Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Titanium”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66Linked to original sources

Synthesis of 2-substituted benzofurans and indoles using functionalized titanium benzylidene reagents on solid phase.

Titanium(IV) benzylidenes bearing a masked oxygen or nitrogen nucleophile in the ortho position were generated from thioacetals, using low-valent titanocene complex, Cp2Ti[P(OEt)3]2. Methylene acetal, alkyl ether, silyl ether, fluoro, tertiary amino, and N-alkyl, N-benzyl, N-prenyl, and N-silyl tert-butyl carbamate groups were tolerated in the titanium alkylidene reagents (Schrock carbenes). Aryl-chlorine bonds were stable to the titanium benzylidene functionality, but there was poor chemoselectivity for the reduction of the thioacetal in the presence of an aryl chloride. The titanium benzylidenes converted Merrifield and Wang resin-bound esters into enol ethers. The oxygen nucleophile was masked as a TMS ether, and when the resin-bound enol ethers bearing this ortho substituent were treated with 1% TFA in dichloromethane, benzofurans were released from resin in high yields. The chameleon catch strategy ensured excellent purity. In a similar way, N-alkylated and N-silylated tert-butyl carbamates were used for the synthesis of N-alkyl and N-Boc indoles, respectively. These traceless solid-phase syntheses of heterocycles are believed to involve postcleavage modification rather than cyclative termination.

Journal Article↗

Stimulating effect of graphite admixture on hydrogen sorption-desorption properties of mechanically activated titanium powder.

The effect of graphite admixture on hydrogen sorption-desorption properties of mechanically activated electron microscopy, temperature-programmed reaction, and temperature-programmed desorption techniques. The major effect of graphite addition was found to be the formation of microporous carbon matrix particles containing randomly distributed titanium particles only several nanometers in diameter. This powder architecture enhances hydrogen transport to the titanium surface without hindrances and promotes titanium-hydrogen interaction by modifying the titanium surface and subsurface layers with interstitial carbon atoms.

Journal Article↗

Preparation of hydroxyapatite-granule-implanted superplastic titanium-alloy.

In order to obtain a biomaterial that has both biological affinity and high mechanical strength, hydroxyapatite (HAp) granules were implanted into the surface of superplastic titanium-alloy. HAp granules (32-38 microm diameter) were spread over a superplastic titanium-alloy substrate and pressed to implant the granules into the substrate. This was achieved at 17 MPa, 750 degrees C for 10 min. Only the tops of the granules, which were surrounded by the alloy, remained exposed and they were firmly stuck in the substrate. The granules were enclosed in titanium-alloy and a reaction layer was formed at their interface. The HAp-implanted titanium-alloy composites are expected to be useful as biomaterials, such as artificial bones and dental roots.

Journal Article↗

Galvanic corrosion behavior of titanium implants coupled to dental alloys.

The corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium implant. Various electrochemical parameters E(CORR), i(CORR) Evans diagrams, polarization resistance and Tafel slopes) were analyzed. The microstructure of the different dental materials was observed before and after corrosion processes by optical and electron microscopy. Besides, the metallic ions released in the saliva environment were quantified during the corrosion process by means of inductively coupled plasma-mass spectrometry technique (ICP-MS). The cast and machined titanium had the most passive current density at a given potential and chromium-nickel alloy had the most active critical current density values. The high gold content alloys have excellent resistance corrosion, although this decreases when the gold content is lower in the alloy. The palladium alloy had a low critical current density due to the presence of gallium in this composition but a selective dissolution of copper-rich phases was observed through energy dispersive X-ray analysis.

Journal Article↗

Bioactive glass granules and polytetrafluoroethylene membrane in the repair of bone defects adjacent to titanium and bioactive glass implants.

An experimental animal model was used to investigate the effect of bioactive glass (BG) granules and nonresorbable polytetrafluoroethylene (PTFE) membrane on the repair of cortical bone defects adjacent to titanium and BG implants. Thirty-two Astra(R) (diameter 3.5 mm) dental implants were inserted bicortically and 42 conical BG implants (diameter 2.5-3.0 mm) monocortically, into fitted holes of rabbit tibia. Before implantation, a standardized bone defect was created by drilling an extra hole (diameter 3.0 mm) adjacent to each implant site. Twenty-eight defects were filled with BG granules (diameter 630-800 microm) (BG group) and 28 defects were left empty but covered with PTFE membrane (PTFE group). No material was used in 18 control defects (control group). Morphometrical evaluation with a digital image analysis system was used to measure bone repair as percentages of the defect area on scanning electron microscopy (SEM) and light microscopy pictures. Bone-implant contact was measured as percentages of the thickness of the cortical bone. At 6 and 12 wk, bone repair in defects in connection with titanium implants was 23.2% and 36.6% in the BG group, 23.2% and 32.4% in the PTFE group, and 47.2% and 46.2% in control defects. Corresponding figures for BG implants were 33.2% and 40.1% in the BG group, 16.6% and 33.5% in the PTFE group, and 25.7% and 54.9% in control defects, BG granules and new bone together filled 82.7% and 68.5% of the defect area adjacent to titanium implants, and 75.9% and 74.4% of the defect adjacent to BG implants at 6 and 12 wk, respectively. Better bone-implant contact was achieved at the defect side with BG than titanium implants (77.0% versus 45.0% at 12 wk). The results indicate that BG granules are useful in treatment of bone defects adjacent to dental implants. BG coating of the implant seems to improve osseointegration in the defect area.

Journal Article↗

Analysis of the inflammatory response to titanium and PTFE implants in soft tissue by macrophage phenotype quantification.

Implants of commercially pure titanium and polytetrafluoroethylene (PTFE) were inserted in the rat abdominal wall for 1, 6 or 12 wk. The foreign body reaction was evaluated by immunohistochemical quantification of monocytes/macrophages and by the thickness of the foreign-body capsule. At all time intervals, the majority of interfacial cells were ED1-positive while ED2-positive cells were localized deeper in the tissue. Neither titanium nor PTFE displayed a significant change in capsule thickness over time. The total cell numbers decreased overtime for both types of material. At 12 wk the PTFE implants, compared to titanium, were surrounded by a significantly thicker reactive capsule with larger total cell numbers. No significant differences were seen in the macrophage subset response between the two types of implants. Thus, the present study showed differences between titanium and PTFE at 12 wk but not at earlier time points.

Journal Article↗

Preparation of hydroxyapatite-granule- implanted titanium alloy composites with a cylindrical shape.

For uniformly implanting hydroxyapatite (HA) granules into curved surfaces of titanium alloy implants such as dental roots, a new superplastic forming system was developed. By fixing PVA films with HA granules on a die's curved inner surface, HA granules are uniformly scattered and hold on the surface. The pressing system has a couple of wedges that enable press load to act on the both sides of a cylindrical titanium alloy sample arranged with its long axis perpendicular to the direction of the load in the die, and thereby the sample to expand in its radius direction. This technique could uniformly press HA granules into all the curved surface of titanium alloy. As a result, HA-granule-implanted titanium alloy composites with a cylindrical shape were formed under the conditions of 1023 K, 1 h, 1960 N in vacuo.

Journal Article↗

Surface topography modulates the osteogenesis in human bone marrow cell cultures grown on titanium samples prepared by a combination of mechanical and acid treatments.

Titanium samples of different roughness R(a) and morphology were prepared using a combination of mechanical (grinding with a SiC paper or blasting with aluminum oxide particles with 65 or 250 microm) and chemical (attack with a sulphuric acid based solution or a hydrofluoric acid based solution) treatments. The biological performance of the prepared surfaces was evaluated using human bone marrow osteoblastic cell cultures. Mechanically treated samples presented different R(a) values and surface morphology. The hydrofluoric acid solution was more effective than the sulphuric acid solution in smoothing titanium surface and also in eliminating aluminum contamination resulting from the blasting process. Bone marrow cells seeded on the different titanium samples showed a similar pattern of behavior during cell attachment and spreading. Cells proliferated very well on all the titanium surfaces and cell growth was observed during approximately two to three weeks. The samples treated with the hydrofluoric acid solution presented higher alkaline phosphatase activity. Only the blasted samples treated with the acid solutions allowed seeded bone marrow cells to form a mineralized extracellular matrix. The best biological performance was found in the blasted samples treated with the hydrofluoric acid solution, which could be related to the characteristic microtopography of these samples that presented a homogeneous and smooth roughness.

Journal Article↗

Study of interface phenomena between bone and titanium and alumina surfaces in the case of monolithic and composite dental implants.

The interface between mandibular bone and dental implants was examined with the in vivo dog model. Implant/bone interfaces were investigated for three types of materials: Ti-30 wt% Ta/Al2O3, titanium and Al2O3 using microscopy techniques covering a large magnification range: scanning electron microscopy, transmission electron microscopy, energy dispersive X-ray analysis and Auger spectroscopy. During the interaction of the Al2O3 ceramic with bone, an interfacial layer about 15 microm thick is formed. The same phenomenon was observed at the titanium bone interface, where the thickness of the layer was about 10 microm. In all cases, interface layers were sharp with well-defined borders between bone tissue and implant materials. No calcification took place inside the interface layer. A chemical analysis performed on this layer shows the presence of titanium, calcium and phosphorus in the case of titanium implants, and aluminium, calcium and phosphorus in the case of alumina implants. A rapid decrease in metal composition with increasing distances from the implant surface is correlated to a slow increase in calcium and phosphorus in the direction of the bone. Direct contact between implant and bone was observed. No biocorrosive effects were detected at the Ti-30 wt% Ta/Al2O3 metal-ceramic interface.

Journal Article↗

Human-osteoblast proliferation and differentiation on grit-blasted and bioactive titanium for dental applications.

Physico-chemical and topographical surface quality of commercially pure titanium (c.p. Ti) dental implants is one of the most influencing factors in the improvement of their osseointegration. In this sense, previously, a two-step method (2S) for obtaining bioactive blasted-rough titanium surfaces was developed for improving short-term (due to its bioactivity) and long-term (due to its roughness) osseointegration. This 2S-method consists of: (1) Grit blasting on titanium surface in order to roughen it, and (2) thermo-chemical (TCh) treatment in order to obtain a bioactive surface with bone-bonding ability. The aim of the present work is to evaluate the in vitro human-osteoblast response (proliferation, differentiation - ALP activity- and cell morphology-studied by environmental scanning electron microscopy) of rough c.p. Ti (grit blasted), bioactive c.p. Ti (thermo-chemically treated) and rough-bioactive c.p. Ti (2S-treated). Different grit materials (Al(2)O(3) and SiC) have been used in order to investigate their influence. The results showed that cell adhesion was statistically higher for the rough and bioactive surfaces, whatever the grit used. Cells proliferated very well on all the c.p. Ti surfaces. If comparing groups with and without TCh (all other treatments being equal) the ALP was always higher in the groups with TCh, indicating stimulation of osteoblast differentiation because of TCh, more significantly in the groups that were first blasted. Those ALP results were accompanied by a decrease in the value of proliferation, which shows the good behavior of the cells. This results suggest that a rough and bioactive-titanium surface obtained by 2S-treatment enhances adhesion and differentiation activity of human osteoblasts cells.

Journal Article↗

Effect of annealing titanium on in vitro bioactivity.

In order to modify titanium surfaces for various biological applications, bioactive and pure titanium oxide thin films were coated on the titanium by thermal oxidation technique. The commercially pure titanium discs after polishing were heated at 500, 550, 600, 650 and 700 degrees C, respectively, for 10 min in air or in argon. To evaluate the ability of calcium phosphate formation, samples after annealing were soaked in the Eagle's minimum essential medium solution. Surface morphology and chemical composition of the samples before or after immersion were characterized by field emission - scanning electron microscopy and energy dispersive X-ray spectrometry.

Journal Article↗

Impurities block the alpha to omega martensitic transformation in titanium.

Impurities control phase stability and phase transformations in natural and man-made materials, from shape-memory alloys to steel to planetary cores. Experiments and empirical databases are still central to tuning the impurity effects. What is missing is a broad theoretical underpinning. Consider, for example, the titanium martensitic transformations: diffusionless structural transformations proceeding near the speed of sound. Pure titanium transforms from ductile alpha to brittle omega at 9 GPa, creating serious technological problems for beta-stabilized titanium alloys. Impurities in the titanium alloys A-70 and Ti-6Al-4V (wt%) suppress the transformation up to at least 35 GPa, increasing their technological utility as lightweight materials in aerospace applications. These and other empirical discoveries in technological materials call for broad theoretical understanding. Impurities pose two theoretical challenges: the effect on the relative phase stability, and the energy barrier of the transformation. Ab initio methods calculate both changes due to impurities. We show that interstitial oxygen, nitrogen and carbon retard the transformation whereas substitutional aluminium and vanadium influence the transformation by changing the d-electron concentration. The resulting microscopic picture explains the suppression of the transformation in commercial A-70 and Ti-6Al-4V alloys. In general, the effect of impurities on relative energies and energy barriers is central to understanding structural phase transformations.

Journal Article↗

Comparison of SAGB QC "classic" titanium port and Velocity port: pilot phase prospective randomized study on perioperative and short-term postoperative implantation outcomes.

BACKGROUND: Port implantation in adjustable gastric banding (AGB) is usually considered as the least compelling, however, it is one of the very important parts of the operation. Port placement can take up to 10% of the overall AGB operating time, and inadequate technique can result in complications in the short- and long-term postoperative period (port torsion, infection, protrusion, port-site persistent pain, etc). METHODS: From Dec 2005-Feb 2006, 40 consecutive patients were recruited into a Pilot phase prospective randomized study and operated in a single institution by bariatric teams with >300 SAGB experience. In 2 patient groups, intraoperative and immediate postoperative outcomes of the SAGB QuickClose (SAGB QC) "classic" titanium port and Velocity port were compared. Recorded parameters were: preoperative BMI and sex; duration of port implantation (min); length of incision (mm); complications (signs of infection/skin reaction, port-torsion, protrusion, etc); port-site pain scoring (day 1, end of week 1 and 6 postoperatively). RESULTS AND CONCLUSIONS: 1) Velocity port implantation time was significantly shorter than that in "classic" titanium port (mean 2.5 min vs 6 min, P<0.01). 2) Port-site skin incision was longer in the Velocity group (45 mm) compared to the "classic" titanium port group (35 mm). 3) Reduction in patient subjective pain complaints in favor of Velocity port recipients was noted in the immediate postoperative period but no difference at 6 weeks after the operation. 4) Port-site infection occurred in 1 patient from the "classic" titanium port group and in none in the Velocity group.

Adult↗

The use of prefabricated titanium tissue abutments for the construction of a maxillary subperiosteal implant.

This article presents a bimodal procedure for a patient with an implant-supported fixed partial denture (FP2 class of Misch) where endosteal implants (EOIs) and a subperiosteal implant (SPI) were indicated in different sections of the same arch. In edentulous patients, heterogeneous bone volume and density may be encountered in different regions of the same arch. When the available bone is favorable, the use of EOIs is simpler and less time consuming. An SPI is indicated when the available bone is severely resorbed, as in the type I division C, type II divisions C and D, and type III divisions C and D. The main advantage of the described combined technique is that it offers an alternative to invasive surgeries such as iliac crest bone grafts or various surgical augmentation procedures. The second advantage is the very brief healing period after insertion of the SPI before prosthetic loading. Planning, design, laboratory construction, surgical application, and prosthetic rehabilitation for bimodal implant treatment are described. Prefabricated titanium tissue abutments are used in the fabrication of the posts of the anterior titanium SPI. Titanium tissue abutments are placed in the waxup stage of the SPI before the casting of the titanium SPI. Posterior fixtures are EOIs. An anterior SPI with 4 posts and 4 posterior EOIs provides a combination of support for the screw-retained fixed maxillary denture of Misch's FP2.

Alveolar Bone Loss↗

The early remodeling phases around titanium implants: a histomorphometric assessment of bone quality in a 3- and 6-month study in sheep.

The purpose of this study was to evaluate the quality of the bone matrix around commercially pure titanium implants at 3 and 6 months postplacement in sheep. Implants were placed in the corticotrabecular areas of both femurs in 6 animals. Each animal received 4 Euroteknika implants in the right femur and 4 Nobel Biocare implants in the left femur. Bone blocks containing the implants were studied undecalcified after being embedded in methylmethacrylate. Sections were stained with toluidine blue and basic fuchsin. The amount of bone around the implants, the contact interface between the implant and bone, and the mineral apposition rates were measured. The fractional amount of woven bone could be quantified because of its high glycosaminoglycan content. No differences could be observed between the 2 types of implants. Total bone volume did not increase around both types of implants between 3 and 6 months, indicating that ankylosis was rapidly achieved. In contrast, in the area in contact with the implant, the bone-titanium interface drastically increased and the mineral apposition rate decreased. The fractional volume of woven bone around implants was considerably reduced after 6 months. Bone quality around implants was improved at 6 months (volume of woven bone near zero), and true osteonic structures were observed in close contact with titanium. The remodeling process appeared to improve bone quality and increase the bone-titanium interface around implants, while the net bone quantity necessary to immobilize implants was achieved rapidly and remained unchanged.

Animals↗

[Effect of graphite and phosphate investments on the biological characteristics of pure titanium castings].

OBJECTIVE: To investigate the effect of surface structural changes caused by graphite and phosphate investments on the biological characteristics of pure titanium castings. METHODS: Round casting pads of pure titanium were processed by graphite and phosphate investments respectively, then grouped into four. With the control of guta purca of the same size, Ultraviolet spectrometry was used to test the cytotoxicity of samples via the ISO, GB and Shanghai biomaterial research and testing center's standards. Mucous irritation test was performed on hamsters' pouch. RESULT: Titanium castings obtained from both investment materials have reached the national standard of cytotoxicity and mucous irritation test no matter they have been undergone surface treatment or not. CONCLUSION: Both investment materials cause no obvious changes on biological characteristics of pure titanium castings with the existing of surface structural changes.

English Abstract↗

[Experimental study on the Biomaterial/Porous Titanium composite dental implants]

This study investigated the tissue compatibility of bone morphogenetic protein (BMP) /biologic ceramic/porous titanium implant,BMP/porous titanium implant,biologic ceramic/porous titanium implant and porous titanium implant by LM,SEM,EDXA.The results showed that the new bone formation and new bone mature were earlier in the BMP composite implants treated group.BMP uncomposite implants had no evident difference in the time of new bone formation, but the interface bonding ways had significant difference.

Journal Article↗

An adjustable, butterfly-design, titanium-expanded polytetrafluoroethylene implant for nasal valve dysfunction: a pilot study.

OBJECTIVE: To investigate the design of a simple, adjustable, biocompatible nasal implant that consistently corrects nasal valvular dysfunction. METHODS: This study presents data on an adjustable titanium-expanded polytetrafluoroethylene (ePTFE) implant designed as a spanning butterfly graft. Each patient was measured for implant effectiveness subjectively by patient questionnaire and objectively with static and dynamic photographs as well as acoustic rhinomanometry data. RESULTS: Rhinomanometry studies, photographic evidence, and patient questionnaires revealed that a great improvement in the nasal airway can consistently be achieved at the level of the nasal valve using the titanium-ePTFE butterfly design implant. CONCLUSION: The titanium-ePTFE butterfly-design implant provides a consistent and adjustable correction of the dysfunctional nasal valve.

Fluorocarbon Polymers↗