3 instances. In 35 cases the arthrograms revealed flattening of the osteochondral head. The AHQ computed from the arthrograms was almost invariably less than that computed from the plain radiographs. Thus the AHQ computed on arthrograms more realistically assessed the almost invariably poor head coverage in L.C.P.D. This, together with signs of flattening, diagnoses the severity of the disease process and helps to differentiate the "head at risk" which requires treatment. During arthrography the degree of abduction-medial rotation of the leg necessary for containment of the flattened protruding head within the acetabulum can be determined, allowing accurate therapy to be planned, be it operative or orthotic.

Acetabulum↗

Relation of coxarthrosis to stresses and morphogenesis. A finite element analysis.

We calculated subchondral deformations and stresses in the femoral head and acetabulum during weight bearing using finite element models. Areas of high joint contact pressures on the femoral head were shown to correspond to high hydrostatic compression in subchondral bone. The magnitude of the subchondral bone compressive hydrostatic stress correlated with cartilage thickness and was highest in the superior femoral head and moderate at the acetabular roof. The seldom contacting surfaces of the medial-inferior and peripheral areas of the femoral head and the roof of the acetabulum had lower hydrostatic compression and significant subchondral bone tensile strains tangential to the joint surface. Initial cartilage fibrillation and osteophyte formation are often found in these areas. These findings suggest that fluctuating hydrostatic pressure inhibits vascular invasion and the degeneration and ossification of articular cartilage. The generation of tensile strain may promote the degenerative process by direct mechanical mechanisms. Additionally, since tensile strains are associated with a reduction in the compressive hydrostatic stresses in the cartilage and an increase in shear stresses, their presence may permit or promote vascular invasion, cartilage degeneration, and osteophyte formation. These mechanical principles in arthrosis are the same as those that have been previously demonstrated to guide the degeneration and ossification of the cartilage primordium during skeletal morphogenesis. In this sense, arthrosis may be viewed as the final stage in the degeneration and ossification of the cartilage anlage.

Acetabulum↗

Socket loosening in arthroplasty for congenital dislocation of the hip.

Mechanical risk factors in loosening of the socket were radiographically analyzed in 123 Charnley arthroplasties performed during the period 1969-1982 for coxarthrosis secondary to congenital dislocation. The socket was placed as near the true acetabulum as possible without extensive soft-tissue release and without reinforcement of the acetabular roof by bone grafting. The rate of socket loosening was 19 percent using progression of a radiolucent line at the bone-cement interface to a width of greater than 1 mm as the criterion for loosening. Different predictors of loosening were analyzed by stepwise logistic regression analysis. Lack of lateral bony support for the socket was the prime predictor. The next most important predictors were the preoperative degree of hip dislocation and the position of the socket in relation to the true acetabulum.

Acetabulum↗