Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Surgical Instruments”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66Linked to original sources

Minimally invasive approach to the cervical spine: a proposal.

BACKGROUND AND PURPOSE: During the last 3 years, a minimally invasive video-assisted approach for parathyroidectomy and thyroidectomy has been developed. Because of the good exposure of the cervical spine during these procedures, the authors decided to perform an anatomic-radiologic study in order to evaluate which cervical vertebrae could be reached by this minimally invasive approach. PATIENTS AND METHODS: Three consenting patients, two undergoing minimally invasive parathyroidectomy and one a conventional operation for C4-C5 disc herniation, were selected for this study. The procedure was carried out through a single 1.5-cm central skin incision above the sternal notch. After opening of the cervical linea alba, dissection was performed under endoscopic vision, without using any CO2 insufflation or trocar. After exposure of the prevertebral fascia, an operative tube was introduced through the cervical incision in order to maintain the operative space without using conventional retractors. RESULTS: Through this operative tube, it was possible to introduce both a 5-mm (or 3-mm) endoscope and the surgical instruments. In our patients, we inserted a 1-mm metal probe to exactly localize during fluoroscopy the vertebrae reached by the dissection (C2-C7). CONCLUSIONS: This study shows the feasibility of an anterior minimally invasive approach to the cervical spine. Although the exact indications have to be verified, a video-assisted approach could add some advantages to the well-known benefits coming from the anterior approaches to the cervical spine, especially in terms of cosmetic results and postoperative course and recovery.

Cervical Vertebrae↗

Management of benign adnexal masses by vaginal route.

Until recently, surgical treatment of a benign adnexal mass implied a laparotomy. In recent years, the development of laparoscopic surgery, as well as ultrasound-guided aspiration techniques, have significantly modified the treatment options for these patients. These procedures have shown considerable advantages. They have reduced surgical trauma and have shortened the hospital stay. We present the results of our experience on the feasibility of a trans-vaginal surgical approach for the removal of benign adnexal masses. This technique, using traditional and cheap surgical instruments, allows the surgeon to excise benign adnexal masses, by entering the peritoneum through the posterior vaginal fornix and thus avoids the trauma of laparotomy. Fifty-four patients were operated on by this technique at our Department. The mean age was 39 years (range 21-66). In all cases, the operation was completed by the trans-vaginal approach. The median operative time was 30 minutes (range 20-45), and no blood transfusion was needed. The pathological diagnoses were as follows: functional ovarian cyst; 19, endometriotic cyst; 18, dermoid cyst; 11, parovarian cyst; 4 and peduncolated fibroid of the uterine fundus; 2 cases. The diameter of the adnexal masses ranged from 3 to 10 cm (median of 6 cm). In 30 cases, a conservative surgery was done (including 2 myomectomies), whereas in 24 cases, the adnexectomy was needed. Median post-operative stay in hospital was 4 days (range 1-14). This study shows the feasibility of trans-vaginal surgical approach for benign adnexal masses. The advantages and limitations of this technique, as well as of the traditional and laparoscopic surgery are considered and discussed. We believe that the transvaginal approach could be useful and cost-effective for the treatment of selected cases of adnexal masses.

Adnexal Diseases↗

[In vitro antimicrobial activity of glutaraldehyde plus O-phenylphenol association (ratio 2:1)].

BACKGROUND: The correct use of antiseptics, disinfectants and sterilization processes to inactivate or remove micro-organisms is an essential component of an effective infection control program. To reach this result the use of phenolic detergent-disinfectants which work well as a presoak has always been suggested in lieu of sterilization involving submerging instruments in a properly prepared glutaraldehyde solution for about 6 to 10 hrs. This study investigated the in vitro effectiveness of disinfectant solution containing 2% glutaraldehyde and 1% o-phenylphenol. METHODS: The organisms used were purchased from the American Type Culture Collection (Escherichia coli ATCC 25922, Candida albicans ATCC 10231, Pseudomonas aeruginosa ATCC 27853, Staphylococcus aureus ATCC 25923, Staphylococcus epidermidis ATCC 12228), and from our clinical collection (Proteus mirabilis CH 14, Klebsiella oxytoca CH 22, Serratia liquefaciens CH 90). MIC and MBC were evaluated as testing solution for antimicrobial activity. The contact time studied between disinfectant and bacteria were 30 sec, 1, 2, 5, 10, 20 and 30 min. RESULTS: The results showed that MIC values for most bacteria were 3.75 mg/ml. The MBC values were similar or higher than the MIC. The disinfectant solution killed E. coli and C. albicans already after 10 min, but for S. aureus 30 min was necessary. CONCLUSIONS: This study proved that this solution attained the sterilization of surgical instruments in good timing and at low cost.

Anti-Bacterial Agents↗

[Neurological complications of surgery for spinal deformities].

The aim of this study was to precisely analyse the physio-pathogenic mechanisms, bring to light the risk factors, and find a more practical way of proceeding in spinal surgery. Out of 667 spinal instrumentation surgical operations carried out between 1980-1989, we found 33 (4.8 per cent) neurological complications and have divided them into 2 groups: 7 peripheral complications, 26 cord and central complications. After further analysis, especially of the cord complications (2.5 per cent), we were able to pick out the factors which influence the rate of neurological complications and their evolution: secondary aetiology and the kyphotic composition of spinal deformation, and above all the notion of cord at risk. The delay of cord complications and especially the relation between the severity of the neurological syndrome and its evolution is extremely important. Somesthesic evoked potential monitoring confirmed that per operative diagnosis of a cord injury is possible. The steps to take when confronted with neurological complications, depend on the results of many examinations: pre and post-operative neurological evaluations electrophysiological exploration of the cord and neuro radiological explorations (myelography, scanner and IRM). This helps to complete aetiology and eliminate mechanical causes, which are the only positive indications of iterative surgery. The problems of instrumentation removal in emergency and the legal-medical aspect brought on by this type of complication are discussed.

Humans↗

Keratomileusis-in-situ using manual dissection of corneal flap for high myopia.

Overcorrection, regression and haze are some side-effects found after excimer laser photorefractive keratectomy (PRK) for high myopia. A new method attempts to avoid photoablation through Bowman's layer, using the stroma to flatten the cornea without use of a microkeratome. Manual surgical instruments such as the diamond blade, spatula, Pierce forceps, and Vannas scissors are used to remove a disc of anterior cornea. Minimal topical corticosteroids are used, avoiding the complications of prolonged corticotherapy. Six eyes underwent manual excimer laser keratomileusis-in-situ. Postoperatively, the epitheliums in these eyes initially were dry and excoriated. By the twentieth day, however, the eyes had re-epithelialized and recovered. The optical effect is the same as when keratomileusis is used. No more than three-fourths of the pre-existing myopia was used in the program as some undercorrection was desired.

Adult↗

Port-access coronary artery bypass grafting: a proposed surgical method.

Minimally invasive surgical methods have been developed to provide patients the benefits of open operations with decreased pain and suffering. We have developed a system that allows the performance of cardiopulmonary bypass and myocardial protection with cardioplegic arrest without sternotomy or thoracotomy. In a canine model, we successfully used this system to anastomose the internal thoracic artery to the left anterior descending coronary artery in nine of 10 animals. The left internal thoracic artery was dissected from the chest wall, and the pericardium was opened with the use of thoracoscopic techniques and single lung ventilation. The heart was arrested with a cold blood cardioplegic solution delivered through the central lumen of a balloon occlusion catheter (Endoaortic Clamp; Heartport, Inc., Redwood City, Calif.) in the ascending aorta, and cardiopulmonary bypass was maintained with femorofemoral bypass. An operating microscope modified to allow introduction of the 3.5x magnification objective into the chest was positioned through a 10 mm port over the site of the anastomosis. The anastomosis was performed with modified surgical instruments introduced through additional 5 mm ports. In the cadaver model (n = 7) the internal thoracic artery was harvested and the pericardium opened by means of similar techniques. A precise arteriotomy was made with microvascular thoracoscopic instruments under the modified microscope on four cadavers. In three other cadavers we assessed the exposure provided by a small anterior incision (4 to 6 cm) over the fourth intercostal space. This anterior port can assist in dissection of the distal internal thoracic artery and provides direct access to the left anterior descending, circumflex, and posterior descending arteries. We have demonstrated the potential feasibility of grafting the internal thoracic artery to coronary arteries with the heart arrested and protected, without a major thoracotomy or sternotomy.

Anastomosis, Surgical↗

[Aorto-bifemoral bypass through retroperitoneal "mini"-incision (preliminary report)].

The large vertical midline or transverse transperitoneal approaches used to the conventional aortoiliac reconstruction are accompanied with a relatively high postoperative morbidity and mortality rate (2% to 5%) even in patients who are good risks undergoing aortic surgery. The purpose of this study was develop a new technique for aorto-bifemoral bypass operation to minimize the operative stress on these patients. The recommended left paramedian retroperitoneal approach using 5-6 cm skin-incision and a special retractor with three dimensional vision and using modified surgical instruments directly with eye control, offers the possibility to decrease the operative stress significantly and the sufficient control of the serious bleeding might occur. If it is necessary this exposure can be immediately converted to a conventional approach by simply enlargement of the incision. In our first case the functional results were very good and consequently hospitalization time and the convalescence period were short. This minimal access approach appears to diminish the catabolic response and is hopefully associated with accelerated recovery and virtual abolition of large wound-related complications. It could become the procedure of choice for selected patients with obstructive or aneurysmal aorto-iliac disease.

Anastomosis, Surgical↗

Experiences in intraoperative computer-aided navigation in ENT sinus surgery with the Aesculap navigation system.

Five patients with chronic sinus pathology and an indication for sinus surgery were selected. For intraoperative navigation, we used Surgical Planning and Orientation Computer Systems (SPOCS) Aesculap navigation software (ISG Technologies, Mississauga, Ontario, Canada) and surgical instruments fitted with light-emitting diodes. Navigation procedures are described in detail in the article. The system's precision was measured by pointing at anatomical landmarks. The accuracy was measured as the distance in millimeters between the bony structures of the computed tomographic (CT) scan on screen and the cross-hair of the pointer tip displayed on the screen. Another parameter of the system's accuracy was calculated by the system itself as the root mean square error in millimeters between the markers' position as registered and their position in the CT data set. Axial 3/3/1-mm spiral CT provided sufficient resolution, and data transfer via optical disk was practicable. Positioning of the navigation equipment required some experience, and the registration of the patient's head position also needed attention, as the markers have to be pointed at precisely. During the operation, the position of the head-tracking system on the patient's head must remain unchanged to ensure a correct navigation display. The main advantage of the computed navigation system was the constant orientation provided during the sinus surgical procedure. Borders and critical anatomical structures could be identified in the corresponding CT data set, thus enabling the surgeon to decide on subsequent procedures. Use of the navigation system was found to increase the operation time by about 1 h, resulting in additional time under anesthesia. We found the SPOCS Aesculap computed navigation system to be an established technical aid, ready for use in ENT sinus surgery. In the cases reported here, a precision between 1 and 3 mm was obtained.

Humans↗

Minimally invasive extraperitoneal lymphadenectomy: clinical validation of an original technique.

PURPOSE: To validate an original technique described for pelvic node dissection. PATIENTS AND METHODS: A series of 192 patients were included in this study. The surgical technique we reported in 1987 is based on the use of a special retractor called the pelvioscope. The incision is the classical MacBurney incision on the right and its equivalent on the left. After the division of the muscles, the peritoneum is mobilized medially, and the pelvioscope is introduced. The node resection is then performed with classical surgical instruments. RESULTS: In total; 151 bilateral, 20 unilateral right, and 21 unilateral left node dissections have been performed. In one case, dissection was not possible on both sides, and in two cases, the dissection was not complete on one side (patients previously operated on). The average intraoperative time was 69 minutes for a unilateral procedure and 103 minutes for a bilateral procedure. The mean number of pelvic lymph nodes removed was 5.6 on each side. The overall rate of complications was 7.3%. CONCLUSION: The effectiveness of this minimally invasive surgery is clear, and the morbidity is low.

Adult↗

Localized sinus elevation and osteocompression with single-stage tapered dental implants: technical note.

In the atrophic posterior maxilla, placement of longer (at least 10 mm) and wider diameter implants may significantly improve long-term results, but sinus grafting is often necessary to provide sufficient bone volume for implant support. The crestal approach to sinus augmentation requires penetration of the sinus floor with surgical instruments that are often difficult to control; there is a high risk of damaging the schneiderian membrane. Fabricating a round cutting rim at the apical end of a single-stage tapered implant can provide a controlled method of gently penetrating the sinus floor prior to grafting and placement of the definitive implant. In soft type 4 bone, the single-stage tapered implant design can help to enhance initial stabilization through lateral osteocondensation of the receptor site. Localized sinus elevation with osteocompression utilizing single-stage tapered implants may offer a simplified approach to the complex clinical challenge of successfully restoring the atrophic posterior maxilla.

Bone Density↗

Role of the environment of the operating suite in surgical wound infection.

Most surgical wound infections are acquired in the operating room from the patient's own microbial flora. The remainder are acquired mainly from the staff in the operating room during surgery. The inanimate environment (e.g., walls, floors, and surgical instruments) has little relevance to the spread of infection. Because the air is an important route of spread in joint prosthesis operations, the routine use of an ultraclean air system and exhaust-ventilated clothing is frequently recommended. The value of such a system in other types of clean surgery is doubtful, but other measures, such as the following, may provide similar results at less cost: reduction of the number of persons in the operating room; a policy of not opening doors during operations; the use of comfortable, washable, bacteria-impermeable clothing by the operating-room staff; and concentration of the airflow over the operation site rather than over the whole operating room.

Air Microbiology↗

L5 vertebrectomy for the surgical treatment of spondyloptosis: thirty cases in 25 years.

STUDY DESIGN: Retrospective review. OBJECTIVES: To review the long-term results, complications, and predictability of outcomes of the L5 vertebrectomy and reduction of L4 onto S1 for the surgical treatment of fixed spondyloptosis. SUMMARY OF BACKGROUND DATA: Before the development of the procedure, surgical instrumentation with Harrington rods and posterolateral fusion, or fusion in situ with cast immobilization, with or without a period of bedrest, in the cast, were the alternatives for patients who elected operative treatment. METHODS: Charts, operative notes, hospital and office records, preoperative and postoperative radiographic studies, and clinical photographs were reviewed for the 30 patients who had had the L5 vertebrectomy, over the past 25 years. The average follow-up of the patients was 15 years. The follow-up was performed by the treating physician/surgeon. RESULTS: The clinical results of the first 16 patients were independently reviewed by a surgeon who was not involved in the patients treatment, at all. His independent review indicated that the patients were functioning well. All of them would recommend the surgery to other patients who needed it. None of them was taking narcotic medication on a regular basis. The follow-up of the additional 14 patients operated since that review was performed by the author. The results of the patients operated since 1994 was the same as the group operated before 1994, except there have been 2 patients who had to have surgical revision and reinstrumentation for screw fracture, although neither lost reduction, as a consequence of their nonunion and screw fracture. Both healed their reconstruction, following removal and replacement of the fractured pedicle screws and grafting of the nonunion. None of the patients has required any treatment at all (surgical or nonsurgical) for "junctional problems" with follow-up, now, on the earliest patients, up to 25 years. Improvement in the "spinal performance" of the patients, in particular the resolution of the "crouch gait," which many of them showed before surgery, is particularly gratifying to them, since, for that group, the improvement in gait efficiency is particularly dramatic. CONCLUSIONS: Extensive review of all the complications in the series is accomplished in the manuscript. While 23 of the patients have had some temporary clinical deficit in the L5 root for from 6 weeks to 3 years following their reconstruction, all but 2 have recovered fully, and only 2 of the patients wear ankle foot orthoses (AFO) on a regular basis. No patient has had any problem with bowel or bladder or sexual neurologic deficit, but 1 patient does have retrograde ejaculation.

Adolescent↗

The pulsed holmium: yttrium-aluminum-garnet laser. Applications to ankle arthroscopy.

The holmium:YAG laser has many advantages over conventional surgical instrumentation and techniques in ankle arthroscopy. These include minimal mechanical damage to surrounding tissue structures, better access to tight recesses, and the ability to coagulate, smooth, ablate, and weld tissues. The laser also offers improved contouring of damaged articular surfaces, all with a single instrument. The holmium:YAG laser uses a wavelength of 2.1 microns, which is strongly absorbed by water, the major component of tissue. This wavelength allows the laser to deliver a consistent tissue effect to both pigmented and nonpigmented tissues. It currently may transmit up to 60 watts of power to tissue in high-energy, short-duration pulses. The holmium:YAG laser also operates in a fluid medium, which provides a near physiologic environment and maintains continual irrigation. The holmium:YAG laser beam is transmitted through a flexible fiberoptic handpiece, which greatly increases maneuverability. A variety of angled laser tips are available, depending on the pathology type and location. Different tissue effects can be created by varying the tip to target distance. All these qualities provide precise control without significant thermal damage and make the laser ideal for application to articular structures of the ankle joint. The holmium:YAG laser is a safe and effective arthroscopic instrument with a promising future. We have used it, along with traditional shavers and abraders, to effectively treat numerous pathologies of the ankle joint. The laser's versatility in cutting, ablation, and coagulation has been uniformly successful. Patients surveyed postoperatively have reported less overall symptoms and faster healing. They have reported a decrease in ecchymosis, edema, and postoperative pain. Patients' return to full activity has appeared to be quicker with the use of holmium:YAG laser therapy. Although our results have thus far been very encouraging, further research and clinical applications in the use of the holmium:YAG laser need to be continued.

Ankle Joint↗

Iatrogenic biliary tract complications: radiologic features and clinical significance.

Thirteen intrahepatic and 22 extrahepatic biliary tract complications were detected radiologically in 35 adult patients who had undergone cholecystectomy and bile duct exploration. Intraoperative usage of Fogarty balloon catheters to extract biliary calculi without fluoroscopic guidance resulted in focal ectasia or rupture of intrahepatic radicles in two and seven cases, respectively. Metallic surgical instruments such as Bakes dilators and biliary forceps or clamps accounted for most of the common duct injuries; these were manifested as submucosal dissection (two cases), transmural laceration (four cases), or localized trauma with subsequent stricture (three cases). Technical mishaps during T-tube placement led to common duct perforation (four cases) and extraluminal malposition of T tubes (three cases). The remaining complications included choledochoduodenal fistula (three cases), biliovenous fistula (two cases), biloma (three cases), and retained intraductal fragments of biliary drainage catheters (two cases). Knowledge about radiologic features and causal factors of such iatrogenic processes can play a crucial role in their prevention, correct diagnosis, and management.

Adolescent↗

Tonsillectomy using the thermal welding system.

OBJECTIVE: To evaluate and introduce a new method of tonsillectomy using the Thermal Welding System (TWS). METHOD: The TWS is a new surgical instrument which uses direct heat and pressure to seal and divide tissues. Fifty consecutive patients underwent tonsillectomy with the use of the TWS. Inclusion criteria were chronic tonsillitis, peritonsilar abscess history and obstructive sleep apnea syndrome. Patients undergoing adenoidectomy or any other procedure together with tonsillectomy and patients with bleeding disorders were excluded. Intraoperative bleeding, operative time, complication rates and return to normal diet were evaluated. RESULTS: There was no measurable bleeding during surgery in any case. No postoperative hemorrhage or other complication occurred. Mean operative time was 23 min. Mean time for return to normal diet was 8.7 days. CONCLUSIONS: The TWS was found quite effective and safe, providing sufficient hemostasis and minimal intraoperative blood loss.

Adolescent↗

Wire scalpel for surgical correction of soft tissue contour defects by subcutaneous dissection.

BACKGROUND: Increasing demand exists for cosmetic correction of soft tissue contour defects. Treatments include simple tissue augmentation techniques or more complex surgeries with consequent relevant recuperation time for the patient. The search for new simple techniques to correct scars and age-related wrinkles and folds is therefore one of the main goals of cosmetic dermatologic surgery. OBJECTIVE: To improve the cosmetic outcome of patients suffering from soft tissue contour defects by the use of a novel surgical instrument and technique, subcutaneous dissection by wire scalpel. METHODS: Fifty-four patients were treated with the wire scalpel technique with no skin incisions to correct a total of 132 depressed cosmetic defects of the face. Forehead lines, glabellar, nasolabial and oral commissure folds, upper lip wrinkles, and acne scars were treated. A 2-month to 4-year follow-up allowed subjective and photographic evaluation of results. RESULTS: Good or satisfactory results were obtained in 79.7% and 16.6% of the cases, respectively. Minor complications did not change the overall positive outcome of the surgery. CONCLUSION: Subcutaneous dissection by wire scalpel is a simple, safe, and effective method to improve the contour appearance of patients affected with scars or age-related contour defects.

Acne Vulgaris↗

[Reconstructive microsurgery].

Progress in microsurgery has been accomplished by the technical improvements of the operative microscope and other delicate surgical instruments. Therefore, even small arteries as well as female tuba and male deferens, either presenting mechanical obstruction or a section, can be reconstructed. The same procedure may be applied in case of nerve injuries. Since Microsurgery was born, it has been employed in different medical fields offering lately good chances in sterility. Furthermore, microsurgical techniques offer a great support to Plastic Surgery. In fact, it is possible to repair wide tissue damages of the skin, muscles or bones using free flaps. The percentage of success of this Surgery increased the overall percentage obtained in General Surgery. Therefore a close multidisciplinary relation between the different Medical fields is absolutely required for a correct application of microsurgical techniques.

Adolescent↗

Totally minimally invasive robot-assisted unstented pyeloplasty using the Zeus Microwrist Surgical System: an animal study.

BACKGROUND: Minimally invasive pyeloplasty is a difficult procedure even for an expert laparoscopic surgeon. The major difficulty is associated with the limitations of intracorporeal suturing and knot tying. Surgical robots, which hold minimally invasive surgical instruments, have wrists and provide tremor filtration and motion scaling that might be expected to facilitate complex procedures in newborns. METHODS: Seven survival piglets (4.0-7.5 kg) underwent a totally minimally invasive robot-assisted unstented pyeloplasty employing the Zeus Robotic Microwrist System. The ureter was transected at the level of the ureteropelvic junction and 8 mm was resected. The unstented anastomosis was fashioned with running suture and intracorporeal knot tying. The animals were recovered and intravenous urography was performed at 1 month. After sacrifice, the anastomosis and the kidney were evaluated grossly and histologically for leak, caliber, and healing. RESULTS: All animals survived the procedure without postoperative complications. The mean robotic setup time was 19 minutes (range, 10-30 min), mean anastomosis time 51 minutes (range, 39-63 min), and mean total operation time 76 minutes (range, 57-87 min). The urography showed hydronephrosis in the first animal. The other 6 animals had no abnormalities. Histopathology demonstrated severe hydronephrosis in the first pig and moderate hydronephrosis in the sixth and seventh. All other animals had no sign of hydronephrosis. All anastomoses were well healed and intact. CONCLUSIONS: Robot-assisted laparoscopic pyeloplasty is a technically feasible procedure with acceptable morbidity in an animal model. The robotic technology enhances surgical dexterity and precision. Robotic assistance can increase the applicability of minimally invasive surgery to complex procedures in children.

Anastomosis, Surgical↗