Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Monitoring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66Linked to original sources

Monitoring of ovulation induction.

The plasma hormonal patterns of the normal menstrual cycle have been reviewed. A consistent cyclic pattern of plasma hormone levels is observed in LH, FSH, estrogens, and progestins in the menstrual cycle. Other plasma hormones, such as ACTH, growth hormone, TSH, and PRL, as well as androgens and corticosteroids, fluctuate throughout the menstrual cycle without any consistent pattern during the ovulatory cycle. FSH, LH, E2, E1, P, T, and A levels during the induced ovulatory cycle are presneted for comparison. In the gonadotropin-induced ovulatory cycle most hormones behave in a manner similar to that in the normal ovulatory cycle, except for FSH levels, which rise continuously throughout the follicular phase of the cycle. Following ovulation in the gonadotropin-induced cycle, T rises above normal levels. Early in the clomiphene-induced ovulatory cycle, unlike the normal cycle, LH is distinctly elevated. Levels of both LH and FSH in the rest of the cycle simulate those in the normal cycle. However, T and A levels rise from the very beginning of clomiphene therapy and continue to rise throughout the clomiphene-induced ovulatory cycle. Levels of E and P are higher than in the normal ovulatory cycle, but a similar pattern is preserved. Because of the potential dangers of gonadotropin therapy, monitoring by frequent examination and laboratory tests is required. E monitoring is mandatory to evaluate follicular maturation, to time hCG administration, and to minimize hyperstimulation. Cervical mucus is an unreliable parameter for monitoring gonadotropin therapy alone. In addition to cervical mucus, plasma or urinary E should be monitored regularly. Clomiphene therapy is less dangerous than gonadotropin therapy. Because of its lesser risk, monitoring is rarely performed during clomiphene use. An active monitoring approach has been described. While this approach may not necessarily improve the outcome of clomiphene therapy, it may hasten the process of selecting the appropriate dose. Although other ovulation-inducing agents are available, their use is rarely associated with serious medical complications, and monitoring would seem unnecessary.

Cervix Mucus↗

Pediatric follow-up of a randomized controlled trial of intrapartum fetal monitoring techniques.

A controlled prospective study was conducted to evaluate possible effects of the use of three intrapartum fetal monitoring techniques on the offspring of high-risk mothers in labor after at least 34 weeks' gestation. Six hundred and ninety women were randomly assigned to one of the three monitoring groups: auscultation alone, electronic monitoring alone, and electronic monitoring with option to obtain fetal scalp pH. There were no significant differences among the three groups of offspring with respect to neonatal mortality or morbidity, Apgar scores, cord blood gas values, or Brazelton examinations at ages 2 to 3 days. Assessment of the infants at 9 months revealed no significant differences in their growth and development as assessed by physical examination. Bayley Scales of Infant Development, and Milani-Comparetti tests. The frequency of delivery by cesarean section was significantly higher in the electronically monitored group than in the auscultated group. This study failed to show beneficial effects of electronic fetal monitoring over auscultated monitoring for high-risk but relatively mature fetuses.

Clinical Trials as Topic↗

Frequency and timing of recurrent events in infants using home cardiorespiratory monitors.

OBJECTIVE: To determine the incidence, type, timing, and factors predictive of recurrent significant events in infants with home cardiorespiratory monitors. STUDY DESIGN: We reviewed data accumulated for 147 patients with an event-recorder type of monitor. The infants were allocated to one of four diagnostic categories: apparent life-threatening events (ALTE, n = 73), former premature infants with persistent apnea and bradycardia (n = 29), siblings of victims of sudden infant death syndrome (SIDS) (n = 24), and parental anxiety after a nonsignificant event (n = 21). RESULTS: Compliance with monitoring was excellent; the monitors were used on 94% of the prescribed days. Fifty-three (36%) of 147 infants had significant events; of those, 46 (87%) experienced their first event during the first month of monitoring, and 69% of the events occurred during that first month. The most prevalent event type was a bradycardic event. Among infants in the ALTE group, events during the initial investigation period predicted the likelihood of events at home; 2 of the 47 infants (4%) with negative results for an investigation and no events recorded in hospital had apnea, and 4 had a bradycardic event (9%). In contrast, when significant events were recorded in hospital, the events were likely to recur at home (69% and 35% of the infants had apnea or bradycardia, respectively; p < 0.001). CONCLUSION: Because most apnea, bradycardia, and recurrent clinical events began during the first month of monitoring, we emphasize the need for vigilant follow-up care of infants immediately after institution of home monitoring. Readmission for investigation is warranted in infants with severe or multiple recurrent events.

Anxiety↗

[Blood pressure differences between consecutive days of ambulatory monitoring in hypertensive patients: the ABPM effect].

BACKGROUND: Ambulatory blood pressure monitoring is a method of blood pressure assessment that compensates for some of the limitations of office values. While a white-coat pressor effect on conventional determination has been defined and frequently used for the improved evaluation of hypertensive patients, there is no evidence that the ambulatory technique could also influence blood pressure. PATIENTS AND METHOD: Aimed at testing and quantifying the extent and duration over time of a possible pressor effect due to ambulatory monitoring, we studied 387 mild-to-moderate hypertensive patients (160 men), aged 54.2 (14.3) (mean [SD]). Blood pressure and heart rate were measured at 20-min intervals during the day and at 30-min intervals at night for 48 consecutive hours, and physical activity was simultaneously evaluated at 1-min intervals by means of a wrist actigraph. One third of patients were evaluated twice or more times. RESULTS: In hypertensive patients who were evaluated for the first time, results indicate a highly significant (p < 0.001) reduction, in the second day of monitoring as compared to the first, in the diurnal mean of systolic and diastolic blood pressure, but not in heart rate or physical activity. This pressor effect remains significant for at least the first 5 hours of monitoring. The nocturnal mean of blood pressure was, however, similar in the two days of sampling. This ambulatory monitoring effect could not be observed when patients were evaluated following the same sampling scheme at the second or further times. CONCLUSIONS: Ambulatory monitoring for 48 consecutive hours reveals a statistically significant pressor response that could reflect a novelty effect in the use of the monitoring device for the first time. This effect has notable implications in both research and clinical daily practice, both for proper diagnosis of hypertension and evaluation of treatment efficacy.

Adult↗

Cost-minimization analysis of domiciliary antenatal fetal monitoring in high-risk pregnancies.

OBJECTIVE: To compare safety and cost-effectiveness of domiciliary antenatal fetal monitoring (cardiotocography and obstetric surveillance) with in-hospital monitoring in high-risk pregnancies. METHODS: From September 1992 to June 1994, 150 consecutive women with high-risk pregnancies, who would otherwise be monitored in the hospital, entered a randomized controlled trial of in-hospital (n = 74) or domiciliary (n = 76) monitoring. The main outcome measures were neonatal safety (Prechtl neurologic optimality score, the proportion of non-optimals) and cost-effectiveness. To test a two-point difference in mean Prechtl scores (two-tailed o = .05. 1-beta = .80), 150 women were needed. Safety and cost-effectiveness were analyzed according to intention to treat. Conditional on the safety outcomes, a cost-minimization analysis based on actual resource use was performed. Uncertainty of results was explored by sensitivity analyses. RESULTS: Neonatal outcomes were equal. No cost-shifting between the antenatal and postpartum period occurred. Substituting domiciliary for in-hospital monitoring reduced mean (standard deviation) antenatal costs from $3558 ($2841) to $1521 ($1459) per woman (P < .001). If costs were varied by the addition of 50%, costs were still reduced. The magnitude of the reduction was sensitive to the costs of hospital care and less sensitive to the costs of domiciliary monitoring. CONCLUSION: Domiciliary monitoring is safe and reduces costs by one-half. The technique seems transferable to other settings but local circumstances may sometimes hamper its dissemination.

Adult↗

Accuracy of a portable prothrombin time monitor (Coagucheck) in patients on chronic oral anticoagulant therapy: a prospective multicenter study.

A portable prothrombin time (PT) monitor allows patients on oral anticoagulant therapy (OAT) to measure their PT at home. The purpose of the study was to evaluate the accuracy and precision of a portable PT monitor (Coagucheck, Roche Diagnostics, Mannheim, Germany) as compared with laboratory methods. The prospective study was conducted in four centers of the Italian Federation of Anticoagulation Clinics. A one-month instruction phase was followed by a six-month surveillance phase. Seventy-eight subjects on stable OAT (48 men, 30 women, age range: 18-75) were selected on a volunteer basis. Dual measurements of INR values were performed in each subject both from finger capillary blood by the monitor and from venous blood by the Anticoagulation Clinic laboratory in three instruction sessions. The mean difference (bias) of the monitor INR results when compared with the average of laboratory INR and monitor INR results was -0.025 (limits of agreement-LA: -0.84/+0.81 INR units). The mean bias was -0.0675 (LA: -0.37/+0.23), +0.018 (LA: -0.39/+0.35), and +0.039 (LA: -0.49/+0.55), respectively, for INR values lower than 2.0, between 2.0 and 3.0, and greater than 3.0. The overall precision coefficient of monitor INR was 0.370, while it was 0.23, 0.46, 0.29, and 0.21, respectively, in Centers 1, 2, 3, and 4. The overall variation coefficient was 6.5% while it was 3.7%, 8.5%, 4.7%, and 4.9%, respectively, in Centers 1, 2, 3, and 4. Coagucheck has an acceptable level of accuracy for INR values in the range between 2.0 and 3.0. A wide variation in monitor performance was found among centers.

Administration, Oral↗

Pilot study of a Web-based compliance monitoring device for patients with congestive heart failure.

BACKGROUND: Web-based home care monitoring systems can assess medication compliance, health status, quality of life, and physiologic parameters. They may help overcome some of the limitations associated with current congestive heart failure management models. OBJECTIVES: This pilot study compared the effects of a self-care and medication compliance device, linked to a Web-based monitoring system, to the effects of usual care alone on compliance with recommended self-care behaviors; medication taking; quality of life; distance walked during a 6-minute walk test; and New York Heart Association Functional Class. We also assessed patient experiences living with the compliance device. METHODS: We enrolled 18 patients with Functional Class II-III congestive heart failure in an urban VA Medical Center. The patients were randomized into 2 groups. Group A received usual care plus the compliance device. Group B (controls) received usual care only. Data were collected using the compliance device, the Heart Failure Self-Care Behavior Scale, pill counts, 6-minute walk test, and the Minnesota Living with Heart Failure Questionnaire at baseline and at 3 months follow-up. RESULTS: At baseline and at 3 months, there were no differences between the compliance device group and the usual care group in self-care behaviors, pill counts, 6-minute walk-test distance, or Functional Class. However, quality of life improved significantly from baseline to 3-month follow-up (ANOVA, P =.006). This difference was due to an improvement in quality of life for the monitor group (P =.002) but not the usual care only group (P =.113). Patients in the compliance device group had a 94% medication compliance rate, 81% compliance with daily blood pressure monitoring, and 85% compliance with daily weight monitoring as compared to 51% for blood pressure monitoring and 79% for weight monitoring in the usual care group (P = NS). CONCLUSION: These are promising pilot results that, if replicated in a larger sample, may significantly improve care and outcomes for patients with heart failure.

Aged↗

Monitored anesthesia care for enucleations and eviscerations.

OBJECTIVE: To report the technique and success of using monitored anesthesia care instead of general anesthesia for ocular enucleation and evisceration surgeries. DESIGN: Retrospective, noncomparative interventional case series. PARTICIPANTS: Twelve enucleated patients (Soparkar and Patrinely) and 146 eviscerated patients (Kulwin and Kersten). METHODS: Surgical logs of two oculoplastic practices were reviewed searching for cases of ocular enucleations and eviscerations performed under monitored anesthesia care between 1990 and 2001. Identified hospital and clinic charts were then reviewed. MAIN OUTCOME MEASURES: Monitored anesthesia care was deemed successful if (1) there were hemodynamic stability and complete analgesia intraoperatively; (2) there was absence of any chart documentation regarding patient or family psychological distress over the anesthesia method used; and (3) patients were discharged from the hospital without the need for observation or treatment > or = 23 hours. RESULTS: Between 1990 and 2001, 146 eviscerations were performed under local anesthesia with monitored anesthesia care by two surgeons (RCK, DRK) as their routine practice pattern. In 1996, Drs. Soparkar and Patrinely began performing enucleations under monitored anesthesia care in selected cases, and from 1996 to 2001, these surgeons enucleated 12 patients under monitored anesthesia care. Four of the enucleated patients requested surgery without general anesthesia. The remaining eight patients had been refused surgery by at least one other specialist because of the patient's perceived high medical risk for complications under general anesthesia. In all 158 patients, the procedures were deemed successful by the preceding criteria. CONCLUSIONS: This four-surgeon case series reports the successful use of local anesthesia with monitored care for ocular enucleation and evisceration procedures, offering several potential advantages over the traditional use of general anesthesia.

Adolescent↗

Epidemiology and determinants of blood glucose self-monitoring in clinical practice.

The aim of this study was to describe the epidemiology of self-monitoring of blood glucose and to identify specific characteristics of those subgroups of diabetic patients treated with insulin that are most likely to monitor their blood glucose according to medical recommendations. Data were collected on 1384 insulin-treated patients, enrolled from 35 diabetic outpatient clinics and 49 general practitioners' offices between December 1993 and June 1994. Seventeen Italian regions out of 20 were included in the study. Our data show that 418 (31%) diabetic patients treated with insulin had never practised blood glucose self-monitoring. In addition, only 242 patients (18.2%) self-monitored their glycemia with a mean frequency of at least once a day (29.7% among insulin-dependent diabetes mellitus (IDDM) and 13.9%, among insulin-treated non-insulin-dependent diabetes mellitus (NIDDM-IT) patients). Patients' characteristics associated with a higher probability of practising blood glucose self-monitoring were age below 50 years, being treated at a diabetic outpatient clinic, hypertension, need of three or more insulin injections per day, history of hypoglycemic episodes, ability to self-manage insulin doses. Our study calls for vigorous efforts aimed at promoting the incorporation of clearly-defined educational programs at each level of care, in order to improve the motivation and self-care of diabetic patients. Furthermore, studies are necessary to identify subgroups of diabetic patients that truly need to self-monitor blood glycemia, and to assess the efficacy of the practice of self-monitoring of blood glucose in improving metabolic control and reducing acute and long-term diabetic complications.

Aged↗

Three-dimensional spatial variability of chemical properties around a monitored waste emplacement tunnel.

Regulatory requirements and scientific needs require that the response of the geological system to emplacement of high level radioactive waste be monitored for long time periods. This monitoring activity is intended to establish the extent to which predicted behavior matches the actual response of the geological system to waste emplacement. To accomplish this goal, field measurements must be made at a spatial resolution that will determine whether the changes in parameters that are monitored conform to predicted evolutionary patterns. From the perspective of thermohydrological and geochemical parameters, key measurements will consider pore water compositional evolution and changes in matrix and fracture saturation in the near vicinity of waste emplacement tunnels. A massively parallel high performance computational platform (a 1200 processor IBM SP-2) was used to conduct three-dimensional, high resolution simulations to ascertain the spatial variability to be expected during a monitoring period. The results show that spatial variability in certain chemical parameters below waste emplacement tunnels provides robust targets for monitoring, but will require sampling on the scale of 10 s of centimeters in some locations, in order to rigorously test models. Chemical variability induced by relatively small changes in waste package heat output suggests that designing a monitoring program that will rigorously test model predictions will likely require high resolution, three-dimensional simulations of the "as-built" monitoring tunnels.

Environmental Monitoring↗

Evaluation of three intraoperative auditory monitoring techniques in acoustic neuroma surgery.

OBJECTIVE: To assess the efficacy of three intraoperative auditory monitoring techniques: auditory brainstem response (ABR), electrocochleography (ECoG), and direct eight nerve monitoring (DENM). STUDY DESIGN: A retrospective review of the intraoperative recordings of ABR, ECoG, and DENM was performed. SETTING: A private, neurotologic practice. PATIENTS: Sixty-six patients with usable preoperative hearing underwent intraoperative auditory monitoring with ABR, ECoG, or DENM. INTERVENTIONS: Intraoperative auditory monitoring. MAIN OUTCOME MEASURES: Postoperative pure-tone hearing threshold and word recognition scores. RESULTS: Of the 66 patients, 16 (24%) had postoperative serviceable hearing. Five (18%) of the 28 with ABR monitoring, 3 (17%) of the 18 with ECoG monitoring, and 8 (40%) of the 20 with DENM monitoring had serviceable hearing after surgery. CONCLUSIONS: This study suggests that DENM may be more effective than ABR or ECoG, although the differences in hearing preservation rates are not statistically significant.

Adult↗

Electrophysiologic intraoperative monitoring for spine procedures.

The advent of equipment capable of performing SEPs, MEPs, and EMG in a multiplexed manner and in a timely fashion brings a new level of monitoring that far exceeds the previous basic monitoring done with SEPs only. Whether this more comprehensive monitoring will result in greater protection of the nervous system awaits future analysis. In any event, monitoring of the spinal cord with SEPs is an accepted standard of care for cases that place the spinal cord at risk. Likewise, nerve root monitoring with EMG is a widely practiced form of monitoring and shows great benefit. MEPs and reflex monitoring, which address the descending pathways and the interneuronal connections, is efficacious in detecting abnormalities that may be missed by SEPs.

Electromyography↗

Labor and delivery nurses' attitudes toward intermittent fetal monitoring.

Fetal monitoring is a routine procedure overseen by labor and delivery nurses and upon which they exert considerable influence. There is a discrepancy, however, between the type of fetal monitoring routinely used and the evidence provided by current research and professional organization recommendations. This study provides the first look at labor and delivery nurses' attitudes toward fetal monitoring in more than 20 years. A descriptive, correlational study was conducted at five southeastern Michigan hospitals to evaluate attitudes toward intermittent fetal monitoring and the effect of selected demographic variables on their attitudes. Of the labor and delivery nurses who participated (N = 145), 72.4% agreed that intermittent fetal monitoring should be the standard of care. Although 87% of the respondents stated that they were willing to provide intermittent monitoring, 53.9% indicated that nurse/patient ratios were a problem in providing this service. Nurses' attitudes were significantly influenced by education level (P = .004), and 48% were unsure about current research findings related to intermittent auscultation. Nurses have a positive attitude toward intermittent monitoring, although safe nurse/patient ratios and clear policies need to be addressed. Lack of knowledge regarding the current evidence and other barriers may contribute to intermittent auscultation not being used routinely, despite the fact that its use for women of low obstetrical risk is supported by current research and professional organizations.

Adult↗

Physical activity in children and adolescents with congenital heart disease. Aspects of measurements with an activity monitor.

The aim of the present study was to evaluate different aspects of a device designed to monitor physical activity. Measurements of different axes and placement of the monitor were tested using a treadmill with ranging increments in incline or speed. The monitor was also used to assess the level of physical activity among children and adolescents with congenital heart disease and in healthy controls at the same age. The results indicate that the monitor is a valid and reproducible instrument for measurements of physical activity. The study revealed that the level of activity was higher for healthy boys than healthy girls (p<0.0001). Boys with congenital heart disease also displayed higher values compared to girls with congenital heart disease, although the difference was not significant (p=0.067). Healthy boys revealed a significantly higher level of activity than did boys with congenital heart disease (p=0.003), but no such difference was found in girls (p=0.757). Nor were any differences found between younger and older individuals among patients with congenital heart disease. Young healthy controls, however, showed significantly higher levels of activity than their older counterparts. There were differences in activity monitored during the week, with lower activity in the weekends, but the activity on the same day in different weeks seemed stable. Neither were there any differences between measurements over whole weeks. The results indicate that the Computer Science & Application monitor is a valid instrument for assessing physical activity. The monitor may also be used, therefore, to validate the levels of physical activity level in children with congenital heart disease after medical and surgical treatment.

Adolescent↗

Analysis of ambulatory duodenogastroesophageal reflux monitoring.

Some methodological in vitro observations concerning bile reflux monitoring (Bilitec) suggested that Bilitec monitoring is underestimating reflux in an acid environment. Moreover, other studies showed that the area above the cutoff level of bilirubin absorbance would provide an adequate quantitative marker for reflux of duodenal contents. Our aim was to study whether correction for intraesophageal acidity and the area above cutoff during Bilitec monitoring affects the results and the correlation with pH measurement and esophageal lesions. In 84 patients (46 men; mean age 46 +/- 2.7 years) evaluated for suspected gastroesophageal reflux disease, we performed ambulatory 24-hr esophageal pH and Bilitec monitoring after an upper gastrointestinal endoscopy. We obtained total area, percent total time, and correction by computer software. The correction factor for bilirubin absorbance was based on literature data for acidified bile (0.06 for pH < 3.6; 0.21 for pH < 2.6). Endoscopy revealed esophagitis grade 1-2 (E1-2) and 3-4 (E3-4) in 23 and 16 patients, respectively. A progressive increase of mixed (acid + bile) reflux occurred with increasing severity of endoscopic lesions (E3-4 vs no esophagitis, P < 0.05). A pathologic Bilitec monitoring result was present in the same 35 patients before and after correction and the correlation between the pH measurement and percent time of bile reflux was not improved by correction for intraesophageal pH (r = 0.386 and r = 0.391; P < 0.05). The total area of bilirubin absorbance above 0.14 (abs x min) was 7.8 +/- 2.2 in patients without esophagitis, and 11.7 +/- 4.4 and 17.0 +/- 4.2 in the E1-2 and E3-4 groups, respectively (E3-4 vs no esophagitis, P < 0.05). The correlation between the Bilitec monitoring and pH measurement regarding percent (r = 0.427, P < 0.01) or area of time below 4 (r = 0.280, P < 0.05) was not improved by considering the area of bilirubin absorbance above the cutoff level. Correction for intraesophageal pH has only a minor effect on the results of ambulatory Bilitec monitoring. Taking into account the surface rather than the percent of time above the cutoff level for bilirubin absorbance does not improve the correlation of Bilitec with acid reflux and with esophageal lesions.

Adolescent↗

An expert system for monitor alarm integration.

OBJECTIVE: Intensive care and operating room monitors generate data that are not fully utilized. False alarms are so frequent that attending personnel tends to disconnect them. We developed an expert system that could select and validate alarms by integration of seven vital signs monitored on-line from cardiac surgical patients. METHODS: The system uses fuzzy logic and is able to work under incomplete or noisy information conditions. Patient status is inferred every 2 seconds from the analysis and integration of the variables and a unified alarm message is displayed on the screen. The proposed structure was implemented on a personal computer for simultaneous automatic surveillance of up to 9 patients. The system was compared with standard monitors (SpaceLabs PC2), using their default alarm settings. Twenty patients undergoing cardiac surgery were studied, while we ran our system and the standard monitor simultaneously. The number of alarms triggered by each system and their accuracy and relevance were compared. Two expert observers (one physician, one engineer) ascertained each alarm reported by each system as true or false. RESULTS: Seventy-five percent of the alarms reported by the standard monitors were false, while less than 1% of those reported by the expert system were false. Sensitivity of the standard monitors was 79% and sensitivity of the expert system was 92%. Positive predictive value was 31% for the standard monitors and 97% for the expert system. CONCLUSIONS: Integration of information from several sources improved the reliability of alarms and markedly decreased the frequency of false alarms. Fuzzy logic may become a powerful tool for integration of physiological data.

Blood Gas Analysis↗

Towards a long-term integrated monitoring programme in Europe: network design in theory and practice.

Long-term integrated monitoring is an important approach for investigating, detecting and predicing the effects of environmental changes. Currently. European freshwaters, glaciers, forests and other natural and semi-natural ecosystems and habitats are monitored by a number of networks established by different organisations. However, many monitoring programmes have a narrow focus (e.g. targeting individual ecosystems) and most have different measurement protocols and sampling design. This has resulted in poor integration of ecosystem monitoring at a European level, leading to some overlapping of efforts and a lack of harmonised data to inform policy decisions. The need for a consistent pan-European long-term integrated monitoring of terrestrial systems programme is recognised in the scientific community. However, the design of such a system can be problematic, not least because of the constraints imposed by the need to make maximum use of existing sites and networks. Based on the outcomes of the NoLIMITS project (Networking of Long-term Integrated Monitoring in Terrestrial Systems). this article reviews issues that should be addressed in designing a programme based on existing monitoring sites and networks. Four major design issues are considered: (i) users' requirements, (ii) the need to address multiple objectives, (iii) role of existing sites and (iv) operational aspects.

Altitude↗

Dietary restrictions during ambulatory monitoring of duodenogastroesophageal reflux.

To avoid food impaction artifacts during ambulatory bile reflux monitoring (Bilitec), some groups have allowed only a liquid diet, while others omitted the meal and postprandial periods from the analysis. Our aim was to study whether Bilitec monitoring requires the use of a liquid diet. In 40 healthy subjects and 211 consecutive patients evaluated for suspected gastroesophageal reflux disease, we performed ambulatory 24-hr esophageal pH and Bilitec monitoring. The subjects were randomized to either solid or liquid meals during the procedure. All patients underwent an upper gastrointestinal endoscopy. In healthy subjects, liquid and solid diets were followed by similar acid exposure of the distal esophagus. During bile reflux monitoring, major meal artifacts occurred in 19% of the patients using solid meals, but in none of the patients using liquid meals. With liquid meals, but not with solid meals, a progressive increase in duodenoesophageal reflux occurred with increasing severity of endoscopic lesions. With liquid meals, but not with solid meals, the prevalence of pathological exposure to duodenoesophageal reflux increased with increasing severity of endoscopic lesions. With liquid meals, the results of pH monitoring and bile reflux monitoring correlated better than with solid meals. Thus, ambulatory Bilitec monitoring requires the use of liquid meals, as the use of solid meals is associated with too many meal artifacts and a poorer correlation with acid reflux and severity of endoscopic lesions.

Adolescent↗