Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “FLUOROSCOPY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66Linked to original sources

Technical results and effects of operator experience on uterine artery embolization for fibroids: the Ontario Uterine Fibroid Embolization Trial.

PURPOSE: To document the technical results and spectrum of practice of uterine artery embolization (UAE) for fibroids in the health care setting in Canada. The effects of interventional radiologist's (IR's) experience with UAE on procedure and fluoroscopy time were also investigated. MATERIALS AND METHODS: The study involved a multicenter prospective single-arm clinical treatment trial and included the practices of 11 IRs at eight university-affiliated teaching and community hospitals. Vascular access with percutaneous femoral artery approach was followed by transcatheter delivery of polyvinyl alcohol (PVA) particles into uterine arteries with fluoroscopic guidance. Technical success, complications, procedural time, fluoroscopy time, and effects of operator experience were outcomes analyzed. RESULTS: Between November 1998 and November 2000, 570 embolization procedures were performed in 555 patients. UAE was bilaterally successful in 97% (95% CI: 95%-98%). Variant anatomy was the most common reason for failure to embolize bilaterally. The procedural complication rate was 5.3% (95% CI: 3.6%-7.4%). Of the 30 events, three involved major complications (one seizure and two allergic reactions) that resulted in additional care or extended hospital stay. Procedure time and fluoroscopy time averaged 61 minutes (95% CI; 58-63 minutes) and 18.9 minutes (95% CI; 18-19.8) and varied significantly among IRs (P <.001; P <.001). The average 27% reduction in procedure time (20 minutes; P <.001) and 24% reduction in fluoroscopy time (5.1 minutes; P <.001) with increasing UAE experience were significant. CONCLUSIONS: A high level of technical success with few complications was obtained with a variety of operators in diverse practice settings. Increased experience in UAE significantly reduced procedure and fluoroscopy time.

Adolescent↗

Real-time magnetic resonance-guided placement of retrievable inferior vena cava filters: comparison with fluoroscopic guidance with use of in vitro and animal models.

PURPOSE: To compare the precision of magnetic resonance (MR)-guided versus fluoroscopy-guided placement of retrievable inferior vena cava (IVC) filters with use of real-time MR imaging strategies optimized for each device in an in vitro model and in an animal model. MATERIALS AND METHODS: Three different retrievable IVC filters were used in this study, including the Recovery, Günther Tulip, and OptEase devices. Experiments were performed on a 1.5 T-MR system with pre-release interactive MR software. For each device, high-resolution real-time MR imaging was optimized with use of steady-state free precession and fast low-angle shot sequences with radial and cartesian trajectories and varying flip angles (10 degrees -70 degrees ) and a frame rate of 2 per second. A custom-built IVC phantom was filled with dilute gadolinium contrast agent at a concentration of 0.05 mmol/L simulating a blood T1 of 8 msec and T2 of 6 msec. Signal intensities were measured in regions of interest at the filter, the IVC lumen, and the background. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated. The sequence suited best for each device was chosen for in vitro filter placement in a custom-made IVC phantom. Each device was deployed five times each under MR and fluoroscopic guidance with use of identical techniques. Accuracy was measured as absolute deviation of the filter tip in millimeters from a target landing zone. Differences were assessed statistically with use of the paired t test. Each device was also placed in vivo in a swine model under MR guidance. RESULTS: All three IVC filters could be clearly identified and positioned under fluoroscopic and MR imaging control. A cartesian true fast imaging sequence with steady-state precession with a flip angle of 30 degrees or 50 degrees resulted in optimal SNR and CNR for all three filters. The Tulip filter created more susceptibility artifacts than the other two. Filter placement accuracy was similar with MR and fluoroscopy whether comparing devices individually (P=NS) or as a group (P=NS). The mean absolute differences between MR and fluoroscopy were 0.088 mm for the OptEase filter, 0.41 mm for the Bard Recovery filter, and 0.34 mm for the Günther Tulip filter. CONCLUSIONS: MR-guided placement of retrievable IVC filters is feasible and as accurate as fluoroscopy-guided placement in an in vitro model. With optimized sequences, real-time MR has the potential to develop as a reasonable alternative to fluoroscopy.

Animals↗

Threshold contrast detail detectability measurement of the fluoroscopic image quality of a dynamic solid-state digital x-ray image detector.

Solid-state digital x-ray imaging detectors of flat-panel construction will play an increasingly important role in future medical imaging facilities. Solid-state detectors that will support both dynamic (including fluoroscopic) and radiographic image recording are under active development. The image quality of an experimental solid-state digital x-ray image detector operating in a continuous fluoroscopy mode has been investigated. The threshold contrast detail detectability (TCDD) technique was used to compare the fluoroscopic imaging performance of an experimental dynamic solid-state digital x-ray image detector with that of a reference image intensifier television (IITV) fluoroscopy system. The reference system incorporated Plumbicon TV. Results were presented as a threshold detection index, or H(T)(A), curves. Measurements were made over a range of mean entrance air kerma (EAK) rates typically used in conventional IITV fluoroscopy. At the upper and mid EAK rate range (440 and 220 nGy/s) the solid-state detector outperformed the reference IITV fluoroscopy system as measured by TCDD performance. At the lowest measured EAK rate (104 nGy/s), the solid-state detector produces slightly inferior TCDD performance compared with the reference system. Although not statistically significant at this EAK rate, the difference will increase as EAK is lowered further. Overall the TCDD results and early clinical experiences support the proposition that a current design of dynamic solid-state detector produces image quality competitive with that of modern IITV fluoroscopy systems. These findings encourage the development of compact and versatile universal x-ray imaging systems based upon solid-state detector technology to support R & F and vascular/interventional applications.

Biophysical Phenomena↗

Comparison of four methods for assessing patient effective dose from radiological examinations.

Three methods of indirect effective dose estimation were reviewed and compared to a direct effective dose determination method. An anthropomorphic phantom and thermoluminescence dosimetry were used to obtain dosimetric data associated with anterior-posterior (AP) abdominal radiography, posterior-anterior (PA) chest radiography, PA head radiography, and AP heart fluoroscopy. Effective dose was determined using: (i) organ specific dose values directly determined by thermoluminescence dosimeters, (ii) data published by National Radiological Protection Board (NRPB) and entrance surface dose (ESD), (iii) NRPB data and dose area product (DAP), (iv) energy imparted derived from DAP. The effective dose values estimated from the Rando phantom measurements were 161, 32.3, and 8.4 microSv/projection for the abdomen, chest, and head radiographs, respectively. Cardiac fluoroscopy yielded an effective dose value of 111 microSv/min. The effective dose values obtained indirectly using NRPB data and DAP were in good agreement with directly assessed values in all simulated exposures (difference <8%). The effective doses using NRPB data and ESD values differed from directly assessed values by less than 15% for the radiographic exposures and 60% for heart fluoroscopy. The energy imparted method yielded 136, 31, and 6.6 microSv/projection for the abdomen, chest, and head radiographs, respectively, and 111 microSv/min for heart fluoroscopy. Indirect patient effective dose determination using the NRPB dosimetric data and the measured value of incident radiation allows for reliable patient effective dose estimates. The use of DAP rather than ESD is recommended because it yields accurate results even for complex radiologic exposures involving fluoroscopy. The value of energy imparted may be used for the accurate determination of patient effective dose, especially when specific organ dose values are not of interest. The calculation of energy imparted with the use of EAP provides a reliable starting point for estimation of effective dose from radiologic examinations for which dosimetric data are not provided by NRPB.

Abdomen↗

Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system.

We report on initial patient studies to evaluate the performance of a commercial respiratory gating radiotherapy system. The system uses a breathing monitor, consisting of a video camera and passive infrared reflective markers placed on the patient's thorax, to synchronize radiation from a linear accelerator with the patient's breathing cycle. Six patients receiving treatment for lung cancer participated in a study of system characteristics during treatment simulation with fluoroscopy. Breathing synchronized fluoroscopy was performed initially without instruction, followed by fluoroscopy with recorded verbal instruction (i.e., when to inhale and exhale) with the tempo matched to the patient's normal breathing period. Patients tended to inhale more consistently when given instruction, as assessed by an external marker movement. This resulted in smaller variation in expiration and inspiration marker positions relative to total excursion, thereby permitting more precise gating tolerances at those parts of the breathing cycle. Breathing instruction also reduced the fraction of session times having irregular breathing as measured by the system software, thereby potentially increasing the accelerator duty factor and decreasing treatment times. Fluoroscopy studies showed external monitor movement to correlate well with that of the diaphragm in four patients, whereas time delays of up to 0.7 s in diaphragm movement were observed in two patients with impaired lung function. From fluoroscopic observations, average patient diaphragm excursion was reduced from 1.4 cm (range 0.7-2.1 cm) without gating and without breathing instruction, to 0.3 cm (range 0.2-0.5 cm) with instruction and with gating tolerances set for treatment at expiration for 25% of the breathing cycle. Patients expressed no difficulty with following instruction for the duration of a session. We conclude that the external monitor accurately predicts internal respiratory motion in most cases; however, it may be important to check with fluoroscopy for possible time delays in patients with impaired lung function. Furthermore, we observe that verbal instruction can improve breathing regularity, thus improving the performance of gated treatments with this system.

Diaphragm↗

New automated fluoroscopic systems for pediatric applications.

Pediatric patients are at higher risk to the adverse effects from exposure to ionizing radiation than adults. The smaller sizes of the anatomy and the reduced X-ray attenuation of the tissues provide special challenges. The goal of this effort is to investigate strategies for pediatric fluoroscopy in order to minimize the radiation exposure to these individuals, while maintaining effective diagnostic image quality. Modern fluoroscopy systems are often entirely automated and computer controlled. In this paper, various selectable and automated modes are examined to determine the influence of the fluoroscopy parameters upon the patient radiation exposures and image quality. These parameters include variable X-ray beam filters, automatic brightness control programs, starting kilovolt peak levels, fluoroscopic pulse rates, and other factors. Typical values of radiation exposure rates have been measured for a range of phantom thicknesses from 5 cm to 20 cm of acrylic. Other factors that have been assessed include spatial resolution, low contrast discrimination, and temporal resolution. The selection menu for various procedures is based upon the examination type, anatomical region, and patient size. For pediatric patients, the automated system can employ additional filtration, special automatic brightness control curves, pulsed fluoroscopy, and other features to reduce the patient radiation exposures without significantly compromising the image quality. The benefits gained from an optimal selection of automated programs and settings for fluoroscopy include ease of operation, better image quality, and lower patient radiation exposures.

Artificial Intelligence↗

Vascular guide wire navigation with a magnetic guidance system: experimental results in a phantom.

PURPOSE: To investigate the efficacy of a second-generation prototype magnetic guidance system in complex vessel phantoms versus conventional navigation in simulated interventional radiology procedures and to analyze procedure and fluoroscopy times. MATERIALS AND METHODS: The magnetic guidance system consists of two focused-field permanent magnets on each side of the body that create a 0.1-T navigation field and is integrated with a modified C-arm single-planar digital angiography system. Forty-nine navigations in a glass phantom and 80 navigations in a three-dimensional liver phantom were performed with a magnetically tipped floppy 0.014-inch guide wire and a conventional 0.014-inch microcatheter system. Rates of success and fluoroscopy and procedure times were quantified for both techniques. For the liver phantom experiment, the Mann-Whitney U test was used. For the glass phantom experiment, the Wilcoxon matched pair test was used with the Hodges-Lehmann estimator. RESULTS: In the glass phantom experiments, 42 of 49 turns were successfully performed with both methods. Procedure time to reach a target did not differ significantly between methods, while fluoroscopy time was significantly different when compared with that of the magnetic guidance system (P <.01). Navigation in the liver phantom was successful in 80 of 80 turns with the magnetic guidance system and in 76 of 80 turns with conventional navigation. With the support of the magnetic guidance system, procedure time and fluoroscopy time were significantly different from those with conventional navigation (P <.001). CONCLUSION: The magnetic guidance system allows the precise navigation of a magnetic guide wire in complex vessel phantoms with significantly shorter fluoroscopy and procedure times.

Angiography, Digital Subtraction↗

Assessing cervical spine stability in obtunded blunt trauma patients: review of medical literature.

PURPOSE: To review the current medical literature on dynamic fluoroscopic and magnetic resonance (MR) imaging assessment of cervical spine stability in obtunded patients who sustained blunt trauma. MATERIALS AND METHODS: The English-language literature within the Swetswise and Medline databases was searched for articles describing dynamic fluoroscopic or MR imaging assessment of cervical spine stability in patients who sustained blunt trauma. Patients with fractures or radiographic signs of injury were excluded. The frequencies of purely ligamentous injuries, injuries requiring immobilization, and other clinically important nonligamentous abnormalities were determined. RESULTS: The frequency of isolated cervical ligamentous injuries diagnosed with dynamic fluoroscopy, as reported in the literature, was 0.9% (11 of 1166 patients), whereas the reported frequency of these injuries diagnosed with MR imaging was 22.7% (125 of 550 patients). All injuries diagnosed with dynamic fluoroscopy and 101 (80.8%) of those diagnosed with MR imaging required continued cervical immobilization. Six (60%) of 10 injuries diagnosed with dynamic fluoroscopy and seven (5.6%) of 125 injuries diagnosed with MR imaging required surgical or halo stabilization. Five (2.5%) of the 200 obtunded patients assessed with MR imaging and six (0.5%) of the 1166 obtunded patients evaluated with dynamic fluoroscopy required surgery. CONCLUSION: Review of the current medical literature provided no clear evidence of the superiority of either MR imaging or dynamic fluoroscopy in the diagnosis of unstable ligamentous injury, although other relative advantages of MR imaging indicate that it is preferred for assessing cervical spine stability in obtunded blunt trauma patients.

Cervical Vertebrae↗

Mediastinal lymphadenopathy: diagnostic yield of transbronchial mediastinal lymph node biopsy with CT fluoroscopic guidance-initial experience.

PURPOSE: To determine whether the use of computed tomographic (CT) fluoroscopy to guide transbronchial needle aspiration (TBNA) of mediastinal lymph nodes can improve the diagnostic yield. MATERIALS AND METHODS: CT fluoroscopy was used to guide TBNA in 12 consecutive patients with mediastinal lymphadenopathy who had previously undergone nondiagnostic conventional TBNA. CT fluoroscopy was used to confirm the location of the biopsy needle by using a "quick-check" technique (ie, fluoroscopy was performed sparingly after needle insertion). The location of each needle, the total procedural and fluoroscopic times, and any complications were recorded. RESULTS: All CT fluoroscopic procedures were performed in less than 1 hour, and a tissue diagnosis was established in all patients. Eighteen lymph nodes with a diameter of 0.8-2.4 cm were sampled with 116 needle passes. CT fluoroscopy documented inadequate positioning in 48 of the 116 (41.3%) needle passes. Eighteen (15.5%) needles did not fully penetrate the tracheobronchial tree. Six needles (5.2%) were placed into the great vessels. Malignant disease was diagnosed in nine patients, and benign disease was diagnosed in three. The mean fluoroscopic exposure time was 20.5 seconds +/- 12.7. No pneumothoraces or substantial hemorrhage were observed. CONCLUSION: CT fluoroscopic guidance for TBNA procedures is a safe and efficient means of providing diagnostic material and should be considered for patients who have previously undergone nondiagnostic blinded TBNA.

Adult↗

Digital radiography of scoliosis with a scanning method: initial evaluation.

PURPOSE: To evaluate the radiation dose, image quality, and Cobb angle measurements obtained with a digital scanning method of scoliosis radiography. MATERIALS AND METHODS: Multiple images were reconstructed into one image at a workstation. A low-dose alternative was to use digital pulsed fluoroscopy. Dose measurements were performed with thermoluminescent dosimeters in an Alderson phantom. At the same time, kerma area-product values were recorded. A Monte Carlo dose calculation also was performed. Image quality was evaluated with a contrast-detail phantom and visual grading system. Angle measurements were evaluated with an angle phantom and measurements obtained on patient images. RESULTS: The effective radiation dose was 0.087 mSv for screen-film imaging, 0.16 mSv for digital exposure imaging, and 0.017 mSv for digital fluoroscopy; the corresponding kerma area-product values were 0.43, 0.87, and 0.097 Gy. cm(2), respectively. The image quality of the digital exposure and screen-film images was about equal at visual grading, whereas fluoroscopy had lower image quality. The angle phantom had lower angle values with digital fluoroscopy, although the difference in measured angles was less than 0.5 degrees. The patient images showed no difference in angles. CONCLUSION: The described digital scanning method has acceptable image quality and adequate accuracy in angle measurements. The radiation dose required for digital exposure imaging is higher than that required for screen-film imaging, but that required for digital fluoroscopy is much lower.

Fluoroscopy↗

Endobronchial ultrasound-guided transbronchial lung biopsy in solitary pulmonary nodules and peripheral lesions.

Transbronchial biopsy (TBBX) for peripheral lung lesions is usually performed with the help of fluoroscopy, but the yield varies widely. This feasibility study aimed to assess the ability of endobronchial ultrasound (EBUS) to provide imaging guidance for TBBX. In a prospective study, 50 consecutive patients referred for TBBX for peripheral lesions underwent fluoroscopy-guided and EBUS-guided TBBX in random order. Diagnostic yields were compared for both modalities and feasibility was assessed for EBUS. Diagnostic material was obtained in 80% of patients with EBUS and 76% of patients with fluoroscopy. There was a nonsignificant trend for EBUS to be better than fluoroscopy for lesions <3 cm in diameter. Four lesions could not be visualised with EBUS. There were no significant complications associated with the use of EBUS. Endobronchial ultrasound-guided transbronchial biopsy is feasible. It appears to be at least equivalent to fluoroscopy without the accompanying radiation exposure. Further large-scale studies are indicated to assess the possible role of endobronchial ultrasound as a potential imaging method of choice for the biopsy of peripheral lung lesions.

Adult↗

Radiation exposure and efficacy of exposure-reduction techniques during cardiac catheterization in children.

OBJECTIVE: The purpose of this study was to measure radiation exposure levels in children undergoing cardiac catheterization. This information was used to assess methods of reducing exposure and to characterize total exposures. SUBJECTS AND METHODS: The radiation exposure area product was determined for a total of 175 patients during three study intervals over 10 years. Examinations included biplane fluoroscopy and cineangiography for the diagnosis and treatment of congenital heart disease. RESULTS: The use of pulsed progressive fluoroscopy was found to reduce patients' fluoroscopic exposure rates by approximately 40% as compared with interlaced mode fluoroscopy. Combining exposures from the frontal and lateral projections, the median fluoroscopic time for diagnostic procedures was 21 min and the median time for cineangiography was 42 sec. Median total exposure area product was 2063 R-cm2 with cineangiography accounting for 44% of the total exposure. For an estimated X-ray beam entrance area of 50-100 cm2, the median total entrance exposure was in the range of 20-40 R. Fluoroscopy times for interventional procedures were found to be 1.5 to 2.5 times longer than for diagnostic procedures, with total exposures approximately three times higher. CONCLUSION: This study suggests that pulsed progressive fluoroscopy is an effective method of reducing radiation exposure in children undergoing cardiac catheterization.

Adolescent↗

Significantly reduced radiation exposure to operators during kyphoplasty and vertebroplasty procedures: methods and techniques.

BACKGROUND AND PURPOSE: Vertebroplasty and kyphoplasty can be associated with significant radiation exposure to the operator. We compared the exposure levels to an operator performing vertebral fracture augmentation with vertebroplasty and kyphoplasty, to assess a cement injection and a monitoring technique designed to reduce this exposure. METHODS: A neuroradiologist performed 189 consecutive vertebral augmentation procedures in 135 patients with osteoporotic compression fractures by using a bilateral approach with biplane pulse fluoroscopy at 7.5 pulses/second. Cement delivery was performed with intermittent fluoroscopy with kyphoplasty and vertebroplasty by using syringes or continuous fluoroscopic monitoring with a cement delivery system (CDS). Data collection included time and operator exposure parameters. RESULTS: A total of 87 kyphoplasty procedures, 82 vertebroplasty procedures with a CDS (VP-CDS), and 20 vertebroplasty procedures with syringes (VP-S) were safely performed. Mean fluoroscopy time for device positioning was 4.3 minutes for each procedure type. Mean fluoroscopy time (minutes) for cement delivery was significantly different for the 3 procedure types; 2.1 for kyphoplasty, 3.7 for VP-CDS, and 1.5 for VP-S (P < .0001). Comparable mean radiation exposure rates (microsieverts/minute) were 0.8 for kyphoplasty, 1.1 for VP-CDS, and 0.3 for VP-S during device-positioning and 1.7 for kyphoplasty, 2.9 for VP-CDS, and 0.2 for VP-S during cement injection (P < .002). CONCLUSION: Use of the modified cement injection technique and intermittent fluoroscopy with kyphoplasty and vertebroplasty with syringes results in a significantly lower operator exposure rate compared with vertebroplasty with a CDS.

Adult↗

[Diaphragm kinetics coupled with spirometry. M-mode ultrasonographic and fluoroscopic study; preliminary results].

Most techniques used so far for the evaluation of diaphragm kinetics are either invasive (electromyography, fluoroscopy), or indirect (respiratory pressures, impedance plethysmography). The aim of this study was to determine whether assessment with ultrasound or fluoroscopy differed, and which technique appeared more suitable in the investigation of quantitative hemidiaphragmatic displacement. Six patients (3 female, 3 male, aged 29 to 40) without respiratory disease were studied during systematic X-Ray chest examination, spirometry, and abdominal sonography. The amplitude of the right diaphragm motion could be measured in all patients with M-mode sonography as well as with fluoroscopy. The vertical ascending motion of the diaphragm measured by M-mode sonography, reached 60% of its maximum amplitude at 50% of inspiratory capacity. There was a significant correlation between the maximum amplitude of diaphragm motion as measured by M-mode sonography (5.8 +/- 0.4 cm; r = 0.89; p = 0.019) or fluoroscopy (5.6 +/- 0.7 cm; r = 0.84; p = 0.036) and the inspiratory capacity (2.73 +/- 0.39 l). M-mode sonography has technical, quantitative and qualitative advantages over fluoroscopy and should be the method of choice in the investigation of suspected diaphragmatic movement disorder. When coupled with other techniques like spirometry, this technique could represent a useful adjunct to functional respiratory studies.

Adult↗

Treatment of small hepatocellular carcinoma with acetic acid percutaneous injection.

UNLABELLED: Percutaneous ablation using acetic acid is an attractive method because of its low morbidity and low number of sessions required to induce complete tumor necrosis. Moreover, the real-time fluoroscopy CT scan could improve the technique by improving distribution of the necrotizing agent within the tumor. AIM: To determine the feasibility and the long-term results of the acetic acid percutaneous injection under CT fluoroscopy guidance in a series of cirrhotic patients with small hepatocellular carcinoma in a single French center. METHODS: One hundred and two patients with hepatocellular carcinoma were evaluated for treatment between 1999 and 2000. The selection criteria for fluoroscopy CT scan-directed percutaneous acetic acid ablation were: 1) one to three nodules<5 centimeters; 2) Child-Pugh class<13; 3) prothrombin index > 40% and platelet count > 50000 per mm(3) and 4) contraindication to both resection and liver transplantation. Post treatment follow-up included ultrasonography, magnetic resonance and alphafetoprotein levels every 3 months. Recurrence and survival rates were estimated using the Kaplan-Meier method. RESULTS: Forty-nine patients (48%) could benefit from a curative treatment, most of them (37/49) being eligible for fluoroscopy CT scan-directed percutaneous acetic acid. The mean follow up was 24.4 +/- 2.7 months. Complete tumor necrosis was achieved in 28 patients (76%) after a mean of 1.6 sessions. In these 28 patients, the recurrence rates were 34% and 48% and survival rates were 76% and 70%, at 24 and 36 months, respectively. No serious complications occurred during or after the treatment. CONCLUSIONS: Percutaneous ablation using acetic acid using CT fluoroscopy guidance may be considered as a short term efficient, low risk treatment and can be applied even in patients with ascites or severe hemostatic abnormalities. However, the high rate of recurrence and the early occurrence of multifocal hepatocellular carcinoma underline the limits of this method as well as of all other percutaneous strategies.

Acetic Acid↗

A new nonfluoroscopic navigation system to guide pulmonary vein isolation.

Different techniques have been proposed to treat atrial fibrillation (AF) by catheter ablation. This study compares a new three-dimensional (3D) nonfluoroscopic navigation system with conventional fluoroscopy to guide pulmonary vein (PV) isolation. A total of 60 consecutive patients with paroxysmal or persistent AF were randomly assigned to 3D-guided ablation (group 1, n = 30), versus conventional fluoroscopy guidance ablation (group 2, n = 30). Complete PV isolation was achieved in both groups. The mean duration of fluoroscopy exposure (22 +/- 8 vs 56 +/- 10 minutes), and radiofrequency delivery (5 +/- 1 vs 10 +/- 3 minutes) were significantly shorter in group 1 than in group 2, P < 0.05 for both comparisons). The mean procedural time in group 1 was longer (225 +/- 15 minutes) than in group 2 (156 +/- 10 minutes, P < 0.05) due to the learning curve and time spent to generate the 3D maps. Over a mean follow-up of 7 +/- 2 months, 6 patients (20%) in group 2 had AF recurrences compared to 3 patients (10%) in group 1 (ns). The new nonfluoroscopic 3D system allows a high-resolution reconstruction of the left atrium and PVs. It significantly reduces the mean radiofrequency delivery and fluoroscopy times as opposed to ablation performed under fluoroscopy guidance.

Atrial Fibrillation↗

[Evaluation of patient entrance dose rate of interventional X-ray equipment].

Because interventional radiology (IVR) procedures are being performed with increasing frequency, patient X-ray exposure dose for X-ray fluoroscopic and radiographic procedures should not be ignored. In order to avoid excessive X-ray exposure, exposure dose rate limits are specified in the Japanese Industrial Standards (JIS) and by civil law at 50 mGy/min for usual fluoroscopy and 125 mGy/min for high-dose fluoroscopy. In the present study, we examined the difference in patient incident dose rate before and after using an X-ray generator that satisfied the above requirements. For incident dose to the image intensifier (I.I.), we investigated the differences between continuous and pulsed fluoroscopy, the effects of additional filters (Ta: tantalum, Al: aluminum), and the form of the X-ray spectrum. For pulsed fluoroscopy using PMMA (polymethyl-methacrylate), the maximum patient incident dose rates of usual and high-dose fluoroscopy were 59 mGy/min and 151 mGy/min, respectively. With regard to I.I. incident dose, saturation was observed beginning at a PMMA of 20 cm, and the X-ray dose was insufficient. In terms of the difference in patient incident dose rate with Ta and Al filters, the dose rate with the Ta filter was approximately 50% lower than that with the Al filter except for the saturation area. Concerning the X-ray spectrum, it was considered that a Ta filter not only minimizes patient X-ray exposure (because Ta reduces soft X-rays more effectively than Al) but also minimizes scattered X-rays because it filters out hard X-rays, leading to improved image quality. However, the use of the filter is appropriate only when a sufficient I.I. incident dose can be ensured. Specifically, the use of the filter under saturation conditions can lead to deterioration in image quality. Therefore, IVR X-ray systems must be equipped with an appropriate filter for reducing X-ray exposure while maintaining a sufficient I.I. incident dose rate.

Filtration↗

Cinefluoroscopic assessment of mechanical disc prostheses: its value as a complementary method to echocardiography.

BACKGROUND AND AIM OF THE STUDY: Many types of mechanical prostheses are used for heart valve replacement, but it is difficult to distinguish between them using transthoracic echocardiography. Hence, cinefluoroscopy complements the echocardiographic evaluation of cardiac prostheses. The aims of the present study were to: (i) describe the contribution of cinefluoroscopy in identifying different prostheses; (ii) compare gradients obtained by Doppler echocardiography with the opening angle of the discs assessed by cinefluoroscopy; and (iii) assess the ability of cinefluoroscopy to distinguish normal from dysfunctional prostheses. METHODS: A total of 229 mechanical disc prostheses was prospectively evaluated with cinefluoroscopy. Eight prosthetic valves (six aortic, two mitral) were excluded due to the coexistence of severe left ventricular dysfunction. Thus, the final analysis comprised 221 prosthetic valves (146 aortic, 75 mitral). RESULTS: Based on the characteristics of the ring and the discs, cinefluoroscopy identified 87 single-leaflet and 134 bileaflet prostheses. Disc motion allowed distinction to be made between normal and dysfunctional prostheses (opening angle: 74 +/- 13 degrees versus 49 +/- 18 degrees). Fluoroscopy could not define disc profile or the ring in 6% of aortic valves and in 26% of mitral prostheses. The technique could be used to identify the TriTechnologies and HP-Biplus valves, but could not provide data on prosthetic function due to radiolucency of the discs. Among the 146 aortic prostheses, Doppler echocardiography helped to identify 109 normal valves and 37 dysfunctional valves. Among 75 mitral prostheses, 54 normal and 21 dysfunctional prosthetic valves were identified. When both methods were correlated, the sensitivity, specificity and positive and negative predictive values of fluoroscopy to distinguish normal from malfunctioning prostheses were 83%, 80%, 89%, and 71%, respectively. CONCLUSION: Each prosthesis type has radioscopic characteristics that allow its identification. Fluoroscopy permitted rapid and easy evaluation of mechanical prosthetic valve function, and in most cases allowed a distinction to be made between normal and dysfunctional prostheses. The presence of high gradients by Doppler echocardiography, with normal opening angles by fluoroscopy, and without pannus on transesophageal echocardiography, is indicative of patient-prosthesis mismatch. Fluoroscopy was superior to echocardiography in identifying disc motion, whilst Doppler study allowed the measurement of gradients and areas, and semiquantification of regurgitation. Thus, cinefluooscopy rapidly provides valuable information which is complementary to that obtained by echocardiography.

Aged↗