Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66Linked to original sources

[Determination of copper alloy hardness, in original form and after casting as a function of casting techniques].

It was evaluated the Vickers hardness of five high-copper casting alloys, in their original package form and after casting, according to the casting method used. That way, ten ingots, supplied by the manufacturers of each alloy, were included in self-curing acrylic resin, polished, numerated and submitted to Vickers hardness test at load of 200 g during 30 seconds. Afterwards the numerated ingots were removed from the acrylic resin and five of those were cast in an electrical casting machine and the other five in a centrifugal casting machine with an air/gas torch. The specimens obtained were included in self-curing acrylic resin, polished and submitted to Vickers hardness test. As a result it was verified that there is a variation of hardness among the alloys tested, and the use of the electrical casting machine produced lower hardness values than those produced when used the centrifugal casting machine with an air/gas torch. Also, there is a decrease of hardness of the cast alloys when they are tested in their original form and after casting.

Copper↗

Dynamic viscoelastic properties of models composed of posterior denture teeth and denture base resin.

The purpose of this investigation was to compare the dynamic viscoelastic properties of various models composed of denture teeth and heat-cured denture base resin. The specimens were porcelain and resin teeth mounted in denture base resin. Compressive dynamic stiffness and phase differences were measured with a viscoelastic spectrometer. Measurements of the viscoelastic frequency spectrum based on the fast Fourier transform of displacement to applied random forces were analyzed with a spectrum analyzer. The stiffness of the specimens was independent of the frequency. The stiffness of the porcelain specimens was higher than that of the resin ones measured under the same conditions. The phase lag of the specimens was dependent on the frequency. The phase lag of the porcelain specimens was lower than that of the resin ones measured under the same conditions. This study suggested that the acrylic resin teeth had greater toughness and higher shock-absorbing ability than the porcelain teeth, and that the porcelain teeth were more brittle than the acrylic resin ones, whether the teeth were isolated or in dentures.

Acrylic Resins↗

Adhesive properties of several impression material systems: Part I.

The tensile adhesive bond strength of five impression adhesive systems was studied: polysulfide, polyether, polyvinylsiloxane, condensation silicone impression, and polyvinylsiloxane putty adhesive systems. Results showed no significant difference in adhesive bond strength to autopolymerizing acrylic resin between the former four impression materials studied. Polyether and medium-viscosity polyvinylsiloxane demonstrated significantly higher adhesive bond strength to polystyrene than either polysulfide or condensation silicone. The medium-viscosity polyvinylsiloxane impression material showed significantly higher adhesive bond strength to polystyrene than autopolymerizing acrylic resin whereas polysulfide and condensation silicone impression materials adhered significantly better to autopolymerizing acrylic resin than polystyrene. The polyvinylsiloxane putty did not adhere to its impression adhesive. Variation of the speed of tensile testing between 5 to 20 inches per minutes did not affect the adhesive bond strength of a polysulfide impression material.

Adhesiveness↗

[Epoxide acrylate maleic resin and hydroxyapatite composite material as a bone graft substitute in surgical correction of orbital reconstruction].

This paper illustrates the results of surgical correction in 11 cases with orbital deformities such as periorbital deficiency after orbitotomy for retinoblastoma and orbital malposition after facial trauma. EH composite material, mixture of hydroxyapatite and epoxide acrylate maleic resin in constant proportion, was used as a good bone graft substitute in all 11 cases. This material was easier to be molded during surgery, safe to human body, had no toxic effects, no irritation and no implant-related complications. The early results obtained in these patients are encouraging.

Adolescent↗

Duplication of interim speech aid for definitive impression tray fabrication.

A wax tray is stable and easily relieved if overextended. Unusual tray undercuts or angles needed for the partial resection patient need not be eliminated before the impression procedure. Relief of these undercuts is necessary with acrylic resin trays to ensure separation from the final stone cast. Because the wax tray is separated easily from the prosthesis during the boil-out, it is not necessary to "burn" or grind acrylic resin from the framework. The tray shape is duplicated from the existing interim prosthesis on the nasopharyngeal and oropharyngeal side. An arbitrarily shaped acrylic resin tray may be grossly overextended and require time-consuming clinical adjustments. An underextended tray on the nasopharyngeal side will not carry or support the impression material around or through the residual soft palate remnant. A tray that closely approximates the final prosthesis will allow use of a tissue conditioner final impression without need for border molding (Fig. 2). Duplicating the oropharyngeal side of the interim speech aid duplicates the previously established plane that is compatible with the tongue. The author has used this technique successfully for eight total and five partial soft palate resections. A cleft palate speech aid prosthesis has also been made with this technique.

Denture Design↗

Comparative study of the marginal microleakage of six cements in fixed provisional crowns.

STATEMENT OF PROBLEM: In many situations, provisional restorations require a long-term permanence in the oral cavity. During this period, the abutments need the best possible biologic and mechanical protection. In this way, the vitality of the pulp and the integrity of mineralized tissues can be preserved. The luting cement used to fix interim restorations should have good mechanical properties, low solubility, and good adhesion to resist bacterial and molecular penetration. However, because of its provisional nature, the prosthesis should be easy to remove from the abutments. These contrasting requirements may lead to a compromise in cement behavior, particularly in its mechanical properties. PURPOSE: This in vitro study evaluated the marginal microleakage of 4 provisional cements, a cavity base compound and a zinc-phosphate luting cement in provisional acrylic resin crowns fixed on extracted human teeth. MATERIAL AND METHODS: Thirty acrylic resin crowns were made and fitted on intact human premolars with the 6 cements. All restorations were applied in a standardized manner by means of an axial load of 10 kg. Specimens were thermocycled then submerged in a 5% basic fuchsin solution, then sectioned and observed under a light stereomicroscope. A 5-level scale was used to score dye penetration in the tooth/cement interface. RESULTS: A high dye penetration in the tooth/cement interface was present in all 4 provisional cements. Microleakage existed in specimens where zinc-phosphate and cavity base compounds were used; however, it was lower than the other materials. A significant difference (P < .05) was found between zinc-phosphate and one eugenol-free cement and between cavity base and the same eugenol-free cement. CONCLUSIONS: All materials tested demonstrated different degrees of microleakage. Zinc-phosphate and cavity base compound cements had the best sealing properties. This latter, even if conceived as a cavity base, may be considered a good provisional cement as far as microleakage is concerned.

Acrylic Resins↗

Spectral fluorescence of direct anterior restorative materials.

The fluorescent characteristics of silicate cements, acrylic resins, and composite resins and all anterior restorative materials have been compared with the natural teeth when specimens were submitted to ultra-violet radiation. The effect of glazes on composite resins and of discolouration from ultra-violet radiation on composites and acrylic resins is to reduce the amount of fluorescence of the former and to change the quality of the fluorescence.

Acrylic Resins↗

An evaluation of self-cured and visible light-cured denture base materials when used as a denture base repair material.

The aim of this study was to compare some of the physical properties of a heat-cured, a self-cured and a visible light-cured acrylic resin, and to evaluate the suitability of visible light-cured resin as a repair material for dentures made of heat-cured acrylic resin. Transverse strength, surface hardness and impact strength were determined for the three materials and the efficiencies of light-cured and self-cured resins, when used as a repair material, were evaluated by testing the transverse strength of repaired heat-cured specimens 1 hour, 1 week and 1 month after repair. The results showed that the rigidity of specimens repaired with light-cured resin improved with longer water storage. However, their transverse strength reached a maximum after one day and was reduced after 1 month. The rigidity and transverse strength of specimens repaired with self-cured resin were not influenced significantly by water storage and the transverse strength was significantly higher than the light-cured repaired specimens.

Acrylic Resins↗

[Properties of experimental high abrasion resistance plastic teeth].

High abrasion resistance plastic teeth made of microfilled urethane dimethacrylate resin were developed around ten years ago. In recent years, several of this same type of resin teeth were developed and introduced commercially in Japan. Many studies have reported the properties of restorative resin materials, but few comparative studies have been conducted among the various resin teeth on the market. The purpose of this study was to compare the basic physical properties of conventional acrylic resin teeth as dental materials with an experimental high abrasion resistance plastic for posterior teeth made of microfilled urethane dimethacrylate. In addition, we compared the properties of the experimental teeth with the other high abrasion resistance plastic teeth including a comparative study of anterior and posterior teeth already on the market. The results indicated that basic physical properties of the experimental posterior resin teeth were better than those of the conventional acrylic resin teeth, but the staining resistance of the former was a little lower than that of the latter. Further, the experimental posterior teeth appeared to have physical properties equal to those of other resin teeth of the same type, but the staining resistance of the experimental resin teeth was higher.

Acrylic Resins↗

Modified finish line in distal extension maxillary removable partial dentures.

Finish line modifications provide adjustability and facilitate relining in the hamular notch as changes in tissue contour dictate. Time problems and inconvenience of dealing with a metal-acrylic resin junction, are eliminated while necessary postinsertion procedures are accomplished. In addition, the acrylic resin denture base is retained securely to the metal framework for the entire length of the external finish line.

Acrylic Resins↗

Use of LR white resin for post-embedding immunolabelling of brain tissue.

The object of this study was to investigate the applicability of the acrylic resin 'LR White' to immunolabelling of various antigenic determinants in aldehydefixed rat CNS tissue. Antibodies were used, which worked well in paraffin sections and therefore were suitable to detect antigens resistant to complete dehydration and heat. Different LR White embedding protocols were employed in order to select the preparation conditions that adequately preserved both the antigenicity and fine structure. Specimens were completely dehydrated with up to 100% ethanol, which was followed by various infiltration times with LR White monomer. Polymerization of the resin was induced by heat, a chemical catalytic procedure (accelerator), or ultraviolet (UV) light. Paraffin, as well as semithin and ultrathin LR White sections were incubated with antibodies reacting to antigens located on the cell surface (stage-specific embryonic antigen-1; SSEA-1), within the plasma membrane (myelin basic protein), in the cytosol (HNK-1, S100 protein), in the cytoskeleton (GFAP, vimentin, neurofilament protein, INT-FIL), and in the extracellular matrix (laminin). All of the examined antigens were immunocytochemically detectable in paraffin-embedded material, while the carbohydrate moieties, HNK-1 and SSEA-1, were not immunoreactive in LR White sections. However, in cryostat sections processed for pre-embedding immunoelectron microscopy, the HNK-1 epitope and SSEA-1 were immunolabelled. Polymerization carried out under UV light led to better structural preservation of brain tissue than resin cured with heat or catalyst. The length of prior infiltration with monomer apparently had no effect on tissue preservation. Consequently, UV light-induced polymerization of LR White gives acceptable morphology of brain tissue. However, the use of this acrylic resin is restricted to the detection of some CNS antigens only.

Acrylic Resins↗

The "Loma Linda stent": a screw-retained resin stent.

This article describes a technique in which an acellular dermal allograft is used in combination with a photopolymerized acrylic resin stent to increase the zone of keratinized tissue around osseointegrated dental implants. During the second-stage surgery, a split thickness labial flap is reflected and apically repositioned by being sutured onto the periosteum and connective tissue. The acellular dermal allograft is then sutured onto the recipient site. The acrylic resin is trimmed and secured with temporary abutments to the implants, fitting passively over the graft and then photopolymerized intraorally. The stent is left for 1 week to secure the graft in place. This technique offers an alternative mucogingival procedure for increasing the zone of keratinized tissue around osseointegrated dental implants.

Acrylic Resins↗

Effect of finishing and polishing procedures on the gap width between a denture base resin and two long-term, resilient denture liners.

STATEMENT OF PROBLEM: The junction between a long-term, resilient denture liner and the denture base is difficult to finish and polish due to differences in the hardness of the materials. Gaps tend to form during finishing and polishing procedures. PURPOSE: This study measured the junctional gap between 2 long-term, resilient denture liners and a denture base material after different finishing and polishing procedures were performed. The surface smoothness of the 2 liner materials also was evaluated. MATERIAL AND METHODS: Molloplast-B and an experimental, heat-polymerized methyl siloxane-resin-based denture liner were processed (according to the manufacturer's instructions) against Lucitone 199 acrylic resin. Control specimens (n = 20) were 2 mm thick and flat. Experimental specimens (n = 64) were fabricated with a raised center section: a 3- x 5- x 15-mm half-cylindrical ridge with a junction at the top of the cylinder between the liner material and acrylic resin. The specimens were finished with 1 of 6 types of burs and polished with different combinations of rubber-impregnated acrylic polishers, pumice, and tin oxide. The finished specimens were examined and photographed with a scanning electron microscope, and the largest gap along the liner/denture base junction on each specimen was measured. Three-way analysis of variance without replication (P<.05) and post-hoc t tests were used to analyze the data and compare groups. RESULTS; Averaged across finishing and polishing techniques, a larger gap was recorded for the experimental liner material (22 microm) than for Molloplast-B (14 microm) (P<.00005). Qualitative evaluation suggested that the experimental liner material polished better than Molloplast-B. The smoothest surfaces were obtained when specimens were finished with fine-tooth cross-cut carbide burs and polished with both pumice and tin oxide. A comparison between polished and unpolished specimens, averaged over materials and finishing techniques, revealed that polishing reduced gap size (P=.015). CONCLUSION: Within the limitations of this study, the 2 denture liners tested behaved similarly. The results suggest that the size of the gap at the liner/denture base junction may be affected by finishing and polishing techniques and vary among materials.

Acrylic Resins↗

Randomized controlled clinical trial on satisfaction with resilient denture liners among edentulous patients.

PURPOSE: The purpose of this study was to measure patients' satisfaction and their preference between mandibular dentures with permanent silicone-based resilient denture liner (SR) and conventional heat-activated acrylic resin (AR), both opposed by acrylic resin-based maxillary complete dentures. MATERIALS AND METHODS: Twenty-eight edentulous patients who had fulfilled selection criteria and provided informed consent were enrolled in this trial. Subjects were allocated randomly to either arm of cross-over groups (AR-SR/SR-AR), stratified by gender, using a random permuted block within the strata method. The AR-SR group received AR denture treatment followed by SR denture treatment. The SR-AR group received treatment in the reverse sequence. The primary outcome was patient satisfaction measured on 100-mm VAS, analyzed by two-way ANOVA and the Bonferroni multiple comparison as a post hoc test. The secondary outcome was patients' preference, evaluated by chi-square goodness-of-fit test. An intention-to-treat analysis was performed. RESULTS: Twenty-five subjects were enrolled in the analysis. There were no significant differences between AR and SR dentures 1, 2, and 3 months after the completion of control. Eighteen of 25 patients preferred SR dentures. CONCLUSION: Although there were no significant differences in patient satisfaction ratings between the two types of dentures, a significant majority of patients preferred those with a resilient denture liner.

Acrylic Resins↗

Laboratory fabrication of gold occlusal surfaces for removable and implant-supported prostheses.

This article describes a technique for fabricating prosthetic teeth with gold occlusal surfaces for removable or implant-supported prostheses. Following a successful wax try-in appointment, the denture teeth used in the prosthesis are invested in a denture flask. After deflasking, the gingival 2/3 of the denture teeth are trimmed away. The remaining occlusal portions of the teeth are invested in a gypsum-bonded investment and cast in a type III gold alloy. After polishing, the castings are repositioned back into their respective sites in the flask. An acrylic resin of an appropriate shade is mixed and packed in the flask. Once the acrylic resin is processed to the metal occlusal surfaces, the individual teeth are removed from the flask and polished. Then the finished teeth are reinserted in the wax trial denture, the occlusion is refined, the final wax-up is completed, and the prosthesis is processed.

Acrylic Resins↗

Long-term effects of storage and thermal cycling on the marginal adaptation of provisional resin crowns: a pilot study.

STATEMENT OF PROBLEM: Provisional resin crowns may be used for an extended period while complex treatments are completed. The crowns function intraorally; therefore, moisture absorption and thermal cycling may affect the physical properties of acrylic resin, causing a change in marginal gap size. PURPOSE: The purpose of this pilot study was to examine the effect of long-term water absorption and thermal cycling on marginal gap size of polymethyl methacrylate copolymer and bis-acrylic composite resin crowns. MATERIAL AND METHODS: Specimens (n = 10) were fabricated from 2 acrylic resins: a polymethyl methacrylate (Alike) and a bis-acrylic composite resin (Provitec). Specimens were first fabricated on a metal master die. Custom die stems were fabricated for each specimen from a low-fusing alloy (Cerroblend) to eliminate the factor of polymerization shrinkage. Specimens were then fitted to assure a standardized, pre-experimental marginal gap range of < or = 25 microm. Specimens were stored in a humidor at 37 degrees C and 97% relative humidity for 1 year and subsequently thermal cycled (5 degrees C to 60 degrees C, 6-second dwell time, for 8000 cycles). Measurements in micrometers of the marginal gap were recorded using a microscope equipped with a digital video camera and image analysis software before and after treatment. A 2-way analysis of variance with a split design was performed for factors of materials and treatment (alpha = .05). RESULTS: For the factor of material, there was no significant difference; however, there was a significant difference between treatments, with a significantly greater increase in marginal gap size after thermal cycling (P < .002). CONCLUSION: Provisional crowns made from either a bis-acrylic resin composite or a polymethyl methacrylate copolymer demonstrated loss of marginal adaptation during a simulated long-term period of service.

Acrylic Resins↗

Denture fracture--a survey.

The fracture of dentures is an unresolved problem. Despite increasing costs incurred by the nation on the repair of these prostheses, very little has been documented on the type of fracture encountered. This survey was carried out to determine the prevalence of type of fracture by the distribution of questionnaires to three different laboratories. Results obtained showed that 33% of the repairs carried out were due to debonded/detached teeth. Twenty-nine per cent were repairs to midline fractures, more commonly seen in upper complete dentures. The remaining 38% were other types of fractures, the majority of which constituted repairs to upper partial dentures. The latter involved detachment of acrylic resin saddles from the metal in metal based dentures and the fractures of connectors in the all-acrylic resin partial dentures.

Acrylic Resins↗

Restoration of Class IV and VI defects in anterior teeth with an unfilled resin.

The etched resin technique with unfilled acrylic resin has been successful for Class IV and VI defects on anterior incisor teeth and has proven more useful than alternatives in the immediate treatment of traumatized teeth. The advantages of this approach are ease of operation, excellent retention, conservative tooth preparation, excellent esthetics, lower cost to patient, reduced additional insult to recently traumatized teeth in stabilizing them, stable color, and lack of trauma to opposing teeth (Fig. 10).

Acrylic Resins↗