Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

Running over rough terrain: guinea fowl maintain dynamic stability despite a large unexpected change in substrate height.

In the natural world, animals must routinely negotiate varied and unpredictable terrain. Yet, we know little about the locomotor strategies used by animals to accomplish this while maintaining dynamic stability. In this paper, we perturb the running of guinea fowl with an unexpected drop in substrate height (DeltaH). The drop is camouflaged to remove any visual cue about the upcoming change in terrain that would allow an anticipatory response. To maintain stability upon a sudden drop in substrate height and prevent a fall, the bird must compensate by dissipating energy or converting it to another form. The aim of this paper is to investigate the control strategies used by birds in this task. In particular, we assess the extent to which guinea fowl maintain body weight support and conservative spring-like body dynamics in the perturbed step. This will yield insight into how animals integrate mechanics and control to maintain dynamic stability in the face of real-world perturbations. Our results show that, despite altered body dynamics and a great deal of variability in the response, guinea fowl are quite successful in maintaining dynamic stability, as they stumbled only once (without falling) in the 19 unexpected perturbations. In contrast, when the birds could see the upcoming drop in terrain, they stumbled in 4 of 20 trials (20%, falling twice), and came to a complete stop in an additional 6 cases (30%). The bird's response to the unexpected perturbation fell into three general categories: (1) conversion of vertical energy (EV=EP+EKv) to horizontal kinetic energy (EKh), (2) absorption of EV through negative muscular work (-DeltaEcom), or (3) converting EP to vertical kinetic energy (EKv), effectively continuing the ballistic path of the animal's center of mass (COM) from the prior aerial phase. However, the mechanics that distinguish these categories actually occur along a continuum with varying degrees of body weight support and actuation by the limb, related to the magnitude and direction of the ground reaction force (GRF) impulse, respectively. In most cases, the muscles of the limb either produced or absorbed energy during the response, as indicated by net changes in COM energy (Ecom). The limb likely begins stance in a more retracted, extended position due to the 26 ms delay in ground contact relative to that anticipated by the bird. This could explain the diminished decelerating force during the first half of stance and the exchange between EP and EK during stance as the body vaults over the limb. The varying degree of weight support and energy absorption in the perturbed step suggests that variation in the initial limb configuration leads to different intrinsic dynamics and reflex action. Future investigation into the limb and muscle mechanics underlying these responses could yield further insight into the control mechanisms that allow such robust dynamic stability of running in the face of large, unexpected perturbations.

Analysis of Variance↗

Imaging well-differentiated hepatocellular carcinoma with dynamic triple-phase helical computed tomography.

To investigate the imaging appearance of well-differentiated hepatocellular carcinoma (HCC) on dynamic CT, a total of 38 histopathologically proven well-differentiated HCC were included in a retrospective study. We reviewed the contrast-enhanced dynamic CT of all 38 tumours for attenuation of each tumour in unenhanced scan, arterial-dominant and delayed portal venous phases. Our results showed that dynamic CT identified 26 (68.4%) out of the 38 lesions. The remaining 12 lesions were isodense compared with surrounding liver parenchyma in each dynamic CT phase. There was no statistically significant difference between the mean size of tumours detected by dynamic CT and that of tumours not detected by dynamic CT (p = 0.1). Of a total of 38 tumours, most were isodense (n = 19) or hypodense (n = 16) in unenhanced scan, mostly hyperdense (n = 18) or isodense (n = 15) in arterial-dominant phase and mostly isodense (n = 22) or hypodense (n = 15) in delayed portal venous phase. Enhancement of tumour was observed in 19 (50.0%) of 38 lesions. In conclusion, the ability of dynamic CT to detect well-differentiated HCC is poor, and negative CT findings cannot exclude the presence of well-differentiated HCC, especially if there is well-grounded clinical suspicion for HCC.

Adult↗

"Dynamic" connectivity in neural systems: theoretical and empirical considerations.

The study of functional interdependences between brain regions is a rapidly growing focus of neuroscience research. This endeavor has been greatly facilitated by the appearance of a number of innovative methodologies for the examination of neurophysiological and neuroimaging data. The aim of this article is to present an overview of dynamical measures of interdependence and contrast these with statistical measures that have been more widely employed. We first review the motivation, conceptual basis, and experimental approach of dynamical measures of interdependence and their application to the study of neural systems. A consideration of boot-strap "surrogate data" techniques, which facilitate hypothesis testing of dynamical measures, is then used to clarify the difference between dynamical and statistical measures of interdependence. An overview of some of the most active research areas such as the study of the "synchronization manifold," dynamical interdependence in neurophysiology data and the putative role of nonlinear desynchronization is then given. We conclude by suggesting that techniques based on dynamical interdependence--or "dynamical connectivity"--show significant potential for extracting meaningful information from functional neuroimaging data.

Brain↗

Contrast sensitivity in a dynamic environment: effects of target conditions and visual impairment.

Contrast sensitivity was determined as a function of target velocity (0 degrees - 120 degrees/s) over a variety of viewing conditions. In Experiment 1, measurements of dynamic contrast sensitivity were determined for 24 male and 24 female observers as a function of target velocity for letter stimuli of 2 sizes and 2 durations. Significant main effects were found for target velocity, target size, and target duration, but significant interactions among the variables indicated especially pronounced adverse effects of increasing target velocity for small targets and brief durations. In Experiment 2, the effects of simulated cataracts on dynamic contrast sensitivity were determined for 10 male and 10 female observers. Although the simulated impairment had no effect on traditional acuity scores, dynamic contrast sensitivity was markedly reduced under all conditions but especially with the smaller targets and at higher velocities. Results are discussed in terms of dynamic contrast sensitivity as a useful composite measure of visual functioning that may provide a better overall picture of an individual's visual functioning than does traditional static acuity, dynamic acuity, or contrast sensitivity alone. The measure of dynamic contrast sensitivity may increase understanding of the practical effects of various conditions, such as aging or disease, on the visual system, or it may allow improved prediction of individuals' performance in visually dynamic, situations, such as driving and sports.

Adolescent↗

History-dependent multiple-time-scale dynamics in a single-neuron model.

History-dependent characteristic time scales in dynamics have been observed at several levels of organization in neural systems. Such dynamics can provide powerful means for computation and memory. At the level of the single neuron, several microscopic mechanisms, including ion channel kinetics, can support multiple-time-scale dynamics. How the temporally complex channel kinetics gives rise to dynamical properties of the neuron is not well understood. Here, we construct a model that captures some features of the connection between these two levels of organization. The model neuron exhibits history-dependent multiple-time-scale dynamics in several effects: first, after stimulation, the recovery time scale is related to the stimulation duration by a power-law scaling; second, temporal patterns of neural activity in response to ongoing stimulation are modulated over time; finally, the characteristic time scale for adaptation after a step change in stimulus depends on the duration of the preceding stimulus. All these effects have been observed experimentally and are not explained by current single-neuron models. The model neuron here presented is composed of an ensemble of ion channels that can wander in a large pool of degenerate inactive states and thus exhibits multiple-time-scale dynamics at the molecular level. Channel inactivation rate depends on recent neural activity, which in turn depends through modulations of the neural response function on the fraction of active channels. This construction produces a model that robustly exhibits nonexponential history-dependent dynamics, in qualitative agreement with experimental results.

Algorithms↗

Large-scale conformational dynamics of the HIV-1 integrase core domain and its catalytic loop mutants.

HIV-1 integrase is one of the three essential enzymes required for viral replication and has great potential as a novel target for anti-HIV drugs. Although tremendous efforts have been devoted to understanding this protein, the conformation of the catalytic core domain around the active site, particularly the catalytic loop overhanging the active site, is still not well characterized by experimental methods due to its high degree of flexibility. Recent studies have suggested that this conformational dynamics is directly correlated with enzymatic activity, but the details of this dynamics is not known. In this study, we conducted a series of extended-time molecular dynamics simulations and locally enhanced sampling simulations of the wild-type and three loop hinge mutants to investigate the conformational dynamics of the core domain. A combined total of >480 ns of simulation data was collected which allowed us to study the conformational changes that were not possible to observe in the previously reported short-time molecular dynamics simulations. Among the main findings are a major conformational change (>20 A) in the catalytic loop, which revealed a gatinglike dynamics, and a transient intraloop structure, which provided a rationale for the mutational effects of several residues on the loop including Q(148), P(145), and Y(143). Further, clustering analyses have identified seven major conformational states of the wild-type catalytic loop. Their implications for catalytic function and ligand interaction are discussed. The findings reported here provide a detailed view of the active site conformational dynamics and should be useful for structure-based inhibitor design for integrase.

Binding Sites↗

Measuring fast dynamics in solutions and cells with a laser scanning microscope.

Single-point fluorescence correlation spectroscopy (FCS) allows measurements of fast diffusion and dynamic processes in the microsecond-to-millisecond time range. For measurements on living cells, image correlation spectroscopy (ICS) and temporal ICS extend the FCS approach to diffusion times as long as seconds to minutes and simultaneously provide spatially resolved dynamic information. However, ICS is limited to very slow dynamics due to the frame acquisition rate. Here we develop novel extensions to ICS that probe spatial correlations in previously inaccessible temporal windows. We show that using standard laser confocal imaging techniques (raster-scan mode) not only can we reach the temporal scales of single-point FCS, but also have the advantages of ICS in providing spatial information. This novel method, called raster image correlation spectroscopy (RICS), rapidly measures during the scan many focal points within the cell providing the same concentration and dynamic information of FCS as well as information on the spatial correlation between points along the scanning path. Longer time dynamics are recovered from the information in successive lines and frames. We exploit the hidden time structure of the scan method in which adjacent pixels are a few microseconds apart thereby accurately measuring dynamic processes such as molecular diffusion in the microseconds-to-seconds timescale. In conjunction with simulated data, we show that a wide range of diffusion coefficients and concentrations can be measured by RICS. We used RICS to determine for the first time spatially resolved diffusions of paxillin-EGFP stably expressed in CHOK1 cells. This new type of data analysis has a broad application in biology and it provides a powerful tool for measuring fast as well as slower dynamic processes in cellular systems using any standard laser confocal microscope.

Algorithms↗

Using photoinduced charge transfer reactions to study conformational dynamics of biopolymers at the single-molecule level.

This mini-review describes how single-molecule sensitive fluorescence resonance energy transfer (FRET) and photoinduced electron transfer (PET) reactions can be successfully applied to monitor conformational dynamics in biopolymers. Single-pair FRET experiments are ideally suited to study conformational dynamics occurring on the nanometer scale, e.g. during protein folding or unfolding. In contrast, conformational dynamics with functional significance, for example occurring in enzymes at work, often appear on much smaller spatial scales of up to several Angströms. Our results demonstrate that selective PET-reactions between fluorophores and amino acids or DNA nucleotides represent a versatile tool to measure small-scale conformational dynamics in biopolymers on a wide range of time scales, extending from nanoseconds to seconds, at the single-molecule level. That is, the monitoring of conformational dynamics of biopolymers with temporal resolutions comparable to those within reach using new techniques of molecular dynamic simulations. Furthermore, we demonstrate that the strong distance dependence of charge separation reactions on the sub-nanometer scale can be used to develop conformationally flexible PET-biosensors. These sensors enable the detection of specific target molecules in the sub-picomolar range and allow one to follow their molecular binding dynamics with temporal resolution.

Biopolymers↗

Preoperative assessment of gastric carcinoma: value of two-phase dynamic CT with mechanical iv. injection of contrast material.

OBJECTIVE: The purpose of this study was to evaluate the utility of two-phase dynamic CT performed with mechanical IV injection of a bolus of contrast medium after oral intake of water in the preoperative staging of gastric cancers. SUBJECTS AND METHODS: We performed incremental dynamic CT in 52 patients with pathologically proved gastric cancers. Dynamic CT findings were prospectively analyzed and correlated with surgical and histopathologic findings. A total of 150 ml of nonionic contrast medium was administered IV with a power injector at a flow rate of 5 ml/sec for 30 sec, and two-phase images were obtained at 30 sec (early phase) and 2 min (equilibrium phase) after the start of bolus injection. RESULTS: Forty-one advanced gastric carcinomas showed a moderate to marked degree of heterogeneous enhancement in the early phase and homogeneous enhancement of the entire lesion in the equilibrium phase of dynamic CT. The primary tumors were correctly detected with dynamic CT in five (56%) of the nine early gastric cancers and in 41 (95%) of the 43 advanced gastric cancers. The overall detection rate of gastric cancers was 88% (46 of 52 cases). The accuracies of dynamic CT according to TNM staging in determining the depth of tumor invasion, the degree of serosal invasion, and regional lymph node metastasis were 65% (34 of 52 cases), 83% (38 of 46 cases), and 70% (32 of 46 cases), respectively. CONCLUSION: Our findings show that two-phase incremental dynamic CT with mechanical IV injection of a bolus of contrast medium after oral intake of water improves the diagnostic accuracy of CT over that provided by conventional CT in the preoperative staging of gastric cancers.

Adult↗

Detection of pituitary microadenomas: comparison of dynamic keyhole fast spin-echo, unenhanced, and conventional contrast-enhanced MR imaging.

OBJECTIVE: Pituitary microadenomas may not be detected on conventional MR images. We supplemented conventional unenhanced and contrast-enhanced MR imaging with a dynamic keyhole fast spin-echo (kFSE) method in order to compare how frequently a microadenoma could be detected with the three different methods. SUBJECTS AND METHODS: Eighteen consecutive patients with clinical and laboratory evidence of pituitary microadenomas had unenhanced, dynamic kFSE, and conventional contrast-enhanced MR imaging of the pituitary gland. A control group of 13 subjects without pituitary disease also had dynamic kFSE MR imaging. Hard copies of all the studies were obtained in an identical fashion, and then the MR images of the patients and control subjects were randomly mixed. The studies were reviewed by a neuroradiologist who had no knowledge of the clinical status of the subjects. The presence or absence of any pituitary focal hypointensity consistent with the appearance of a microadenoma was noted. RESULTS: A pituitary lesion consistent in appearance with a microadenoma was detected on dynamic kFSE images in 13 of the 18 patients, on unenhanced images in nine patients, and on conventional contrast-enhanced images in 10 patients. In four patients, a microadenoma was detected on dynamic kFSE images only. Dynamic kFSE images showed a lesion in four of the 13 control subjects. CONCLUSION: Dynamic kFSE MR imaging is a useful supplemental sequence in patients undergoing MR imaging because of pituitary endocrinopathy. It may show lesions that would otherwise escape detection.

Adenoma↗

Osteosarcoma and Ewing's sarcoma after neoadjuvant chemotherapy: value of dynamic MR imaging in detecting viable tumor before surgery.

OBJECTIVE: This study analyzed the value of dynamic contrast-enhanced and subtraction MR images in detecting residual viable tumor before surgery, with emphasis on timing of enhancement, in patients with high-grade osteosarcoma and Ewing's sarcoma after neoadjuvant chemotherapy. SUBJECTS AND METHODS: Twenty-one patients with proved osteosarcoma or Ewing's sarcoma were treated with neoadjuvant chemotherapy followed by surgery. After IV administration of gadopentetate dimeglumine, dynamic enhancement patterns on preoperative MR images were compared with corresponding areas on histologic sections of the resected specimens. On dynamic subtraction images obtained with high temporal resolution (1.5-3 sec), the interval between arrival of the bolus of contrast agent in an artery and start of tumoral enhancement was used to distinguish residual viable tumor. Early enhancing foci (interval artery-tumor < 6 sec) and late or nonenhancing areas seen on MR images were correlated with the histopathologic findings in these areas of the resected specimens. RESULTS: Early and progressively enhancing structures seen on MR images corresponded to feeding arteries, physeal vessels, or residual viable tumor at specific preferential sites on corresponding histologic sections of the resected specimens. Tumor foci as small as 3-5 mm2 could be detected on dynamic MR images. Remnant viable tumor was often located subperiosteally and at the margins of the tumor. Occasionally, active periosteal reaction without presence of viable tumor contributed to early enhancement. Late and gradually enhancing or nonenhancing areas corresponded histopathologically to regions of chemotherapy-induced necrosis, mucomyxoid degeneration, or fibrosis. Alternatively, late or nonenhancing areas were associated with reactive changes such as edema, hemorrhage, or osteomyelitis or with tumor-related extracellular matrices such as abundant osteoid or chondroid. Viable tumor areas with scarce formation of matrix on microscopy, such as small cell osteosarcoma areas or Ewing's sarcoma, showed early enhancement with rapid washout of contrast agent on the dynamic MR images. CONCLUSION: Fast dynamic contrast-enhanced sequences are essential for identifying residual tumor before surgery. A short time interval of less than 6 sec between arterial enhancement and tumoral enhancement strongly correlates with presence of viable tumor. Both therapy-related alterations of tissue and tumor-related matrices must be considered when late or lack of enhancement is noted on dynamic MR images.

Adolescent↗

Quantitative evaluation of mean transit times obtained with dynamic susceptibility contrast-enhanced MR imaging and with (133)Xe SPECT in occlusive cerebrovascular disease.

OBJECTIVE: We report on quantitative mean transit time images obtained using dynamic susceptibility contrast-enhanced MR imaging after an IV bolus injection of a contrast agent. Our study compared cerebral hemodynamics measured using dynamic susceptibility contrast-enhanced MR imaging with the cerebral perfusion reserve obtained using dynamic (133)Xe single-photon emission computed tomography (SPECT). SUBJECTS AND METHODS: Seventeen patients with chronic cerebral artery occlusion or stenosis diagnosed by digital subtraction angiography were examined. Dynamic susceptibility contrast-enhanced MR imaging data were acquired using a multishot echoplanar sequence. Our procedure for quantification of mean transit time was based on the indicator dilution theory and deconvolution analysis. RESULTS: The increased mean transit time values obtained with dynamic susceptibility contrast-enhanced MR imaging correlated well (r=-0.789, p < 0.0001) with decreased cerebral perfusion reserve determined by performing dynamic (133)Xe SPECT before and after administration of acetazolamide. The mean transit time values in the regions with severely decreased perfusion reserve were significantly higher than those in the regions with normal or moderately decreased perfusion reserve (p < 0.0001 and p = 0.0004, respectively). CONCLUSION: Mean transit time images generated from dynamic susceptibility contrast-enhanced MR imaging data could be used to evaluate the extent of cerebral perfusion reserve impairment in patients with occlusive cerebrovascular disease.

Aged↗

Mental rotation of static and dynamic figures.

Previous studies comparing performance on standard (i.e., static) and dynamic spatial test items have concluded that the two item types measure different abilities. Such conclusions about the uniqueness of static and dynamic spatial abilities seem premature, however, since only a limited number of dynamic spatial tasks have been utilized in research and these have differed markedly from their static counterparts. In the present studies, tasks were designed to require a common mental operation (mental rotation) under static and dynamic conditions. Correlations between static and dynamic performance ranged from .80 to .90. This appears to suggest that the emergence of a unique dynamic ability factor depends on the utilization of certain specialized tasks (e.g., arrival time tasks) with mental operations much different than those required by conventional spatial tests. In other words, it is apparently the requirement for different cognitive processes and not the processing of stimulus motion per se that distinguishes performance on some dynamic tasks from performance on some standard static tasks.

Adult↗

Dynamic left ventricular outflow tract obstruction in acute coronary syndromes: an important cause of new systolic murmur and cardiogenic shock.

Dynamic left ventricular outflow tract (LVOT) obstruction has traditionally been associated with hypertrophic obstructive cardiomyopathy. Recently, acute dynamic LVOT obstruction has been described as a complication of myocardial infarction (MI). Herein the cases of 3 patients are described, all of whom presented with a systolic murmur and electrocardiographic evidence of MI. All 3 patients developed cardiogenic shock and were subsequently found by echocardiography to manifest an acute dynamic LVOT obstruction. Cardiogenic shock persisted until therapy was directed toward decreasing the degree of the dynamic LVOT obstruction. The treatment of acute coronary syndromes in the presence of a dynamic LVOT obstruction differs from the traditional treatment of acute coronary syndromes and includes the use of beta-blockers and alpha1-agonists, as well as the avoidance of therapies that aggravate the magnitude of the LVOT obstructive gradient, including nitrates, inotropic agents, and afterload reduction. The development of a systolic murmur in the setting of acute MI complicated by cardiogenic shock with only a small elevation in creatine kinase suggests the presence of a dynamic LVOT obstruction, as well as the classical mechanical complications of MI, namely, ventricular septal rupture and papillary muscle rupture. The presence of a dynamic LVOT obstruction is reliably detected by transthoracic echocardiography or by transesophageal echocardiography if transthoracic image quality is suboptimal.

Aged↗

Age-based differences between mercury sphygmomanometer and pulse dynamic blood pressure measurements.

BACKGROUND: Both the mercury sphygmomanometer and oscillometric measurement methods are widely in use for pediatric, adult, and geriatric patients. However, inherent differences between the methods of measurement may create varying degrees of sensitivity to age and potentially result in differences between measurements for these two techniques. DESIGN: Measurements of systolic and diastolic blood pressures in 154 subjects were obtained using the mercury sphygmomanometer and pulse dynamic oscillometric methods in accordance with the 1987 Association for the Advancement of Medical Instrumentation guidelines. Subjects were separated into three age groups and their data analyzed for differences between measurements for these two techniques. METHODS: Two qualified nurses derived systolic and diastolic blood pressures using phase I and phase IV Korotkoff sounds, respectively, during simultaneous monitoring with the pulse dynamic oscillometric method. RESULTS: Inter-nurse variabilities for measurement derived by mercury sphygmomanometer were 1.8 +/- 4.1 for systolic and 0.9 +/- 3.9for diastolic blood pressure. Mean differences (reference-device) of -5 +/- 5 mmHg (pulse dynamic value higher) for systolic and 1 +/- 5 mmHg (pulse dynamic value lower) for diastolic blood pressure between pulse dynamic and mercury sphygmomanometer values were found for all subjects. However, pulse dynamic systolic blood pressure was significantly higher than mercury sphygmomanometer systolic blood pressure for group 1 (n = 51, aged 11-22 years, mean difference -5.6 mmHg, P = 0.03). A similar trend was observed with group 2 (n = 51, aged 23-54 years, mean difference -4.3 mmHg, P = 0.06). We observedf no significant difference for systolic blood pressure with group 3 (n = 52, aged 55-85 years, mean difference -3.8 mmHg, P > 0.1). For all three groups we found no significant difference for diastolic blood pressure. CONCLUSION: The variation in the agreement of systolic blood pressure measurements can be attributed to the differing effects of age-dependent arterial changes on the measurement methods. The findings indicate that, although the pulse dynamic oscillometric method and mercury sphygmomanometer correlate well when patients of all ages were evaluated as a group, agreement between measurements of systolic blood pressure is dependent on age and the method of measurement employed.

Journal Article↗

[Cerebrospinal fluid flow dynamics in cerebral infarction--Numerical study with RI Anger camera (author's transl)].

Although the cerebral blood flow dynamics in cerebral infarction has already been studied by many investigators, the CSF flow dynamics in cerebral infarction has not been well discussed. The purpose of this paper is to investigate CSF flow dynamics in chronic cerebral infarction by RI cisternography and our new quantitative method. In 12 patients with cerebral infarction, the flow of CSF was estimated following intrathecal injection of 169Yb-DTPA or 111In-DTPA. In this study, in addition to the conventional cisternograms, quantitative evaluation of CSF flow was performed in 6 patients by our method. Our previous work included the quantitative CSF flow dynamics in 26 various cerebral disorders using RI Anger camera. This method consisted of following procedure: 30 minutes after RI injection, RI activity was studied continuously for 30 minutes, afterwards playing back the record to calculate the changes of RI activity in the optimal regions of interest. These operations were performed with Anger camera, accessory digital ratemeter and tape-recorder. The changes of RI activity which appeared to be linear is called flow rate in our study for convenience. In this report, the region of interest was selected at Sylvian cistern. 6 patients had abnormal cisternograms consisting of reflux of tracer into the ventricle and delayed migration of tracer to the basal cisterns and diminished flow of tracer in the affected hemisphers. In 5 patients whose cisternograms could not demonstrate the laterality of RI perfsion over the cerebral hemishere, a marked difference of flow rate between right and left Sylvian cisterns was found. These findings probably indicated the correlation between cerebral blood flow dynamics and CSF flow dynamics in cerebral infarction. Moreover, it was confirmed that our method could be of clinical use to evaluate CSF flow dynamics quantitatively. The possible mechanisms of CSF flow disturbance in the affected hemisphere following cerebral infarction was discussed.

Adult↗

Dynamic helical biphasic CT emerges as a potential tool for the diagnosis of proximal arterioportal shunting.

BACKGROUND/AIMS: This article reports our preliminary observation regarding the diagnostic ability of dynamic helical biphasic computed tomography (CT) for proximal arterioportal shunting in hepatoma patients as compared with that of conventional angiography. METHODOLOGY: Three hundred and sixty patients with clinically-suspected liver lesions received both dynamic helical biphasic CT scan and conventional angiography of the liver. The criteria for diagnosis of proximal arterioportal (AP) shunting in dynamic helical biphasic CT included early and strong enhancement of main portal vein or its major branches approaching the density of the aorta, or enhancement of the portal vein earlier than opacification of the splenic vein and superior mesenteric vein in the arterial phase. The angiographic diagnosis of proximal AP shunting was made if there was early opacification of the main portal vein or its major branches in the arterial phase. Peripheral subsegmental small AP shunting was excluded from our study. The existence and extent of AP shunting were compared in these two imaging modalities. RESULTS: Dynamic helical biphasic CT scan demonstrated proximal AP shunting in 23 patients. All of these patients harbored hepatoma. Conventional angiography showed proximal AP shunting in 20 patients, which were all positive on dynamic helical CT. Dynamic helical biphasic CT demonstrated the presence of proximal AP shunting in 3 more patients than conventional angiography did. The extent of AP shunting was well correlated between these two imaging modalities in 17 patients. CONCLUSIONS: From our preliminary experience, the diagnostic accuracy of dynamic helical biphasic CT for proximal AP shunting in patients with hepatoma seemed to be comparable to, or even surpassed that of conventional angiography. It seems that faint AP shunting in patients with large hepatoma might be missed by conventional angiography.

Adult↗

State-dependency of neuronal slow dynamics during sleep observed in cat lateral geniculate nucleus.

From the accumulated results, we hypothesize that neurons in the central processor systems of the brain generally exhibit a common state-dependency in slow dynamics of their spontaneous activities during sleep. In this paper, activities of relay cells in the cat's lateral geniculate nucleus (LGN) were studied to see if our hypothesis can be applied in this thalamic region. Data segments in polygraphically steady states were strictly extracted in order to sample the activities whose stationarity was guaranteed in a statistical sense. During slow wave sleep (SWS), the discharge pattern was characterized by short bursts. In contrast, the rather tonic discharge pattern was observed to prevail during rapid eye movement (REM) sleep. Spectral analyses showed white noise-like spectra in the low frequency range of 0.04-1.0 Hz during SWS, and 1/f noise-like spectra in the same frequency range during REM sleep. This state-dependency of the slow dynamics was consistently characterized by the other statistical parameters concerning the second-order moment as well. In contrast, the fast dynamics over 1.0 Hz tended to exhibit neuron-specific changes associated with the sleep state in terms of the Markovian dependency analysis. Consequently, our working hypothesis was not rejected for the LGN relay cells. The result here extends the possibility that the state-dependency of the slow dynamics we found is a general rule concerning single neuronal dynamics in widespread areas of the brain during sleep. The state-dependency of the slow dynamics of the LGN relay cells could be understood according to the proposed mechanism that a state-associated alteration in the global biasing input to a neural network during sleep induces the phenomenon with which we are concerned. The slow dynamics of neuronal activities might provide a novel framework defining SWS and REM sleep states instead of the polygraphic characteristics.

Animals↗